111-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
JWS-P Series
Features
u 5 Year Warranty
u Power factor Corrected
u Approved to VDE0160 Machinery Directive
u Universal Input (85 - 265VAC)
u 200% Peak Power Capability for 10 seconds
Key Market Segments & Applications
u Factory Automation Process Control, NC-Machining, Automotive,
Packaging Equipment, Materials Handling,
Chemical Processing, Robots
u Test & Measurement Burn-in & Test, Automated Test,
Instrumentation, Measurement, Detection
Single Output Peak Power Industrial Power Supplies
Model JWS70P JWS120P JWS240P JWS480P
Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 330VDC
Inrush Current (100/200VAC) A 14 / 28 25 / 50 20 / 40
Input Current (Typ) A 1.0 / 0.5 1.6 / 0.8 3.2 / 1.6 6.4 / 3.2
Power Factor Meets EN61000-3-2
Temperature Coeffi cient <0.02%/ºC
Overcurrent Protection - >102%
Overvoltage Protection V Yes
Hold Up Time (Typ) ms 20
Leakage Current (max) mA 0.75
Remote Sense - Yes
Remote On / Off - No Yes
AC Power Fail - No Yes
Operating Temperature - -10ºC~+60ºC,derate linearly -10ºC~+65ºC, derate linearly
to 60% load from 50ºC~60ºC to 55% load from 50ºC~65ºC
Storage Temperature - -30 to +85ºC
Operating Humidity (1) - 30 - 90% RH
Storage Humidity (1) - 10 - 95% RH
Cooling - Convection Internal Fan
Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min
Isolation Resistance - >100M at 25ºC & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock - < 196.1 m/s2
Safety Agency Approvals - UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI
Conducted & Radiated EMI - EN55011 / EN55022-B, FCC Class B, VCCI-B
Weight (Typ) g 700 900 1900 3000
Recommended EMI Filter - MAW1202-22 MAW1205-22 MB1210
Size (WxHxD) mm
Warranty - Five Years
Specifi cations
(1) Non condensing
Not recommended for new designs - see HWS series