CSM_K3SC_DS_E_4_2
1
Interface Converter
K3SC
A compact converter that allows
communications between RS-232C/USB and
RS-422/485 devices. Ideal for industrial
applications.
Allows communications between RS-232C/USB (Universal
Serial Bus) and RS-422/485 devices.
Applicable in FA environments: Has passed environment
resistance tests equivalent to those for control devices.
CE marking (except for USB).
UL/CSA certification (mark license recognition).
Compact 30-mm-wide body supports both screw-mounting and
DIN track mounting.
Operation either with or without echoback available.
Functionality to convert between USB and RS-232C
communications added.
USB driver providing virtual communications port for USB
communications is available.
Note: To use USB communications, the USB driver for the K3SC must be
downloaded from the OMRON web site.
Application Examples
Data can be transferred between computers (using the USB port if
there is no RS-232C port) and field devices.
Using two K3SC Units enables long-distance communications between
devices connected via RS-232C.
Refer to Safety Precautions on page 8.
Ordering Information
List of Models
Appearance Size (mm) Power supply voltage Model
30 × 80 × 78 (W × H × D) 100 to 240 VAC K3SC-10 100 to 240 VAC
24 VAC/VDC K3SC-10 24 VAC/VDC
K3SC
2
Accessories (Order Separately)
Adapter for RS-232C Serial Cable and K3SC (D-Sub, 9-pin, male)
Specifications
Ratings
Appearance Wiring diagram Model
K32-23209
50
3
2
5
7
8
6
4
SD
RD
SG
RS
CS
DR
ER
Pin Signal
D-Sub, 9-pin
M3.5 terminals
SD (orange)
RD (white)
SG (gray)
Send data
Receive data
Signal ground
Request to send
Clear to send
Data set ready
Data terminal ready
Item K3SC-10 100 to 240 VAC K3SC-10 24 VAC/VDC
Supply voltage 100 to 240 VAC 50/60 Hz 24 VAC 50/60 Hz, 24 VDC
Operating voltage range 85% to 110% of power supply voltage
Power consumption 5 VA max. 3 VA max./3 W max.
Master/slave device communications format
(Select one of the formats listed on the right
using the DIP switch.)
Master Device Slave Device
RS-232C or USB RS-485, half duplex
RS-232C or USB RS-422, full duplex
USB RS-232C, full duplex
Communications method Start-stop synchronization
Ambient operating
temperature
RS-232C –10 to 55 °C (with no icing)
USB 0 to 55 °C (with no icing)
Ambient operating humidity 25% to 85% (with no condensation)
Ambient storage temperature –20 to 65 °C
K3SC
3
Characteristics
Note: 1. With RS-232C communications, free-run mode is supported for SD and RD but not for any other signal lines.
2. To use USB communications, the USB driver for the K3SC must be downloaded from the OMRON web site.
http://www.fa.omron.co.jp/
3. The enclosure ratings do not apply when USB is used.
4. The CE marking does not apply when the K3SC is used for USB.
Item Specification
Master device
RS-232C
interface
(See note 1.)
Maximum transmission
distance
15 m
Maximum number of
connectable Units
1 Unit
USB interface
(See note 2.)
Maximum transmission
distance
5 m; hub delay time + cable delay time 70 ns
Maximum number of
connectable Units
1 Unit
USB standard V1.1
Slave device
RS-485
interface
Maximum transmission
distance
500 m
Maximum number of
connectable Units
31 Units (for multi-drop connection)
RS-422
interface
Maximum transmission
distance
500 m
Maximum number of
connectable Units
1 Unit
Baud rate 1,200/2,400/4,800/9,600/19,200/38,400 (bps)
Default setting: 9,600
Data length 7/8 bits
Default setting: 7
Stop bit length 1/2 bits
Default setting: 2
Communications parity None/even/odd
Default setting: Even
Echoback selection Echoback: With/without
Default setting: Without
Selection switch response delay Approx. 30 ms
Insulation resistance 20 MΩ min. measured at 500 VDC between the following:
External terminals casing
RS-232C terminals and USB port RS-422/485 terminals power supply terminals
Isolation
method
Communi-
cations
Phototransistor coupler
Power
supply
Isolating transformer
Dielectric strength 1,500 VAC for 1 minute measured between the following:
External terminals casing
RS-232C terminals, USB port, RS-422 terminals, and RS-485 terminals power supply terminals
500 VAC for 1 minute measured between the following:
RS-232C terminals and USB port RS-422 terminals and RS-485 terminals
Noise immunity AC power supply terminals, normal/common mode: ±1,500 V
AC/DC power supply terminals, normal mode: ±480 V; common mode: ±1,500 V
Square wave with 1-ns rising edge ±1μs, ±100 ns
Vibration resistance Malfunction 10 to 55 Hz, 0.5-mm single amplitude for 10 minutes each in X, Y, and Z directions
Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Malfunction 98 m/s2 3 times each in X, Y, and Z directions
Destruction 294 m/s2 3 times each in X, Y, and Z directions
Weight Approx. 150 g
Degree of protection
(See note 3.)
