B-Series B-Series CIRCUIT BREAKER Carling Technologies' B-Series hydraulic magnetic circuit breakers are specifically designed for applications requiring extra insulation and tongue and groove half-shell constructions. The B-Series carries global regulatory safety approvals for spacing requirements and are ideal for use as general purpose as well as full load amp applications. Available with various choices of time delays, terminals, actuator styles, with a wide range of standard colors and imprinting. 1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL recognized, CSA, VDE -0642, TUV, UL-1500, UL489A Listed Product Highlights: Meet CSA Standard 22.2 No. 100 for the Generator & Welder markets Extra insulation and tongue & groove half-shell constructions UL Recognized - UL Standard 508, 1077, 1500 UL Listed - UL Standard 489, 489A CSA Accepted TUV Certified VDE Certified Typical Applications: Power Supplies Medical Equipment Generators & Welders Office Equipment Control Panels Marine Military Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | B-Series Circuit Breaker - General Specifications Electrical Maximum Voltage Current Ratings 277VAC 50/60 Hz, 80VDC Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0 and 50.0 amps. Other ratings available, see ordering scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V, other ratings available, see ordering scheme. Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A 65 VDC or 0.5A 80 VDC, 0.1 Amps - 125VAC (with gold contacts). VDE-1.0 Amp - 125VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA-1500 V 50/60 Hz for one minute between all electrically isolated terminals. B-Series circuit breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) CURRENT TOLERANCE (AMPS) (%) 0.10 - 5.0 5.1 - 20.0 15 25 20.1 - 50.0 35 Pulse Tolerance Curves Mechanical Endurance Trip Free Trip Indication Physical Number of Poles Internal Circuit Config. Weight Standard Colors 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. All B-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. 1 - 6 poles at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without auxiliary switch). Approximately 65 grams/pole. (Approximately 2.32 ounces/pole.) Housing- Black; Actuator - See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition "I". Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25C to +65C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80A maximum. 3 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1O Power System. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 4 | B-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 1, except that backup fuse is limited to 80 A maximum. Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (CCN/Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1O Power System. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - General Specifications | 5 Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (CCN/ Guide DITT, File E189195), under UL489A Notes: 1 Parallel Pole Construction Table E: Lists UL Listed (489) configuration and performance capabilities as a Molded Case Circuit Breaker. B SERIES TABLE E : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION MAX. RATING FREQUENCY PHASE SERIES SHUNT TRIP DUAL COIL CURRENT RATING INTERRUPTING CAPACITY (AMPS) FULL LOAD AMPS WITHOUT BACKUP FUSE CONSTRUCTION NOTES 120 50 / 60 1 0.10 - 30 5,000 1 Pole 120 / 240 50 / 60 1 0.10 - 30 5,000 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) 120 50 / 60 1 0.10 - 30 5,000 1 Pole 120 / 240 50 / 60 1 0.10 - 30 5,000 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) CSA Accepted Component Supplementary Protector under Class 3215 30, FIle 047848 0 000 CSA Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) TUV Certified EN60934, under License No. R72103448 UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489 UL Standard 489A Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) Communications Equipment (Guide CCN/DITT, File E189195) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 6 | B-Series Circuit Breaker - Handle UL Recognized - Ordering Scheme B A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 10 5 