General Purpose Relay LY * Arc barrier equipped. * High dielectric strength (2,000 VAC). * Long dependable service life assured by Ag-Alloy contacts. * Choose models with single or bifurcated contacts, LED indicator, diode surge suppression, push-to-test button, or RC circuit. * UL, CSA, TUV, and CE approvals on all standard LY Relay Part Numbers. Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., LY1-DC6). Type Terminal Contact form Model Single contact Standard bracket mounting Standard Plug-in/solder Bifurcated contact Upper mounting bracket Standard bracket mounting Upper mounting bracket SPDT LY1 LY1F -- DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F -- -- 4PDT LY4 LY4F -- -- SPDT LY1-0 -- -- -- DPDT LY2-0 -- LY2Z-0 -- 3PDT LY3-0 -- -- -- 4PDT LY4-0 -- -- -- SPDT LY1N -- -- -- DPDT LY2N -- LY2ZN -- 3PDT LY3N -- -- -- 4PDT LY4N -- -- -- SPDT LY1-D -- -- -- DPDT LY2-D -- LY2Z-D -- 3PDT LY3-D -- -- -- 4PDT LY4-D -- -- -- LED indicator and diode surge suppression SPDT LY1N-D2 -- -- -- DPDT LY2N-D2 -- LY2ZN-D2 -- 4PDT LY4N-D2 -- -- -- RC circuit SPDT LY1-CR -- -- -- DPDT LY2-CR -- LY2Z-CR -- SPDT LY1N-CR -- -- -- DPDT LY2N-CR -- LY2ZN-CR -- PCB LED indicator Diode surge suppression LED indicator and RC circuit Plug-in/solder -- Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative. 2. To order connecting sockets and mounting tracks, see "Accessories" section. 3. Relays with RC circuit are only available in AC coil voltages of 100 VAC or greater. General Purpose Relay LY 285 Type Terminal Contact form Model Single contact Standard bracket mounting Push-to-test button Plug-in/solder LED indicator and push-to-test button Plug-in/solder Bifurcated contact Upper mounting bracket Standard bracket mounting Upper mounting bracket SPDT LY1l4 -- -- -- DPDT LY2l4 -- LY2Zl2 -- 3PDT LY3l4 -- -- -- 4PDT LY4l4 -- -- -- DPDT LY2l4N -- LY2Zl2N -- 4PDT LY4l4N -- -- -- Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative. 2. To order connecting sockets and mounting tracks, see "Accessories" section. Accessories Connecting Sockets To Order: Select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the following charts. Track Mounted Sockets Relay Socket* Relay hold-down clip Standard SPDT PTF08A-E Mounting track RC circuit PYC-A1 Y92H-3 PFP-100N/PFP-50N & DPDT PFP-M or PFP-100N2 3PDT PTF11A 4PDT PTF14A-E PFP-S (Option spacer) * Track mounted socket can be used as a front connecting socket. Back Connecting Sockets Relay SPDT Solder terminal socket Wire wrap terminal socket Relay hold-down clip Standard PYC-P Push-to-test PYC-P2 RC circuit PYC-1 Socket Mounting Plate Mtg. plate PYC-S 1 PT08 PT08QN PYP-1 3PDT PT11 PT11QN PTP-1-3 4PDT PT14 PT14QN PTP-1 10 - 12 18 - PYP-18 - PTP-12 - PTP-10 - - DPDT Note: Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length. Relay PC terminal socket Relay hold-down clip Standard SPDT PT08-0 PYC-P DPDT 3PDT PT11-0 4PDT PT14-0 286 General Purpose Relay LY Push-to-test PYC-P2 RC circuit PYC-1 Specifications Contact Data Load Single contact SPDT Resistive load (p.f. = 1) Rated load Bifurcated contact DPDT, 3PDT, 4PDT Inductive load (p.f. = 0.4) (L/R = 7 ms) Resistive load (p.f. = 1) DPDT Inductive load (p.f. = 0.4) (L/R = 7 ms) Resistive load (p.f. = 1) Inductive load (p.f. = 0.4) (L/R = 7 ms) 15 A at 110 VAC 10 A at 110 VAC 10 A at 110 VAC 7.5 A at 110 VAC 5 A at 110 VAC 4 A at 110 VAC 15 A at 24 VDC 7 