Front panel operation
parts
Conforms to IEC standards, equivalent to IP20 (when terminal cover mounted)
Terminals Equivalent to VDE 0106/100 (when terminal cover mounted)
EMC (EMI) EN61326-1 Industrial electromagnetic environment
Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/-2
Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/-2
(EMS) EN61326-1 Industrial electromagnetic environment
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3)
Immunity Fast Transient Noise: EN61000-4-4: 2 kV (power line) (level 3)
Immunity Burst Noise: 1 kV line to line (I/O signal line)
Immunity Surge: EN61000-4-5: 1 kV line to line
2 kV line to ground (power line)
Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180°, 100% (rated voltage)
Approved standards UL508,
Conforms to EN61326-1, EN61010-1 (IEC61010-1)
Memory protection No protective functions (Communications data is not protected for power interruptions during communications.)
K3SC
4
Connections
Terminal Specifications
Be sure to check the input and output specifications for the signal pins of connected devices before connecting the terminals.
Note: Terminals 2 and 10 are not used.
Internal Configuration (Block Diagram)
Function Terminal
number
Name Signal direction Explanation
For connecting the
operating power supply
1 and 4 PWR --- The input power supply specifications vary with the model.
A 100 to 240-VAC model and a 24-VAC/VDC (no-polarity) mod-
el are available.
Connection terminals for
RS-232C
communications with
master device
(DIP switch pin 8: OFF)
3 SG --- Connect to signal ground.
5 SD Input Receives data from SD of the master device.
6 RD Output Sends data to RD of the master device.
Used for RS-485
communications with slave
device
(DIP switch pin 9: OFF)
8RDA() Input/output SD and RD for RS-485 (cold side)
Terminals 8 and 9 are connected internally when pin 9 of the
DIP switch is set to OFF.
9SDA()
11 RDB(+) Input/output SD and RD for RS-485 (hot side)
Terminals 11 and 12 are connected internally when pin 9 of the
DIP switch is set to OFF.
12 SDB(+)
Used for RS-422
communications with slave
device
(DIP switch pin 9: ON)
7 SG --- Connect to signal ground.
8RDA() Input Receives RS-422 data and outputs it to the master side.
9SDA() Output Converts data received via RS-232C from the master device to
RS-422 data and outputs the data.
11 RDB(+) Input Receives RS-422 data and outputs it to the master side.
12 SDB(+) Output Converts data received via RS-232C from the master device to
RS-422 data and outputs the data.
DIP switch Status
indicator
Power
indicator
PHC
PHC
PHC
RS-232C
USB USB
controller
RS-232C
driver
DIP switch Status
indicator
Power
indicator
Power
supply
Switch input
USB control
Indicator control
Serial
communi-
cations
RS-485 enabling
control
RS-485 driver RS-422 or
RS-485
Insulation
Serial
communi-
cations
CPU
PHC
PHC
PHC
K3SC
5
External Connections
RS-485 Connection
Note: 1. If RS-485 is selected as the communications method (i.e.,
pin 9 of the DIP switch is set to OFF), terminals 8 and 9, and
terminals 11 and 12 are connected internally.
2. Either a 100 to 240-VAC or 24-VAC/VDC (no polarity) input
power supply is used.
RS-422 Connection
Note: Either a 100 to 240-VAC or 24-VAC/VDC (no polarity) input
power supply is used.
Connecting an RS-232C or USB Master Device to an RS-422/485 Slave Device
First set the same communications conditions (baud rate, stop bits, data length, and parity) for the master device, the Interface Converter, and
slave devices.
Note: 1. 1-to-N connection via OMRON NT Link communications is not supported.
2. If the communications interface format for the master device is USB, obtain a commercially available USB cable and download the USB
driver for the K3SC from the OMRON web site.
Connecting a USB Master Device to an RS-232C Slave Device
First set the same communications conditions (baud rate, stop bits, data length, and parity) for the master device, the Interface Converter, and
slave devices.
Note: There is no isolation between the USB and RS-232C sides.
3
2
5
7
8
6
4
()
(+)
789
10 11 12
456
123
K3SC
Input power supply
(See note 2.)
(See note 1.)
(See note 1.)
Slave device side
RS-485
Master device side
RS-232C
Abbre-
viation
SD
RD
SG
RS
CS
DR
ER
SD RD
SG
Pin number (for 9-pin
computer connector)
789
10 11 12
456
123
3
2
5
7
8
6
4
K3SC
Slave device side
RS-422
Master device side
RS-232C
SD RD
SG
Input power supply
(See note.)
Abbre-
viation
SD
RD
SG
RS
CS
DR
ER
Pin number (for 9-pin
computer connector)
Abbreviation
SG
SDA ()
SDB (+)
RDA ()
RDB (+)
RDA (
)SDA (
)
RDB (+) SDB (+)
SG
AL1
AL2
HB
OT
1
OT
2
STP
CMW
K3SC
K32-23209
If the communications interface format
for the master device is RS-232C, set
pin 8 of the DIP switch to OFF.
