DPA423-426 DPA-SwitchTM Family Highly Integrated DC-DC Converter ICs for Distributed Power Architectures Product Highlights Highly Integrated Solution * Eliminates 20-50 external components-saves space, cost * Integrates 220 V high frequency MOSFET, PWM control * Lower cost plastic DIP surface mount (G package) and through-hole (P package) options for designs 35 W Superior Performance and Flexibility * Eliminates all external current sensing circuitry * Built-in auto-restart for output overload/open loop protection * Pin selectable 300/400 kHz fixed frequency * Wide input (line) voltage range: 16-75 VDC * Source connected tab reduces EMI * Line under-voltage (UV) detection: meets ETSI standards * Line overvoltage (OV) shutdown protection * Low cost synchronous rectification: line UV/OV shut down limits gate drive voltage range from transformer winding * Fully integrated soft-start for minimum stress/overshoot * Externally programmable current limit * Supports forward or flyback topology * Cycle skipping: regulation to zero load without pre-load * Hysteretic thermal shutdown for automatic fault recovery (R) EcoSmart - Energy Efficient * Extremely low consumption at no load * Cycle skipping at light load for high standby efficiency Applications * Telco central office equipment: xDSL, ISDN, PABX, etc. * Distributed power architectures (24 V/48 V bus, etc.) * Digital feature phones, VoIP phones, PoE * Industrial controls (24 V/48 V) Description The DPA-Switch IC family introduces a highly integrated solution for DC-DC conversion applications in the 16-75 VDC input range. DPA-Switch uses the same proven topology as TOPSwitch, cost effectively integrating the high voltage power MOSFET, PWM control, fault protection and other control circuitry onto a single CMOS chip. High performance features are enabled with three user configurable pins. VO SENSE CIRCUIT DPA-Switch VIN L D CONTROL RESET/ CLAMP CIRCUIT S X C F PI-2770-032002 Figure 1. Typical Forward Converter Application. OUTPUT POWER TABLE 36-75 VDC INPUT RANGE (FORWARD)2,4 Total Device Dissipation3 0.5 W PRODUCT4 DPA423 DPA424 DPA425 DPA426 12 W 16 W 23 W 25 W 1 W 2.5 W 4W 6W 16 W 23 W 35 W 32 W 50 W 62 W 35 W 55 W 70 W 83 W Max Power Output1 18 W 35 W 70 W 100 W 36-75 VDC INPUT RANGE (FLYBACK)2 Total Device3 Dissipation 0.5 W 0.75 W 1W 1.5 W PRODUCT4 DPA423 DPA424 DPA425 9W 13 W 10 W 14.5 W 18 W 24 W -5 -5 -5 25.5 W Max Power Output1 13 W 26 W 52 W Table 1. Notes: 1. Maximum output power is limited by device internal current limit. 2. See Applications Considerations section for complete description of assumptions and for output powers with other input voltage ranges. 3. For device dissipation of 1.5 W or below, use P or G packages. Device dissipation above 1.5 W is possible only with R package. 4. See Part Ordering Information. 5. Due to higher switching losses, the DPA425 may not deliver additional power compared to a smaller device. The following transparent or built-in features are also provided: soft-start, cycle skipping down to zero load and hysteretic thermal shutdown. In addition, all critical parameters (i.e. current limit, frequency, PWM gain) have tight temperature and absolute tolerance, to simplify design and optimize system cost. January 2004 DPA423-426 Section List Functional Block Diagram ......................................................................................................................................... 3 Pin Functional Description ........................................................................................................................................ 3 DPA-Switch Family Functional Description .............................................................................................................. 4 CONTROL (C) Pin Operation ................................................................................................................................. 4 Oscillator and Switching Frequency ....................................................................................................................... 5 Pulse Width Modulator & Maximum Duty Cycle ..................................................................................................... 6 Minimum Duty Cycle and Cycle Skipping ............................................................................................................... 6 Error Amplifier ......................................................................................................................................................... 6 On-chip Current Limit with External Programmability ............................................................................................. 6 Line Under-Voltage Detection (UV) ........................................................................................................................ 6 Line Overvoltage Shutdown (OV) ........................................................................................................................... 7 Line Feed Forward with DCMAX Reduction .............................................................................................................. 7 Remote ON/OFF .................................................................................................................................................... 7 Synchronization ...................................................................................................................................................... 8 Soft-Start ................................................................................................................................................................ 8 Shutdown/Auto-Restart .......................................................................................................................................... 8 Hysteretic Over-Temperature Protection ................................................................................................................ 8 Bandgap Reference ................................................................................................................................................ 8 High-Voltage Bias Current Source .......................................................................................................................... 8 Using Feature Pins ...................................................................................................................................................... 9 FREQUENCY (F) Pin Operation ............................................................................................................................. 9 LINE-SENSE (L) Pin Operation .............................................................................................................................. 9 EXTERNAL CURRENT LIMIT (X) Pin Operation ................................................................................................... 9 Typical Uses of FREQUENCY (F) Pin ...................................................................................................................... 12 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins ....................................................... 12 Application Examples ............................................................................................................................................... 15 Key Application Considerations .............................................................................................................................. 17 DPA-Switch Design Considerations ...................................................................................................................... 17 DPA-Switch Layout Considerations ...................................................................................................................... 18 Quick Design Checklist ......................................................................................................................................... 19 Design Tools ......................................................................................................................................................... 19 Product Specifications and Test Conditions .......................................................................................................... 21 Typical Performance Characteristics ..................................................................................................................... 27 Part Ordering Information ........................................................................................................................................ 31 Package Outlines ...................................................................................................................................................... 32 2 K 1/04 DPA423-426 VC 0 DRAIN (D) CONTROL (C) ZC INTERNAL SUPPLY 1 SHUNT REGULATOR/ ERROR AMPLIFIER + SOFT START 5.8 V 4.8 V - - 5.8 V + INTERNAL UV COMPARATOR IFB VI (LIMIT) CURRENT LIMIT ADJUST SOFT START + VBG + VT SHUTDOWN/ AUTO-RESTART EXTERNAL CURRENT LIMIT (X) 1V VBG OV/UV LINE SENSE DCMAX CONTROLLED TURN-ON GATE DRIVER STOP SOFTSTART DMAX DCMAX CLOCK 300/400 kHz FREQUENCY (F) CURRENT LIMIT COMPARATOR HYSTERETIC THERMAL SHUTDOWN STOP LOGIC LINE-SENSE (L) - /8 ON/OFF SAW S + OSCILLATOR Q LEADING EDGE BLANKING R PWM COMPARATOR RE CYCLE SKIPPING SOURCE (S) PI-2760-070501 PI-2760-070501 Figure 2. Functional Block Diagram. Pin Functional Description DRAIN (D) Pin: High voltage power MOSFET drain output. The internal startup bias current is drawn from this pin through a switched highvoltage current source. Internal current limit sense point for drain current. CONTROL (C) Pin: Error amplifier and feedback current input pin for duty cycle control. Internal shunt regulator connection to provide internal bias current during normal operation. It is also used as the connection point for the supply bypass and auto-restart/ compensation capacitor. LINE-SENSE (L) Pin: Input pin for overvoltage (OV), under-voltage (UV) lock out, line feed forward with the maximum duty cycle (DCMAX) reduction, remote ON/OFF and synchronization. A connection to SOURCE pin disables all functions on this pin. EXTERNAL CURRENT LIMIT (X) Pin: Input pin for external current limit adjustment and remote ON/OFF. A connection to SOURCE pin disables all functions on this pin. FREQUENCY (F) Pin: Input pin for selecting switching frequency: 400 kHz if connected to SOURCE pin and 300 kHz if connected to CONTROL pin. SOURCE (S) Pin: Output MOSFET source connection for the power return. Primary side control circuit common and reference point. P Package (DIP-8) G Package (SMD-8) C 1 5 S L 2 6 S X 3 7 D F 4 8 S R Package (TO-263-7C) 123 4 5 CL X S F Tab Internally Connected to SOURCE Pin (See layout considerations) 7 D PI-3822-012104 Figure 3. Pin Configuration (top view). K 1/04 3 DPA423-426 DPA-Switch Family Functional Description In addition to the standard TOPSwitch features, such as the high-voltage start-up, the cycle-by-cycle current limiting, loop compensation circuitry, auto-restart and thermal shutdown, DPA-Switch also offers many advanced features that reduce system cost and increase power supply performance and design flexibility. Following is a summary of the advanced features: 1. A fully integrated 5 ms soft-start limits peak currents and voltages during start-up and reduces or eliminates output overshoot in most applications. 2. A 75% maximum duty cycle (DCMAX) together with the line feed forward with DCMAX reduction feature makes DPA-Switch well suited for both flyback and forward topologies. 3. High switching frequency (400 kHz/300 kHz, pin selectable) allows the use of smaller size transformers and offers high bandwidth for power supply control loop. 4. Cycle skipping operation at light load minimizes standby power consumption (typically <10 mA input current). 5. Line under-voltage ensures glitch free operations at both power-up and power-down and is tightly toleranced over process and temperature to meet system level requirements common in DC to DC converters (e.g. ETSI). 6. Line overvoltage protects DPA-Switch against excessive input voltage and line surge. 7. External current limit adjustment allows the setting of the current limit externally to a lower level near the operating peak current and, if desired, further adjusts the level gradually as line voltage rises. This makes possible an ideal implementation of overload power limiting. 8. Synchronization function allows the synchronization of DPA-Switch operation to an external lower frequency. 9. Remote ON/OFF feature permits DPA-Switch based power supplies to be easily switched on/off using logic signals. Maximum input current consumption is 2 mA in Remote OFF. 10. Hysteretic over-temperature shutdown provides automatic recovery from thermal fault. 11. Tight absolute tolerances and small temperature variations on switching frequency, current limit, and under-voltage lock out threshold (UV). 4 K 1/04 IB 75 Duty Cycle (%) DPA-Switch is an integrated switched mode power supply chip that converts a current at the control input to a duty cycle at the open drain output of a high voltage power MOSFET. During normal operation the duty cycle of the power MOSFET decreases linearly with increasing CONTROL pin current as shown in Figure 4. A patented high-voltage CMOS technology allows both the high-voltage power MOSFET and all the low voltage control circuitry to be cost effectively integrated onto a single monolithic chip. Auto-restart ICD1 Slope = PWM Gain 42 IL < IL(DC) 4 I C (SKIP) IL = 115 A IC (mA) PI-2761-112102 Figure 4. Relationship of Duty Cycle to CONTROL Pin Current. Three pins, LINE-SENSE (L), EXTERNAL CURRENT LIMIT (X) and FREQUENCY (F), are used to implement all the pin controllable features. A resistor from the LINE-SENSE pin to DC input bus implements line UV, line OV and line feed forward with DCMAX reduction. A resistor from the EXTERNAL CURRENT LIMIT pin to the SOURCE pin sets current limit externally. In addition, remote ON/OFF may be implemented through either the LINE-SENSE pin or the EXTERNAL CURRENT LIMIT pin depending on the polarity of the logic signal available as well as other system specific considerations. Shorting both the LINE-SENSE and the EXTERNAL CURRENT LIMIT pins to the SOURCE pin disables line OV, line UV, line feed forward with DCMAX reduction, external current limit, remote ON/OFF and synchronization. The FREQUENCY pin sets the switching frequency to 400 kHz if connected to the SOURCE pin, or 300 kHz if connected to the CONTROL pin. This pin should not be left open. Please refer to "Using Feature Pins" section for detailed information regarding the proper use of those pins. CONTROL Pin Operation The CONTROL pin is a low impedance node that is capable of receiving a combined supply and feedback current. During normal operation, a shunt regulator is used to separate the feedback signal from the supply current. CONTROL pin voltage VC is the supply voltage for the control circuitry including the MOSFET gate driver. An external bypass capacitor closely connected between the CONTROL and SOURCE pins is required to supply the instantaneous gate drive current. The total amount of capacitance connected to this pin also sets the auto-restart timing as well as control loop compensation. When the DC input voltage is applied to the DRAIN pin during start-up, the MOSFET is initially off, and the CONTROL pin capacitor is charged through the switched high voltage current source connected internally between the DRAIN and CONTROL pins. When the CONTROL pin voltage VC reaches DPA423-426 approximately 5.8 V, the control circuitry is activated and the soft-start begins. The soft-start circuit gradually increases the duty cycle of the MOSFET from zero to the maximum value over approximately 5 ms. The high voltage current source is turned off at the end of the soft-start. If no external feedback/ supply current is fed into the CONTROL pin by the end of the soft-start, the CONTROL pin will start discharging in response to the supply current drawn by the control circuitry and the gate current of the switching MOSFET driver. If the power supply is designed properly, and no fault condition such as open loop or overloaded output exists, the feedback loop will close, providing external CONTROL pin current, before the CONTROL pin voltage has had a chance to discharge to the lower threshold voltage of approximately 4.8 V (internal supply under-voltage lockout threshold). When the externally fed current charges the CONTROL pin to the shunt regulator voltage of 5.8 V, current in excess of the consumption of the chip is shunted to SOURCE through resistor RE as shown in Figure 2. This current flowing through RE controls the duty cycle of the power MOSFET to provide closed loop regulation. The shunt regulator has a finite low output impedance ZC that sets the gain of the error amplifier when used in a primary feedback configuration. The dynamic impedance ZC of the CONTROL pin together with the external CONTROL pin capacitance sets the dominant pole for the control loop. current standby mode. The high-voltage current source turns on and charges the external capacitance again. A hysteretic internal supply under-voltage comparator keeps VC within a window of typically 4.8 to 5.8 V by turning the high-voltage current source on and off as shown in Figure 5. The auto-restart circuit has a divide-by-8 counter that prevents the output MOSFET from turning on again until eight discharge/charge cycles have elapsed. This is accomplished by enabling the output MOSFET only when the divide-by-8 counter reaches full count (S7). The counter effectively limits DPA-Switch power dissipation as well as the maximum power delivered to the power supply output by reducing the auto-restart duty cycle to typically 4%. Auto-restart mode continues until output voltage regulation is again achieved through closure of the feedback loop. Oscillator and Switching Frequency The internal oscillator linearly charges and discharges an internal capacitance between two voltage levels to create a sawtooth waveform for the pulse width modulator. The oscillator sets both the pulse width modulator latch and the current limit latch at the beginning of each cycle. The nominal switching frequency of 400 kHz was chosen to minimize the transformer size and to allow faster power supply loop response. The FREQUENCY pin, when shorted to the CONTROL pin, lowers the switching frequency to 300 kHz, which may be preferable in some applications such as those employing secondary synchronous rectification. Otherwise, the FREQUENCY pin should be connected to the SOURCE pin for the default 400 kHz. When a fault condition such as an open loop or overloaded output prevents the flow of an external current into the CONTROL pin, the capacitor on the CONTROL pin discharges towards 4.8 V. At 4.8 V auto-restart is activated which turns the output MOSFET off and puts the control circuitry in a low ~ ~ ~ ~ VUV ~ ~ VLINE 0V S6 S7 S0 S1 S2 S6 S0 S7 S1 S2 ~ ~ S2 S6 S7 S7 5.8 V 4.8 V ~ ~ ~ ~ 0V S1 ~ ~ S0 ~ ~ S7 VC ~ ~ VDRAIN 0V VOUT 1 2 ~ ~ ~ ~ ~ ~ 0V 3 2 Note: S0 through S7 are the output states of the auto-restart counter 4 PI-2545-050602 Figure 5. Typical Waveforms for (1) Power Up (2) Normal Operation (3) Auto-restart (4) Power Down. K 1/04 5 DPA423-426 Pulse Width Modulator and Maximum Duty Cycle The pulse width modulator implements voltage mode control by driving the output MOSFET with a duty cycle inversely proportional to the current into the CONTROL pin that is in excess of the internal supply current of the chip (see Figure 4). The excess current is the feedback error signal that appears across RE (see Figure 2). This signal is filtered by an RC network with a typical corner frequency of 30 kHz to reduce the effect of switching noise in the chip supply current generated by the MOSFET gate driver. The filtered error signal is compared with the internal oscillator sawtooth waveform to generate the duty cycle waveform. As the control current increases, the duty cycle decreases. A clock signal from the oscillator sets a latch that turns on the output MOSFET. The pulse width modulator resets the latch, turning off the output MOSFET. Note that a minimum current must be driven into the CONTROL pin before the duty cycle begins to change. The maximum duty cycle, DCMAX is set at a default maximum value of 75% (typical). However, by connecting the LINE-SENSE to the DC input bus through a resistor with appropriate value, the maximum duty cycle can be made to decrease from 75% to 33% (typical) as shown in Figure 7 when input line voltage increases (see line feed forward with DCMAX reduction). Minimum Duty Cycle and Cycle Skipping To maintain power supply output regulation, the pulse width modulator reduces duty cycle as the load at the power supply output decreases. This reduction in duty cycle is proportional to the current flowing into the CONTROL pin. As the CONTROL pin current increases, the duty cycle reduces linearly towards a minimum value specified as minimum duty cycle, DCMIN. After reaching DCMIN, if CONTROL pin current is increased further by approximately 2 mA, the pulse width modulator will force the duty cycle from DCMIN to zero in a discrete step (refer to Figure 4). This feature allows a power supply to operate in a cycle skipping mode when the load consumes less power than the DPA-Switch delivers at minimum duty cycle, DCMIN. No additional control is needed for the transition between normal operation and cycle skipping. As the load increases or decreases, the power supply automatically switches between normal and cycle skipping mode as necessary. Cycle skipping may be avoided, if so desired, by connecting a minimum load at the power supply output such that the duty cycle remains at a level higher than DCMIN at all