Control Gear
2/1
ABB LIMITED
Contents
3 Pole Contactors.......................................................................... 2-2
4 Pole Contactors.......................................................................... 2-20
Mini Contactors.............................................................................. 2-37
Manual Motor Starters .................................................................. 2-42
Field Bus Plugs.............................................................................. 2-49
Softstarters.................................................................................... 2-54
Pilot Devices.................................................................................. 2-58
Switching Power Supplies (CP Range) .......................................... 2-72
Return to main index
A9-30-10 A26-30-10
a.c. Control circuit supply Types A12-30-10 A30-30-10
A16-30-10 A40-30-10
a.c.
& Control circuit supply Types
d.c. (Electronic coil interface)
AE9-30-00 AE26-30-00
d.c. Control circuit supply Types AE12-30-00 AE30-30-00
AE16-30-00 AE40-30-00
1 x N.C.1 x N.O.
CA 5-10 1-pole, front mounting CA 5-01
1-pole, front m
AC-1 utilization category
When making,
the switched-on
current is equal to
the Inload rated
current with
cos ϕ 0.95.
AC-3 utilization category
When making,
the motor current is
about 6 x In.
Breaking while the
motor is running at
Inmotor F.L.C.
A.., AF.., 3-pole Contactors
RV 5
RC 5-1
VE 5-1
VM 5-1
TP 40 DA, TP 180 DA Direct timing - Front mounting TP 40 I
TE5S Direct timing - Indep
&
setting
range in
Amps
Auxiliary CA 5-.., 1-pole Types
contacts CAL 5-.., 2-pole
Timers TP.., Pneumatic Types
TE.., Electronic
Supply voltages: 24 V a.c./d.c.,
110 ... 120; 220 ... 240; 380 ... 440 V a.c.
Interlocks VE 5-., Mechanical / Electrical Types
VM..., Mechanical
mounting between 2 contactors
Surge RV.., (Varistor) a.c./d.c. Types
suppressors RC.., (Capacitor) a.c.
O/L relays TA..DU.., Thermal O/L relay Types
E..DU.., Electronic O/L relay
Standard starting time 2 ... 10 s
tripping class 10 A
Selection & Ordering
Select accessory type and
quote required data in plain
text.
Selection & Ordering
Select O/L relay type and
setting range according to
motor F.L.C.
Selection & Ordering
Select contactor type.
Select contactor coil voltage on cover folding
page 0/1, according to control circuit supply.
(Please quote coil voltage in plain text).
a.c. Circuit Switching
3-pole contactors
Contactor Main
Accessories
Protection of
3-phase motors
TA 25 DU...
0.10...0.16
0.16...0.25
0.25...0.40
0.40...0.63
0.63...1.0
22...32
29...42
TA 42 DU...
13...19
18...25
24...32
3.5...5.0
4.5...6.5
6.0...8.5
7.5...11
10...14
1.0...1.4
1.3...1.8
1.7...2.4
2.2...3.1
2.8...4.0
A9 A12 A16 A26 A30 A40
Switching of 3-phase Cage Motors
AC-3 Power < 55 °C, 400 V kW 4 5.5 7.5 11 15 18.5
rating
Rated < 55 °C, 400 V A9 12 17 26 32 37
AC-3 operational < 55 °C, 415 V A9 12 17 26 32 37
current < 55 °C, 690 V A7 9 10 17 21 25
Switching of Resistive Circuits
Rated < 40 °C A25 27 30 45 55 60
AC-1 operational < 55 °C A22 25 27 40 55 60
current < 70 °C A18 20 23 32 39 42
lWith conductor cross-sectional area mm22.5 4 4 6 10 16
lRated operational voltage V690
ABB LIMITED 2/2
Please consult us for electronic solution
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
A50-30-00 A95-30-00 A145-30-11 A210-30-11
A63-30-00 A110-30-00 A185-30-11 A260-30-11
A75-30-00 A300-30-11
AF50-30-00 AF95-30-00 AF145-30-11 AF210-30-11 AF400-30-11 AF 580-30-11
AF63-30-00 AF110-30-00 AF185-30-11 AF260-30-11 AF 460-30-11 AF 750-30-11
AF75-30-00 AF300-30-11
1 x N.O. + 1 x
N.C.
1 x N.O. + 1 x
N.C.
1 x N.O. + 1 x
N.C.
CAL 5-11 2-pole, side mounting
bar / mm
VM 750H
VM 300H
VE 5-2
RC 5-2
The built-in coil interface eliminates the need of extra
surge suppressors on these sizes
RV 5
RC 5-2
TE5S
Independent mounting
TE5S Direct timing - Independent mounting
AInverse timing - Front mounting
ng
CAL 5-11 2-pole, side mounting CAL 5-11 B
(1st block) (2nd block)
100...320
E 320 DU
60...200
E 200 DU
250...800
E 800 DU
150...500
E 500 DU
A50 A63 A75 A95 A110 A145 A185 A210 A260 A300 AF400 AF460 AF580
AF750
22 30 37 45 55 75 90 110 140 160 200 250 315 400
50 65 75 96 110 145 185 210 260 305 400 460 580 750
50 65 75 96 110 145 185 210 260 300 400 460 580 750
35 43 46 65 82 120 170 210 220 280 350 400 500 650
100 115 125 145 160 250 275 350 400 500 600 700 800 1050
85 95 105 135 145 230 250 300 350 400 500 600 700 800
70 80 85 115 130 180 180 240 290 325 400 480 580 720
35 50 50 50 70 120 150 185 240 300 2 x 185 2 x 240 2 x 240 2 x 80 x 5
1000 690
ABB LIMITED 2/
65...90
80...110
165...235
220...310
TA 450 DU...
130...175
150...200
TA 200 DU...
60...8029...42
36...52
45...63
60...80
TA 80 DU...TA 75 DU...
TA 110 DU...
Please consult us for thermal solution
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/4
A 9 ... A 110 3-pole Contactors
a.c. Operated
Location of surge suppressors.
Clear marking of coil voltages and
frequencies.
Connecting point for control leads in top
part of main terminals of A 50 ... A 110
contactors.
Terminal marking according to
IEC 60947-4-1, EN 50005, EN 50012 and
NEMA standards.
Location of function marker.
Stops for attaching front-mounted
accessories.
Terminal screws:
A 9 ... A 16 contactors:
M3.5 Pozidriv (+,-) No.2 for all terminals,
A 26 contactors:
M4 Pozidriv (+,-) No.2 for main and
auxiliary terminals,
M3.5 Pozidriv (+,-) No.2 for coil terminals,
A 30, A 40 contactors:
M5 Pozidriv (+,-) No.2 for main terminals,
M3.5 Pozidriv (+,-) No.2 for auxiliary and
coil terminals,
A 50 ... A 75 contactors:
M6 Pozidriv (+,-) No.2 for main terminals,
M3.5 Pozidriv (+,-) No.2 for coil terminals,
A 95 ... A 110 contactors:
M8 Hexagon socket (s = 4 mm) for main
terminals,
M3.5 Pozidriv (+,-) No.2 for coil terminals.
Terminals delivered in open position with
captive screws.
Screwdriver guidance for all terminals.
Degree of protection (IP...) of terminals
according to IEC 60947-1:
A 9 ... A 40 contactors:
IP 20 for main and auxiliary terminals.
A 50 ... A 110 contactors:
IP 10 for main terminals,
IP 20 for auxiliary terminals.
Holes for screw fixing (screws not supplied).
Distance between holes according to
EN 50003 (contactors for motors 11 kW).
Location of side-mounted accessories
(on right or left hand side).
Quick fixing on mounting rail according
to IEC 715, EN 50022 and EN 50023
standards:
35 x 7.5 mm for A 9 ... A 40 contactors,
35 x 15 mm for A 9 ... A 75 contactors,
75 x 25 mm for A 50 ... A 110 contactors.
Application
A 9 ... A 110 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V a.c. / 1000 V a.c.
or 220 V d.c. / 440 V d.c. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting.
Description
The A... series 3-pole contactors are of the block type design.
Main poles and auxiliary contact blocks
A 9 ... A 40 1-stack contactors:
- 3 main poles,
- 1 built-in auxiliary contact,
-front and side mounted add-on auxiliary contact blocks.
A 50 ... A 110 contactors:
- 3 main poles,
-front and side mounted add-on auxiliary contact blocks.
Control circuit: a.c. operated with laminated magnet circuit
Accessories: a wide range of accessories is available
Variants
4-pole: A 9 ... A 75 contactors (with 4 N.O. or 2 N.O. + 2 N.C. main poles).
a.c./d.c. operated controlled supply: AF 50 ... AF 110 contactors.
d.c. operated: AE 9 ... AE 40 contactors.
d.c. operated with large coil voltage range: TAE 50 ... TAE 110 contactors (on application).
contactors for capacitor switching (UA..., UA..-R types),
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
Rated operational Auxiliary contacts Weight Footprint Order Code
current fitted kg H W D
1st stack
AC-3 AC-1
400 V 40 °C state coil voltage
A A KW (see table below)
1 - 0.34 74 44 74 A9.30.10
9 25 4 - 1 0.34 A9.30.01
1 - 0.34 74 44 74 A12.30.10
12 27 5.5 - 1 0.34 A12.30.01
1 - 0.34 74 44 74 A16.30.10
17 30 7.5 - 1 0.34 A16.30.01
1 - 0.60 90 54 94 A26.30.10
26 45 11 - 1 0.60 A26.30.01
1 - 0.71 90 54 108 A30.30.10
32 55 15 - 1 0.71 A30.30.01
1 - 0.71 90 54 108 A40.30.10
37 60 18.5 - 1 0.71 A40.30.01
50 100 22 1 1 1.20 110 82 108 A50.30.11
65 115 37 1 1 1.20 110 82 108 A63.30.11
75 125 40 1 1 1.20 110 82 108 A75.30.11
96 145 45 1 1 2.04 148 102 124 A95.30.11
110 160 55 1 1 2.04 148 102 124 A110.30.11
ABB LIMITED 2/5
A 9 ... A 110 3-pole Contactors
a.c. Operated
A95-30-11
A50-30-11
A26-30-10
A9-30-10
Coil voltages
Voltage Voltage
V - 50Hz V - 60Hz
24 24
48 48
110 110 ... 120
220 ... 230 230 ... 240
230 ... 240 240 ... 260
380 ... 400 400 ... 415
400 ... 415 415 ... 440
Other voltages on application
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/6
A 9 ... A 110 3-pole Contactors
Main Accessories
CA 5-10 CAL 5-11
RC 5-1/50RV 5/50
VE 5-1
TP 40 DA
TE5S-240
Auxiliary Contact Blocks
Mounting on Positioning Contacts Weight Order code
contactors kg
A 9 ... A 110 Front face 1 0.014 CA 5-10
1 0.014 CA 5-01
A 9 ... A 40 Front face 3 1 0.060 CA 5-31 M
2 2 0.060 CA 5-22 M
A 9 ... A 110 Side 1 1 0.050 CAL 5-11
Pneumatic Timers
Mounting on Timing range Contacts Weight Order code
contactors kg
Direct 0.1 ... 40 s 1 1 0.070 TP 40 DA
A 9 ... A 75 Direct 10 ... 180 s 1 1 0.070 TP 180 DA
Inverse 0.1 ... 40 s 1 1 0.070 TP 40 IA
Inverse 10 ... 180 s 1 1 0.070 TP 180 IA
Electronic Timers for star-delta starters (dwelling time 50 ms)
Mounting Timing range Supply voltage Weight Order code
V kg
Independent Direct 24 a.c. / d.c. 0.080 TE5S-24
0.8 ... 8 s 110 ... 120 a.c. 0.080 TE5S-120
or 220 ... 240 a.c. 0.080 TE5S-240
6 ... 60 s 380 ... 440 a.c. 0.080 TE5S-440
Interlocks
Mounting on Feature Contacts Weight Order code
contactors kg
A 9 ... A 40 Mech. / electrical 2 0.076 VE 5-1
A 50 ... A 110 2 0.146 VE 5-2
A 9 ... A 40 Mechanical 0.066 VM 5-1
Note: Use type VE 5-2 for mechanical and electrical interlocking between A 40 and A 50 contactors.
Surge Suppressors
Mounting on Feature Voltage range Weight Order code
contactors kg
24 ... 50 V a.c./d.c. 0.015 RV 5/50
A 9 ... A 110 Varistor 50 ... 133 V a.c./d.c. 0.015 RV 5/133
110 ... 250 V a.c./d.c. 0.015 RV 5/250
250 ... 440 V a.c./d.c. 0.015 RV 5/440
24 ... 50 V a.c. 0.012 RC 5-1/50
A 9 ... A 40 RC 50 ... 133 V a.c. 0.012 RC 5-1/133
110 ... 250 V a.c. 0.012 RC 5-1/250
250 ... 440 V a.c. 0.012 RC 5-1/440
24 ... 50 V a.c. 0.015 RC 5-2/50
A 50 ... A 110 RC 50 ... 133 V a.c. 0.015 RC 5-2/133
110 ... 250 V a.c. 0.015 RC 5-2/250
250 ... 440 V a.c. 0.015 RC 5-2/440
Other Accessories
A wide range of accessories are available:
various auxiliary contact blocks for specific controls and use,
interface relays,
connecting auxiliaries: strips, connectors, additional pieces, etc.
impulse contact blocks, lamp holder and fuse holder blocks,
function marker.
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
A 9 ... A 110 3-pole Contactors
Thermal O/L Relays
ABB LIMITED 2/7
TA 110 DU
TA 80 DU
TA 75 DU
TA 42 DU
TA 25 DU
Thermal O/L Relays, Class 10A
For Setting range Weight Order code
contactors: kg
0.10 ... 0.16 0.150 TA 25 DU 0.16
0.16 ... 0.25 0.150 TA 25 DU 0.25
0.25 ... 0.40 0.150 TA 25 DU 0.4
0.40 ... 0.63 0.150 TA 25 DU 0.63
0.63 ... 1.00 0.150 TA 25 DU 1.0
1.0 ... 1.4 0.150 TA 25 DU 1.4
1.3 ... 1.8 0.150 TA 25 DU 1.8
1.7 ... 2.4 0.150 TA 25 DU 2.4
A 9 ... A 30 2.2 ... 3.1 0.150 TA 25 DU 3.1
2.8 ... 4.0 0.150 TA 25 DU 4.0
3.5 ... 5.0 0.150 TA 25 DU 5.0
4.5 ... 6.5 0.150 TA 25 DU 6.5
6.0 ... 8.5 0.150 TA 25 DU 8.5
7.5 ... 11 0.150 TA 25 DU 11
10 ... 14 0.150 TA 25 DU 14
13 ... 19 0.150 TA 25 DU 19
18 ... 25 0.150 TA 25 DU 25
24 ... 32 0.170 TA 25 DU 32
18 ... 25 0.330 TA 42 DU 25
A 30 ... A 40 22 ... 32 0.330 TA 42 DU 32
29 ... 42 0.330 TA 42 DU 42
18 ... 25 0.330 TA 75 DU 25
22 ... 32 0.330 TA 75 DU 32
29 ... 42 0.330 TA 75 DU 42
A 50 ... A 75 36 ... 52 0.330 TA 75 DU 52
45 ... 63 0.330 TA 75 DU 63
60 ... 80 0.330 TA 75 DU 80
29 ... 42 0.360 TA 80 DU 42
36 ... 52 0.360 TA 80 DU 52
45 ... 63 0.360 TA 80 DU 63
A 95 ... A 110 60 ... 80 0.360 TA 80 DU 80
65 ... 90 0.750 TA 110 DU 90
80 ... 110 0.750 TA 110 DU 110
Separate Mounting Kit
For O/L relays: Weight Order code
kg
TA 25 DU 25 0.050 DB 25/25 A
TA 25 DU 32 0.075 DB 25/32 A
TA 42 DU, TA 75 DU, TA 80 DU 0.170 DB 80
TA 110 DU 0.230 DB 200
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/8
A 145 ... AF 750 3-pole Contactors
a.c. Operated - A 145 ... A 300 Contactors
a.c. / d.c. Operated - AF 400 ... AF 750 Contactors
Application
A 145 ... AF 750 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V a.c. or
220 V d.c. / 600 V d.c. The contactors can also be used for many other applications such as isolation, bypass, capacitor switching, lighting...
Description
The A 145 ... AF 750 3-pole contactors are of the block type design.
Main poles and auxiliary contact blocks
3 main poles,
1 N.O. and 1 N.C. auxiliary contact block (fitted on the left side).
A maximum of 4 auxiliary contact blocks can be fitted on each contactor.
Control circuit:
A 145 ... A 300 contactors: a.c. operated with laminated magnet circuit,
AF 400 ... AF 750 contactors: a.c. operated, large voltage range, with electronic coil interface, with laminated magnet circuit.
Contactors AF 400 ... AF 750 are fitted as standard with an electronic coil interface which accepts a wide control voltage range
for a.c. 50/60 Hz supply or d.c. supply.
Accessories: a wide range of accessories is available.
Variants next pages in this section
a.c./d.c. operated, large voltage range, with electronic coil interface: AF 145 ... AF 300 contactors.
A 1 4 5 . . . A300 contactors main
terminals in line with Isomax circuit
breakers.
Location of side-mounted mechanical
interlock (on right or left hand side).
CAL 5-11 side mounted auxiliary contact
block.
Easy access to the terminals.
Main terminals.
Screws and nut insert holders are included.
Screw fixing, top and bottom.
(Screws supplied).
Terminal shrouds for protection can easily
be fitted from the front.
Location of surge suppressors on
A 145 ... A 300 contactors.
(built-in on AF 400 ... AF 750 contactors).
Quick release quarter turn screws for
easy access to contact inspection.
Terminal markings according to
IEC 60947-4-1, EN 50005, EN 50012
and NEMA standards.
Easy access to the coil terminals.
Clear marking of coil voltages and
frequencies.
Front access to the coil, no need to
remove power cables when changing coil.
On-Off position indicator.
Location of function marker.
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
A 145 ... AF 750 3-pole Contactors
a.c. Operated - A 145 ... A 300 Contactors
a.c. / d.c. Operated - AF 400 ... AF 750 Contactors
ABB LIMITED 2/9
AF 460-30-11
A 300-30-11
A 145-30-11
Coil voltages
Voltage Voltage
V - 50Hz V - 60Hz
24 24
48 48
110 110 ... 120
220 ... 230 230 ... 240
230 ... 240 240 ... 260
380 ... 400 400 ... 415
400 ... 415 415 ... 440
Other voltages on application
Coil voltages: AF 400 …AF 750
Voltage Voltage
V - 50/60Hz V d.c.
- 24 … 60
48 … 130 48 … 130
100 … 250 100 ... 250
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
AF... contactors with electronic coil interface: electromagnetic compatibility and A or B environment definitions + page ????
AF 750-30-11
Rated operational Auxiliary contacts Footprint Weight Order code
current fitted kg
AC-3 AC-1
400 V 40 °C H W D state coil voltage
A A (see table below)
145 250 1 1 196 112 160 3.500 A 145-30-11
185 275 1 1 196 112 160 3.500 A 185-30-11
210 350 1 1 227 140 181 6.100 A 210-30-11
260 400 1 1 227 140 181 6.100 A 260-30-11
305 500 1 1 227 140 181 6.100 A 300-30-11
400 600 1 1 278 186 216 12.00 AF 400-30-11
460 700 1 1 278 186 216 12.00 AF 460-30-11
580 800 1 1 283 210 242 15.00 AF 580-30-11
750 1050 1 1 283 210 242 15.00 AF 750-30-11
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/10
A 145 ... AF 750 3-pole Contactors
Main accessories
Auxiliary Contact Blocks
Mounting on Positioning Contacts Weight Order Code
contactors kg
A 145 to Side 1 1 0.050 CAL 5-11
AF 750 1 1 0.050 CAL 5-11B
Electronic Timers for star-delta starters (dwelling time 50 ms) - (Prohibited with AF... contactors)
Mounting Timing rangeSupply voltage Weight Order Code
V kg
Independent Direct 24 a.c. / d.c. 0.080 TE5S-24
0.8 ... 8 s 110 ... 120 a.c. 0.080 TE5S-120
or 220 ... 240 a.c. 0.080 TE5S-240
6 ... 60 s 380 ... 440 a.c. 0.080 TE5S-440
Interlocks for two horizontal mounted contactors
Left Right Feature Weight Order Code
contactor contactor kg
A 95 ... 300 A 145 ... 300 Mechanical 0.150 VM 300H
A 210 ... 300 AF 400 ... 460 Mechanical 0.150 VM 300/460H
AF 400 ... 750 AF 400 ... 460 Mechanical 0.200 VM 750H
Surge Suppressors
Mounting on Feature Voltage range Weight Order Code
contactors kg
24 ... 50 V a.c. 0.015 RC 5-2/50
A 145 ... 300 RC 50 ... 133 V a.c. 0.015 RC 5-2/133
110 ... 250 V a.c. 0.015 RC 5-2/250
250 ... 440 V a.c. 0.015 RC 5-2/440
Note: The built-in coil interface eliminates the need of extra surge suppressors on the AF 400 to AF 750 contactors.
