RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview DM3058/DM3058E[1] is a digital multimeter designed with 51/2 digits readings resolution and dual-display especially fitting to the needs of high-precision, multifunction and automatic measurement. Applications Research&Development Laboratory Scientific Research and Education Detection and Maintenance Quality Test Automatic Production Test Main Features Easy to Use Design Real 51/2 digits readings resolution Up to 123 rdgs/s measurement speed True-RMS AC Voltage and AC Current measuring Quickly Save or Recall the 10 groups of Preset Configuration Preset 10 groups of Standard Sensor Configuration, built-in cold terminal compensation for thermocouple Clone the instrument configurations into other DM3058/DM3058E via USB storage device The first 51/2 digit digital multimeter passing LXI Criterion in industry, which can achieve system integration easily With easy, convenient and flexible any sensor measurement control software: UltraSensor Standard configuration interface: USB Device, USB Host, LAN (only for DM3058), RS-232, GPIB (only for DM3058) Support remote control via commands and compatible with commands of main stream multimeters 256x64 LCD Support double display, Chinese and English menu Built-in help system makes information acquisition more easier File management (support for USB-disk and local storage) Powerful Measurement Functions Basic Measurement Function DC Voltage: 200 mV ~ 1000 V DC Current: 200 A ~ 10 A AC Voltage: True-RMS, 200 mV ~ 750 V AC Current: True-RMS, 20 mA ~ 10 A 2-Wire, 4-Wire Resistance: 200 ~ 100 M Capacitance Measurement: 2 nF ~ 10000 F Continuity Test: Range is fixed at 2 k Diode Test: Range is fixed at 2.0 V Frequency Measurement: 20 Hz ~ 1 MHz Period Measurement: 1 s ~ 0.05 s Any Sensor Measurement: Support for 6 types of sensor (DCV, DCI, Freq, 2WR, 4WR and TC) Math Function Max, Min, Average, Standard Deviation, Pass/Fail, dBm, dB, Relative Measurement and Histogram Note[1]: The difference between DM3058 and DM3058E is only that DM3058E doesn't support LAN and GPIB interfaces. Nov. 2015 RIGOL TECHNOLOGIES, INC. Double Display Mirror Image Configuration Dual-display function makes your measurements achieve maximum results with little effort. It can display two performances of a signal simultaneously instead of two multimeters or measurements in the past. All the configurations (system and sensor configuration) can be cloned into other DM3058/DM3058E on product line via USB storage device to improve work efficiency. Preset Mode Pass/Fail Based on Preset Mode, the worker operation on product line could be greatly simplified. Besides, 10 groups of Preset Configuration are available to be stored and recalled. Pass/Fail test function can prompt for signals beyond the range based on specified higher and lower limit, and make test result more obvious. Any Sensor Measurement LXI & Web Control DM3058 is the first 51/2 digit digital multimeter passing LXI Criterion in industry that makes system integration easier. Any sensor measurement is a new conception being forward to meet user's requirements. By this particular function, you can easily connect pressure sensor or flux sensor or temperature sensor. Remote Control for DM3058 can be achieved by virtual panel from Web page in the same operation way with front panel of instrument. The multimeter supports 6 kinds of sensor (DCV, DCI, Freq, 2WR, 4WR and TC). Meanwhile, there