Cell size references (AA )
Electrical characteristics
(typical values relative to cells stored for one year or less at +30 max.)
Nominal capacity 2.4Ah
(at 1 mA +20 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
Open circuit voltage (at +20 ) 3.66V
Nominal voltage (at 1mA +20 ) 3.6V
Pulse capability: Typically up to 200 mA (200 mA/0.1 second pulses,
drained every 2 mn at +20 from undischarged cells with 10 A base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell s previous history.
Fitting the cell with a capacitor may be recommended in severe conditions.
Consult pbq)
Max. Continuous current 100mA
Max. Pulse current 200mA
Storage (recommended) +30 max
(for more severe conditions, consult pbq)
Operating temperature range -55 / +85
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult pbq)
Physical characteristics
Diameter (max) 14.5mm(0.55 in)
Height (max) 50.5mm(2 in)
Typical weight 19g(0.622oz)
Available termination suffix radial tabs, radial pins, axial leads, flying leads
LITHIUM BATTERY
Primary lithium batteries
ER14505
3.6V Primary lithium-thionyl chloride
(Li-SOCl2) Energy type
AA-size bobbin cell For low drain / long time
applications requesting superior
voltage response in -55 ~+85
environments.
R
R
www.pbq-batteries.com
ER14505
Hours
Voltage V
Voltage V
Voltage VS Temperature
Capacity VS Current
Capacity Ah
Temperature
Current mA
Unit:mm
(+)
6 0.1
11 0.2
0.4
10 0.2
1 0.05
LITHIUM BATTERY
Discharge performance 25
Characteristic curves
14.5Max
51Max
3.8
3.6
3.4
3.2
3.0
2.8
-60-40-20020406080
10 A
0.2mA
1mA
5mA
2.2.
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
2.4
0.010.1110100
72
33
100
330
3.5k
18k
100mA
33mA
10mA
1mA
200
A
0.8Ah
1.3Ah
1
.
9
Ah
2.4Ah
2.3Ah
3.5
3.0
2.5
2.0
1.5
1.0
0.111010101010
2345
4.0
3.5
3.0
2
.5
2
.0
012345678910
(Second)
55
20
0
-30
R
www.pbq-batteries.com
Key features
High and stable operating voltage
Superior drain capability
Low self-discharge rate
(less than 1% after 1year of storage
at +20 )
Hermetic glass-to-metal sealing
Notch technology for safety vent is
recommended
Non-flammable electrolyte
Main applications
Radiocommunication and other
military applications
Alarms and security systems
Beacons and emergency location
transmitters
GPS
Metering systems
Sonobuoys
LED lighting applications
Others
Storage
The storage area should be clean,
cool (not exceeding +30 ), dry
and ventilated.
Warning
Do not use if the battery casing was
mangled.
Don t use different models of battery
in series.
Do not try to recharge.