Aux/Alarm Switch 6 Frequency & Delay 1 B 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers C 11 Agency Approval 7 CURRENT RATING (AMPERES) 1 SERIES B CODE 2 ACTUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 1 One 2 Two 450 7 Current Rating 3 4 4 CIRCUIT A 2 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) 3 D Shunt Trip (Current) E 3 Shunt Trip (Voltage) F 3 Relay Trip (Current) 5 6 Three Four G 3 Relay Trip (Voltage) H 3,4 Dual Coil with Shunt Trip Voltage Coil K 3,4 Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 5 5 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 7 2 S.P.D.T., 0.110 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 8 (Gold Contacts) 9 6 FREQUENCY & DELAY 03 2 DC 50/60Hz, Switch Only 10 6 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 6 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long Five Six S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 30 31 32 34 36 42 7 44 7 46 7 52 7 54 7 56 7 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and CSA Accepted to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, J, K, M and Q. 10 VDE Certification up to 25 amps and UL Recognition and CSA Acceptance up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 VDE Cert. available up to 12 amps. UL Rec. & CSA Acceptance available up to 30 amps. 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Acceptance, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Acceptance with Circuit Codes A, B and C. 14 Available with Actuator Codes A, S and T. 15 Available with voltage coils only. 16 Terminal Code Q not available with VDE approvals. AMPERES 020 0.020 225 0.250 420 2.000 025 0.025 230 0.300 522 2.250 030 0.030 235 0.350 527 2.750 035 0.035 240 0.400 430 3.000 040 0.040 245 0.450 435 3.500 045 0.045 250 0.500 440 4.000 050 0.050 255 0.550 445 4.500 055 0.055 260 0.600 450 5.000 060 0.060 265 0.650 455 5.500 065 0.065 270 0.700 460 6.000 070 0.070 275 0.750 465 6.500 075 0.075 280 0.800 470 7.000 080 0.080 285 0.850 475 7.500 085 0.085 290 0.900 480 8.000 090 0.090 295 0.950 485 8.500 095 0.095 410 1.000 490 9.000 210 0.100 512 1.250 495 9.500 215 0.150 415 1.500 610 10.000 220 0.200 517 1.750 710 10.500 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 8 640 8 645 8 650 8 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 A06 A12 A18 A24 J65 K20 L40 65 AC 120 AC 240 AC CODE AMPERES 6 DC 12 DC 18 DC 24 DC A32 A48 A65 J06 32 DC 48 DC 65 DC 6 AC J12 J18 J24 J48 8 TERMINAL 9 F 1 10 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 with upturned lugs G 3 11 Screw 8-32 (Bus Type) H 4 Screw 10-32 with upturned lugs J 11 Screw 10-32 (Bus Type) K 5 6 Screw 8-32 with upturned lugs L 12 & 30 bend M 11 7 Screw 8-32 (Bus Type) N & 30 bend P 13 8 Screw 10-32 with upturned lugs Q 16 & 30 bend R 9 Screw 10-32 (Bus Type) & 30 bend S 15 B Screw M5 with upturned lugs C Screw M4 with upturned lugs T E 11 Screw M4 (Bus Type) Y 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R 12 AC 18 AC 24 AC 48 AC Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect 0.250 Q.C./ Solder Lug M6 Threaded Stud Screw M4 Back Connect Printed Circuit Board Terminals Push-In Stud Screw M4 with upturned lugs & 30 bend Push-On 0.110 Tab (Q.C.) & 30 bend Screw M4 (Bus Type) & 30 bend Screw 8-32 Back Connect ON-OFF B D G J L N Q S Dual 1 2 3 4 5 6 7 8 Legend Color Black White White White White Black Black Black 10 MOUNTING / BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole 3 14 6-32 x 0.225 inches no C 14 6-32 X 0.225 inches (multi-pole units only) yes 14 4 ISO M3 x 6.5mm no D 14 ISO M3 x 6.5mm yes Front panel Snap-In, 0.75" [19.05mm] wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96" wide bezel 7 without Handleguard, 1-pole 0.96" wide; no multipole units have .105" bezel overhang on all sides 8 without Handleguard, 1-pole 0.96" wide; yes (multipole only) .105" bezel overhang on all sides 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - Handle UL489A - Ordering Scheme | 7 B A 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 4 Three Four 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 2 0 without Aux Switch 7 1 S.P.D.T., 0.093 Q.C. Term. 2 