PROFET® ITS 640S2
Infineon Technologies AG Page 1 of 15 2006-Mar-28
Smart Sense High-Side Power Switch
For Industrial Applications
Features
Short circuit protection
Current limitation
Proportional load current sense
CMOS compatible input
Open drain diagnostic output
Fast demagnetization of inductive loads
Undervoltage and overvoltage shutdown with
auto-restart and hysteresis
Overload protection
Thermal shutdown
Overvoltage protection including load dump
(with external GND-resistor)
Reverse battery protection (with external GND-
resistor)
Loss of ground and loss of Vbb protection
Electrostatic discharge (ESD) protection
Application
µC compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads in industrial
applications
All types of resistive, inductive and capacitive loads
Replaces electromechanical relays, fuses and discrete circuits
General Description
N channel vertical power FET with charge pump, ground referenced CMOS compatible input and diagnostic
feedback, proportional sense of load current, monolithically integrated in Smart SIPMOS technology.
Providing embedded protective functions.
Block Diagram
IN
ST ESD Logic
Voltage
sensor
Voltage
source
Charge pump
Level shifter
Temperature
sensor
Rectifier
Limit for
unclamped
ind. loads
Gate
protection
Current
limit
3
1
Signal GND
GND
2
VLogic
Overvoltage
protection
+ Vbb
PROFET
OUT
4
6, 7
Load GND
Load
GND
RO
Current
Sense
Output
Voltage
detection
RIS
IS
5
IIS
IL
Product Summary
Operating voltage V
bb(on) 5.0 ... 34 V
On-state resistance RON 30 m
Load current (ISO) IL(ISO) 12.6 A
Current limitation IL(SCr) 24 A
Operating temperature Ta -30 … +85 °C
Package
PG-TO220-7-11 PG-TO220-7-12
Standard (staggered) Straight
11
PROFET® ITS 640S2
Infineon Technologies AG Page 2 2006-Mar-28
Pin Symbol Function
1 ST Diagnostic feedback: open drain, invers to input level
2 GND Logic ground
3 IN Input, activates the power switch in case of logical high signal
4 Vbb Positive power supply voltage, the tab is shorted to this pin
5 IS Sense current output, proportional to the load current, zero in
the case of current limitation of load current
6 & 7 OUT
(Load, L) Output, protected high-side power output to the load.
Both output pins have to be connected in parallel for operation
according this spec (e.g. kILIS).
Design the wiring for the max. short circuit current
Maximum Ratings at Tj = 25 °C unless otherwise specified
Parameter Symbol Values Unit
Supply voltage (overvoltage protection see page 4) Vbb 43 V
Supply voltage for full short circuit protection
Tj Start=-40 ...+150°C
Vbb 34 V
Load dump protection1) VLoadDump = VA + Vs, VA = 13.5V
RI2)= 2 , RL= 1 , td= 200 ms, IN= low or high
VLoad dump3) 60 V
Load current (Short circuit current, see page 5) IL self-limited A
Junction temperature
Operating temperature range
Storage temperature range
Tj
Ta
Tstg
+150
-30 ...+85
-40 ...+105
°C
Power dissipation (DC), TC 25 °C Ptot 85 W
Inductive load switch-off energy dissipation, single pulse
Vbb = 12V, T
j,start = 150°C, T
C = 150°C const.
IL = 12.6 A, ZL = 4,2 mH, 0 :
IL = 4 A, ZL = 330 mH, 0 :
EAS
EAS
0,41
3,5
J
Electrostatic discharge capability (ESD) IN:
(Human Body Model) ST, IS:
out to all other pins shorted:
acc. MIL-STD883D, method 3015.7 and ESD assn. std. S5.1-1993
R=1.5k; C=100pF
VESD 1.0
4.0
8.0
kV
Input voltage (DC) VIN -10 ... +16 V
Current through input pin (DC)
Current through status pin (DC)
Current through current sense pin (DC)
see internal circuit diagrams page 7
IIN
IST
IIS
±2.0
±5.0
±14
mA
1) Supply voltages higher than Vbb(AZ) require an external current limit for the GND and status pins (a 150
resistor in the GND connection is recommended).
2) RI = internal resistance of the load dump test pulse generator
3) VLoad dump is setup without the DUT connected to the generator according to ISO 7637-1 and DIN 40839
PROFET® ITS 640S2
Infineon Technologies AG Page 3 2006-Mar-28
Thermal Characteristics
Parameter and Conditions Symbol Values Unit
min typ max
Thermal resistance chip - case: RthJC -- -- 1.47 K/W
junction - ambient (free air): RthJA -- -- 75
Electrical Characteristics
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, Vbb = 12 V unless otherwise specified min typ max
Load Switching Capabilities and Characteristics
On-state resistance (pin 4 to 6&7)
IL = 5 A T
j=25 °C:
T
j=150 °C:
RON
--
27
54
30
60
m
Output voltage drop limitation at small load
currents (pin 4 to 6&7), see page 13
IL = 0.5 A Tj =-40...+150°C:
VON(NL)
--
50 -- mV
Nominal load current, ISO Norm (pin 4 to 6&7)
VON = 0.5 V, T
C = 85 °C
IL(ISO)
11.4
12.6 -- A
Nominal load current, device on PCBFehler! Textmarke
nicht definiert.)
TA = 85 °C, Tj 150 °C VON 0.5 V,
IL(NOM)
4.0
4.5 -- A
Output current (pin 6&7) while GND disconnected
or GND pulled up, Vbb=30 V, VIN= 0, see diagram page
9; not subject to production test, specified by design
IL(GNDhigh) -- -- 8 mA
Turn-on time IN to 90% VOUT:
Turn-off time IN to 10% VOUT:
RL = 12 , Tj =-40...+150°C
ton
toff
25
25
70
80
150
200 µs
Slew rate on
10 to 30% VOUT, RL = 12 , Tj =-40...+150°C
dV /dton 0.1 -- 1 V/µs
Slew rate off
70 to 40% VOUT, RL = 12 , Tj =-40...+150°C
-dV/dtoff 0.1 -- 1 V/µs
PROFET® ITS 640S2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, Vbb = 12 V unless otherwise specified min typ max
Infineon Technologies AG Page 4 2006-Mar-28
Operating Parameters
Operating voltage 4) Tj =-40...+150°C: Vbb(on) 5.0 -- 34 V
Undervoltage shutdown Tj =-40...+150°C: Vbb(under) 3.2 -- 5.0 V
Undervoltage restart Tj =-40...+25°C:
Tj =+150°C:
Vbb(u rst) -- 4.5 5.5
6.0
V
Undervoltage restart of charge pump
see diagram page 12 Tj =-40...+25°C:
Tj =25...150°C:
Vbb(ucp)
--
--
4.7
--
6.5
7.0
V
Undervoltage hysteresis
Vbb(under) = Vbb(u rst) - Vbb(under)
Vbb(under) -- 0.5 -- V
Overvoltage shutdown Tj =-40...+150°C: Vbb(over) 34 -- 43 V
Overvoltage restart Tj =-40...+150°C: Vbb(o rst) 33 -- -- V
Overvoltage hysteresis Tj =-40...+150°C: Vbb(over) -- 1 -- V
Overvoltage protection5) Tj =-40°C:
Ibb=40 mA Tj =+25...+150°C
Vbb(AZ) 41
43
--
47
--
52
V
Standby current (pin 4)
VIN=0 T
j=-40...+25°C:
T
j= 150°C:
Ibb(off)
--
--
4
12
15
25 µA
Off state output current (included in Ibb(off))
VIN=0, Tj =-40...+150°C:
IL(off) -- -- 10 µA
Operating current (Pin 2)6), VIN=5 V IGND -- 1.2 3 mA
4) At supply voltage increase up to Vbb= 4.7 V typ without charge pump, VOUT Vbb - 2 V
5) Supply voltages higher than Vbb(AZ) require an external current limit for the GND and status pins (a 150
resistor in the GND connection is recommended). See also VON(CL) in table of protection functions and
circuit diagram page 8.
