Operating Temperature: -55 °C to +125 °C, with voltage derating above 85 °C,
(Max voltage at 125 ºC is 2/3 of the value at 85 ºC)
Working Voltage: 6 to 125 WVdc
Tolerance:±10%, ±20%, ±5%
Capacitance: 1.7 to 2200 µF
Key Features
xThree volts reverse voltage capability
xHigh ripple current capability
xTantalum case
xHermetically sealed
xLow ESR, Low DCL
xExtended range on TAX (M39006/25)
xStandard high vibration and shock requirements on MIL type
Applications
xFiltering, bypass, coupling, energy storage
xLow source impedance circuits
xHigh charging current circuits
Outline Dimensions
Military Types CLR79 and CLR81 and CDE’s commercial
equivalent TAT and TAX, all with Teflon inner-seal, glass-to-
metal hermetic outer-seal, tantalum case construction, have higher
ripple current capability and are more reliable than silver case
units with their risk of short circuit failure from silver whiskers.
The tantalum case with its sintered and anodized cathode
connection affords a 3 V reverse voltage capability, and dc leakage
current as little as 2 µA at 125º C.
Commercial Types TAT for CLR79 and TAX for CLR81
General Specifications
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor
-
et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
Dimensions
Uninsulated Uninsulated Insulated Insulated E
D L D L C A Lead Length Typical
Weight
+ .031, -.016
(+. 79, -. 41)
1 T 1 . 201(5.10) . 475(12. 06) . 232(5.89) . 640(16. 26) .756(19. 20) .025 (. 64) 1.50(38. 10) 2
2 T 2 . 289(7.34) . 632(16. 05) . 314(7.98) . 800(20. 32) .913(23. 19) .025 (. 64) 2.25 (57. 15) 5
3 T 3 . 387(9.83) . 747(18. 97) .418(10. 62) .900(22.86) 1.028(26. 11) .025 (. 64) 2.25 (57. 15) 8
4 T 4 . 387(9.83) 1. 047(26.59) .418(10. 62) 1.200(30. 48) 1.328(33. 73) .025 (. 64) 2.25 (57. 15) 15
Inc hes (m m )
C A SE ± . 016(.41)CDE Size ±.250(±.6.35) (grams)M aximu m Maximu m M aximu m Lead d i a. (No m)
Part Markings
Part Number Nomenclature and Ordering
(Commercial Parts)
TAT 106 M 025 1 2
(1) (2) (3) (4) (5) (6)
(1) Series: TAT (M39006/22), TAX (M39006/25)
(2) Cap code: Expressed in Picofarads (1st two digits significant figures, 3rd digit number of zeros.)
(3) Tolerance: M = ±20%, K= ±10%, J= ±5%
(4) Voltage
(5) Sleeve: 0= No sleeve, 1= Polyester, 2= Polyimide
(6) Case code: 1= T1, 2=T2, 3=T3, 4=T4
(MIL Spec Parts)
Indicate the prefix M39006/22 followed by the appropriate MIL dash number. An example for a M39006/22 in a 100 µF,
±20% tolerance, 30 volts, M level, order as a M39006/22H0113.
Note: Parts without sleeves will not meet the MIL requirements for marking permanency (resistance to solvents).
TAT ±20%
20 µF
125Vdc
00853 Cage Number
0335875
Lot Code
COMMERCIAL PARTS
+ Indicates polarity
Voltage
Capacitance
Series/Cap tol
Date Code by year week,
M39006 Series
22H XXXX
J 000853
100 µF Capacitance
30 Vdc Voltage
0335 Date Code
875 Lot Code
MIL PARTS
(Expressed by yearweek)
+ Indicates polarity
Jan/Cage Number
Dash Number
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
Ratings
TAT(CLR79)
+25° C
+85°C
&
+125°C -55°C +85°C +12C M (1.0) P (0.1) R (0.01)
T AT 306M 00611 30 20 1 9 3. 98 1 2 820 -40 +1 0. 5 +12 0001 0221 044 1
T AT 306K 006 11 30 10 1 9 3. 98 1 2 820 -40 +1 0. 5 +12 0002 0222 044 2
T AT 306J 00611 30 5 1 9 3. 98 1 2 820 -40 +1 0. 5 +12 0003 0223 044 3
T AT 686M 00611 68 20 1 15 3. 16 1 2 960 -40 +14 +16 0004 0224 044 4
T AT 686K 006 11 68 10 1 15 3. 16 1 2 960 -40 +14 +16 0005 0225 044 5
T AT 686J 00611 68 5 1 15 3.16 1 2 960 -40 +14 +16 0006 0226 0446
T AT 147M 00612 14 0 20 2 21 1. 99 1 3 1200 - 40 +14 +16 0007 02 27 0447
T AT 147K 006 12 140 10 2 21 1. 99 1 3 1200 -40 +14 +16 0008 0228 044 8
T AT 147J 00612 140 5 2 21 1. 99 1 3 1200 -40 +14 +16 0009 0229 0449
T AT 277M 00612 27 0 20 2 45 2. 21 1 6.5 1375 -44 +17. 5 +20 0010 0230 0450
T AT 277K 006 12 270 10 2 45 2. 21 1 6. 5 1375 -44 +17. 5 +20 0011 02 31 0451
T AT 277J 00612 270 5 2 45 2. 21 1 6. 5 1375 -44 +17. 5 +20 0012 0232 0452
T AT 337M 00613 33 0 20 3 36 1. 45 2 7.9 1800 -44 +14 +16 0013 0233 0453
T AT 337K 006 13 330 10 3 36 1. 45 2 7. 9 1800 -44 +14 +16 0014 02 34 0454
T AT 337J 00613 330 5 3 36 1. 45 2 7. 9 1800 -44 +14 +16 0015 0235 0455
T AT 567M 00613 56 0 20 3 55 1. 30 2 13 1900 -64 +17. 5 +20 0016 0236 0456
T AT 567K 006 13 560 10 3 55 1. 30 2 13 1900 -64 +17. 5 +20 0017 02 37 0457
T AT 567J 00613 560 5 3 55 1. 30 2 13 1900 -64 +17. 5 +20 0018 0238 0458
T AT 128M 00614 1200 20 4 90 1. 00 3 14 2265 -80 +25 +25 0019 0239 045 9
T AT 128K 006 14 1200 10 4 90 1. 00 3 14 2265 -80 +25 +25 0020 0240 0460
T AT 256M 00811 25 20 1 7. 5 3.98 1 2 820 -40 +10. 5 +12 0021 0241 0461
T AT 256K 008 11 25 10 1 7. 5 3.98 1 2 820 -40 +10. 5 +12 0022 02 42 0462
T AT 256J 00811 25 5 1 7. 5 3.98 1 2 820 -40 +10. 5 +12 0023 02 43 0463
T AT 566M 00811 56 20 1 14 3. 32 1 2 900 -40 +14 +16 0024 0244 046 4
T AT 566K 008 11 56 10 1 14 3. 32 1 2 900 -40 +14 +16 0025 0245 046 5
T AT 566J 00811 56 5 1 14 3.32 1 2 900 -40 +14 +16 0026 0246 0466
T AT 127M 00812 12 0 20 2 20 2. 21 1 2 1220 - 44 +17. 5 +20 0027 02 47 0467
T AT 127K 008 12 120 10 2 20 2. 21 1 2 1220 -44 +1 7. 5 +20 0028 0248 046 8
T AT 127J 00812 120 5 2 20 2. 21 1 2 1220 -44 +17. 5 +20 0029 02 49 0469
T AT 227M 00812 22 0 20 2 37 2. 23 1 7 1370 - 44 +17. 5 +20 0030 02 50 0470
T AT 227K 008 12 220 10 2 37 2. 23 1 7 1370 -44 +1 7. 5 +20 0031 0251 047 1
T AT 227J 00812 220 5 2 37 2. 23 1 7 1370 -44 +17. 5 +20 0032 02 52 0472
T AT 297M 00813 29 0 20 3 34 1. 56 2 6 1770 - 64 +17. 5 +20 0033 02 53 0473
T AT 297K 008 13 290 10 3 34 1. 56 2 6 1770 -64 +1 7. 5 +20 0034 0254 047 4
T AT 297J 00813 290 5 3 34 1. 56 2 6 1770 -64 +17. 5 +20 0035 02 55 0475
T AT 437M 00813 43 0 20 3 46 1. 42 2 14 1825 -64 +17. 5 +20 0036 0256 0476
T AT 437K 008 13 430 10 3 46 1. 42 2 14 1825 -64 +17. 5 +20 0037 02 57 0477
T AT 437J 00813 430 5 3 46 1. 42 2 14 1825 -64 +17. 5 +20 0038 0258 0478
T AT 857M 00814 85 0 20 4 60 0. 94 4 16 2330 -80 +25 +25 0039 0259 0479
T AT 857K 008 14 850 10 4 60 0. 94 4 16 2330 -80 +25 +25 0040 0260 0480
Max Ripple
@ +85°C
40kHz
(mA)
CDE
Comm ercial
Part Num be r
Cap (µF)
Cap
Tol
)
Case
Code
8 Vo l ts M axi mu m at 85°C (5 Vo l ts at 125°C ), Su r g e Vo l ta g e 9. 2 at 85°C
Maximum %
Capacitance change
from Room
Temperature
Part Num ber MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
6 Vo l ts M axi mu m at 85°C (4 Vo l ts at 125°C ), Su r g e Vo l ta g e 6. 9 at 85°C
Max
DF %
Max
ESR
@+25ºC
(ȍ)
Maximum DC
Leakage (µA)
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +12C M (1.0) P (0.1) R (0.01)
T AT 206M 01011 20 20 1 6 3 . 98 1 2 820 -32 +10. 5 +12 0041 02 61 0481
T AT 2 06K 01 011 20 10 1 6 3 . 98 1 2 820 -32 +10. 5 +12 0042 02 62 0482
T AT 206J 01011 20 5 1 6 3 . 98 1 2 820 -32 +10. 5 +12 0043 02 63 0483
T AT 476M 01011 47 20 1 13 3. 67 1 2 855 -36 +14 +16 0044 02 64 0484
T AT 4 76K 01 011 47 10 1 13 3. 6 7 1 2 855 -36 +14 +16 0045 0265 0485
T AT 476J 01011 47 5 1 13 3. 67 1 2 855 -36 +14 +16 0046 0266 0486
T AT 107M 01012 100 20 2 15 1. 99 1 4 1 200 -36 +14 +16 0047 02 67 0487
T AT 1 07K 01 012 100 10 2 15 1. 9 9 1 4 1200 - 36 +14 +16 00 48 02 68 0 488
T AT 107J 01012 100 5 2 15 1. 99 1 4 1200 -36 +14 +16 0049 0269 0489
T AT 187M 01012 180 20 2 30 2. 2 1 1 7 1365 -36 +14 +16 0050 0270 0490
T AT 1 87K 01 012 180 10 2 30 2. 21 1 7 1365 -36 +14 +16 0051 0271 0491
T AT 187J 01012 180 5 2 30 2. 21 1 7 1365 -36 +14 +16 0052 0272 0492
T AT 257M 01013 250 20 3 30 1. 5 9 2 10 1 720 -40 +14 +16 0053 02 73 0493
T AT 2 57K 01 013 250 10 3 30 1. 59 2 10 1720 -40 +14 +16 00 54 02 74 0 494
T AT 257J 01013 250 5 3 30 1. 59 2 10 1 720 -40 +14 +16 00 55 0275 0495
T AT 397M 01013 390 20 3 44 1. 5 0 2 16 1 800 -64 +17. 5 +20 0056 0276 0496
T AT 3 97K 01 013 390 10 3 44 1. 50 2 16 1800 -64 +17. 5 +20 0057 0277 0497
T AT 397J 01013 390 5 3 44 1. 50 2 16 1 800 -64 +17. 5 +20 0058 0278 0498
T AT 757M 01014 750 20 4 50 0. 8 8 4 16 2 360 -80 +25 +25 0059 02 79 0499
T AT 7 57K 01 014 750 10 4 50 0. 88 4 16 2360 -80 +25 +25 00 60 02 80 0 500
T AT 156M 01511 15 20 1 5 4 . 42 1 2 780 -24 +10. 5 +12 0061 0281 0501
T AT 1 56K 01 511 15 10 1 5 4 . 42 1 2 780 -24 +10. 5 +12 0062 0282 0502
T AT 156J 01511 15 5 1 5 4 . 42 1 2 780 -24 +10. 5 +12 0063 0283 0503
T AT 336M 01511 33 20 1 10 4. 02 1 2 820 -28 +14 +16 00 64 0284 0504
T AT 3 36K 01 511 33 10 1 10 4. 0 2 1 2 820 -28 +14 +16 0065 0285 0505
T AT 336J 01511 33 5 1 10 4. 02 1 2 820 -28 +14 +16 00 66 0286 0 506
T AT 706M 01512 70 20 2 13 2. 46 1 4 1150 -28 +14 +16 0067 0287 0507
T AT 7 06K 01 512 70 10 2 13 2. 4 6 1 4 1150 - 28 +14 +16 00 68 02 88 0 508
T AT 706J 01512 70 5 2 13 2. 46 1 4 1150 -28 +14 +16 0069 0289 0509
T AT 127M 01512 120 20 2 18 1. 9 9 1 7 1450 -28 +17. 5 +20 0070 0290 0510
T AT 1 27K 01 512 120 10 2 18 1. 9 9 1 7 1450 - 28 +17. 5 +20 0071 0291 0511
T AT 127J 01512 120 5 2 18 1. 99 1 7 1450 -28 +17. 5 +20 0072 0292 0512
T AT 177M 01513 170 20 3 25 1. 9 5 2 10 1 480 -32 +14 +16 0073 02 93 0513
T AT 1 77K 01 513 170 10 3 25 1. 95 2 10 1480 -32 +14 +16 00 74 02 94 0 514
T AT 177J 01513 170 5 3 25 1. 95 2 10 1 480 -32 +14 +16 00 75 0295 0515
T AT 277M 01513 270 20 3 32 1. 5 7 2 16 1 740 -56 +17. 5 +20 0076 0296 0516
T AT 2 77K 01 513 270 10 3 32 1. 57 2 16 1740 -56 +17. 5 +20 0077 0297 0517
T AT 277J 01513 270 5 3 32 1. 57 2 16 1 740 -56 +17. 5 +20 0078 0298 0518
T AT 547M 01514 540 20 4 40 0. 9 8 6 24 2 330 -80 +25 +25 0079 02 99 0519
T AT 5 47K 01 514 540 10 4 40 0. 98 6 24 2330 -80 +25 +25 00 80 03 00 0 520
T AT 106M 02511 10 20 1 4 5 . 31 1 2 715 -16 +8 +9 0081 03 01 0521
T AT 1 06K 02 511 10 10 1 4 5 . 31 1 2 715 -16 +8 +9 0082 0302 0522
T AT 106J 02511 10 5 1 4 5 . 31 1 2 715 -16 +8 +9 0083 03 03 0523
T AT 226M 02511 22 20 1 6. 6 3. 98 1 2 825 -20 +10. 5 +12 00 84 03 04 0524
T AT 2 26K 02 511 22 10 1 6. 6 3 . 98 1 2 825 -20 +10. 5 +12 0085 0305 0525
Maximum %
Capacitance change
from Room
Tem perature
Part Number MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
Max
DF %
Max ESR
@+25ºC
(ȍ)
Maximum DC
Leakage
A)
Max
Ripple
@ +85°C
40kHz
(mA)
CDE
Comm ercial
Part Numbe r
Cap
F)
Cap
Tol
(±)
Case
Code
15 Vo l ts M ax i mu m at 85°C(10 Vo l ts at 125°C ), Su r g e Vo l tag e 17.2 at 85°C
25 Vo l ts M ax i mu m at 85°C(15 Vo l ts at 125°C ), Su r g e Vo l tag e 28.8 at 85°C
10 Vo l ts M axi mu m at 85°C (7 Vo l ts at 125°C ), Su r g e Vo l tage 11. 5 at 85°C
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +12C M (1.0) P (0.1) R (0.01)
T AT 226J 02511 22 5 1 6. 6 3. 98 1 2 825 -20 +10. 5 +12 0086 0306 0526
T AT 506M 02512 50 20 2 11 2. 92 1 2 1130 -28 +13 +15 0087 0307 0527
T AT 5 06K 0 2512 50 10 2 11 2. 92 1 2 1130 -28 +13 +15 0088 0308 0528
T AT 506J 02512 50 5 2 11 2. 92 1 2 1130 -28 +13 +15 0089 0309 0529
T AT 107M 02512 1 00 20 2 15 1. 99 1 10 1435 -28 +13 +15 00 90 03 10 0530
T AT 1 07K 0 2512 100 10 2 15 1.99 1 10 1435 -28 +13 +15 00 91 03 11 0 531
T AT 107J 02512 100 5 2 15 1. 99 1 10 1435 -28 +13 +15 00 92 03 12 0532
T AT 127M 02513 1 20 20 3 21 2. 32 2 6 1450 - 32 +13 +15 0093 0313 0533
T AT 1 27K 0 2513 120 10 3 21 2.32 2 6 1450 -32 +13 +15 0094 0314 0534
T AT 127J 02513 120 5 3 21 2. 32 2 6 1450 - 32 +13 +15 0095 0315 0535
T AT 187M 02513 180 20 3 26 1. 92 2 18 1525 -48 +13 +15 0096 0316 0536
T AT 1 87K 0 2513 180 10 3 26 1.92 2 18 1525 -48 +13 +15 00 97 03 17 0 537
T AT 187J 02513 180 5 3 26 1. 92 2 18 1525 -48 +13 +15 00 98 03 18 0538
T AT 357M 02514 3 50 20 4 35 1. 33 7 28 1970 -70 +25 +25 00 99 03 19 0539
T AT 3 57K 0 2514 350 10 4 35 1.33 7 28 1970 -70 +25 +25 01 00 03 20 0 540
T AT 805M 03011 8 20 1 4 6.64 1 2 640 -16 +8 +12 0101 0321 0541
T AT 8 05K 0 3011 8 10 1 4 6.64 1 2 640 -16 +8 +12 0102 0322 0542
T AT 805J 03011 8 5 1 4 6. 64 1 2 640 -16 +8 +12 0103 0323 0 543
T AT 156M 03011 15 20 1 5 4. 42 1 2 780 -20 +10.5 +12 0104 0324 0544
T AT 1 56K 0 3011 15 10 1 5 4.42 1 2 780 -20 +10. 5 +12 01 05 03 25 0 545
T AT 156J 03011 15 5 1 5 4. 42 1 2 780 -20 +10. 5 +12 01 06 0326 0546
T AT 406M 03012 40 20 2 10 3. 32 1 5 1120 -24 +10. 5 +12 0107 0327 0547
T AT 4 06K 0 3012 40 10 2 10 3. 32 1 5 1120 -24 +10. 5 +12 01 08 03 28 0 548
T AT 406J 03012 40 5 2 10 3. 32 1 5 1120 -24 +10. 5 +12 0109 0329 0549
T AT 686M 03012 68 20 2 13 2. 54 1 8 1285 -24 +13 +15 0110 0330 0550
T AT 6 86K 0 3012 68 10 2 13 2. 54 1 8 1285 -24 +13 +15 0111 0331 0551
T AT 686J 03012 68 5 2 13 2. 54 1 8 1285 -24 +13 +15 0112 0332 0552
T AT 107M 03013 1 00 20 3 17 2. 26 2 12 1450 -28 +10. 5 +12 01 13 0333 0553
T AT 1 07K 0 3013 100 10 3 17 2.26 2 12 1450 -28 +10. 5 +12 0114 0334 0554
T AT 107J 03013 100 5 3 17 2. 26 2 12 1450 -28 +10. 5 +12 01 15 0335 0556
T AT 157M 03013 1 50 20 3 23 2. 03 2 18 1525 -48 +13 +15 01 16 03 36 0556
T AT 1 57K 0 3013 150 10 3 23 2.03 2 18 1525 -48 +13 +15 01 17 03 37 0 557
T AT 157J 03013 150 5 3 23 2. 03 2 18 1525 -48 +13 +15 01 18 03 38 0558
T AT 307M 03014 3 00 20 4 31 1. 37 8 32 1950 -60 +25 +25 01 19 03 39 0558
T AT 3 07K 0 3014 300 10 4 31 1.37 8 32 1950 -60 +25 +25 01 20 03 40 0 559
T AT 505M 05011 5 20 1 3 7. 96 1 2 580 -16 +5 +6 0121 03 41 0561
T AT 5 05K 0 5011 5 10 1 3 7.96 1 2 580 -16 +5 +6 0122 03 42 0 562
T AT 505J 05011 5 5 1 3 7.96 1 2 580 -16 +5 +6 0123 03 43 0563
T AT 106M 05011 10 20 1 4 5. 31 1 2 715 -24 +8 +9 0124 0344 0564
T AT 1 06K 0 5011 10 10 1 4 5.31 1 2 715 -24 +8 +9 0125 03 45 0 565
T AT 106J 05011 10 5 1 4 5.31 1 2 715 -24 +8 +9 0126 03 46 0566
T AT 256M 05012 25 20 2 8 4. 25 1 5 1005 -20 +10. 5 +12 0127 0347 0567
T AT 2 56K 0 5012 25 10 2 8 4.25 1 5 1005 -20 +10. 5 +12 01 28 0348 0 568
T AT 256J 05012 25 5 2 8 4.25 1 5 10 05 -20 +10. 5 +12 0129 0349 0569
T AT 476M 05012 47 20 2 11 3. 11 1 9 1155 - 28 +13 +15 0130 0350 0570
CDE
Comm ercial
Part Num be r
Cap
F)
Cap
Tol
(±)
Case
Code
Maximum %
Capacitance change
from Room
Tem perature
Part Number MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
Max
DF %
Max ESR
@+25ºC
(ȍ)
Maximum DC
Leakage
A)
Max
Ripple
@ +85°C
40kHz
(mA)
25 Vo l ts M axi mu m at 85°C (15 Vo l ts at 125°C ), Su r g e Vo l t ag e 28. 8 at 85°C
30 Vo l ts M axi mu m at 85°C (20 Vo l ts at 125°C ), Su r g e Vo l t ag e 34. 5 at 85°C
50 Vo l ts M axi mu m at 85°C (30 Vo l ts at 125°C ), Su r g e Vo l t ag e 57. 5 at 85°C
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
TAT(CLR79)
+25°C
+85 °C
&
+125°C -55°C +85°C +125°C M (1. 0) P (0. 1) R (0. 01)
T AT 4 76K 05012 47 10 2 11 3. 11 1 9 1155 -28 +13 +15 01 31 03 51 0 571
T AT 476J 05012 47 5 2 11 3. 11 1 9 1155 -28 +13 +15 0132 0352 0572
T AT 606M 05013 60 20 3 12 2. 65 2 12 1335 -16 +10. 5 +12 0133 0353 0573
T AT 6 06K 05013 60 10 3 12 2. 65 2 12 1335 -16 +10. 5 +12 0134 0354 0574
T AT 606J 05013 60 5 3 12 2. 65 2 12 1335 -16 +10. 5 +12 0135 0355 0575
T AT 826M 05013 82 20 3 15 2. 43 2 16 1400 -32 +13 +15 0136 0356 0576
T AT 8 26K 05013 82 10 3 15 2. 43 2 16 1400 -32 +13 +15 0137 0357 0577
T AT 826J 05013 82 5 3 15 2. 43 2 16 1400 -32 +13 +15 01 38 0358 0578
T AT 167M 05014 160 20 4 17 1. 41 8 32 1900 -50 +25 +25 0139 0359 0579
T AT 1 67K 05014 160 10 4 17 1. 41 8 32 19 00 -50 +25 +25 0140 0360 0580
T AT 405M 06011 4 20 1 2 .8 9. 29 1 2 525 -16 +5 +6 0141 0361 0581
T AT 4 05K 06011 4 10 1 2 . 8 9. 29 1 2 525 -16 +5 +6 0142 0362 0 582
T AT 405J 06011 4 5 1 2 .8 9. 29 1 2 525 -16 +5 +6 0143 03 63 0583
T AT 825M 06011 8. 2 20 1 4 6. 47 1 2 625 -24 +8 +9 0144 0364 0 584
T AT 8 25K 06011 8. 2 10 1 4 6. 47 1 2 625 -24 +8 +9 01 45 03 65 0585
T AT 825J 06011 8. 2 5 1 4 6. 47 1 2 625 -24 +8 +9 0146 0366 0586
T AT 206M 06012 20 20 2 7 4. 64 1 5 930 -16 +10.5 +12 0147 0367 0587
T AT 2 06K 06012 20 10 2 7 4.64 1 5 930 -16 +10. 5 +12 01 48 03 68 0 588
T AT 206J 06012 20 5 2 7 4. 64 1 5 930 -16 +10.5 +12 0149 0369 0589
T AT 396M 06012 39 20 2 10 3. 4 1 9 1110 -28 +10. 5 +12 0150 0370 0590
T AT 3 96K 06012 39 10 2 10 3. 4 1 9 1110 -28 +10. 5 +12 01 51 03 71 0591
T AT 396J 06012 39 5 2 10 3. 4 1 9 1110 -28 +10. 5 +12 0152 0372 0592
T AT 506M 06013 50 20 3 10 2. 65 2 12 1330 16 +10. 5 +12 0153 0373 0593
T AT 5 06K 06013 50 10 3 10 2. 65 2 12 13 30 16 +10. 5 +12 01 54 03 74 0 594
T AT 506J 06013 50 5 3 10 2. 65 2 12 1330 16 +10. 5 +12 0155 0375 0595
T AT 686M 06013 68 20 3 13 2. 54 2 16 1365 -32 +10.5 +12 0156 0376 0596
T AT 6 86K 06013 68 10 3 13 2. 54 2 16 1365 -32 +10. 5 +12 0157 0377 0597
T AT 686J 06013 68 5 3 13 2. 54 2 16 1365 -32 +10. 5 +12 01 58 0378 0598
T AT 147M 06014 140 20 4 16 1. 52 8 32 18 50 -40 +20 +20 0159 0379 0599
T AT 1 47K 06014 140 10 4 16 1. 52 8 32 1850 -40 +20 +20 01 60 03 80 0 600
T AT 355M 07511 3. 5 20 1 2 .5 9. 48 1 2 525 -16 +5 +6 0161 0381 0601
T AT 3 55K 07511 3. 5 10 1 2. 5 9. 48 1 2 525 -16 +5 +6 0162 0382 0602
T AT 355J 07511 3. 5 5 1 2 .5 9. 48 1 2 525 -16 +5 +6 0163 0383 0603
T AT 685M 07511 6. 8 20 1 3 .5 6. 83 1 2 610 -20 8 +9 0164 0384 0604
T AT 6 85K 07511 6. 8 10 1 3. 5 6. 83 1 2 610 -20 8 +9 0165 0385 0605
T AT 685J 07511 6. 8 5 1 3 .5 6. 83 1 2 610 -20 8 +9 01 66 0386 0606
T AT 156M 07512 15 20 2 6 5. 31 1 5 890 -16 +8 +9 0167 0387 0607
T AT 1 56K 07512 15 10 2 6 5.31 1 5 890 -16 +8 +9 01 68 0388 0 608
T AT 156J 07512 15 5 2 6 5. 31 1 5 890 -16 +8 +9 0169 0389 0609
T AT 336M 07512 33 20 2 10 4. 02 1 10 1000 -24 +10.5 +15 0170 0390 0610
T AT 3 36K 07512 33 10 2 10 4. 02 1 10 1000 -24 +10. 5 +15 0171 0391 0611
T AT 3 36J 07512 33 5 2 10 4. 02 1 10 10 00 -24 +10. 5 +15 01 72 03 92 0612
T AT 406M 07513 40 20 3 9 2. 99 2 12 1250 -16 +10.5 +12 0173 0393 0613
T AT 4 06K 07513 40 10 3 9 2.99 2 12 1250 -16 +10. 5 +12 01 74 03 94 0 614
T AT 406J 07513 40 5 3 9 2. 99 2 12 1250 -16 +10. 5 +12 0175 0395 0615
T AT 566M 07513 56 20 3 11 2. 61 2 17 1335 -28 +10.5 +12 0176 0396 0616
75 Vo l ts M axi mu m at 85°C (5 0 Vo lts at 125 °C ), Su r g e Vo l tage 86. 2 at 85°C
CDE Com m ercial
Par t N u mb er Cap
F)
Cap
Tol
(±)
Case
Code Max
DF %
Max ESR
@+25ºC
(Ȏ)
60 Vo l ts M axi mu m at 85°C (4 0 Vo lts at 125 °C ), Su r g e Vo l tage 69 at 85°C
Maxim um DC
L eakag e (µA) Max
Ri pp le @
+85°C
40kH z
(mA)
50 Vo l ts M axi mu m at 85°C (3 0 Vo lts at 125 °C ), Su r g e Vo l tage 57. 5 at 85°C
Maxim um % Capacitance
ch an g e fr om R o o m
Tem perature
Change from
Part Num ber MIL-C-M39006/22
F ai l u re R ate Level/%1000
Hours
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AT 566K 07513 56 10 3 11 2.61 2 17 1335 -28 10.5 +15 0177 0397 0617
T AT 566J 07513 56 5 3 11 2.61 2 17 1335 -28 1 0.5 +15 0 178 0398 0618
T AT 117M 07514 110 20 4 12 1. 45 9 36 1850 -35 +20 +2 0 0179 0399 0619
T AT 117K 07514 110 10 4 12 1.45 9 36 1850 -35 +20 +20 0180 0400 0620
T AT 255M 10011 2. 5 20 1 2 10. 62 1 2 505 -16 +7 +8 0 181 0401 0621
T AT 255K 10011 2. 5 10 1 2 10. 62 1 2 505 -16 +7 +8 0 182 0402 0622
T AT 255J 10011 2.5 5 1 2 10.62 1 2 505 -16 +7 +8 0183 0403 0623
T AT 475M 10011 4. 7 20 1 3 8. 47 1 2 565 -16 +7 +8 0 184 0404 0624
T AT 475K 10011 4. 7 10 1 3 8. 47 1 2 565 -16 +7 +8 0 185 0405 0625
T AT 475J 10011 4.7 5 1 3 8. 47 1 2 565 -16 +7 +8 0 186 0406 0626
T AT 116M 10012 11 20 2 5 6. 03 1 4 835 -16 +8 +8 0 187 0407 0627
T AT 116K 10012 11 10 2 5 6. 03 1 4 835 -16 +8 +8 0 188 0408 0628
T AT 116J 10012 11 5 2 5 6.03 1 4 835 -16 +8 +8 0 189 0409 0629
T AT 226M 10012 22 20 2 7. 5 4. 52 1 9 965 -16 +8 +8 0 190 0410 0630
T AT 226K 10012 22 10 2 7 .5 4.52 1 9 965 -16 +8 +8 0 191 0411 0631
T AT 226J 10012 22 5 2 7. 5 4. 52 1 9 96 5 -16 +8 +8 0 192 0412 0632
T AT 306M 10013 30 20 3 7 3. 10 2 12 1240 -16 +8 +8 0 193 0413 0633
T AT 306K 10013 30 10 3 7 3. 10 2 12 1240 -16 +8 +8 0 194 0414 0634
T AT 306J 10013 30 5 3 7 3.10 2 12 1240 -16 +8 +8 0 195 0415 0635
T AT 436M 10013 43 20 3 8. 5 2. 62 2 17 1335 -20 +8 +8 0 196 0416 0636
T AT 436K 10013 43 10 3 8 .5 2.62 2 17 1335 -20 +8 +8 0 197 0417 0637
T AT 436J 10013 43 5 3 8. 5 2. 62 2 17 1335 -20 +8 +8 0 198 0418 0638
T AT 866M 10014 86 20 4 10 1. 54 9 36 1800 -25 +15 +1 5 0199 0419 0639
T AT 866K 10014 86 10 4 10 1. 54 9 36 1800 -25 +15 +15 0 200 0420 0640
T AT 175M 12511 1. 7 20 1 2 15. 61 1 2 415 -16 +7 +8 0 201 0421 0641
T AT 175K 12511 1. 7 10 1 2 15. 61 1 2 415 -16 +7 +8 0 202 0422 0642
T AT 175J 12511 1.7 5 1 2 15.61 1 2 415 -16 +7 +8 0203 0423 0643
T AT 365M 12511 3. 6 20 1 2.7 9. 95 1 2 520 -16 +7 +8 0 204 0424 0644
T AT 365K 12511 3. 6 10 1 2. 7 9. 95 1 2 52 0 -16 +7 +8 0205 0425 0645
T AT 365J 12511 3.6 5 1 2 . 7 9. 95 1 2 52 0 -16 +7 +8 0206 0426 0646
T AT 905M 12512 9 20 2 5 7. 37 1 5 755 -16 +7 +8 0 207 0427 0647
T AT 905K 12512 9 10 2 5 7. 37 1 5 755 -16 +7 +8 0 208 0428 0648
T AT 905J 12512 9 10 2 5 7. 37 1 5 755 -16 +7 +8 0 209 0429 0649
T AT 146M 12512 14 20 2 6 5. 69 1 7 860 -16 +7 +8 0 210 0430 0650
T AT 146K 12512 14 10 2 6 5. 69 1 7 860 -16 +7 +8 0 211 0431 0651
T AT 146J 12512 14 5 2 6 5.69 1 7 860 -16 +7 +8 0 212 0432 0652
T AT 186M 12513 18 20 3 5 3. 69 2 9 1130 -16 +7 +8 0 213 0433 0653
T AT 186K 12513 18 10 3 5 3. 69 2 9 1130 -16 +7 +8 0214 0434 0654
T AT 186J 12513 18 5 3 5 3.69 2 9 1130 -16 +7 +8 0215 0435 0655
T AT 256M 12513 25 20 3 6 3. 18 2 13 1200 -16 +7 +8 0 216 0436 0656
T AT 256K 12513 25 10 3 6 3. 18 2 13 1200 -16 +7 +8 0 217 0437 0657
T AT 256J 12513 25 5 3 6 3.18 2 13 1200 -16 +7 +8 0 218 0438 0658
T AT 566M 12514 56 20 4 6. 5 1. 54 10 40 1800 -25 +15 +15 0 219 0439 0659
T AT 566K 12514 56 10 4 6 .5 1.54 10 40 1800 -25 +15 +15 0 220 0440 0660
Cap
F)
Cap
Tol
(±)
Case
Code
Maximum %
Capacitance change
from Room
Tem perature
Part Num ber MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
100 Vo l ts M aximum at 85°C (65Vo l ts at 125°C ), Sur g e Vo l tag e 115 at 85°C
125 Vo l ts M aximu m at 85°C (85 Vo lts at 125°C ), Su r g e Vo l tage 144 at 85°C
75 Vo l ts M aximum at 85°C (50 Vo l ts at 125°C ), Su r g e Vo ltag e 86. 2 at 85°C
Max
DF %
Max ESR
@+25ºC
(ȍ)
Maximum DC
Leakage
A)
Max
Ripple
@ +85°C
40kHz
(mA)
CDE
Comm ercial
Part Num be r
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
TAX (CLR81)
+25°C
+85°C
& +125°C -5C +8C +125°C M (1.0) P (0.1) R (0.01)
T AX227 M 00611 220 20 1 5 0 3. 02 2 9 1000 -64 +13 +16 0 001 00 89 0177
T AX227 K 00611 220 10 1 50 3 . 02 2 9 1000 -6 4 +13 +16 0002 0090 017 8
T AX827M 00612 8 20 20 2 155 2. 5 1 3 14 1500 -88 +16 +20 0003 00 91 017 9
T AX827 K 00612 820 10 2 155 2 . 51 3 1 4 1500 -88 +16 +20 0004 00 92 0180
T AX158M 00613 1500 20 3 172 1 . 52 5 20 19 00 -90 +20 +25 0005 00 93 018 1
T AX158K 00 613 1500 10 3 172 1 . 52 5 2 0 1900 -90 +20 +25 0 006 00 94 0182
T AX228M 00614 2200 20 4 170 1 . 03 6 24 23 00 -90 +25 +30 0007 00 95 018 3
T AX228K 00 614 2200 10 4 170 1 . 03 6 2 4 2300 -90 +25 +30 0 008 00 96 0184
T AX187 M 00811 180 20 1 4 1 3. 02 2 9 1000 -60 +13 +16 0 009 00 97 0185
T AX187 K 00811 180 10 1 41 3 . 02 2 9 1000 -6 0 +13 +16 0010 0098 018 6
T AX687M 00812 6 80 20 2 130 2. 5 4 3 14 1500 -83 +16 +20 0011 00 99 018 7
T AX687 K 00812 680 10 2 130 2 . 54 3 1 4 1500 -83 +16 +20 0012 01 00 0188
T AX158M 00813 1500 20 3 170 1 . 50 5 20 19 00 -90 +20 +25 0013 01 01 018 9
T AX158K 00 813 1500 10 3 170 1 . 50 5 2 0 1900 -90 +20 +25 0 014 01 02 0190
T AX188M 00814 1800 20 4 138 1 . 02 7 25 23 00 -90 +25 +30 0015 01 03 019 1
T AX188K 00 814 1800 10 4 138 1 . 02 7 2 5 2300 -90 +25 +30 0 016 01 04 0192
TAX157M 01011 150 20 1 34 3.01 2 9 900 -55 +13 +16 0017 0105 0193
T AX157 K 01011 150 10 1 3 4 3. 01 2 9 900 -5 5 +13 +16 0 018 0106 0194
T AX567M 01012 5 60 20 2 106 2. 5 1 3 16 1450 -77 +16 +20 0019 01 07 019 5
T AX567 K 01012 560 10 2 106 2 . 51 3 1 6 1450 -77 +16 +20 0020 01 08 0196
T AX128M 01013 1200 20 3 137 1 . 51 5 20 18 50 -88 +20 +25 0021 01 09 019 7
T AX128K 01 013 1200 10 3 137 1 . 51 5 2 0 1850 -88 +20 +25 0 022 01 10 0198
T AX158M 01014 1500 20 4 114 1 . 01 7 25 23 00 -88 +25 +30 0023 01 11 019 9
T AX158K 01 014 1500 10 4 114 1 . 01 7 2 5 2300 -88 +25 +30 0 024 01 12 0200
TAX107M 01511 100 20 1 30 3.98 2 9 900 -44 +13 +16 0025 0113 0201
T AX107 K 01511 100 10 1 3 0 3. 98 2 9 900 -4 4 +13 +16 0 026 0114 0202
TAX397M 01512 390 20 2 74 2.52 3 16 1450 -66 +16 +20 0027 0115 0203
T AX397 K 01512 390 10 2 74 2 . 52 3 1 6 1450 -6 6 +16 +20 0028 0116 020 4
T AX827M 01513 8 20 20 3 111 1. 8 0 6 24 1800 -77 +20 +25 0029 01 17 020 5
T AX827 K 01513 820 10 3 111 1 . 80 6 2 4 1800 -77 +20 +25 0030 01 18 0206
T AX108 M 01514 10 00 20 4 9 2 1. 22 8 3 2 2300 -77 +25 +30 0031 01 19 020 7
T AX108 K 01514 1000 10 4 92 1 . 22 8 3 2 2300 -77 +25 +30 0032 01 20 0208
T AX686 M 02511 68 20 1 22 4 . 29 2 9 8 50 -40 +12 +15 0 033 0121 0209
T AX686 K 02511 68 10 1 2 2 4. 29 2 9 850 -4 0 +12 +15 0 034 0122 0210
TAX277M 02512 270 20 2 55 2.70 3 16 1400 -62 +13 +16 0035 0123 0211
T AX277 K 02512 270 10 2 55 2 . 70 3 1 6 1400 -6 2 +13 +16 0036 0124 021 2
TAX567M 02513 560 20 3 76 1.80 7 28 1750 -72 +20 +25 0037 0125 0213
T AX567 K 02513 560 10 3 76 1 . 80 7 2 8 1750 -7 2 +20 +25 0038 0126 021 4
TAX687M 02514 680 20 4 63 1.23 8 32 2100 -72 +25 +30 0039 0127 0215
T AX687 K 02514 680 10 4 63 1 . 23 8 3 2 2100 -7 2 +25 +30 0040 0128 021 6
T AX566 M 03011 56 20 1 22 5 . 21 2 9 8 00 -38 +12 +15 0 041 0129 0217
T AX566 K 03011 56 10 1 2 2 5. 21 2 9 800 -3 8 +12 +15 0 042 0130 0218
TAX227M 03012 220 20 2 42 2.53 3 16 1200 -60 +13 +16 0043 0131 0219
T AX227 K 03012 220 10 2 42 2 . 53 3 1 6 1200 -6 0 +13 +16 0044 0132 022 0
Maximum %
Capacitance Change
from Room
Temperature
Part Number MIL-C-
M39006/25 Failure Rate
Level/%1000 Hours
Cap
Tol
)
Case
Code
Maximum DC
Leakage A)
Max
Ripple
@ +85°C
40kHz
(mA)
6 Volts Maxim um at 85°C(4 Volts at 125°C), Surge Voltage 6.9 at 85°C
Max
DF %
Max ESR
@+25ºC
(ȍ)
30 Volts Maximum at 85°C(20 Volts at 125°C), Surge Voltage 34.5 at 85°C
10 Volts Maxim um at 85°C(7 Volts at 125°C), Surge Voltage 11.5 at 85°C
15 Volts Maximum at 85°C(10 Volts at 125°C), Surge Voltage 17.2 at 85°C
25 Volts Maximum at 85°C(15 Volts at 125°C), Surge Voltage 28.8 at 85°C
8 Volts Maxim um at 85°C(5 Volts at 125°C), Surge Voltage 9.2 at 85°C
CDE Com m ercial
Part Num ber
Cap
F)
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
TAX (CLR81)
+25°C
+85°C
&
+125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AX477M 03013 470 20 3 64 1. 81 8 32 1500 -65 +20 +25 0045 0133 0221
T AX477K 03013 470 10 3 64 1. 81 8 32 1500 -65 +20 +25 0046 0134 0222
T AX567M 03014 560 20 4 55 1. 30 9 36 2000 -65 +25 +30 0047 0135 0223
T AX567K 03014 560 10 4 55 1. 30 9 36 2000 -65 +25 +30 0048 0136 0224
T AX336M 05011 33 20 1 12. 3 4. 95 2 9 700 -29 +10 +12 0049 0137 0225
T AX336K 05011 33 10 1 12. 3 4. 95 2 9 700 -29 +10 +12 0050 0138 0226
T AX127M 05012 120 20 2 22. 5 2. 49 4 24 1200 -42 +12 +15 0051 0139 0227
T AX127K 05012 120 10 2 22. 5 2. 49 4 24 1200 -42 +12 +15 0052 0140 0228
T AX277M 05013 270 20 3 37 1. 82 8 32 1450 -46 +20 +25 0053 0141 0229
T AX277K 05013 270 10 3 37 1. 82 8 32 1450 -46 +20 +25 0054 0142 0230
T AX337M 05014 330 20 4 38 1. 53 9 36 1900 -46 +25 +30 0055 0143 0231
T AX337K 05014 330 10 4 38 1. 53 9 36 1900 -46 +25 +30 0056 0144 0232
T AX276M 06011 27 20 1 10. 2 5. 01 3 12 700 -24 +10 +12 0057 0145 0233
T AX276K 06011 27 10 1 10. 2 5. 01 3 12 700 -24 +10 +12 0058 0146 0234
T AX107M 06012 100 20 2 19 2. 52 4 20 1100 -36 +12 +15 0059 0147 0235
T AX107K 06012 100 10 2 19 2. 52 4 20 1100 -36 +12 +15 0060 0148 0236
T AX227M 06013 220 20 3 30 1. 81 8 32 1400 -40 +16 +20 0061 0149 0237
T AX227K 06013 220 10 3 30 1. 81 8 32 1400 -40 +16 +20 0062 0150 0238
T AX277M 06014 270 20 4 27 1. 33 9 36 1850 -45 +20 +25 0063 0151 0239
T AX277K 06014 270 10 4 27 1. 33 9 36 1850 -45 +20 +25 0064 0152 0240
T AX226M 07511 22 20 1 8. 5 5. 13 3 12 600 -19 +10 +12 0065 0153 0241
T AX226K 07511 22 10 1 8. 5 5. 13 3 12 600 -19 +10 +12 0066 0154 0242
T AX826M 07512 82 20 2 15. 2 2. 46 4 24 1000 -30 +12 +15 0067 0155 0243
T AX826K 07512 82 10 2 15. 2 2. 46 4 24 1000 -30 +12 +15 0068 0156 0244
T AX187M 07513 180 20 3 24. 4 1. 80 9 36 1300 -35 +16 +20 0069 0157 0245
T AX187K 07513 180 10 3 24. 4 1. 80 9 36 1300 -35 +16 +20 0070 0158 0246
T AX227M 07514 220 20 4 37 2. 23 10 40 1800 -40 +20 +25 0071 0159 0247
T AX227K 07514 220 10 4 37 2. 23 10 40 1800 -40 +20 +25 0072 0160 0248
T AX106M10011 10 20 1 4.5 5. 97 3 12 800 -17 +10 +12 0073 0161 0249
T AX106K10011 10 10 1 4.5 5. 97 3 12 800 -17 +10 +12 0074 0162 0250
T AX396M10012 39 20 2 10. 4 3. 54 5 24 1300 -20 +12 +15 0075 0163 0251
T AX396K10012 39 10 2 10. 4 3. 54 5 24 1300 -20 +12 +15 0076 0164 0252
T AX686M10013 68 20 3 11. 3 2. 21 10 40 1600 -30 +14 +16 0077 0165 0253
T AX686K10013 68 10 3 11. 3 2. 21 10 40 1600 -30 +14 +16 0078 0166 0254
T AX127M10014 120 20 4 25 2. 76 12 48 2000 -35 +15 +17 0079 0167 0255
T AX127K10014 120 10 4 25 2. 76 12 48 2000 -35 +15 +17 0080 0168 0256
T AX685M12511 6.8 20 1 6 11. 71 3 12 700 -14 +10 +12 0081 0169 0257
T AX685K12511 6.8 10 1 6 11. 71 3 12 700 -14 +10 +12 0082 0170 0258
T AX276M12512 27 20 2 7.2 3. 54 5 24 1200 -18 +12 +15 0083 0171 0259
T AX276K12512 27 10 2 7.2 3. 54 5 24 1200 -18 +12 +15 0084 0172 0260
T AX476M12513 47 20 3 7.9 2. 23 10 40 1500 -26 +14 +16 0085 0173 0261
T AX476K12513 47 10 3 7.9 2. 23 10 40 1500 -26 +14 +16 0086 0174 0262
T AX826M12514 82 20 4 17.4 2. 82 12 48 1900 -30 +15 +17 0087 0175 0263
T AX826K12514 82 10 4 17.4 2. 82 12 48 1900 -30 +15 +17 0088 0176 0264
100 Volts M axim um at 85°C(65Volts at 125°C), Surge Voltage 115 at 85°C
125 Volts M axim um at 85°C(85 Volts at 125°C), Surge Voltage 144 at 85°C
Cap
Tol
)
Case
Code
60 Volts M axim um at 85°C(40 Volts at 125°C), Surge Voltage 69 at 85°C
75 Volts M axim um at 85°C(50 Volts at 125°C), Surge Voltage 86.2 at 85°C
Maximum %
Capacitance Change
from Room
Tem perature
Part Num ber MIL-C-
M39006/25 Failure Rate
Level/%1000 HoursCDE Commercial
Part Num ber
Cap
F)
30 Volts M axim um at 85°C(20 Volts at 125°C), Surge Voltage 34.5 at 85°C
50 Volts M axim um at 85°C(30 Volts at 125°C), Surge Voltage 57.5 at 85°C
Maximum DC
Leakage
A)
Max
Ripp le
@ +85°C
40kHz
(mA)
Max
DF %
Max ESR
@+25ºC
(ȍ)
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
Performance Testing
Seal: MIL-STD-202 - Method 112
xConditions A, or D, and C
Specified Pulse Shock Test: MIL-STD-202 - Method 213 includes the following:
xCondition D (500g’s)
xMount the capacitor by its body securely on a fixture taking special care not to squeeze the leads.
xWhile testing apply DC rated voltage. Record whether open or short circuiting, arcing, or intermittent contact
occurs. Use detecting equipment capable of detecting a disruption at a period of time up to 0.5 ms.
xAt the conclusion of testing examine the capacitors for evidence of arcing, breakdown, or mechanical damage.
Thermal Shock: MIL-STD-202 – Method 107, Condition A (with step 3 at +125°C).
In accordance with MIL-PRF-39006, the following shall apply:.
xTake measurements before and after cycling.
xTake measurements at 15-minute intervals at 300 cycles (Group C).
xTake final measurements at room temperature.
High Frequency Vibration: MIL-STD-202 - Method 204 includes the following:
xCondition H (80g’s)
xMount the capacitor body securely on a fixture with the leads firmly supported.
xApply DC rated voltage while measuring specific electrical load conditions.
xThe vibration duration is 4 hours in two perpendicular directions for an overall time of 8 hours.
xTake measurements during the last cycle vibration to determine open, short-circuiting or intermittent operation.
Use detecting equipment capable of detecting a disruption at a period of time of 0.5ms or greater. Assess the
units for mechanical damage and test for these electrical requirements:.
oDC Leakage — Not greater than 1.25 initial limit
oCapacitance — No change greater than ±5% of the initial limit
oDF — Not greater than 1.15 of initial limit
Random Vibration: MIL-STD-202 – Method 214
xTest condition II-K (51 g’s)
Salt atmosphere: MIL-STD-202 – Method 101
xCondition B 48 hours
Solderability: MIL-STD-202 – Method 208
xTest both terminations with the insertion depth of flux and solder within .062" of welded seam.
Lead Terminal Strength:
xPull Test: MIL-STD-202 – Method 211, condition A
xWire-lead bend: Per MIL-PRF-39006.
xDuring the test securely clamp the capacitor body. Apply a force of 3 pounds or 1.4 kg for 30 seconds.
Moisture resistance: MIL-STD-202- Method 106, which includes the following:
xMount the capacitor body securely on a fixture taking special care not to squeeze the leads.
xApply 6 volts, polarizing and load voltage.
xAt the time of the capacitors complete their final cycle remove them from the humidity chamber and measure
per MIL-PRF-30006 for DC Leakage, dissipation factor, and capacitance.
oDCL: 125% (Maximum) of +25°C value of standard ratings table
o'Cap: Within ±8% of initial measurement
oDF: 115% (maximum) of initial requirement
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
Dielectric withstanding voltage
xMIL-STD-202 – Method 301, 2000 VDC minimum
Insulation Resistance (IR): MIL-STD-202 – Method 302, condition B
x100 Megohms minimum
Low temperature storage: MIL-STD-810 – Method 502
xDCL and DF: Initial requirements
x'Cap within r5% of initial measurement
Low and high temperature stability: –55qq
qq
qC to +125qq
qq
qC.
Measure capacitors for thermal stability by testing at these temperatures in this order: +25qC, –55qC, +25qC, +85qC,
+125qC, and +25qC. Measure Capacitance and DF at the temperatures listed below with the exception of the DCL, which
is not measured at –55qC.
xStep 1 (+25qC)
DCL and DF: See standard ratings table
'Cap: Within tolerance of standard ratings table
xStep 2 (–55qC)
Impedance and 'Cap: See standard ratings table
xStep 3 (+25qC)
DCL and DF: See standard ratings table
'Cap: Within r5% of step one value
xStep 4 (+85qC)
'Cap, DCL, and DF: See standard ratings table
xStep 5 (+125qC)
'Cap, DCL, and DF: See standard ratings table
xStep 6 (+25qC)
DCL and DF: See standard ratings table
'Cap: Within r5% of step one value
Resistance to Soldering Heat: MIL-STD-202- Method 210, condition C
xDCL and DF: See standard ratings table
x'Cap: Within r5% of initial measurement
Life test at 85qq
qq
qC/125qq
q
q
qC, 2000 hours: MIL-STD-202 – Method 108
xDCL and DF: See standard ratings table
x'Cap: Within r10% of initial measurement
Cross Reference
Type Series MIL Type Kemet Sprague Tansitor Mallory Arcotronics
Typical ESR, C,V TAT M39006/22 T192 135D AQ/HAQ THT/TLX TH
Extended Range TAX M39006/25 T195 135D AR/HAR THT/TLX TH
Cornell Dubilier
These capacitor types are not exactly the same. Review the specifications before purchase to assure interchangeability
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor
-
et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com
Application Guide
120 Hz 1 kHz 10 kHz 40 kHz 100 kHz
d55° 85° 10 125° d55° 8 105° 125° d55° 85° 10 125° d55° 8 105° 125° d55° 85° 105° 125°
% OF + 85°
RATED
PEAK VOLTAGE
100% .60 .39 - - .72 .45 - - .88 .55 - - 1.0 .63 - - 1.1 .69 - -
90% .60 .46 - - .72 .55 - - .88 .67 - - 1.0 .77 - - 1.1 .85 - -
80% .60 .52 .35 - .72 .62 .42 .88 .76 .52 - 1.0 .87 .59 - 1.1 .96 .65 -
70% .60 .58 .36 - .72 .70 .52 .88 .85 .64 - 1.0 .97 .73 - 1.1 1.07 .80 -
66 2/3%
and below .60 .60 .37 .27 .72 .72 .55 .32 .88 .88 .68 .40 1.0 1.0 .77 .45 1.1 1.1 .85 .50
RIPPLE CURRENT RIPPLE VOLTAGE
The ripple current listed in the Ratings Table for each The peak of the applied AC ripple voltage plus the applied DC
capacitor rating is the maximum permissible rms ripple voltage must not exceed the DC voltage rating of the cap-
current at 40 kHz, 85°C and 2/3 of the 85°C peak voltage. acitor either forward or reverse.
The rms ripple rating at 85°C and 40 kHz is based on a Capacitors must be biased such that the negative peak
maximum internal temperature rise of 50°C. The maximum is not more negative than –3 volts and the positive peak
allowable internal temperature rise decreases linearly does not exceed the voltage rating of the capacitor.
from 50°C to 10°C at an ambient of 125°C.
The applied DC voltage should be of sufficient magnitude
RIPPLE CURRENT MULTIPLIERS to prevent polarity reversal in excess of 3 volts at 85°C
The rms ripple current capability is shown in the Standard and 2 volts at 125°C.
Ratings Table for each rating at 85°C ambient and at 40 kHz.
For operation at other temperatures and frequencies use CAUTIONS AGAINST MISAPPLICATION
the multipliers shown in the Ripple Current Multipliers Table. 1. Do not operate at temperatures above the maximum rated.
2. Do not exceed rated WVdc and Surge Voltage of the capacitor.
SHELF LIFE 3. Do not apply ripple voltage or ripple current in excess of
These capacitors have an expected shelf life of ten or specification limits.
more years when stored at room temperature. Cold
storage has no adverse effects on the capacitor. Violations of above can be hazardous and can cause capacitor
failure or equipment failure.
RIPPLE CURRENT MULTIPLIERS FOR FREQUENCY, TEMPERATURE, AND APPLIED PEAK VOLTAG
E
APPLIED RIPPLE CURRENT FREQUENCY
RIPPLE CURRENT MULTIPLIERS
OPERATING TEMPERAT URE °C
AMBIENT STILL
AIR
CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Types TAT and T Tantalum Capacitor -et
AX W
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 • www.cde.com