Shrouds (terminal protection acc. to VDE 0106, part 100) (pack of 2)
Mounting on Suitable for Weight Order Code
contactors contactor with kg
1 piece
A 145, A 185 Cable connectors 0.100 LT 185-AC
A 145, A 185 Cable lugs 0.100 LT 185-AL
A 210 ... A 300 Cable connectors 0.100 LT 300-AC
A 210 ... A 300 Cable lugs 0.100 LT 300-AL
AF 400, AF 460 Cable connectors 0.150 LT 460-AC
AF 400, AF 460 Cable lugs 0.800 LT 460-AL
AF 580, AF 750 Cable connectors 0.150 LT 750-AC
AF 580, AF 750 Cable lugs 0.850 LT 750-AL
Other Accessories
A wide range of accessories are available:
– LZ... connectors,
– LW... enlargement pieces for terminals,
– connecting auxiliaries: shorting bars, connection bars, additional pieces, etc.
– shrouds for shorting bars,
– interlocks for two vertical contactors,
– adapter plates.
LT…-AL
LT…-AC
TE5S-240
RC…
VM 300H
CAL 5-11
{
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
A 145 ... AF 750 3-pole Contactors
Thermal & Electronic O/L Relays
ABB LIMITED 2/11
E 800 DU
E 320 DU
TA 450 DU
TA 200 DU
A 185 contactor with
E 200 DU electronic O/L relay and
LT 200 E terminal shroud
Thermal O/L Relays, Class 10A
For Setting range Weight Order code
contactors: A kg
66 ... 90 0.750 TA 200 DU 90
80 ... 110 0.750 TA 200 DU 110
100 ... 135 0.750 TA 200 DU 135
A 145, A 185 110 ... 150 0.750 TA 200 DU 150
130 ... 175 0.750 TA 200 DU 175
150 ... 200 0.750 TA 200 DU 200
130 ... 185 1.500 TA 450 DU 185
A 210 ... A 300 165 ... 235 1.500 TA 450 DU 235
220 ... 310 1.500 TA 450 DU 310
AF400...AF750 Please consult us for thermal solution
Electronic O/L Relays, Adjustable Class 10, 20 and 30
For Setting range Weight Order code
contactors: A kg
A 145, A 185 60 ... 200 1.120 E 200 DU
A 210 ... A 300 100 ... 320 1.260 E 320 DU
AF 400, AF 460 150 ... 500 1.210 E 500 DU
AF 580, AF 750 250 ... 800 4.240 E 800 DU
Kit for Mounting on the Contactors
For For O/L relays: Weight Order code
contactors: kg
A 145, A 185 TA 450 DU/SU 0.500 DT 450/A 185
A 210 ... A 300 0.750 DT 450/A 300
AF 400, AF 460 E 500 DU 0.720 DT 500/AF 460 S
AF 580, AF 750 E 800 DU 1.400 DT 800/AF 750 S
Separate Mounting Kit
For O/L relay: Weight Order code
kg
TA 200 DU 0.230 DB 200
Terminal Shrouds for TA 200 DU Thermal O/L Relay
Fitting Weight Order code
kg
Load side 0.070 LT 200/A
Between TA 200 DU and A 145, A 185 0.050 LT 185-AY
Terminal Shrouds for Electronic O/L Relay
For electronic Weight Order code
O/L relay kg
E 200 DU 0.120 LT 200 E
E 320 DU 0.120 LT 320 E
E 500 DU 0.240 LT 500 E
E 800 DU 0.240 LT 800 E
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/12
AF 50 ... AF 750 3-pole Contactors
a.c. / d.c. Operated - Large Voltage Range
Electronic Coil Interface
Control circuit with
electronic coil interface.
Control inputs (AF
400 ... AF 750)
Application
AF 50 ... AF 750 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V a.c. or
220 V d.c. / 600 V d.c. The contactors can also be used for many other applications such as bypass, capacitor switching, lighting, d.c. power
circuits...
The AF... contactors are fitted with an electronic coil interface which accepts a wide control voltage range, on a.c. 50/60 Hz or d.c. supplies.
The same contactor can accept various supply voltages according to different countries where the final machine will be used or some
fluctuation in the control voltage due to the local supply or network.
The AF... contactors are also fully suitable for operation in a.c. or d.c. control circuit liable to voltage interruptions or voltage dip risks.
Description
The AF 50 ... AF 750 3-pole contactors are of the block type design.
• Main poles and auxiliary contact blocks
3 main poles,
-AF50 ... AF110 front and side mounted add on auxiliary contact blocks
AF145 ... AF750 1 N.O. and 1 N.C. auxiliary contact block (fitted on the left side).
A maximum of 4 auxiliary contact blocks can be fitted on each contactor.
Electronic control:
The contactors are fitted with an electronic interface that very precisely controls the voltage to the coil. The electronic control circuit always
works using d.c. current through the coil and in a.c. operation the current is rectified before being applied to the coil. To achieve the levels of
the currents required for making and holding respectively, the voltage is pulsed across the coil with the aid of a transistor. The pulsing also
implies that the current in the coil can be optimally regulated all the time relatively independently of the voltage level. The function is controlled
by a specific integrated circuit developed by ABB.
• Advantages
Wide voltage range, e.g. 100 ... 250 V a.c. and d.c.,
Can manage large voltage variations,
Reduced power consumption,
Very distinct closing and opening,
Noise free,
Can withstand voltage interruptions or voltage dips in the control supply (< 20 ms).
• Control inputs
The large sizes AF 400 ... AF 750 are as standard equipped with low voltage inputs for control, for example by a PLC (+ see drawing below).
Accessories: a wide range of accessories is available.
Operating diagram
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/13
AF 50 ... AF 750 3-pole Contactors
a.c. / d.c. Operated - Large Voltage Range
Electronic Coil Interface
Rated operational Auxiliary contacts Footprint Weight Order Code
current fitted H W D kg
AC-3 AC-1
400 V θ 40 °C state coil voltage
A A
50 100 1 1 110 82 108 1.220 AF 50-30-11
65 115 1 1 110 82 108 1.220 AF 63-30-11
75 125 1 1 110 82 108 1.220 AF 75-30-11
96 145 1 1 148 102 124 2.070 AF 95-30-11
110 160 1 1 148 102 124 2.070 AF 110-30-11
145 250 1 1 196 112 160 3.600 AF 145-30-11
185 275 1 1 196 112 160 3.600 AF 185-30-11
210 350 1 1 227 140 181 6.200 AF 210-30-11
260 400 1 1 227 140 181 6.200 AF 260-30-11
305 500 1 1 227 140 181 6.200 AF 300-30-11
400 600 1 1 278 186 216 12.00 AF 400-30-11
460 700 1 1 278 186 216 12.00 AF 460-30-11
580 800 1 1 283 210 242 15.00 AF 580-30-11
750 1050 1 1 283 210 242 15.00 AF 750-30-11
AF 750-30-11
AF 460-30-11
AF 95-30-11
AF 50-30-11
Coil voltages: AF 50 ... AF 300
Voltage Voltage
V - 50/60Hz V d.c.
20 ... 60
48 ... 130 48 ... 130
100 ... 250 100 ... 250
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
Coil voltages: AF 400 ... AF 750
Voltage Voltage
V - 50Hz V d.c
24 ... 60
48 ... 130 48 ... 130
100 ... 250 100 ... 250
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
Electromagnetic compatibility:
AF... contactors comply with international standards IEC 60947-1 (2000-10-Ed.3.1), 60947-4-1 (2000-11-
Ed.2) and European standards EN 60947-1, 60947-4-1.
Notice: This product has been designed for environment A. Use of this product in environment B may
cause unwanted electromagnetic disturbances in which case the user may be required to take adequate
mitigation measures.
Definitions:
Environment A: "Mainly relates to low-voltage non public or industrial networks/locations/installations
(+EN 50082-2 article 4) including highly disturbing sources".
Environment B: "Mainly relates to low-voltage public networks (+EN 50082-1 article 5) such as
residential, commercial and light industrial locations/installations. Highly disturbing sources such as arc
welders are not covered by this environment".
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Application
AE9 ... AE 40 contactors are mainly used for controlling 3-phase motors and generally for controlling
power circuits up to 690 V a.c. or 220 V d.c. / 440 V d.c.
Description
The AE... series 3-pole contactors are d.c. operated contactors.
• Main poles and auxiliary contact blocks
- 3 main poles,
- front and side mounted add-on auxiliary contact blocks.
auxiliary contacts for safety circuits page x/xx
• Control circuit: laminated magnet circuit and double-winding coil fed from d.c. supply via an insertion
contact mounted on the device
- AE9 ... AE40: built-in lagging contact for insertion of the second winding
• Accessories: a wide range of accessories are available
Rated operational Auxiliary contacts Footprint
current fitted H W D Order Code
AC-3 AC-1
400 V θ 40 °C state coil voltage
A A
9 25 - - 74 44 74 AE 9-30-00
12 27 - - 74 44 74 AE 12-30-00
16 30 - - 74 44 74 AE 16-30-00
26 45 - - 90 54 94 AE 26-30-00
32 55 - - 90 54 108 AE 30-30-00
37 60 - - 90 54 108 AE 40-30-00
For d.c. operation with solid magnetic circuit please consult us.
For accessories see main accessories A9 - A110 page x/xx
ABB LIMITED 2/14
AE 3-pole Contactors
d.c. Operated with Double - Winding coil
Coil voltages:
AE...
Voltage - Uc
V d.c.
12
24
42
48
50
60
75
110
125
220
240
250
*RV 5 surge suppressor fitted as
standard (RT 5 type on request).
*Addition of RT 5 or RV 5 surge suppressor, if required.
Please order separately
AE... contactors specific design
• AE 9 ... AE 40: Built-in lagging contact for insertion of the "holding" winding
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/15
Connection Sets
Connections for Reversing Contactors
Application
Connections between the main poles of two 3-pole contactors mounted side by side so that they operate
as reversing contactors.
Description
The sets are made up of three upstream connections and three downstream connections.
BEM 16-30 – Insulated, solid, rigid copper wires
BEM 26-30, BEM 40-30 – Insulated, stranded, rigid copper wires
BEM 75-30 ... BEM 750-30 – Insulated, solid copper bars
BSM 16-30, BSM 25-30 BC and BSM 30-30 BC – Insulated, solid, rigid copper wires
On the A... contactors, the power supply by bars or cables equipped with lugs is directly connected to the
terminal pads of the main poles. For flange connectors (+ page ????), LX… terminal extension pieces
should be used (+ page ????).
Mounting on 3-pole Weight Order code
contactors kg
1 set
A 9 ... A 16 0.025 BEM 16-30
A 26 0.056 BEM 26-30
A 30, A 40 0.096 BEM 40-30
A 50 ... A 75 0.243 BEM 75-30
A 95, A 110 0.450 BEM 110-30
A145, A 185 0.900 BEM 185-30
A 210 ... A 300 1.100 BEM 300-30
AF 400, AF 460 4.400 BEM 460-30
AF 580, AF 750 7.300 BEM 750-30
BC 9, BC 16 0.015 BSM 16-30
BC 25 0.020 BSM 25-30 BC
BC 30 0.025 BSM 30-30 BC
Note:The connections provided for the A... contactors can be used for the AF, AE and TAE types.
The connections provided for the BC... contactors can be used for the TBC types.
3-pole Connections Phase to Phase
Application
Connections between the main poles of two 3-pole contactors horizontal mounted.
Description
This set is made up of three downstream or upstream connections.
Mounting on 3-pole Weight Order code
contactors kg
1 set
A 50 ... A 75 0.130 BES 75-30
A 95, A 110 0.250 BES 110
A 145, A 185 0.500 BES 185
A 210 ... A 300 1.000 BES 300
AF 400, AF 460 2.200 BES 460
AF 580, AF 750 3.700 BES 750
Note: The connections provided for the A... contactors can be used for the AF, AE and TAE types.
BEM… connections
BES... for 3-pole connections
BES…
BEM 75-30
BEM 300-30
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/16
Connections for Star-Delta Starters
Application
Connections between the main poles of a star-delta starter.
Description
These sets are made up of:
– Three line contactor / delta contactor connections - Upstream side.
– Three connections for star and delta contactors mounting joined side by side - Downstream side.
– The necessary elements to create the star point upstream of the star contactor.
BED 16, BED 26 – Insulated, solid copper wires.
BED 40 – Insulated, stranded solid copper wires.
BED 50, BED 75 – Solid copper bars and insulated stranded copper wires.
BED 95 ... BED 750 – Insulated, solid copper bars.
BED kits are designed to accomodate mechanical interlock
For contactors Weight Order code
Line and Delta Star kg
A 9 A 9
A 12 A 9 0.040 BED 16
A 16 A 12
A 26 A 16 0.045 BED 26
A 30 A 26 0.070 BED 40
A 40 A 26
A 50 A 30 0.180 BED 50
A 63 A 40
A 75 A 50 0.180 BED 75
A 95 A 75 0.400 BED 95
A 110 A 95 0.500 BED 110
A 145 A 110 1.300 BED 145 A
A 185 A 145 1.100 BED 185
A 210 A 185 1.500 BED 210
A 260, A 300 A 210, A 260 2.100 BED 300
AF 400 / AF 460 A 260 / A 300 3.500 BED 400
AF 460 AF 400 4.700 BED 460
AF 580 AF 460 / AF 400 6.300 BED 580
AF 750 AF 580 7.700 BED 750
Note: The connections provided for A... contactors can be used for the AF, AE, and TAE types.
BED... Connection Sets
BED 400
BED 185
BED 110
BED 75-1
BED 40
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/17
Star-Delta Starting
of Three-Phase Asynchronous Motors
Controlgear Selection Guide
Ambient temperature = 55 °C.
Please consult us for type 1&2 coordinates combinations
Motor power, kW Max. starting Contactors O/L Relay Timer Set of power
time from (1) connections
cold (3)
220- 240 V 380- 415 V 500 V 660- KM1 KM3 KM2
230 V 400 V 690 V seconds Main Delta Star
4 4 7.5 7.5 5.5 5.5 15 A 9 A 9 A 9 TA 25 DU TE5S BED 16 (4)
5.5 5.5 11 11 7.5 7.5 15 A 12 A 12 A 9 TA 25 DU TE5S BED 16 (4)
9 11 15 15 15 11 15 A 16 A 16 A 12 TA 25 DU TE5S BED 16 (4)
12.5 12.5 22 22 22 15 15 A 26 A 26 A 16 TA 25 DU TE5S BED 26 (4)
15 15 25 25 25 18.5 15 A 30 A 30 A 26 TA 25 DU TE5S BED 40 (4)
18.5 22 37 37 37 37 30 A 40 A 40 A 26 TA 42 DU TE5S BED 40 (4)
25 25 45 45 45 45 30 A 50 A 50 A 30 TA 75 DU TE5S BED 50 (4)
30 33 55 55 63 59 30 A 63 A 63 A 40 TA 75 DU TE5S BED 50 (4)
37 40 63 70 75 63 30 A 75 A 75 A 50 TA 75 DU TE5S BED 75 (4)
45 45 75 75 90 90 20 A 95 A 95 A 75 TA 110 DU TE5S BED 95 (5)
55 59 90 100 110 132 20 A 110 A 110 A 95 TA 110 DU TE5S BED 110 (5)
75 75 132 132 160 160 20 A 145 A 145 A 110 TA 200 DU TE5S BED 145 (5)
90 90 160 160 200 250 20 A 185 A 185 A 145 TA 200 DU TE5S BED 185 (5)
110 110 200 200 250 315 20 A 210 A 210 A 185 TA 450 DU TE5S BED 210 (5)
140 140 220 250 295 355 20 A 260 A 260 A 210 TA 450 DU TE5S BED 300 (5)
160 160 250 250 355 450 20 A 300 A 300 A 260 TA 450 DU TE5S BED 300 (5)
180 200 355 355 450 560 20 AF 400 AF 400 A 260 E 500 DU (2) BED 400 (5)
250 250 450 475 560 670 20 AF 460 AF 460 A 300 E 500 DU (2) BED 400 (5)
315 315 560 600 700 750 20 AF 580 AF 580 AF 400 E 800 DU (2) BED 580 (5)
400 400 670 670 750 900 20 AF 750 AF 750 AF 460 E 800 DU (2) BED 580 (5)
(1) The setting current value is: nominal motor current x 0.58. (4) Version without space for mechanical interlock.
(2) Contactor Relay type N + TP timer can be used as the AF contactors have a slight delay in closing. (5) Version with space for mechanical interlock.
(3) Usual time value = 6 ... 10 s.
Power circuit diagram Control circuit diagrams - Remote control
A 9 ... AF 750 Contactors A 9 ... A 300 Contactors AF 400 ... AF 750 Contactors
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/18
Star-Delta Starting
of Three-Phase Asynchronous Motors
General
When starting, the motor has to overcome the load torque and inertia of the driven machine. During this phase, current must
remain within the limits acceptable by the mains.
Inertia, load torque and mains are commonly fixed data.
Although the type of starting reduces the inrush current as required, it also reduces the torque supplied by the motor. The result is a starting
time that varies according to the starting process used.
Star-delta starting
Technical Data
When starting:
– inrush current is reduced to a third of direct starting current,
– motor torque is reduced to a third or even less of direct starting
torque.
Transient currents are commonly read during star-delta switching.
Utilization
During the initial starting phase ("star" connection), the resistive torque
of the driven machine must remain, irrespective of speed, less than the
"star" motor torque until "star-delta" switching occurs.
This starting mode is therefore ideal for machines with no-load starting:
– machine-tools,
– centrifugal compressors,
– wood working machines, etc.
In order to prevent a high current peak, at least 80 - 85 % of
nominal speed must be reached before switching from star to
delta.
Precautions
Motor nominal voltage in delta connection must be equal to that of the
mains.
Example:
A motor for 400 V star-delta starting must be designed for 400 V in
"delta" connection. Its usual designation is "400 V / 690 V motor". The
motor must be constructed with 6 terminal windings.
Sequence
Starting is a three-stage process:
1st stage - "Star" connection
Press the "On" button on the control circuit to close the KM2 "star" contactor. The KM1 "line" contactor then closes and the motor starts.
Countdown of programmed starting time (normally 6 to 10 s) then begins.
2nd stage - "Star" to "Delta" switching
When the programmed starting time is over, the KM2 "star" contactor opens.
3rd stage - "Delta" connection
A transition time (or dwelling time) of 50 ms is fixed between opening of the "star" contactor and closing of the "delta" contactor by the use of
TE5S timer. This prevents short circuit between "star" and "delta".
Note: When AF... contactor types are used as delta and star contactors or an A... contactor as star contactor with an AF... contactor as delta contactor, the use of a timer including a
dwelling time (or transition time) e.g. TE5S or similar is not necessary. A timer set for the starting duration in star connection is enough. An electrical interlock between star and delta is
mandatory such as VE 5 or through auxiliary contacts.
Furthermore, in open transition, the current interruption may reach up to 95 ms: it shall be checked that this duration is compatible with the application i.e. mainly if the decreasing in rotation
speed is acceptable during the starting phase.
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/19
Connection Bars for Contactor and MCCB
Connection Bars for Contactor and Switch fuse
Application
Connections between contactors/starters and moulded case circuit breakers or switch fuses.
Description
These connection sets are solid copper bars either isolated or protected by shrouds.
Connection bars between contactor and MCCB
Vertical assembly
Contactors MCCB Weight Order code
kg
A 145, A 185 T 3 0.150 BEA 185/T3
A 145, A 185 S 3, S 4 0.150 BEA 185/S3/S4
A 210 S 4 0.160 BEA 210/S4
A 210 ... A 300 S 5 0.200 BEA 300/S5
AF 400, AF 460 S 5 0.250 BEA 400/S5
AF 400 ... AF 750 S 6 0.410 BEA 750/S6
Vertical assembly with control wire terminals (Also suitable when using busbar kits for starter combinations)
A 145, A 185 T 3 0.175 BEA 185 D/T3
A 145 ... A 185 S 3, S 4 0.200 BEA 185D/S3/S4
A 210 S 4 0.270 BEA 210D/S4
A 210 ... A 300 S 5 0.320 BEA 300D/S5
AF 400, AF 460 S 5 0.480 BEA 400D/S5
AF 400 ... AF 750 S 6 0.720 BEA 750D/S6
Horizontal assembly (Also suitable when using busbar kits for starter combinations)
A 145, A 185 S 3, S 4 0.520 BEA 185H/S4
A 210 S 4 0.620 BEA 210H/S4
A 210, A 300 S 5 1.280 BEA 300H/S5
AF 400, AF 460 S 5 1.310 BEA 400H/S5
AF 400, AF 460 S 6 2.450 BEA 460H/S6
AF 580, AF 750 S 6 4.010 BEA 750H/S6
Note: The BEA... connection bars provided for the A 145 ... A 300 contactors can be used for the AF 145 ... AF 300 contactors.