6) Add IST, if IST > 0, add IIN, if VIN>5.5 V
PROFET® ITS 640S2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, Vbb = 12 V unless otherwise specified min typ max
Infineon Technologies AG Page 5 2006-Mar-28
Protection Functions7)
Initial peak short circuit current limit (pin 4 to 6&7) IL(SCp)
Tj =-40°C:
Tj =25°C:
Tj =+150°C:
48
40
31
56
50
37
65
58
45
A
Repetitive short circuit shutdown current limit IL(SCr)
Tj = Tjt (see timing diagrams, page 11) -- 24 -- A
Output clamp (inductive load switch off)
at VOUT = Vbb - VON(CL); IL= 40 mA, Tj =-40°C:
Tj =+25..+150°C:
VON(CL)
41
43
--
47
--
52
V
Thermal overload trip temperature Tjt 150 -- -- °C
Thermal hysteresis
Tjt -- 10 -- K
Reverse battery (pin 4 to 2) 8) -Vbb -- -- 32 V
Reverse battery voltage drop (Vout > Vbb)
IL = -5 A T
j=150 °C:
-VON(rev)
--
600 -- mV
Diagnostic Characteristics
Current sense ratio9), static on-condition,
VIS = 0...5 V, Vbb(on) = 6.510)...27V,
kILIS = IL / IIS Tj = -40°C, IL = 5 A:
kILIS
4550
5000 6000
Tj= -40°C, IL= 0.5 A: 3300 5000 8000
Tj= 25...+150°C, IL= 5 A:
, Tj= 25...+150°C, IL = 0.5 A:
4550
4000
5000
5000
5550
6500
Current sense output voltage limitation
Tj = -40 ...+150°C IIS = 0, IL = 5 A:
VIS(lim)
5.4
6.1 6.9 V
Current sense leakage/offset current
Tj = -40 ...+150°C VIN=0, VIS = 0, IL = 0:
IIS(LL)
0
-- 1µA
VIN=5 V, VIS = 0, IL = 0: IIS(LH) 0 -- 15
VIN=5 V, VIS = 0, VOUT = 0 (short circuit): IIS(SH)11 ) 0 -- 10
7) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
8) Requires 150 resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 8).
9) This range for the current sense ratio refers to all devices. The accuracy of the kILIS can be raised at least by
a factor of two by matching the value of kILIS for every single device.
In the case of current limitation the sense current IIS is zero and the diagnostic feedback potential VST is
High. See figure 2b, page 10.
10) Valid if Vbb(u rst) was exceeded before.
