Contact Specifications
* Please refer to "●Using Micro Loads" in "Precautions" for more
information on the minimum applicable load.
Terminals/Appearances (Unit:mm) Mounting Holes (Unit: mm)
Item Model D2MV-1 models D2MV-01 models
Contact
Specification Needle Twin crossbar
Material Silver Gold alloy
Gap (standard value) 0.5 mm
Inrush
current
NC −
NO
Minimum applicable load
(reference value) * 5 VDC 30mA 5 VDC 1mA
Characteristics
Note. The data given above are initial values.
*1. The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch
Common Accessories").
*2. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel
Position value for lever. Close or open circuit of the contact is 1ms max.
Item Model D2MV-1 models D2MV-01 models
Permissible operating speed 1 mm to 1 m/s (for pin plunger models)
Permissible
operating
frequency
Mechanical 300 operations/min (for pin plunger models)
Electrical 60 operations/min
Insulation resistance 100MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value) 30 mΩ max. 50 mΩ max.
Dielectric
strength * 1
Between terminals of the same
polarity 1,000 VAC 50/60 Hz 1min
Between current-carrying metal
parts and ground 1,500 VAC 50/60 Hz 1min
Between each terminal and
non-current-carrying metal parts 1,500 VAC 50/60 Hz 1min
Vibration
resistance * 2 Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock
resistance
Durability
Models with OF of 0.10N 150 m/s2 {approx. 15G} max.
Models with OF
between 0.25 to 0.49N 400 m/s2 {approx. 40G} max.
Malfunction * 2 100 m/s2 {approx. 10G} max.
Durability * 3
Mechanical 10,000,000 operations min. (60 operations/min)
Electrical 500,000 operations min.
(30 operations/min)
1,000,000 operations min.
(30 operations/min)
Degree of protection IEC IP40
Ambient operating temperature −25°C to +80°C (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 85% max. (for +5°C to +35°C)
Weight Approx. 6g (pin plunger models)
Ratings
Note. The above rating values apply under the
following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Approved Safety Standard
UL (UL1054) /CSA (CSA C22.2 No.55)
Model D2MV-1
models
D2MV-01
models
Rated
voltage Item Resistive load
125 VAC 1A 0.1A
30 VDC 1A 0.1A
Rated
voltage Model D2MV-1 D2MV-01
125 VAC 1A 0.1A
30 VDC 1A 0.1A