times. Error Amplifier The shunt regulator can also perform the function of an error amplifier in primary side feedback applications. The shunt regulator voltage is accurately derived from a temperaturecompensated bandgap reference. The gain of the error amplifier is set by the CONTROL pin dynamic impedance. The CONTROL pin clamps external circuit signals to the VC voltage 6 K 1/04 level. The CONTROL pin current in excess of the supply current is separated by the shunt regulator and flows through RE as a voltage error signal. On-chip Current Limit with External Programmability The cycle-by-cycle peak drain current limit circuit uses the output MOSFET ON-resistance as a sense resistor. A current limit comparator compares the output MOSFET on-state drain to source voltage, VDS(ON) with a threshold voltage. At the current limit, VDS(ON) exceeds the threshold voltage and the MOSFET is turned off until the start of the next clock cycle. The current limit comparator threshold voltage is temperature compensated to minimize the variation of the current limit due to temperature related changes in RDS(ON) of the output MOSFET. The default current limit of DPA-Switch is preset internally. However, with a resistor connected between EXTERNAL CURRENT LIMIT pin and SOURCE pin, the current limit can be programmed externally to a lower level between 25% and 100% of the default current limit. Please refer to the graphs in the Typical Performance Characteristics section for the selection of the resistor value. By setting current limit low, a larger DPA-Switch than necessary for the power required can be used to take advantage of the lower RDS(ON) for higher efficiency/ smaller heat sinking requirements. With a second resistor connected between the EXTERNAL CURRENT LIMIT pin and the DC input bus, the current limit is reduced with increasing line voltage, allowing a true power limiting operation against line variation to be implemented in a flyback configuration. The leading edge blanking circuit inhibits the current limit comparator for a short time after the output MOSFET is turned on. The leading edge blanking time has been set so that, if a power supply is designed properly, current spikes caused by primary-side capacitance and secondary-side rectifier reverse recovery time should not cause premature termination of the switching pulse. The current limit after the leading edge blanking time is as shown in Figure 31. To avoid triggering the current limit in normal operation, the drain current waveform should stay within the envelope shown. Line Under-Voltage Detection (UV) At power up, UV keeps DPA-Switch off until the input line voltage reaches the under voltage upper threshold. At power down, UV holds DPA-Switch on until the input voltage falls below the under voltage lower threshold. A single resistor connected from the LINE-SENSE pin to the DC input bus sets UV upper and lower thresholds. To avoid false triggering by noise, a hysteresis is implemented which sets the UV lower threshold typically at 94% of the UV upper threshold. If the UV lower threshold is reached during operation without the power supply losing regulation and the condition stays longer than 10 s (typical), the device will turn off and stay off until the UV upper threshold has been reached again. Then, a soft-start DPA423-426 will be initiated the next time CONTROL pin voltage reaches 5.8.V. If the power supply loses regulation before reaching the UV lower threshold, the device will enter auto-restart. At the end of each auto-restart cycle (S7), the UV comparator is enabled. If the UV upper threshold is not exceeded the MOSFET will be disabled during the next cycle (see Figure 5). The UV feature can be disabled independent of OV feature. DPA-Switch is not restricted by this feature under normal operation. Remote ON/OFF Remote ON/OFF control describes operation where the IC is turned on or off for long periods as opposed to the cycle-bycycle on/off control which is described in the Synchronization section below. Line Overvoltage Shutdown (OV) The same resistor used for UV also sets an over voltage threshold which, once exceeded, will force the DPA-Switch output into the off-state within one switching cycle. The ratio of OV and UV thresholds is preset at 2.7 as can be seen in Figure 7. When the MOSFET is off, the input voltage surge capability is increased to the voltage rating of the MOSFET (220 V), due to the absence of the reflected voltage and leakage spikes on the drain. A small amount of hysteresis is provided on the OV threshold to prevent noise triggering. The OV feature can be disabled independent of the UV feature as shown in Figure 13. DPA-Switch can be turned on or off by controlling the current into the LINE-SENSE pin or out from the EXTERNAL CURRENT LIMIT pin (see Figure 7). This allows easy implementation of remote ON/OFF control of DPA-Switch in several different ways. A transistor or an optocoupler output connected between the EXTERNAL CURRENT LIMIT pin and the SOURCE pin implements this function with "activeon" (Figures 17, 19 and 21) while a transistor or an optocoupler output connected between the LINE-SENSE pin and the CONTROL pin implements the function with "active-off" (Figures 18, 20 and 22). Line Feed Forward with DCMAX Reduction The same resistor used for UV and OV also implements line voltage feed forward that minimizes output line ripple and reduces power supply output sensitivity to line transients. This feed forward operation is illustrated in Figure 4 by the different values of IL. Note that for the same CONTROL pin current, higher line voltage results in smaller operating duty cycle. As an added feature, the maximum duty cycle DCMAX is also reduced from 75% (typical) at a voltage slightly higher than the UV threshold to 33% (typical) at the OV threshold (see Figures 4, 7). Limiting DCMAX at higher line voltages helps prevent transformer saturation due to large load transients in forward converter applications. DCMAX of 33% at the OV threshold was chosen to ensure that the power capability of the When a signal is received at the LINE-SENSE pin or the EXTERNAL CURRENT LIMIT pin to disable the output through any of the pin functions such as OV, UV and remote ON/OFF, DPA-Switch always completes its current switching cycle before the output is forced off. The internal oscillator is stopped at the end of the current cycle and stays there as long as the disable signal exists. When the signal at the above pins changes state from disable to enable, the internal oscillator starts the next switching cycle. The remote ON/OFF feature can be used as a standby or power switch to turn off the DPA-Switch and keep it in a very low power consumption state for indefinitely long periods. If the DPA-Switch is held in remote-off state for longer than 10 s fSYNC 128 kHz; tOFF 7.7 s; 120 ns tON 2250 ns for fOSC = 400 kHz 3080 ns for fOSC = 300 kHz Oscillator (SAW) DMAX VL 2V Time 0V tON tOFF ON OFF SYNC PI-2762-070501 Figure 6. Synchronization Timing Diagram. K 1/04 7 DPA423-426 (typical), the CONTROL pin goes into the hysteretic mode of operation. In this mode, the CONTROL pin goes through alternate charge and discharge cycles between 4.8 V and 5.8 V (see CONTROL Pin Operation section above) and the IC runs entirely off the high voltage DC input, but with very low power consumption (30 mW typical at 48 V with LINE-SENSE and EXTERNAL CURRENT LIMIT pins open). When the DPA-Switch is remotely turned on after entering this mode, it will initiate a normal start-up sequence with soft-start the next time the CONTROL pin reaches 5.8 V. In the worst case, the delay from remote on to start-up can be equal to the full discharge/charge cycle time of the CONTROL pin, which is approximately 36 ms for a 22 F CONTROL pin capacitor. This reduced-consumption remote-off mode can eliminate expensive and unreliable in-line mechanical switches. It also allows for microprocessor-controlled turn-on and turn-off sequences that may be required in certain applications. Synchronization In addition to sensing incoming current for OV, UV and remote ON/OFF, the LINE-SENSE pin also monitors its pin voltage through a 1 V threshold comparator. A pin voltage below 1 V turns on DPA-Switch. When the voltage at LINE-SENSE pin rises beyond 1 V to disable the output, DPA-Switch completes its current switching cycle before the output is forced off (similar to remote ON/OFF operation). The internal oscillator is stopped at the end of the current cycle awaiting the LINE-SENSE pin voltage to go low to start the next cycle. This allows the use of the 1 V threshold to synchronize DPA-Switch to an external signal with a frequency lower than its internal switching frequency. A transistor or an optocoupler output connected between the LINE-SENSE pin and the SOURCE pin implements this function (see Figure 24). Please refer to Figure 6 for the timing waveforms of synchronization operation. In order to be recognized as a synchronization pulse, the LINE-SENSE pin needs to stay low (on-time) for at least 120 ns but no more than 2250 ns for 400 kHz (or 3080 ns for 300 kHz) internal switching frequency. In addition, the off-time must be kept below 7.7 s which is a limitation set by the lowest synchronization frequency of 128 kHz allowed by the chip. The effective DCMAX for synchronization operation can be calculated as 0.75 x fSYNC/fOSC. An off-time longer than 7.7 s may force the CONTROL pin to go into the hysteretic mode and initiate a softstart cycle at next turn-on. Soft-Start Two on-chip soft-start functions are activated at start-up with a duration of 5 ms (typical). Maximum duty cycle starts from 0% and linearly increases to the default maximum of 75% at the end of the 5 ms duration and the current limit starts from about 85% and linearly increases to 100% at the end of the 5 ms duration. In addition to start-up, soft-start is also activated at each restart attempt during auto-restart and when restarting after being in 8 K 1/04 hysteretic regulation of CONTROL pin voltage (VC), due to remote off or thermal shutdown conditions. This effectively minimizes current and voltage stresses on the output MOSFET, the clamp circuit and the output rectifier during start-up. This feature also helps minimize output overshoot and prevents saturation of the transformer during start-up. Shutdown/Auto-Restart To minimize DPA-Switch power dissipation under fault conditions, the shutdown/auto-restart circuit turns the power supply on and off at an auto-restart duty cycle of typically 4% if an out of regulation condition persists. Loss of regulation interrupts the external current into the CONTROL pin. VC regulation changes from shunt mode to the hysteretic autorestart mode as described in CONTROL pin operation section. When the fault condition is removed, the power supply output becomes regulated, VC regulation returns to shunt mode, and normal operation of the power supply resumes. Hysteretic Over-Temperature Protection Over temperature protection is provided by a precision analog circuit that turns the output MOSFET off when the junction temperature exceeds the thermal shutdown temperature (137 C typical). When the junction temperature cools to below the hysteretic temperature (110 C typical), normal operation resumes providing automatic recovery. VC is regulated in hysteretic mode and a 4.8 V to 5.8 V (typical) sawtooth waveform is present on the CONTROL pin while in thermal shutdown. Bandgap Reference All critical DPA-Switch internal voltages are derived from a temperature-compensated bandgap reference. This reference is also used to generate a temperature-compensated current reference that is trimmed to accurately set the switching frequency, current limit, and the line OV/UV thresholds. DPA-Switch has improved circuitry to maintain all of the above critical parameters within very tight absolute and temperature tolerances. High-Voltage Bias Current Source This current source biases DPA-Switch from the DRAIN pin and charges the CONTROL pin external capacitance during start-up or hysteretic operation. Hysteretic operation occurs during auto-restart, remote off and over-temperature shutdown. In this mode of operation, the current source is switched on and off with an effective duty cycle of approximately 20%. This duty cycle is determined by the ratio of CONTROL pin charge (IC(CH)) and discharge currents (ICD1 and ICD2). This current source is turned off during normal operation when the output MOSFET is switching. The effect of the current source switching may be seen on the DRAIN voltage waveform as small disturbances which is normal. DPA423-426 SOURCE pin to generate synchronization pulse. Each time the MOSFET turns on, the falling edge of the LINE-SENSE pin voltage initiates a new switching cycle. The lowest synchronization frequency guaranteed by DPA-Switch is 128 kHz. Refer to Table 2 for possible combinations of the functions with example circuits shown in Figure 11 through Figure 24. A description of specific functions in terms of the LINE-SENSE pin I/V characteristic is shown in Figure 7 (right hand side). The horizontal axis represents LINE-SENSE pin current with positive polarity indicating currents flowing into the pin. The meaning of the vertical axes varies with functions. For those that control the on/off states of the output such as UV, OV and remote ON/OFF, the vertical axis represents the enable/ disable states of the output. UV triggers at IUV (+50 A typical with 4 A hysteresis) and OV triggers at IOV (+135 A typical with 4 A hysteresis). Between the UV and OV thresholds, the output is enabled. For line feed forward with DCMAX reduction, the vertical axis represents the magnitude of the DCMAX Line feed forward with DCMAX reduction lowers maximum duty cycle from 75% at IL(DC) (+55 A typical) to 33% at IOV (+135 A). Using Feature Pins FREQUENCY (F) Pin Operation The FREQUENCY pin is a digital input pin. Shorting the FREQUENCY pin to SOURCE pin selects the nominal switching frequency of 400 kHz (Figure 9) which is suited for most applications. For other applications that may benefit from lower switching frequency, a 300 kHz switching frequency can be selected by shorting the FREQUENCY pin to the CONTROL pin (Figure 10). This pin should not be left open. LINE-SENSE (L) Pin Operation When current is fed into the LINE-SENSE pin, it works as a voltage source of approximately 2.6 V up to a maximum current of +240 A (typical). At +240 A, this pin turns into a constant current sink. Refer to Figure 8. In addition, a comparator with a threshold of 1 V is connected at the pin and is used to detect when the pin is shorted to the SOURCE pin. There are a total of five functions available through the use of the LINE-SENSE pin: OV, UV, line feed forward with DCMAX reduction, remote ON/OFF and synchronization. Shorting the LINE-SENSE pin to the SOURCE pin disables all five functions. The LINE-SENSE pin is typically used for line sensing by connecting a resistor from this pin to the positive input DC voltage bus to implement OV, UV and line feed forward with DCMAX reduction over line voltage. In this mode, the value of the resistor determines the line OV/UV thresholds, and the DCMAX is reduced linearly with input DC high voltage starting from just above the UV threshold. This pin can also be used as the input pin for remote ON/OFF and synchronization. An external transistor placed between the LINE-SENSE pin and the CONTROL pin realizes remote on/off via UV or OV threshold. Synchronization is available by connecting an open drain external MOSFET between the LINE-SENSE pin and the EXTERNAL CURRENT LIMIT (X) Pin Operation When current is drawn out of the EXTERNAL CURRENT LIMIT pin, it works as a voltage source of approximately 1.3 V up to a maximum current of -230 A (typical). At -230 A, it turns into a constant current source (refer to Figure 8). There are two functions available through the use of the EXTERNAL CURRENT LIMIT pin: external current limit and remote ON/OFF. Shorting the EXTERNAL CURRENT LIMIT pin and SOURCE pin disables both functions. In high efficiency applications, this pin can be used to reduce the current limit externally to a value close to the operating peak current, by connecting the pin to the SOURCE pin through a resistor. The pin can also be used as a remote on/off control input. Table 2 LINE-SENSE AND EXTERNAL CURRENT LIMIT PIN TABLE* Figure Number 12 13 Under-Voltage Overvoltage Line Feed Forward (DCMAX) Three Terminal Operation 11 14 15 Remote ON/OFF 17 18 19 20 21 22 23 24 Overload Power Limiting External Current Limit 16 Synchronization *This table is only a partial list of many LINE-SENSE and EXTERNAL CURRENT LIMIT pin configurations that are possible. Table 2. Typical LINE-SENSE and EXTERNAL CURRENT LIMIT Pin Configurations. K 1/04 9 DPA423-426 IUV(U) IREM(U) (Enabled) IOV(U) (Enabled) Output MOSFET Switching Output MOSFET Switching (Disabled) (Disabled) ILIMIT (Default) DCMAX (75%) Current Limit Maximum Duty Cycle -21.5 A VBG + VTP -25.5 A VBG X Pin Voltage -250 L Pin Voltage -200 -150 -100 -50 0 0 X Pin Current (A) 131 A 135 A 47 A 50 100 150 200 250 L Pin Current (A) Note: These figures provide idealized functional characteristics with typical performance values. Please refer to the parametric table and typical performance characteristics sections of the data sheet for measured data. PI-2778-080801 Figure 7. LINE-SENSE and EXTERNAL CURRENT LIMIT Pin Characteristics. shows several different ways of using this pin. See Figure 7 for a description of the functions where the horizontal axis (left hand side) represents the EXTERNAL CURRENT LIMIT pin current. The meaning of the vertical axes varies with function. For those that control the on/off states of the output such as remote ON/OFF, the vertical axis represents the enable/disable 10 K 1/04 states of the output. For external current limit, the vertical axis represents the magnitude of the ILIMIT. Please see graphs in the Typical Performance Characteristics section for the current limit programming range and the selection of the appropriate resistor value. DPA423-426 CONTROL Pin DPA-Switch 230 A (Negative Current Sense - ON/OFF, Current Limit Adjustment) EXTERNAL CURRENT LIMIT (X) VBG + VT (Voltage Sense) LINE-SENSE (L) VBG 1V (Positive Current Sense - Under-Voltage, Overvoltage, ON/OFF Maximum Duty Cycle Reduction) 240 A PI-2765-080801 Figure 8. LINE-SENSE (L), and EXTERNAL CURRENT LIMIT (X) Pin Input Simplified Schematic. K 1/04 11 DPA423-426 Typical Uses of FREQUENCY (F) Pin + + DC Input Voltage DC Input Voltage D CONTROL C S F D CONTROL C S - F PI-2655-071700 PI-2654-071700 Figure 10. 300 kHz Frequency Operation. Figure 9. 400 kHz Frequency Operation. Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins + + VUV = IUV x RLS + VL (I = I ) L UV VOV = IOV x RLS + VL (I = I ) L C L X S F RLS D DC Input Voltage 619 k 1% DC Input Voltage L D C S For RLS = 619 k VUV = 33.3 V VOV = 86.0 V D D CONTROL L CONTROL C C S - X F - S PI-2766-070901 Figure 11. Three Terminal Operation (LINE-SENSE and EXTERNAL CURRENT LIMIT Features Disabled. FREQUENCY Pin can be tied to SOURCE or CONTROL Pin). + VUV = RLS x IUV + VL (I = I ) 576 k 1% L RLS DC Input Voltage PI-2767-091302 Figure 12. Line-Sensing for Under-Voltage, Overvoltage and Line Feed Forward. + 590 k 1% UV For Values Shown VUV = 33.3 V 42.2 k 1% D - 1N4148 L CONTROL C S - Figure 13. Line-Sensing for Under-Voltage Only (Overvoltage Disabled). K 1/04 OV 1% C PI-2852-091302 12 L 30 k D L VOV = IOV x RLS + VL (I = I ) For Values Shown VOV = 86.2 V RLS DC Input Voltage CONTROL 6.2 V OV S PI-2853-091302 Figure 14. Line-Sensing for Overvoltage Only (Under-Voltage Disabled). Maximum Duty Cycle will be reduced at Low Line. DPA423-426 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins (cont.) + For RIL = 12 k ILIMIT = 64% + ILIMIT = 100% @ 36 VDC ILIMIT = 64% @ 72 VDC RLS 363 k For RIL = 25 k ILIMIT = 34% DC Input Voltage See Figure 34 for other resistor values (RIL) D CONTROL C S DC Input Voltage D CONTROL C S X X RIL RIL 4.2 k - - PI-2854-050602 PI-2836-011904 Figure 15. Externally Set Current Limit. + Figure 16. Current Limit Reduction with Line Voltage. QR can be an optocoupler output or can be replaced by a manual switch. QR can be an optocoupler output or can be replaced by a manual switch. + QR ON/OFF RMC 47 k DC Input Voltage DC Input Voltage D CONTROL C 37.4 k L D CONTROL S C X ON/OFF QR 47 K - S PI-2625-040501 Figure 18. Active-off Remote ON/OFF. Maximum Duty Cycle will be reduced. Figure 17. Active-on (Fail Safe) Remote ON/OFF. + DC Input Voltage QR can be an optocoupler output or can be replaced by a MOSFET or manual switch. For RIL = 12 k ILIMIT = 64% D CONTROL C S For RIL = 25 k ILIMIT = 34% + ON/OFF 47 k RMC 47 k 37.4 k DC Input Voltage L D CONTROL C S QR QR can be an optocoupler output or can be replaced by a manual switch. QR ON/OFF X RIL - PI-2855-050602 For RIL = 12 k ILIMIT = 64% For RIL = 25 k ILIMIT = 34% X RIL - PI-2856-072602 PI-2857-050602 Figure 19. Active-on Remote ON/OFF with Externally Set Current Limit. Figure 20. Active-off Remote ON/OFF with Externally Set Current Limit. K 1/04 13 DPA423-426 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins (cont.) + DCMAX@36 V = 75% DCMAX@72 V = 42% CONTROL C S switch. QR For RIL = 12 k ILIMIT = 64% For RLS = 619 k ON/OFF QR can be an optocoupler output or can be replaced by a manual switch. L D 619 k output or can be replaced 1% by a MOSFET or manual RLS 619 k 1% RLS DC Input Voltage QR can be an optocoupler + 47 k DC Input Voltage VUV = 33.3 V VOV = 86.0 V L D CONTROL C X QR RIL ON/OFF - 47 k - S PI-2859-050602 Figure 21. Active-on Remote ON/OFF with LINE-SENSE and EXTERNAL CURRENT LIMIT. + For RLS = 619 k VUV = 33.3 V 619 K VOV = 86.0 V RLS DC Input Voltage - L DCMAX@36 V = 75% DCMAX@72 V = 42% CONTROL C K 1/04 + QR can be an optocoupler output. For timing requirements, see Figure 6. X RIL 12 k DC Input Voltage For RIL = 12 k ILIMIT = 64% See Figure 34 for other resistor values (RIL) to select different ILIMIT values PI-2837-011904 Figure 23. Line-Sensing and Externally Set Current Limit. 14 Figure 22. Active-off Remote ON/OFF with LINE-SENSE. 1% D S PI-2858-072602 D L CONTROL C S QR - ON/OFF 47 k PI-2640-050602 Figure 24. Synchronization. DPA423-426 Application Examples + VIN 36-75 VDC C7 1 nF 1.5 kV L1 1 H 2.5 A R14 10 R1 619 k 1% R15 10 R17 10 T1 R16 10 k CONTROL S VR1 SMBJ 150 X C R3 18.2 k 1% R4 1.0 C5 220 nF C4 4.7 F 20 V U2 PC357N1T U1 DPA425R F 5 V, 6 A D1 BAV 19WS RTN U2 R7 10 k R10 10.0 k 1% R5* DPA-Switch L D2 Q1 Si4888 DY D4 BAV19WS C9* D C12 1 F 10 V C11 100 F 10 V C17 3300 pF Q2 Si4888 DY C1, C2 & C3 1 F 100 V VIN C10 100 F 10 V L2 C6 68 F 10 V *Optional components D3 BAV19WS R6 150 C13 10 F 10 V U3 LM431AIM3 C16 100 nF R12 5.1 R9 220 C14 1 F R11 10.0 k 1% PI-3472-051303 Figure 25. A High Efficiency 30 W, 5 V, Telecom Input DC-DC Converter. High Efficiency 30 W Forward Converter The circuit shown in Figure 25 is a typical implementation of a single output DC-DC converter using DPA-Switch in a forward configuration with synchronous rectification. This design delivers 30 W at 5 V, from a 36 VDC to 75 VDC input with a nominal efficiency at 48 VDC of 90% using the DPA425R. By taking advantage of many of the built-in features of the DPA-Switch, the design is greatly simplified compared to a discrete implementation. Resistor R1 programs the input undervoltage and overvoltage thresholds to typically 33 V and 86 V respectively. This resistor also linearly reduces the maximum duty from the internal maximum of 75% at 36 V to 42% at 72 V to prevent core saturation during load transients at high input voltages. The DPA-Switch internal thresholds are toleranced and characterized so the designer can guarantee the converter will begin operation at 36 V, necessary to meet ETSI standards, without the cost of an external reference IC. The current limit is externally set by resistor R3 to just above the drain current level needed for maximum load regulation to limit the maximum overload power of the converter. The externally programmable current limit feature also allows a larger DPA-Switch family member to be selected. Using the X pin, the current limit can be adjusted to the same level. A large device reduces conduction losses and improves efficiency without requiring any other circuit changes. This has been used here to replace the DPA424R with a DPA425R. The selectable 300/400 kHz switching frequency is set to 300 kHz by connecting the FREQUENCY (F) pin to CONTROL (C). DRAIN voltage clamping is provided by VR1, which keeps the peak DRAIN voltage within acceptable limits. Transformer core reset is provided by the gate capacitance of Q1 with R17 in series. Optional reset capacitance C9 with R5 can be added if necessary to supplement the gate capacitance of Q1. The output of the transformer is rectified using MOSFETs to provide synchronous rectification. The UV/OV function, together with the turns ratio of the transformer, defines the maximum MOSFET gate voltage, allowing the very simple gate drive arrangement, without the need for drive windings or a drive IC. During primary on-time, capacitor C17 couples charge through resistor R15 to drive the gate of the forward MOSFET, Q2. Capacitor C17 provides a DC isolated drive for Q2, preventing gate overstress on Q1 during power down. The time constant formed by R16 and C17 is selected to be much longer than one switching cycle. Diode D4 resets the voltage on capacitor C17 before the next switching cycle. During the primary off-time, the diode D2 provides a conduction path for the energy in inductor L2 while Q1 is still off. The transformer K 1/04 15 DPA423-426 +VIN 36 - 57 VDC 1 T1 L1 1 H, 2A 9, 10 J1-1 R1 1 M 1% D2 SL43 R2 619 k 1% 2 3.3 V, 2 A J2-1 C5 330 F 6V C7 330 F 6V C6 330 F 6V C9 1 F 10 V RTN 6, 7 36 - 57 VDC 4 C2 47 pF 200 V J2-2 R5 100 3 D3 BAV19, SOD323 R6 51 5 C1 1 F 100 V VR1 SMAJ 150A L D CONTROL -VIN X F R3 8.66 k 1% C3 0.1 F 50 V R8 34 k 1% C8 1 F 50 V DPA-Switch U1 DPA423G U2 PC357 C S R7 1 k C11 0.1 F R4 5.1 C4 22 F 10 V J1-2 C10 0.33 F U3 CAT431L, SOT23 R9 20 k 1% PI-3806-012304 Figure 26. A Cost Effective 6.6 W, 3.3 V Flyback DC-DC Converter. reset voltage on the secondary winding directly drives a positive voltage on the gate of catch MOSFET, Q1. MOSFET Q1 provides a low loss conduction path for a substantial portion of the primary off-time. An isolated auxiliary winding on L2, rectified and filtered by D1 and C4, provides the bias supply for the optocoupler transistor.Output regulation is achieved by using secondary side voltage reference, U3. The resistor divider formed by R10 and R11, together with the reference voltage, determines the output voltage. Diode D3 and C13 form a softfinish network that, together with the internal duty cycle and current limit soft-start of the DPA-Switch, prevent output overshoot at start-up. Resistor R7 ensures that the soft-finish capacitor is discharged quickly when the output falls out of regulation.Control loop response is shaped by R6, C16, R12, C14, R9, R4 and C5, providing a wide bandwidth and good phase margin at gain crossover. Since the PWM control in DPA-Switch is voltage mode, no slope compensation is required for duty cycles above 50%. Cost Effective 6.6 W Flyback Conveter The DPA-Switch flyback power supply provides a cost effective solution for high density PoE and VoIP DC-DC applications. Figure 26 shows a typical implementation of a single output flyback converter using the DPA423G. For applications that require input to output isolation, this simple, low component count design delivers 6.6 W at 3.3 V from a 36 VDC to 57 VDC input with a nominal efficiency at 48 VDC of 80%. Resistor R2 programs the input under-voltage and overvoltage thresholds to 33 V and 86 V respectively. Resistors R1 and R3 16 K 1/04 program the internal device current limit. The addition of line sense resistor R1 reduces the current limit with increasing input voltage, preventing excessive overload output current. In this design the overload output current varies less than 2.5% across the entire input voltage range. Controlling the current limit also reduces secondary component stress and leakage inductance spikes, allowing the use of a lower VRRM (30 V rather than 40 V) Schottky output diode, D2. The primary side Zener clamp VR1 ensures the peak drain voltage is kept below the 220 V BVDSS rating of U1 under input surge and overvoltage events. During normal operation, VR1 does not conduct and C2 is sufficient to limit the peak drain voltage. The primary bias winding provides CONTROL pin current after start-up. Diode D3 rectifies the bias winding, while components R5 and C8 reduce high frequency switching noise and prevent peak charging of the bias voltage. Capacitor C3 provides local decoupling of U1 and should be physically close to the CONTROL and SOURCE pins. Energy storage for startup and auto-restart timing is provided by C4. The secondary is rectified by D2 and the Low ESR tantalum output capacitors, C5-C7, minimizing switching ripple and maximizing efficiency. A small footprint secondary output choke L1 and ceramic output capacitor C9 are adequate to reduce high frequency noise and ripple to below 35 mV peakpeak under full load conditions. The output voltage is sensed by the voltage divider formed by DPA423-426 resistors R8 and R9 and is fed to the low voltage 1.24 V reference U3. Feedback compensation is provided by R6, R7 and C11 together with C4 and R4. Capacitor C10 provides a soft-finish characteristic, preventing output overshoot during start-up. Key Application Considerations DPA-Switch Design Considerations Power Table This section provides a description of the assumptions used to generate the power tables (Tables 1 and 3 through 6) and explains how to use the information provided by them. All Power tables: Tables 1 and 3 through 6 * Maximum output power is limited by the device internal current limit. This is the peak output power which could become the continuous output power, provided adequate heat sinking is used. * Data assumes adequate heat sinking to keep the junction temperature at or below 100 C and worst case RDS(ON) at TJ = 100 C. * The use of P and G packages are recommended for device dissipation equal to or less than 1.5 W only due to package thermal limitation. For device dissipation above 1.5 W, use R package. Forward power tables: Tables 1 (upper half), 3 and 4 * Output power figures are based on forward topology using Schottky diode rectification. Up to 5% higher output power is possible using synchronous rectification. * Dissipation data assumes a diode loss representing 6% of the total output power and combined loss in magnetic components representing 6% of the total output power. DPA-Switch losses are based on a ratio between conduction and switching losses of approximately 3:1. These assumptions are typical for a single 5 V output forward converter design using Schottky rectification and adequately designed magnetic components. Flyback power tables: Tables 1 (lower half), 5 and 6 * Output power and dissipation figures are based on a 5 V output using Schottky diode rectification with an efficiency of 85%. Values are generated by calculation based on I2 * RDS(ON) losses and characterization of switching losses, correlated to bench measurement of each DPA-Switch device. * Device dissipations above 1.5 W are possible using the R package. However the forward converter topology is recommended for such higher power designs. The power tables provide two types of information. The first is the expected device dissipation for a given output power. The second is the maximum power output. Each table specifies the input voltage range and assumes a single 5 V output using Schottky diode rectification. OUTPUT POWER TABLE 16-32 VDC RANGE (FORWARD)2 Total Device Dissipation 0.5 W PRODUCT3 1W 2.5 W 4 W Max Power Output1 6W 5W 7W 7 W 10 W 15 W 10 W 14 W 22 W 27 W 12 W 16.5 W 25 W 31 W 37 W DPA423 DPA424 DPA425 DPA426 7.5 W 15.5 W 31 W 43 W Table 3. Output Power Table for 16 VDC Minimum Input Voltage. Notes: 1. Maximum output power is limited by device internal current limit. 2. See text in this section for a complete description of assumptions. 