A at 24 VDC 10 A at 24 VDC 5 A at 24 VDC 5 A at 24 VDC 4 A at 24 VDC Contact material Ag-Alloy Carry current 15 A Max. operating voltage 250 VAC 125 VDC Max. operating current 15 A Max. switching capacity 1,700 VA 1,100 VA 1,100 VA 825 VA 550 VA 440 VA 360 W 170 W 240 W 120 W 120 W 100 W Min. permissible load 100 mA, 5 VDC 10 A 7A 10 A 7A 10 mA, 5 VDC Coil Data 1- and 2-pole Types - AC Rated voltage (V) Rated current (mA) 50 Hz 60 Hz Coil resistance () Coil inductance (ref. value) (H) Armature OFF Armature ON 6 214.10 183 12.20 0.04 0.08 12 106.50 91 46 0.17 0.33 24 53.80 46 180 0.69 1.30 50 25.70 22 788 3.22 5.66 100/110 11.70/12.90 10/11 3,750 14.54 24.60 110/120 9.90/10.80 8.40/9.20 4,430 19.20 32.10 200/220 6.20/6.80 5.30/5.80 12,950 54.75 94.07 220/240 4.80/5.30 4.20/4.60 18,790 83.50 136.40 Pick-up voltage Dropout voltage Maximum voltage (% of rated voltage) 80% max. 30% min. 110% Power consumption (VA, W) Approx. 1.00 to 1.20 (60 Hz) Approx. 0.90 to 1.10 (60 Hz) 1- and 2-pole Types - DC Rated voltage (V) Rated current (mA) Coil resistance () Coil inductance (ref. value) (H) Armature Armature OFF ON 6 150 40 0.16 0.33 12 75 160 0.73 1.37 24 36.90 650 3.20 5.72 48 18.50 2,600 10.60 21 100/110 9.10/10 11,000 45.60 86.20 Pick-up Dropout Maximum voltage voltage voltage (% of rated voltage) 80% max. 10% min. 110% Power consumption (VA, W) Approx. 0.90 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with tolerances of +15%, -20% for AC rated current, and 15% for DC rated coil resistance. 2. The AC coil resistance and inductance are reference values at 60 Hz. 3. The performance characteristics are measured at a coil temperature of 23C (73F). 4. Class B coil insulation is available. General Purpose Relay LY 287 3-pole Type - AC Rated voltage (V) Rated current (mA) 50 Hz Coil resistance () 60 Hz Coil inductance (ref. value) (H) Armature OFF Armature ON 6 310 270 6.70 0.03 0.05 12 159 134 24 0.12 0.21 24 80 67 100 0.44 0.79 50 38 33 410 2.24 3.87 100/110 15.90/18.30 13.60/15.60 2,300 10.50 18.50 120 17.30 2,450 11.50 20.60 200/220 10.50/11.60 9.00/9.90 8,650 34.80 59.50 240 9.40 10,400 38.60 74.60 14.8 8 Pick-up voltage Dropout voltage Maximum voltage Power consumption (VA, W) (% of rated voltage) 80% max. 30% min. 110% Approx. 1.60 to 2.00 (60 Hz) 3-pole Type - DC Rated voltage (V) Rated current (mA) Coil resistance () Coil inductance (ref. value) (H) Armature OFF Pick-up voltage Armature ON 6 234 25.70 0.11 0.21 12 112 107 0.45 0.98 24 58.60 410 1.89 3.87 48 28.20 1,700 8.53 13.90 100/110 12.70/13 8,500 29.60 54.30 Dropout voltage Maximum voltage (% of rated voltage) 80% max. 10% min. 110% Power consumption (VA, W) Approx. 1.40 4-pole Type - AC Rated voltage (V) Rated current (mA) 50 Hz 60 Hz Coil resistance () Coil inductance (ref. value) (H) Armature OFF Armature ON 6 386 330 5 0.02 0.04 12 199 170 20 0.10 0.17 24 93.60 80 78 0.38 0.67 50 46.80 40 350 1.74 2.88 100/110 22.50/25.50 19/21.80 1,800 10.50 17.30 120 19.00 2,200 9.30 19 200/220 11.50/13.10 9.80/11.20 6,700 33.10 57.90 240 11.00 9,000 33.20 63.40 16.40 9.50 Pick-up voltage Dropout voltage Maximum voltage (% of rated voltage) 80% max. 30% min. 110% Power consumption (VA, W) Approx. 