■Features
CXA-0217
CXA-0217 Specifications
(Please refer to each specification before use)
■Applications
Dimming/ConnectorType
●2-output
●UL60950approved
●Applicablepanelsize*:10to15inches
●Withbrightnesscontrolfunction(Acurrentsystem).
●Inthehigh-voltagegenerator(aterminalandapattern),
ananti-dustmeasurebysiliconeapplicationistaken.
(Notice)Applicablepanelsizebecomesastandard.
ElectricalCharacteristics
OtherSpecifications
Item Unit Symbol Specification Condition
min typ max Vin(V) Vrmt(V) Vbr(V) Ta(℃ ) RL(kΩ) Remark
OutputCurrent mArms
Iout
(Maximumdimmer)
5.5 6.0 6.5 121.2 5 0 0to+70 95 (*1)
5.3 6.0 6.7 122.4 5 0 0to+70 76to114 (*1)
Iout
(Minimumdimmer)
1.7 2.0 2.4 121.2 5 3.4 0to+70 250 (*1)
1.65 2.0 2.45 122.4 5 3.4 0to+70 250 (*1)
InputCurrent A Iin1 - 0.76 1.2 121.2 5 0 0to+70 76to114
A Iin2 - 0.76 1.3 122.4 5 0 0to+70 76to114
Frequency kHz Freq 52 58 64 122.4 5 0 0to+70 95
OpenCircuitVoltage
Vrms Vopen 1400 1500 2000 9.6min. 5 0to3.4 0to+70 ∞ Openload
(*1)Pleaserefertotheconnectiondiagramfordetailsofadimmingmethod.
DimmingFunction
Yes
OperatingTemperature
℃ 0to+70
StorageTemperature
℃ -30to+85
OperatingHumidityRatio
RH% 95Max
SafetyStandard
UL60950
Weight g 30
Dimensions(WxDxH)
mm 180x25x8(*2)
FusedInput Yes
RemoteON / OFF
Yes
AlarmSignalFunction
No
ShutdownFunction
No
SiliconeCoatingon
HighVoltageArea
Yes
(*2)Thesedimensions areindicated themaximum onlyH. Othersare typical
values.
Thismeansthat,inconformitywithEUDirective
2002/95/EC,lead,cadmium,mercury,hexavalent
chromium,andspecificbromine-basedflame
retardants,PBBandPBDE,havenotbeenused,
exceptforexemptedapplications.
■
ConformitytoRoHsDirective
001-01/20080228/etl_cxa_0217
Allspecificationsaresubjecttochangewithoutnotice.
1