DATA SHEET CITILED COB Series Standard Type Ra70,80 Model CLU038-1206C4 Introduction P 2 Performance Characteristics P 3 Mechanical Dimensions P 5 Characteristic Curves P 6 Reliability P 9 Packing Specification P 10 Precaution P 11 1 Ref.CE-P3524 02/16 Product Nomenclature CLU038 - 12 06 C4 - 27 3 M2 K1 [1] [2] [3] [4] [1] Product shape CLU038 [2] Die count in series 12 [3] Die count in parallel 06 [4] Nominal CCT 2700K [5] CRI (Ra) Min.80 [5] 1. Introduction 1-1. Product Description CITIZEN ELECTRONICS is the first COB manufacture. Our advanced knowledge and packaging technology for many years has excellent reliability and high quality of our products. CITILED COB Series covers a wide range of luminous flux from a 10W incandescent bulb to a 500W mercury lamp in general lighting sources. The element arrangement of LED package is capable of utilizing light more effectively and higher performance. The new version of CITILED COB Series succeed to reduce the thermal resistance significantly. New version creates more options to match luminaire's products design (ex. High performance , Cost effective , Higher lumen density , Increased allowable max. If). The outline and LES size is same since version 1. 3-step MacAdam ellipse color definition at Tj=85 is available. 1-2. Features 2 Ref.CE-P3524 02/16 2. Performance Characteristics 2-1. Electro Optical Characteristics ( Tj=85C ) Product code Nominal CCT CLU038-1206C4-273M2K1 2700K CLU038-1206C4-303M2K1 Luminous flux ( lm ) CRI T=85C Efficacy Forward ( lm/W ) Current Tc=25C* ( mA ) Typ. Typ. Voltage ( V) Thermal Resistance Rj-c ( C/W ) Ra R9 Min. Min. Min. Typ. Min. Typ. Max. 80 0 2,310 2,625 2,886 140 540 31.8 34.6 37.5 0.64 3000K 80 0 2,412 2,742 3,015 147 540 31.8 34.6 37.5 0.64 CLU038-1206C4-353M2K1 3500K 80 0 2,462 2,798 3,076 150 540 31.8 34.6 37.5 0.64 CLU038-1206C4-403M2K1 4000K 80 0 2,487 2,827 3,108 151 540 31.8 34.6 37.5 0.64 CLU038-1206C4-503M2K1 5000K 80 0 2,522 2,867 3,152 153 540 31.8 34.6 37.5 0.64 CLU038-1206C4-653M2K1 6500K 80 0 2,568 2,919 3,209 156 540 31.8 34.6 37.5 0.64 CLU038-1206C4-30AL7K3 3000K 70 - 2,549 2,897 3,185 155 540 31.8 34.6 37.5 0.64 CLU038-1206C4-40AL7K3 4000K 70 - 2,632 2,992 3,289 160 540 31.8 34.6 37.5 0.64 CLU038-1206C4-50AL7K3 5000K 70 - 2,673 3,038 3,340 162 540 31.8 34.6 37.5 0.64 Notes : 1. Citizen Electronics maintains forward voltage +/-3%, luminous flux +/-10%,Ra and R9 +/-1. *Values of Luminous flux at Tc=25C are provided as reference only. 2-2. Absolute Maximum Ratings Absolute Maximum Ratings Parameter Symbol Rating Input Power (W) Forward Current (mA) Reverse Current (mA) Operating Temperature (C) Storage Temperature (C) Case Temperature (C) Junction Temperature (C) Pi If Ir Top Tst Tc Tj 58.8 *1 1380 *1 1 -40 ~ +100 -40 ~ +100 105 *2 140 *3 *1. Input power and forward current are the values when the LED is used within the range of the derating curve in this data sheet. *2. Refer to 3. Outline drawing for Tc measurement point. *3. D.C. Current : Tj = Tc + Rj-c x Pi 3 Ref.CE-P3524 02/16 2-3. Chromaticity Characteristics ( Rated current, Tj=85C ) Oval parameter Color Region 3-step MacAdam ellipse Color Region ANSI C78. 