Computer
Note: To allow connection using a commercially available cable with an
RS-232C D-sub connector, a connection adapter (D-sub, 9-pin) is
available. (Order separately; model number: K32-23209.) Note: With RS-485 communications, connect a terminating resis-
tance (120 Ω, 1/2 W recommended) to both ends of the com-
munications path.
In addition to the required communications
conditions, set the communications number.
Devices connected
via RS-485 (example)
Wire with
stranded wires.
Cable with RS-232C D-sub connector
Computer
Note: Use a commercially available USB cable. K3SC
USB connection
Set pin 8 of the DIP switch to ON to select
the following communications format:
Master device: USB; Slave device: RS-232C
Measuring/testing device
RS-232C
Note: The USB driver is available
from the OMRON web site.
http://www.fa.omron.co.jp/
Wire with stranded wires.
K3SC
6
Operation
Communications Settings Switch
Use this switch to set the communications conditions for the K3SC to those used by connected devices.
Note: 1. All pins are factory-set to OFF.
2. When using RS-422 full-duplex communications, turn OFF pin 0.
3. When using the communications configuration with RS-232C or USB set for the master device and RS-422 or RS-485 set for the slave
device, use either RS-232C or USB (but not both) on the master device side.
Nomenclature
Setting
ONOFF
Baud rate Data length Stop bits Parity Configuration Echoback
1,200
bps
2,400
bps
4,800
bps
9,600
bps
19,200
bps
38,400
bps
7 8 2 1 Even Odd None Master:
USB
Master:
RS-232C
or USB
(See note.)
OFF
(with-
out)
ON
(with)
Slave:
RS-
232C
Slave:
RS-
485
Slave:
RS-
422
ON OFF ON OFF ON OFF
OFF ON ON OFF OFF ON
OFF OFF OFF OFF ON ON
OFF ON
OFF ON
OFF ON OFF
OFF OFF ON
ON OFF
OFF ON
OFF ON
1
2
3
4
5
6
7
8
9
10
K3SC without Terminal CoverTerminal Cover
Caution: Be sure to use the K3SC-10 with
the terminal cover mounted
when using in machinery that
must conform to EN/IEC stan-
dards.
Note: Cover the terminals to prevent electric shock.
Power Indicator
Lights (green) when
power is supplied.
Communications Setting Switch
Used to set the communications conditions for
connected devices.
Communications Setting Switch
Switch Setting
Baud rate
Data length
Parity
Master device
Slave device
Echoback
Communications Status Indicators
Light (yellow) during communications.
RS-232C/USB RS-422/485:
RD: Lights when receiving RS-422/485 communications.
SD: Lights when sending RS-422/485 communications.
USB RS-232C:
RD: Lights when receiving RS-232C communications.
SD: Lights when sending RS-232C communications.
USB Port
Port for USB connections. Use this port
if the master device is a USB device.
M3.5 Terminal Screw
K3SC
7
Dimensions
K3SC-10
78
51.523.53
30
80
75
7
72±0.3
Mounting Hole Dimensions
(For Direct Mounting)
Two, M4 or 4.3-dia. holes
Note: DIN track mounting is also possible.
K3SC
8
Safety Precautions
!CAUTION
General Precautions
Do not mount the product in the following places:
1. Locations subject to shock or vibration
2. Outdoor locations or locations subject to direct sunlight, wind, or
rain.
3. Locations subject to temperatures or humidity outside the
specified ranges
4. Locations subject to condensation or icing
5. Locations subject to large amounts of dust
6. Locations subject to flammable gases or objects
7. Locations subject to corrosive gases (in particular sulfide or
ammonia gases)
Be sure to check power supply specifications, terminal numbers,
and polarities before performing wiring.
Turn OFF the power supply before performing installation or wiring.
Turn OFF the power supply before removing the terminal cover.
Accidentally touching the terminals may result in electric shock.
Do not connect anything to unused terminals.
Correct Use
Perform wiring with crimp terminals that are suitable for M3.5
screws.
Install the product as far away as possible from devices that
generate strong high-frequency noise (e.g., high-frequency
welders) or surges.
Do not pull on the USB cable. Doing so may cause the cable to
come loose.
Almost all application programs run with the K3SC driver, which
provides a virtual communications port for USB communications.
Some application programs do not run, because this driver does
not support all of the API functions.
The K3SC-10 is not simply a voltage level converter.
Communications data is converted by a built-in CPU. Depending on
communications conditions, processing may not be able to keep up
with communications, and occasionally data corruption or data
omissions may occur. If necessary, reduce the baud rate or the
frequency of communications, or take other suitable
countermeasures.
Do not touch any of the terminals while power is being
supplied. Doing so may result in electric shock.
Do not allow metal objects or wire cuttings to enter the
product. Doing so may result in electric shock, fire, or
malfunction.
Do not attempt to disassemble, repair, or modify the
product. Any attempt to do so may result in malfunction,
fire, or electric shock.
Make sure that the power supply voltage is within the
specified range. Otherwise, damage or burning may
result.
Be sure to tighten the terminal screws to the specified
torque. Loose screws may result in burning or
malfunction. The recommended tightening torque is
0.78 N·m.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.