S.P.D.T., 0.110 Q.C. Term. 8 3 S.P.D.T., 0.110 Solder Lug 9 6 FREQUENCY & DELAY 4 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 54 56 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 285 290 295 410 512 415 517 420 522 527 430 435 440 445 450 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 455 460 465 470 475 480 485 490 495 610 710 611 711 612 712 8 TERMINAL 4 1 5 Push-On 0.250 Tab (Q.C.) B 2 Screw 8-32 with upturned lugs F 6 3 Screw 8-32 (Bus Type) 4 Screw 10-32 with upturned lugs G H 5 6 Screw 10-32 (Bus Type) 6 Screw 8-32 with upturned lugs J & 30 bend K 7 Screw 8-32 (Bus Type) M6 & 30 bend N 8 Screw 10-32 with upturned lugs P 7 & 30 bend Q8 9 Screw 10-32 (Bus Type) Y & 30 bend 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 7 Current Rating 1 B 1 8 Terminal 9 Actuator Color 9 ACTUATOR COLOR & LEGEND Actuator Color ON-OFF White B Black D Red G Green J Blue L Yellow N Gray Q Orange S 1 SERIES B 3 POLES 2 1 One 2 Two 450 613 614 615 616 617 618 620 622 624 625 630 635 3 640 3 645 3 650 3 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 45.000 50.000 Screw M5 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect M6 Threaded Stud Screw M4 Back Connect Printed Circuit Board Terminals Push-In Stud Screw 8-32 Back Connect 10 Mounting/ Barriers Dual 1 2 3 4 5 6 7 8 M T 11 Max. Appl. Rating 12 Agency Approval Legend Color Black White White White White Black Black Black 10 MOUNTING / BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches (multi-pole units only) yes 2 ISO M3 x 5mm no B ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole 3 6-32 x 0.225 inches no C 6-32 X 0.225 inches (multi-pole units only) yes 4 ISO M3 x 6.5mm no D ISO M3 x 6.5mm yes Front panel Snap-In, 0.75" [19.05mm] wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96" wide bezel 7 without Handleguard, 1-pole 0.96" wide; no multipole units have .105" bezel overhang on all sides 8 without Handleguard, 1-pole 0.96" wide; yes (multipole only) .105" bezel overhang on all sides 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 4 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, J, K, M and Q. 5 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 6 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 7 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 8 Terminal Code Q not available with VDE approvals. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 8 | B-Series Circuit Breaker - Handle UL489 Listed - Ordering Scheme B A 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 2 33 Two Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 4 0 without Aux Switch 1 S.P.D.T., 0.093 Q.C. Term. 2 S.P.D.T., 0.110 Q.C. Term. 3 8 9 6 FREQUENCY & DELAY 21 AC Ultra Short 22 AC Short 24 AC Medium 26 AC Long S.P.D.T., 0.110 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 42 44 46 7 Current Rating 1 B A 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 9 ACTUATOR COLOR & LEGEND 6 Actuator Color ON-OFF Dual White B 1 Black D 2 Red G 3 Green J 4 Blue L 5 Yellow N 6 Gray Q 7 Orange S 8 1 SERIES B 3 POLES 2 1 One 450 AC, Short,Hi-Inrush AC, Medium, Hi-Inrush AC, Long, Hi-Inrush K G 11 Max. Appl. Rating 12 Agency Approval Legend Color Black White White White White Black Black Black 10 MOUNTING / BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole 7 C 6-32 X 0.225 inches (multi-pole units only) yes D ISO M3 x 6.5mm yes Front panel Snap-In, 0.75" [19.05mm] wide bezel 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96" wide bezel 8 without Handleguard, 1-pole 0.96" wide; yes (multipole only) .105" bezel overhang on all sides 11 MAXIMUM APPLICATION RATING C 8 120/240VAC K 120VAC 7 CURRENT RATING (AMPERES) CODE 210 215 220 225 230 235 240 245 250 255 260 265 270 275 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 280 285 290 295 410 512 415 517 420 522 527 430 435 440 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 445 450 455 460 465 470 475 480 485 490 495 610 710 611 A 8 TERMINAL 4 1 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 with upturned lugs B 3 Screw 8-32 (Bus Type) F 4 Screw 10-32 with upturned lugs 5 Screw 10-32 (Bus Type) G 6 Screw 8-32 with upturned lugs H & 