DC POWER SUPPLIES
A Greater Measure of Confidence
www.keithley.com
1.888.KEITHLEY (U.S. only)
Series 2290 High Voltage Power Supplies
2290-5 Specifications
5kV Voltage Power Supply Characteristics
CONDITIONS
This document contains specifications and supplemental information for the Model 2290-5
High Voltage Power Supply. Specifications are the standards against which the Model 2290-5 is
tested. Upon leaving the factory, the Model 2290-5 meets these specifications. Characteristics,
supplemental characteristics, and typical values are not warranted, apply at 23°C ±5°C, <70%
relative humidity, and are provided solely as useful information.
CHARACTERISTICS
VOLTAGE RANGE:
Output Voltage1Maximum Output Current Conditions
50 to +5000 V DC 5.000 mA DC No filter
50 to +3000 V DC 5.000 mA DC Filter 1
50 to +5000 V DC 3.000 mA DC Filter 2
VOLTAGE SET ACCURACY2: ±(0.01% of setting + 2.5V).
VOLTAGE DISPLAY ACCURACY: Voltage set accuracy ±1V, typical (±2V, maximum).
VOLTAGE RESOLUTION: 1V (set and display).
VOLTAGE LIMIT RANGE: 0 to 100% full scale.
VOLTAGE REGULATION3: Line: 0.001% for ±10% line voltage change.
Load: 0.005% for 100% load change, typical.
OUTPUT RIPPLE (10kHz–100kHz)4: 0.002% of full scale, VRMS, maximum – No filter.
1.0mVRMS @ 1kV – Filter 1 or Filter 2.
2.0mVRMS @ 3kV – Filter 1 or Filter 2.
3.0mVRMS @ 5kV – Filter 2.
RISE TIME (full load) 6, 7: 1.5 seconds for 0 to within 1V of 5000VDC – No filter.
3 seconds for 0 to within 1V of 3000VDC – Filter 1.
4 seconds for 0 to within 1V of 5000VDC – Filter 2
DISCHARGE TIME (full load) 6, 7: 1 second for 5000VDC to 1VDC – No filter.
3 seconds for 3000VDC to 1VDC – Filter 1.
4 seconds for 5000VDC to 1VDC – Filter 2
DISCHARGE TIME (no load) 6: <12 seconds (to <50VDC) – No filter.
<30 seconds (to <50VDC) – Filter 1 or Filter 2.
SETTLING TIME 6, 7: From 0 to programmed voltage; to within 99.9% of final value within
3 seconds.
RECOVERY TIME 6, 7: 120ms for 40% step change in load current (typical).
Current Limit and Trip Range Voltage Range Filter
0.4 mA to 5.25 mA 0 V to 1.5 kV No filter or Filter 1
0.4 mA to 3.25 mA Filter 2
0.5 mA to 5.25 mA 1.5 kV to 5.0 kV No filter or Filter 1
0.4 mA to 3.25 mA Filter 2
CURRENT SET ACCURACY5: 0.01% ±(0.01% + 2.5µA).
CURRENT RESOLUTION: 1µA.
CURRENT DISPLAY ACCURACY: ±1µA, typical (±2µA, maximum).
STABILITY: ±0.01% per hour; <0.03% per eight hours.
TEMPERATURE DRIFT: 50ppm/ºC, 0º to 40ºC, typical.
PROTECTION: Arc and short circuit protected; programmable voltage and current limits and
current trip.
MONITOR OUTPUTS
OUTPUT SCALE: 0 to +10V to full scale.
CURRENT RATING: 10mA maximum.
OUTPUT IMPEDANCE: <1Ω.
ACCURACY: ±0.2% of full scale with a 100kΩ load, minimum.
UPDATE RATE: 8Hz.
EXTERNAL VOLTAGE SET
INPUT SCALE: 0 to +10V for 0 to full scale.
INPUT IMPEDANCE: 1MΩ.
ACCURACY: ±0.2% of full scale.
UPDATE RATE: 16Hz.
OUTPUT SLEW RATE: <(rise time + 0.3 seconds) for 0 to full range under full load.
GENERAL
INPUT POWER: 55 watts.
2290-5 INPUT VOLTAGE: 120V ±10%, 50 or 60Hz.
2290E-5 INPUT VOLTAGE: 240V ±10%, 50 or 60Hz.
2290J-5 INPUT VOLTAGE: 100V ±10%, 50 or 60Hz.
REAR PANEL CONNECTORS:
SHV male (Kings type 1704-1 or equivalent).
Output high-voltage connector GPIB connector.
BNC Connector (two): Voltage set/Voltage monitor; Current monitor.
TOGGLE SWITCH: Voltage setting or Voltage monitor.
HIGH-VOLTAGE SAFETY INTERLOCK:
Connector: 3-pin press-in connector, 3M part number: 37103-A165-00E-MB.
Pin 1: 5V out, 1.5mA maximum out.
Pin 2: Input: High-voltage output enabled: 3–24V DC.
High-voltage output disabled: <1.2V DC.
Pin 3: Chassis ground through a 100Ω resistor.
INTERFACE PROTOCOL: IEEE-488.1.
OPERATING ENVIRONMENT: 0º to 40ºC; non-condensing.
DIMENSIONS: 89mm high × 206mm wide × 406mm deep (3.5 in. × 8.1 in. × 16 in.).
WEIGHT: 5.5kg (12 pounds).
SAFETY: Conformance to European Union low voltage directive.
WARR ANTY: One year.
WARM-UP TIME: One hour.
1. The output voltage can be programmed to a voltage lower than 50V; however, performance below 50V is not
specified.
2. Add ±2.5VDC when Filter 1 or Filter 2 is enabled.
3. Regulation specifications apply for greater than 25VDC (with full load), or 50VDC (with no load). Below these
values, the unit may not regulate correctly.
4. Peak-to-peak values are within five times the RMS value.
5. Add 2.5µA offset when Filter 1 or Filter 2 is enabled.
6. Times apply with the current limit set to 105% of full scale.
7. Loads are fully resistive.
Model 2290-5 rear panel showing the IEEE-488 interface connector,
high voltage output connector, analog control/output connectors, and
interlock connector.
High voltage power supplies