11) not subject to production test, specified by design
PROFET® ITS 640S2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, Vbb = 12 V unless otherwise specified min typ max
Infineon Technologies AG Page 6 2006-Mar-28
Current sense settling time to IIS static±10% after
positive input slope12) , IL = 0 5 A,
Tj= -40...+150°C
tson(IS)
--
-- 300 µs
Current sense settling time to 10% of IIS static after
negative input slope13) , IL = 5 0 A ,
Tj= -40...+150°C
tsoff(IS)
--
30 100 µs
Current sense rise time (60% to 90%) after change
of load current13) , IL = 2.5 5 A
tslc(IS)
--
10 -- µs
Open load detection voltage13) (off-condition)
Tj=-40..150°C:
VOUT(OL) 2 3 4V
Internal output pull down
(pin 6 to 2), VOUT=5 V, Tj=-40..150°C
RO
5
15 40 k
Input and Status Feedback14)
Input resistance
see circuit page 7
RI 3,0 4,5 7,0 k
Input turn-on threshold voltage Tj =-40..+150°C:VIN(T+) -- -- 3.5 V
Input turn-off threshold voltage Tj =-40..+150°C:VIN(T-) 1.5 -- -- V
Input threshold hysteresis VIN(T) -- 0.5 -- V
Off state input current (pin 3), VIN = 0.4 V
Tj =-40..+150°C
IIN(off)
1
-- 50 µA
On state input current (pin 3), VIN = 5 V
Tj =-40..+150°C
IIN(on)
20
50 90 µA
Delay time for status with open load
after Input neg. slope (see diagram page 12)
td(ST OL3)
--
400 -- µs
Status delay after positive input slope13)
T
j=-40 ... +150°C:
tdon(ST)
--
13 -- µs
Status delay after negative input slope13)
T
j=-40 ... +150°C:
tdoff(ST)
--
1 -- µs
Status output (open drain)
Zener limit voltage T
j =-40...+150°C, IST = +1.6 mA:
ST low voltage Tj =-40...+25°C, IST = +1.6 mA:
T
j = +150°C, IST = +1.6 mA:
VST(high)
VST(low)
5.4
--
--
6.1
--
--
6.9
0.4
0.7
V
Status leakage current, VST = 5 V, Tj=25 ... +150°C: IST(high) -- -- 2 µA
12) not subject to production test, specified by design
13) External pull up resistor required for open load detection in off state.
14) If a ground resistor RGND is used, add the voltage drop across this resistor.
PROFET® ITS 640S2
Infineon Technologies AG Page 7 2006-Mar-28
Truth Table
Input Output Status Current
Sense
level level level IIS
Normal
operation
L
H
L
H
H
L
0
nominal
Current-
limitation
L
H
L
H
H
H
0
0
Short circuit to
GND
L
H
L
L15)
H
H
0
0
Over-
temperature
L
H
L
L
H
H
0
0
Short circuit to
Vbb
L
H
H
H
L16)
L
0
<nominal 17)
Open load L
H
L18)
H
H (L19))
L
0
0
Undervoltage L
H
L
L
H
L
0
0
Overvoltage L
H
L
L
H
L
0
0
Negative output
voltage clamp
L L H 0
L = "Low" Level X = don't care Z = high impedance, potential depends on external circuit
H = "High" Level Status signal after the time delay shown in the diagrams (see fig 5. page 11...12)
15) The voltage drop over the power transistor is Vbb-VOUT>typ.3V. Under this condition the sense current IIS is
zero
16) An external short of output to Vbb, in the off state, causes an internal current from output to ground. If RGND
is used, an offset voltage at the GND and ST pins will occur and the VST low signal may be errorious.
17) Low ohmic short to Vbb may reduce the output current IL and therefore also the sense current IIS.
18) Power Transistor off, high impedance
19) with external resistor between pin 4 and pin 6&7
Terms
PROFET
V
IS
ST
OUT
GND
bb
VST
VIN
IST
IIN
Vbb
Ibb
IGND
6
2
4
3
5
IN
VIS
IIS
VOUT
V
ON
IL
OUT
17
RGND
Input circuit (ESD protection)
IN
GND
I
R
ESD-ZD
I
I
I
The use of ESD zener diodes as voltage clamp at DC
conditions is not recommended.
PROFET® ITS 640S2
Infineon Technologies AG Page 8 2006-Mar-28
Status output
ST
GND
ESD-
ZD
+5V
RST(ON)
ESD-Zener diode: 6.1 V typ., max 5 mA;
RST(ON) < 440 at 1.6 mA, The use of ESD zener
diodes as voltage clamp at DC conditions is not
recommended.
Current sense output
IS
GND
IS
R
IS
I
ESD-ZD
IS
V
ESD-Zener diode: 6.1 V typ., max 14 mA;
RIS = 1 k nominal
Inductive and overvoltage output clamp
+ Vbb
OUT
GND PROFET
VZ
VON
VON clamped to 47 V typ.