30 bend J 7 Screw 8-32 (Bus Type) K & 30 bend M 8 Screw 10-32 with upturned lugs N & 30 bend Q 9 Screw 10-32 (Bus Type) Y & 30 bend 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 711 612 712 613 614 615 616 617 618 620 622 624 625 630 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 Load Terminal #8 Screw with QC Combination (Special Catalog #) Screw M5 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect M6 Threaded Stud Screw M4 Back Connect Push-In Stud Screw 8-32 Back Connect 12 AGENCY APPROVAL G UL489 Listed 3 UL489 Listed, TUV Certified Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 All poles must be same polarity. 3 3 pole units available only when 1 of 3 poles is neutral. 4 Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Standard actuator colors are black and white. 7 Adapter plate with mounting centers of 2.082 inches. Available with Actuator Codes A, S and T. 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - Handle - Circuit & Terminal Diagrams | 9 Circuit & Terminal Diagrams: in. [mm] SERIES TRIP (2 TERM'S.) ANSI LINE (NETZ) LINE IEC SERIES TRIP LINE MAIN TERM'S. (SEE TABLE A) A CIRCUIT CODE AUX SWITCH CODE CIRCUIT SCHEMATIC CIRCUIT CODE AUX SWITCH CODE CIRCUIT SCHEMATIC ANSI IEC SWITCH ONLY (NO COIL) LINE (3) (NETZ) O B C O B C 2 3 4 H 0 K 0 I> LOAD (LAST) LOAD 1.730 [43.94] LOAD LOAD (LAST) SERIES TRIP WITH AUXILIARY / ALARM SWITCH SWITCH ONLY (NO COIL) WITH AUXILIARY SWITCH .520 [13.21] SERIES TRIP W AUX SWITCH (5 TERM'S.) NO NC C NO NO A 2 3 4 LINE LINE (NETZ) LOAD (3) SHUNT (NEBENSCHLUSS) D E 1 3 LINE (NETZ) LINE F G 4 4 RELAY (RELAIS) RELAY STANDARD C/B HANDLE POSITION 1 VOLTAGE COIL 3 2 4 LOAD (LAST) HANDLE POSITION 4 MID TRIP C/B ALARM SWITCH MODE HANDLE POSITION 30 30 I> LOAD (LAST) LOAD MID TRIP C/B AUX. SWITCH MODE AUX. SWITCH MODE (w/o ALARM SWITCH) 30 OFF F O OF NC NO C F O OF NC NO C F O OF I NC NO C NC NO C NC NO C ON ON ON I I ON 30 NC NO 30 ELECTRICAL TRIP F O OF 30 C MID TRIP NC NO C NC NO 30 C 90 MID TRIP NC NO VOLTAGE COIL C VOLTAGE COIL 2 0 HANDLE POSITION VS. AUX/ALARM SWITCH MODE CIRCUIT BREAKER MODE LINE (NETZ) 1 1 I> 3 .390 [9.91] LOAD (LAST) U> DUAL COIL; SERIES TRIP CURRENT COIL, RELAY TRIP VOLTAGE COIL LINE (3) (NETZ) LOAD 3 I> 2 RELAY 4 LOAD (LAST) LOAD 2 2 NC ALARM SWITCH VOLTAGE COIL RELAY (RELAIS) 1 .780 [19.81] I> 0 RELAY TRIP RELAY TRIP (4 TERM'S.) NO LINE LOAD (LAST) LINE NO LOAD I> .390 [9.91] C DUAL COIL; SERIES TRIP CURRENT COIL, SHUNT TRIP VOLTAGE COIL SHUNT TRIP (3 TERM'S.) SHUNT C ALARM SWITCH SHUNT TRIP (3) STD. AUX. SWITCH NC NC LOAD (LAST) LOAD LINE (NETZ) STD. AUX. SWITCH C NC AUX. SWITCH TERM'S. LINE LINE (NETZ) LINE C 90 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com U> 3 VOLTAGE COIL 10 | B-Series Circuit Breaker - Handle - Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] TERMINAL DIMENSIONAL DETAIL & RATING .360[9.14] .392[9.96] .250[6.35] .375[9.53] .069[1.75] DIA TAB (Q.C.) .250[6.35] .093DIA [.76] #8-32 30 AMP #10-32 50 AMP #8-32 30 AMP #10-32 30 AMP M5 30 AMP M4 30 AMP +.002 -.000 .405[10.29] BACK CONNECT 30 AMP M6 STUD #8-32 30 AMP #10-32 50 AMP M5 50 AMP M4 30 AMP .161 DIA [O 4.10] .051 DIA[O1.29] .110 [2.80] .087 [2.20] PUSH-IN STUD .110 [2.80] .126 [3.20] .287 [7.29] MATING HOLE TAB (Q.C.) .070 DIA [O1.80] SOLDER TYPE 1.313 [33.35] 2.230 [56.64] TYP .154 [3.91] DIA PUSH-IN STUD 50 AMP TABLE A TIGHTENING TORQUE SPECIFICATIONS THREAD SIZE #6-32 & M3 MOUNTING HARDWARE #8-32 & M4 THREAD TERMINAL SCREW #10-32 & M5 THREAD TERMINAL SCREW TORQUE 7-9 IN-LBS [0.8-1.0 NM] 12-15 IN-LBS [1.4-1.7 NM] 15-20 IN-LBS [1.7-2.3 NM] .520 [13.21] LINE LINE 2.000 [50.80] LOAD LOAD TABLE B TERMINAL DESCRIPTION TAB (Q.C.) MAIN SCREW TYPE SHUNT, RELAY TAB (Q.C.) & SCREW #8-32 DUAL COIL W/UPTURNED LUGS TAB (Q.C.) .110 x .020 AUX. SWITCH* SOLDER TYPE DEPTH BEHIND PANEL 2.090 [53.09] 2.122 [53.90] 2.612 [66.35] 2.644 [67.16] 2.537 [64.44] 2.348 [59.64] * AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS. .875 [22.23] REF BARRIER FOR UL-489 MULTI-POLE BREAKERS BARRIER FOR UL-RECOGNIZED MULTI-POLE BREAKERS SEE TABLE-B DEPTH BEHIND PANEL WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFICATION SCHEME. .393 [9.96] REF