3. See Part Ordering Information. OUTPUT POWER TABLE 24-48 VDC RANGE (FORWARD)2 Total Device Dissipation 0.5 W PRODUCT3 8W 11 W 16 W 18 W DPA423 DPA424 DPA425 DPA426 1W 2.5 W 4W 6W Max Power Output1 11 W - 11.5 W 16 W 23.5 W 25 W 22 W 35 W 43 W 47 W 25 W 39 W 48 W 58 W 65 W Table 4. Output Power Table for 24 VDC Minimum Input Voltage (See Table 3 for Notes). OUTPUT POWER TABLE 16-32 VDC RANGE (FLYBACK)2 Total Device Dissipation 0.5 W 0.75 W 1W 1.5 W Max Power Output1 15 W 6W 11 W 22 W PRODUCT3 DPA423 DPA424 DPA425 5W 6.5 W 7W 8.5 W 10 W 10 W 12 W Table 5. Flyback Output Power Table for 16 VDC Minimum Input Voltage (See Table 3 for Notes). For example, referring to Table 1, for 36-75 VDC input range, DPA424 would typically dissipate 1 W in a 23 W forward converter and has a maximum power capacity of 35 W. In the same converter, DPA425 would dissipate 0.5 W. Selecting DPA425 with associated reduced dissipation would increase overall converter efficiency by approximately 2%. Issues Affecting Dissipation: 1) Using synchronous rectification will tend to reduce device dissipation. K 1/04 17 DPA423-426 OUTPUT POWER TABLE 24-48 VDC RANGE (FLYBACK)2 Total Device Dissipation 0.5 W 0.75 W 1W 1.5 W Max Power Output1 - 8.5 W 17 W 34 W PRODUCT3 DPA423 DPA424 DPA425 7W 8.5 W 11.5 W 14 W -4 -4 -4 Table 6. Flyback Output Power Table for 24 VDC Minimum Input Voltage. Notes: 1. Maximum output power is limited by device internal current limit. 2. See text in this section for a complete description of assumptions. 3. See Part Ordering Information. 4. Due to higher switching losses, the DPA425 may not deliver additional power compared to a smaller device. 2) Designs with lower output voltages and higher currents will tend to increase the device dissipation listed in the power table. 3) Reduced input voltage decreases the available output power for the same device dissipation. Tables 3 to 6 are the power tables for 16 VDC and 24 VDC input voltages. Input voltages below 16 V are possible, but since the internal start-up current source is not specified at voltages below 16 V, an external chip supply current should be fed into the CONTROL pin approximately equal to but less than ICD1. DPA-Switch Selection Use Tables 1 and 3 through 6 to select the DPA-Switch based on device dissipation. Selecting the optimum DPA-Switch depends upon required maximum output power, efficiency, heat sinking constraints and cost goals. With the option to externally reduce current limit, a larger DPA-Switch may be used for lower power applications where higher efficiency is needed or minimal heat sinking is available. Generally, selecting the next larger device, than is required for power delivery will give the highest efficiency. Selecting even larger devices may give little or no improvement in efficiency due to the improvement in conduction losses being negated by larger device switching losses. Figure 50 provides information on switching losses. This together with conduction loss calculations give an estimate of device dissipation. Primary Clamp A primary clamp network is recommended to keep the peak DRAIN voltage due to primary leakage inductance to below the BVDSS specification. A Zener diode combined with a small value capacitor connected across the primary winding is a low cost and low part count implementation. Output Rectification Rectification of the secondary is typically performed using Schottky diodes or synchronous rectification. Schottky diodes are selected for peak inverse voltage, output current, forward drop and thermal 18 K 1/04 conditions. Synchronous rectification requires the additional complication of providing gate drive. The specified line undervoltage and line overvoltage thresholds of DPA-Switch simplifies deriving gate drive directly from the transformer secondary winding for many applications. The turns ratio of the transformer together with the under/over-voltage thresholds defines the minimum and maximum gate voltages, removing the need for Zeners to clamp the gate voltage. Soft-Start Generally a power supply experiences maximum stress at start-up before the feedback loop achieves regulation. For a period of 5 ms the on-chip soft-start linearly increases the duty cycle from zero to the default DCMAX at turn-on. In addition, the primary current limit increases from 85% to 100% over the same period. This causes the output voltage to rise in an orderly manner allowing time for the feedback loop to take control of the duty cycle. This integrated soft-start reduces the stress on the DPA-Switch MOSFET, clamp circuit and output diode(s), and helps prevent transformer saturation during start-up. Also, soft-start limits the amount of output voltage overshoot, and in many applications eliminates the need for a soft-finish capacitor. If necessary, to remove output overshoot, a soft-finish capacitor may be added to the secondary reference. Switching Frequency The FREQUENCY pin of DPA-Switch offers a switching frequency option of 400 kHz or 300 kHz. Operating at 300 kHz will increase the amount of magnetization energy stored in the transformer. This is ideal for applications using synchronous rectification driven directly from the transformer secondary where this energy can be used to drive the catch MOSFET gate. Transformer Design It is recommended that the forward converter transformer be designed for maximum operating flux swing of 1500 Gauss and a peak flux density of 3500 Gauss. When operating at the maximum current limit of the selected DPA-Switch (during overload conditions), neither magnetic component (transformer and output inductor) should be allowed to saturate. When a larger device than necessary has been selected, reducing the internal current limit close to the operating peak current limits overload power and minimizes the size of the secondary components. No-load and Standby Consumption Cycle skipping operation at light or no load can significantly reduce power loss. In addition this operating mode ensures that the output maintains regulation even without an external minimum load. However, if cycle skipping is undesirable in a particular application, it can be avoided by adding sufficient pre-load. DPA-Switch Layout Considerations The DPA-Switch can operate with large DRAIN current, the following guidelines should be carefully followed. DPA423-426 Primary Side Connections The tab of DPA-Switch R package is the intended return path for the high switching currents. Therefore, the tab should be connected by wide, low impedance traces back to the input decoupling capacitor. The SOURCE pin should not be used to return the power currents; incorrect operation of the device may result. The SOURCE is only intended as a signal ground. The device tab (SOURCE) is the correct connection for power currents with the R package. The CONTROL pin bypass capacitor should be located as close as possible to the SOURCE and CONTROL pins and its SOURCE connection trace should not be shared by the main MOSFET switching currents. All SOURCE pin referenced components connected to the LINE-SENSE or EXTERNAL CURRENT LIMIT pins should also be located closely between their respective pin and SOURCE. Once again, the SOURCE connection trace of these components should not be shared by the main MOSFET switching currents. It is critical that the tab (SOURCE) power switching currents are returned to the input capacitor through a separate trace that is not shared by the components connected to CONTROL, LINE-SENSE or EXTERNAL CURRENT LIMIT pins. Any traces to the L or X pins should be kept as short as possible and away from the DRAIN trace to prevent noise coupling. LINE-SENSE resistor (R1 in Figure 25) should be located close to the L pin to minimize the trace length on the L pin side. In addition to the CONTROL pin capacitor (C6 in Figure 25), a high frequency bypass capacitor in parallel is recommended as close as possible between SOURCE and CONTROL pins for better noise immunity. The feedback optocoupler output should also be located close to the CONTROL and SOURCE pins of DPA-Switch. Heat Sinking To maximize heat sinking of the DPA-Switch R or G package and the other power components, special thermally conductive PC board material (aluminum clad PC board) is recommended. This has an aluminum sheet bonded to the PC board during the manufacturing process to provide heat sinking directly and allow the attachment of an external heat sink. If normal PC board material is used (such as FR4), providing copper areas on both sides of the board and using thicker copper will improve heat sinking. If an aluminum clad board is used then shielding of switching nodes is recommended. This consists of an area of copper placed directly underneath switching nodes such as the drain node, and output diode to provide an electrostatic shield to prevent coupling to the aluminum substrate. These areas are connected to input negative in the case of the primary and output return for secondary. This reduces the amount of capacitive coupling into the insulated aluminum substrate that can then appear on the output as ripple and high frequency noise. Quick Design Checklist As with any power supply design, all DPA-Switch designs should be verified on the bench to make sure that component specifications limits are not exceeded under worst case conditions. The following minimum set of tests for DPA-Switch forward converters is strongly recommended: 1. Maximum drain voltage - Verify that peak VDS does not exceed minimum BVDSS at highest input voltage and maximum overload output power. It is normal, however, to have additional margin of approximately 25 V below BVDSS to allow for other power supply component unit-to-unit variations. Maximum overload output power occurs when the output is loaded to a level just before the power supply goes into auto-restart (loss of regulation). 2. Transformer reset margin - Drain voltage should also be checked at highest input voltage with a severe load step (50100%) to verify adequate transformer reset margin. This test shows the duty cycle at high input voltage, placing the most demand on the transformer reset circuit. 3. Maximum drain current - At maximum ambient temperature, maximum input voltage and maximum output load, verify drain current waveforms at start-up for any signs of transformer or output inductor saturation and excessive leading edge current spikes. DPA-Switch has a leading edge blanking time of 100 ns to prevent premature termination of the on cycle. Verify that the leading edge current spike does not extend beyond the blanking period. 4. Thermal check - At maximum output power, minimum input voltage and maximum ambient temperature, verify that temperature specifications are not exceeded for the transformer, output diodes, output choke(s) and output capacitors. The DPA-Switch is fully protected against overtemperature conditions by its thermal shutdown feature. It is recommended that sufficient heat sinking is provided to keep the tab temperature at or below 115 C (R package), SOURCE pins at or below 100 C (P/G packages) under worst case continuous load conditions (at low input voltage, maximum ambient and full load). This provides adequate margin to minimum thermal shutdown temperature (130 C) to account for part-to-part RDS(ON) variation. When monitoring device temperatures, note that the junction-tocase thermal resistance should be accounted for when estimating die temperature. Design Tools Up-to-date information on design tools is available at the Power Integrations Web site: www.powerint.com. K 1/04 19 DPA423-426 Solder Side Component Side TOP VIEW Output Diode V Transformer + D Inductor (Coupled) V DC In S DPA-Switch X L C V + DC Out Optocoupler - - V Maximize hatched copper area for optimum heat sinking V Via between board layers PI-2883-060602 Figure 27. Layout Considerations for DPA-Switch Using R Package. Top Side PCB Bottom Side PCB TOP VIEW Bottom Diode Heatsink (Two sided printed circuit board) V V + V DC In V - - S S D S V DPA-Switch C L X F T r a n s f o r m e r V V V + DC Out V V V PI-3805-012904 DPA-Switch Heatsink V Optocoupler Maximize hatched copper area for optimum heat sinking V Via between board layers Figure 28. Layout Considerations for DPA-Switch Using G Package. 