Connection bars between contactor and switch fuse
Vertical assembly
Contactors Switch fuse Weight Order code
kg
1 piece
A 185 OESA 250 0.260
A210 ... A 300 OESA 250 to 0.330 BEF 185/OESA250
OESA 400 BEF 300/OESA400
AF 400 ... AF 460 OESA 400 0.340
AF 460 ... AF 750 OESA 630 to 0.740 BEF 460/OESA400
OESA 800 BEF 750/OESA800
Horizontal assembly
A 145 OS 160..LR 0.170 OSZA 15
A 145, A 185 OESA 250..LR 0.550 BEF 185H/OESA250
A 210 ... A 300 OESA 250..LR to BEF 300H/OESA400
OESA 400..LR
AF 400, AF 460 OESA 400..LR 1.250 BEF 460H/OESA400
Note: The BEF... connection bars provided for the A 145 ... A 300 contactors can be used for the AF 145 ... AF 300 contactors.
A 300-30 contactor + MCCB on top
BEA...D/S
BEF 300/OESA400
BEA 300H/S5
BEA 300/S5
BEF 300H/OESA400
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/20
RV 5
RC 5-1
VE 5-1
VM 5-1
TP 40 DA, TP 180 DA
Direct timing - Front m
TE5S Direct timing - Indep
Auxiliary CA 5-..,1-pole Types
contacts CAL ..-..,2-pole
Timers TP..,Pneumatic Types
TE..,Electronic
Supply voltages: 24 V a.c./d.c.,
110 ... 120; 220 ... 240; 380 ... 440 V a.c.
Interlocks VE 5-.,Mechanical/Electrical Types
VM..., VH... Mechanical
mounting between 2 contactors
Surge RV..,(Varistor) a.c./d.c. Types
suppressors RC..,(Capacitor) a.c.
CA 5-10 1-pole, front mounting CA 5-01 1-pole, front mo
Selection & Ordering
Select accessory type and
quote required data in plain
text.
Selection & Ordering
Select 4 N.O. or 2 N.O. + 2 N.C. main poles
Select contactor type.
Select contactor coil voltage on cover folding
page 0/1, according to control circuit supply.
(Please quote coil voltage in plain text).
AC-1 utilization category
When m a k i n g,
the switched-on
current is equal
to the Inl o a d
rated current with
cos ϕ 0.95.
1 x N.C.1 x N.O.
A 9 A 16 A 26
Switching of Resistive Circuits
Rated < 40 °C A25 30 45
AC-1 operational < 55 °C A22 27 40
current < 70 °C A18 23 32
With conductor cross-sectional area mm22.5 4 6
Rated operational voltage V690
4 N.O. main poles
A 9-40-00 A 26-40-00
a.c. Control circuit supply Types A 16-40-00
d.c. Control circuit supply Types
2 N.O. + 2 N.C. main poles
A 9-22-00
a.c. Control circuit supply Types A 16-22-00 A 26-22-00
a.c. Circuit Switching
4-pole contactors
Contactor Main
Accessories
A.., AF.., 4-pole Contactors
Return to main indexReturn to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/21
RC-EH 800
(Varistor + RC)
RC-EH 300
RV 5
RC 5-2
VH 800
VH 300
(Mechanical / Electrical)
VH 145
(Mechanical / Electrical)
VE 5-2
TE5S Direct timing - Independent mounting (interpose an N.. contactor relay for EK 370 ... EK 1000)
CAL 16-11 2-pole, side mounting
1 x N.O. + 1 x
N.C.
1 x N.O. + 1 x
N.C.
0 IA, TP 180 IA Inverse timing - Front mounting
ng
CAL 5-11 2-pole, side mounting
A 45 A 50 A 75 EK110 EK150 EK175 EK210 EK370 EK550 EK1000
70 100 125 200 250 300 350 550 800 1000
60 85 105 180 230 270 310 470 650 800
50 70 85 155 200 215 250 400 575 720
25 35 50 95 150 185 240 2 x 185 2 x 240 2 x 300
690 1000 690
A 45-40-00 EK110-40-11 EK175-40-11 EK370-40-11
A 50-40-00 EK550-40-11
A 75-40-00 EK150-40-11 EK210-40-11 EK1000
-40-11
AF45-40-00 EK110-40- 21 EK 175-40-21 EK370-40-21
AF50-40-00 EK 550-40-21
AF75-40-00 EK150-40-21 EK210-40-21 EK1000-40-21
A 45-22-00
A 75-22-00
Return to main index
ABB LIMITED 2/22
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
A 9 ... A 75 4-pole Contactors
a.c. Operated
Rated operational Auxiliary contacts Footprint Weight Order code
current fitted kg
AC-1
40 °C H W D state coil voltage
A
4 N.O. main poles
25 74 44 74 0.340 A 9-40-00
30 74 44 74 0.340 A 16-40-00
45 90 54 94 0.610 A 26-40-00
70 110 92 120 1.390 A 45-40-00
100 110 92 120 1.390 A 50-40-00
125 110 92 120 1.390 A 75-40-00
2 N.O. + 2 N.C. main poles
25 74 44 74 0.340 A 9-22-00
30 74 44 74 0.340 A 16-22-00
45 90 54 94 0.610 A 26-22-00
70 110 92 120 1.400 A 45-22-00
125 110 92 120 1.400 A 75-22-00
A 9-22-00
A 45-40-00
A 9-40-00
Coil voltages
Voltage Voltage
V - 50Hz V - 60Hz
24 24
48 48
110 110 ... 120
220 ... 230 230 ... 240
230 ... 240 240 ... 260
380 ... 400 400 ... 415
400 ... 415 415 ... 440
Other voltages on application
Remark for A 9 ... A 75 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or
1 circuit comprising 2 separate loads with a single supply (see diagrams below). When the contactor
operates there is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before
MAKE.
These contactors are not suitable for a reversing starter or star-delta starter or for controlling a
single load from 2 separate supplies.
Block diagrams
Single supply and 2 separate loads 2 separate supplies and 2 separate loads
BES... for 4-pole connections
Connections for 4-pole Changeover Contactors
Application
Connection between the main poles of two 4-pole contactors mounted side by side so that they operate
as source reversing contactors.
Description
These sets are made up of four downstream connections, with insulated, stranded, rigid copper cables.
Mounting on 4-pole Weight Order code
contactors kg
1 set
A 45, A 50, A 75 1 0.400 BES 75-40
Note: The connections provided for the A... contactors can be used for the AF, AE and TAE types.
Return to main index
A 9 ... A 75 4-pole Contactors
Main Accessories
CA 5-10 CAL 5-11
TP 40 DA
VE 5-1
RC 5-1/50RV 5/50
Auxiliary Contact Blocks
Mounting on Positioning Contacts Weight Order code
contactors kg
A 9 ... A 75 Front face 1 0.014 CA 5-10
1 0.014 CA 5-01
4 0.060 CA 5-40 E
2 2 0.060 CA 5-22 E
A 9 ... A 75 Side 1 1 0.050 CAL 5-11
Pneumatic Timers
Mounting on Timing range Contacts Weight Order code
contactors kg
Direct 0.1 ... 40 s 1 1 0.070 TP 40 DA
A 9 ... A 75 Direct 10 ... 180 s 1 1 0.070 TP 180 DA
Inverse 0.1 ... 40 s 1 1 0.070 TP 40 IA
Inverse 10 ... 180 s 1 1 0.070 TP 180 IA
Interlocks
Mounting on Feature Contacts Weight Order code
contactors kg
A 9 ... A 26 Mech. / electrical 2 0.076 VE 5-1
A 45 ... A 75 2 0.146 VE 5-2
A 9 ... A 26 Mechanical 0.066 VM 5-1
Surge Suppressors
Mounting on Feature Voltage range Weight Order code
contactors kg
24 ... 50 V a.c./d.c. 0.015 RV 5/50
A 9 ... A 75 Varistor 50 ... 133 V a.c./d.c. 0.015 RV 5/133
110 ... 250 V a.c./d.c. 0.015 RV 5/250
250 ... 440 V a.c./d.c. 0.015 RV 5/440
24 ... 50 V a.c. 0.012 RC 5-1/50
A 9 ... A 26 RC 50 ... 133 V a.c. 0.012 RC 5-1/133
110 ... 250 V a.c. 0.012 RC 5-1/250
250 ... 440 V a.c. 0.012 RC 5-1/440
24 ... 50 V a.c. 0.015 RC 5-2/50
A 45 ... A 75 RC 50 ... 133 V a.c. 0.015 RC 5-2/133
110 ... 250 V a.c. 0.015 RC 5-2/250
250 ... 440 V a.c. 0.015 RC 5-2/440
Other Accessories
A wide range of accessories are available.
– various auxiliary contact blocks for specific controls and use,
– interface relays,
– connecting auxiliaries: strips, connectors, additional pieces, etc.
– impulse contact blocks, lamp holder and fuse holder blocks,
– function marker.
ABB LIMITED 2/23
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/24
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
EK 110 ... EK 1000 4-pole Contactors
a.c. Operated
Rated operationa Auxiliary contacts Footprint Weight Order code
current fitted kg
AC-1
q 40 °C H W D state coil voltage
A
200 1 1 156 165 155 4.300 EK 110-40-11
250 1 1 172 165 155 4.350 EK 150-40-11
300 1 1 198 201 172 6.600 EK 175-40-11
350 1 1 198 201 172 6.600 EK 210-40-11
550 1 1 272 270 226 17.20 EK 370-40-11
800 1 1 272 270 226 17.20 EK 550-40-11
1000 1 1 299 270 226 17.50 EK 1000-40-11
- E = 40 ... 400 Hz coil with built-in rectifier.
Coil voltages and codes: EK 110 ... EK 1000
Voltage Voltage Code
V - 50Hz V - 60Hz
48 A D
110 A E
110 120 A F
220 ... 230 * A L *Read 240V 60Hz for
230 ... 240 A M EK 370 ... EK 1000.
380 A N
380 ... 400 440 A P
400 ... 415 A R
+ Other voltages: page 0/1.
Multi-frequency coils: EK 110 ... EK 210
Voltage Code
V - 40 ... 400Hz
110 ... 120 E F
115 ... 127 E G
220 ... 230 E L
230 ... 240 E M
380 ... 400 E P
400 ... 415 E R
Dual frequency coils (1): EK 370 ... EK 1000
Voltage Voltage Code
V - 50Hz V - 60Hz
110 110 ... 120 E F
110 ... 115 115 ... 127 E G
220 220 ... 240 E L
220 ... 230 230 ... 255 E M
380 380 ... 415 E P
380 ... 400 400 ... 440 E R
(1) Two auxiliary contact blocks maximum per contactor, ambient temperature < 55 °C and mounting
positions 2 and 6 excluded.
EK 1000-40-11
EK 370-40-11
EK 175-40-11
Return to main index
EK 110 ... EK 1000 4-pole Contactors
Main Accessories
Auxiliary Contact Blocks
Mounting on Positioning Contacts Weight Order code
contactors kg
EK 110 ... EK 1000 Side 1 1 0.050 CAL 16-11 B
1 1 0.050 CAL 16-11 C
1 1 0.050 CAL 16-11 D
Interlocks for two horizontal mounted contactors
Mounting on Feature Contacts Weight Order code
contactors kg
EK 110, EK 150 Mech. / elec. 2 0.130 VH 145
EK 175, EK 210 2 0.130 VH 300
EK 370, EK 550 Mechanical 6.000 VH 800
EK 1000
Note: For interlocking between two contactors of a different size: + section 4.
Surge Suppressors
Mounting on Feature Voltage range Weight Order code
contactors kg
EK 110 ... EK 210 RC 24 ... 48 V a.c. 0.015 RC-EH 300/48
110 ... 415 V a.c. 0.015 RC-EH 300/415
EK 370 ... EK 1000 RC 48 ... 110 V a.c. 0.015 RC-EH 800/110
220 ... 600 V a.c. 0.015 RC-EH 800/600
Shrouds (terminal protection VDE 106, part 100)
Mounting on Suitable for Weight Order code
contactors contactor with kg
EK 110, EK 150 cable lugs 0.139 LT 150-EK
EK 175, EK 210 or 0.152 LT 210-EK
EK 370, EK 550 cable clamps 0.190 LT 550-EK
EK 1000 0.200 LT 1000-EK
Other Accessories
A wide range of accessories are available:
– auxiliary contact blocks for specific controls and use,
– connecting auxiliaries: connectors for main poles, connections sets,
– plates for changeover contactors, etc.
LT 210-EK
RC-EH 300/48
VH 145
CAL 16-11 B
ABB LIMITED 2/25
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
ABB LIMITED 2/26
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
AF 45 ... AF 75 4-pole Contactors
a.c. / d.c. Operated - Large Voltage Range
Electronic Coil Interface
Rated operational Auxiliary contacts Footprint Weight Order code
current fitted kg
AC-1
40 °C H W D state coil voltage
A
4 N.O. main poles
70 110 92 120 1.420 AF 45-40-00
100 110 92 120 1.420 AF 50-40-00
125 110 92 120 1.420 AF 75-40-00
2 N.O. + 2 N.C. main poles
70 110 92 120 1.420 AF 45-22-00
125 110 92 120 1.420 AF 75-22-00
AF 75-40-00
Coil voltages
Voltage Voltage
V - 50/60Hz V d.c.
20 ... 60
48 ... 130 48 ... 130
100 ... 250 100 ... 250
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
Remark for AF 45 ... AF 75 4-pole contactors built with 2 N.O. + 2 N.C. main poles
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1
circuit comprising 2 separate loads with a single supply (+ diagrams below). When the contactor operates
there is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before MAKE.
These contactors are not suitable for a reversing starter or star-delta starter or for controlling a
single load from 2 separate supplies.
Block Diagrams
Single supply and 2 separate loads 2 separate supplies and 2 separate loads
Electromagnetic compatibility:
AF... contactors comply with international standards IEC 60947-1 (2000-10-Ed.3.1), 60947-4-1 (2000-11-
Ed.2) and European standards EN 60947-1, 60947-4-1.
Notice: This product has been designed for environment A. Use of this product in environment B may
cause unwanted electromagnetic disturbances in which case the user may be required to take adequate
mitigation measures.
Definitions:
Environment A: "Mainly relates to low-voltage non public or industrial networks/locations/installations
(+ EN 50082-2 article 4) including highly disturbing sources".
Environment B: "Mainly relates to low-voltage public networks (+ EN 50082-1 article 5) such as residential,
commercial and light industrial locations/installations. Highly disturbing sources such as arc welders are not
covered by this environment".
Return to main index
EK 110 ... EK 1000 4-pole Contactors
d.c. Operated
EK 1000-40
EK 370-40
EK 175-40
Rated operational Auxiliary contacts Footprint Weight Order code
current fitted kg
AC-1
40 °C H W D state coil voltage
A
200 2 1 156 136 155 4.350 EK 110-40-21
250 2 1 172 136 155 4.400 EK 150-40-21
300 2 1 198 176 172 6.650 EK 175-40-21
350 2 1 198 176 172 6.650 EK 210-40-21
550 2 1 272 296 226 17.20 EK 370-40-21
800 2 1 272 296 226 17.20 EK 550-40-21
1000 2 1 299 296 226 17.50 EK 1000-40-21
Coil voltages and codes
Voltage Code
V d.c.
12 (1) D A
24 D B
36 D C
48 D D
60 D T
75 D G
110 D E
125 D U
220 D F
(1) Not for EK 370 ... EK 1000 contactors.
For Accessories see page ??
ABB LIMITED 2/27
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/28
Contactors for Capacitor Switching
AC-6b Utilization Category according to IEC 60947-4-1
Capacitor Transient Conditions
In Low Voltage industrial installations, capacitors are mainly used for reactive energy correction (raising the power factor). When these
capacitors are energized, overcurrents of high amplitude and high frequencies (3 to 15 kHz) occur during the transient period (1 to 2 ms).
The amplitude of these current peaks, also known as "inrush current peaks", depends on the following factors:
The network inductances.
The transformer power and short-circuit voltage.
The type of power factor correction.
There are 2 types of power factor correction: fixed or automatic.
Fixed power factor correction consists of inserting, in parallel on
the network, a capacitor bank whose total power is provided by
the assembly of capacitors of identical or different ratings.
The bank is energized by a contactor that simultaneously
supplies all the capacitors (a single step).
The inrush current peak, in the case of fixed correction, can
reach 30 times the nominal current of the capacitor bank.
Fixed power factor correction
An automatic power factor correction system, on the other hand,
consists of several capacitor banks of identical or different ratings
(several steps), energized separately according to the value of the
power factor to be corrected.
An electronic device automatically determines the power of the
steps to be energized and activates the relevant contactors.
The inrush current peak, in the case of automatic correction,
depends on the power of the steps already on duty, and can
reach 100 times the nominal current of the step to be energized.
Automatic power factor correction
Steady State Condition Data
The presence of harmonics and the network's voltage tolerance lead to a current, estimated to be 1.3 times the nominal current Inof the
capacitor, permanently circulating in the circuit.
Taking into account the manufacturing tolerances, the exact power of a capacitor can reach 1.15 times its nominal power.
Standard IEC 831-1 Edition 04/97 specifies that the capacitor must therefore have a maximum thermal current ITof:
IT= 1.3 x 1.15 x In= 1.5 x In
Consequences for the Contactors
To avoid malfunctions (welding of main poles, abnormal temperature rise, etc.), contactors for capacitor bank switching must be sized to
withstand:
A permanent current that can reach 1.5 times the nominal current of the capacitor bank.
The short but high peak current on pole closing (maximum permissible peak current Î ).
ABB offers 3 contactor versions according to the value of the inrush current peak and the
power of the capacitor bank
A... and AF... standard contactors (A 12... A 300 and AF 400 ... AF 750)
UA... Contactors for capacitor switching (UA 16 ... UA 110)
UA...-R Contactors for capacitor switching (UA 16-R ... UA 75-R) with insertion of damping resistors
Return to main indexReturn to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/29
A... Standard 3-pole Contactors
for Capacitor Switching
Peak Current Î< 30 Times the rms Current
Application
The A... and AF... contactors are suited for capacitor bank switching for the peak current and power values in the table below.
The kvar ratings acc. to the table below are applicable to "star" connected capacitors (less current, cable savings).
The capacitors must be discharged (maximum residual voltage at terminals < 50 V) before being re-energized when the contactors are making.
In these conditions, electrical durability of contactors is equal to 100 000 operating cycles.
Description
A 12 ... A 110 3-pole contactors
A 145 ... AF 750 3-pole contactors
Selection Table
Type Powers in kvar 50/60 Hz (AC - 6b) Max.
peak
220/240 V 380/400 V 415/440 V 500/550V 660/690 V current
40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C Î (kA)
A 9
A 12 7 7 6 11 11 9.5 12 12 10.5 14 14 12 19 19 16.5 0.7
A 16 7.5 7.5 6 12.5 12.5 10 14 14 10.5 15.5 15.5 12 21.5 21.5 16.5 1
A 26 11.5 11.5 9 19 19 15 20 20 16.5 23 23 19 32 32 26 1.6
A 30 13 13 11 22 22 18.5 24 24 20.5 28 28 23 38 38 32 1.9
A 40 15 15 12 26 26 20 29 29 22 35 35 25 46 46 34.5 2.1
A 50 22 22 20 38 38 34 42 42 37 48 48 42 65 65 58.5 2.3
A 63 25 25 23 43 43 39 47 47 42.5 54 54 48.5 74 74 67 2.5
A 75 28 28 24.5 48 48 41 52 52 45 60 60 51 82 82 70 2.6
A 95 35 35 33 60 60 53 63 63 58 75 75 70 80 80 75 4
A 110 40 40 35 70 70 60 75 75 65 83 83 78 90 90 85 4
A 145 50 50 42 90 90 74 93 93 80 110 110 96 110 110 110 4
A 185 60 60 45 105 105 78 115 115 85 135 135 102 135 135 135 5
A 210 75 75 57 125 125 100 135 135 110 160 160 130 160 160 160 6.5
A 260 85 85 70 140 140 130 155 155 140 180 180 165 200 200 200 8
A 300 100 100 85 160 160 150 180 180 163 210 210 196 240 240 240 8
AF 400 120 120 105 200 200 185 220 220 200 260 260 241 300 300 300 10
AF 460 140 140 120 230 230 215 260 260 230 325 325 300 325 325 325 10
AF 580 170 170 160 270 270 260 300 300 290 350 350 340 440 440 440 12
AF 750 220 220 190 390 370 332 410 410 380 490 480 435 600 600 600 12
If, in an application, the current peak is greater than the maximum peak current Îspecified in the last column in the table, select a higher rating,
refer to the UA... contactors (+page 2/38) or add inductances (+Application Guide "Contactors for Capacitor Switching").
The capacitor bank will be protected by gG type fuses whose rating is equal to 1.5 ... 1.8 times nominal current.
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/30
UA... 3-pole Contactors
for Capacitor Switching
Peak Current Î < 100 Times the rms Current
Application
The UA.. contactors have been specially developed for the switching of capacitor banks whose inrush current peaks are less than or equal to
100 times nominal rms current. The table below gives the permissible powers according to operational voltage and temperature close to the
contactor. It also specifies the maximum peak current Î values accepted by the contactor.
The kvar ratings acc. to the table below are applicable to "star" connected capacitors (less current, cable savings).
The capacitors must be discharged (maximum residual voltage at terminals < 50 V) before being re-energized when the contactors are making.
In these conditions, electrical durability of contactors is equal to 100 000 operating cycles.