LINE (NETZ) ON I MID TRIP .100 [2.54] .750 [19.05] 50 AMP AUXILIARY SWITCH TERMINAL DETAIL [+.05] [-.00] .392 [9.97] CENTERLINE OF PUSH-IN STUD CONTACT AREA .750[19.05] .437 [11.10] QC SOLDER LUG BUS 1.000 [25.40] .205 [5.21] .344[8.74] .375[9.53] UPTURN LUG 30 AMP .392[9.96] 1.560 [39.62] TYP 1.936[49.17] OFF O 30 1.350 [34.29] 2 PLCS 1.560 [39.62] TYP LOAD (LAST) .032 [.81] TYP .220 [5.59] TYP PUSH-IN STUD M6 STUD SCREW TERMINAL WITH 30 BEND 1.250 [31.75] BACK CONNECT SCREW TERMINAL BACK CONNECT SCREW TERMINAL WITH RETAINER Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - Handle - Dimensional Specifications | 11 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance 0.20 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 12 | B-Series Circuit Breaker - Handle - Front Panel Snap-in Mounting Style 5 - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - Handle - Front Panel Snap-In Mounting Style 7 - Dimensional Specifications | 13 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 14 | B-Series Circuit Breaker - Rocker UL489 Listed - Ordering Scheme B F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES B 2 ACTUATOR Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend 630 7 Current Rating 2 3 A 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 5 1 6 Push-On 0.250 Tab (Q.C.) B 2 Screw 8-32 with upturned lugs C 3 Screw 8-32 (Bus Type) F 4 Screw 10-32 with upturned lugs 5 Screw 10-32 (Bus Type) G 6 Screw 8-32 with upturned lugs H & 30 bend J 7 Screw 8-32 (Bus Type) K & 30 bend N 8 Screw 10-32 with upturned lugs Y & 30 bend 9 Screw 10-32 (Bus Type) & 30 bend K G 11 Max. Appl. Rating 12 Agency Approval Screw M5 with upturned lugs Screw M4 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect Screw M4 Back Connect Screw 8-32 Back Connect 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 7 ON-OFF Dual 7 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 3 POLES 1,2 1 One 2 33 Two Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 4 0 without Aux Switch 7 1 S.P.D.T., 0.093 Q.C. Term. 2 S.P.D.T., 0.110 Q.C. Term. 8 3 S.P.D.T., 0.110 Solder Lug 9 6 FREQUENCY & DELAY 21 AC Ultra Short 22 AC Short 24 AC Medium 26 AC Long 42 44 46 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. AC, Short,Hi-Inrush AC, Medium, Hi-Inrush AC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 415 517 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 495 610 710 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 9.500 10.000 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 10 MOUNTING / BARRIERS MOUNTING STYLEBARRIERS 9 Threaded Insert, 2 per pole A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes ROCKERGUARD BEZEL Threaded Insert, 2 per pole C 6-32 X 0.225 inches (multi-pole units only) yes D ISO M3 x 6.5mm yes 11 MAXIMUM APPLICATION RATING C 8 120/240 VAC K 120 VAC 12 AGENCY APPROVAL G UL489 Listed 3 UL489 Listed, TUV Certified Notes: 1 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 2 All poles must be same polarity. 3 3 pole units available only when 1 of 3 poles is neutral. 4 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20 amps. 7 Dual legend = ON-OFF/I-O 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - Flat Rocker UL489 Listed - Ordering Scheme | 15 B 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES B 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 630 7 Current Rating 2 3 A 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL 6 1 7 Push-On 0.250 Tab (Q.C.) B 2 Screw 8-32 with upturned lugs C 3 Screw 8-32 (Bus Type) F 4 Screw 10-32 with upturned lugs 5 Screw 10-32 (Bus Type) G 6 Screw 8-32 with upturned lugs H & 30 bend J 7 Screw 8-32 (Bus Type) K & 30 bend N 8 Screw 10-32 with upturned lugs Y & 30 bend 9 Screw 10-32 (Bus Type) & 30 bend K G 11 Max. Appl. Rating 12 Agency Approval Screw M5 with upturned lugs Screw M4 with upturned lugs Screw M5 with upturned lugs & 30 bend Screw M5 (Bus Type) & 30 bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect Screw M4 Back Connect Screw 8-32 Back Connect 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color Visi-Color 8 ON-OFF Dual 8 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 