V19 TRG15 SERIES 15W SWITCHING ADAPTER Features * Universal Input Range 90~264Vac * Meets EN55022 Class B and CISPR/FCC Class B * Continuous Short Circuit Protection * Over Voltage Protection * Meet CoC Tier 2 & DoE Level VI (Output Cable Length 1800mm) (TRG1506: Output Cable Length1220mm) * No Load Power Consumption<75mw Ordering information TRG15XX - x Model No. -XX E DC Plug Type OVP DC Cable Length and Type AC Plug Type XX A: USA 2 Pin 01: 720mm E: Europe 2 Pin 02: 1220mm U: British 3 Pin 03: 1800mm S: Australia 2 Pin 11: 720mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 18AWG / UL1185 FOR 5V,7.5V.9V * 16AWG / UL1185 FOR 6V * 20AWG/UL1185FOR12V,13.6V,15V,18V,24V MODEL OUTPUT OUTPUT RIPPLE & VOLTAGE LINE LOAD AVERAGE VOLTAGE CURRENT NOISE ACCURACY REGULATION REGULATION EFFICENCY min. NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5 TRG1505 5V 2.0 A 50mVp-p 2% 1% 4% 79% TRG1506 6V 1.5 A 60mVp-p 2% 1% 3% 81.57% TRG1507 7.5 V 1.6 A 75mVp-p 2% 1% 3% 83.26% TRG1509 9V 1.4 A 90mVp-p 2% 1% 2% 83.54% TRG1512 12 V 1.0 A 100mVp-p 2% 1% 2% 83.26% 13.6 V 1.0 A 100mVp-p 2% 1% 2% 83.97% TRG1515 15 V 1.0 A 100mVp-p 2% 1% 2% 84.5% TRG1518 18 V 0.83 A 100mVp-p 2% 1% 2% 84.48% TRG1524 24 V 0.63 A 100mVp-p 2% 1% 2% 84.54% TRG1512-01 Specifications are subject to change without notice. 1 V19 Specifications TRG15 Series Derating Curve TRG1505, 1506, 1507, 1509, 1512, 1512-01 INPUT SPECIFICATIONS: Voltage .................................................................................... 90~264Vac Frequency ....................................................................... 47 to 63Hz Input Current .......................................................................... 0.5A max. Inrush Current ............................. Cold Start @25 50A max. @ 240Vac Leakage Current ........................................................... 0.25mA max. OUTPUT SPECIFICATIONS: Hold-up Time ..................................................... 10ms typ. @115Vac Short Circuit Protection ............................ Hiccup Mode (Auto Recovery) Over Voltage Protection ............................. Hiccup Mode (Auto Recovery) Temperature Coefficient ........................................................ 0.05% / TRG1515, 1518, 1524 GENERAL SPECIFICATIONS: Isolation ................................................. Input to output = 4,242VDC Operating Temperature ................................ -20 ~ 60(see derating curve) Storage Temperature ............................................................ -20~85 Humidity .................................................... 93% RH max. Non condensing Cooling ............................................................. Natural Convection Switching Frequency ............Full Load..................115V / 85KHz Typical ........................................................................230V / 65KHz Typical MTBF .......... MIL-HDBK-217F, GB, at 25/115VAC ....... 200Khrs min. Altitude ............................................................................... 5000m Dimensions ...............2.835x2.047x1.378 inches (72.00x52.00x35.00mm)) Weight ............................................................... 140g(0.33 Pounds) SAFETY AND EMC: Emission and Immunity .............. EN55022 Class B, FCC Part 15 Class B EN61000-6-3, EN61000-3-2, EN61000-3-3 EN55024, EN61204-3, EN61000-6-1 Safety ...........................Class II, IEC60950-01, EN60950-1, UL60950-1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 NOTE: 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring @20MHz BW. 2. Voltage setpoint at 60% full load. 3. Line regulation measured from 100Vac to 240Vac full load. 4. Load regulation measured from 60% to full load and from 60% to 20% load (60% +/- 40% load). 5. Average Efficiency measured at 25%,50%,75%,100% load and input voltage is 115Vac / 230Vac.