Selection Table
Type Powers in kvar 50/60 Hz (AC - 6b)
Max.permissible peak
current Î (kA)
230/240 V 400/415 V 440 V 500/550 V 660/690 V UeUe
40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40°C 55°C 70 °C < 500 V > 500 V
UA 16 7.5 6.7 6 12.5 11.7 10 13.7 13 11 15.5 14.7 12.5 21.5 20 17 1.8 1.6
UA 26 12 11 8.5 20 18.5 14.5 22 20 16 22 22 19.5 30 30 25 3 2.7
UA 30 16 16 11 27.5 27.5 19 30 30 20 34 34 23.5 45 45 32 3.5 3.1
UA 50 20 20 19 33 33 32 36 36 35 40 40 40 55 55 52 5 4.5
UA 63 25 25 21 45 43 37 50 48 41 50 50 45 70 70 60 6.5 5.8
UA 75 30 30 22 50 50 39 55 53 43 62 62 47.5 75 75 65 7.5 6.75
UA 95 35 35 29 60/65* 60/65* 50/55* 65 65 55 70 70 60 86 86 70 9.3 8
UA 110 40 39 34 74 70/75* 65 75 75 67 80 80 75 90 90 85 10.5 9
(*) Use these values for Ue= 415 V
For 220 V and 380 V, multiply by 0.9 the rated values at 230 V and 400 V respectively.
Example: 50 kvar/400 V corresponding to 0.9 x 50 = 45 kvar/380 V.
If, in an application, the current peak is greater than the maximum peak current Îspecified in the table above, select a higher rating, refer to the
UA...-R contactors (+ page 2/40) or add inductances (+ Application Guide "Contactors for Capacitor Switching").
The capacitor bank will be protected by gG type fuses whose rating is equal to 1.5 ... 1.8 times nominal current.
Power Max. peak Auxiliary contacts Footprint Weight Order code
400 V current fitted kg
40 °C Ue 500V H W D
kvar kA state coil voltage
12.5 1.8 1 - 74 44 74 0.340 UA 16-30-10
20 3 1 - 90 54 94 0.600 UA 26-30-10
27.5 3.5 1 - 90 54 109 0.710 UA 30-30-10
33 5 1 1 110 82 108 1.200 UA 50-30-11
45 6.5 1 1 110 82 108 1.200 UA 63-30-11
50 7.5 1 1 110 82 108 1.200 UA 75-30-11
60 9.3 1 1 148 102 124 2.040 UA 95-30-11
74 10.5 1 1 148 102 124 2.040 UA 110-30-11
Coil voltages
Voltage Voltage
V - 50Hz V - 60Hz
24 24
48 48
110 110...120
220...230 230...240
230...240 240...260
380...400 400...415
400...415 415...440
(1) Not for EK 370 ... EK 1000 contactors.
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/31
UA...-R 3-pole Contactors
for Capacitor Switching
Peak Current Î 100 Times the rms Current
Application
The UA ...-R contactors can be used in installations in which peak current far exceeds 100 times nominal rms current. The contactors are
delivered complete with their damping resistors and must be used without additional inductances (+ table below).
The kvar ratings acc. to the table below are applicable to "star" connected capacitors (less current, cable savings).
The capacitors must be discharged (maximum residual voltage at terminals < 50 V) before being re-energized when the contactors are making.
Their electrical durability is 250 000 operating cycles for Ue< 500 V and 100 000 operating cycles for Ue 500 V.
Selection Table
Type Powers in kvar - 50/60 Hz (AC-6b)
Max. permissib
le
gG type
220/240 V 380/400/415 V 440 V 500/550 V 660/690 V
peak current
fuses
40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C 40 °C 55 °C 70 °C
Îmax. (*)
UA 16-30-10-R 8 7.5 6 12.5 12.5 10 15 13 11 18 16 12.5 22 21 17 80
UA 26-30-10-R 12.5 11.5 9 22 20 15.5 24 20 17 30 25 20 35 31 26 125
UA 30-30-10-R 16 16 11 30 27.5 19.5 32 30 20.5 34 34 25 45 45 32 200
UA 50-30-00-R 25 24 20 40 40 35 50 43 37 55 50 46 72 65 60 200
UA 63-30-00-R 30 27 23 50 45 39 55 48 42.5 65 60 50 80 75 65 200
UA 75-30-00-R 35 30 25 60 50 41 65 53 45 75 65 55 100 80 70 200
(*) The fuse ratings given in this column represent the maximum ratings ensuring type 1 co-ordination according to the definition of standard IEC 60947-4-1.
Power Auxiliary contacts Footprint Weight Order code
400 V fitted kg
40 °C H W D
kvar state coil voltage
12.5 1 - 140 44 106 0.460 UA 16-30-10-R
22 1 - 140 54 125 0.710 UA 26-30-10-R
30 1 - 140 54 140 0.810 UA 30-30-10-R
40 - - 160 70 139 1.350 UA 50-30-00-R
50 - - 160 70 139 1.350 UA 63-30-00-R
60 - - 160 70 139 1.350 UA 75-30-00-R
Coil voltages
Voltage Voltage
V - 50Hz V - 60Hz
24 24
48 48
110 110...120
220...230 230...240
230...240 240...260
380...400 400...415
400...415 415...440
please contact us for other voltages
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/32
Location of side-mounted accessories
(on right or left hand side).
Terminals delivered in open position with
captive screws.
Screwdriver guidance for all terminals.
Degree of protection of terminals according
to IEC 60947-1: IP 20 for all terminal.
Holes for screw fixing (screws not supplied).
Distance between holes according to
EN 50002.
Location of surge suppressors.
Clear marking of coil voltages and
frequencies.
Terminal marking according to
IEC 60947-5-1, and EN 50011.
Location of function marker.
Stops for attaching front-mounted
accessories.
Quick fixing on mounting rail according
to IEC 715 and EN 50022 standards:
35 x 7.5 mm or 35 x 15 mm.
Terminal screws: Pozidriv (+,-) No. 2.
Number of contacts Footprint Weight Order code
kg
H W D state coil voltage
4-pole, 1-stack
2 2 74 44 74 0.340 N 22 E
3 1 74 44 74 0.340 N 31 E
4 74 44 74 0.34 N 40 E
Coil voltages
Voltage Voltage
V - 50Hz V - 60Hz
24 24
48 48
110 110 ... 120
220 ... 230 230 ... 240
230 ... 240 240 ... 260
380 ... 400 400 ... 415
400 ... 415 415 ... 440
N... Contactor Relays
a.c. Operated
Application
N... contactor relays are used for switching auxiliary circuits and control circuits.
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/33
N/KC... Contactor Relays
Main Accessories
CA 5-10 CAL 5-11
TP 40 DA
VE 5-1
RC 5-1/50RV 5/50
Auxiliary Contact Blocks
Mounting on Positioning Contacts Weight Order Code
contactor kg
relays
N/KC... Front face 1 0.014 CA 5-10
1 0.014 CA 5-01
4 0.060 CA 5-40 N
2 2 0.060 CA 5-22 N
4 0.060 CA 5-04 N
N Side 1 1 0.050 CAL 5-11
Pneumatic Timers
Mounting on Timing range Contacts Weight Order Code
contactor kg
relays
N/KC... Direct 0.1 ... 40 s 1 1 0.070 TP 40 DA
Direct 10 ... 180 s 1 1 0.070 TP 180 DA
Inverse 0.1 ... 40 s 1 1 0.070 TP 40 IA
Inverse 10 ... 180 s 1 1 0.070 TP 180 IA
Interlocks
Mounting on Feature Contacts Weight Order Code
contactor kg
relays
N... Mech. / electrical 2 0.076 VE 5-1
Mechanical 0.066 VM 5-1
KC Mechanical - - 0.015 VBC30
Surge Suppressors
Mounting on Feature Voltage range Weight Order Code
contactor kg
relays
N... Varistor 24 ... 50 V a.c./d.c. 0.015 RV 5/50
50 ... 133 V a.c./d.c. 0.015 RV 5/133
110 ... 250 V a.c./d.c. 0.015 RV 5/250
250 ... 440 V a.c./d.c. 0.015 RV 5/440
RC 24 ... 50 V a.c. 0.012 RC 5-1/50
50 ... 133 V a.c. 0.012 RC 5-1/133
110 ... 250 V a.c. 0.012 RC 5-1/250
250 ... 440 V a.c. 0.012 RC 5-1/440
Other accessories
A wide range of accessories are available:
– various auxiliary contact blocks for specific controls and use,
– interface relays,
– fuse holder blocks,
– function marker.
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/34
KC... Contactor Relays
d.c. Operated with Solid Magnetic Coil
Application
KC... contactor relays are used for switching auxiliary circuits and control circuits.
Number of contacts Footprint Weight Order code
kg
H W D state coil voltage
4-pole, 1-stack
2 2 81 44 114 0.540 KC 22 E
3 1 81 44 114 0.540 KC 31 E
4 81 44 114 0.540 KC 40 E
Coil voltages
Voltage - Uc
V d.c.
12
24
42 Please consult us:
48 For contactor relays with wide range coils
50 For accessories (see pagex/xx)
60
75
110
125
220
240
250
Quick fixing on mounting rail
according to IEC 715 and EN
50022 standards:
35 x 7.5mm or 35 x 15mm
Dove tail anchoring for surge suppressor
assembly.
Clear marking of coil d.c. voltage.
Terminal marking according to
IEC 0947-5-1 and EN 50011 standards.
Terminals delivered in open position with
captive screws.
Screwdriver guidance for all terminals.
Degree of protection of terminals
according to IEC 60947-1:
- Pole terminals: IP20
- Coil terminals: IP20
Location of function marker.
Terminal Screw:
M 3.5 Pozidriv (+, -) Nr 2.
Holes for screw fixing (screws not
supplied). Distance between holes
according to EN 50002.
Stops for attaching front-mounted
accessories
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/35
Contactor Spares
a.c. Operated coils for A9...A300 contactors and N contactor relays
For contactors Weight (kg) Order Code
A9...A16 : UA16 : UA16..-R : N 0.093 ZA16
A26...A40 : UA26, UA30, UA26..-R, UA30..-R 0.148 ZA40
A45...A75 : UA50...UA75, UA50...-R to UA75..-R; GA75 0.166 ZA75
A95...A110 ; UA95...UA110 0.170 ZA110
A145...A185 0.180 ZA185
A210...A300 0.400 ZA300
a.c./d.c. Operated coils c/w electronic interface for AF 45...AF750 contactors
For contactors Weight (kg) Order Code
AF45...AF75 0.170 ZAF75
AF95, AF110 0.200 ZAF110
AF145...AF185 0.225 ZAF185
AF210...AF300 0.450 ZAF300
AF400...AF460 0.525 ZAF460
AF580...AF750 1.335 ZAF750
d.c. Operated coils for AE9...AE110 contactors
For contactors Weight (kg) Order Code
AE9...AE16 0.093 ZAE16
AE26...AE40 0.148 ZAE40
a.c. or d.c. coils only
For contactors Weight (kg) Order Code
EK110, EK150 0.360 KH210
EK175, EK210 0.440 KH300
EK370, EK550, EK1000 0.950 KH800
Sets including a d.c. coil, an economy resistor and an insertion contact
For contactors Weight (kg) Order Code
EK110, 150 0.450 KP210
EK175, 210 0.550 KP300
EK370, EK550, EK1000 1.060 KP800
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/36
Contactor Spares
Main contact sets for 3-pole Contactors
The contact sets for 3-pole contactors consist of six fixed contacts, three moving contacts, springs
and the necessary screws.
For contactors Weight (kg) Order Code
A/AF/AE/TAE 50-30 0.115 ZL50
A/AF/AE/TAE 63-30 0.130 ZL63
A/AF/AE/TAE 75-30 0.145 ZL75
A/AF/AE/TAE 95-30 0.190 ZL95
A/AF/AE/TAE 110-30 0.190 ZL110
A/AF 145 0.380 ZL145
A/AF 185 0.380 ZL185
A/AF 210 0.670 ZL210
A/AF 260 0.670 ZL260
A/AF 300 0.670 ZL300
AF 400 1.320 ZL400
AF 460 1.320 ZL460
AF 580 1.840 ZL580
AF 750 1.840 ZL750
UA 50, UA 50-R 0.115 ZLU50
UA 63, UA 63-R 0.145 ZLU63
UA 75, UA 75-R 0.145 ZLU75
UA 95 0.190 ZLU95
UA 110 0.190 ZLU110
Main contact sets for 4-pole Contactors
The contact sets for 4-pole contactors consist of eight fixed contacts, four moving contacts, springs
and the necessary screws.
For contactors Weight (kg) Order Code
A/AF 45-40 0.150 ZLT45
A/AF 50-40 0.150 ZLT50
A/AF 75-40 0.160 ZLT75
The contact sets for 4-pole contactors consist of eight fixed contacts, four moving contacts, springs
and the necessary screws. In addition, the sets include four moving arcing contacts for
EK370...EK1000 contactors.
For contactors Weight (kg) Order Code
EK 110 0.450 KZK110
EK 150 0.450 KZK150
EK 175 0.700 KZK175
EK 210 0.700 KZK210
EK 370 2.400 KZK370
EK 550 2.400 KZK550
EK 1000 3.000 KZK1000
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/37
Mini contactors B6...B7, BC6...BC7
Ordering details
Rated Aux.
current fitted contacts
AC-3 AC-1
415 V < 40°C Footprint Weight
A A Kw H W D kg Order code
Screw 3 & 4 pole AC operation
1 - 58 53 47 0.18 B6.30.10*
8.5 20 4 - 1 58 53 47 0.18 B6.30.01*
- - 58 53 47 0.18 B6.40.00*
1 - 58 53 47 0.18 B7.30.10*
11.5 20 5.5 - 1 58 53 47 0.18 B7.30.01*
- - 58 53 47 0.18 B7.40.00*
Flat pin 3 & 4 pole AC operation
1 - 58 53 47 0.17 B6.30.10F*
8.5 20 4 - 1 58 53 47 0.17 B6.30.01F*
- - 58 53 47 0.17 B6.40.00F*
1 - 58 53 47 0.17 B7.30.10F*
11.5 20 5.5 - 1 58 53 47 0.17 B7.30.01F*
- - 58 53 47 0.17 B7.40.00F*
Soldering pin 3 pole AC operation
8.5 20 4 1 - 45 48 48 0.17 B6.30.10P*
- 1 45 48 48 0.17 B6.30.01P*
11.5 20 5.5 1 - 45 48 48 0.17 B7.30.10P*
- 1 45 48 48 0.17 B7.30.01P*
Screw 3 & 4 pole DC operation
1 - 58 53 47 0.18 BC6.30.10*
8.5 20 4 - 1 58 53 47 0.18 BC6.30.01*
- - 58 53 47 0.18 BC6.40.00*
1 - 58 53 47 0.18 BC7.30.10*
11.5 20 5.5 - 1 58 53 47 0.18 BC7.30.01*
- - 58 53 47 0.18 BC7.40.00*
Flat pin 3 & 4 pole DC operation
1 - 58 53 47 0.17 BC6.30.10F*
8.5 20 4 - 1 58 53 47 0.17 BC6.30.01F*
- - 58 53 47 0.17 BC6.40.00F*
1 - 58 53 47 0.17 BC7.30.10F*
11.5 20 5.5 - 1 58 53 47 0.17 BC7.30.01F*
- - 58 53 47 0.17 BC7.40.00F*
Soldering pin 3 pole DC operation
8.5 20 4 1 - 45 48 48 0.17 BC6.30.10P*
- 1 45 48 48 0.17 BC6.30.01P*
11.5 20 5.5 1 - 45 48 48 0.17 BC7.30.10P*
- 1 45 48 48 0.17 BC7.30.01P*
*Please state coil voltage/freqency when ordering
B6-30-10
B6-30-10F
B6-30-10P
B7-30-10
B7-40-10
B7-40-10 + CAF6-11
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/38
VB 7-30-01
Rated Aux.
current fitted contacts
AC-3 AC-1
415 V < 40°C Footprint Weight
A A Kw H W D kg Order code
Screw 3 pole AC operation
8.5 20 4 1 - 58 97 47 0.34 VB6.30.10*
- 1 58 97 47 0.34 VB6.30.01*
11.5 20 5.5 1 - 58 97 47 0.34 VB7.30.10*
- 1 58 97 47 0.34 VB7.30.01*
Flat pin 3 pole AC operation
8.5 20 4 1 - 58 97 47 0.34 VB6.30.10F*
- 1 58 97 47 0.34 VB6.30.01F*
11.5 20 5.5 1 - 58 97 47 0.34 VB7.30.10F*
- 1 58 97 47 0.34 VB7.30.01F*
Soldering pin 3 pole AC operation
8.5 20 4 1 - 58 97 47 0.34 VB6.30.10P*
- 1 58 97 47 0.34 VB6.30.01P*
11.5 20 5.5 1 - 58 97 47 0.34 VB7.30.10P*
- 1 58 97 47 0.34 VB7.30.01P*
Screw 3 pole DC operation
8.5 20 4 1 - 58 97 47 0.34 VBC6.30.10*
- 1 58 97 47 0.34 VBC6.30.01*
11.5 20 5.5 1 - 58 97 47 0.34 VBC7.30.10*
- 1 58 97 47 0.34 VBC7.30.01*
Flat pin 3 pole DC operation
8.5 20 4 1 - 58 97 47 0.34 VBC6.30.10F*
- 1 58 97 47 0.34 VBC6.30.01F*
11.5 20 5.5 1 - 58 97 47 0.34 VBC7.30.10F*
- 1 58 97 47 0.34 VBC7.30.01F*
Soldering pin 3 pole DC operation
8.5 20 4 1 - 58 97 47 0.34 VBC6.30.10P*
- 1 58 97 47 0.34 VBC6.30.01P*
11.5 20 5.5 1 - 58 97 47 0.34 VBC7.30.10P*
- 1 58 97 47 0.34 VBC7.30.01P*
Mini contactors VB6...VB7, VBC6...VBC7
Reversing Pairs
* Please state coil voltage/frequency when ordering
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/39
Mini Contactors 3 Pole BC6
Interface Contactors
Rated Aux.
current fitted contacts
AC-3 AC-1
415 V < 40°C Footprint Weight
A A Kw H W D kg Order code
Screw 3 pole DC 24v - 1.4w
8.5 20 4 1 - 58 53 47 0.17 BC6.30.10.1.4*
- 1 58 53 47 0.17 BC6.30.01.1.4*
Flat pin 3 pole DC 24v - 1.4w
8.5 20 4 1 - 58 53 47 0.17 BC6.30.10.F1.4*
- 1 58 53 47 0.17 BC6.30.01.F1.4*
Soldering pin 3 pole DC 24v - 1.4w
8.5 20 4 1 - 45 48 48 0.17 BC6.30.10.P1.4*
- 1 45 48 48 0.17 BC6.30.01.P1.4*
Rated Aux.
current fitted contacts
AC-3 AC-1
415 V < 40°C Footprint Weight
A A Kw H W D kg Order code
Screw 3 pole DC 17 ... 32v - 2.4w
8.5 20 4 1 - 58 53 47 0.18 BC6.30.10.2.4*
- 1 58 53 47 0.18 BC6.30.01.2.4*
Flat pin 3 pole DC 17 ... 32v - 2.4w
8.5 20 4 1 - 58 53 47 0.18 BC6.30.10.F2.4*
- 1 58 53 47 0.18 BC6.30.01.F2.4*
Soldering pin 3 pole DC 17 ... 32v - 2.4w
8.5 20 4 1 - 45 48 48 0.18 BC6.30.10.P2.4*
- 1 45 48 48 0.18 BC6.30.01.P2.4*
Please consult us for 5.5kw version
Return to main indexReturn to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/40
Mini Relays 4 Pole K6/KC6
Ordering details
AC Operation
Screw connection 4 pole Relay
Rated Contact
current fitted Configuration
AC-1
< 40°C Footprint Weight
A H W D kg Order code
4 - 58 53 47 0.18 K6.40E*
20 3 1 58 53 47 0.18 K6.31Z*
2 2 58 53 47 0.18 K6.22Z*
Flat pin connection 4 pole Relay
4 - 58 53 47 0.17 K6.40E-F*
20 3 1 58 53 47 0.17 K6.31Z-F*
2 2 58 53 47 0.17 K6.22Z-F*
Soldering pin connection 4 pole Relay
4 - 45 48 48 0.18 K6.40E-P*
20 3 1 45 48 48 0.18 K6.31Z-P*
2 2 45 48 48 0.18 K6.22Z-P*
DC Operation
Screw connection 4 pole Relay
Rated Contact
current fitted configuration
AC-1
< 40°C Footprint Weight
A H W D kg Order code
4 - 58 53 47 0.18 KC6.40E*
20 3 1 58 53 47 0.18 KC6.31Z*
2 2 58 53 47 0.18 KC6.22Z*
Flat pin connection 4 pole Relay
4 - 58 53 47 0.17 KC6.40E-F*
20 3 1 58 53 47 0.17 KC6.31Z-F*
2 2 58 53 47 0.17 KC6.22Z-F*
Soldering pin 4 pole Relay
4 - 45 48 48 0.17 KC6.40E-P*
20 3 1 45 48 48 0.17 KC6.31Z-P*
2 2 45 48 48 0.17 KC6.22Z-P*
KC6-40E-P
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/41
Accessories for mini contactors
Ordering details
Reversing
connecting link
BSM 6-30
CAF6- 11M
Cover cap LT 6-B
B, BC, K, KC Auxiliary contacts
Mounting on Position Weight Order code
B6.30.10 B7.30.10 1 1 side 0.030 CA6.11M
B6.30.01 B7.30.01 1 1 side 0.030 CA6.11N
B6.40.00 B7.40.00 1 1 side 0.030 CA6.11E
B6.30.10 B7.30.10 1 1 front face 0.035 CAF6.11M
B6.30.10 B7.30.10 2 - front face 0.035 CAF6.20M
B6.30.10 B7.30.10 - 2 front face 0.035 CAF6.02M
B6.30.01 B7.30.01 1 1 front face 0.035 CAF6.11N
B6.30.01 B7.30.01 2 - front face 0.035 CAF6.20N
B6.30.01 B7.30.00 - 2 front face 0.035 CAF6.02N
B6.40.00 B7.40.00 1 1 front face 0.035 CAF6.11E
B6.40.00 B7.40.00 2 - front face 0.035 CAF6.20E
B6.40.00 B7.40.00 - 2 front face 0.035 CAF6.02E
K, KC 1 1 side 0.030 CA6.11K
K, KC 1 1 front face 0.035 CAF6.11K
K, KC 2 - front face 0.035 CAF6.20K
K, KC - 2 front face 0.035 CAF6.02K
Note: Side or front mounted auxiliaries can be fitted, but not together.