are 10 groups of standard sensor configuration preset within the instrument. Thermocouple Cold Terminal compensation is built in the multimeter. Easy, Convenient and Flexible Control Software UltraSensor is used to control any sensor. The main functions include: Create a project for any sensor measurement which can be download to the multimeter; Connect with the multimeter to achieve any sensor measurement; Monitor the sensor data in real time and show them in the form of figure; Enable to save data in the format of CSV and TXT and reference curve in the format of BMP. UltraSensor Software Interface 1 Specifications DC Characteristics [2] Function Range DC Voltage 200.000 mV 2.00000 V 20.0000 V 200.000 V 1000.00 V[4] 200.000 A 2.00000 mA 20.0000 mA 200.000 mA 2.00000 A 10.0000 A[5] 200.000 2.00000 k 20.0000 k 200.000 k 2.00000 M 10.0000 M 100.000 M 2.0000 V[6] 2000 DC Current Resistance[3] Test current or Load voltage <8 mV <80 mV <0.05 V <0.5 V <0.1 V <0.3 V 1 mA 1 mA 100 A 10 A 1 A 200 nA 200 nA || 10 M 1 mA 1 mA Accuracy (% of reading + % of range)[1] 1 Year Temperature 23 5 Coefficient 0 - 18 28 - 50 0.015 + 0.004 0.0015 + 0.0005 0.015 + 0.003 0.0010 + 0.0005 0.015 + 0.004 0.0020 + 0.0005 0.015 + 0.003 0.0015 + 0.0005 0.015 + 0.003 0.0015 + 0.0005 0.055 + 0.005 0.003 + 0.001 0.055 + 0.005 0.002 + 0.001 0.095 + 0.020 0.008 + 0.001 0.070 + 0.008 0.005 + 0.001 0.170 + 0.020 0.013 + 0.001 0.250 + 0.010 0.008 + 0.001 0.030 + 0.005 0.0030 + 0.0006 0.020 + 0.003 0.0030 + 0.0005 0.020 + 0.003 0.0030 + 0.0005 0.020 + 0.003 0.0030 + 0.0005 0.040 + 0.004 0.0040 + 0.0005 0.250 + 0.003 0.0100 + 0.0005 1.75 + 0.004 0.2000 + 0.0005 0.05 + 0.01 0.0050 + 0.0005 0.05 + 0.01 0.0050 + 0.0005 Diode Test Continuity Test Remarks [1] Specifications are for 0.5 hour warm-up, "Slow" measurement rate and calibration temperature 18 ~ 28. [2] 20% over range on all ranges except for DCV 1000 V, ACV 750 V, DCI 10 A and ACI 10 A. [3] Specifications are for 4-wire measure or 2-wire measure under "REF" operation. 0.2 of extra errors will be generated if perform 2-wire measure without "REF" operation. [4] Plus 0.02 mV of error per 1 V after the first 500 VDC. [5] 30 seconds OFF after 30 seconds ON is recommend for the continuous current that higher than DC 7 A or AC RMS 7 A. [6] Accuracy specifications are only for voltage measuring at input terminal. The typical value of current under measure is 1 mA. Voltage drop at the diode junction may vary with current supply. DC Voltage Input Resistance Input Bias Current Input Protection CMRR (common mode rejection ratio) NMRR (normal mode rejection ratio) Resistance Testing Method Open-circuit Voltage Maximum Lead Resistance (4-wire resistance) Input Protection 200 mV and 2 V 10 M or >10 G selectable (Input signals that exceed 2.5 V in these ranges will pass the 100 k (typical) clamp resistance.) 20 V, 200 V and 1000 V 10 M 2% <90 pA, 25 1000 V on all ranges 120 dB (For the 1 k unbalanced resistance in LO lead, maximum 500 VDC 60 dB at "slow" measurement rate 20 dB are added if open the "AC filter" (Settling time will add 0.35 s while source impedance nears zero) 4-wire resistance or 2-wire resistance optional For current source refer to LO input P/F in <8 V 10% of ranges, on the range of 200 , 1 k, for each lead 1 k, on all other ranges, for each lead 1000 V, on all ranges 2 DC Current Shunt Resistor Input Protection 200 A sampling voltage < 8 mV 2 mA sampling voltage < 80 mV 1 for 20 mA, 200 