V19
2
Specifications
TRG15 Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…......................................................... 90~264Vac
Frequency ………………………………………….……………....... 47 to 63Hz
Input Current ………………….……………..................................... 0.5A max.
Inrush Current ……….................... Cold Start @25℃ 50A max. @ 240Vac
Leakage Current …………………………………………….……. 0.25mA max.
OUTPUT SPECIFICATIONS:
Hold-up Time ………….…………………………………. 10ms typ. @115Vac
Short Circuit Protection …………….………… Hiccup Mode (Auto Recovery)
Over Voltage Protection ………………........... Hiccup Mode (Auto Recovery)
Temperature Coefficient ……………………................................ ±0.05% / ℃
GENERAL SPECIFICATIONS:
Isolation ……………………..……………..…… Input to output = 4,242VDC
Operating Temperature ................................ -20 ~ 60℃(see derating curve)
Storage Temperature ……………………………...….......……........ -20~85℃
Humidity .................................................... 93% RH max. Non condensing
Cooling ………………………………….………………… Natural Convection
Switching Frequency …………Full Load………………115V / 85KHz Typical
……………………………………………………………...230V / 65KHz Typical
MTBF ….…… MIL-HDBK-217F, GB, at 25℃/115VAC ……. 200Khrs min.
Altitude ……………………..…………………………….……..……….. 5000m
Dimensions …….……..2.835x2.047x1.378 inches (72.00x52.00x35.00mm))
Weight ……………………………………………………… 140g(0.33 Pounds)
SAFETY AND EMC:
Emission and Immunity ……........ EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety ………………………Class II, IEC60950-01, EN60950-1, UL60950-1
TRG1505, 1506, 1507, 1509, 1512, 1512-01
TRG1515, 1518, 1524
NOTE:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
2. Voltage setpoint at 60% full load.
3. Line regulation measured from 100Vac to 240Vac full load.
4. Load regulation measured from 60% to full load and from 60% to
20% load (60% +/- 40% load).
5. Average Efficiency measured at 25%,50%,75%,100% load and input
voltage is 115Vac / 230Vac.
Mechanical Specification
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified