MS4426
PC Board Mountable Pressure Sensor
0-100 mV Output
Voltage Excitation
Gage and Absolute
Temperature Compensated
DESCRIPTION
The MS4426 is a temperature compensated, piezoresistive silicon pressure sensor packaged in a dual-
in- line configuration and intended for cost sensitive applications where excellent performance and long-term
stability are required.
Integral temperature compensation is provided over a range of 0-50°C using laser-trimmed resistors.
The pressure sensor is available in absolute or gage pressure ranges from 0-1 to 0-300 psi. The pressure ports
are 1/8” barbed ports which mate with 3/32” ID tubing. The tube is vertically mounted to the printed circuit board.
For a horizontally mounted tube in differential, gage and absolute pressure, refer to the MS4425.
FEATURES APPLICATIONS
Dual-in-Line Package Medical Instruments
0ºC to 50ºC Compensated
Temperature Range
Altitude Measurement
Process Control
±0.15% Pressure Non Linearity Factory Automation
Solid State Reliability Leak Detection
STANDARD RANGES
Range psig psia
0 to 1
0 to 5
0 to 15
0 to 30
0 to 50
0 to 100
0 to 150
0 to 300
MS4426 www.meas-spec.com June 2011
1/5
MS4426
PERFORMANCE SPECIFICATIONS
Supply Voltage: 12V
Ambient Temperature: 25°C (un less otherwise specified)
Pressure applied to Port 2
PARAMETERS MIN TYP MAX UNITS NOTES
Span (0-1 psi) 17.6 18 18.4 mV 1
Span (0-5 psi) 58 60 62 mV 1
Span (0-15 to 0-50 psi) 88 90 92 mV 1
Span (0-100 & 0-300 psi) 98 100 102 mV 1
Span (0-150 psi) 148 150 152 mV 1
Zero Pressure Output -1 ±0.2 1 mV 1
Pressure Non Linearity -0.15 0.15 % Span 2
Pressure Hysteresis -0.20 ±0.05 0.20 % Span
Input Resistance 5 15 25 K
Output Resistance 3500 5000 6500
Temperature Error – Span -1 0.3 1 % Span 3
Temperature Error – Zero -0.75 ±0.2 0.75 mV 3
Supply Voltage 12 20 V
Long Term Stability (Offset & Span) ±0.1 mV 4
Pressure Overload 3X Rated 5
Compensated Temperature 0 50 ºC
Operating Temperature -25 85 ºC
Storage Temperature -40 125 ºC
Humidity 0 85 % RH
Weight 3 grams
Solder Temperature 260ºC Max 5 Sec. 6
Media Non-Corrosive Dry Gases Compatible with Silicon, Pyrex,
RTV, Ceramic & Gold
Notes
1. Ratiometric to supply voltage.
2. Best fit straight line. Non linearity for 5psi and 150psi devices is 0.25%
3. Maximum temperature error between 0°C and 50°C with respect to 25°C. For errors beyond the compensated temperature, see
Temperature Error Multiplier Chart below.
4. Long term stability over a one year period with constant voltage and temperature.
5. 3X or 400 psi max, whichever is less.
6. For more details refer to 4425/4426 Mounting Application Note.
MS4426 www.meas-spec.com June 2011
2/5
0.0
0.5
1.5
-25
2.0
-10 52035506580 11095 125
1.0
2.5
MS4426
DIMENSION
MS4426 www.meas-spec.com June 2011
3/5
MS4426
CONNECTIONS
PACKAGE STYLE, PINOUT, AND PORT DESIGNATION
MS4426 www.meas-spec.com June 2011
4/5
MS4426
MS4426 www.meas-spec.com June 2011
ORDERING INFORMATION
5/5
4426 - 005 G F
Model
Pressure Range
Type (A = Absolute, G = Gage)
Coating (F - Gel Fill, Blank = No Coating)
NORTH AMERICA EUROPE ASIA
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
F78340 Les Clayes-sous-Bois,
France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.