Cylindrical photoelectric sensors in M18 plastic or brass housings E3F2 * Complete sensor portfolio in plastic and metal housing * IP67, IP69K for highest water resistance * High immunity against electro-magnetic noise and ambient light * Special beam models * High power LED to compensate for dirt and misalignment Performance and portfolio variety Plastic Metal*1 90 Optics Through-beam 7m 7m - 3m Retro-reflective 4m 4m 2m 1m Diffuse-reflective 1m 1m 0.3 m 0.3 m 0.1 m 0.1 m Sensing method Diffuse-reflective (background suppression) *1 *2 Shape *2 AC power supply SUS types see seperate datasheet AC-types see seperate datasheet E3F2 L-on / D-on selectable by wiring M12 connector or pre-wired. 1 Selection Guide Housing Material: Plastic Sensing method Sensing distance Connection method Order code PNP output NPN output *1 Through-beam Retro-reflective with 7m M.S.R.*2 Retro-reflective with M.S.R. *2 Diffuse-reflective Diffuse-reflective Diffuse reflective (background suppression) *1. *2. *3. *4. - - 2m - E3F2-7B4 2M E3F2-7C4 2M - - - E3F2-7B4-P1 E3F2-7C4-P1 - - 2m - E3F2-R4B4-E 2M E3F2-R4C4-E 2M - - - E3F2-R4B4-P1-E E3F2-R4C4-P1-E - - 2m - E3F2-R2RB41-E 2M E3F2-R2RC41-E 2M - - - E3F2-R2RB41-P1-E E3F2-R2RC41-P1-E 0.1 m (fixed, wide-beam) - - 2m - E3F2-DS10B4-N 2M E3F2-DS10C4-N 2M - - - E3F2-DS10B4-P1 E3F2-DS10C4-P1 0.3 m (adjustable) - - 2m - E3F2-DS30B4 2M E3F2-DS30C4 2M - - - E3F2-DS30B4-P1 E3F2-DS30C4-P1 1m (adjustable) - - 2m - E3F2-D1B4 2M E3F2-D1C4 2M - - - E3F2-D1B4-P1 E3F2-D1C4-P1 - - 2m - E3F2-DS30B41 2M E3F2-DS30C41 2M - - - E3F2-DS30B41-P1 E3F2-DS30C41-P1 - - 2m - E3F2-LS10B4 2M E3F2-LS10C4 2M - - - E3F2-LS10B4-P1 E3F2-LS10C4-P1 0.1 to 4 m (adjustable)*3 0.1 to 2 m *4 0.3 m (adjustable) 0.1 m (fixed) Pre-wired connectors are available on request. Please contact your OMRON representative. Order reflector seperately. Models with reflector included are also available. Please contact your OMRON representative. Measured with reflector E39-R1S Measured with reflector E39-R1 Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable (e.g. E3F2-R4B4-E 5M). For other cable length please contact your OMRON sales representative. Housing material: Metal (Nickel plated brass) Sensing method Sensing distance Connection method Order code PNP output NPN output *1 Through-beam Retro-reflective with M.S.R.*2 Retro-reflective with M.S.R.*2 Diffuse-reflective Diffuse-reflective 2 7m - - 2m - E3F2-7B4-M 2M E3F2-7C4-M 2M - - - E3F2-7B4-M1-M E3F2-7C4-M1-M - - 2m - E3F2-R4B4-M-E 2M E3F2-R4C4-M-E 2M - - - E3F2-R4B4-M1-M-E E3F2-R4C4-M1-M-E - - 2m - - - - 0.1 m (fixed, wide-beam) - - 2m - E3F2-DS10B4-M 2M E3F2-DS10C4-M 2M - - - E3F2-DS10B4-M1-M E3F2-DS10C4-M1-M 0.3 m (adjustable) - - 2m - E3F2-DS30B4-M 2M E3F2-DS30C4-M 2M - - - E3F2-DS30B4-M1-M E3F2-DS30C4-M1-M 1m (adjustable) - - 2m - E3F2-D1B4-M 2M E3F2-D1C4-M 2M - - - E3F2-D1B4-M1-M E3F2-D1C4-M1-M E3F2-DS30B41-M 2M E3F2-DS30C41-M 2M 0.1 to 4 m (adjustable)*3 0.1 to 2 m*4 0.3 m (adjustable) - - 2m - - - - E3F2-R2RB41-M-E 2M E3F2-R2RC41-M-E 2M E3F2-R2RB41-M1-M-E E3F2-R2RC41-M1-M-E E3F2-DS30B41-M1-M E3F2-DS30C41-M1-M Standard Photoelectric Sensors Sensing method Sensing distance Connection method Order code PNP output NPN output E3F2-LS10B4-M 2M E3F2-LS10C4-M 2M E3F2-LS10B4-M1-M E3F2-LS10C4-M1-M *1 Diffuse-reflective (background suppression) *1. *2. *3. *4. 0.1 m (fixed) - - 2m - - - - Pre-wired connectors are available on request. Please contact your OMRON representative. Order reflector separately. Models with reflector E39-R1S included are available. Please contact your OMRON representative. with reflector E39-R1S with reflector E39-R1 Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable (e.g. E3F2-R4B4-E 5M). For other cable length please contact your OMRON sales representative. Accessories (Order Separately) Name Sensing distance (typical)*1 Remark Order code Reflectors 3 m [100 mm] (axial types) 2 m [100 mm] (radial types) 60 x 40 mm E39-R1 4 m [100 mm] (axial types) 2 m [100 mm] (radial types) 60 x 40 mm E39-R1S 5 m [100 mm] (axial types) 2.5 m [100 mm] (radial types) 84 mm E39-R7 6 m [100 mm] (axial types) 3 m [100 mm] (radial types) 100 x 100 mm E39-R8 5 m [100 mm] (axial types) 2.5 m [100 mm] (radial types) 80 x 80 mm E39-R40 Tape Reflectors 0.7 m [150 mm] (axial types) 1.1 m [150 mm] (axial types) 1.4 m [150 mm] (axial types) 35 x 10 mm E39-RS1 35 x 40 mm E39-RS2 80 x 70 mm Lens Cap Mounting Bracket *1. E39-RS3 E39-F31 screw mount Y92E-B18 Values in parentheses indicate the minimum required distance between the sensor and reflector. For detailed information about Accessories, refer to the main chapter "Accessories" at the end of the document. Sensor I/O Connectors Cord Shape Cable type Standard Straight 2m L-shaped Vibration-proof robot cable Straight L-shaped E3F2 Order code Four-wire type XS2F-D421-D80-A 5m XS2F-D421-G80-A 2m XS2F-D422-D80-A 5m XS2F-D422-G80-A 2m XS2F-D421-D80-R 5m XS2F-D421-G80-R 2m XS2F-D422-D80-R 5m XS2F-D422-G80-R 3 Specifications Ratings Item E3F2-7@ E3F2-R4@-@ E3F2-DS10@ Sensing method Through-beam Retro-reflective with M.S.R. Diffuse-reflective E3F2-DS30@ E3F2-D1@4-@ Wide beam Potentiometer adjustment Power supply voltage 10 to 30 VDC Current consumption 50 mA max. 30 mA max. 25 mA max. 30 mA max. Sensing distance 7m 0.1 to 4 m (with E39-R1S) 0.1 m (5 x 5 cm white mat paper) 0.3 m (10 x 10 cm white mat paper) Standard object Opaque: 11 mm dia. min. Opaque: 56 mm dia. min. - Directional angle 3 to 20 - Differential travel (hysteresis) - 20% max. 1m (30 x 30 cm white mat paper) E3F2-LS10@4-@ Background suppression 0.1 m (10 x 10 cm white mat paper) 5% max Black/white error - Response time Operation and Reset: 2.5 ms max. 3% Control output Transistor (open collector), load current: 100 mA max. (residual voltage: 2 V max.) 1 ms max 100 ms max. 2.5 ms max. 1 ms max. Power reset time 50 ms Ambient illumination Incandescent lamp:3000 lx max. / Sunlight:10000 lx max. 50 ms 100 ms Ambient temperature Operating: -25 to 55 C / Storage: -30 to 70 C (with no icing or condensation) Ambient humidity Operating: 35% to 85% / Storage: 35% to 95% (with no condensation) Insulation resistance 20 M min. at 500 V DC between energized parts and case Dielectric strength 1000 VAC max., 50 / 60 Hz for 1 min between energized parts and case Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z) Shock