64000-0041 Manual Press
Doc. No. 64000-0041 Release Date: 09/24/02 UNCONTROLLED COPY Page 1 of 3
Revision: A Revision Date:09/24/02
Figure 3
RIBS
HOUSING ASSY
LOCKING
LATCHES
LOCKING
TABS
COVER ASSY
Figure 2
WIRE LOCAT0R
L
T
STRAIN RELIEF RIB
COVER ASSEMBLY
(BOTTOM FACING
UPWARD)
CABLE
JACKET
Operating Instruction Sheet
For 64000-0041 (Manual Press)
For SC Power Connector
Product No. 19403-0011
FEATURES
• Ratchet mechanism to insure full stroke.
• Adjustable termination height.
• Reversible for right or left hand operation.
• Dedicated tooling for quality assembly.
SCOPE
Self-Contained Power Connector Assembly for 14 AWG stranded wire. This connector is designed exclusively for Coleman
Cable E54864-H SEOPRENE 105 14 AWG 3/C SEOOW (UL) 600 V. –50°C to 105°C CSA LL39753-H STOOW (TPE).
OPERATION
1. Strip cable jacket and pre-form the wires as shown in Figure 1.
2. Position the clear cover (bottom facing upward) as shown in Figure 2.
3. Position wires into locator slots. Be certain to place black wire in slot marked BLK, green wire in slot marked GRD, and the white
wire in the third slot. Upon final positioning of all wires, be certain the end of the cable jacket is a minimum of .06” past the
second strain relief rib as shown in Figure 2.
CABLE JACKET
WHITE WIRE Figure 1
GREEN WIRE
1.00” BLACK WIRE
1.00”
Figure 4