Circuit Protection Solutions Product Information C o n t e n t s / I n t ro d u c t i o n Page Branch Rated Circuit Protection 9926 Series--AC Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 9926 Series--AC Version with Auxiliary and Alarm Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 9926 Series--DC Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Supplemental Circuit Protection 9926 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 9926 Series with Auxiliary and Alarm Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 9926 Series--Ground Fault Current Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 9926 Series--Mounting Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CB4200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 CB2200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 CB9100 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Weidmuller's DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short circuits. Each circuit breaker has the ability to be reset without the need to change components. All circuit breakers are available with an assortment of jumpers and marking tags. Circuit breakers in the 9926 Series are UL 489 Listed and CSA Certified as branch rated protection devices under CSA 22.2 No. 5-02. The hydraulic magnetic trip mechanism offers 10,000A of interrupting capacity in 120V and 240V, 50/60Hz applications. The CB4200 Series of thermal magnetic circuit breakers feature a pushbutton style of trip reset. This reset provides a visual indication of status which allows for rapid troubleshooting. 2 9926 Series The CB2200 Series feature integrated alarm contacts within a narrow profile, thereby allowing increased enclosure capacity. All of these circuit breakers demonstrate consistent reliability through 100% calibration and testing, and feature a touch safe design to prevent injury from accidental contact with live components. CB2200 Series The CB9100 Series of thermal magnetic circuit breakers provide a rugged and industry-standard form factor (18 mm/pole). For supplemental circuit protection. CB4200 Series CB9100 Series 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s - A C Ve r s i o n Circuit Breakers Hydraulic Magnetic Type 9926 Series Double Pole Single pole and double pole versions 120/240 VAC, 50/60 Hz Up to 25A Just 13 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering Data Technical Data Voltage Current Type: Single Pole Current Ratings (amps) Part No. TS 35 0.5 1 Description Part No. TS 35 Description 9926251000 9926251001 QL-1-13-DM-KM-0.5 QL-1-13-DM-KM-01 0.5 1 9926252000 9926252001 QL-2-13-DM-KM-0.5 QL-2-13-DM-KM-01 2 9926251002 QL-1-13-DM-KM-02 2 9926252002 QL-2-13-DM-KM-02 3 4 9926251003 9926251004 QL-1-13-DM-KM-03 QL-1-13-DM-KM-04 3 4 9926252003 9926252004 QL-2-13-DM-KM-03 QL-2-13-DM-KM-04 5 6 9926251005 9926251006 QL-1-13-DM-KM-05 QL-1-13-DM-KM-06 5 6 9926252005 9926252006 QL-2-13-DM-KM-05 QL-2-13-DM-KM-06 7 9926251007 QL-1-13-DM-KM-07 7 9926252007 QL-2-13-DM-KM-07 8 10 13 15 16 9926251008 9926251010 9926251013 9926251015 9926251016 QL-1-13-DM-KM-08 QL-1-13-DM-KM-10 QL-1-13-DM-KM-13 QL-1-13-DM-KM-15 QL-1-13-DM-KM-16 8 10 13 15 16 9926252008 9926252010 9926252013 9926252015 9926252016 QL-2-13-DM-KM-08 QL-2-13-DM-KM-10 QL-2-13-DM-KM-13 QL-2-13-DM-KM-15 QL-2-13-DM-KM-16 20 25 9926251020 9926251025 QL-1-13-DM-KM-20 QL-1-13-DM-KM-25 20 25 9926252020 9926252025 QL-2-13-DM-KM-20 QL-2-13-DM-KM-25 9926 Series AC Version - dimensions in mm (in.) 120/240 VAC, 50/60Hz 0.5A 25A 66 (2.6) 5 (0.2) Additional trip curves and amp ratings are available upon request. Minutes Tripping Time 10 0.01 0.001 0.001 (%) Rated Current 4000 5000 0.01 2000 2500 3000 0.1 1500 Seconds 1 1000 Although the 9926 series uses a magnetic only trip mechanism, CSA testing indicates a trip characteristic similar to thermal magnetic trip mechanisms. No de-rating is required at elevated temperatures. 