OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A .4 08/08
Page 2 of 3
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Slotted Optical Switch
OPB818
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Input Diode (see OP240 for additional information)
VF Forward Voltage - - 1.7 V IF = 20 mA
IR Reverse Current - - 100 µA VR = 2 V
Output Phototransistor (see OP550 for additional information)
V(BR)(CEO) Collector-Emitter Breakdown Voltage 30 - - V IC =1 mA
V(BR)(ECO) Emitter-Collector Breakdown Voltage 5 - - V IE = 100 µA
ICEO Collector-Emitter Leakage Current - - 100 nA VCE = 10 V, IF = 0, EE = 0
Coupled
IC(ON) On-State Collector Current 100 - - µA VCE = 10 V, IF = 20 mA
VCE(SAT) Collector-Emitter Saturation Voltage - - 0.4 V IC = 50 µA, IF = 20 mA
Absolute Maximum Ratings (TA=25°C unless otherwi se noted)
Storage & Operating Temperature Range -40°C to +85° C
Lead Soldering Temperature [1/16 inch (1.6 mm) from the case for 5 sec. with soldering iron](1) 260° C
Input Diode
Forward DC Current 50 mA
Peak Forward Current (1 µs pulse width, 300 pps) 1 A
Reverse DC Voltage 2 V
Power Dissipation(2) 75 mW
Output Phototransistor
Collector-Emitter Voltage 30 V
Emitter-Collector Voltage 5 V
Power Dissipation(2) 100 mW
Collector DC Current 30 mA
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 seconds maximum when flow soldering.
(2) Derate linearly 1.67 mW/°C above 25° C.
(3) All parameters were tested using pulse techniques.
(4) Leads are 0.20” square (5.080 mm) and 0.425” long (10.80 mm), minimum.
(5) Methanol or isopropanol are recommended as cleaning agents. Plastic housing is soluble in chlorinated hydrocarbons and
ketones. Spray and wipe; do not submerge.
(6) Polarity is denoted by color of housing top: LED (gray or clear), sensor (black).