Ratiometric Linear Hall-effect Sensor OHN3150U, OHN3151U, OHS3150U, OHS3151U Features: * * * * * Ratiometric linear output capable of sinking and sourcing current 4.5 V to 6.0 V operation Responds equally to positive and negative magnetic fields Excellent temperature stability to operate in harsh environments Robust package capable of withstanding harsh environments Product Photo Here Through Hole Description: Each ratiometric linear Hall-effect sensor contains a monolithic integrated circuit on a single chip. This circuit incorporates a quadratic Hall sensing element, which minimizes the effects of mechanical and thermal stress on the Hall element and temperature compensating circuitry to compensate for the inherent Hall element sensitivity change over temperature current. These ratiometric linear Hall-effect sensors provide an output voltage that varies in proportion to the applied magnetic field. The voltage output will increase in response to a south pole (positive) magnetic field applied perpendicular to the package symbolization face, and will decrease in response to a north pole (negative) magnetic field. These 3150U & 3151U ratiometric linear Hall-effect sensors can be used as a non-contact sensor for rotary and linear position sensing and for current sensing. The devices in this series are similar in performance, except for their allowable quiescent voltage output change over the specified operating temperature range. Applications: * * * * * * Ordering Information Non-contact magnetic sensing Through Hole Temp. Range Machine automation OHN3150U -20C to +85C Machine safety OHS3150U -40C to +150C OHN3151U -20C to +85C OHS3151U -40C to +150C Assembly line automation Door sensor Where sensing is required in dirty environments VOQ Threshold VOQ Change over TA = 35 Gauss VOQ Change over TA = 50 Gauss 1 Vcc Voltage Regulator Qual Hall Element Dual to Single Converter Vcc 3 Output 2 Gnd DIMENSIONS ARE IN: RoHS [MILLIMETERS] INCHES OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. OPTEK Technology Inc. -- 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com Issue B.1 01/09 Page 1 of 4 Ratiometric Linear Hall-effect Sensor Emitting Diode OHN3150U, OHN3151U, OHS3150U, OHS3151U Absolute Maximum Ratings Supply Voltage, VCC 6V Storage Temperature Range, TS -65C to +170 C Operating Temperature Range, TA (OHS prefix) (OHN prefix) -40C to +150 C -20C to +85 C Lead Soldering Temperature (1/8 inch [3.2 mm] from case for 5 seconds with soldering iron) 260 C(1) Power Dissipation, PD 100 mW 5 mA Output Current, IO Magnetic Flux Density, B Unlimited Electrical Characteristics (Over Operating Temperature Range at VCC = 5 V, unless otherwise noted) SYMBOL PARAMETER VCC Supply Voltage ICC Supply Current VOQ Quiescent Voltage Output MIN TYP MAX UNITS 4.5 5.0 6.00 V 5.5 10.00 mA 2.25 2.5 2.75 V B = OG, TA = 25 C 2.10 2.5 2.90 V B = OG, TA = -40C to +150C IO Sink Current 0.5 mA IO Source Current -1.0 mA OHS3150U SYMBOL PARAMETER TA Operating Temperature Range Sens MIN OHS3151U TYP MAX TEST CONDITIONS Vcc = 6 V, IO = 0 mA, B = OG OHN3150U MIN TYP MAX MIN OHN3151U TYP MAX MIN TYP MAX UNITS -40 - 150 -40 - 150 -20 - 85 -20 - 85 C Sensitivity @ TA = 25 C over TA 2.25 2.0 2.5 - 2.75 3.0 2.25 2.0 2.5 - 2.75 3.0 2.25 2.0 2.5 - 2.75 3.0 2.25 2.0 2.5 - 2.75 3.0 mV/G mV/G Sens Change Sens(T) @ TA > 25 C @ TA < 25 C -2 -10 - 8 0 -2 -10 - 8 0 -2 -10 - 8 0 -2 -10 - 8 0 % % VOQ Change over TA - - 35 - - 50 - - 35 - - 50 G Ratiometric Sense Change - 100 - - 100 - - 100 - - 100 - % VOQ(V) Ratiometric VOQ Change - 100 - - 100 - - 100 - - 100 - % +Lin Positive Lin 25 < 25 99 99 - 105 110 99 99 - 105 110 99 99 - 105 110 99 99 - 105 110 % -Lin Negative Lin 25 < 25 95 90 - 101 101 95 90 - 101 101 95 90 - 101 101 95 90 - 101 101 % Sym Output Symmetry 95 100 105 95 100 105 95 100 105 95 100 105 % VOQ(T) Sens(V) Note: (1) Negative current is defined as a coming out of (sourcing) the output. (2) See characteristics definitions for test conditions and calculation formulas. OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. Issue B .1 01/09 Page 2 of 4 OPTEK Technology Inc. -- 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com Ratiometric Linear Hall-effect Sensor OHN3150U, OHN3151U, OHS3150U, OHS3151U Characteristics Definitions Quiescent voltage Output: With no magnetic field present the device in the quiescent state and the voltage output is approximately equal to one-half the supply voltage (VOQ = VCC / 2) over the operating voltage and temperature range. The change in quiescent voltage output over temperature gives the device's equivalent accuracy and is specified in gauss by the calculation. VOQ (TA) - VOQ (25C) VOQ (T) = ----------------Sens (25C) Sensitivity: A magnetic south pole at, and perpendicular to, the device's symbolized package face will increase the voltage output above the quiescent value. Conversely a magnetic north pole will decrease the voltage output below the quiescent value. This change in voltage output with applied magnetic field is sensitivity and is specified in mV/G by the calculation. VO (+500G) - VO (-500G) Sens = -------------------------- 1000 The change is sensitivity over temperature is specified in percent by the calculation Sens (TA) - Sens (25C) Sens (T) = ----------------------X 100% Sens (25C) Ratiometry: The quiescent voltage output and sensitivity of these ratiometric linear Hall-effect devices are proportional to the supply voltage. The change in quiescent voltage output with supply voltage is specified in percent by the calculation VO (VCC) - VO (5V) VOQ (V) = -------------------- X 100% VCC / 5 V This change in sensitivity with supply voltage is also specified in percent by the calculation VOQ (VCC) / VOQ (5V) Sens (V) = -------------------- X 100% VCC / 5 V Linearity & Symmetry: The ability of the voltage output to vary in constant proportion to the applied magnetic field is linearity and is specified in percent by the calculation VO (+500G) - VOQ + Linearity = -------------------- X 100% 2(VO (250G) -VOQ) - Linearity = VO (-500G) - VOQ -------------------- 2(VO (-250G) -VOQ) X 100% The output is also specified in percent by the calculation VO (500G) - VOQ -------------------- X 100% - Linearity = VOQ -VOQ (-500G) OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. OPTEK Technology Inc. -- 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com Issue B.1 01/09 Page 3 of 4 Ratiometric Linear Hall-effect Sensor Emitting Diode OHN3150U, OHN3151U, OHS3150U, OHS3151U Output vs Gauss 1000 800 600 Typical Gauss 400 200 0 -200 -400 -600 -800 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 -1000 Typical Output (Volts) Icc vs Temperature 8.0 7.0 Typical Icc (mA) 6.0 5.0 4.0 3.0 2.0 1.0 0.0 -60 -40 -20 0 20 40 60 80 100 120 140 160 Temperature (C) OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible. Issue B .1 01/09 Page 4 of 4 OPTEK Technology Inc. -- 1645 Wallace Drive, Carrollton, Texas 75006 Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com