FW Phase Monitor
Crouzet
Control Relays
112
b
ALLIED Products Not Cataloged Are Available Ñ Call 1-800-433-5700 For Price And Delivery
Control Relays
c
22.5 Wide, DIN Rail/Surface Mount
c
Level, Current, Voltage Control
793-8400. 84870103. Liquid level, pump up or down, 120 VAC, SPDT ............................................................EACH 54.15
793-8402. 84871009. Current control, 0.1 to 10 A, 120 VAC.............................................................................EACH 86.00
793-8403. 84871204. Current control, 10 to 100 A, 120 VAC............................................................................EACH 78.00
793-8404. 26852304. Transformer for 84871204..............................................................................................EACH 21.00
793-8405. 84871102. Current control with attached transformer, 1 to 20 A .....................................................EACH 70.00
793-8406. 84872004. Voltage control, 10 to 600 V, 120 VAC............................................................................EACH 77.90
c
Monitors and Protects Against Phase Loss, Phase
Reversal, and Low Voltage
c
Protection for Three Phase Motors
c
Rugged Construction for Over Voltage and
Transients
c
Economical Motor, Pump and Compressor Protection
The FW has a space saving 48 mm wide DIN rail/surface mount enclosure and LED power on and relay status indication.
Two front dials provide a nominal voltage setting and a time delay for prevention of nuisance tripping. Output relay is
DPDT, 10 amp (resistive).
793-7100. 84873010. 3 ´230 VAC nominal ......................................................................................................EACH 76.95
793-7102. 84873015. 3 ´480 VAC nominal ......................................................................................................EACH 76.95
793-7103. 84873016. 3 ´575 VAC nominal ......................................................................................................EACH 69.00
JR Alternating Relays
c
Duplex Alternating Control
c
SPDT or DPDT Output 10 Amp Relay
c
Selector Switch Version Available
c
Cross-Wired Version Available
793-2009. PJR 110A. 8 pin, SPDT, 110 VAC...................................................................................................... EACH 47.35
793-2010. PJR 24A. 8 pin, SPDT, 24 VAC/VDC..................................................................................................EACH 49.00
793-5529. PJRS 110A. 8 pin, SPDT, 110 VAC with selector switch...................................................................EACH 56.40
793-5530. PJRX 110A. 8 pin, SPDT, 110 VAC cross-wired version...................................................................EACH 50.70
793-5531. LJR2 110A. 11 pin, DPDT, 110 VAC..................................................................................................EACH 55.61
793-5528. LJR2S 110A. 11 pin, DPDT, 110 VAC with selector switch ..............................................................EACH 55.61
Control Relays
c
1
/
16
Din-Sized Enclosure
c
5 Temperature Control Modes
c
Multiple Temperature Range (¡F and ¡C)
c
Auto-Tuning
c
Built-In Alarm
c
Soft Start Function
c
Nema 4X Front Panel
The CTD Series is a temperature controller available in two basic models Ñ the CTD 43 is a single display unit and the
CTD 46 is a dual display unit. Both models have a temperature range of Ð199 to 999 ¡F or Ð199 to 999¡C and will accept J,
K, L, or N type thermocouples and RTDs as temperature sensors. Control modes include ON-OFF or proportioning action
(PID, P, PL, PD). The main output can be programmed for direct (cooling) or inverse (heating) operations and the relay
alarm output programmed to 16 different alarm configurations. The auto-tuning ÒSmartÓ function will calculate and set
automatically the optimum values for the PID mode to insure the closest control of any heating or cooling load.
