NOTE: For detailed information on purchasing options, contact your
local Allegro field applications engineer or sales representative.
Allegro MicroSystems, Inc. reserves the right to make, from time to time, revisions to the anticipated product life cycle plan
for a product to accommodate changes in production capabilities, alternative product availabilities, or market demand. The
information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no respon-
sibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use.
Recommended Substitutions:
Fully Integrated, Hall Effect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
For existing customer transition, and for new customers or new appli-
cations, refer to the ACS756 and ACS758.
Date of status change: November 2, 2009
This device is no longer in production. The device should not be
purchased for new design applications. Samples are no longer available.
Discontinued Product
ACS754xCB-130
Description
The Allegro ACS75x family of current sensor ICs provides
economical and precise solutions for current sensing in
industrial, automotive, commercial, and communications
systems. The device package allows for easy implementation by
the customer. Typical applications include motor control, load
detection and management, power supplies, and overcurrent
fault protection.
The device consists of a precision, low-offset linear Hall
circuit with a copper conduction path located near the die.
Applied current flowing through this copper conduction path
generates a magnetic field which the Hall IC converts into a
proportional voltage. Device accuracy is optimized through the
close proximity of the magnetic signal to the Hall transducer.
A precise, proportional voltage is provided by the low-offset,
chopper-stabilized BiCMOS Hall IC, which is programmed
for accuracy at the factory.
The output of the device has a positive slope (>VCC
/ 2) when an
increasing current flows through the primary copper conduction
path (from terminal 4 to terminal 5), which is the path used for
current sampling. The internal resistance of this conductive path
is typically 100 μΩ, providing low power loss. The thickness
of the copper conductor allows survival of the device at up to
ACS754130-DS Rev. 10
Features and Benefits
Monolithic Hall IC for high reliability
Single +5 V supply
3 kVRMS isolation voltage between terminals 4/5 and
pins 1/2/3 for up to 1 minute
35 kHz bandwidth
Automotive temperature range
End-of-line factory-trimmed for gain and offset
Ultra-low power loss: 100 μΩ internal conductor
resistance
Ratiometric output from supply voltage
Extremely stable output offset voltage
Small package size, with easy mounting capability
Output proportional to AC and DC currents
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
Continued on the next page…
Package: 5 pin package (leadform PFF)
Typical Application
+5 V
VOU
T
RF
CF
CBYP
0.1 µF
IP+
IP–
2
GND
4
5
ACS754
3
1
VIOUT
VCC
IP
Application 1. The ACS754 outputs an analog signal, VOUT
.
that varies linearly with the uni- or bi-directional AC or DC
primary sampled current, IP
, within the range specified. CF
is recommended for noise management, with values that
depend on the application.
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
2
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
5× overcurrent conditions. The terminals of the conductive path are
electrically isolated from the signal leads (pins 1 through 3). This
allows the ACS75x family of sensor ICs to be used in applications
requiring electrical isolation without the use of opto-isolators or
other costly isolation techniques.
The device is fully calibrated prior to shipment from the factory.
The ACS75x family is lead (Pb) free. All pins are coated with
100% matte tin, and there is no lead inside the package. The
heavy gauge leadframe is made of oxygen-free copper.
Description (continued)
Absolute Maximum Ratings
Characteristic Symbol Notes Rating Units
Supply Voltage VCC 16 V
Reverse Supply Voltage VRCC –16 V
Output Voltage VIOUT 16 V
Reverse Output Voltage VRIOUT –0.1 V
Maximum Basic Isolation Voltage VISO 353 VAC, 500 VDC, or Vpk V
Maximum Rated Input Current IIN 200 A
Output Current Source IOUT(Source) 3mA
Output Current Sink IOUT(Sink) 10 mA
Nominal Operating Ambient Temperature TA
Range L –40 to 150 ºC
Range S –20 to 85 ºC
Maximum Junction TJ(max) 165 ºC
Storage Temperature Tstg –65 to 170 ºC
TÜV America
Certificate Number:
U8V 04 11 54214 001
Fire and Electric Shock
EN60950-1:2001
Selection Guide
Part Number TOP
(°C)
Primary
Sampled
Current, IP
(A)
Sensitivity
Sens (Typ.)
