316 SS Pressure Sensor IC Sensors
Performance Specifications
MODEL 154N
Ultrastable
Connections
Ordering Information
PARAMETERS MIN TYP MAX UNITS NOTES
Full Scale Output Span 75 100 150 mV 1.2
Zero Offset -1 0 1 mV 2
Pressure Non-linearity -0.10 0.10 % Span 3
Pressure Hysteresis -0.05 0.02 0.05 % Span
Input Resistance 2000 3500 4500 Ω
Output Resistance 4000 25000 Ω
Temperature Error - Span -0.75 0.75 % Span 4
Temperature Error - Zero -0.5 0.5 % Span 4, 5
Thermal Hysteresis - Span 0.05 % Span 4
Thermal Hysteresis - Zero 0.05 % Span 4
Long Term Stability of Offset 0.1 ±% Span/yr.
Long Term Stability of Span 0.1 ±% Span/yr.
Supply Current 0.5 1.5 2.0 mA 6
Output Load Resistance 5 MΩ7
Insulation Resistance (50 VDC) 50 MΩ8
Pressure Overload 3X Rated
Compensated Operating Temperature –20°C to +85°C 9
Operating Temperature Range –40°C to +125°C 9
Storage Temperature Range –50°C to +125°C 9
Media - Pressure Port Liquids and Gases compatible with 316L Stainless Steel
Media - Reference Port Compatible with Silicon, Pyrex, Gold, Fluorosilicon Rubber and 316L Stainless Steel
Weight 24 grams 10
1. For amplified output circuits, 3.012V ± 1% interchangeability with
gainset resistor. See Application Note TN-003.
2. Measured at vacuum for absolute (A), ambient for gage (G).
3. Best fit straight line.
4. Over Temperature range: -20°C to +85°C Span with respect to +25°C.
5. 15 psi range sensors have a temperature error of ±0.75% (Max) of Zero
from -20°C to 85°C.
6. Guarantees output/input ratiometricity.
7. Load resistance to reduce measurement errors due to output loading.
8. Between case and sensing element.
9. Maximum temperature range for product with standard cable and
connector is –20°C to +105°C.
10. Weight depends upon configuration (cable, connector).
11. Standard gauge units are not recommended for vacuum applications.
For vacuum applications below 1/2 atmosphere, contact factory.
12. For pressure ranges < 15 psi, consult factory on performance
specifications.
Application Schematic
Pad. No./Cable Function
1 +OUT
2 -EX
3 +EX
4 -OUT
5 GAIN
6 GAIN
Notes
All parameters measured at 1.5mA drive and at 25°C after 10 second warm up, unless otherwise specified. Unless specifically indicated, only those
parameters indicated as tested are verified on each part. Parameters are specified for the compensated version only.