1.95 to 2.50 (60 Hz) 4-pole Type - DC Rated current (mA) Rated voltage (V) Coil resistance () Coil inductance (ref. value) (H) Armature OFF Pick-up voltage Armature ON 6 240 25 0.09 0.21 12 120 100 0.39 0.84 24 69 350 1.41 2.91 48 30 1,600 6.39 13.60 100/110 15/15.90 6,900 32 63.70 Dropout voltage Maximum voltage (% of rated voltage) 80% max. 10% min. 110% Power consumption (VA, W) Approx. 1.50 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with tolerances of +15%, -20% for AC rated current, and 15% for DC rated coil resistance. 2. The AC coil resistance and inductance are reference values at 60 Hz. 3. The performance characteristics are measured at a coil temperature of 23C (73F). 4. Class B coil insulation is available. 288 General Purpose Relay LY Characteristics Contact resistance 50 m max. Operate time 25 ms max. Release time Operating frequency 25 ms max. Mechanically 18,000 operations/hour Under rated load 1,800 operations/hour Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute 1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity Vibration Shock Ambient temperature Mechanical durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude Mechanical durability 1,000 m/s2 (approx. 100 G) Malfunction durability 200 m/s2 (approx. 20 G) Operating LY1, LY2, LY3: -25 to 55C; LY4 =-25 to 40C Humidity Service Life 35 to 85% RH Mechanically AC: 50 million operations min. (at operating frequency of 18,000 operations/hour) DC: 100 million operations min. (at operating frequency of 18,000 operations/hour) Electrically See "Characteristic Data" Weight SPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz) 4PDT: Approx. 70 g (2.47 oz) Note: Data shown are of initial value. Characteristic Data Maximum switching capacity Rated operating voltage (V) Rated operating voltage (V) Rated operating current (A) LY2Z Rated operating current (A) LY3, LY4 Rated operating current (A) LY2 Rated operating current (A) LY1 Rated operating voltage (V) Rated operating voltage (V) Electrical service life Switching current (A) Switching current (A) Service Life (X106 operations) LY2Z Service Life (X106 operations) LY3, LY4 Service Life (X106 operations) LY2 Service Life (X106 operations) LY1 Switching current (A) Switching current (A) General Purpose Relay LY 289 Dimensions Unit: mm (inch) Relays LY1 Terminal arrangement (Bottom view) LY2 LY3 Terminal arrangement (Bottom view) LY4 LY1-0, LY2-0, LY3-0, LY4-0 LY1F, LY2F SPTD Mounting holes Note: The above drawing shows LY1F. With LY2F, dimension "*" should read as eight 3.05 mm (0.12 in) dia. holes. General Purpose Relay Terminal arrangement (Bottom view) Mounting holes for LY1-0, LY2-0, LY3-0, LY4-0 (Bottom view) Note: The above drawing shows LY2-0. With LY1-0, dimension "*" should read as eight 6.35 (.25). 290 Terminal arrangement (Bottom view) LY LY3F DPDT 3PDT 4PDT Mounting holes LY4F Mounting holes LY1S, LY2S Round hole Rectangular hole LY3S Round hole Rectangular hole LY4S Round hole Rectangular hole Note: The above drawing shows LY2S-US. With LY1S-US, dimension "*" should read as eight 2.03 mm (0.08 in) dia. holes. General Purpose Relay LY 291 Accessories Unit: mm (inch) Track mounted sockets (UL File No. E87929) (CSA Report No. LR31928) PTF08A (see note 3) Terminal arrangement/ mounting holes (Top view) PTF11A Terminal arrangement/ mounting holes (Top view) Track mounting sockets (UL File No. E87929) (CSA Report No. LR31928) PTF14A (see note 3) Terminal arrangement/ mounting holes (Top view) Mounting height of relay with socket (Applies to all PTFA sockets) Note: 1. UL/CSA does not apply to wire wrap (Q) type sockets. 