793-3001. 89421108. CTD 43, Relay output, 110/220 VAC .............................................................................. EACH 214.06
793-3000. 89421118. CTD 43, Transistor output, 110/220 VAC........................................................................EACH 214.06
793-3002. 89421102. CTD 43, Relay output, 24 VAC/VDC ................................................................................EACH 226.83
793-3217. 89421112. CTD 43, Transistor output, 110/220 VAC........................................................................EACH 226.83
793-3003. 89422108. CTD 46, Relay output, 110/220 VAC ...............................................................................EACH 243.40
793-3215. 89422118. CTD 46, Transistor output, 110/220 VAC........................................................................EACH 243.40
793-3216. 89422102. CTD 46, Relay output, 24 VAC/VDC ................................................................................EACH 271.28
793-3218. 89422112. CTD 46, Transistor output, 24 VAC/VDC.........................................................................EACH 271.28
HDU Series Voltage Control Relay and
HDI Series Current Control Relay
c
3 Digit LCD Display
c
Monitors AC and DC Voltages/Current
c
Voltage Control Ñ Type HDUL Measures from 0.2 to 60 V; Type HDUH Measures from 10 to 600 V
c
Current Control Ñ Type HDIL Measures from 2 to 500 mA; Type HDIH Measures from 0.1 to 10 A
Control of AC/DC Current/Voltage without Memory
When the value of the measured current/voltage reaches the threshold, the output relay changes state at the end of a time
delay which can be set on the front face at between 0.1 and 3 seconds. Once the current/voltage drops below 5 to 50% of
the threshold (hysteresis), the output relay changes state again instantly. Changing the hysteresis therefore does not
modify the value of the preset threshold.
Control of AC/DC Current/Voltage with Memory
When the value of the measured current/voltage reaches the threshold, the output relay changes state at the end of a time
delay which can be set on the front face at between 0.1 and 3 seconds and stays locked in this position.
Stock Mfr.Õs Supply Measurement
Type EACH
No. Type Voltage Range
793-2600 84872304 HDUL 120 VAC 0.2 to 60 V 128.25
793-2602 84872306 HDUH 24 VDC 10.0 to 600 V 135.00
793-2604 84872309 HDUH 120 VAC 10.0 to 600 V 128.25
793-2606 84871304 HDIL 120 VAC 2.0 to 500 mA 135.00
793-2608 84871306 HDIH 24 VDC 0.1 to 10 A 135.00
793-2610 84871309 HDIH 120 VAC 0.1 to 10 A 128.25
Current Control Relays
DIRT/LIRT monitors current from 3.5 mA to 7 A VAC and 5 mA to 10 A DC. Purchase transformer (74525305) separately,
below.
793-5519. LIRT 110A. 11 pin, 110 VAC.............................................................................................................. EACH 66.66
793-5520. DIRT 110A. DIN rail, 110 VAC ...........................................................................................................EACH 73.33
793-5539. 74525305. Transformer.....................................................................................................................EACH 22.04
Phase Monitor
Monitors phase loss, reversal, unbalance and low voltage. Versions include 8 and 11 pin plug-in and DIN rail mount. For
3 phase 230 VAC and 480 VAC.
793-8102. PWRL 230A. 8 pin, SPDT, 3 ´230 VAC ............................................................................................EACH 62.20
793-8103. PWRL 480A. 8 pin, SPDT, 3 ´480 VAC ............................................................................................EACH 62.20
793-8105. DWRL 230A. DIN rail, SPDT, 3 ´230 VAC........................................................................................EACH 71.00
793-8106. DWRL 480A. DIN rail, SPDT, 3 ´480 VAC........................................................................................EACH 68.42
Liquid Level Control Relays
Monitors levels of conductive liquid. PNR/PNRU have 4.7 K½ to 100 K½ sensitivity. NNR has 4.7 K½ to 47 K½ sensitivity.
793-2011. PNR 110A. 8 pin, 110 VAC, pump down ...........................................................................................EACH 43.23
793-2012. PNRU 110A. 8 pin, 110 VAC, pump up .............................................................................................EACH 47.35
793-2013. NNR 110A. Open PC board, 11 VAC, pump up or down ...................................................................EACH 36.63
CTD 43 and 46 Series Temperature Controllers
4