resistance Destruction: 500 m/s2 each direction (X, Y, Z) Degree of protection*1 IEC 60529 IP67, IP69K after DIN 40050-9 Light source (wave length) Infrared LED (950 nm) Red LED (660 nm) Infrared LED (880 nm) Indicators Light incident / power indicator for light source (red) Light incident (red) / stability (green) Light incident / power indicator for light source (red) Sensitivity adjustment Fixed Adjustable Fixed Connection method 2 m, 5 m pre-wired cable (PVC, dia. 4 mm (18 / Operation mode Light-ON or Dark-ON selectable by wiring Red LED (660 nm) Light incident (red) / stability (green) Adjustable 0.12)*2) Output indicator (orange) / stability (green) Fixed or M12-connector Weight (approx.) Plastic pre-wired case (2 m) Metal case 120 g 60 g connector 40 g 20 g pre-wired (2 m) 180 g 90 g 120 g 50 g connector Circuit protection Output short-circuit and power supply reverse polarity Housing materials*3 Case: ABS (plastic models) or nickel brass (metal models); lens: PMMA *1. *2. *3. 4 The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water at 80C is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from high pressure water in appearance and functionality. For other cable materials (e.g. PUR) contact your OMRON sales representative. For stainless steel types refer to separate datasheet E3F2 SUS Standard Photoelectric Sensors Engineering Data (Typical) Operating Range (typical) Through-beam Models (axial) Retro-reflective Models (axial) Retro-reflective Models (radial) E3F2-7@4-@ E3F2-R4@4@-@ (polarizing) E3F2-R2R@41-@ (polarizing) and reflectors 250 200 typical sensing distances: E39-R1: 2.4 m E39-R7: 2.7 m E39-R8: 3.1 m 50 100 Distance Y (mm) Distance Y (mm) 150 100 Typical sensing distance E39-RS3 E39-R1S E39-R40 E39-R7 E39-R8 50 0 - 50 - 100 0 -50 - 150 - 200 Y Y Reflector - 250 0 1 2 3 4 5 6 7 -100 8 0 9 0.5 1 1.5 2 2.5 3 3.5 Diffuse-reflective Models (axial) Diffuse-reflective Models (axial) Diffuse-reflective Models (radial) E3F2-DS10@4-@ (wide-beam type) E3F2-DS30@4-@ E3F2-DS30@41-@ 40 4 Distance X (m) Distance X (m) 15 Reflector X X 40 Sensitivity adjusted to maximum Sensitivity adjusted to 400 mm 30 30 20 20 Sensitivity adjusted to 390 mm White paper (90% reflectivity) white paper (50 x 50 mm) 0 -5 10 white paper (100 x 100 mm) 0 -10 -20 Distance Y (mm) 5 Distance Y (mm) Distance Y (mm) 10 10 Sensing object: 100 x 100 mm 0 -10 -20 Sensing distance adjustable between 0 and 550 mm -10 Y Object -30 Y X Object -30 20 40 60 80 100 120 140 Distance X (mm) Object X -40 -15 0 Y X -40 0 100 200 300 400 500 600 Distance X (mm) 0 100 200 300 400 500 Distance X (mm) Diffuse-reflective Models (axial) E3F2-D1@4-@ 100 80 Distance Y (mm) 60 40 20 Sensing object: 300 x 300 mm 0 -20 -40 -60 Y -80 Object X -100 0 200 400 600 800 1000 1200 1400 1600 Distance X (mm) E3F2 5 Excess Gain Ratio vs. Distance (typical) Through-beam Models (axial) Retro-reflective Models (axial) Retro-reflective Models (radial) E3F2-7@4-@ E3F2-R4@4@-@ E3F2-R2R@41-@ (polarizing) and reflectors 100 10 100 Reflectors: E39-RS3 E39-R1S E39-R40 E39-R7 E39-R8 1 Excess gain 10 Excess Gain Excess gain 100 1 10 reflector E39-R1 1 reflector E39-R7 reflector E39-R8 