SPECIFICATION
GST40A ser ie s
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 7
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST40A05
GST40A05-P1J
GST40A07-P1J
GST40A09-P1J
GST40A12-P1J
GST40A15-P1J
GST40A18-P1J
GST40A24-P1J
GST40A48-P1J
7.5V
GST40A07
9V
GST40A09
12V
GST40A12
15V
GST40A15
18V
GST40A18
24V
GST40A24
48V
GST40A48
120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5%
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
84.5% 87.5%
7.8 ~ 10.2V
88.5%
9.4 ~ 12.2V
89.5%
12.6 ~ 16.2V
90%
15.7 ~ 20.3V
90%
18.9 ~ 24.3V
91%
25.2 ~ 32.4V
92%
50.4 ~ 64.8V
1A / 115VAC 0.5A / 230VAC
Cold start 35A / 115AC 65A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
736.4K hrs min. MIL-HDBK-217F(25℃)
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03% / ℃ (0~50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
125*50*31.5mm (L*W*H)
0.28Kg; 40pcs/12.02Kg/1.04CUFT
CONNECTOR
PLUG
CABLE See page 4~5 ; Other type available by customer requested
℃
For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
https://www.meanwell.com/serviceDisclaimer.aspx※:
OVERLOAD
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.2 ~ 6.8V
5A 5.34A 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A
0 ~ 5A 0 ~ 5.34A 0 ~ 4.45A 0 ~ 2.67A 0 ~ 2.22A 0 ~ 1.67A
0 ~ 0.84A
25W 40W 40W 40W
0 ~ 3.34A
40W 40W 40W 40W
Protection type : Shut down o/p voltage, re-power on to recover
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
50ms / 230VAC 15ms / 115VAC at full load
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
40W AC-DC Reliable Green Industrial Adaptor
See page 4~5 ther type available by customer requested; O
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
File Name:GST40A-SPEC 2020-10-20
UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS 14336-1 ,AS/NZS 60950.1,, CCC GB4943.1, PSE J62368-1
BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC62368-1 (optional) approved