20 K 1/04 DPA423-426 ABSOLUTE MAXIMUM RATINGS(1, 4) DRAIN Voltage ............................................ -0.3 to 220 V DRAIN Peak Current: DPA423 ............................... 1.75 A DPA424 ................................. 3.5 A DPA425 .................................... 7 A DPA426 ................................. 9.6 A CONTROL Voltage .......................................... -0.3 to 9 V CONTROL Current ............................................... 100 mA LINE SENSE Pin Voltage ................................ -0.3 to 9 V EXTERNAL CURRENT LIMIT Pin Voltage .. -0.3 to 9 V FREQUENCY Pin Voltage ............................... -0.3 to 9 V Storage Temperature ..................................... -65 to 150 C Operating Junction Temperature (2) ............... -40 to 150 C Lead Temperature (3) ............................................... 260 C Notes: 1. All voltages referenced to SOURCE, TA = 25 C. 2. Normally limited by internal circuitry. 3. 1/16" from case for 5 seconds. 4. Maximum ratings specified may be applied, one at a time, without causing permanent damage to the product. Exposure to Absolute Maximum Rating conditions for extended periods of time may affect product reliability. THERMAL IMPEDANCE Thermal Impedance: P or G Package: (JA) ...................... 70 C/W(1); 60 C/W(2) (JC)(3) ......................................... 11 C/W R Package: (JA) ......................................... 40 C/W(4) ............................................................................ 30 C/W(5) (JC)(6) ........................................... 2 C/W Notes: 1. Soldered to 0.36 sq. in. (232 mm2), 2 oz. (610 g/m2) copper clad. 2. Soldered to 1 sq. in (645 mm2), 2 oz. (610 g/m2) copper clad. 3. Measured on pin 7 (SOURCE) close to plastic interface. 4. Soldered to 1 sq. inch (645 mm2), 2 oz. (610 g/m2) copper clad. 5. Soldered to 3 sq. inch (1935 mm2), 2 oz. (610 g/m2) copper clad. 6. Measured at the back surface of tab. Conditions Parameter Symbol (Unless Otherwise Specified) See Figure 32 SOURCE = 0 V; TJ = -40 to 125 C Min Typ Max 375 400 425 282 300 317 4 6 Units CONTROL FUNCTIONS Switching Frequency Duty Cycle (Prior to Cycle Skipping) Maximum Duty Cycle Control Current at Start of Cycle Skipping External Bias Current fOSC TJ = 25 C FREQUENCY Pin Connected to SOURCE FREQUENCY Pin Connected to CONTROL kHz DCMIN DCMAX IC(skip) IB IC = ICD1 VL = 0 V 71 75 79 IL = 80 A 52 62 71 IL = 115 A 32 42 57 DPA423 7.2 9.0 DPA424 8.2 10.0 DPA425 10.0 11.5 12.0 14.0 2 2.5 2.8 3.5 3.5 4.4 3.6 4.8 6.0 4.4 5.7 7.1 TJ = 25 C; fOSC = 400 kHz TJ = 25 C; fOSC = 400 kHz DPA426 DPA423 DPA424 DPA425 DPA426 % % mA mA K 1/04 21 DPA423-426 Conditions Parameter Symbol (Unless Otherwise Specified) See Figure 32 SOURCE = 0 V; TJ = -40 to 125 C Min Typ Max Units 5 7.2 ms -22 -18 %/mA CONTROL FUNCTIONS (cont.) Softstart Time PWM Gain tSOFT TJ = 25 C; DCMIN to DCMAX DCreg TJ = 25 C; IC = (IC(skip) + IB)/2 PWM Gain Temperature Drift Dynamic Impedance -28 TJ = 25 C; IC = (IC(skip) + IB)/2 ZC %/mA/C -0.01 See Note A 10 Dynamic Impedance Temperature Drift CONTROL Pin Internal Filter Pole 15 22 0.18 %/C 30 kHz SHUTDOWN/AUTO-RESTART CONTROL Pin Charging Current IC(CH) During Startup and Auto-Restart: VC=5.0 V; VD=16 V & 40 V; TJ=25 C -5.2 -4 mA Average Current at the Beginning of Softstart: VC=5.0 V; VD=16 V & 40 V; TJ=25 C -19 See Note A -0.6 %/C 5.8 V Charging Current Temperature Drift Auto-restart Upper Threshold Voltage VC (AR)U Auto-restart Lower Threshold Voltage VC (AR)L 4.5 4.8 Auto-restart Hysteresis Voltage VC(AR)Hyst 0.8 1 Auto-restart Duty Cycle Auto-restart Frequency -3 DC(AR) CCONTROL = 22 F; fOSC = 400 kHz; VX = 0 V f(AR) CCONTROL = 22 F; fOSC = 400 kHz; VX = 0 V 5.1 V V 10 % Hz 3.8 LINE-SENSE (L) AND EXTERNAL CURRENT LIMIT (X) INPUTS Line UnderVoltage Threshold Current and Hysteresis (L pin) 22 K 1/04 IUV TJ = 25 C Threshold from Off to On 48 50 52 Threshold from On to Off 44.5 47 49.5 Hysteresis 2 3 A DPA423-426 Conditions Parameter Symbol (Unless Otherwise Specified) See Figure 32 SOURCE = 0 V; TJ = -40 to 125 C Min Typ Max Units LINE-SENSE (L) AND EXTERNAL CURRENT LIMIT (X) INPUTS (cont) Line Overvoltage or Remote ON/ OFF Threshold Current and Hysteresis (L pin) Threshold from On to Off IOV Threshold from On to Off IREM L pin Short Circuit Current IL(SC) X pin Short Circuit Current IX(SC) L pin Voltage (Positive Current) VL Maximum Duty Cycle Reduction Onset Threshold Current Remote OFF DRAIN Supply Current L pin Voltage Turn-On Threshold in Synchronous Mode ID(RMT) Off-Time Pulse Width for Synchronization toff(sync) tdelay(sync) -21.5 4.5 VD = 40 V VX = 0 V -16 A VL = VC 175 240 VL = 0 V -230 -170 Normal Mode -270 -230 -185 Remote OFF using L Pin -105 -85 -65 IL = IUV 2.05 2.35 2.6 IL = IOV 2.1 2.5 2.9 IX = -50 A 1.35 IX = -150 A 1.25 TJ = 25 C 55 380 A A V A VL= Floating 0.6 1.1 VL=VC 0.9 1.5 1 1.4 mA 0.6 VL(TH) ton(sync) -27 Hysteresis IL(DC) A 4 -25.5 VX = 0 V 149 131 TJ = 25 C Threshold from Off to On VX On-Time Pulse Width for Synchronization Synchronous Turn On Delay 117 Hysteresis Remote ON/OFF Negative Threshold Current and Hysteresis (X pin) X pin Voltage (Negative Current) TJ = 25 C Threshold from Off to On 135 V fOSC = 400 kHz 120 2250 fOSC = 300 kHz 120 3080 0.25 7.7 s 250 ns From Synchronous On to Drain Turn-On ns K 1/04 23 DPA423-426 Conditions Parameter Symbol (Unless Otherwise Specified) See Figure 32 SOURCE = 0 V; TJ = -40 to 125 C Min Typ Max Units 4 V FREQUENCY (F) INPUT FREQUENCY Pin Threshold Voltage VF FREQUENCY Pin Input Current IF FREQUENCY Pin Delay Time tdelay(VF) 1.1 VF = 0 V -0.38 VF = VC 17 A 120 2 s CIRCUIT PROTECTION Self Protection Current Limit (See Note B) ILIMIT TJ = 25 C DPA423 di/dt = 300 mA/s 1.16 1.25 1.34 DPA424 di/dt = 600 mA/s 2.32 2.50 2.68 DPA425 di/dt = 1.25 A/s 4.65 5.00 5.35 DPA426 di/dt = 1.75 A/s 6.50 7.00 7.50 Initial Current Limit IINIT VD = 35 V Leading Edge Blanking Time tLEB TJ = 25 C Current Limit Delay tIL(D) IC = (IC(skip) +IB)/2 Thermal Shutdown Temperature TJ(SD) Thermal Shutdown Hysteresis TJ(SD)hyst Power-up Reset Threshold Voltage VC(RESET) A 0.9 x ILIMIT(min) A 100 100 130 137 ns 145 27 1.5 ns C C 2.75 4 1.30 2.00 1.50 2.30 0.65 0.75 1.00 0.33 0.50 0.24 0.37 1.15 0.38 0.58 0.28 0.43 V OUTPUT ON-State Resistance RDS(ON) TJ = 100 C DPA424 ID = 600 mA TJ = 25 C TJ = 100 C DPA425 ID = 1.25 A TJ = 25 C TJ = 100 C TJ = 25 C TJ = 100 C DPA426 ID = 1.75 A 24 K 1/04 TJ = 25 C DPA423 ID = 300 mA DPA423-426 Conditions Parameter Symbol (Unless Otherwise Specified) See Figure 32 SOURCE = 0 V; TJ = -40 to 125 C Min Typ Max Units 65 130 260 360 A OUTPUT (cont) OFF-State Drain Leakage Current Breakdown Voltage IDSS BVDSS DPA423 DPA424 DPA425 DPA426 VX, VL = Floating; VD = 150 V; TJ = 125 C; IC = (IC(skip) + IB)/2 VX, VL = Floating; TJ = 25 C IC = (IC(skip) + IB)/2; See Note C 220 V Rise Time tR Measured in a Typical Application 10 ns Fall Time tF Measured in a Typical Application 10 ns SUPPLY VOLTAGE CHARACTERISTICS DRAIN Supply Voltage Shunt Regulator Voltage VC(SHUNT) Shunt Regulator Temperature Drift CONTROL Supply/Discharge Current See Note D 16 IC = (IC(skip) + IB)/2; TJ = 25 C 5.6 IC = (IC(skip) + IB)/2 lCD1 lCD2 Output MOSFET Enabled VL = 0 V; fOSC = 400 kHz DPA423 DPA424 DPA425 DPA426 Output MOSFET Disabled VL = 0 V; fOSC = 400 kHz V 5.85 6.0 50 V PPM/C 1.9 2.6 3.7 4.8 2.3 3.0 4.3 5.4 2.7 3.4 4.8 6 0.4 0.73 1.2 mA NOTES: A. For specifications with negative values, a negative temperature coefficient corresponds to an increase in magnitude with increasing temperature, and a positive temperature coefficient corresponds to a decrease in magnitude with increasing temperature. B. For externally adjusted current limit values, please refer to Figure 34 (Current Limit vs. External Current Limit Resistance) in the Typical Performance Characteristics section. C. Breakdown voltage may be checked against minimum BVDSS specification by ramping the DRAIN pin voltage up to but not exceeding minimum BVDSS. D. It is possible to start up and operate DPA-Switch at DRAIN voltages well below 16 V. However, the CONTROL pin charging current is reduced, which affects start-up time, auto-restart frequency, and auto-restart duty cycle. Refer to Figure 44, the characteristic graph on CONTROL pin charge current (IC) vs. DRAIN voltage for low voltage operation characteristics. K 1/04 25 DPA423-426 t2 t1 HV 90% 90% DRAIN VOLTAGE t D= 1 t2 10% 0V PI-2039-033001 100 80 60 40 Dynamic 1 = Impedance Slope 20 1.4 DRAIN Current (Normalized) PI-2880-060302 CONTROL Pin Current (mA) 120 PI-2889-061302 Figure 29. Duty Cycle Measurement. tLEB (Blanking Time) + tIL(D) (Current Limit Delay) 1.2 1 0.8 0.6 0.4 Temperature Range: -40 C to 125 C 0.2 0 0 0 2 4 6 8 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 10 Time (s) CONTROL Pin Voltage (V) Figure 30. CONTROL Pin I-V Characteristic. S1 Figure 31. Typical Drain Operation Current Envelope. 470 5W 0-200 k 5-50 V 40 V L 470 D CONTROL C C DPA-Switch S2 S4 0-15 V 47 F 0.1 F F X S S3 0-70 k NOTE: This test circuit is not applicable for current limit or output characteristic measurements. PI-2860-050602 Figure 32. DPA-Switch General Test Circuit. 26 K 1/04 DPA423-426 BENCH TEST PRECAUTIONS FOR EVALUATION OF ELECTRICAL CHARACTERISTICS The following precautions should be followed when testing DPA-Switch by itself outside of a power supply. The schematic shown in Figure 32 is suggested for laboratory testing of DPA-Switch. restart mode, there is only a 12.5% chance that the CONTROL pin oscillation will be in the correct state (drain active state) so that the continuous drain voltage waveform may be observed. It is recommended that the VC power supply be turned on first and the DRAIN pin power supply second if continuous drain voltage waveforms are to be observed. The 12.5% chance of being in the correct state is due to the divide-by-8 counter. Temporarily shorting the CONTROL pin to the SOURCE pin will reset DPA-Switch, which then will come up in the correct state. When the DRAIN pin supply is turned on, the part will be in the auto-restart mode. The CONTROL pin voltage will be oscillating at a low frequency between 4.8 and 5.8 V and the drain is turned on every eighth cycle of the CONTROL pin oscillation. If the CONTROL pin power supply is turned on while in this auto- 1.1 PI-2838-032202 Current Limit (Normalized to Internal Current Limit) Typical Performance Characteristics 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 -230 -180 -130 -80 -30 0 IX (A) 1.1 PI-2839-032202 Current Limit (Normalized to Internal Current Limit) Figure 33. Current Limit vs. EXTERNAL CURRENT LIMIT Pin Current. 