3 POLES 2,3 1 One 2 34 Two Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 4 0 without Aux Switch 7 1 S.P.D.T., 0.093 Q.C. Term. 2 S.P.D.T., 0.110 Q.C. Term. 8 3 S.P.D.T., 0.110 Solder Lug 9 6 FREQUENCY & DELAY 21 AC Ultra Short 22 AC Short 24 AC Medium 26 AC Long 42 44 46 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. AC, Short,Hi-Inrush AC, Medium, Hi-Inrush AC, Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 095 210 215 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 415 517 420 522 527 430 435 440 445 450 455 460 465 470 475 480 485 490 1.500 1.750 2.000 2.250 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 495 610 710 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 9.500 10.000 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 10 MOUNTING / BARRIERS 9 STANDARD ROCKER BEZEL BARRIERS 12 Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes 10 RECESSED OFF SIDE ROCKER ACTUATOR E 6-32 X 0.225 inches (multi-pole units only) yes F ISO M3 x 6.5mm yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole C 6-32 x 0.195 inches yes D ISO M3 x 5mm yes 11 MAXIMUM APPLICATION RATING C 11 120/240 VAC K 120 VAC 12 AGENCY APPROVAL G UL489 Listed 3 UL489 Listed, TUV Certified Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 All poles must be same polarity. 4 3 pole units available only when1 of 3 poles is neutral. 5 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Screw Terminals are recommended on ratings greater than 20 amps. 7 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20 amps. 8 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 9 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 10 Recessed "off-side" available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. 11 Voltage rating available with 2 & 3-pole breakers only. 12 Barriers supplied on multi-pole units only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 16 | B-Series Circuit Breaker - Rocker UL489 Listed - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate "OFF" is opposite of indicate "ON". 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 All dimensions are in inches [millimeters]. 4 Tolerance .020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com B-Series Circuit Breaker - Flat Rocker UL489 Listed - Dimensional Specifications | 17 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 Tolerance .010 [.25] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com 18 | B-Series Circuit Breaker - PC Terminal Diagrams PC Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90. 3 Tolerance .010 [.25] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com Sales Representatives, Distributors & Company Profile | 19 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling's environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 Fax: (860) 793-9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: sales@carlingtech.com Northern Region Sales Office: nrsm@carlingtech.com Southeast Region Sales Office: sersm@carlingtech.com Midwest Region Sales Office: mrsm@carlingtech.com West Region Sales Office: wrsm@carlingtech.com Latin America Sales Office: larsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China: shenzhen@carlingtech.com Shanghai, China: shanghai@carlingtech.com Pune, India: india@carlingtech.com Kaohsiung, Taiwan: taiwan@carlingtech.com Yokohama, Japan: japan@carlingtech.com Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: ltd.sales@carlingtech.com Germany: gmbh@carlingtech.com France: sas@carlingtech.com www.carlingtech.com REV_06_2017 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Carling Technologies: BB3-X0-14-635-1G1-C BA1-B0-44-430-122-D BA2-B0-44-615-122-D BA1-B0-34-615-1A1-C BA3-X0-01-772-X22-D BA1-B0-10-430-1B1-C BA1-B0-10-612-1B1-C BA2-B0-24-624-C32-D BA1-B2-26-620-5A1D BA3-B2-26-620-5A1D BA3-B2-26-630-5A1D BA3-X0-04-129-221-D BA2-B0-10-210-1B1-C BA2-X0-19-005-522-D BA2-B0-16-630-222-D BA1-B0-22-455-211-D BA1-B0-52-455-411-D BA2-B0-44-630-111-C BB2-B8-22-650-521-C BA3-B0-22-615-111-B BA2-B0-24-612-411-D BA3-B0-22-630-211-D BA2-B0-24-616-M22-D BA2-B0-46-615-121-D BB2-B0-22-650-521-C BA2-B0-44-615-111-D BA2-B2-26-620-12A-D BB2-B2-24-620-521-C