B, BC, K, KC Accessories
Description Mounting on Weight kg Order code
with soldering pins B, BC, K, KC 0.014 LB6
with soldering pins CA6.11 0.006 LB6.CA
identification marker front face 0.017 BA-50
protective cover IP20 B, BC, K, KC 0.001 LT6-B
plunger (manual opp) B, BC, K, KC 0.060 BN6
reversing links VB, VBC 0.010 BSM6.30
parallel links B, BC 0.001 LP6
T7 Thermal overloads
Footprint
Setting range A H W D Weight kg Order code
0.10 ... 0.16 55 45 56 0.070 T7DU0.16
0.16 ... 0.24 55 45 56 0.070 T7DU0.24
0.24 ... 0.40 55 45 56 0.070 T7DU0.4
0.40 ... 0.60 55 45 56 0.070 T7DU0.6
0.60 ... 1.0 55 45 56 0.070 T7DU1.0
1.0 ... 1.6 55 45 56 0.070 T7DU1.6
1.6 ... 2.4 55 45 56 0.070 T7DU2.4
2.4 ... 4.0 55 45 56 0.070 T7DU4.0
4.0 ... 6.0 55 45 56 0.070 T7DU6.0
6.0 ... 9.0 55 45 56 0.070 T7DU9.0
9.0 ... 12.0 55 45 56 0.070 T7DU12.0
Note:
1 n/o + 1 n/c auxiliary contact fitted as standard to the overload
Dimension (H) is from the bottom of the contactor to the bottom of the overload
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/42
Manual motor starter Type MS 116 MS 325 MS 450 MS 495
General technical data
Standards: The devices comply with the major 947-1 947-1 947-1 947-1
international, European and national 947-2 947-2 947-2 947-2
regulations IEC 60../EN 60.. 947-4-1 947-4-1 947-4-1 947-4-1
947-5-1 947-5-1 947-5-1 947-5-1
Disconnector characteristics (to IEC/EN 60947-1) yes yes yes yes yes yes yes
Mechanical service life in operations 100.000 100.000 50.000
Permissible ambient temperature
- open °C – 20... + 55/70 1) – 25 ... + 55 1) – 20 ... + 60/70 1)
- encapsulated (in protective housing) °C on request – 25 ... + 40 – 20 ... + 35
- Storage temperature °C – 50 ... + 80 – 50 ... + 80 – 50 ... + 80
Temperature compensation with
Mounting position as illustrated 6) any
Permissible altitude m 3000 3000 2000
Permissible resistance to vibrations 2) 10-150 Hz 10-150 Hz on request on request
(IEC 68-2-6) Amplitude 5 g Amplitude 5 g
Permissible resistance to shocks sinusoidal shock 25 g (11 ms) 15 g (11 ms) on request on request
(IEC 68-2-27)
Mounting (mounting hardware not included in
scope of delivery)
Screw fixing see accessories see accessories 2 x M5 2 x M5
Quick fastening to EN 50022 35 mm 35 mm 35 mm 35 mm,
on top-hat rail (15 mm high)
to EN 50023 75 mm
Electrical connection
of the main conductors (main circuits)
Type Screw terminal Box terminal Box terminal Box terminal
+ bus
Screw Pozidrive size 2 Pozidrive size 2 Pozidrive size 2 Internal hexagon
4 mm
Single-core1 x mm2 1 ... 4 1 ... 10 0.75 ... 35 2.5 ... 70
2 x mm2 1 ... 4 1 ... 4 0.75 ... 25 2.5 ... 50
Stranded1 x mm2 1 ... 4 1 ... 10 0.75 ... 35 2.5 ... 70
2 x mm2 1 ... 4 0.75 ... 25 2.5 ... 50
Flexible1 x mm2 0.75 ... 2.5 1 ... 6 0.75 ... 25 2.5 ... 50
2 x mm2 0.75 ... 2.5 0.75 ... 16 2.5 ... 35
of the auxiliary conductors (auxiliary circuits)
Type Screw Screw Screw
terminal terminal 4) terminal
Screw Pozidrive size 2 Pozidrive size 1 Pozidrive size 2
Single-core1 x mm2 1 ... 2.5 5) 0.5 ... 2.5 0.5 ... 2.5
2 x mm2 1 ... 2.5 0.5 ... 2.5 0.5 ... 2.5
Flexible1 x mm2 0.75 ... 2.5 0.5 ... 2.5 0.5 ... 1.5
2 x mm2 0.75 ... 2.5 0.5 ... 2.5 0.5 ... 1.5
Manual Motor Starters
Type series MS
1) Operating conditions up to 70° C on request 2) G-values refer to the mounting position subject to the highest shock sensitivity
3) Also applies to auxiliary switches HKF1 and undervoltage release UA1 4) For auxiliary switch HKF.. Pozidrive 2
5) Applies to auxiliary switches HK1 and SK1 6) Other mounting posistions on request
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/43
Manual motor starter Type MS 116 MS 325 MS 450 MS 495
General electrical data
Rated insulation voltage Ui
to EN 60947 V AC 690 690 690 690
to CSA / UL / NEMA V AC 600 600 600 600
Rated operating voltage Ueup to V 690 AC/440 DC 690 AC/440 DC 690 AC/440 DC 690 AC/440 DC
Rated impulse strength Uimp kV 6 – / 6 6 6
Rated continuous thermal current Ith A 16 25 50 100
Rated operating current Ie / AC 3 max.
Rated frequency 1) Hz 50/60
Rated current ranges Ie A 0.1 ... 25 11 ... 50 28 ... 100
(number of ranges) (14) (7) (6)
Rated service short-circuit breaking capacity Ics and max. permissible back-up fuses on request
DC rated operating voltage
in the case of series connection
of 3 main circuits
(wiring diagram on request)
DC 1, 60 V A on request 25 50 100
DC 3, 60 V A on request 25 50 100
DC 5, 60 V A on request 25 50 100
Short circuit capacity for DC-rating on request
Auxiliary circuits
Rated operating at AC 15 to 24 V AC A 6 2.5
current Ie 230 V AC A 4 2 3 / 0.5 / 6
400 V AC A 3 1 1.5 / – / 3
1) 2)
at DC 13 to24 V DC A 2 2.5 – / – / –
60 V DC A 2.5 – / 0.15 / –
110 V DC A 0.5 0.6 0.22 / – / 0.5
220 V DC A 0.25 0.25 0.1 / – / 0.25
440 V DC A 0.1 – / – / 0.1
Short-circuit protection back-up fuse gL A on request 10 gL / gG 10 A
aM A 6
1) Correction factors for other frequencies on request
2) On front side 1 changeover contact/on front side 1 NO + 1 NC / at side 1 NO + 1 NC, 2 NO, 2 NC
3) Other data on request
Return to main index
ABB LIMITED 2/44
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Open design, enclosure IP 20, resistant to changeable climates. Quick fastening on mounting rails DIN
EN 50 022, 35 mm without auxiliary switch.
Setting range Weight Order code
A...A kg
MS 116 with thermal and electromagnetic trips, short-circuit-proof up to 50 kA
0.10....0.16 0.268 MS 116 - 0.16
0.16....0.25 0.268 MS 116 - 0.25
0.25....0.40 0.268 MS 116 - 0.4
0.40....0.63 0.268 MS 116 - 0.63
0.63....1.00 0.268 MS 116 - 1.0
1.00....1.60 0.268 MS 116 - 1.6
1.60....2.50 0.268 MS 116 - 2.5
2.50....4.00 0.268 MS 116 - 4
4.00....6.30 0.268 MS 116 - 6.3
6.30....10.00 0.268 MS 116 - 10.0
10.00....16.00 0.268 MS 116 - 16.0
Accessories
Order code
Auxillary switches, for front-panel installation
1 NO + 1 NC HKF1-11
Auxiliary switches, lateral attechment at right
1 NO + 1 NC HK1-11
2 NO HK1-20
2 NC HK1-02
Signal contakt for general “tripped” signal, lateral attachment at right
1 NO + 1 NC SK1-11
2 NO SK1-20
2 NC SK1-02
Undervoltage release, lateral attachment at left
24 V, 50 Hz UA1-24
48 V, 50 Hz UA1-48
60 V, 50 Hz UA1-60
110/120 V, 50/60 Hz UA1-110
208 V, 60 Hz UA1-208
230 V, 50 Hz UA1-230
400 V, 50 Hz UA1-400
415 V, 50 Hz UA1-415
Manual Motor Starter
MS 116
MS 116 with A-contactor
HKF 1-11
MS 116
MS 116 with mini contactor B6
Return to main index
ABB LIMITED 2/45
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
1) For accommodating spindle and attachment to manual motor starter
2) Is screwed directly onto the manual motor starter
Manual Motor Starter
MS116
Accessories
Description Order code
Phase buses for cross wiring MS 116, 63 A, 690 V
for 2 devices without auxiliary switches PS1-2-0
for 3 devices without auxiliary switches PS1-3-0
for 4 devices without auxiliary switches PS1-4-0
for 5 devices without auxiliary switches PS1-5-0
for 2 devices with 1 auxiliary switch PS1-2-1
for 3 devices with 1 auxiliary switch PS1-3-1
for 4 devices with 1 auxiliary switch PS1-4-1
for 5 devices with 1 auxiliary switch PS1-5-1
for 2 devices with 2 auxiliary switches PS1-2-2
for 3 devices with 2 auxiliary switches PS1-3-2
for 4 devices with 2 auxiliary switches PS1-4-2
for 5 devices with 2 auxiliary switches PS1-5-2
Busbar cover BSI-3
Power infeed blocks, 63 A, 690 V, stranded 25 mm2, flexible 16 mm2
flat S1-M1
high S1-M2
Mounted enclosure IP 65, triple lockable in Off position,
with N- und PE-terminal, metric cable gland
Grey enclosure with black handle IB 116-G
Yellow enclosure with red handle IB 116-Y
Switch cubicle mounting kit IP 65, with axial extension
triple lockable in Off position, locked in On position
Twist knob black OHB2AJM
Twist knob red/yellow OHY2AJM
axis 85 mm OXS5X85
axis 105 mm OXS5X105
axis 130 mm OXS5X130
axis 180 mm OXS5X180
driver 1) MSMN
driver spindle 32 mm 2) MSOX
Locking device
lock adapter SA1
locking device assy =(adaptor sai + padlock + 3 keys) SA3
For connecting links between MMS + contactor (see page x/xx)
Return to main index
ABB LIMITED 2/46
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Manual Motor Starter
MS 325
Selection
Open design, enclosure IP 20, resistant to changeable climates. Quick fastening on mounting rails DIN
EN 50 022, 35.
Setting range Weight Order code
A...A kg
MS 325 with thermal and electromagnetic trips,
short-circuit-proof up to 100 kA, resp.50 kA 1) 2)
0.10....0.16 0.347 MS 325 – 0.16
0.16....0.25 0.347 MS 325 – 0.25
0.25....0.40 0.347 MS 325 – 0.4
0.40....0.63 0.347 MS 325 – 0.63
0.63....1.00 0.347 MS 325 – 1
1.00....1.60 0.347 MS 325 – 1.6
1.60....2.50 0.347 MS 325 – 2.5
2.50....4.00 0.347 MS 325 – 4
4.00....6.30 0.347 MS 325 – 6.3
6.30....9.00 0.347 MS 325 – 9
9.00 ....12.50 0.347 MS 325 – 12.5
12.50....16.00 0.347 MS 325 – 16
16.00....20.00 0.347 MS 325 – 20
20.00....25.00 0.347 MS 325 – 25
Magnetic only versions on application
Accessories
Setting range Weight Order code
kg
Auxiliary switches, lateral attachment at left, max. 2 pieces attachable
1 NO + 1 NC 0.031 HK-11
2 NO 0.031 HK-20
2 NC 0.031 HK-02
Signal contact for general “tripped” signal, lateral attachment at the left max. 1 piece attachable
1 NO + 1 NC 0.031 SK-11
Locking device
lock adapter 0.004 SA1
locking device assy. (Adapter SA1 + padlock + 3 keys) 0.050 SA3
For other accessories please consult us.
For connecting links beween MMS and contactor see page ??
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/47
Manual Motor Starters
MS 4xx
Open design. enclosure IP 20, resistant to changeable climates. Quick fastening on mounting rails DIN
EN 50 022, 35 mm without auxiliary switch
Setting range Weight Order code
A . . . A kg
MS 450 with thermal and electromagnetic trips,
tripping class 10, short-circuit-proof up to 50 kA
11....16 0.96 MS 450 – 16
14....20 0.96 MS 450 – 20
18....25 0.96 MS 450 – 25
22....32 0.96 MS 450 – 32
28....40 0.96 MS 450 – 40
36....45 0.96 MS 450 – 45
40....50 0.96 MS 450 – 50
MS 495 with thermal and electromagnetic trips,
tripping class 10, short-circuit-proof up to 50 kA
28....40 2.1 MS 495 – 40
36....50 2.1 MS 495 – 50
45....63 2.1 MS 495 – 63
57....75 2.1 MS 495 – 75
70....90 2.1 MS 495 – 90
80....100 2) 2.1 MS 495 – 100
Magnetic only and heavy duty starving versions on application
Retrofittable accessories
These parts may be procured in addition to the MS 4xx.
They must be mounted by the user.
Type Weight Order code
kg
Auxiliary switches, for front panel installation
1 NO + 1NC 0.02 HK4-11
1 Changeover 0.02 HK4-W
Auxiliary switches, for lateral attachment
at left, max. 1 mountable
1 NO + 1 NC 0.03 HKS4-11
2 NO 0.03 HKS4-20
2 NC 0.03 HKS4-02
Pilot switch, for separate signalling of short-circuit
and general tripping, lateral attachment at left, max. 1
mountable, also together with auxiliary switch
for any signal 1 NO + 1 NC 0.07 SK4-11
For other accessories please consult us.
For connecting links beween MMS and contactor see page ??
Return to main index
ABB LIMITED 2/48
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
BEA 7 ... BEA 110
Connecting Links for Contactors and Manual Motor Starters
A 9-30-10 + BEA 16/116 + MS 116
DOL Starter Combination
BEA 40/450
BEA 16/116
}
}
}
Application
The BEA... connecting link is used for direct linking between a contactor and the associated manual motor
starter which are used together as DOL Starter Combination in type 1 or type 2 co-ordination, complying
with IEC 60947-4-1 and EN 60947-4-1.
Database of co-ordination tables on the ABB Website:
www.abb.com/lowvoltage + left menu: "Low Voltage On-Line" + select: "Support Tools".
Description
The BEA... insulated 3-pole connecting link (touch safe) ensures the electrical linking between the
contactor and the corresponding manual motor starter.
The BEA... connecting links can be used with the A... series contactors (including AF..., AE... versions) and the
MS... manual motor starter as indicated in the table below.
For For Iemax. Weight Order code
contactors & fixing MMS & fixing AC-3 kg
Screws not Screws / rail 400 V
supplied not supplied A
B6, VB6A - MS116 8 0.013 BEA7/116
B7, VB7A - MS116 11 0.013 BEA7/116
B6, VB6A - MS325 15 x 35 mm 8 0.021 BEA7/325
B7, VB7A - MS325 11 0.021 BEA7/325
A 9 MS 116 9 0.020 BEA 16/116
A 12 MS 116 12 0.020 BEA 16/116
A 16 MS 116 15 x 35 mm 16 0.020 BEA 16/116
A 26 2 x M4 MS 116 25 0.024 BEA 26/116
A 9 MS 325 9 0.031 BEA 16/325
A 12 MS 325 12 0.031 BEA 16/325
A 16 MS 325 15 x 35 mm 16 0.031 BEA 16/325
A 26 2 x M4 MS 325 25 0.031 BEA 26/325
A 30 2 x M4 MS 450 2 x M5 32 0.061 BEA 40/450
A 40 2 x M4 MS 450 2 x M5 37 0.061 BEA 40/450
A 50 2 x M4 MS 450 2 x M5 50 0.062 BEA 50/450
A 50 2 x M6 MS 495 2 x M5 50 0.120 BEA 75/495
A 63 2 x M6 MS 495 2 x M5 63 0.120 BEA 75/495
A 75 2 x M6 MS 495 2 x M5 75 0.120 BEA 75/495
A 90 2 x M6 MS 495 2 x M5 90 0.124 BEA 110/495
A 110 2 x M6 MS 495 2 x M5 100 0.124 BEA 110/495
Return to main index
ABB LIMITED 2/49
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
FBP FieldBusPlug
Communicative Motor Starters - Compact Devices
Motorstarter Direct MSD11-FBP
Motor Branch circuit for 1 motor, 1 direction of rotation, IP20.
• Motor protection with thermal and electromagnetic trip
• Compact device with fieldbus-independent interface for connection to FBP fieldbus connector
• 400 V AC, max. 12 A, incl. motor connector, Ics = 10...50 kA
Designation Setting Range Order Code
0.16 A 0.1 - 0.16 A MSD11-FBP.0.16
0.25 A 0.16 - 0.25 A MSD11-FBP.0.25
0.40 A 0.25 - 0.40 A MSD11-FBP.0.4
0.63 A 0.40 - 0.63 A MSD11-FBP.0.63
1.0 A 0.63 - 1.0 A MSD11-FBP.1
1.6 A 1.0 - 1.6 A MSD11-FBP.1.6
2.5 A 1.6 - 2.5 A MSD11-FBP.2.5
4.0 A 2.5 - 4.0 A MSD11-FBP.4.0
6.3 A 4.0 - 6.3 A MSD11-FBP.6.3
10.0 A 6.3 - 10 A MSD11-FBP.10
12.0 A 8 - 12.0 A MSD11-FBP.12
Motorstarter Direct MSR22-FBP
Motor Branch circuit for 1 motor, 2 directions of rotation, IP20.
• Motor protection with thermal and electromagnetic trip
• Compact device with fieldbus-independent interface for connection to FBP fieldbus connector
• 400 V AC, max. 12 A, incl. motor connector, Ics = 10...50 kA
Designation Setting Range Order Code
0.16 A 0.1 - 0.16 A MSR22-FBP.0.16
0.25 A 0.16 - 0.25 A MSR22-FBP.0.25
0.40 A 0.25 - 0.40 A MSR22-FBP.0.4
0.63 A 0.40 - 0.63 A MSR22-FBP.0.63
1.0 A 0.63 - 1.0 A MSR22-FBP.1
1.6 A 1.0 - 1.6 A MSR22-FBP.1.6
2.5 A 1.6 - 2.5 A MSR22-FBP.2.5
4.0 A 2.5 - 4.0 A MSR22-FBP.4.0
6.3 A 4.0 - 6.3 A MSR22-FBP.6.3
10.0 A 6.3 - 10 A MSR22-FBP.10
12.0 A 8 - 12.0 A MSR22-FBP.12
Accessories for Motor Starters MSD11-FBP and MSR22-FBP
Busbar blocks for MSD11-FBP and MSR22-FBP for cross wiring.
Feeder block for busbar blocks MSD11-FBP and MSR22-FBP.
• Current-carrying capacity max.63 A, connection cross-section 25/16mm2multipole/fine-wire
Designation Order Code
Busbar block for 2 devices PS1-2-0
Busbar block for 3 devices PS1-3-0
Busbar block for 4 devices PS1-4-0
Busbar block for 5 devices PS1-5-0
Feeder block, flat design S1-M1
Feeder block, high S1-M2
MSD11-FBP
MSR22-FBP
Return to main index
ABB LIMITED 2/50
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
FBP FieldBusPlug
Communicative Motor Starters with Control Function
Motorstarter Fieldbus Interface MFI21-FBP
Fieldbus interface, IP20, for coupling to manual motor starter MS 325.
