IS62WV12816ALL, IS62WV12816BLL ISSI
®
Integrated Silicon Solution, Inc. — www.issi.com —
1-800-379-4774
5
PRELIMINARY INFORMATION Rev. 00A
04/1502
IS62WV12816ALL, POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter Test Conditions Max. Unit
70
ICC Vcc Dynamic Operating VCC = Max., Com. 15 mA
Supply Current IOUT = 0 mA, f = fMAX Ind. 20
ICC1Operating Supply VCC = Max., Com. 3 mA
Current IOUT = 0 mA, f = 0 Ind. 3
ISB1TTL Standby Current VCC = Max., Com. 0.3 mA
(TTL Inputs) VIN = VIH or VIL Ind. 0.3
CS1 = VIH , CS2 = VIL,
f = 1 MHZ
OR
ULB Control
VCC = Max., VIN = VIH or VIL
CS1 = VIL, f = 0, UB = VIH, LB = VIH
ISB2CMOS Standby VCC = Max., Com. 5 µA
Current (CMOS Inputs) CS1
≥
VCC – 0.2V, Ind. 10
CS2
≤ 0.2V,
VIN
≥
VCC – 0.2V, or
VIN
≤
0.2V, f = 0
OR
ULB Control VCC = Max., CS1 = VIL, CS2=VIH
VIN ≤ 0.2V, f = 0; UB / LB = VCC – 0.2V
IS62WV12816BLL, POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter Test Conditions Max. Max. Max. Unit
45 55 70
ICC Vcc Dynamic Operating VCC = Max., Com. 35 25 20 mA
Supply Current IOUT = 0 mA, f = fMAX Ind. 40 30 25
ICC1Operating Supply VCC = Max., Com. 3 3 3 mA
Current IOUT = 0 mA, f = 0 Ind. 3 3 3
ISB1TTL Standby Current VCC = Max., Com. 0.3 0.3 0.3 mA
(TTL Inputs) VIN = VIH or VIL Ind. 0.3 0.3 0.3
CS1 = VIH , CS2 = VIL,
f = 1 MHZ
OR
ULB Control
VCC = Max., VIN = VIH or VIL
CS1 = VIL, f = 0, UB = VIH, LB = VIH
ISB2CMOS Standby VCC = Max., Com. 10 10 10 µA
Current (CMOS Inputs) CS1
≥
VCC – 0.2V, Ind. 10 10 10
CS2
≤ 0.2V,
VIN
≥
VCC – 0.2V, or
VIN
≤
0.2V, f = 0
OR
ULB Control VCC = Max., CS1 = VIL, CS2=VIH
VIN ≤ 0.2V, f = 0; UB / LB = VCC – 0.2V
Note:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.