0.1 0 2 4 6 8 10 0.1 0.1 12 0 2 4 6 Distance X (m) 8 0 10 1 2 3 4 Diffuse-reflective Models (axial) Diffuse-eflective Models (axial) Diffuse-reflective Models (radial) E3F2-DS10@4-@ (wide-beam type) E3F2-DS30@4-@ E3F2-DS30@41-@ 100 100 White paper (90% reflectivity) Grey paper (18% reflectivity) 10 Excess gain Excess gain Excess gain Sensing object: 100 x 100 mm Sensitivity adjusted to 390 mm 10 1 100 Sensitivity adjusted to maximum Sensing object: 100 x 100 mm Sensing object: 50 x 50 mm White paper (90% reflectivity) 1 10 White paper (90% reflectivity) 1 Grey paper (18% reflectivity) Grey paper (18% reflectivity) 0.1 0.1 0 20 40 60 80 100 120 5 Distance X (m) Distance X (m) 0.1 0 140 200 400 600 800 1000 Distance X (mm) Distance X (mm) 0 100 200 300 400 500 Distance X (mm) Diffuse-reflective Models (axial) E3F2-D1@4-@ Excess gain 100 10 1 0,1 0 0.5 1 1.5 2 Distance(m) 6 Standard Photoelectric Sensors Light spot vs sensing distance Incline (horizontal) Incline (vertical) Background suppression Models Background suppression Models Background suppression Models E3F2-LS@ E3F2-LS@ E3F2-LS@ 4 2 Sensing Distence movement (%) Sensing Distence movement (%) Spot diameter(mm) 20,00% 20,00% 6 10,00% 0,00% -10,00% 0 50 100 150 Distance(mm) 0,00% -10,00% -20,00% -20,00% 0 10,00% -40 -30 -20 -10 0 10 20 30 40 Incline Angle () -40 -30 -20 -10 0 10 20 30 40 Incline Angle () Object material vs sensing distance Background suppression Models Sensing distance (mm) E3F2-LS@ 120 100 80 60 40 20 0 White Veneer Card- Black Black SUS paper board paper rubber Mirror surface Material E3F2 7 Operation Output Circuits Structure of Sensor I/O Connector 1 2 3 4 Classification Wire color Connector Use pin No. Brown White Blue Black DC XS2F-D42#-D80-# XS2F-G42#-G80-# Brown Power supply (+V) White Mode selection Lon/Don Blue Power supply (0 V) Black Output PNP Output Model Output transistor Timing chart status Connection method Output circuit E3F2-@B4-@ (except for E3F2-LS10B4-@) - - Through-beam emitter - Brown 10 to 30 VDC 1 Power indicator (red) Main circuit Blue 3 0V Connector Pin Arrangement 1 2 4 3 ON when light is incident. (Light-ON) Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Operate Release Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Light indicator Red Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Connect the pink (Pin ) and blue (Pin ) cords. 10 to 30 VDC 1 ZD Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. Load 3 0V Pink Mode selection 2 Connector Pin Arrangement 1 * Only on models E3F2-R4B4-@ and E3F2-D1B4-@ ON when light is interrupted. (Dark-ON) Brown Stability indicator* Light indicator Red 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. Load 3 0V Pink Load (relay) Operate Release Connector Pin Arrangement 1 * Only on models E3F2-R4B4-@ and E3F2-D1B4-@ E3F2-LS10B4-@ ON when light is incident. (Light-ON) Incident Interrupted Output indicator (orange) ON OFF Output transistor ON OFF Load (relay) Operate Release Mode selection 2 Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Output indicator Orange 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 ZD Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. Load 3 0V Pink Mode selection 2 Connector Pin Arrangement 1 2 4 3 ON when light is interrupted. (Dark-ON) Incident Interrupted Output indicator (orange) ON OFF Output transistor ON OFF Connect the pink (Pin ) and blue (Pin ) cords. Output indicator Orange Brown Stability indicator* 10 to 30 VDC 1 Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. 