Overvoltage protection of logic part
+ Vbb
IS
ST
R
GND
GND
R
Signal GND
Logic
VZ2
IN
RI
VZ1
ST
IS
R
+ 5V
V
R
VZ1 = 6.1 V typ., VZ2 = 47 V typ., RI= 4 k typ,
RGND= 150 Ω, RST= 15 k, RIS= 1 k, RV= 15 k,
Reverse battery protection
GND
Logic
IS
ST
R
IN
ST
IS
R
+ 5V
V
R
OUT
L
R
Power GND
GND
R
Signal GND
Power
Inverse
I
R
Vbb
-
Diode
Z1
V
The load RL is inverse on, temperature protection is
not active
RGND= 150 Ω, RI= 4 k typ, RST 500 , RIS 200 ,
RV 500 ,
Open-load detection
OFF-state diagnostic condition: VOUT > 3 V typ.; IN low
Logic
ST
Out VOUT
Signal GND
REXT
RO
OFF
Vbb
PROFET® ITS 640S2
Infineon Technologies AG Page 9 2006-Mar-28
GND disconnect
PROFET
V
ST
IS
OUT
GND
bb
Vbb
Ibb
6
2
4
3
5
IN
OUT
1
7
VIN V
ST V
IS V
GND
Any kind of load. In case of Input=high is VOUT VIN - VIN(T+) .
Due to VGND >0, no VST = low signal available.
GND disconnect with GND pull up
PROFET
V
ST
IS
OUT
GND
bb
Vbb
6
2
4
3
5
IN
OUT
1
7
VIN VSTVIS VGND
Any kind of load. If VGND > VIN - VIN(T+) device stays off
Due to VGND >0, no VST = low signal available.
Vbb disconnect with energized inductive
load
PROFET
V
ST
IS
OUT
GND
bb
Vbb
6
2
4
3
5
IN
OUT
1
7
high
Normal load current can be handled by the PROFET
itself.
Vbb disconnect with charged external
inductive load
PROFET
V
ST
IS
OUT
GND
bb
6
2
4
3
5
IN
OUT
1
7
Vbb
high
D
RL
L
If other external inductive loads L are connected to the PROFET,
additional elements like D are necessary.
Inductive Load switch-off energy
dissipation
PROFET
IN
ST
OUT
GND
Vbb
=
E
E
E
EAS
bb
L
R
ELoad
IS
1
2
5
3
4
6
7
OUT
Vbb
Energy stored in load inductance:
EL = 1/2·L·I2
L
While demagnetizing load inductance, the energy
dissipated in PROFET is
EAS= Ebb + EL - ER= VON(CL)·iL(t) dt,
with an approximate solution for RL > 0 :
EAS= IL· L
2·RL·(Vbb + |VOUT(CL)|)· ln (1+ IL·RL
|VOUT(CL)| )
PROFET® ITS 640S2
Infineon Technologies AG Page 10 2006-Mar-28
Timing diagrams
Figure 1a: Switching a resistive load,
change of load current in on-condition:
IN
ST
OUT
L
t
V
I
IIS
tson(IS)
tt
slc(IS)slc(IS)
Load 1 Load 2
soff(IS)
t
tdon(ST) tdoff(ST)
tt
on off
The sense signal is not valid during settling time after turn or
change of load current.
Figure 1b: Vbb turn on:
IN
V
L
t
I
bb
ST
IIS
proper turn on under all conditions
Figure 2a: Switching a lamp
IN
ST
OUT
L
t
V
I
IIS
Figure 2b: Switching a lamp with current limit:
IN
ST
OUT
L
t
V
I
IIS
PROFET® ITS 640S2
Infineon Technologies AG Page 11 2006-Mar-28
Figure 2c: Switching an inductive load:
IN
ST
t
V
I
OUT
L
IIS
Figure 3a: Short circuit:
shut down by overtempertature, reset by cooling
IN
ST t
I
L(SCr)
I
IL(SCp)
IIS
L
Heating up may require several milliseconds, depending on
external conditions
IL(SCp) = 50 A typ. increases with decreasing temperature.