377:2011 Nominal CCT Center Point ( x, y ) 2700K Major Axis a Minor Axis b ( 0.4577 , 0.4098 ) 0.00774 0.00411 Ellipse Rotation Angle 57.28 3000K ( 0.4339 , 0.4032 ) 0.00834 0.00408 53.17 3500K ( 0.4078 , 0.3929 ) 0.00951 0.00417 52.97 4000K ( 0.3818 , 0.3796 ) 0.00939 0.00402 54.00 5000K ( 0.3446 , 0.3551 ) 0.00822 0.00354 59.62 6500K ( 0.3123 , 0.3283 ) 0.00669 0.00285 58.38 Nominal CCT Center Point ( x, y ) 3000K ( 0.4339 , 0.4032 ) 0.4561 0.4259 0.4302 0.4171 0.4149 0.3820 0.4373 0.3892 4000K ( 0.3818 , 0.3796 ) 0.4003 0.4034 0.3737 0.3879 0.3671 0.3583 0.3895 0.3708 5000K ( 0.3446 , 0.3551 ) 0.3550 0.3752 0.3375 0.3619 0.3366 0.3372 0.3514 0.3480 ANSI parameter a ( x, y ) b ( x, y ) c ( x, y ) d ( x, y ) * Color region stay within MacAdam 3-step ellipse from the chromaticity center. * The chromaticity center refers to ANSI C78.377:2011. Please refer to ANSI C78. 377 for the chromaticity center. * is the angle between the major axis of the ellipse and the x-axis, and a and b are the major and minor semi-axes of an ellipse. (Ref. IEC 60081:1997 AnnexD) x-y chart CIE1931 0.45 3,000K 2,700K 3,500K Black Body Locus 4,000K 0.40 y 5,000K 0.35 6,500K ANSI 3-step 0.30 0.30 0.35 0.40 x 0.45 0.50 Note : Citizen Electronics maintains chromaticity ( x, y ) +/-0.005 4 Ref.CE-P3524 02/16 3. Mechanical Dimensions Internal Circuit Marking 1 : Serial No. Marking 2 : H 12 06 ** ** Protection device Anode CRI Cathode CCT Dies count in parallel LED device Dies count in series 12 s 06 p 5 Ref.CE-P3524 02/16 4. Characteristic Curves 4-1. Forward Current Characteristics / Temperature Characteristics Forward Current vs. Forward Voltage Forward Current vs. Relative Luminous Flux Tc=25C 40.0 Vf [V] Tc=25C 250% Relative Luminous Flux [a.u.] 42.0 38.0 36.0 34.0 32.0 30.0 200% 150% 100% 50% 0% 0 500 1000 1500 0 500 If [mA] Case Temperature vs. Forward Voltage 1500 Case Temperature vs. Relative Luminous Flux If=540mA If=540mA 120% Relative Luminous Flux [a.u.] 37.0 1000 If [mA] Vf [V] 36.0 35.0 34.0 33.0 100% 80% 60% 40% 20% 0% 0 25 50 Tc [C] 75 100 0 25 50 Tc [C] 75 100 6 Ref.CE-P3524 02/16 4-2. Optical Characteristics Spectrum : CRI(Ra) 80Min. 6500K 100% Tj=85 5000K 4000K 3500K 3000K If=540mA 2700K 90% 80% Radiative Intensity 70% 60% 50% 40% 30% 20% 10% 0% 380 430 480 530 580 630 Wave length [nm] Spectrum : CRI(Ra) 70Min. 680 730 Tj=85 5000K 4000K 780 If=540mA 3000K 100% 90% Radiative Intensity 80% 70% 60% 50% 40% 30% 20% 10% 0% 380 430 480 530 580 630 680 730 780 Wave length [nm] 7 Ref.CE-P3524 02/16 4-2. Optical Characteristics (continued) Radiation Characteristic -40 -30 -20 -50 10 -10 100% 20 30 40 50 80% -60 -70 60% 60 40% 70 X 20% -80 Y -90 80 90 0% 4-3. Derating Characteristics Case Temperature vs. Allowable Forward Current 1600 1400 If [mA] 1200 1000 800 600 400 200 0 0 25 50 75 Tc [C] 100 125 8 Ref.CE-P3524 02/16 5. Reliability 5-1. Reliability Test Test Item Test Condition IF=540mA Continuous Operation Test Ta=25C (with Al-fin) x1000hrs IF=540mA Tj=140C (with Al-fin) x1000hrs -40 C x 1000 hours Low Temperature Storage Test High Temperature Storage Test 100 C x 1000 hours Moisture-proof Test 85 C, 85 %RH for 500 hours Thermal Shock Test -40 C x 30 minutes - 100 C x 30 minutes, 100 cycle 5-2. Failure Criteria ( Tc=25C ) Measuring Item Symbol Measuring Condition Failure Criteria Forward Voltage Vf If=540mA >U x 1.1 Total Luminous Flux v If=540mA