3 Load 0V Pink Load (relay) Operate Release 2 Mode selection Connector Pin Arrangement 1 2 4 3 Note: Terminal numbers for connector type. 8 Standard Photoelectric Sensors NPN Output Model Output transistor Timing chart status Connection method Output circuit E3F2-@C4-@ (except for E3F2-LS10C4-@) - - Through-beam emitter Brown 10 to 30 VDC 1 Power indicator (red) Main circuit Blue 3 0V Connector Pin Arrangement 1 2 4 3 ON when light is incident. (Light-ON) Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Operate Release Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Output indicator Red Brown Stability indicator* Green Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Connect the pink (Pin ) and blue (Pin ) cords. ON when light is incident. (Light-ON) Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Operate Release Blue 3 0V Pink Mode selection 2 Connector Pin Arrangement Output indicator Red 1 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 Green 100 mA max. Black 4 Main circuit Load Blue 3 0V ZD: VZ = 36 V Pink Mode selection 2 Operate Release Incident Interrupted Load ZD: VZ = 36 V Connector Pin Arrangement 1 * Only on models E3F2-R4C4-@ and E3F2-D1C4-@ E3F2-LS10C4-@ 100 mA max. Black 4 Main circuit * Only on models E3F2-R4C4-@ and E3F2-D1C4-@ ON when light is interrupted. (Dark-ON) 10 to 30 VDC 1 Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Output indicator Orange 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 Green 100 mA max. Black 4 Main circuit Load Blue 3 0V ZD: VZ = 36 V Pink Mode selection 2 Connector Pin Arrangement 1 2 4 3 ON when light is interrupted. (Dark-ON) Incident Interrupted Output indicator (orange) ON OFF Output transistor ON OFF Connect the pink (Pin ) and blue (Pin ) cords. Output indicator Orange Brown Stability indicator* 10 to 30 VDC 1 Green 100 mA max. Black 4 Main circuit Load Blue 3 0V ZD: VZ = 36 V Pink Load (relay) Operate Release 2 Mode selection Connector Pin Arrangement 1 2 4 3 Note: Terminal numbers for connector type. E3F2 9 Dimensions Note: All units are in millimeters unless otherwise indicated Plastic models, axial type Cable type Connector type Without potentiometer E3F2-7@-P1 E3F2-DS10@4-P1 E3F2-LS10@4-P1 5 5 Light indicator 4 M12x1 6g 24 optical area 24 22 6.2 22 optical area 4.7 dia 6.2 37 4 dia 42.3 16.4 dia 64.9 73 62 42.3 37 4.8 dia 16.6 dia E3F2-7@ E3F2-DS10@4-N E3F2-LS10@4 Light indicator 4 M18x1 6g M18x1 6g 8 8 With potentiometer E3F2-DS30@4-P1 E3F2-D1@4-P1 E3F2-R4@-P1 22 5 5 4 8 Sensitivity adjustor Light indicator optical area 24 6.2 24 4.7 dia 22 6.2 16.4 dia optical area M12x1 6g 73 62 49.3 42.3 37 4.8 dia 4 dia 64.9 49.3 42.3 37 16.6 dia E3F2-DS30@4 E3F2-D1@4 E3F2-R4@ Sensitivity adjustor 4 8 Light indicator M18x1 6g M18x1 6g 10 Standard Photoelectric Sensors Plastic models, radial type