2. Values in brackets for LYCR. 3. PTF08A-E and PTF14A-E = touch safe screws. Height = 33 mm max. Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT08 292 Terminal arrangement/ (Bottom view) General Purpose Relay LY PT11 Terminal arrangement/ (Bottom view) Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT14 Terminal arrangement (Bottom view) Mounting height of relay with socket (Applies to all PT sockets) PT Note: Values in brackets for LYCR. Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT08QN Panel cut-out and terminal arrangement are the same as Type PT08. PT11QN Panel cut-out and terminal arrangement are the same as Type PT11. PT14QN Panel cut-out and terminal arrangement are the same as Type PT14. Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT08-0 Terminal arrangement is the same as Type PT08. Mounting holes (Bottom view) PT11-0 Terminal arrangement is the same as Type PT11. Mounting holes (Bottom view) Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT14-0 Terminal arrangement is the same as Type PT14. Mounting holes (Bottom view) General Purpose Relay LY 293 Unit: mm (inch) Relay hold-down clips PYC-A1 For PTFA socket PYC-S For relay mounting plates (Applicable to Type PYP-1 and PYP-18 socket mounting plates only.) PYC-P For PT socket Y92H-3 For RC circuit type PYC-1 For RC circuit type Relay hold-down clips PYC-P2 For push-to-test button type with PT socket Mounting track/end plate/spacer PFP-100N, PFP-50N (Conforming to EN 50022) PFP-100N2 (Conforming to EN 50022) 16 7.30.15 4.5 4.5 350.3 15 25 25 10 25 1000 (500)* 10 25 * 15 (5) 350.3 27 270.15 1 15 25 25 10 25 10004 25 15 10 24 29.2 1 1.5 * The figure in parenthesis is for PFP-50N. *This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N. ** L = Length PFP-50N L = 497.84 mm (19.60 in) PFP-100N L = 990.60 mm (39.00 in) PFP-100N2 L = 990.60 mm (39.00 in) ***A total of twelve 24.89 x 4.57 mm (0.98 x 0.18 in) elliptic holes are provided, with six holes cut from each end of the track at a pitch of 9.91 (0.39) between holes. 294 General Purpose Relay LY PFP-M end plate PFP-S spacer Socket mounting plates [t=1.52 (.06)] PYP-1 PTP-10 PTP-1-3 Number of socket specs. Socket needed 1 10 12 18 PT08, PT08QN PYP-1 - - PYP-18 PT11, PT11QN PTP-1-3 - PTP-1-2 _ PT14, PT14QN PTP-1 PTP-10 - - PTP-10 PTP-12 PTP-1 PYP-18 PTP-12 General Purpose Relay LY 295 Relay Options LED Indicator Specifications and dimensions same as the Standard Type with the following exception. With the LED indicator type, the rated current is approximately 0 to 5.0 mA higher than the Standard Type. Terminal arrangement/Internal connections (Bottom view) LY2N DC coil rating type AC coil rating type 1 2 1 2 3 4 3 4 5 6 5 6 7 8 7 8 Note: 1. The coil terminals 10 and 11 of Type LY3N become (-) and (+) and terminals 13 and 14 of Type LY4N become (-) and (+), respectively. 2. Pay special attention to the polarities when using the DC type. Diode Surge Suppression Specifications and dimensions same as the Standard Type with the following exception. Ambient operating temperature: -25 to 40C (-13 to 104F) Without Diode With Diode Terminal arrangement/Internal connections (Bottom view) LY2(N)-D(2) LY2-D 6, 12, 24, 48 100/110 VDC Note: 1. 2. 3. 4. 