Ver. 201207
※Rated Current (A)
*1
:DC current value when Inductance dropsto 30% of nominal Inductance value (ONLY REFERENCE)
※Rated Current (A)
*2
:DC current value when the self-generation of heat risesto 40℃(Reference ambient temperature:25℃)
※Operating temperature range: –40 to +125°C (Including self-temperature rise)
※Test equipment: Agilent :E4991A+16092A
1) Frequency characteristics (Typ.) 2) DC Bias characteristics (Typ.)
FEATURES
APPLICATION
CHARACTERISTIC DATA
Mobile phones, DSC, DVC, PDA etc. for DC-DC Converter
DIMENSION
TYPE Dimension [mm]
L W T D
22 2.5±0.2 2.0±0.2 0.8±0.1 0.55±0.25
DESCRIPTION
Part no. Size
(inch/mm) Inductance
(uH)@1MHz DC
Resistance(Ω)Rated Current (A)
*1
Typ. Rated Current (A)
*2
Max.
CIG22ER33MAE 1008/2520 0.33 ±20 % 0.060 ±20% 4.80 2.0
CIG22ER47MAE 1008/2520 0.47 ±20 % 0.060 ±25% 4.05 2.0
CIG22ER56MAE 1008/2520 0.56 ±20 % 0.075 ±20% 4.10 1.9
CIG22E1R0MAE 1008/2520 1.0 ±20 % 0.090 ±20% 2.30 1.9
CIG22E2R2MAE 1008/2520 2.2 ±20 % 0.146 ±20% 1.05 1.3
Multilayer Power Inductor
RECOMMENDED LAND PATTERN
CIG22E_MAE Series(2520/ EIA 1008)
High Current Type
Low DC resistance
Magnetically shielded structure
Free of all RoHS-regulated substances
Monolithic structure for high reliability