mA 0.008 for 2 A, 10 A Rear panel: accessible 10 A, 250 V fast-melt fuse Internal: 12 A, 250 V slow-melt fuse Continuity / Diode Test Measurement Method 1 mA 5% constant-current source, < 8 V open-circuit voltage Response Time 123 samples/sec, with beeper Continuity Threshold Adjustable between 1 and 2000 Input Protection 1000 V Setup time Attentions The setup time about voltage measurement is influenced by source resistance and media characteristics of cable as well as input signal. AC Characteristics [2] Function Range True RMS AC Voltage[3] 200.000 mV 2.00000 V 20.0000 V 200.000 V 750.000 V True RMS AC Current[5] 20.0000 mA 200.000 mA 2.00000 A 10.0000 A[5] Accuracy (% of reading + % of range) [1] Frequency Range 1 Year Temperature 235 Coefficient 0 - 18 28 - 50 20 Hz - 45 Hz 1.5 + 0.10 0.01 + 0.005 45 Hz - 20 kHz 0.2 + 0.05 0.01 + 0.005 20 kHz - 50 kHz 1.0 + 0.05 0.01 + 0.005 50 kHz - 100 kHz 3.0 + 0.05 0.05 + 0.010 20 Hz - 45 Hz 1.5 + 0.10 0.01 + 0.005 45 Hz - 20 kHz 0.2 + 0.05 0.01 + 0.005 20 kHz - 50 kHz 1.0 + 0.05 0.01 + 0.005 50 kHz - 100 kHz 3.0 + 0.05 0.05 + 0.010 20 Hz - 45 Hz 1.5 + 0.10 0.01 + 0.005 45 Hz - 20 kHz 0.2 + 0.05 0.01 + 0.005 20 kHz - 50 kHz 1.0 + 0.05 0.01 + 0.005 50 kHz - 100 kHz 3.0 + 0.05 0.05 + 0.010 20 Hz - 45 Hz 1.5 + 0.10 0.01 + 0.005 45 Hz - 20 kHz 0.2 + 0.05 0.01 + 0.005 20 kHz - 50 kHz 1.0 + 0.05 0.01 + 0.005 50 kHz - 100 kHz 3.0 + 0.05 0.05 + 0.010 20 Hz - 45 Hz 1.5 + 0.10 0.01 + 0.005 45 Hz - 20 kHz 0.2 + 0.05 0.01 + 0.005 20 kHz - 50 kHz 1.0 + 0.05 0.01 + 0.005 50 kHz - 100 kHz 3.0 + 0.05 0.05 + 0.010 20Hz - 45 Hz 1.5 + 0.10 0.015 + 0.015 45 Hz - 2 kHz 0.50 + 0.10 0.015 + 0.006 2 kHz -10 kHz 2.50 + 0.20 0.015 + 0.006 20 Hz - 45 Hz 1.50 + 0.10 0.015 + 0.005 45 Hz - 2 kHz 0.30 + 0.10 0.015 + 0.005 2 kHz - 10 kHz 2.50 + 0.20 0.015 + 0.005 20 Hz - 45 Hz 1.50 + 0.20 0.015 + 0.005 45 Hz - 2 kHz 0.50 + 0.20 0.015 + 0.005 2 kHz - 10 kHz 2.50 + 0.20 0.015 + 0.005 20 Hz - 45 Hz 1.50 + 0.15 0.015 + 0.005 45 Hz - 2 kHz 0.50 + 0.15 0.015 + 0.005 2 kHz - 5 kHz 2.50 + 0.20 0.015 + 0.005 Additional wave crest factor error (not Sine)[6] Wave crest coefficient Error (% range) 1-2 0.05 2-3 0.2 Remarks: [1] Specifications are for 0.5 hour warm-up, "Slow" measure and calibration temperature 18 - 28. [2] 20% over range on all ranges except for DCV 1000 V, ACV 750 V, DCI 10 A and ACI 10 A. 3 [3] [4] [5] [6] Specifications are for amplitude of sine wave input >5% of range. 750 V range limited to 8x107 Volt-Hz. For inputs from 1% to 5% of range and <50 kHz, add 0.1% of range extra error. For 50 kHz to 100 kHz, add 0.13%. Specifications are for sine wave input >5% of range. 0.1% errors will be added when the range of input sine wave is 1% ~ 5%. 30 seconds OFF after 30 seconds ON is recommend for the continuous current that higher than DC 7 A or AC RMS 7 A. For frequency<100 Hz. True RMS AC Voltage Measurement Method Wave Crest Factor Input Impedance AC Filter Bandwidth CMRR (common mode rejection ratio) True RMS AC Current Measurement Method Wave Crest Factor Maximum Input Shunt Resistor Input Protection AC coupled true RMS measure - up to 1000 V DC bias are permitted on every range 3 at full scale 1 M 2% in parallel with <100 pF on all ranges 20 Hz ~ 100 kHz 60 dB (For the 1 k imbalance resistance among Lo lead and <60 Hz, maximum 500 VDC) DC coupled to the fuse and shunt; AC coupled the True RMS measurement (measures the AC components only) 3 at full scale The DC + AC current peak value <300% of range. The RMS current including DC current is <10 A 1 for 20 mA, 200 mA 0.008 for 2 A, 10 A Rear panel: accessible 10 A, 250 V fast-melt fuse Internal: 12 A, 250 V slow-melt fuse Setup Time Attentions Make sure that the RC return at input terminal has been in a stable state completely (higher than 1 s) before accurate measurement; Input >300 Vrms (or >5 Arms) will cause the self heating of the signal conditioning component to generate error, this error is included in the characteristics of the instrument. Internal temperature variation results from the self heating will cause additional an error on ac range that is lower than 0.03% of readings, and it will disappear after a few minutes. Frequency and Period Characteristics Function Range Frequency Range Frequency/Period 200 mV - 750 V[2] 20 Hz - 2 kHz 2 kHz - 20 kHz 20 kHz - 200 kHz 200 kHz - 1 MHz 20 mA - 10 A[3] 20 Hz - 2 kHz 2 kHz - 10 kHz Accuracy (% of reading + % of range) [1] 1 Year Temperature 235 Coefficient 0 - 18 28 - 50 0.01 + 0.003 0.002 + 0.001 0.01 + 0.003 0.002 + 0.001 0.01 + 0.003 0.002 + 0.001 0.01 + 0.006 0.002 + 0.002 0.01 + 0.003 0.01 + 0.003 0.002 + 0.001 0.002 + 0.001 Remarks: [1] Specifications are for 0.5 hour warm-up. [2] Except for special marks, the AC input voltage is 15% to 120% of range when <100 kHz and 40% to 120% of range when >100 kHz. 750 V range is limited to 750 VRMS. 200 mV ranges is for full scale or higher. For inputs from 30 mV to 200 mV, multiply total % of reading error by 10. [3] For AC input current from 15% to 120% of range except where noted. 20 mA range specifications are for full scale. For inputs from 5 mA to 20 mA, multiply total % of reading error by 10. 10 A range is for AC input current from 25% to 100% of range. Frequency and Period Measurement Method: Reciprocal-counting technique, AC-coupled input, AC voltage or AC current measurement function Measure Attentions Generally, errors are leaded into all frequency counters when measuring low voltage or low frequency signal. Shielding input can extremely help to reduce measuring errors caused by exterior noise. Setup Time Attentions 4 If the variational DC components appeared in signals under measure, errors may be caused while measuring period or frequency. Please ensure that the RC loop at input terminal must be stable during exact measuring (higher than 1 sec). Capacitance Characteristics Function Range[2] Maximum Testing Current Capacitance 2.000 nF 20.00 nF 200.0 nF 2.000 F 200 F 10000 F 200 nA 200 nA 2 A 10 A 100 A 1 mA Accuracy (% of reading + % of range) [1] 1 Year Temperature Coefficient 235 0 - 18 28 - 50 3 + 1.0 0.08 + 0.002 1 + 0.5 0.02 + 0.001 1 + 0.5 0.02 + 0.001 1 + 0.5 0.02 + 0.001 1 + 0.5 0.02 + 0.001 2 + 0.5 0.02 + 0.001 Remarks: [1] Specifications are for 0.5 hour warm-up and "REF" operation. Using of non-film capacitor may generate additional errors. [2] Specifications are for from 1% to 120% on 2 nF range and ranges from 10% to 120% on other ranges. Capacitance Measuring Measurement Method Measure the rate of change of voltage generated during the current flowing the capacitance Connection Type 2-wire Input Protection 1000 V on all ranges Measure Attentions: Small capacitance is easily influenced by external noise and thus causes errors while measuring, shielding input can extremely help to reduce this kind of errors. Other Measuring Characteristics Triggering and Memory Samples/Trigger 1 ~ 2000 Trigger Delay 8 ms ~ 2000 ms