1 300 0.4 0.1 Ambient Temperature 30C 10 100 105 125 150 200 0.6 1 4000 5000 1.5 10 2000 2500 3000 4 1 1500 28 10 1000 125% 150% 200% 400% 600% 800% 1000% minimum 15 8 4 0.7 0.09 0.007 0.005 (sec) 100 Ambient Temperature 30C 400 500 Sample trip characteristics - KM Tripping Time Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C Operating Characteristics Curve KM Operating Characteristics Curve 1 100 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. 9926 Series-AC version Trip Curve 1000 1000 400 500 9926 Series-AC version Trip Curve 67101960 67101961 67101913 The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. 45 (1.77) 64.8 (2.55) Minutes Power lug, straight Power lug, 90 Lock-out handle 13 (0.51) 32 (1.26) 100 105 130 150 200 67101904 67101972 67101973 67101974 19 (0.75) Seconds (1 pole, insulated, 1 m) (2 pole, insulated, 1 m) end cap, 1 pole end cap, 2 pole 92.8 (3.65) 57 (2.24) 71.4 (2.81) 100MM 10000 mechanical operations -40...+65C 0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. Torque 20 in.-lb Approval UL 489 listed, CSA C22.2 No. 5-02, CE, VDE Accessories Part No. 90 26 (1.02) 10,000A 1500V, 50/60Hz Insulation resistance Operating life Operating temperature Wire size* maximum 300 (sec) 13 (0.51) 28.5 (1.12) Interrupting capacity Dielectric strength 17.9 (0.7) 74 (2.91) minimum maximum Bus-bar Bus-bar Bus-bar Bus-bar Type: Double Pole Current Ratings (amps) 300 * * * * * * * 9926 Series Single Pole (%) Rated Current Trip Curve 1 applies to the following part numbers where "XX" is the current rating: Single Pole-- 99262512XX Double Pole-- 99262522XX 3 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s - A C Ve r s i o n w i t h C o n t a c t s Circuit Breakers with Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact) * AC voltages (120/240V) * Single and double pole versions * UL 489 and CSA listed * Factory fitted auxiliary or trip alarm * Compact 6.5mm width * Attached to right hand side of circuit breaker Technical Data Type: Single Pole Aux Voltage 120/240 VAC, 50/60Hz Current minimum maximum Interrupting capacity Current Ratings (amps) Part No. 1 9926261001 2 9926261002 5 9926261005 10 9926261010 15 9926261015 20 9926261020 25 9926261025 0.5A 25A 10,000A Dielectric strength Insulation resistance Operating life 1500V, 50/60Hz 100MM 10000 mechanical operations Operating temperature -40...+65C Wire size* 0.5-15A: 20-25A: Torque 14AWG min., 10AWG max. 10AWG min. 20 in.-lb Description QL-A-1-13-DM-KM-1 QL-A-1-13-DM-KM-2 QL-A-1-13-DM-KM-5 QL-A-1-13-DM-KM-10 QL-A-1-13-DM-KM-15 QL-A-1-13-DM-KM-20 QL-A-1-13-DM-KM-25 Current Ratings (amps) Part No. 1 9926281001 2 9926281002 5 9926281005 10 9926281010 15 9926281015 20 9926281020 25 9926281025 Description QL-T-1-13-DM-KM-1 QL-T-1-13-DM-KM-2 QL-T-1-13-DM-KM-5 QL-T-1-13-DM-KM-10 QL-T-1-13-DM-KM-15 QL-T-1-13-DM-KM-20 QL-T-1-13-DM-KM-25 9926 Series Double Pole Trip (Alarm Contact) 9926 Series Double Pole w/ Auxiliary Contact Approval UL 489 listed, CSA C22.2 No. 5-02, CE, VDE Type: Single Pole Combo Type: Single Pole Trip Current Ratings (amps) Part No. 1 9926271001 2 9926271002 5 9926271005 10 9926271010 15 9926271015 20 9926271020 25 9926271025 Description QL-AT-1-13-DM-KM-1 QL-AT-1-13-DM-KM-2 QL-AT-1-13-DM-KM-5 QL-AT-1-13-DM-KM-10 QL-AT-1-13-DM-KM-15 QL-AT-1-13-DM-KM-20 QL-AT-1-13-DM-KM-25 9926 Series Double Pole Combination (Auxiliary & Alarm Contact) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Type: Double Pole Aux Current Ratings (amps) Part No. 1 9926262001 2 9926262002 5 9926262005 