Cable type Connector type Without potentiometer E3F2-R2R@41-P1 5 5 Light indicator 6.9 4 24 22 optical area 22 4 dia 24 4.7 dia 13.2 optical area 16.4 dia 42.3 37 73 62 42.3 37 4.8 dia 13.2 64.9 M12x1 6g 16.6 dia E3F2-R2R@41 3.45 Light indicator 4 6.9 M18x1 6g 3.45 M18x1 6g 8 8 With potentiometer 4.7 dia 5 4 8 Sensitivity adjustor Light indicator 24 22 3.45 6.9 optical area 13.2 24 13.2 optical area M12x1 6g 73 62 49.3 42.3 37 22 4 dia 37 4.8 dia 16.4 dia 64.9 49.3 42.3 E3F2-DS30@41-P1 16.6 dia E3F2-DS30@41 5 Sensitivity adjustor 6.9 4 8 3.45 Light indicator M18x1 6g M18x1 6g E3F2 11 Metal Models, axial type Cable type Connector type Without potentiometer E3F2-7@-M1-M E3F2-DS10@4-M1-M E3F2-LS10@4-M1-M 76 4 4.8 dia 42.3 37 optical area 24 6.2 27.7 24 4 Light indicator 6.2 optical area M12x1 6g 65.5 27.7 4 dia 4.8 dia 16.4 dia 64.9 42.3 37 16.4 dia E3F2-7@-M E3F2-DS10@4-M E3F2-LS10@4-M Light indicator M18x1 6g M18x1 6g With potentiometer E3F2-DS30@4-M1-M E3F2-R4@4-M1-M E3F2-D1@4-M1-M E3F2-DS30@4-M E3F2-R4@4-M E3F2-D1@4-M 76 65.5 37 4 Sensitivity adjustor Light indicator M18x1 6g 27.7 optical area 4 24 6.2 24 4.8 dia 16.4 dia 49.3 42.3 M12x1 6g optical area 27.7 6.2 16.4 dia 4.8 dia 4 dia 64.9 49.3 42.3 37 Sensitivity adjustor Light indicator M18x1 6g 12 Standard Photoelectric Sensors Metal Models, radial type Cable type Connector type Without potentiometer 76 65.5 42.3 37 4.8 dia 6.9 4 13.2 optical area 24 27.7 16.4 dia 24 13.2 optical area 27.7 42.3 37 4.8 dia 4 dia 16.4 dia 64.9 E3F2-R2R@41-M1 M12x1.6g E3F2-R2R@41-M 3.45 Light indicator M18x1 6g 6.9 4 3.45 Light indicator M18x1.6g With potentiometer E3F2-DS30@41-M 76 65.5 6.9 E3F2 4 Sensitivity adjustor Light indicator M18x1 6g optical area 27.7 24 13.2 16.4 dia 37 27.7 24 4.8 dia M12x1 6g 49.3 42.3 optical area 13.2 4.8 dia 4 dia 16.4 dia 64.9 49.3 42.3 37 E3F2-DS30@41-M1-M 3.45 6.9 4 Sensitivity adjustor 3.45 Light indicator M18x1 6g 13 Accessories (Order Separately) Reflector E39-R1 E39-R1S E39-R7 Two, 3.5 dia. 7.4 40.3 34 84 7.5 7 4.5 59.9 52 8 Material, reflective surface: acrylic Rear surface: ABS 2.7 1.6 E39-R8 E39-R40 9 8.7 100 84.5 77 92 92 77 100 for M3 for 84.5 for M3 Tape relectors E39-RS3 E39-RS1 35 0.6 0.7 10 80 Reflecting surface 4 x R1 70 Adhesive tape E39-RS2 40 0.7 35 4-R1 Adhesive tape side Reflecting surface 4 x R1 Adhesive tape Installation Mounting Bracket Y92E-B18 Lens Cap E39-F31 Glass plate Metal rim E3F2 Gasket 4 max. Note: Hexagon bolt: M5 x 32 Material: plastic 20 dia. 14 Standard Photoelectric Sensors Safety precautions Precautions for Correct Use ! Warning This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. ! Caution Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explostion may result. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0.39 to 0.49 N*m for M12 connectors. Load Do not use a load that exceeds the rated load. Rotation Torque for Sensitivity Adjustment Adjust with a torque of 0.05 N*m or less. Environements with Cleaners and Disinfectants (e.g., Food Processing Lines) Do not use the Sensor in environments subject to cleaners and disifectants. They may reduce the degree of protection. Modifications Do not attempt to disassemble, repair, or modify the Sensor. Outdoor Use Do not use the Sensor in locations subject to direct sunlight. Cleaning Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded. Do not use the Sensor in any atmosphere or environment that exceeds the ratings. Do not install the Sensor in the following locations. (1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity (3) Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock Connecting and Mounting (1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0.3 mm2 and less than 100 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. (6)Mount the Sensor using a bracket (sold separately). Do not exceed a torque of 2.0 Nm when tightening mounting nuts for plastic models or 20.0 Nm when tightening mounting nuts for metal models (7) Be sure to turn OFF the power supply before inserting or removing the connector. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Power Supply Reset Time The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Turning OFF the Power Supply Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. Load Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn OFF, so check the wiring before turning ON the power supply again. The short-circuit protection circuit will be reset. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. Surface Temperature Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor. E3F2 15 WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the DIMENSIONS AND WEIGHTS customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Cat. No. E58E-EN-01 Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www.industrial.omron.eu 16 Standard Photoelectric Sensors Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E3F2-DS10Z2-N E3F2-7C4 E3F2-3Z1 E3F2-3Z2 E3F2-R2Z2 E3F2-R2Z1 E3F2-DS30C4 E3F2-DS10B4-S E3F2DS10C4-S E39-F31 E39-R7 E39-R8 E3F2-7B4-M E3F2-7B4-M 10M E3F2-7B4-M1-M E3F2-7B4-M1-S E3F2-7B4M 5M E3F2-7B4-P1 E3F2-7B4-S E3F2-7C4-M 10M E3F2-7C4-M1-M E3F2-7C4-M1-S E3F2-7C4-M 5M E3F2-7C4S E3F2-D1B4-P1 E3F2-D1C4 2M E3F2-DS10B4-M 10M E3F2-DS10B4-M1-S E3F2-DS10B4-M 5M E3F2-DS10C4M 10M E3F2-DS10C4-M1-S E3F2-DS10C4-M 5M E3F2-DS10Z1-N 10M E3F2-DS30B41 5M E3F2-DS30B41-M E3F2-DS30B41-M1-M E3F2-DS30B41-M 5M E3F2-DS30C41 E3F2-DS30C41 5M E3F2-DS30C41-M E3F2DS30C41-M 5M E3F2-DS30C41-P1 E3F2-LS10B4 E3F2-LS10C4-P1 E3F2-R2B4-E E3F2-R2RB41 E3F2-R2RB41 5M E3F2-R2RB41-E E3F2-R2RB41-E 5M E3F2-R2RB41-M E3F2-R2RB41-M1-M-E E3F2-R2RB41-M 5M E3F2R2RB41-M-E E3F2-R2RB41-M-E 5M E3F2-R2RB41-P1 E3F2-R2RB41-P1-E E3F2-R2RB4-M E3F2-R2RB4-M 10M E3F2-R2RB4-M1-M-E E3F2-R2RB4-M1-S E3F2-R2RB4-M-E E3F2-R2RB4-M-E 10M E3F2-R2RC41 E3F2-R2RC41 5M E3F2-R2RC41-E 5M E3F2-R2RC41-M E3F2-R2RC41-M1-M-E E3F2-R2RC41-M 5M E3F2-R2RC41-M-E E3F2R2RC41-M-E 5M E3F2-R2RC41-P1-E E3F2-R2RC4-M 10M E3F2-R2RC4-M1-M-E E3F2-R2RC4-M1-S E3F2R2RC4-M 5M E3F2-R2RC4-M-E E3F2-R2RC4-M-E 10M E3F2-R2RC4-M-E 5M E3F2-R2RC4-S E3F2-R4B4-M 2M E3F2-R4C4-M-E E3F2-R2B4 5M E3F2-R4C4F E3F2-R4C4F-M 2M E3F2-R4C4-E E3F2-LS10C4-M1-M E3F2R4B4-M-E E3F2-R4B4F E3F2-DS30B4 5M E3F2-R4C4F-P1 E3F2-R4C4-P1-E E3F2-R4B4F-P1-E E3F2-R4B4FM1-M-E E3F2-R4B4-E E3F2-R4C4F-E E3F2-R4C4F-M1-M-E E3F2-R4B4F-M-E E3F2-DS30C4-S E3F2-R4B4-P1-E E3F2-DS30B4-S