Current Transducer HAS 50 .. 600-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 50 .. 600 A Electrical data Type Primary nominal Primary current, RoHS since current rms measuring range date code IPN (A) IPM (A) HAS 50-P 50 150 46065 HAS 100-P 100 300 46062 HAS 200-P 200 600 76273 HAS 300-P 300 900 76273 HAS 400-P 400 900 46131 HAS 500-P 500 900 46216 HAS 600-P 600 900 76273 VC Supply voltage ( 5 %) 1) 15 V IC Current consumption 15 mA RIS Isolation resistance @ 500 VDC > 1000 M VOUT Output voltage (Analog) @ IPN, RL =10 k, TA = 25C 4 V 40 mV ROUT Output internal resistance approx 100 RL Load resistance 2) > 1 k Accuracy - Dynamic performance data X Accuracy @ IPN , TA = 25C (excluding offset) < 1 % Linearity error 3) (0 .. IPN) < 1 % of IPN VOE Electrical offset voltage, TA = 25C < 20 mV VOH Hysteresis offset voltage @ IP = 0, after an excursion of 1 x IPN < 20 mV TCVOE Temperature coefficient of VOE HAS 50-P < 2 mV/K HAS 100 .. 600-P < 1 mV/K TCVOUT Temperature coefficient of VOUT (% of reading) < 0.1 %/K tr Response time to 90 % of IPN step < 3 s di/dt di/dt accurately followed > 50 A/s BW Frequency bandwidth 4) (small signal, - 3 dB) DC .. 50 kHz L General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards 5) - 10 .. + 80 - 25 .. + 85 80 EN 50178:1997 C C g Operating at 12 V VC < 15 V will reduce the measuring range. If the customer uses 1 k of the load resistor, the primary current has to be limited as the nominal. To measure the full defined measuring range, the load resistor should be at minimum 10 k. 3) Linearity data exclude the electrical offset. Notes: 1) 2) Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Isolation voltage 3000 V Low power consumption Extended measuring range (3 x IPN) Isolated plastic case made of polycarbonate PBT recognized according to UL 94-V0 Right angle pins for direct PCB mounting. Advantages Easy mounting Small size and space saving Only one design for wide current ratings range High immunity to external interference. Applications AC variable speed drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Application domain Industrial. Please refer to derating curves in the technical file to avoid excessive core heating at high frequency. 5) Please consult characterisation report for more technical details and application advice. 4) 100329/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/3 www.lem.com Current Transducer HAS 50 .. 600-P Isolation characteristics Vd Vw dCp dCI CTI Rms voltage for AC isolation test, 50 HZ, 1 min Impulse withstand voltage 1.2/50 s Creepage distance Clearance distance Comparative Tracking Index (group IIIa) 3.6 > 6.6 Min 7.08 6.23 275 kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: Over voltage category OV 3 Pollution degree PD2 Non-uniform field EN 50178 IEC 61010-1 Rated isolation voltage Nominal voltage Single isolation 600 V 600 V Reinforced isolation 300 V 300 V dCp, dCI, Vw Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 100329/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com DimensionsHAS HAS50 50..600-P Dimensions .. 600-P (in (inmm. mm.11mm mm==0.0394 0.0394inch) inch) Secondary terminals PINS ARRANGEMENT Terminal 1 : Supply voltage + 15 V Terminal : Supply voltage - 15 V 1. 2+15V 2. 3-15V Terminal : Output 3. 4OUTPUT Terminal : 0V 4. 0V 4- 0.64 3 Mechanical characteristic characteristics Mechanical General tolerance * General tolerance 0.5 mm Safety 0.5 mm This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 061019/3 100329/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 3/3 www.lem.com www.lem.com