AC Line Filters Common Mode SCR Coils, 31 Series Overview Applications The KEMET SCR coils are common mode chokes with a wide variety of characteristics. These toroidal coils are designed with our proprietary high permeability ferrite S15H cores and are useful in various noise countermeasure fields. * Audio-visual equipment * Home appliances * Power supplies Benefits * * * * * * Proprietary S15H ferrite material High permeability High impedance Space saving due to high permeability material Operating temperature range from -25C to +120C UL94 V-0 flame retardant rated base and cap Part Number System SCR 38- 130- S 1R4 A 015 J Series Dimension Code (See Dimensions) Rated Current AC (A) Phase Wire Diameter (mm) Windings Inductance (mH) Minimum Terminal Base Type SCR Blank 22 25 25B 31B 38 38C 47 47B xxx- = xx.x A Examples: 050 = 5.0 A 350 = 35.0 A 105 = 10.5 A Blank = Single-phase S = Three-phase R = Decimal point Examples: 0R55 = 0.55 mm 1R4 = 1.4 mm A = Single B = Double C = Triple xxx = xx.xmH J = Vertical type JH = Horizontal type Examples: 015 = 1.5 mH 100 = 10 mH Note: With exceptions, see Table 1 for details. One world. One KEMET (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com LF0055_SCR31 * 11/26/2018 1 AC Line Filters - Common Mode SCR Coils, 31 Series Magnetic Permeability of Ferrite Material In order to achieve most efficient noise reduction, it is important to select the material according to the target frequency band.Depending on its magnetic permeability, a particular ferrite material will be effective in a certain frequency band. A schematic representation of the relationship between the magnetic permeability of each material and the corresponding effective band range is shown in Figure 1. Materials with higher magnetic permeability are effective in the lower frequency range, while those with lower magnetic permeability are effective in the higher frequency range. Thus, Mn-Zn products are mainly used for reducing conduction noise, while Ni-Zn products are commonly used for radiation noise countermeasures. The effective frequency range varies depending on core shape, size and number of windings. This frequency dependence of the magnetic permeability as shown in the figure serves for reference purposes only and it should be tested on the actual device to determine its effectiveness. S18H, S15H, 10H, 7H, 5H, 1400L and 700L are KEMET's proprietary ferrite material names. Other materials can also be available on request. Figure 1 - Relationship between the magnetic permeability of each material and its effective frequency range 20,000 Higher magnetic permeability: Higher noise suppression effect in the lower frequency range Mn-Zn Series Magnetic Permeability S18H S15H 10H 10,000 Lower magnetic permeability: Higher noise suppression effect in the higher frequency range 7H 5H Ni-Zn Series 0 10 kHz 1400L 700L 100 kHz 1 MHz 10 MHz 100 MHz 1 GHz Effective Frequency Range (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com LF0055_SCR31 * 11/26/2018 2 AC Line Filters - Common Mode SCR Coils, 31 Series Dimensions - Millimeters 48 Maximum 35 Maximum 4 1* 42 Maximum Marking Adhesive 2points Solder plating Sn-0.75Cu 4 N1 N2 2 3 (30) (17) 1 *Reference value. Environmental Compliance All KEMET AC line filters are RoHS Compliant. Table 1 - Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (mH) Minimum DC Resistance/ Line (m) Maximum Temperature Rise (K) Maximum Wire Diameter (mm) Weight (g) Approximate SCR31B-105-1R4A055JH SCR31B-200-1R9A017JH 10.5 20.0 5.5 1.7 22.0 6.3 80 79 1.4 1.9 84 87 (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com LF0055_SCR31 * 11/26/2018 3 AC Line Filters - Common Mode SCR Coils, 31 Series Performance Characteristics Item Rated Voltage Withstanding Voltage Insulation Resistance Rated Current AC Range Rated Inductance Range Inductance Measurement Condition Thermal Class Operating Temperature Range Performance Characteristics 500 VAC/VDC 2,400 VAC (2 seconds, between lines) > 100 M at 500 VDC (between lines) 10.5 - 20.0 A 1.7 - 5.5 mH minimum 10 kHz E (120C) -25C to +120C (include self temperature rise) Frequency Characteristics Packaging Type Packaging Type Pieces Per Box SCR31-JH Tray 80 (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com LF0055_SCR31 * 11/26/2018 4 AC Line Filters - Common Mode SCR Coils, 31 Series Handling Precautions Precautions for product storage AC Line Filters should be stored in normal working environments. While the chokes themselves are quite robust in other environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres, and long term storage. KEMET recommends that maximum storage temperature not exceed 40C and maximum storage humidity not exceed 70% relative humidity. Atmospheres should be free of chlorine and sulfur bearing compounds. Temperature fluctuations should be minimized to avoid condensation on the parts. Avoid storage near strong magnetic fields, as this might magnetize the product. For optimized solderability, AC line filters stock should be used promptly and preferably within 6 months of receipt. Product temperature rise values The values listed for temperature rise are the result of self-heating in wires when the rated current (commercial frequency) is applied. When using the product, check and evaluate the value of the core temperature rise under actual operating conditions. Export Control For customers in Japan For products that are controlled items subject to the "Foreign Exchange and Foreign Trade Law" of Japan, the export license specified by the law is required for export. For customers outside Japan AC line filters should not be used or sold for the use in the development, production, stockpiling, or utilization of any conventional weapons, mass-destruction weapons (nuclear, chemical, biological weapons, or missiles), or any other weapons. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com LF0055_SCR31 * 11/26/2018 5 AC Line Filters - Common Mode SCR Coils, 31 Series KEMET Electronics Corporation Sales Offices For a complete list of our global sales offices, please visit www.kemet.com/sales. Disclaimer All product specifications, statements, information and data (collectively, the "Information") in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation's ("KEMET") knowledge of typical operating conditions for such applications, but are not intended to constitute - and KEMET specifically disclaims - any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET's products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. KEMET is a registered trademark of KEMET Electronics Corporation. (c) KEMET Electronics Corporation * KEMET Tower * One East Broward Boulevard Fort Lauderdale, FL 33301 USA * 954-766-2800 * www.kemet.com LF0055_SCR31 * 11/26/2018 6