Recommended Tooling (Daniel's Manufacturing)
RG-174, RG-316, Cables RG-58
Center
Pin Ferrule(Single) Ferrule(Dual)Center Pin Ferrule(Single) Ferrule(Dual)
Hand Crimp Tool AFM8 HX4 HX4 AFM8 HX4 HX4
Pneumatic Crimp
Tool WA22 HX23 HX23 WA22 HX23 HX23
Die Set
(Positioner) K727 Y119 or Y1831 Y1831 K1470 Y188 or Y1832 Y1832
Depth Setting 4 or 5* - - 6 or 7* - -
Please note: The dual ferrule die sets can be used on the single ferrule designs.
* Depth setting should be used at minimum setting which will yield wire minimum 5 lbs pull-off
force.
* Depth setting requirements depend upon several factors including wire manufacturer + grade.
FAKRA SMB Specifications
Electrical
Impedance 50 ©
Frequency Range DC - 4 GHz
Performance Spec SAE-USCAR-17, 18
VSWR DC - 2 GHz 2 GHz - 4 GHz
Spec requirement 1.40 max 1.50 max
Straight SMB (cable group 1) 1.15 max 1.25 max
Right angle SMB (cable group 1) 1.20 max 1.35 max
Straight SMB (cable group 4) 1.10 max 1.15 max
Insertion Loss Spec requirement: < .3 dB max from DC - 3GHz
Up to 1 GHz: < .1 dB
Up to 2 GHz: < .2 dB
Up to 4 GHz: < .3 dB
Insulation Resistance 1000 M© minimum
Center Contact Resistance Center contact: < 20 m©
Outer contact: < 10 m©
Dielectric Withstanding Voltage > 1,000 VRMS at sea level
Mechanical
Mating Durability 100 mating cycles minimum
Plastic Housing Engagement Force Engagement: = 20 N
Disengagement: = 25 N
Cable Retention Force Cable group 1: = 110 N
Cable group 4: = 180 N
Coding 12 mechanical and color codings
Material
Plastic Housing PBT with 15% Glass Fiber
Secondary Locking Clip PBT with 15% Glass Fiber
Center Contact Male: Brass
Female: Beryllium copper
Body Brass
Barrel Brass
Retainer Ring Beryllium copper
Ferrule Copper