200W Single Output with PFC Function EPP-200 series
SPECIFICATION
MODEL
DC VOLTAGE
CURRENT 10CFM
10CFM
Convection
Convection
RATED
POWER
OUTPUT
LINE REGULATION
VOLTAGE ADJ. RANGE
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
INPUT
FUNCTION
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING HUMIDITY
WORKING TEMP.
FAN SUPPLY
OVER TEMPERATURE
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
12ms/230VAC 12ms/115VAC at full load
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
PF>0.94/230VAC PF>0.98/115VAC at full load
93%93% 94%
16.5 ~ 19.5V
94%
26.4 ~ 31.2V
94%
29.7 ~ 35V 52.8 ~ 62.4V
1.8A/115VAC 1A/230VAC
COLD START 30A/115VAC 60A/230VAC
110 ~ 140% rated output power
13.2 ~ 15.6V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to "Derating Curve")℃
12V@0.5A for driving a fan ; tolerance +15% ~ -15%
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
500.2Khrs min. MIL-HDBK-217F (25 )℃
101.6*50.8*29mm (L*W*H)
0.19Kg; 72pcs/14.7Kg/0.82CUFT
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
±0.5% ±0.5%
±1.0% ±1.0%
±0.5%
±2.0% ±2.5% ±1.0% ±1.0% ±1.0%
100mVp-p
11.4~12.6V 14.3~15.8V 22.8~25.2V 25.6 ~ 28.4V 45.6 ~50.4V
100mVp-p 150mVp-p 150mVp-p 200mVp-p
15V 24V 27V 48V
16.7A
11.7A
13.4A
9.4A
8.4A
5.9A
7.5A
5.3A
4.2A
3A
200.4W
140.4W 141W
201W
141.6W
201.6W
143.1W
202.5W
144W
201.6W
EPP-200-12 EPP-200-15 EPP-200-24 EPP-200-27 EPP-200-48
SAFETY STANDARDS
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by
mounting the unit on a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets 360 360
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher ℃℃
than 2000m(6500ft).
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
Protection type : Shut down o/p voltage, re-power on to recover
Compliance to EN55032 (CISPR32) Conduction for Class B Radiation for Class B with FG(Class ) andⅠ
Class A without FG(Class ), EN61000-3-2,-3,ⅡEAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020
UL62368-1, TUV EN62368-1, IEC62368-1, approvedEAC TP TC 004
12V
EMC IMMUNITY
EMC EMISSION
<0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
OPERATING ALTITUDE Note.6
5000 meters
File Name:EPP-200-SPEC 2019-07-03