• Integrated motor control functions - direct, reverse-start, star-delta starting, diagnostic functions
• Integrated potentiometer, 3 digital inputs, 3 relay outputs, 1 direct-coupled digital input for detection of
switch position of the MS 325
• Fieldbus-independent interface for connection to FBP fieldbus connector
Designation Order Code
Motorstarter Fieldbus Interface MFI21-FBP.0
*) Manual motor starter MS325 and accessories for MS 325, refer to main switch and technology catalogue
Universal Motor Controller UMC22-FBP
Universal motor controller with thermal overload protection 0.2-63A in a single device type.
• Bushing-type current transformer, cable cross-section 25mm2
• Intergrated motor control functions - direct, reverse-start, star-delta starting, servo-drive functions
• Diagnostic functions - overload, phase failure, trip - trip categories 10,20,30
• Integrated storage of parameters and motor data
• 6 digital inputs, 3 relay outputs
• Fieldbus-independent interface for connection to FBP fieldbus connector
Designation Rated motor current Order Code
Universal Motor Controller 0.2 - 63 A UMC22-FBP.0
Accessories for Universal Motor Controller UMC22-FBP
Busbar blocks for MSD11-FBP and MSR22-FBP for cross wiring.
Feeder block for busbar blocks MSD11-FBP and MSR22-FBP.
• Current-carrying capacity max.63 A, connection cross-section 25/16mm2multipole/fine-wire
Designation Order Code
Control Panel ACS100-PAN
MFI 21
UMC 22
Display - UMC 22
Return to main index
ABB LIMITED 2/51
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
FBP FieldBusPlug
Communicative Motor Starters - Compact Devices
(Please consult us for availability of other protocol’s)
AS-i FieldBusPlug Direct
Ready-made AS-i Slave fieldbus interface with various cable lengths.
• Applicable on the MSD11-FBP and on devices with max. 2 input signals and 1 output signal
• Degree of protection IP65, diagnostic LED
Designation Cable Length Order Code
FieldBusPlug
AS-i Direct 0.25 m ASD11-FBP.025
AS-i Direct 0.50 m ASD11-FBP.050
AS-i Direct 1.00 m ASD11-FBP.100
AS-i Direct 5.00 m ASD11-FBP.500
AS-i FieldBusPlug Performance
Ready-made AS-i Slave fieldbus interface with various cable lengths.
• Applicable on all FBP motor starters and devices with max. 4 input signals and 3 output signals
• Degree of protection IP65, diagnostic LED
Designation Cable Length Order Code
AS-i Performance 0.25 m ASP22-FBP.025
AS-i Performance 0.50 m ASP22-FBP.050
AS-i Performance 1.00 m ASP22-FBP.100
AS-i Performance 5.00 m ASP22-FBP.500
Accessories for AS-i Bus Connection
AS-i round cable for bus junctions
Ready-made bus cable with an M12 connector and an open cable end.
• Application on bus junctions such e.g. AS-i couplers or devices with an integrated AS-i interface
Designation Cable Length Order Code
AS-i Round Cable 0.30 m ASF11-FBP.030
with female connector
AS-i Round Cable 0.30 m ASM11-FBP.030
with male connector
AS-i round cable for bus extension
Ready-made bus cable with M12 male and female connectors
Designation Cable Length Order Code
AS-i Extension Cable 1.00 m ASX11-FBP.100
AS-i Extension Cable 3.00 m ASX11-FBP.300
AS-i Extension Cable 5.00 m ASX11-FBP.500
AS-i round cable and accessories for bus extension
Bus cable and coupling accessories
Designation Cable Length Order Code
AS-i Extension Cable 100 m ASC11-FBP.999
AS-i Round Cable, male conn. ASM11-FBP.0
AS-i Round Cable, female conn. ASF11-FBP.0
AS-i Flat-Cable Branch Circuit with M12 socket AST11-FBP.0
AS-i addressing device, power unit, miscellaneous accessories
Designation Order Code
AS-i Addr. Device, incl. plug-in power unit ASA21-FBP.0
Power Unit PS 24V/5A, adjustable Systron PS24/5
Address Signs for FieldBusPlug CAL11-FBP.0
Field Bus Plug Direct
Field Bus Plug Performance
ST04901 ST05001
ST05101
ST05501 ST05701
ST05601
Return to main indexReturn to main index
ABB LIMITED 2/52
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
FBP FieldBusPlug
DeviceNet Fieldbus Connectors and Accessories
(Please consult us for availability of other protocol’s)
DeviceNet FieldBusPlug
Ready-made DeviceNet fieldbus interface with various cable lengths.
• Applicable on all FBP motor starters and other devices
• Degree of protection IP65, diagnostic LED
Designation Cable Length Order Code
FieldBusPlug
DeviceNet 0.25 m DNP21-FBP.025
DeviceNet 0.50 m DNP21-FBP.050
DeviceNet 1.00 m DNP21-FBP.100
DeviceNet 5.00 m DNP21-FBP.500
Accessories for the DeviceNet Bus Connector
DeviceNet round cable for bus junctions
Ready-made bus cable with an M12 connector and an open cable end.
• Application on bus junctions such e.g. DeviceNet couplers or devices with an integrated DeviceNet
interface
Designation Cable Length Order Code
DeviceNet Round Cable 0.50 m DNF11-FBP.050
with female connector
DeviceNet Round Cable 0.50 m DNM11-FBP.050
with male connector
DeviceNet round cable for bus extension
Ready-made bus cable with M12 male and female connectors
Designation Cable Length Order Code
DeviceNet Extension Cable 1.00 m DNX11-FBP.100
DeviceNet Extension Cable 3.00 m DNX11-FBP.300
DeviceNet Extension Cable 5.00 m DNX11-FBP.500
DeviceNet round cable and accessories for bus extension
Bus cable and coupling accessories
Designation Cable Length Order Code
DeviceNet Extension Cable 100 m DNC11-FBP.999
DeviceNet Round Cable, male conn. DNM11-FBP.0
DeviceNet Round Cable, female conn. DNF11-FBP.0
Termination Resistor, Power Unit, Miscellaneous Accessories
Designation Extra Information Order Code
DeviceNet Termination Resistor 120 Ohm DNR11-FBP.120
Power Unit PS 24V/5A, adjustable Systron PS24/5
B10
ST05301
ST05201
ST04801
ST05501
ST05701
ST05401
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/53
Notes
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/54
Softstarters
Description
Softstarters type PS S
ABB’s solid state starter range is used when it is important to have a smooth start-up of various types of motor drives. Instead of switching
directly to full voltage the softstarter ensures a gradual voltage increase.
PS S 03…PS S 25 is a compact solution for small motors. Mounting
is on 35 mm DIN-rail. This small softstarter has a built-in bypass
contact.
PS S 18/30…PS S 300/515 for normal duty applications and
connection both ”In Line” and ”Inside Delta” (compare the connection
with a standard Y/D starter). The result of ”Inside Delta” connection is
a 42 % reduction of the current exposed to the softstarter. It will then
be possible, for example, to start and run a 100 A motor using a 58 A
softstarter.
An optional ”Current limit” function is available. Two signal relays are
built in as standard. This softstarter has a service factor of 1.15, which
means that the maximum operational current is Ie(rated current)
x1.15.
Example: the PS S 18/30 connected in-line has an Ieof 18 A. The
maximum operational current is then 1.15 x 18 A = 20.7 A.
The operator panels for PS S, PS D and PS DH have LED´s, potentiometers and switches for indication and settings.
In-line and inside-delta connection
of PS S 18/30…300/515
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/55
Softstarters
General Technical Data
PS S 03...PS S 25 and PS S 18/30...PS S 300/515
PS S03...PS S 12 PS S 25 PS S 18/30...PS S 300/515
Rated insulation voltage Ui V 630 630 690
Rated operational coltage Ue V 220 - 230 220 - 230 200 - 690
400 - 415 400 - 415 -
480 - 500 480 - 500 -
600 600 -
Starting Capacity at max. 5 x Ie for 5 sec 5 x Ie for 5 sec 4 x Ie for 10 sec
Rated current Ie
Number of starts per hour 62) 62) 305)
Overload capability Overload class A 10 10 10
Service factor % 100 100 115 (PS S 18/30...250/430)
110 (PS S 300/515)
Ambient temperature
During operation ºC -20 – +50 -20 – +50 -25 – +601)
During Storage ºC -40 – +70 -40 – +70 -40 – +70
Degree of protection
Main circuit IP20 IP20 IP20 (PS S 18/30-500...44/76-500)
IP10 (PSS 50/85-500...72/124-500)
IP10 (PS S 18/30-690...75/124-690)
IP00 (PS S 85/147...300/515)
Supply and control circuit IP20 IP20 IP20
Settings
Ramp time during start s 0.5 – 6.5 -+15% 0.5 – 10 -+10% 1 – 30
Ramp time during stop s 0.5 – 8 -+25% 0.5 – 20 -+10% 0 – 30
Initial voltage during start % 0 – 85 -+15% 0.5 – 50 -+5% 30 – 70
Current limit voltage xIe No No 1.5 – 43)
Switch for
Inside delta connection ON/OFF No No Yes
Signal relay
By-pass signal No4) No4) Yes
Fault signal No No Yes
Rated operational voltage Ue V - - 250
Rated thermal current Ith A - - 5
Rated operational current
at AC-15 (Ue=250) A - - 1.5
Signal indication LED
Ready to start/stand by On Green Green Green
Ramping up/down Yellow Yellow (flashing) No
Completed start ramp T.O.R. Yellow Yellow Green
General fault F1 - Red Red
External fault F2 - - Red
1) Above 40ºC, up to max 60ºC, reduce the rated current with 0.8% per ºC.
2) When more than 6 starts per hour are required, contact your sales office.
3) Only if current transformer is connected (accessory).
4) The unit has built in by-pass contacts (AC-53b).
5) Valid for 50% on time and 50% off time. 3.5 x Ie for 7 sec., if other data is required, contact your sales office
Return to main index
ABB LIMITED 2/56
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Soft starters
Soft starter PS S 03…25, PS S18/30…300/515
PS S 03...25 For normal starts
Motor Motor
Rating Rating
230 V 400 V 230 V 400 V Currrent
Pe Pe Pe Pe Ie
kW kW kW kW A Order code
- 1.1 - - 3 PS S 03-400B
- 5.5 - - 12 PS S 12-400B
- 11.0 - - 25 PS S 25-400B
Control Voltage 40-110V AC/DC, 110-440 VAC.
PS S 18/30…142/245 For normal starts
Inline Inside Delta
Motor Motor
Rating Rating
230 V 400 V 500 V 690 V Currrent 230 V 400V 500V 690V Current
Pe Pe Pe Pe Ie Pe Pe Pe Pe Ie
kW kW kW kW A kW kW kW kW A Order code
4 7.5 11 - 18 7.5 15 18.5 - 30 PS S 18/30-500
7.5 15 18.5 - 30 12.5 25 30 - 52 PS S 30/52-500
9 18.5 22 - 37 15 30 37 - 64 PS S 37/64-500
11 22 25 - 44 22 37 45 - 76 PS S 44/76-500
12.5 25 30 - 50 25 45 55 - 85 PS S 50/85-500
15 30 37 - 60 30 55 75 - 105 PS S 60/105-500
18.5 37 45 - 72 37 59 80 - 124 PS S 72/124-500
22 45 55 - 85 40 75 90 - 147 PS S 85/147-500
30 55 75 - 105 55 90 110 - 181 PS S 105/181-500
37 75 90 - 142 75 132 160 - 245 PS S 142/245-500
45 90 110 - 175 90 160 200 - 300 PS S 175/300-500
75 132 160 - 250 132 220 295 - 430 PS S 250/430-500
90 160 200 - 300 160 257 355 - 515 PS S 300/515-500
Code letter for supply voltage is F = 110-120V, 50/60Hz; L = 220-240V 50/60Hz
Code letter dor fault fignal relay is Blank = NO; C = NC
Note: For heavy duty starting and 690V applications. Please Consult Us.
Return to main index
ABB LIMITED 2/57
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Soft starters Accessories
PS S 18/3…300/515
Current transformer for current limit function
To be connected to terminals 11 and 12 on the soft starter.
The setting range (1.5 – 4) corresponds to a multiple of the transformer ratio.
Technical data below shows transformer ratio and number of turns for the primary winding.
Current Transformer For softstarter Weight kg Order Code
60/1 – 2 turns PS S 18/30 0.30 PS CT-60
40/1 – 1 turn PS S 30/52 0.30 PS CT-40
50/1 – 1 turn PS S 37/64 0.30 PS CT-50
60/1 – 1 turn PS S 44/76 0.30 PS CT-60
75/1 – 1 turn PS S 50/85 0.30 PS CT-75
75/1 – 1 turn PS S 60/105 0.30 PS CT-75
100/1 – 1 turn PS S 72/124 0.25 PS CT-100
125/1 – 1 turn PS S 85/147 0.25 PS CT-125
150/1 – 1 turn PS S 105/181 0.25 PS CT-150
200/1 – 1 turn PS S 142/245 0.25 PS CT-200
250/1 – 1 turn PS S 175/300 0.25 PS CT-250
400/1 – 1 turn PS S 250/430 0.25 PS CT-400
400/1 – 1 turn PS S 300/515 0.25 PS CT-400
Cable connectors for Cu cables (set of 3)
Wire range Tightening For softstarter Weight Order Code
torque max. Nm kg
6-185 mm216 PS S 85/147…142/245 0.2 1SDA023354R1
2x(50-1210) mm216 PS S 85/147…142/245 0.3 LZ 185-2C/120
16-240 mm225 PS S 175/300…300/515 0.4 1SDA023368R1
Cable connectors for AI and Cu cables (set of 3)
Wire range Tightening torque For softstarter Weight kg Order Code
35-95 mm213.35 PS S 85/147…142/245 0.1 1SDA023356R1
25-150 mm231 PS S 85/147…142/245 0.1 1SDA023357R1
120-240 mm243 PS S 175/300…300/515 0.1 1SDA023379R1
Terminal shrouds (set of 2)
For softstarter Weight kg Order Code
For cable connectors PS S 85/147…142/245 0.1 LT 185-AC
For compression lugs PS S 85/147…142/245 0.1 LT 185-AL
For cable connectors PS S 175/300…300/515 0.2 LT 300-AC
For compression lugs PS S 175/300…300/515 0.2 LT 300-AL
Terminal nut washer (set of 2)
For softstarter Weight kg Order Code
PS S 85/147…142/245 0.2 LE 185
PS S 175/300…300/515 0.3 LE 300
Terminal shrouds (set of 2)
For softstarter Weight kg Order Code
PS S 18/30...44/76 0.1 PS LW-44
PS S 50/85…72/124 0.15 PS LW-72
PS S 85/147…142/245 0.25 LW 185
PS S 175/300…300/515 0.4 LW-300
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/58
Pilot Devices, Compact Range
non-illuminated
Same front design for both the modular and the
compact range. Robust actuators in clear colors with
large text and push area.
Samples of accessories
Features
Reliable performance
Less stock-keeping
”All-in-one function”
One Order Code = one
complete function
Robust design
Easy mounting
Part of the ABB Family
The compact range can easily be combined with our
modular Pilot Devices as they have the same front
design.
Worldwide availability
ABB is represented in over 130 countries. Our pilot
devices meet all major international and national
standards.
Technical advantages
High degree of protection
One or two built-in
electrically separated
contacts (1NO, 1NC, 2NO, 2NC
or 1NC + 1NO)
Contacts with wiping action
Low built-in depth
42 mm
The compact range is a new
competitive choice for OEM
customers and Panel Builders with
high requirements of cost efficient,
easy to use and reliable products.
Return to main index
ABB LIMITED 2/59
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pilot Devices
Compact Range
Pushbuttons, Non-Illuminated
Contacts Included Momentary *Maintained Momentary *Maintained
No NC Flush button Flush button Extended button Extended button
1 - CP1-10 -10 CP2-10 -10 CP3-10 -10 CP4-10 -10
2 - CP1-10 -20 CP2-10 -20 CP3-10 -20 CP4-10 -20
- 1 CP1-10 -01 CP2-10 -01 CP3-10 -01 CP4-10 -01
- 2 CP1-10 -02 CP2-10 -02 CP3-10 -02 CP4-10 -02
1 1 CP1-10 -11 CP2-10 -11 CP3-10 -11 CP4-10 -11
chrome bezel available on request
Colour Code Letter
Red R Ordering Example
Green G Requested: A compact pushbutton, momentary, with red
Yellow Y extended button and one NO contact.
Blue L Order: 1 piece of CP3-10R-10
White W
Black B
Grey U
Contacts Included Momentary *Maintained
Flush button, white Extended button, black
With black I with black II with white 0
1 - CP1-110W-10 CP1-210W-10 -
- 1 - - CP3-310B-01
Chrome Bezel available on request
*Maintained available Sept 2003 onwards
Return to main index
ABB LIMITED 2/60
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Selector switches, non-Illuminated
Two Position
Contacts Included Maintained Maintained Momentary
No NC
1 - C2SS1-10 -10 C2SS2-10 -10 C2SS3-10 -10
2 - C2SS1-10 -20 C2SS2-10 -20 C2SS3-10 -20
- 1 C2SS1-10 -01 C2SS2-10 -01 C2SS3-10 -01
- 2 C2SS1-10 -02 C2SS2-10 -02 C2SS3-10 -02
1 1 C2SS1-10 -11 C2SS2-10 -11 C2SS3-10 -11
chrome bezel available on request
Colour Code Letter
Red R
Black B
Grey U
Three Position
Contacts Included Maintained Momentary Momentary Momentary
NO NC
2 - C3SS1-10 -20 C3SS2-10 -20 C3SS3-10 -20 C3SS7-10 -20
- 2 C3SS1-10 -02 C3SS2-10 -02 C3SS3-10 -02 C3SS7-10 -02
1 1 C3SS1-10 -11 C3SS2-10 -11 C3SS3-10 -11 C3SS7-10 -11
Ordering Example
Requested: A red compact selector switch with three positions, Momentary, spring return from A to B and
maintained position in C. With 2 NC contacts.
Order: 1 piece of C3SS7-10R-02
Pilot Lights (max. 250V 3W)
Pilot light BA 9s base
Colour Order Code
Red CL-100R
Green CL-100G
Yellow CL-100Y
Blue CL-100L
White CL-100W
Clear CL-100C
Direct supply. Max. 250V 3W. Use filament bulb for best light. Alight diffusing lens is recommended for
use with LED and neon bulbs.
Pilot Devices, Compact Range
BCA C BC
ABCABCABCABC
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/61
Technical Data
Standards
IEC 73, 529, 947-5-1, 947-5-5
EN 50 013, 60 947-5-1
UL 508
CSA C22.2 No. 14
Degree of protection
Operators
Compact pushbutton IP66
Compact pilot lights IP66
Compact selector switch IP66
Electrical functions
Terminals IP20
Mechanical life
Pushbuttons 0.5 million operations
Selector switches 0.5 million operations
Temperature
Ambient temperature during operation -25 to +70 ºC
Storage temperature -30 to +85 ºC
Terminals
Plus-minus Pozidrive Size 2
Connectable area min. 1 x 0.5mm2
max. 2 x 1.5mm2/
2 x AWG14
Contacts
Ratings as per UL, CSA, NEMA C300, R300
Rated insulation voltage 250 V
Rated thermal current 2.5 A
Rated operational current at 120 V 1.5 A
240 V 0.75 A
Ratings as per IEC 947-5-1
Rated insulation voltage 300 V
Rated thermal current, Ith 5 A
Rated operational current Ie
Utilization category AC 15, at 120 V 1.5 A
240 V 1 A
Utilization category DC 13, at 24 V 0.3 A
125 V 0.2 A
Short circuit protection
Max. fuse at 1 kA 16 A ordinary
10 A delayed
Pilot light max. 3W, 240 V
Pilot Devices, Compact Range
Technical data
Extended button
Flush button
Dimensions - Compact Pushbutton
Compact Selector Switch
Compact Pilot Light
Drilling Plan - for pushbuttons, switches and pilot lights
Return to main index
ABB LIMITED 2/62
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Voltages see page xx
Colour Code - Replace * with colour
Contact Blocks see page xx
ORDER EXAMPLE: CBK-CPIF 6R
(illuminated pushbutton c/w lamp block & lamp - 6v Direct -Red)
Colour Code
R = Red
G = Green
Y = Yellow
L= Blue
B = Black 1)
W = White 2)
C = Clear 2)
1) Only available for non-illuminated
pushbuttons
2) Not available for LED lamps
Pushbutton & pilot devices
CBK 22mm
Momentary
Maintained (push on push off)
Maintained (push on push off)
Momentary
Momentary (LED)
Maintained (LED)
(push on push off)
Flush
Extended
Standard & Illuminated Pushbuttons
Description Bezel Type Order Code
Flush button momentary chrome plastic CBK-CP*
Non-illuminated chrome CBK-MP*
Extended button momentary chrome plastic CBK-CPE*
Non-illuminated chrome CBK-MPE*
Flush button maintained chrome plastic CBK-CPP*
Non-illuminated chrome CBK-MPP*
Extended button maintained chrome plastic CBK-CPPE*
Non-illuminated chrome CBK-MPPE*
Full voltage -extended momentary chrome plastic CBK-CPIF *
illuminated pushbutton chrome CBK-MPIF *
c/w lamp block & lamp
Resistor -extended momentary chrome plastic CBK-CPIR *
illuminated pushbutton chrome CBK-MPIR *
c/w lamp block & lamp
Transformer -extended momentary chrome plastic CBK-CPIT *
illuminated pushbutton chrome CBK-MPIT *
Full voltage -extended maintained chrome plastic CBK-CPPIF *
illuminated pushbutton (push-push) chrome CBK-MPPIF *
Resistor - extended maintained chrome plastic CBK-CPPIR *
illuminated pushbutton (push-push) chrome CBK-MPPIR *
Transformer-extended maintained chrome plastic CBKCPPIT *
illuminated pushbutton (push-push) chrome CBK-MPPIT *
Full voltage-extended momentary chrome plastic CBK-CPIFL8 *
illuminated pushbutton chrome CBK-MPIFL8 *
Resistor-extended momentary chrome plastic CBK-CPIRL1 *
illuminated pushbutton chrome CBK-MPIRL1 *
Transformer-extended momentary chrome plastic CBK-CPITL *
illuminated pushbutton chrome CBK-MPITL *
Full voltage -extended maintained chrome plastic CBK-CPPIFL8 *
illuminated pushbutton (push-push) chrome CBK-MPPIFL8 *
Resistor-extended maintained chrome plastic CBK-CPPIRL1 *
illuminated pushbutton (push-push) chrome CBK-MPPIRL1 *
Transformer-extended maintained chrome plastic CBK-CPPITL *
illuminated pushbutton (push-push) chrome CBK-MPPITL *
Note: Black plastic bezels available on request
Return to main index
ABB LIMITED 2/63
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pushbutton & pilot devices
CBK 22mm
Emergency Stop (complies with EN 60947-55)
Description Order Code
40mm Emergency Stop
twist to release KPMT3-20R
pull to release KPMP3-20R
momentary KPM1-20R
60mm Emergency Stop
twist to release KPMT4-20R
pull to release KPMP4-20R
momentary KPM2-20
40mm illuminated Emergency Stop
twist to release KPMT3-21R
pull to release KPMP3-21R
momentary KPM1-21R
60mm illuminated Emergency Stop
twist to release KPMT4-21R
pull to release KPMP4-21R
momentary KPM2-21R
Mushroom and Doubleheaded Pushbuttons.