(mV/A)
Package
Packing1
Terminals Signal Pins
ACS754LCB-130-PFF2–40 to 150 ±130 15 Formed Formed
Bulk, 170 pieces/bag
ACS754LCB-130-PSF2–40 to 150 ±130 15 Straight Formed
ACS754SCB-130-PFF2–20 to 85 ±130 15 Formed Formed
ACS754SCB-130-PSF2–20 to 85 ±130 15 Straight Formed
1Contact Allegro for additional packing options.
2Variant is in production but has been determined to be LAST TIME BUY. This classification indicates that the variant is obsolete and notice has been
given. Sale of the variant is currently restricted to existing customer applications. The variant should not be purchased for new design applications
because of obsolescence in the near future. Samples are no longer available. Status date change May 4, 2009. Deadline for receipt of LAST TIME
BUY orders is November 4, 2009.
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
3
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
IP+
IP–
VIOUT
GND
VCC
4
5
3
2
1
Terminal List Table
Number Name Description
1 VCC Device power supply pin
2 GND Signal ground pin
3 VIOUT Analog output signal pin
4 IP+ Terminal for current being sampled
5 IP– Terminal for current being sampled
Functional Block Diagram
Pin-out Diagram
Amp Out
VCC
+5 V
VIOUT
GND
Filter
Dynamic Offset
Cancellation
0.1 μF
IP–
IP+
Gain Temperature
Coefficient Offset
Voltage
Regulator
Trim Control
To all subcircuits
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
4
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
ELECTRICAL CHARACTERISTICS, over operating ambient temperature range unless otherwise stated
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Primary Sampled Current IP–130 130 A
Supply Voltage VCC 4.5 5.0 5.5 V
Supply Current ICC VCC = 5.0 V, output open 6.5 8 10 mA
Output Resistance ROUT IOUT = 1.2 mA 1 2 Ω
Output Capacitance Load CLOAD VOUT to GND 10 nF
Output Resistive Load RLOAD VOUT to GND 4.7 kΩ
Primary Conductor Resistance RPRIMARY IP = ±100A; TA = 25°C 100 μΩ
Isolation Voltage VISO Pins 1-3 and 4-5; 60 Hz, 1 minute 3.0 kV
PERFORMANCE CHARACTERISTICS, -20°C to +85°C, VCC = 5 V unless otherwise specified
Propagation time tPROP IP = ±50 A, TA = 25°C 4 μs
Response time tRESPONSE IP = ±50 A, TA = 25°C 11 μs
Rise time trIP = ±50 A, TA = 25°C 10 μs
Frequency Bandwidth f –3 dB , TA = 25°C 35 kHz
Sensitivity Sens Over full range of IP
, TA = 25°C 15 mV/A
Over full range of IP 14.2 15.8 mV/A
Noise VNOISE Peak-to-peak, TA = 25°C,
no external filter –40 mV
Linearity ELIN Over full range of IP ±0.8 %
Symmetry ESYM Over full range of IP 98 100 102 %
Zero Current Output Voltage VOUT(Q) I = 0 A, TA = 25°C VCC / 2 V
Electrical Offset Voltage
(Magnetic error not included) VOE
I = 0 A, TA = 25°C –10 10 mV
I = 0 A –20 20 mV
Magnetic Offset Error IERROM I = 0 A, after excursion of 130 A ±0.1 ±0.40 A
Total Output Error
(Including all offsets) ETOT
Over full range of IP
, TA = 25°C ±1.0 %
Over full range of IP ±5.0 %
PERFORMANCE CHARACTERISTICS, -40°C to +150°C, VCC = 5 V unless otherwise specified
Propagation time tPROP IP = ±50 A, TA = 25°C 4 μs
Response time tRESPONSE IP = ±50 A, TA = 25°C 11 μs
Rise time trIP = ±50 A, TA = 25°C 10 μs
Frequency Bandwidth f –3 dB , TA = 25°C 35 kHz
Sensitivity Sens Over full range of IP
, TA = 25°C 15 mV/A
Over full range of IP 13.8 16.2 mV/A
Noise VNOISE Peak-to-peak, TA = 25°C,
no external filter –40 mV
Linearity ELIN Over full range of IP ±1.5 %
Symmetry ESYM Over full range of IP 98 100 102 %
Zero Current Output Voltage VOUT(Q) I = 0 A, TA = 25°C VCC / 2 V
Electrical Offset Voltage
(Magnetic error not included) VOE
I = 0 A, TA = 25°C –10 10 mV
I = 0 A –35 35 mV
Magnetic Offset Error IERROM I = 0 A, after excursion of 130 A ±0.1 ±0.40 A
Total Output Error
(Including all offsets) ETOT
Over full range of IP
, TA = 25°C ±1.0 %
Over full range of IP ±8.0 %
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
5
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
Sensitivity (Sens). The change in device output in response to a
1 A change through the primary conductor. The sensitivity is the
product of the magnetic circuit sensitivity (G / A) and the linear
IC amplifier gain (mV/G). The linear IC amplifier gain is pro-
grammed at the factory to optimize the sensitivity (mV/A) for the
full-scale current of the device.
