Features
■ Superior circuit protection
■ Overcurrent and overvoltage protection
■ Blocks surges up to rated limits
■ High-speed performance
■ Small SMT package
■ RoHS compliant*
■ Agency recognition:
Applications
■ Voice / VDSL cards
■ Protection modules and dongles
■ Process control equipment
■ Test and measurement equipment
■ General electronics
TBU-CX Series - TBU® High-Speed Protectors
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
General Information
The TBU-CX Series of Bourns® TBU®
products are low capacitance dual bidirec-
tional high-speed protection components,
constructed using MOSFET semiconductor
technology, and designed to protect against
faults caused by short circuits, AC power cross,
induction and lightning surges.
The TBU® high-speed protector placed in the system circuit will monitor the current with
the MOSFET detection circuit triggering to provide an effective barrier behind which
sensitive electronics will not be exposed to large voltages or currents during surge
events. The TBU® device is provided in a surface mount DFN package and meets
industry standard requirements such as RoHS and Pb Free solder refl ow profi les.
Agency Approval
Description
UL File Number: E315805
Absolute Maximum Ratings (@ TA = 25 °C Unless Otherwise Noted)
Symbol Parameter Part Number Value Unit
Vimp Peak impulse voltage withstand with duration less than 10 ms
TBU-CX025-VTC-WH
TBU-CX040-VTC-WH
TBU-CX050-VTC-WH
TBU-CX065-VTC-WH
TBU-CX085-VTC-WH
250
400
500
650
850
V
Vrms Continuous A.C. RMS voltage
TBU-CX025-VTC-WH
TBU-CX040-VTC-WH
TBU-CX050-VTC-WH
TBU-CX065-VTC-WH
TBU-CX085-VTC-WH
100
200
250
300
425
V
Top Operating temperature range -40 to +125 °C
Tstg Storage temperature range -65 to +150 °C
Tjmax Maximum Junction Temperature +125 °C
ESD HBM ESD Protection per IEC 61000-4-2 ±2 kV
External Resistor
Line In/
Line Out
Line Out/
Line In
R
Electrical Characteristics (@ TA = 25 °C Unless Otherwise Noted)
Symbol Parameter Part Number Min. Typ. Max. Unit
Itrigger
Current required for the device to go from operating state to
protected state (Rexternal = 0 ohm) TBU-CXxxx-VTC-WH 500 750 1000 mA
Rdevice
Series resistance of
the TBU device
(Rexternal = 0 ohm)
Vimp = 250 V Itrigger (min.) = 500 mA
Vimp = 400 V Itrigger (min.) = 500 mA
Vimp = 500 V Itrigger (min.) = 500 mA
Vimp = 650 V Itrigger (min.) = 500 mA
Vimp = 850 V Itrigger (min.) = 500 mA
TBU-CX025-VTC-WH
TBU-CX040-VTC-WH
TBU-CX050-VTC-WH
TBU-CX065-VTC-WH
TBU-CX085-VTC-WH
2.6
3.6
5.0
7.0
10.7
3.0
4.2
5.7
8.0
13.0
Ω
tblock Time for the device to go from normal operating state to protected state 1 µs
IQCurrent through the triggered TBU® device with 50 Vdc circuit voltage 0.25 0.50 1.00 mA
Vreset Voltage below which the triggered TBU® device will transition to normal operating state 12 16 20 V
Rth(j-l) Junction to package pads - FR4 using recommended pad layout 98 °C/W
Rth(j-l) Junction to package pads - FR4 using heat sink on board (6 cm2) (1 in2) 40 °C/W
*RoHS COMPLIANT
CX85
0075