1.0 0.9 Maximum 0.8 0.7 Minimum 0.6 0.5 Typical 0.4 0.3 0.2 0.1 0 5 10 15 20 25 30 35 External Current Limit Resistor RIL (k) Figure 34. Current Limit vs. External Current Limit Resistance. K 1/04 27 DPA423-426 Typical Performance Characteristics (cont.) 0.8 0.6 0.4 0.2 PI-2866-051702 1.0 1.2 Current Limit (Normalized to 25 C) PI-2868-051502 1.0 0.8 0.6 0.4 0.2 0 0 25 50 0 75 100 125 150 -50 -25 Junction Temperature (C) 0.8 0.6 0.4 0.2 1.0 0.8 0.6 0.4 0.2 0 0 25 50 -50 -25 75 100 125 150 PI-2867-051502 Under-Voltage Threshold (Normalized to 25 C) 1.0 0.8 0.6 0.4 0.2 0 0 25 50 25 50 75 100 125 150 75 100 125 150 Junction Temperature (C) Figure 39. Under-Voltage Threshold vs. Temperature. Figure 38. Overvoltage Threshold vs. Temperature. 7.0 LINE-SENSE Pin Voltage (V) Figure 37. External Current Limit vs. Temperature with RIL =12 k. 1.2 0 Junction Temperature (C) Junction Temperature (C) K 1/04 75 100 125 150 1.2 Overvoltage Threshold (Normalized to 25 C) PI-2872-051602 Current Limit (Normalized to 25 C) 1.0 28 50 Figure 36. Internal Current Limit vs. Temperature. 1.2 -50 -25 25 Junction Temperature (C) Figure 35. Frequency vs. Temperature. 0 -50 -25 0 PI-2865-051702 -50 -25 PI-2871-051502 Output Frequency (Normalized to 25 C) 1.2 6.0 5.0 4.0 3.0 2.0 1.0 0.0 -200 -150 -100 -50 0 50 100 150 200 250 LINE-SENSE Pin Current (A) Figure 40. LINE-SENSE Pin Voltage vs. Current. DPA423-426 -200 A IX -25 A 1.2 1.0 0.8 0.6 0.4 1.2 0.2 PI-2863-011904 1.4 VX = 1.375 - IXx 843 k CONTROL Pin Current (Normalized to 25 C) EXTERNAL CURRENT LIMIT Pin Voltage (V) 1.6 PI-2869-051502 Typical Performance Characteristics (cont.) 1.0 0.8 0.6 0.4 0.2 0 0 -225 -175 -125 -75 -25 -250 -200 -150 -100 -50 0 -50 -25 0 25 50 75 100 125 150 Junction Temperature (C) Figure 41. EXTERNAL CURRENT LIMIT Pin Voltage vs. Current. Figure 42. CONTROL Pin Current at Minimum Duty Cycle vs. Temperature. 1.0 0.8 0.6 0.4 0.2 5.0 VC = 5 V 4.5 CONTROL Pin Charging Current (mA) PI-2864-051702 Onset Threshold Current (Normalized to 25 C) 1.2 PI-2841-051502 EXTERNAL CURRENT LIMIT Pin Current (A) 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 -50 -25 0 25 50 0.0 75 100 125 150 0 10 Junction Temperature (C) 40 50 60 0.8 0.6 0.4 Figure 44. IC vs. DRAIN Voltage. PI-176B-033001 1.1 Breakdown Voltage (Normalized to 25 C) PI-2870-051502 Remote OFF DRAIN Supply Current (Normalized to 25 C) 1.0 30 DRAIN Voltage (V) Figure 43. Max. Duty Cycle Reduction Onset Threshold Current vs. Temperature. 1.2 20 1.0 0.2 0 -50 -20 0.9 0 25 50 75 100 125 150 Junction Temperature (C) Figure 45. Remote OFF DRAIN Supply Current vs. Temperature. -50 -25 0 25 50 75 100 125 150 Junction Temperature (C) Figure 46 Breakdown Voltage vs. Temperature. K 1/04 29 DPA423-426 Typical Performance Characteristics (cont.) Drain Current (A) 16 14 TCASE = 25 C 12 10 8 TCASE = 100 C 6 4 2.5 PI-2850-011904 Scaling Factors: DPA423 = 0.18 DPA424 = 0.36 DPA425 = 0.72 DPA426 = 1.00 On-resistance (Normalized to 25 C) 18 PI-2849-050302 20 2 1.5 1 0.5 2 0 0 1 2 3 4 -50 -25 5 Figure 47 Output Characteristics. PI-2851-011904 Scaling Factors: DPA423 = 0.18 DPA424 = 0.36 DPA425 = 0.72 DPA426 = 1.00 1000 100 10 0 20 40 60 80 100 120 140 160 DRAIN Voltage (V) Figure 49. COSS vs. DRAIN Voltage. 30 K 1/04 25 50 75 100 125 150 Figure 48. On-resistance vs. Temperature. Switching Loss (Watts) at 400 kHz Capacitance (pF) 10000 0 Temperature (C) Drain Voltage (V) 2.5 2 PI-2877-052802 0 Data taken from a typical forward converter design. 1.5 1 Scaling Factors: DPA423 = 0.08 DPA424 = 0.20 DPA425 = 0.55 DPA426 = 1.00 0.5 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 In-Circuit Peak Drain Current Normalized to Nominal Device Internal Current Limit Figure 50. Typical Switching Loss. DPA423-426 PART ORDERING INFORMATION DPA-Switch Product Family Series Number G Plastic Surface Mount DIP P Plastic DIP R Plastic TO-263-7C (available only with TL option) (423, 424 & 425 only) Package/Lead Options DPA 423 G - TL TL Tape & Reel, (G Package: 1000 min., R Package: 750 min.) K 1/04 31 DPA423-426 DIP-8 DIM inches D S .004 (.10) mm 8 A B C G H J1 J2 K L M N P Q 0.367-0.387 0.240-0.260 0.125-0.145 0.015-0.040 0.120-0.140 0.057-0.068 0.014-0.022 0.008-0.015 0.100 BSC 0.030 (MIN) 0.300-0.320 0.300-0.390 0.300 BSC 5 -E- 9.32-9.83 6.10-6.60 3.18-3.68 0.38-1.02 3.05-3.56 1.45-1.73 0.36-0.56 0.20-0.38 2.54 BSC 0.76 (MIN) 7.62-8.13 7.62-9.91 7.62 BSC B 1 4 -D- A M J1 Notes: 1. Package dimensions conform to JEDEC specification MS-001-AB for standard dual in-line (DIP) package .300 inch row spacing (PLASTIC) 8 leads (issue B, 7/85). 2. Controlling dimensions are inches. 3. Dimensions shown do not include mold flash G or other protrusions. Mold flash or protrusions shall not exceed .006 (.15) on any side. L 4. D, E and F are reference datums on the molded body. N C -FH K Q J2 P08A P PI-2076-101102 SMD-8 D S .004 (.10) 8 -E- 1 E S .010 (.25) P B .420 .046 .060 .080 .086 .186 .286 -D- A M .060 .046 Pin 1 4 L Solder Pad Dimensions J1 C K -F.004 (.10) J3 J4 G08A DIM inches mm A B C G H J1 J2 J3 J4 K L M P 0.367-0.387 0.240-0.260 0.125-0.145 0.004-0.012 0.036-0.044 0.057-0.068 0.048-0.053 0.032-0.037 0.007-0.011 0.010-0.012 0.100 BSC 0.030 (MIN) 0.372-0.388 0-8 9.32-9.83 6.10-6.60 3.18-3.68 0.10-0.30 0.91-1.12 1.45-1.73 1.22-1.35 0.81-0.94 0.18-0.28 0.25-0.30 2.54 BSC 0.76 (MIN) 9.45-9.86 0-8 5 J2 .010 (.25) M A S G H Notes: 1. Package dimensions conform to JEDEC specification MS-001-AB (issue B, 7/85) except for lead shape and size. 2. Controlling dimensions are inches. 3. Dimensions shown do not include mold flash or other protrusions. Mold flash or protrusions shall not exceed .006 (.15) on any side. 4. D, E and F are reference datums on the molded body. PI-2077-041003 32 K 1/04 DPA423-426 TO-263-7C .390 (9.91) .420 (10.67) .245 (6.22) min. .045 (1.14) .055 (1.40) .055 (1.40) .066 (1.68) .326 (8.28) .336 (8.53) .580 (14.73) .620 (15.75) .225 (5.72) min. .208 (5.28) Ref. -ALD #1 .024 (0.61) .034 (0.86) .100 (2.54) Ref. .050 (1.27) .000 (0.00) .010 (0.25) .090 (2.29) .110 (2.79) .010 (0.25) .012 (0.30) .024 (0.61) 0- 8 .315 (8.00) .380 (9.65) Solder Pad Dimensions .165 (4.19) .185 (4.70) .004 (0.10) .638 (16.21) .128 (3.25) .050 (1.27) .038 (0.97) Notes: 1. Package Outline Exclusive of Mold Flash & Metal Burr. 2. Package Outline Inclusive of Plating Thickness. 3. Foot Length Measured at Intercept Point Between Datum A Lead Surface. R07C 4. Controlling Dimensions are in Inches. Millimeter Dimensions are shown in Parentheses. PI-2664-112702 K 1/04 33 DPA423-426 34 K 1/04 DPA423-426 Revision Notes Date F 1) Final release data sheet. 6/02 G 2) Updated Figure 25 and text description. 9/02 H 1) 2) 3) 4) 4/03 I 1) Corrected text errors on pp. 1, 7 and 20. 5/03 J 1) Figure 25 and description in text updated. 5/03 K 1) Added P and G packages. 1/04 Corrected missing text on page 9 and corrected Table 4. Updated R package description. Revised thermal impedances (JA), DCMIN, VF, IF, and BVDSS. Updated Figure 25 and description in text. K 1/04 35 DPA423-426 For the latest updates, visit our Web site: www.powerint.com PATENT INFORMATION Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power Integrations does not assume any liability arising from the use of any device or circuit described herein, nor does it convey any license under its patent rights or the rights of others. The products and applications illustrated herein (including circuits external to the products and transformer construction) may be covered by one or more U.S. and foreign patents or potentially by pending U.S. and foreign patent applications assigned to Power Integrations. A complete list of Power Integrations' patents may be found at www.powerint.com. LIFE SUPPORT POLICY POWER INTEGRATIONS' PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF POWER INTEGRATIONS. As used herein: 1. Life support devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. The PI logo, TOPSwitch, TinySwitch, LinkSwitch and EcoSmart are registered trademarks of Power Integrations. PI Expert and DPA-Switch are trademarks of Power Integrations. (c)Copyright 2004, Power Integrations WORLD HEADQUARTERS Power Integrations 5245 Hellyer Avenue San Jose, CA 95138, USA. Main: +1-408-414-9200 Customer Service: Phone: +1-408-414-9665 Fax: +1-408-414-9765 e-mail: usasales@powerint.com CHINA (SHENZHEN) Power Integrations International Holdings, Inc. Rm# 1705, Bao Hua Bldg. 1016 Hua Qiang Bei Lu Shenzhen Guangdong, 518031, China Phone: +86-755-8367-5143 Fax: +86-755-8377-9610 e-mail: chinasales@powerint.com ITALY Power Integrations S.r.l. Via Vittorio Veneto 12, Bresso Milano, 20091, Italy Phone: +39-028-928-6001 Fax: +39-028-928-6009 e-mail: eurosales@powerint.com SINGAPORE (ASIA PACIFIC HEADQUARTERS) Power Integrations, Singapore 51 Newton Road #15-08/10 Goldhill Plaza Singapore, 308900 Phone: +65-6358-2160 Fax: +65-6358-2015 e-mail: singaporesales@powerint.com AMERICAS Power Integrations 4335 South Lee Street, Suite G Buford, GA 30518, USA Phone: +1-678-714-6033 Fax: +1-678-714-6012 e-mail: usasales@powerint.com GERMANY Power Integrations GmbH Rueckertstrasse 3 D-80336, Muenchen, Germany Phone: +49-89-5527-3910 Fax: +49-89-5527-3920 e-mail: eurosales@powerint.com JAPAN Power Integrations, K.K. Keihin-Tatemono 1st Bldg. 12-20 Shin-Yokohama 2-Chome, Kohoku-ku, Yokohama-shi, Kanagawa 222-0033, Japan Phone: +81-45-471-1021 Fax: +81-45-471-3717 e-mail: japansales@powerint.com TAIWAN Power Integrations International Holdings, Inc. 5F-1, No. 316, Nei Hu Rd., Sec. 1 Nei Hu Dist. Taipei, Taiwan 114, R.O.C. Phone: +886-2-2659-4570 Fax: +886-2-2659-4550 e-mail: taiwansales@powerint.com CHINA (SHANGHAI) Power Integrations International Holdings, Inc. Rm 807, Pacheer Commercial Centre 555 Nanjing West Road Shanghai, 200041, China Phone: +86-21-6215-5548 Fax: +86-21-6215-2468 e-mail: chinasales@powerint.com INDIA (TECHNICAL SUPPORT) Innovatech 261/A, Ground Floor 7th Main, 17th Cross, Sadashivanagar Bangalore 560080 Phone: +91-80-5113-8020 Fax: +91-80-5113-8023 e-mail: indiasales@powerint.com KOREA Power Integrations International Holdings, Inc. 8th Floor, DongSung Bldg. 17-8 Yoido-dong, Youngdeungpo-gu, Seoul, 150-874, Korea Phone: +82-2-782-2840 Fax: +82-2-782-4427 e-mail: koreasales@powerint.com APPLICATIONS HOTLINE World Wide +1-408-414-9660 APPLICATIONS FAX World Wide +1-408-414-9760 UK (EUROPE & AFRICA HEADQUARTERS) Power Integrations (Europe) Ltd. 1st Floor, St. James's House East Street Farnham Surrey GU9 7TJ United Kingdom Phone: +44 (0) 1252-730-140 Fax: +44 (0) 1252-727-689 e-mail: eurosales@powerint.com 36 K 1/04