10 9926262010 15 9926262015 20 9926262020 25 9926262025 Type: Double Pole Trip Description QL-A-2-13-DM-KM-1 QL-A-2-13-DM-KM-2 QL-A-2-13-DM-KM-5 QL-A-2-13-DM-KM-10 QL-A-2-13-DM-KM-15 QL-A-2-13-DM-KM-20 QL-A-2-13-DM-KM-25 1000 Operating Characteristics Curve KM 9926272005 QL-T-2-13-DM-KM-5 9926272010 QL-T-2-13-DM-KM-10 9926272015 QL-T-2-13-DM-KM-15 9926272020 QL-T-2-13-DM-KM-20 9926272025 QL-T-2-13-DM-KM-25 31.3 (1.23) 26.2 (1.03) (N/O)16 (N/C)18 (C)15 Ambient Temperature 30C TRIP ALARM Q. CONNECTORS 21.1 (0.83) 10 5.5 (0.22) 0.5 (0.02) Tripping Time Minutes 100 57.0 (2.24) 1 10 14(N/O) 21.3 (0.84) (%) Rated Current 4000 5000 2000 2500 3000 1500 1000 400 500 300 0.001 32.9 (1.3) 10.7 (0.42) 0.5 (0.02) 0.1 100 105 125 150 200 7 (0.28) 2.8 (0.11) 11(C) Seconds 12(N/C) AUX SWITCH Q. CONNECTORS 1 0.01 4 Part No. Description 9926272001 QL-T-2-13-DM-KM-1 9926272002 QL-T-2-13-DM-KM-2 Dual Mount Dimensions in mm (in.) Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C Additional trip curves and amp ratings are available upon request. Type: Double Pole Combo Current Ratings (amps) Part No. 1 9926282001 2 9926282002 5 9926282005 10 9926282010 15 9926282015 20 9926282020 25 9926282025 2 (0.08) 9926 Series-AC version Trip Curve Current Ratings (amps) 1 2 5 10 15 20 25 Description QL-AT-2-13-DM-KM-1 QL-AT-2-13-DM-KM-2 QL-AT-2-13-DM-KM-5 QL-AT-2-13-DM-KM-10 QL-AT-2-13-DM-KM-15 QL-AT-2-13-DM-KM-20 QL-AT-2-13-DM-KM-25 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s - D C Ve r s i o n Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole (80 VDC) 9926 Series Single Pole (125 VDC) * Single pole versions only * U2 trip curve for general purpose applications * 80 and 125 VDC * Up to 60A * Just 13 mm wide * Mounts on 35mm DIN-rail * UL 489A listed * VDE Type: Single Pole (80 VDC) Current Ratings (amps) 0.5 1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 Accessories Part No. 9926251900 Description QY-1-13-DM-U2-0.5 9926251901 9926251902 QY-1-13-DM-U2-01 QY-1-13-DM-U2-02 9926251903 9926251904 9926251905 QY-1-13-DM-U2-03 QY-1-13-DM-U2-04 QY-1-13-DM-U2-05 9926251910 9926251915 QY-1-13-DM-U2-10 QY-1-13-DM-U2-15 9926251920 9926251925 9926251930 9926251935 9926251940 9926251945 9926251950 QY-1-13-DM-U2-20 QY-1-13-DM-U2-25 QY-1-13-DM-U2-30 QY-1-13-DM-U2-35 QY-1-13-DM-U2-40 QY-1-13-DM-U2-45 QY-1-13-DM-U2-50 9926251960 QY-1-13-DM-U2-60 9926 Series-DC version Trip Curve QY-1-13-DM-U2-05-B1 9926251810 QY-1-13-DM-U2-10-B1 9926251815 9926251820 9926251825 9926251830 9926251835 QY-1-13-DM-U2-15-B1 QY-1-13-DM-U2-20-B1 QY-1-13-DM-U2-25-B1 QY-1-13-DM-U2-30-B1 QY-1-13-DM-U2-35-B1 9926251840 9926251845 9926251850 9926251860 QY-1-13-DM-U2-40-B1 QY-1-13-DM-U2-45-B1 QY-1-13-DM-U2-50-B1 QY-1-13-DM-U2-60-B1 74 (2.91) 66 (2.6) 13 (0.51) 92.8 (3.65) 28.5 (1.12) 57 (2.24) Minutes Ambient Temperature 30C 1 10 19 (0.75) 1 32 (1.26) 0.1 5 (0.2) 45 (1.77) 64.8 (2.55) 0.01 4000 5000 0.001 300 10,000 A 1500 V, 50/60 Hz 100 MM 10000 mechanical operations Operating temperature -40...+65C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval UL 489A Listed, CE, VDE 9926251805 10 100 105 130 150 200 Interrupting capacity Dielectric strength Insulation resistance Operating life Tripping Time 80,125 VDC 0.5 A 60 A QY-1-13-DM-U2-02-B1 QY-1-13-DM-U2-03-B1 QY-1-13-DM-U2-04-B1 Dimensions in mm (in.) Operating Characteristics Curve U2 DC (4% Ripple Factor) 100 Seconds minimum maximum 9926251802 9926251803 9926251804 71.4 (2.81) 1000 Technical Data 2000 2500 3000 67101913 1500 Lock-out handle Description QY-1-13-DM-U2-01-B1 Additional trip curves and amp ratings are available upon request. 