V19
1
TRG15 SERIES
15W SWITCHING
ADAPTER
Features
* Universal Input Range 90~264Vac
* Meets EN55022 Class B and CISPR/FCC Class B
* Continuous Short Circuit Protection
* Over Voltage Protection
*
Meet CoC Tier 2 & DoE Level VI
(Output Cable Length 1800mm)
(TRG1506: Output Cable Length1220mm)
* No Load Power Consumption<75mw
Ordering information
TR
G
15XX
-
x
-
E
Model No. AC Plug Type DC Plug Type OVP
DC Cable Length and Type
A: USA 2 Pin 01: 720mm
E: Europe 2 Pin 02: 1220mm
U: British 3 Pin 03: 1800mm
S: Australia 2 Pin
11: 720mm with Ferrite Core
12: 1220mm with Ferrite Core
13: 1800mm with Ferrite Core
* 18AWG / UL1185 FOR 5V,7.5V.9V
* 16AWG / UL1185 FOR 6V
* 20AWG/UL1185FOR12V,13.6V,15V,18V,24V
MODEL
OUTPUT
VOLTAGE
OUTPUT
CURRENT
RIPPLE &
NOISE
NOTE 1
VOLTAGE
ACCURACY
NOTE 2
LINE
REGULATION
NOTE 3
LOAD
REGULATION
NOTE 4
AVERAGE
EFFICENCY min.
NOTE 5
TRG1505 5 V 2.0 A 50mVp-p ±2% ±1% ±4% 79%
TRG1506 6 V 1.5 A 60mVp-p ±2% ±1% ±3% 81.57%
TRG1507 7.5 V 1.6 A 75mVp-p ±2% ±1% ±3% 83.26%
TRG1509 9 V 1.4 A 90mVp-p ±2% ±1% ±2% 83.54%
TRG1512 12 V 1.0 A 100mVp-p
±2% ±1% ±2% 83.26%
TRG1512-01
13.6 V 1.0 A 100mVp-p
±2% ±1% ±2% 83.97%
TRG1515 15 V 1.0 A 100mVp-p
±2% ±1% ±2% 84.5%
TRG1518 18 V 0.83 A 100mVp-p
±2% ±1% ±2% 84.48%
TRG1524 24 V 0.63 A 100mVp-p
±2% ±1% ±2% 84.54%
Specifications are subject to change without notice.
V19
2
Specifications
TRG15 Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…......................................................... 90~264Vac
Frequency ………………………………………….……………....... 47 to 63Hz
Input Current ………………….……………..................................... 0.5A max.
Inrush Current ……….................... Cold Start @25 50A max. @ 240Vac
Leakage Current …………………………………………….……. 0.25mA max.
OUTPUT SPECIFICATIONS:
Hold-up Time ………….…………………………………. 10ms typ. @115Vac
Short Circuit Protection …………….………… Hiccup Mode (Auto Recovery)
Over Voltage Protection ………………........... Hiccup Mode (Auto Recovery)
Temperature Coefficient ……………………................................ ±0.05% /
GENERAL SPECIFICATIONS:
Isolation ……………………..……………..… Input to output = 4,242VDC
Operating Temperature ................................ -20 ~ 60(see derating curve)
Storage Temperature ……………………………...….......……........ -20~85
Humidity .................................................... 93% RH max. Non condensing
Cooling ………………………………….………………… Natural Convection
Switching Frequency …………Full Load………………115V / 85KHz Typical
……………………………………………………………...230V / 65KHz Typical
MTBF ….…… MIL-HDBK-217F, GB, at 25/115VAC ……. 200Khrs min.
Altitude ……………………..…………………………….……..……….. 5000m
Dimensions …….……..2.835x2.047x1.378 inches (72.00x52.00x35.00mm))
Weight ……………………………………………………… 140g(0.33 Pounds)
SAFETY AND EMC:
Emission and Immunity ……........ EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety ………………………Class II, IEC60950-01, EN60950-1, UL60950-1
TRG1505, 1506, 1507, 1509, 1512, 1512-01
TRG1515, 1518, 1524
NOTE:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
2. Voltage setpoint at 60% full load.
3. Line regulation measured from 100Vac to 240Vac full load.
4. Load regulation measured from 60% to full load and from 60% to
20% load (60% +/- 40% load).
5. Average Efficiency measured at 25%,50%,75%,100% load and input
voltage is 115Vac / 230Vac.
Mechanical Specification
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified