A Q-R SOLID STATE RELAY AQ-R
RELAYS
UL File No.: E43149
CSA File No.: LR49089M14
• Two types of terminal shape: Plug-in terminal and
Screw terminal
Plug-in terminal (output side): #250
(input side): #110
• Flat type of SSR realized by aluminium printed
circuit board
Plug-in terminal: height max. 15 mm .591 inch
Screw terminal: height max. 17 mm .669 inch
• High dielectric strength: 1500 V AC (between input
and output)
• Heat sink and DIN mounting rail are available as
accessories
TYPES
Plug-in terminal type
Type
Zero-cross
10 A
Zero-cross
15 A
Zero-cross
20 A
Load voltage
75 to 125 V AC
75 to 250 V AC
75 to 125 V AC
75 to 250 V AC
75 to 125 V AC
75 to 250 V AC
Input voltage
4 to 6 V DC AQR10A1-Z4/6VDC
10 to 18 V DC AQR10A1-Z10/18VDC
18 to 28 V DC AQR10A1-Z18/28VDC
4 to 6 V DC AQR10A2-Z4/6VDC
10 to 18 V DC AQR10A2-Z10/18VDC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
AQR10A2-Z18/28VDC
AQR15A1-Z4/6VDC
AQR15A1-Z10/18VDC
AQR15A1-Z18/28VDC
AQR15A2-Z4/6VDC
AQR15A2-Z10/18VDC
AQR15A2-Z18/28VDC
AQR20A1-Z4/6VDC
AQR20A1-Z10/18VDC
AQR20A1-Z18/28VDC
AQR20A2-Z4/6VDC
AQR20A2-Z10/18VDC
AQR20A2-Z18/28VDC
Part No. Screw-terminal type
Type
Zero-cross
10 A
Zero-cross
15 A
Zero-cross
20 A
Load voltage
75 to 125 V AC
75 to 250 V AC
75 to 125 V AC
75 to 250 V AC
75 to 125 V AC
75 to 250 V AC
Input voltage
4 to 6 V DC AQR10A1-S-Z4/6VDC
10 to 18 V DC AQR10A1-S-Z10/18VDC
18 to 28 V DC AQR10A1-S-Z18/28VDC
4 to 6 V DC AQR10A2-S-Z4/6VDC
10 to 18 V DC AQR10A2-S-Z10/18VDC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
4 to 6 V DC
10 to 18 V DC
18 to 28 V DC
AQR10A2-S-Z18/28VDC
AQR15A1-S-Z4/6VDC
AQR15A1-S-Z10/18VDC
AQR15A1-S-Z18/28VDC
AQR15A2-S-Z4/6VDC
AQR15A2-S-Z10/18VDC
AQR15A2-S-Z18/28VDC
AQR20A1-S-Z4/6VDC
AQR20A1-S-Z10/18VDC
AQR20A1-S-Z18/28VDC
AQR20A2-S-Z4/6VDC
AQR20A2-S-Z10/18VDC
AQR20A2-S-Z18/28VDC
Part No.
APPLICATIONS
• Photocopiers
• Air conditioners
• Vending machines
• Machine tools
ORDERING INFORMATION
Ex. AQR 10A 1 S Z 4/6VDC
Load current
10 A, 15 A,
20 A 1: 75 to 125 V AC
2: 75 to 250 V AC Nil: Plug-in terminal
S: Screw terminal Z: Zero-cross
Z: type 4/6, 10/18,
18/28 V DC
Load voltage Terminal shape Type Input voltage
SPECIFICATIONS
Ratings (at 20°C 68°F, Input ripple: 1% or less)
10 A type Part No. AQR10A1-Z
4/6VDC
AQR10A1-S-Z
4/6VDC AQR10A1-S-Z
10/18VDC AQR10A1-S-Z
18/28VDC AQR10A2-S-Z
4/6VDC AQR10A2-S-Z
10/18VDC AQR10A2-S-Z
18/28VDC
AQR10A1-Z
10/18VDC AQR10A1-Z
18/28VDC AQR10A2-Z
4/6VDC AQR10A2-Z
10/18VDC Remarks
AQR10A2-Z
18/28VDC
Items Input voltage
Max. load current 10 A See “DATA 1”
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency
Min. load current 100 mA
OFF-state dV/dt 100 V/µs
45 to 65 Hz
Input impedance
Drop-out voltage,
min.
Repetitive peak
voltage
Non-repetitive
surge current In one cycle at
60 Hz
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop at max.
carrying current
4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC
Approx. 0.26 kApprox. 0.86 kApprox. 1.36 k
1 V
400 V
100 A
1.6 V
600 V
2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Approx. 0.26 k10 to 18 V DC 18 to 28 V DC
Approx. 0.86 kApprox. 1.36 k
Input
side
Load
side
15 A type Part No. AQR15A1-Z
4/6VDC
AQR15A1-S-Z
4/6VDC AQR15A1-S-Z
10/18VDC AQR15A1-S-Z
18/28VDC AQR15A2-S-Z
4/6VDC AQR15A2-S-Z
10/18VDC AQR15A2-S-Z
18/28VDC
AQR15A1-Z
10/18VDC AQR15A1-Z
18/28VDC AQR15A2-Z
4/6VDC AQR15A2-Z
10/18VDC Remarks
AQR15A2-Z
18/28VDC
Items Input voltage
Max. load current 15 A See “DATA 1”
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency
Min. load current 100 mA
OFF-state dV/dt 100 V/µs
45 to 65 Hz
Input impedance
Drop-out voltage,
min.
Repetitive peak
voltage
Non-repetitive
surge current In one cycle at
60 Hz
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop at max.
carrying current
4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC
Approx. 0.26 kApprox. 0.86 kApprox. 1.36 k
1 V
400 V
150 A
1.6 V
600 V
2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Approx. 0.26 k10 to 18 V DC 18 to 28 V DC
Approx. 0.86 kApprox. 1.36 k
Input
side
Load
side
20 A type Part No. AQR20A1-Z
4/6VDC
AQR20A1-S-Z
4/6VDC AQR20A1-S-Z
10/18VDC AQR20A1-S-Z
18/28VDC AQR20A2-S-Z
4/6VDC AQR20A2-S-Z
10/18VDC AQR20A2-S-Z
18/28VDC
AQR20A1-Z
10/18VDC AQR20A1-Z
18/28VDC AQR20A2-Z
4/6VDC AQR20A2-Z
10/18VDC Remarks
AQR20A2-Z
18/28VDC
Items Input voltage
Max. load current 20 A See “DATA 1”
Load voltage 75 to 125 V AC 75 to 250 V AC
Frequency
Min. load current 100 mA
OFF-state dV/dt 100 V/µs
45 to 65 Hz
Input impedance
Drop-out voltage,
min.
Repetitive peak
voltage
Non-repetitive
surge current In one cycle at
60 Hz
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop at max.
carrying current
4 to 6 V DC 10 to 18 V DC 18 to 28 V DC 4 to 6 V DC
Approx. 0.26 kApprox. 0.86 kApprox. 1.36 k
1 V
400 V
200 A
1.6 V
600 V
2.5 mA (when 100 V AC applied) 5 mA (when 200 V AC applied) at 60 Hz
Approx. 0.26 k10 to 18 V DC 18 to 28 V DC
Approx. 0.86 kApprox. 1.36 k
Input
side
Load
side
Characteristics (at 20°C 68°F, Input ripple: 1% or less)
Item
Operate time, max. (1/2 cycle of voltage sine wave) + 1 ms
Release time, max. (1/2 cycle of voltage sine wave) + 1 ms
Insulation resistance, min., Initial 100 M between input, output and case by 500 V DC
Breakdown voltage Functional
Vibration resistance
Shock resistance
Destructive
Functional
Destructive
10 to 55 Hz at double amplitude of 2 mm
10 to 55 Hz at double amplitude of 2 mm
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
10 minutes for X, Y, Z axes
1 hour for X, Y, Z axes
4 time each for X, Y, Z axes
5 time each for X, Y, Z axes
Ambient temperature
Storage temperature
Operational method
–20°C to +80°C –4°F to +176°F
–25°C to +85°C –13°F to +185°F
Zero-cross (Turn-ON and Turn-OFF)
1,500 V AC between input, output and case For 1 min.
Type Zero-cross type Remarks
OPERATING PRINCIPLE
Internal circuit
circuit
Trigger circuit
Photo TRIAC
coupler
+
_
Input Input
terminal Output
terminal
R
C
Triac
Snubber circuit
circuit
cross
Zero-
Wave form of input and output (Resistive load)
Load voltage
Load current
Input signal ON
OFF
DIMENSIONS
Plug-in terminal
Screw terminal
mm inch
Mounting dimensions (Bottom view)
Schematic
2-4.3 dia. or M4
2-.169 dia
Conform to AMP plug-in terminal
# 110 series receptacle
Mounting hole
47.6±0.1
1.874±.004
Conform to AMP plug-in terminal
#250 series receptacle
9
.354
Max. 7.5
Max. .295 Max. 12.5
Max. .492
Max. 15
Max. .591
59
2.323
47.6
1.874
44.8
1.764
26
1.024
2-4.4 dia.
2-.173 dia.
Load power
source
1
2
4
3
Input power
source
+
_Load
Mounting dimensions (Bottom view)
Schematic
2-4.3 dia. or M4
2-.169 dia
Mounting hole
4-M4
screw terminal
47.6±0.1
1.874±.004
9
.354
7.5
.295 12.5
.492
Max. 17
Max. .669
59
2.323
47.6
1.874
45.0
1.772
44.8
1.764
26
1.024
2-4.4 dia.
2-.173 dia.
Load power
source
1
2
4
3
Input power
source
+
_Load
AQ-R SOLID STATE RELAY ACCESSORIES mm inch
AQP-HS-20A
Heat sink
AQP-DP
DIN rail mounting plate
AT8-DLA1
Mounting rail ATA4806
Fastening plate
General tolerance: ±0.5 ±.020
86
3.386
44
1.732
18.1
.713
M4
70
2.765
56
2.205
47.6
1.874
13.6
.535
M4
M4
General tolerance: ±0.5 ±.020
15
.591
5
.197 5
.197
10
.394
1,000
39.37
5.5
.217 35
1.378 1.5
.059
27
1.063
24
.945
15
.591
40-5.5×15 slot
40-.217×.591 slot
15
.591 10
.394 15
.591
7.5
.295
2.75R
.108R
12
.472
50
1.969
M4
10
.394
10
.394
ATA4806
UP
AQP-DP
AQP-HS-20A
ATA4806
AT8-DLA1
AQ-R
DATA
1. Load current vs. ambient temperature
10 A type
0
–30 0 20 40 60 80
10
8
6
4
2
Ambient temperature, °C
Load current, A
(a)
(b)
15 A type
–30 0 20 40 60 80
20
16
12
8
4
0
Ambient temperature, °C
Load current, A
(a)
(b)
2
7
6
15
20 A type
–30 0 20 40 60 80
20
16
12
8
4
2
0
Ambient temperature, °C
Load current, A
(a)
(b)
(a) With external heat sink
• A heat sink; optional heat sink (AQP-HS-20A) or
a 150×150×3.2 mm aluminum sheet (painted black)
• The heat sink surface area is the required area for
one solid-state relay.
b) Without external heat sink
If the mounting surface is not metallic and a heat
sink is not used, expose the bottom surface and
plate surface to improve heat dissipation.
The graphs show the characteristics when the relay
is mounted as shown in the right figure.
2-1. Non-repetitive surge current vs. carrying
time (10 A type) 2-2. Non-repetitive surge current vs. carrying
time (15 A type) 2-3. Non-repetitive surge current vs. carrying
time (20 A type)
1 2 3 4 5 7 10 20 30405070100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
1 2 3 4 5 7 10 20 30405070100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
1 2 3 4 5 7 10 20 30405070100
No. of cycles at 60 Hz
Non-repetitive surge current, A
20
0
40
60
80
100
120
140
160
180
200
220
,,
,,
,
,
,,
,
,,
,,,
,,,
,,,
,,,
,,
Washers are added
to lift the relay.
Hole for radiation
(40×35 mm)
3 mm or
greater
3. Input voltage vs. input current
(10 A, 15 A, 20 A type)
30
25
20
15
10
5
0
Input voltage, V
Input current, mA
015
510 202530
(4 to 6 V) (10 to 18 V)
(18 to 28 V)
NOTE
Regarding installation
DIN Rail Mounting
When the relay is mounted to a rail using
the DIN mounting rail (optional), the
rated capacity is limited to the character-
istics of a relay without a heat sink
attached.
For Cautions for Use
Go To Online Catalog
6/1/1999 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.