Noise (VNOISE). The product of the linear IC amplifier gain
(mV/G) and the noise floor for the Allegro Hall effect linear IC
(1 G). The noise floor is derived from the thermal and shot
noise observed in Hall elements. Dividing the noise (mV) by the
sensitivity (mV/A) provides the smallest current that the device is
able to resolve.
Linearity (ELIN). The degree to which the voltage output from
the IC varies in direct proportion to the primary current through
its full-scale amplitude. Nonlinearity in the output can be attrib-
uted to the saturation of the flux concentrator approaching the
full-scale current. The following equation is used to derive the
linearity:
where
gain = the gain variation as a function of temperature
changes from 25ºC,
% sat = the percentage of saturation of the flux concentra-
tor, which becomes significant as the current being sampled
approaches full-scale ±IP , and
VIOUT_full-scale amperes = the output voltage (V) when the
sampled current approximates full-scale ±IP .
Symmetry (ESYM). The degree to which the absolute voltage
output from the IC varies in proportion to either a positive or
negative full-scale primary current. The following equation is
used to derive symmetry:
Quiescent output voltage (VIOUT(Q)). The output of the device
when the primary current is zero. For a unipolar supply voltage,
it nominally remains at VCC 2. Thus, VCC = 5 V translates into
VIOUT(Q) = 2.5 V. Variation in VOUT(Q) can be attributed to the res-
olution of the Allegro linear IC quiescent voltage trim, magnetic
hysteresis, and thermal drift.
Electrical offset voltage (VOE). The deviation of the device out-
put from its ideal quiescent value of VCC 2 due to nonmagnetic
causes.
Magnetic offset error (IERROM). The magnetic offset is due to
the residual magnetism (remnant field) of the core material. The
magnetic offset error is highest when the magnetic circuit has
been saturated, usually when the device has been subjected to a
full-scale or high-current overload condition. The magnetic offset
is largely dependent on the material used as a flux concentrator.
The larger magnetic offsets are observed at the lower operating
temperatures.
Accuracy (ETOT). The accuracy represents the maximum devia-
tion of the actual output from its ideal value. This is also known
as the total output error. The accuracy is illustrated graphically in
the output voltage versus current chart on the following page.
Accuracy is divided into four areas:
 0 A at 25°C. Accuracy at the zero current flow at 25°C, with-
out the effects of temperature.
 0 A over Δ temperature. Accuracy at the zero current flow
including temperature effects.
 Full-scale current at 25°C. Accuracy at the the full-scale current
at 25°C, without the effects of temperature.
 Full-scale current over Δ temperature. Accuracy at the full-
scale current flow including temperature effects.
Definitions of Accuracy Characteristics
100 1–
[{
[{
VIOUT_full-scale amperes VIOUT(Q)
Δ gain × % sat ( )
2 (VIOUT_half-scale amperes VIOUT(Q) )
100
VIOUT_+ full-scale amperes VIOUT(Q)
VIOUT(Q) VIOUT_–full-scale amperes

Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
6
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
Definitions of Dynamic Response Characteristics
Propagation delay (tPROP). The time required for the device
output to reflect a change in the primary current signal. Propaga-
tion delay is attributed to inductive loading within the linear IC
package, as well as in the inductive loop formed by the primary
conductor geometry. Propagation delay can be considered as a
fixed time offset and may be compensated.
