OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 visibleLED@optekinc.com www.optekinc.com
Issue D 05/2011
Page 2 of 2
Storage Temperature Range -40 ~ +80 °C
Operating Temperature Range -30 ~ +50 °C
Input Voltage 15 V
Power Dissipation 1.5 W
LED Junction Temperature 125 oC
Electrostatic Discharge Classification (JEDEC-JESD22-A114F) Class 1C
Absolute Maximum Ratings (TA = 25o C unless otherwise noted)
Notes:
1. Lead Solder time less than 10 seconds at temperature extreme.
2. No Heat sink is required if the string is operated at ambient temperature < 35°C. For long term performance the drive voltage at 12 V is
recommended. Please contact an Optek sales representative for more information on recommended drive conditions.
Electrical & Mechanical Characteristics / module (TA = 25o C unless otherwise noted)
SYMBOL Notes MIN TYP MAX UNITS CONDITIONS
Power
Consumption
Red/Yellow
Green/Blue/White 0.5
0.3 - - - W VDC = 12 V
VDC Input Voltage - - - 12 - - - V
Net Weight - - - 16 - - - g Per module
λD Dominant Wavelength - - - See chart
2 Θ½ 50% Power Angle ---- 120 ---- deg VDC = 12 V
3 LED Module
(30 modules / string)
Package Information:
1 tray contains 2 strings of 30 modules each. Modules are packaged 60 per tray.
If an entire string is not required for the application, clip wires at mid-span:
Modules can be secured onto a mounting surface with two #6 screws. Modules are waterproof and can be used
outdoors. The installer is responsible for waterproofing the connection to the power source. The installer is also
responsible for the use of an exterior approved power source.