optional Input Level External Trigger Input VMC Output Trigger Condition Input Impendence Min Pulse Electric Level Output Polarity Input Impedance TTL compatible (High level when left input terminal is hanging in the air) Rising edge/falling edge selectable >20 k, in parallel with 400 pF, DC-coupled 500 s TTL compatible ( input >=1 kohm loads straight polarity and negative polarity optional 200 ohm, typical Arbitrary Sensor Support for multiply types of sensor such as Thermocouple, DC Voltage, DC Current, Resistance (2-wire or 4-wire) and Frequency output; With thermocouple compensation at cold junction. Output Polarity: straight polarity and negative polarity optional Preset ITS-90 transform of B, E, J, K, N, R, S and T thermocouple and transform of platinum Pt100, Pt385 resistance temperature sensor Math Functions Pass/Fail, REL (RELative), Min/Max/Average, dBm, dB, Hold, Historgram, Standard deviation History Records Volatile Memory 2000 readings of history records Nonvolatile Memory 10 gourps of history records (2000 readings/group); 10 groups of sensor records: (1000 readings/group); 10 groups of setting records of instrument; 10 groups of setting records of arbitrary sensor; support USB-disk external storage 5 General Specifications Power Supply AC 100 V ~ 120 V AC 200 V ~ 240 V Consumption Mechanism Dimension Weight Other Characteristics Display Screen Operating Environment 45 Hz ~ 440 Hz 45 Hz ~ 66 Hz 20 VA peak value 107.0 mmx231.6 mmx290.5 mm 2.5 kg LCD display with 256x64 lattices, support for Double display, Menu display, Operating help and English/Chinese bilingual. Full accuracy from 0 to 50; 80% R.H. and 40, non condensing Storage Temperature: -20 ~ 70 Shock and Vibration: conforming to MIL-T-28800E, III, 5 level (only for sine) Programmer Language height above sea level: up to 3000 meters Conforming to IEC61010-1: 2001. Measure CAT I 1000 V/CAT II 600 V Class of pollution: 2 GPIB (only for DM3058), 10/100Mbit LAN (only for DM3058), USB2.0 Full Speed Device & (USB-disk available), RS-232C RIGOL 3058 SCPI, FLUKE45, Agilent34401A LXI Compatibility LXI Class C, Version1.1 (only for DM3058) Warm Up Time 30 minutes Safety Remote Interface 6 Ordering Information Warranty Name of Product Thank you very much for choosing RIGOL products! RIGOL DM3058/DM3058E Digital Multimeter Standard Accessories A Power Cord that fits the standard of destination country Two Test Leads (black and red) Two Alligator Clips (black and red) An USB Data Cable A Backup Fuse A Quick Guide User's Guide and Application software (CD-ROM) Optional Accessories Kelvin Test Clips RS232 Cable RIGOL warrants that the product mainframe and product accessories will be free from defects in materials and workmanship within the warranty period. If a product proves defective within the respective period, RIGOL guarantees free replacement or repair of any defective products within a reasonable period of time. To get repair service, please contact with your nearest RIGOL sales or service office. There is no other warranty, expressed or implied, except such as is expressly set forth herein or other applicable warranty card. There is no implied warranty of merchantability or fitness for a particular purpose. Under no circumstances shall RIGOL be liable for any consequential, indirect, ensuing or special damages for any breach of warranty in any case. Contact Us If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Websites: www.rigol.com 7