30mm Mushroom pushbutton
twist to release CBK-PMT3R *
push pull CBK-PMP3R *
momentary CBK-PM3R *
Mushroom lockable pushbutton
40mm maintained (red only) CBK-PMK40R
45mm maintained (red only) CBK-PMKR
Double pushbutton
momentary (start stop) CBK-2P1C
momentary (blank) CBK-2P4C
*Standard actuator colour is RED
if BLACK is required replace R with B
Eg. CBK-PM3B = 30mm mushroom in black
Contact Blocks see page xx
Lamp Blocks see page xx
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/64
3 Position
Standard actuator colour is BLACK
if other colours are required replace *
R = RED G = GREY
Eg. CBK-C2BMKR = 2 pos switch in red
Contact Blocks see page xx
2 Position
Pushbutton & pilot devices
CBK 22mm
Selector switches non-illuminated
Description Bezel Type Order Code
Non-illuminated 2 pos.
short selector switches chrome plastic CBK-C2BMK *
maintained (B&C) chrome CBK-M2BMK *
Non-illuminated 2 pos.
short selector switches chrome plastic CBK-C2BSK *
spring return (C to B) chrome CBK-M2BSK *
Non-illuminated 2 pos.
short selector switches chrome plastic CBK-C2AMK *
maintained (A&C) chrome CBK-M2AMK *
Non-illuminated 2 pos.
long selector switches chrome plastic CBK-C2BML *
maintained (B&C) chrome CBK-M2BML *
Non-illuminated 2 pos.
long selector switches chrome plastic CBK-C2BSL *
spring return (C to B) chrome CBK-M2BSL *
Non-illuminated 2 pos.
long selector switches chrome plastic CBK-C2AML *
maintained (A&C) chrome CBK-M2AML *
Non-illuminated 3 pos.
short selector switches chrome plastic CBK-C3MK *
maintained (A,B&C) chrome CBK-M3MK *
Non-illuminated 3 pos.
short selector switches chrome plastic CBK-C3SK *
spring return (A&C to B) chrome CBK-M3SK *
Non-illuminated 3 pos.
short selector switches chrome plastic CBK-C3SRK *
spring return (C to B)
maintained (A) chrome CBK-M3SRK *
Non-illuminated 3 pos.
long selector switches chrome plastic CBK-C3ML *
maintained (A,B&C) chrome CBK-M3ML *
Non-illuminated 3 pos.
long selector switches chrome plastic CBK-C3SL *
spring return (A&C to B) chrome CBK-M3SL *
Non-illuminated 3 pos.
long selector switches
spring return (C to B) chrome plastic CBK-C3SRL *
maintained (A) chrome CBK-M3SRL *
Note: Black plastic bezels available on request
BC
BC
A C
BC
BC
A C
ABC
ABC
ABC
ABC
ABC
ABC
Return to main index
ABB LIMITED 2/65
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pushbutton & pilot devices
CBK 22mm
2 Position
3 Position
Contact Blocks see page xx
Lamp Blocks see page xx Colour Code - Replace * with colour
R = Red
G = Green
Y = Yellow
L = Blue
Selector switches illuminatec (translucent actuator)
Description Bezel Type Order Code
Illuminated 2 pos.
short selector switches chrome plastic CBK-C2BMKI *
maintained (B&C) chrome CBK-M2BMKI *
Illuminated 2 pos.
short selector switches chrome plastic CBK-C2BSKI *
spring return (C to B) chrome CBK-M2BSKI *
Illuminated 2 pos.
short selector switches chrome plastic CBK-C2AMKI *
maintained (A&C) chrome CBK-M2AMKI *
Illuminated 2 pos.
long selector switches chrome plastic CBK-C2BMLI *
maintained (B&C) chrome CBK-M2BMLI *
Illuminated 2 pos.
long selector switches chrome plastic CBK-C2BSLI *
spring return (C to B) chrome CBK-M2BSLI *
Illuminated 2 pos.
long selector switches chrome plastic CBK-C2AMLI *
maintained (A&C) chrome CBK-M2AMLI *
Illuminated 3 pos.
short selector switches chrome plastic CBK-C3MKI *
fixed (A,B&C) chrome CBK-M3MKI *
Illuminated 3 pos.
short selector switches chrome plastic CBK-C3SKI *
spring return (A&C to B) chrome CBK-M3SKI *
Illuminated 3 pos.
short selector switches
spring return (C to B) chrome plastic CBK-C3SRKI *
maintained (A) chrome CBK-M3SRKI *
Illuminated 3 pos.
long selector switches chrome plastic CBK-C3MLI *
maintained (A,B&C) chrome CBK-M3MLI *
Illuminated 3 pos.
long selector switches chrome plastic CBK-C3SLI *
spring return (A&C to B) chrome CBK-M3SLI *
Illuminated 3 pos.
long selector switches
spring return (C to B) chrome plastic CBK-C3SRLI *
maintained (A) chrome CBK-M3SRLI *
BC
BC
A C
BC
BC
A C
ABC
ABC
ABC
ABC
ABC
ABC
Return to main index
ABB LIMITED 2/66
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
2 Position
3 Position
Contact Blocks see page 2/69
N.B. Different keys are available for the selector switches on request
The standard unit has key Type 71.
For key Type 72 add a "2" at the end of the reference or for key Type 73 add a "3".
Eg. CBK-S2KM1 Key 71.
CBK-S2KM12 Key 72.
CBK-S2KM13 Key 73.
Pushbutton & pilot devices
CBK 22mm
Key operated selector switches
Description Bezel Type Order Code
Key operated 2 pos.
selector switches
maintained, key
removable all pos. chrome CBK-S2KM4
Maintained, key
removable (B) chrome CBK-S2KM1
Momentary, key
removable (B) chrome CBK-S2KS1
Key operated 3 pos.
selector switches
maintained, key
removable all pos. chrome CBK-S3KM4
Momentary, key
removable all pos.
spring ret. from (A & C to B) chrome CBK-S3KS4
Maintained, key
removable (B) chrome CBK-S3KM2
Momentary, key
removable (B)
spring ret. from (A&C to B) chrome CBK-S3KS2
Momentary, key
removable (A)
spring ret. from (C to B) chrome CBK-S3KSR1
Key operated maintained
pushbutton, locks when
depressed release via key.
Key removable both positions. chrome CBK-PKM1
BC
BC
BC
ABC
ABC
ABC
ABC
ABC
Return to main index
ABB LIMITED 2/67
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pushbutton & pilot devices
CBK 22mm
Pilot Lights
Voltage Description Order Code
6V lamp & lamp block CBK-KLF6 *
12V lamp & lamp block CBK-KLF7 *
24V lamp & lamp block CBK-KLF8 *
48V lamp & lamp block CBK-KLF9 *
120V lamp & lamp block CBK-KLF1 *
110/60V lamp, lamp block & resistor CBK-KLR1 *
240/120V lamp, lamp block & resistor CBK-KLR2 *
110/6V lamp, lamp block & transformer CBK-KLT1 *
240/6V lamp, lamp block & transformer CBK-KLT2 *
415/6V lamp, lamp block & transformer CBK-KLT3 *
480/6V lamp, lamp block & transformer CBK-KLT4 *
24V LED lamp & lamp block CBK-KLFL8 *
110/24V LED lamp, lamp block & resistor CBK-KLRL1 *
110/24V LED lamp, lamp block & transformer CBK-KLTL1 *
240/24V LED lamp, lamp block & transformer CBK-KLTL2 *
415/24V LED lamp, lamp block & transformer CBK-KLTL3 *
480/24V LED lamp, lamp block & transformer CBK-KLTL4 *
Lamp Holder
Lamp Holder+
Resistor
Lamp Holder +
Transformer
Filament
Neon
LED
Colour Code
Replace * with colour code
R = Red
G = Green
Y = Yellow
L = Blue
W = White 1)
C = Clear1)
1) Not available for LED lamps
Lamps
Description Order Code
6V filiment CBK-LB6
12V filiment CBK-LB12
24V filiment CBK-LB24
30V filiment CBK-LB30
48V filiment CBK-LB48
60V filiment CBK-LB60
130V filiment CBK-LB1
220V neon (AC only) CBK-LBN2
24V Red LED CBK-LBD8R
24V Green LED CBK-LBD8G
24V Yellow LED CBK-LBD8Y
24V Blue LED CBK-LBD8L
24V Red Flashing LED CBK-LBDRF
24V Green Flashing LED CBK-LBDGF
24V Yellow Flashing LED CBK-LBDYF
Other voltages on request
Return to main index
ABB LIMITED 2/68
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Resistor Type
Diode Block
Lamp Holder +
Transformer
Transformer
Resistor
Pushbutton & pilot devices
CBK 22mm
Pilot light front mounted accessories
Description Order Code
Full Voltage (maximum 240v) CBK-LMF
110V/60V resistor type CBK-LMR1
240V/120V resistor type CBK-LMR2
24V 1) resistor type CBK-LMR24
110V/24V 2) resistor type CBK-LMLED
110/6V lamp holder + transformer CBK-LMT1
240/6V lamp holder + transformer CBK-LMT2
415/6V lamp holder + transformer CBK-LMT3
480/6V lamp holder + transformer CBK-LMT4
110/24V 2) lamp holder + transformer CBK-LMT124
240/24V 2) lamp holder + transformer CBK-LMT224
415/24V 2) lamp holder + transformer CBK-LMT324
480/24V 2) lamp holder + transformer CBK-LMT424
110/6V transformer CBK-LT1
240/6V transformer CBK-LT2
415/6V transformer CBK-LT3
480/6V transformer CBK-LT4
110/24V 2) transformer CBK-LT124
240/24V 2) transformer CBK-LT224
415/24V 2) transformer CBK-LT324
480/24V 2) transformer CBK-LT424
250V . 1A CBK-CBD
for use with lamps connected to a common lamp test pushbutton
Lamp blocks base mounted accessories
Description Order Code
Full Voltage (maximum 240v) CBK-LMFB
110V/60V resistor type CBK-LMRB1
240V/120V resistor type CBK-LMRB2
24V1) resistor type CBK-LMRB24
120V/24V2) resistor type CBK-LMRLED
1) Designed for electronic circuits 2) Designed for LED 24V lamps
Pilot Heads
Colour Order Code
Red CBK-KAL R
Green CBK-KAL G
Yellow CBK-KAL Y
Blue CBK-KAL L
White CBK-KAL W
Clear CBK-KAL C
Return to main indexReturn to main index
ABB LIMITED 2/69
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pushbutton & pilot devices
CBK 22mm
Actuator
Mounted Blocks
Base
Mounted Blocks
Rear
Mounted Blocks
Contact
Block Holders
Contact blocks
Description Type Contact Order Code
Contact blocks are colour Standard 1 N/O CBK-CB10
coded to easlly identify 1 N/C CBK-CB01
the contact configuration.
GREEN = N/O
RED = N/C
Contact blocks are colour Gold Plated Low 1 N/O CBK-CB10G
coded to easlly identify Energy Contacts 1 N/C CBK-CB01G
the contact configuration.
GREEN = N/O
RED = N/C
Double contact block 2 N/O CBK-CB20
for use with 5 block holder (i.e. outer 2 N/C CBK-CB02
positions) and 3 block holder for 1 N/O + 1 N/C CBK-CB11
selector switches when centre
position is required
Contact Block (rear mounted)
Contact blocks are colour Standard 1 N/O CBK-CBR10
coded to easlly identify 1 N/C CBK-CBR01
the contact configuration.
GREEN = N/O
RED = N/C
Contact blocks are colour Gold Plated Low 1 N/O CBK-CBR10G
coded to easlly identify Energy Contacts 1 N/C CBK-CBR01G
the contact configuration.
GREEN = N/O
RED = N/C
Double contact block for 2 N/O CBK-CB20B
use when 5 contacts are 2 N/C CBK-CB02B
required (i.e. outer positions) 1 N/O + 1 N/C CBK-CB11B
and selector switches when
centre position is required
3 contact block holder CBK-CH
5 contact block holder CBK-H5
Safety holder for Emergency Stop
(3 contact block holder) KCBHS-00
The safety holder can only be used on Emergency Stop Pushbuttons
Return to main index
ABB LIMITED 2/70
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pushbutton & pilot devices
Accessories
Accessories
Protective Membrane
Of transparent, heat and cold resistant rubber.
Does not harden at low temperature. Gives IP 67 degrees of protection. When membrane is used, remove
the gasket.
For operator with Weight (kg) Order Code
Flush button 0.002 CBK-KXB
Extended button 0.002 CBK-KXBE
Double Pushbutton 0.004 CBK-XB2
Mounting Tool
Used for tightening the nut of the attachment device. 0.100 1SFA616920R8015
30mm Adapters
For use when fitting the 22mm pilot devices in 30mm mounting holes. (1.5mm - 4mm panels)
For use with 22mm Compact Pilot Light
Black Plastic 0.010 1SFA616920R8029
Metal 0.035 1SFA616920R8030
Lamp changing tool
Designed for two different lamp diameters. The larger diameter fits filament bulbs and LEDS and the
smaller diameter fits neon bulbs.