Figure 4a: Overtemperature:
Reset if Tj <Tjt
ST
J
t
T
IN
IL
IIS
Figure 5a: Open load: detection in ON-state,
open load occurs in on-state
IN
ST
OUT
L
t
V
I
opennormal normal
IIS
PROFET® ITS 640S2
Infineon Technologies AG Page 12 2006-Mar-28
Figure 5b: Open load: detection in ON- and OFF-state
(with REXT), turn on/off to open load
IN
ST
OUT
t
V
I
open load
L
IIS
d(ST OL3)
t
Figure 6a: Undervoltage:
IN
V
t
bb
ST
VV
bb(under) bb(u cp)
V
IL
IIS
bb(u rst)
not defined
Figure 6b: Undervoltage restart of charge pump
bb(under)
V
Vbb(u rst)
Vbb(over)
Vbb(o rst)
Vbb(u cp)
off-state
on-state
V
ON(CL)
Vbb
Von
off-state
charge pump starts at Vbb(ucp) =4.7 V typ.
Figure 7a: Overvoltage:
IN
V
t
bb
ST
ON(CL)
VVbb(over) Vbb(o rst)
IL
IIS
PROFET® ITS 640S2
Infineon Technologies AG Page 13 2006-Mar-28
Figure 8a: Current sense versus load current:
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
0123456
IL
[A]
[mA] IIS
Figure 8b: Current sense ratio20:
0
5000
10000
15000
012345678910111213
IL
[A]
kILIS
20 This range for the current sense ratio refers to all
devices. The accuracy of the kILIS can be raised at
least by a factor of two by matching the value of
kILIS for every single device.
Figure 9a: Output voltage drop versus load current:
0.0
0.1
0.2
012345678
IL
[A]
[V] VON
ON(NL)
V
ON
R
PROFET® ITS 640S2
Infineon Technologies AG Page 14 2006-Mar-28
Package and Ordering Code
All dimensions in mm
Standard (=staggered): PG-TO220-7-11
Sales code ITS640S2
Ordering code SP000221217
Straight: PG-TO220-7-12
Sales Code ITS640S2 S
Ordering code SP000221225
Published by
Infineon Technologies AG,
St.-Martin-Strasse 53,
D-81669 München
© Infineon Technologies AG 2006
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and
shall not be considered as a guarantee of characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited
to warranties of non-infringement, regarding circuits, descriptions
and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and conditions
and prices please contact your nearest Infineon Technologies Office
in Germany or our Infineon Technologies Representatives worldwide
(see address list).
Warnings
Due to technical requirements components may contain dangerous
substances. For information on the types in question please contact
your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support
devices or systems with the express written approval of Infineon
Technologies, if a failure of such components can reasonably be
expected to cause the failure of that life-support device or system,
or to affect the safety or effectiveness of that device or system. Life
support devices or systems are intended to be implanted in the
human body, or to support and/or maintain and sustain and/or
protect human life. If they fail, it is reasonable to assume that the
health of the user or other persons may be endangered.
Typical
±0.11.27 4.4
9.25
±0.2
0.05
1)
All metal surfaces tin plated, except area of cut.
C
2.4 0.5±0.1
±0.3
8.6
10.2
±0.3
±0.43.9
±0.48.4
3.7
±0.3
A
A0.25 M
9.8±0.15
2.8
1)
15.65
±0.3
13.4
0...0.15
1.27 0.6±0.1
C
±0.2
17
±0.3
8.51)
10±0.2
3.7-0.15
7x
A
BA0.25
M
Typical
9.8
±0.15
2.8
1)
15.65±0.3
13.4
0...0.15
1.27 0.6
±0.1
±0.1
1.27 4.4
B
9.25±0.2
0.05
1)
All metal surfaces tin plated, except area of cut.
C
±0.2
17±0.3
8.5
1)
10
±0.2
3.7
-0.15
C
2.4 0.5
±0.1
13±0.5
±0.511
7x