https://www.phoenixcontact.com/us/products/2904903 Temperature measuring transducer - MACX PL-T-UIREL-UP-SP - 2904903 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer with 2, 3 or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, spring-cage connection, PLd The figure shows a version with a screw connection Product Features Key commercial data Packing unit 1 pc Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 35 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C Maximum altitude 2000 m Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing) Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. 05/18/2015 Page 1 / 5 https://www.phoenixcontact.com/us/products/2904903 Temperature measuring transducer - MACX PL-T-UIREL-UP-SP - 2904903 Technical data Input data Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG Temperature measuring range -200 C ... 850 C Input signal range 0 ... 50 k Potentiometer resistance range 0 ... 50 k Input signal range -1000 mV ... 1000 mV Output data Current output signal 4 mA ... 20 mA Max. current output signal 22 mA Load/output load current output 600 (at 20 mA) Behavior in the event of a sensor error according to NE 43 or freely configurable Output name Relay output Output description 1 SIL/PL Contact type 2 PDT Contact material AgSnO2, hard gold-plated Maximum switching voltage 250 V AC (250 V DC) Maximum inrush current 2 A (250 V AC) 2 A (28 V DC) 0.2 A (120 V DC) Power supply Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz) Power consumption < 2.4 W Connection data Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 1.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Connection method Push-in connection General Maximum transmission error 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA) Maximum temperature coefficient 0.01 %/K Inflammability class according to UL 94 V0 Pollution degree 2 05/18/2015 Page 2 / 5 https://www.phoenixcontact.com/us/products/2904903 Temperature measuring transducer - MACX PL-T-UIREL-UP-SP - 2904903 Technical data General Surge voltage category II Housing material PA 66-FR Color yellow Designation Input/output/power supply Electrical isolation 300 Vrms (Rated insulation voltage (surge voltage category II; pollution degree 2, safe isolation as per EN 61010-1)) 2.5 kV (50 Hz, 1 min., test voltage) Designation Input/output Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Input/power supply Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Input/switching output Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Conformance CE-compliant ATEX II 3 G Ex nA nC ic IIC T4 Gc X IECEx Ex nA nC ic IIC T4 Gc X UL, USA / Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 Classifications eCl@ss eCl@ss 5.1 27210107 eCl@ss 6.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 Approvals Approvals Approvals UL Listed / cUL Listed / GL / Functional Safety / cULus Listed 05/18/2015 Page 3 / 5 https://www.phoenixcontact.com/us/products/2904903 Temperature measuring transducer - MACX PL-T-UIREL-UP-SP - 2904903 Approvals Ex Approvals ATEX / IECEx / UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details UL Listed cUL Listed GL Functional Safety cULus Listed Drawings Block diagram IN Sensor / Field OUT PLC / DCS passive RTD TC - + 4.3 4.3 4.2 4.2 4.1 4.1 3.3 3.3 OUT 3.2 3.2 GND I + 3.1 Poti 3.6 34 4.3 3.5 31 4.2 3.4 32 4.1 5.3 DI 5.3 5.2 5.2 5.1 5.1 2.6 24 2.5 21 NC 1.3 Power 24V ...230V AC/DC 1.2 2.4 22 1.1 Zone 2 Div. 2 1.6 14 1.5 11 DI 1.4 12 05/18/2015 Page 4 / 5 https://www.phoenixcontact.com/us/products/2904903 Phoenix Contact 2015 (c) - all rights reserved http://www.phoenixcontact.com 05/18/2015 Page 5 / 5