Primary Current
Transducer Output
90
0
I (%)
Propagation Time, tPROP
t
Primary Current
Transducer Output
90
0
I (%)
Response Time, tRESPONSE t
Primary Current
Transducer Output
90
10
0
I (%)
Rise Time, trt
Rise time (tr). The time interval between a) when the device
reaches 10% of its full scale value, and b) when it reaches 90%
of its full scale value. The rise time to a step response is used to
derive the bandwidth of the device, in which ƒ(–3 dB) = 0.35 / tr.
Both tr and tRESPONSE are detrimentally affected by eddy current
losses observed in the conductive IC ground plane.
Response time (tRESPONSE). The time interval between a) when
the primary current signal reaches 90% of its final value, and b)
when the device reaches 90% of its output corresponding to the
applied current.
Output Voltage versus Sampled Current
Accuracy at 0 A and at Full-Scale Current
Increasing VIOUT
(V)
+IP (A)
Accuracy
Accuracy
Accuracy
25°C Only
Accuracy
25°C Only
Accuracy
25°C Only
Accuracy
0 A
vrOe $Temperature
Average
VIOUT
–IP (A)
vrOe $Temperature
vrOe $Temperature
Decreasing VIOUT
(V)
IP(min)
IP(max)
Full Scale
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
7
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
Step Response
No external filter, TA=25°C
x130 Device
Output (mV)
130 A
Excitation
Signal
Fully Integrated, Hall Ef fect-Based Linear Current Sensor IC
with High Voltage Isolation and a Low-Resistance Current Conductor
ACS754xCB-130
8
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
Copyright ©2004-2009, Allegro MicroSystems, Inc.
The products described herein are manufactured under one or more of the following U.S. patents: 5,619,137; 5,621,319; 6,781,359; 7,075,287;
7,166,807; 7,265,531; 7,425,821; or other patents pending.
Allegro MicroSystems, Inc. reserves the right to make, from time to time, such de par tures from the detail spec i fi ca tions as may be required to per-
mit improvements in the per for mance, reliability, or manufacturability of its products. Before placing an order, the user is cautioned to verify that the
information being relied upon is current.
Allegro’s products are not to be used in life support devices or systems, if a failure of an Allegro product can reasonably be expected to cause the
failure of that life support device or system, or to affect the safety or effectiveness of that device or system.
The in for ma tion in clud ed herein is believed to be ac cu rate and reliable. How ev er, Allegro MicroSystems, Inc. assumes no re spon si bil i ty for its use;
nor for any in fringe ment of patents or other rights of third parties which may result from its use.
For the latest version of this document, visit our website:
www.allegromicro.com
Package CB, 5-pin package
Leadform PFF
Creepage distance, current terminals to signal pins: 7.25 mm
Clearance distance, current terminals to signal pins: 7.25 mm
Package mass: 4.63 g typical
4
R1
1.91
321.4
0.5
R3
0.8
1.5
0.5
R2
Perimeter through-holes recommended
1º±2°
5º±5°
B
23
14.0±0.2
17.5±0.2
4.0±0.2
3.0±0.2
2.9±0.2
3.5±0.2
3.5±0.2
10.00±0.10
13.00±0.10
0.51±0.10
4.40±0.10
7.00±0.10
1.9±0.2
1.50±0.10
1
45
A
A
C
B
C
B
Branding scale and appearance at supplier discretion
Dambar removal intrusion
For Reference Only; not for tooling use (reference DWG-9111, DWG-9110)
Dimensions in millimeters
Dimensions exclusive of mold flash, gate burrs, and dambar protrusions
Exact case and lead configuration at supplier discretion within limits shown
Standard Branding Reference View
N = Device part number
T = Temperature code
A = Amperage range
L = Lot number
Y = Last two digits of year of manufacture
W = Week of manufacture
= Supplier emblem
Branded
Face
0.381+0.060
–0.030
1
NNNNNNN
TTT - AAA
LLLLLLL
YYWW
PCB Layout Reference View