Lamp changing tool 0.002 KA1-8072
Legend Plates
Engraved fixed plates with symbol/text
Symbol / text
For Push button Legend plate material Weight Order Code
Off Silver-grey aluminium 0.002 CBK-NPE10
On Silver-grey aluminium 0.002 CBK-NPE11
Start Silver-grey aluminium 0.002 CBK-NPE19
Stop Silver-grey aluminium 0.002 CBK-NPE20
Symbol / text for two-position
selector switch
Centre Right Legend plate material Weight Order Code
Hand Auto Silver-grey aluminium 0.002 CBK-NPE22
Off On Silver-grey aluminium 0.002 CBK-NPE24
Stop Start Silver-grey aluminium 0.002 CBK-NPE25
Symbol / text for three-position selector switch
Left Centre Right Legend plate material Weight Order Code
Hand O Auto Silver-grey aluminium 0.002 CBK-NPE26
Slow Off Fast Silver-grey aluminium 0.002 CBK-NPE27
Blank - Aluminium (1-2 line) CBK-NPE28
Blank - Aluminium (2-3 line) CBK-NPE29
Blank - Plastic (1-2 line) CBK-NPE28P
Blank - Plastic (2-3 line) CBK-NPE29P
Emergency Stop (70mm) CBK-NPE30
Return to main index
ABB LIMITED 2/71
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Pushbutton stations non-metallic IP 54/65
Description Order Code
1 Element enclosure IP65 CBK-EP1
2 Element enclosure IP65 CBK-EP2
3 Element enclosure IP65 CBK-EP3
4 Element enclosure IP65 CBK-EP4
6 Element enclosure IP65 CBK-EP6
1 Element yellow enclosure (only) IP65 CBK-EPY
1 Element complete emergency stop station IP54 CBK-EP1ES40R
c/w twist to release mushroom headed button with 2 n/c contacts
Metallic enclosures available on request
Voltage V Full Voltage Resistor Transformer Full Voltage Resistor Transformer
6 6
12 7
24 8 8 1
48 9
110 1
110/60 1
240/110 2
110/6 1
240/6 2
415/6 3
480/6 4
110/24 1
240/24 2
415/24 3
480/24 4
Filament / Neon LED
Voltage Selection Chart
Pushbutton & pilot devices
Accessories
Return to main index
ABB LIMITED 2/72
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Switching power supplies
CP Range
The switching power supplies CP offer many advantages in comparison to conventional supplies:
• DIN-rail mount compact modules • Constant output voltage with good regulation
• Low weight • cULus listet, UL 1604 class I, Div 2
• High efficiency • EN 50178 (VDE 0160)
• Low Heating • Short-circuit and overload proof
• Wide range of supply voltage • Fused input
Type Supply Voltage Output Voltage Weight Order Code
CP-5/3.0 90 - 260V AC/ 5VDC/3A 0.220 1SVR423418R3000
105 - 260V DC
Frequency, AC input: 47 - 400Hz Inrush current 25ºC ( 2ms): 7.5A
Output load hold time: 10ms at 100% load Internal input fuse: 3.0A(T)
Input current at Output voltage: 5V DC ± 3%
nominal load: 0.4A(90V AC) / 0.2A (260V AC) Output current: 3A
Type Supply Voltage Output Voltage Weight Order Code
CP-6/3.0 90-260VAC/ 6VDC/3A 0.220 1SVR423418R4000
105-260VDC
Frequency, AC input: 47 - 400Hz Inrush current 25ºC ( 2ms): 7.5A
Output load hold time: 10ms at 100% load Internal input fuse: 3.0A(T)
Input current at Output voltage: 6V DC ± 3%
nominal load: 0.5A(90V AC) / 0.25A (260V AC) Output current: 3A
Type Supply Voltage Output Voltage Weight Order Code
CP-12/2.0 90-260VAC/ 12VDC/2A 0.220 1SVR423418R1000
105-260VDC
Frequency, AC input: 47 - 400Hz Inrush current 25ºC ( 2ms): 7.5A
Output load hold time: 10ms at 100% load Internal input fuse: 3.0A(T)
Input current at Output voltage: 12V DC ± 3%
nominal load: 0.6A (90V AC) / 0.27A (260V AC) Output current: 2A
Adjustable output voltage
Type Supply Voltage Output Voltage Weight Order Code
CP-12/2.0 adj 90-260VAC/ 12VDC/2A 0.220 1SVR423418R1100
105-260V DC
Frequency, AC input: 47 - 400Hz Inrush current 25ºC ( 2ms): 33A
Output load hold time: 10ms at 100% load Internal input fuse: 3.0A(T)
Input current at Output voltage: 12V DC ± 3%
nominal load: 0.7A(90V AC) / 0.3A (260V AC) Output current: 2A / 48W
Type Supply Voltage Output Voltage Weight Order Code
CP-24/0.3 adj 90-260VAC/ 12VDC/2A 0.220 1SVR423418R1100
105-260V DC
Frequency, AC input: 47 - 400Hz Inrush current 25ºC ( 2ms): 7.5A
Output load hold time: 10ms at 100% load Internal input fuse: 3.0A(T)
Input current at Output voltage: 24V DC ± 3%
nominal load: 0.2A(90V AC) / 0.1A (260V AC) Output current: 0.3A
CP-5/3.0
CP-24/0.3
Return to main index
ABB LIMITED 2/73
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Switching power supplies
CP Range
Type Supply Voltage Output Voltage Weight Order Code
CP-24/0.5 90 - 260V AC/ 24V DC/0.5A 0.220 1SVR423414R0000
105 - 260V DC
Frequency, AC input: 47 - 440Hz
Output load hold time: 10ms at 100% load
Input current at nominal load: 0.3A (90V AC) / 0.15A (230VAC)
Inrush current 25ºC ( 2ms): 33A
Internal input fuse: 3.0A(T)
Output voltage: 24V DC ± 3%
Output current: 0.5A / 7.2W
Type Supply Voltage Output Voltage Weight Order Code
CP-24/1.0 90 - 260V AC/ 24V DC/1A 0.220 1SVR423418R0000
105 - 260V DC
Frequency, AC input: 47 - 440Hz
Output load hold time: 10ms at 100% load
Input current at nominal load: max. 0.58A (90V AC)
typ. 0.45A (115VAC) typ. 0.27A (230VAC)
Inrush current 25ºC ( 2ms): 7.5A (260V)
Internal input fuse: 3.0A(T)
Output voltage: 24V DC ± 3%
Output current: 1A
Adjustable output voltage
Type Supply Voltage Output Voltage Weight Order Code
CP-24/1.5adj 90 - 260V AC/ 24V DC/1.5A 0.220 1SVR423418R5000
105 - 260V DC
Frequency, AC input: 47 - 440Hz
Output load hold time: 20ms at 100% load
Input current at nominal load: max. 0.8A (90VAC)
typ. 0.7A (117VAC) typ. 0.39A (230VAC)
Inrush current 25ºC ( 2ms): 33A
Internal input fuse: 3.0A(T)
Output voltage: 24V DC ± 3%
Output current: 1.5A / 36W
Type Supply Voltage Output Voltage Weight Order Code
CP-24/2.0 90 - 140V AC 24VDC/2A 0.300 1SVR423417R0000
CP-24/2.0 140V - 260V AC/ 24VDC/2A 0.300 1SVR423417R1000
160 - 260V DC
Frequency, AC input: 47 - 63Hz (90 - 140VAC)
47 - 440Hz (140-260VAC / 160-260VAC)
Output load hold time: 10ms at 100% load
Input current at nominal load: max 1.0A (90V AC) / max. 0.8A (140VAC)
typ. 0.9A (230VAC typ. 0.45A (230VAC)
Inrush current 25ºC ( 2ms): 23A (140VAC / 9A (260VAC)
Internal input fuse: 3.0A(T)
Output voltage: 24V DC ± 3%
Output current: 2A / 48W
CP-24/0.5
Return to main index
ABB LIMITED 2/74
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Switching power supplies
CP Range
Adjustable output voltage
Type Supply Voltage Output Voltage Weight Order Code
CP-24/2.0adj 140 - 260V AC/ 24V DC/2A 0.280 1SVR423417R1100
160 - 260V DC
Frequency, AC input: 47 - 440Hz
Output load hold time: 10ms at 100% load
Input current at nominal load: max. 1.5A (90V AC)
typ. 1.1A (115V AC) typ. 0.52A(230VAC)
Inrush current 25ºC ( 2ms): 40A (260V)
Internal input fuse: 2.0A(T)
Output voltage: 24V DC ± 3%
Output current: 2A / 48W
Type Supply Voltage Output Voltage Weight Order Code
CP-24/4.2 90 - 260V AC/ 24V DC/4.2A 0.580 1SVR423416R1000
127 - 260V DC
Frequency, AC input: 47 - 63Hz
Output load hold time: 20ms at 100% load
Input current at nominal load: max. 1.5A (90V AC)
typ. 1.1A (115VAC) typ. 0.52A (230VAC)
Inrush current 25ºC ( 2ms): 40A (260V)
Internal input fuse: 2.0A(T)
Output voltage: 24V DC ± 3%
Output current at T 55ºC: Vin 90-260VAC - 4.2A / Vin 127-260VAC - 4.2A
Type Supply Voltage Output Voltage Weight Order Code
CP-24/5.0 90 - 260V AC/ 24VDC/5.0A 0.580 1SVR423416R0000
127 - 260V DC
Frequency, AC input: 47 - 63Hz
Output load hold time: 10ms at 100% load
Input current at nominal load: max. 1.8A (90VAC)
typ. 1.3A (115VAC) typ. 0.63A (230VAC)
Inrush current 25ºC ( 2ms): 40A (260V)
Internal input fuse: 2.0A(T)
Output voltage: 24V DC ± 3%
Output current: T 40ºC T > 40ºC T = 55ºC
Vin > 45ºC 5A - 0.054A/ºC 4.2A
Vin < 90VDC or < 140VAC 5A - 0.054A/ºC 4.2A
Adjustable output voltage
Type Supply Voltage Output Voltage Weight Order Code
CP-24/5.0 adj 90V - 260V AC/ 24VDC/5A 0.580 1SVR423416R0100
127 - 260V DC
Frequency, AC input: 47 - 63Hz
Output load hold time: 10ms at 100% load
Input current at nominal load: max 1.8A (90V AC)
typ. 1.3A (115VAC typ. 0.63A (230VAC)
Inrush current 25ºC ( 2ms): 40A (260V)
Internal input fuse: 2.0A(T)
Output voltage: 24VDC ± 3%
(23-28VDC adjustable with poti., max. 120W)
Output current: T 40ºC T > 40ºC T = 55ºC
Vin > 45ºC 5A/120W - 1.33W/ºC 4.2A/100W
Vin < 90VDC or < 140VAC 5A/120W - 1.33W/ºC 4.2A/100W
CP-24/2.0 adj
CP-24/4.2
CP-24/5.0 adj
Return to main index
ABB LIMITED 2/75
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Switching power supplies
CP Range
Adjustable output voltage
Type Supply Voltage Output Voltage Weight Order Code
CP-24/10 adj 93 - 132VAC/ 24V DC/10A 1.050 1SVR432415R0000
187 - 264V DC
Frequency, AC input: 47 - 63Hz
Output load hold time: 20ms at 100% load
Input current at nominal load: max. 4.3A (93VAC)
typ. 3.5A (115VAC) typ. 1.7A (230VAC)
Inrush current 25ºC ( 1ms): max. 69A (230V)
Internal input fuse: 4.0A(T)
Output voltage: 24V DC ± 1% (24 - 28VDCadjustable with a screwdriver)
Output current: T 60ºC T > 60ºC T = 70ºC
Vin 93 - 132VAC 10A - 2%/ºC 8A
Vin 187 - 264VDC 10A - 2%/ºC 8A
Redundant module
Type Input current Output current Weight Order Code
CP-RUD 5A max. 5A max. 0.150 1SVR423418R9000
Monitors two CP range power supplies up to 5A current each. If one power supply fails the CP-RUD
automatically switches to the alternative supply without interruption of the load current. Max. voltage 40V.
Adjustable output voltage
Type Supply Voltage Output Voltage Weight Order Code
CP-24/20 adj 93 - 123VAC/ 24V DC/20A 2.200 1SVR423415R1000
187 - 264VAC
Frequency, AC input: 47 - 63Hz
Output load hold time: 15ms at 100% load
Input current at nominal load: max. 8.9A (93VAC)
typ. 7.2A (115VAC) typ. 3.5A (230VAC)
Inrush current 25ºC ( 2ms): max. 65A (230V)
Internal input fuse: 10A(T)
Output voltage: 24VDC ± 1% (28 - 24VDC adjustable with screwdriver)
Output current: T 60ºC T 60ºC T = 70ºC
Vin 93 - 132VAC 20A - 2%/ºC 16A
Vin 187 - 264VDC 20A - 2%/ºC 16A
Type Supply Voltage Output Voltage Weight Order Code
CP-48/.07 90 - 260V AC/ 48V DC/0.7A 0.300 1SVR423418R6000
105 - 260V DC
Frequency, AC input: 47 - 440Hz
Output load hold time: 10ms at 100% load
Input current at nominal load: max 0.8A (90V AC)
typ. 0.7A (115VAC) typ. 0.35A (230VAC)
Inrush current 25ºC ( 2ms): 33A (260V)
Internal input fuse: 3.0A(T)
Output voltage: 48V DC ± 3%
Output current: 0.7A
Tu> 45ºC - 10mA/ºC
Vin < 105VAC/120VDC - 6.667mA/V
CP-24/10 adj
CP-24/20 adj
CP-48/.07
Return to main index
ABB LIMITED 2/76
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Linear power supplies
CP-L Range
All power supplies are DINrail mountable and available with 230V or 115VAC input voltage, and deliver a
stable and regulated DC output voltage with a low residual ripple of ± 1%.
• The ouput is short-circuit and overload protected
• A LED provides status operation
Type Supply Voltage Output Voltage Weight Order Code
CP-L5/1.0 115VAC 5VDC/1A 0.820 1SVR419500R3000
230VAC 5VDC/1A 0.820 1SVR419500R3100
Frequency, AC input: 47 - 63Hz
Mains buffering: min. 5 ms with 100% load
Input current at nominal load: typ. 0.16A, 115V / typ./ 0.08A, 230V
Internal input fuse: 0.2A (T) 115V / 0.125A (T) 230V
Type Supply Voltage Output Voltage Weight Order Code
CP-L12/0.5 115VAC 12VDC/0.5A 0.820 1SVR419501R1000
230VAC 12VDC/0.5A 0.820 1SVR419501R1100
CP-L12/1.0 115VAC 12VDC/1A 0.780 1SVR419501R3000
230VAC 12VDC/1A 0.780 1SVR419501R3100
Frequency, AC input: 47 - 63Hz
Mains buffering: min. 5 ms with 100% load
Input current at nominal load: 0.5A: typ. 0.14A / typ. 0.07A 1A: 0.32A / 0.16 (T)
Internal input fuse: 0.5A: 0.2A(T) / 0.125A (T) 1A: 0.4A (T) / 0.2A (T)
Type Supply Voltage Output Voltage Weight Order Code
CP-L15/0.5 115VAC 15VDC/0.5A 0.820 1SVR419502R1000
230VAC 15VDC/0.5A 0.820 1SVR419502R1100
CP-L15/1.0 115VAC 15VDC/1A 0.780 1SVR419502R3000
230VAC 15VDC/1A 0.780 1SVR419502R3100
Frequency, AC input: 47 - 63Hz
Mains buffering: min. 5 ms with 100% load
Input current at nominal load: 0.5A: typ. 0.14A / typ. 0.07A 1A: 0.35A / 0.175 (T)
Internal input fuse: 0.5A: 0.2A(T) / 0.125A (T) 1A: 0.4A (T) / 0.2A (T)
CP-L
5VDC, 12VDC
15VDC, 24VDC
Return to main index
ABB LIMITED 2/77
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
Linear power supplies
CP-L Range
Type Supply Voltage Output Voltage Weight Order Code
CP-L24/0.25 115VAC 24VDC/0.25A 0.820 1SVR419503R0000
230VAC 24VDC/0.25A 0.820 1SVR419503R0100
CP-L24/0.75 115VAC 24VDC/0.75A 1.050 1SVR419503R2000
230VAC 24VDC/0.75A 1.050 1SVR419503R2100
Frequency, AC input: 47 - 63Hz
Mains buffering: min. 5 ms with 100% load
Input current at nominal load: 0.25A: typ. 0.14A / typ. 0.07A
0.75A: 0.35A / 0.175 (T)
Internal input fuse: 0.25A: 0.2A(T) / 0.125A (T)
0.75A: 0.4A (T) / 0.2A (T)
Type Supply Voltage Output Voltage Weight Order Code
CP-L±12/0.5 115VAC ± 12VDC/0.5A 1.070 1SVR419511R1000
230VAC ± 12VDC/0.5A 1.070 1SVR419511R1100
Frequency, AC input: 47 - 63Hz
Mains buffering: min. 5 ms with 100% load
Input current at nominal load: typ. 0.35A, 115V / typ. 0.16A, 230V
Internal input fuse: 0.4A (T) 115V / 0.2A (T) 230V
Type Supply Voltage Output Voltage Weight Order Code
CP-L±15/0.5 115VAC ± 15VDC/0.5A 1.070 1SVR419512R1000
230VAC ± 15VDC/0.5A 1.070 1SVR419512R1100
Frequency, AC input: 47 - 63Hz
Mains buffering: min. 5 ms with 100% load
Input current at nominal load: typ. 0.35A, 115V / typ. 0.175A, 230V
Internal input fuse: 0.4A (T) 115V / 0.2A (T) 230V
± 12VDC stabilised
± 15VDC stabilised
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/78
Power supplies CP range
Technical Data
Description CP-5/3.0 CP-6/3.0 CP-12/2.0 CP-12/2.0 adj CP-24/0.3
Residual ripple / noise max.50mVpp Max.300mVss max.200mVss max.100mVss
Deviation of ouput with input change max. ±0.5% max. ±0.1% max. ±0.5%
Deviaton of output with static load change max. ±0.5%
Dev. of output with static load change 10 - 90% max. 5%
Short circuit protection overcurrent switch off with autmomatic restart
Overload protection overtemperature and overcurrent switch off
Reset after thermal overload Disconnection of AC power input min. 30 s
Standards, Tests
Electrical safey standards EN 50178 (VDE 0160) / UL 508 / CSA 22.2
Galvanic isolation reliable isolation acc. to IEC 644-1, DINVDE 0106-101
Voltage withstand input <-> output 2.5kVAC, 3 kVAC type test
Clearance and creepage distances overvoltage category 2, pollutoin degree 2
Electromagnetic compatibility (EMC-tests) ESD: EN 61000-4-2 level 3 6/8kV
acc. to EN 50082-2 RF field: EN 61000-4-4 level 3 10V/m
Burst: EN 61000-4-5 level 4 4kV
Surge: EN 61000-4-5 level 3 3kV
Conducted RF: EN 61000-4-6 level 3 10V
Electromagn. compatibility (EMC) acc. to
EN 500081-2, Radiated noise EN 55011 class B class B class B class B class B
Input current harmonics no limitation
Degree of protection terminals IP20 IP20 IP20 IP20 IP20
Degree of protection enclosure IP50 IP30 IP50 IP30 IP50
Protection class 1 1 1 1 1
General Data
Efficiency approx. 84% approx. 82-84% approx. 83-86% approx. 82-86% approx. 83-86%
(90-260VAC) (102-260VAC) (90-260VAC) (140-260VAC)
Status indication green LED, power OK
Operating temperature 0º – +55ºC
Storage temperature -25ºC – +75ºC
Terminals screw terminals, 2 x 14 AWG (2 x 2.5mm2)
Weight approx. 0.22kg (0.49 lb)
Dimensions (W x H x D), mm 45 x 78 x 100
Description CP-24/0.5 CP-24/1.0 CP-24/1.5 CP-24/2.0 CP-24/2.0 adj
Residual ripple / noise max.100mVss max.300mVss max.100mVss
Deviation of ouput with input change max. ±0.5% max. ±0.1% max. ±0.5% max. ±0.2% max. ±0.5%
Deviaton of output with static load change max. ±0.5%
Dev. of output with static load change 10 - 90% max. 5%
Short circuit protection overcurrent switch off with automatic restart
Overload protection overtemperature and overcurrent switch off
Reset after thermal overload disconnection of AC power input min. 30s
Standards, Tests
Electrical safey standards EN 50178 (VDE 0160) / UL508 / CSA 22.2
Galvanic isolation reliable isolation acc. to IEC 664-1, DIN VDE 0106-101
Voltage withstand input <-> output 2.5kVAC, 3kVAC type test
Clearance and creepage distances overvoltage category 2, pollution degree 2
Electromagnetic compatibility (EMC-tests) ESD: EN 61000-4-2 level 3 6/8kV
acc. to EN 50082-2 RF field: EN 61000-4-4 level 3 10V/m
Burst: EN 61000-4-5 level 4 4kV
Surge: EN 61000-4-5 level 3 3kV
Conducted RF: EN 61000-4-6 level 3 10V
Electromagn. compatibility (EMC) acc. to
EN 500081-2, Radiated noise EN 55011 class B class B class B class B class B
Input current harmonics no limitation
Degree of protection terminals IP20 IP20 IP20 IP20 IP20
Degree of protection enclosure IP50 IP50 IP30 IP20 IP30
Protection class 1 1 1 1 1
General Data
Efficiency approx. 84% approx. 82-84% approx. 83-86% approx. 82-86% approx. 83-86%
(90-260VAC) (102-260VAC) (90-260VAC) (140-260VAC)
Status indication green LED, power OK
Operating temperature 0ºC – +55ºC
Storage temperature -25ºC – +75ºC
Terminals screw terminals, 2 x 14AWG (2.5mm2)
Dimensions (W x H x D), mm 22.5 x 78 x 100 45 x 78 x 100 45 x 78 x 100 45 x 78 x 120 45 x 78 x 120
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/79
Power supplies CP range
Technical Data
Description CP-24/4.2 CP-24/5.0 CP-24/5.0 adj CP-48/0.7 CP-24/10 adj CP-24/20 adj
Residual ripple / noise max.200mVss max.300mVss max.50MVss max.100mVss
Deviation of output with input change max.±0.05% max.±0.5% max.±0.2%
Deviation of output with static load change max.5% max.±1.3
(±1.5% parrallel operation)
Short circuit protection overcurrent switch off with automatic restart
Overload protection overtemperature and overcurrent switch off overcurrent limiting
Reset after thermal overload disconnection of ACpower input min. 30s
Overvoltage protection triggerpoint at typ. 140%
nom. output voltage
Parallel operation (option) up to 5 modules (must be enabled
by internal jumper)
Standards, Tests
Electrical safety standards EN 50178 (VDE 0160) EN 50178 (VDE 0160) /
UL 508/ CSA 22.2 EN 9060 / UL 508 / CSA 22.2
Gakvanic isolation EN 60950 IEC 664-1 DIN/ EN 60950 DIN/ EN 60950
reliable isolation acc. to DIN/VDE 0106-101 VDE 0106-101 VDE 0106-101
Voltage withstand input<->output 1.5kVAC, 3kVACtype test 2.5kVAC, 3kVACtype test
3kVAC type test
Clearance and creepage distances overvoltage category 3, overvoltage category 2,
pollution degree 2 pollution degree 2
Electromagn. comp. (EMC tests) to EN 50082-2
ESD: EN 61000-4-2 level 3 6/8kV EN 61000-4-2 level 3 6/8kV
RF Field: EN 61000-4-3 level 3 10V/m EN 61000-4-3 level 3 10V/m
Burst: EN 61000-4-4 level 3 2kV (CP-48/0.7 4kV) EN 61000-4-4 level 3 4kV
Surge: EN 61000-4-5 2kV (CP-48/0.7 3kV) EN 61000-4-5 level 4 2/4kV
Conducted RF: EN 61000-4-6 level 3 10V EN 61000-4-6 level 3 10V
Input current harmonics no limitation
Degree of protection terminals IP20 IP20 IP20 IP20 IP20 IP20
Degree of protection enclosure IP20 IP20 IP20 IP30 IP20 IP20
Protection class 1 1 1 1 1 1
General Data
Efficiency approx. 77-85% approx. 77-85% approx. 77-85% approx. 83-85% typ.90% typ. 88%
(90-260VAC) (90-260VAC) (90-260VAC) (90-260VAC) (230VAC) (230VAC)
Status indication green LED, power OK
Operating temperature 0ºC – +55ºC -25ºC – +70ºC
Storage temperature -25ºC – +75ºC -25ºC – +85ºC
Screw terminals 2x14 AWG (2 x 2.5mm2)14AWG (2.5mm2)
Dimensions ( W x H x D), mm 90 x 78 x 120 45 x 78 x 100 100 x 125 x 125 220 x 125 x 125
Mounting hints Normal position: horizontal onto DIN-rail
Spacing to other modules left 1cm, vertical distances 5 cm both sides min. 5cm,
vertical distances min. 8 cm
Return to main index
www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368551 Facsimile 02476 368401
ABB LIMITED 2/80
Power supplies CP range
Technical Data
Description CP-L5/1.0 CP-L12/0.5 CP-L15/0.5 CP-L24/0.25 CP-L±12/0.5
CP-L12/1.0 CP-L15/1.0 CP-L24/0.75 CP-L±15/0.5
Residual ripple / noise ± 1%
Short circuit protection overcurrent switch off with automatic restart
Overload protection overtemperature and overcurrent switch off
Reset after thermal overload automatic after cooling
Standards, Tests
Electrical safety standards EN 50178 (VDE 0160)
Galvanic isolation reliable isolation EN 60950
Voltage withstand input<->output 4kVAC, 4VAC test
Clearance and creepage distances overvoltage category III
pollution degree 2
Electromagn. compatibility (EMC-test)
ESD: EN61000-4-2 level 3 (6/8kV)
RF fields EN61000-4-3 level 3 (10V/m)
Burst: EN61000-4-4 level 3 (2kV)
Surge: EN61000-4-5 level 3 (2kV)
Conducted RF: EN61000-4-6 level 3 (10V)
Input current harmonics no limiting
Degree of protection
Terminals: IP20
Enlcosures: IP20
Protection class: 2 with external product protection
General Data
Status indication green LED
Operating temperature -20 – +50ºC
Storage temperature -40 – +80ºC
Terminals screw terminals 14AWG (2.5mm2)
Dimensions (W x H x D) 0.25A 100 x 104 x 79mm
Dimensions (W x H x D) 0.25A 100 x 104 x 79mm 135 x 104 x 79mm
Dimensions (W x H x D) 0.25A 135 x 104 x 79mm
Dimensions (W x H x D) 0.25A 100 x 104 x 79mm
Mounting hints Normal position: horizontal onto DIN rail, Spacing to other modules
upper 100mm, lower 50mm, sides 20mm
Return to main index