PROFET® ITS 640S2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, Vbb = 12 V unless otherwise specified min typ max
Infineon Technologies AG Page 5 2006-Mar-28
Protection Functions7)
Initial peak short circuit current limit (pin 4 to 6&7) IL(SCp)
Tj =-40°C:
Tj =25°C:
Tj =+150°C:
48
40
31
56
50
37
65
58
45
A
Repetitive short circuit shutdown current limit IL(SCr)
Tj = Tjt (see timing diagrams, page 11) -- 24 -- A
Output clamp (inductive load switch off)
at VOUT = Vbb - VON(CL); IL= 40 mA, Tj =-40°C:
Tj =+25..+150°C:
VON(CL)
41
43
--
47
--
52
V
Thermal overload trip temperature Tjt 150 -- -- °C
Thermal hysteresis
∆
Tjt -- 10 -- K
Reverse battery (pin 4 to 2) 8) -Vbb -- -- 32 V
Reverse battery voltage drop (Vout > Vbb)
IL = -5 A T
j=150 °C:
-VON(rev)
--
600 -- mV
Diagnostic Characteristics
Current sense ratio9), static on-condition,
VIS = 0...5 V, Vbb(on) = 6.510)...27V,
kILIS = IL / IIS Tj = -40°C, IL = 5 A:
kILIS
4550
5000 6000
Tj= -40°C, IL= 0.5 A: 3300 5000 8000
Tj= 25...+150°C, IL= 5 A:
, Tj= 25...+150°C, IL = 0.5 A:
4550
4000
5000
5000
5550
6500
Current sense output voltage limitation
Tj = -40 ...+150°C IIS = 0, IL = 5 A:
VIS(lim)
5.4
6.1 6.9 V
Current sense leakage/offset current
Tj = -40 ...+150°C VIN=0, VIS = 0, IL = 0:
IIS(LL)
0
-- 1µA
VIN=5 V, VIS = 0, IL = 0: IIS(LH) 0 -- 15
VIN=5 V, VIS = 0, VOUT = 0 (short circuit): IIS(SH)11 ) 0 -- 10
7) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
8) Requires 150 Ω resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 8).
9) This range for the current sense ratio refers to all devices. The accuracy of the kILIS can be raised at least by
a factor of two by matching the value of kILIS for every single device.
In the case of current limitation the sense current IIS is zero and the diagnostic feedback potential VST is
High. See figure 2b, page 10.
10) Valid if Vbb(u rst) was exceeded before.
11) not subject to production test, specified by design