296 LY2N-D2 6, 12, 24, 48 VDC Pay special attention to the polarities when using the DC type. The release time is somewhat longer, but satisfies the standard specifications of 25 ms. The reverse-breakdown voltage of the diode is 1,000 VDC. Available on DC versions only. General Purpose Relay LY LY2N-D2 100/110 VDC Relay Options RC Circuit Specifications and dimensions same as the Standard Type with the following exceptions. Characteristic Data Without RC circuit With RC circuit LY1-CR, LY2(Z)-CR Terminal arrangement/Internal connections (Bottom view) LY1-CR LY2(Z)-CR Note: 1. The above drawing shows LY2(Z)-CR. With LY1-CR, "*" should read eight 2.03 mm (0.08 in) dia. holes. 2. Available on AC versions only. Push-to-test Button Specifications and dimensions same as the Standard Type with the following exceptions. LYI2 LY1I2, LY2I2 Note: Type LY1I2 has the same dimensions and appearances as Type LY2I2 shown except that dimensions "*" is 2.03 mm (0.08 in) dia. holes. LY3I2 LY4I2 General Purpose Relay LY 297 Approvals UL Recognized Type (File No. E41643) Type LY1 Contact form SPDT Coil ratings Contact ratings Number of test operations 6 to 240 VAC 15A, 30VDC (Resistive), 40C 6 to 120 VDC 15A, 240VAC (General use), 40C 6 x 103 TV-5, 120VAC, 40C 25 x 103 1/2HP, 120VAC, 50C LY2 DPDT 15A, 28VDC (Resistive), 40C 6 x 103 15A, 120VAC (Resistive), 40C 12A, 240VAC (General use), 40C 1/2HP, 120VAC, 50C 25 x 103 TV-3, 120VAC, 40C LY3 LY4 3PDT 10A, 30VDC (Resistive), 40C (Same polarity ) 4PDT 10A, 240VAC (General use), 40C (Same polarity ) LY2Z (Bifurcated) DPDT 7A, 240VAC (General use), 40C 6 x 103 1/2HP, 240VAC, 40C 6 x 103 7A, 28VDC (Resistive), 40C CSA Certified Type (File No. LR31928) Type LY1 Contact form SPDT Coil ratings 6 to 240 VAC 6 to 120 VDC Contact ratings 15 A, 120 VAC (Inductive) 10 A, 240 VAC (Inductive) 15 A, 28 VDC (Resistive) TV-5 (ACTV) LY2 DPDT 13 A, 28 VDC (Resistive) 12 A, 120 VAC (Inductive) 10 A, 240 VAC (Inductive) 1/3 HP, 120 VAC (Motor) TV-3 (ACTV) LY3 LY3 3PDT 10 A, 240 VAC (Inductive) 4PDT 10 A, 28 VDC (Resistive) VDE Approved Type (File No. 9903 [SPDT, DPDT & 3PDT], File No. 9947 [4PDT]) Type LY-VD Contact form SPDT LY-VD Coil ratings 6, 12, 24, 50, Contact ratings 10 A, 220 VAC (Resistive) 110, 220 VAC 10 A, 28 VDC (Resistive) and 6, 12, 24, 7 A, 220 VAC (Inductive) 48, 110 VDC 7 A, 28 VDC (Inductive) DPDT 7 A, 220 VAC (Resistive) 3PDT 7 A, 28 VDC (Resistive) 4PDT 4 A, 28 VDC and 4A, 220 VAC (Inductive) LR (Lloyd's Register) Approved Type (File No. 562KOB-204523) Type LY Contact form Coil ratings Contact ratings DPDT 6 to 240 VAC 7.5 A, 230 VAC (Inductive) 4PDT 6 to 110 VDC 5 A, 24 VDC (Inductive) SEV Listed Type (File No. D7 91/82 [2- & 4-pole], D 91/204a [1- & 3-pole]) Type Contact form Coil ratings Contact ratings LY-SV SPDT 6 to 240 VAC 15 A, 220 VAC (Resistive) LY-SV DPDT 6 to 110 VDC 15 A, 24 VDC (Resistive) 10 A, 220 VAC (Resistive) 3PDT 10 A, 24 VDC (Resistive) 4PDT Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. 298 General Purpose Relay LY Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. 14 2010.1 In the interest of product improvement, are subject change without notice. To convert millimeters into inches, multiply by 0.03937. To convert gramsspecifications into ounces, multiply by to 0.03527. OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu J002-E1-10 06/09 Note: Specifications are subject to change. (c) 2010 Omron Electronics LLC Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: LY2S-AC24 PT1/4 D=6.4 PYC PTP-1 FOR LY