1000 Part No. 67101904 67101973 67101960 67101961 Part No. 9926251801 Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C 400 500 Type Bus-bar (1 pole, insulated 1m) Bus bar end cap, 1 pole Power lug, straight Power lug, 90 Voltage Current Type: Single Pole (125 VDC) Current Ratings (amps) 1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 17.9 (0.7) Ordering Data (%) Rated Current *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. 5 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole 9926 Series Double Pole 9926 Series Triple Pole * AC Voltages 240/480V * Trip curve 2 for general purpose applications * UL 1077 recognized * VDE, CSA, and CE Approved * Just 13 mm wide * Mounts to 35 mm DIN-rail * Factory fitted auxiliary or trip alarm * Single, double and triple pole versions Ordering Data Type: Single Pole Current Ratings (amps) 1 2 3 4 5 6 8 10 15 20 25 35 40 50 60 Accessories Part No. Description 9926251501 9926251502 QZ-1-13-D-2-01 QZ-1-13-D-2-02 9926251503 QZ-1-13-D-2-03 9926251504 9926251505 QZ-1-13-D-2-04 QZ-1-13-D-2-05 9926251506 9926251508 9926251510 9926251515 9926251520 QZ-1-13-D-2-06 QZ-1-13-D-2-08 QZ-1-13-D-2-10 QZ-1-13-D-2-15 QZ-1-13-D-2-20 9926251525 9926251535 9926251540 9926251550 9926251560 QZ-1-13-D-2-25 QZ-1-13-D-2-35 QZ-1-13-D-2-40 QZ-1-13-D-2-50 QZ-1-13-D-2-60 Part No. Description 9926252501 9926252502 QZ-2-13-D-2-01 QZ-2-13-D-2-02 9926252504 QZ-2-13-D-2-04 9926252505 9926252506 QZ-2-13-D-2-05 QZ-2-13-D-2-06 9926252510 9926252515 9926252520 9926252525 9926252530 QZ-2-13-D-2-10 QZ-2-13-D-2-15 QZ-2-13-D-2-20 QZ-2-13-D-2-25 QZ-2-13-D-2-30 9926252535 9926252540 9926252550 9926252560 QZ-2-13-D-2-35 QZ-2-13-D-2-40 QZ-2-13-D-2-50 QZ-2-13-D-2-60 Part No. Description 9926253510 9926253515 QZ-3-13-D-2-10 QZ-3-13-D-2-15 9926253520 QZ-3-13-D-2-20 9926253525 9926253530 QZ-3-13-D-2-25 QZ-3-13-D-2-30 9926253540 9926253550 9926253560 QZ-3-13-D-2-40 QZ-3-13-D-2-50 QZ-3-13-D-2-60 65 (2.56) 13 (0.51) 60 (2.36) 26 (1.02) 39 (1.54) 92.8 (3.65) 25.9 (0.94) 45 (1.77) 13 (0.51) 63.8 (2.51) 73 (2.87) Operating Characteristics Curve 2 Minutes 100 Ambient Temperature 30C 10 1 10 1 0.1 0.01 (%) Rated Current 4000 5000 2000 2500 3000 1500 1000 0.001 400 500 The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Additional trip curves and amp ratings are available upon request. 1000 300 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. 9926 Series-Supplemental Trip Curve Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C 100 105 130 150 200 Technical Data Voltage 277/480 VAC @ 50/60 Hz Current minimum 0.5 A maximum 60 A Interrupting capacity 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength 1500 V, 50/60 Hz Insulation resistance 100 MM Operating life 10000 mechanical operations Operating temperature -40...+65C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval UL 1077 Recognized, VDE (EN 60947-2), CSA C22.2 No. 235, CE Approved Tripping Time 5.0 (0.2) 13 (0.51) Seconds Part No. 67101904 67101972 67101971 67101973 67101974 67101960 67101961 67101913 44 (1.73) 6 Type: Triple Pole Current Rating (amps) 10 15 20 25 30 40 50 60 9926 Series Supplemental - dimensions in mm (in.) 22.5 (0.86) Type Bus bar (1 pole, insulated 1m) Bus bar (2 pole, insulated 1m) Bus bar (3 pole, insulated 1m) Bus bar end cap, 1 pole Bus bar end cap, 2 pole or 3 pole Power lug, straight Power lug, 90 Lock-out handle Type: Double Pole Current Rating (amps) 1 2 4 5 6 10 15 20 25 30 35 40 50 60 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s w i t h C o n t a c t s Circuit Breakers Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact) * AC Voltages 240/480V * Trip curve 2 for general purpose applications * UL 1077 recognized * VDE, CSA, and CE Approved * Just 13 mm wide * Mounts to 35 mm DIN-rail * Factory fitted auxiliary or trip alarm * Single, double and triple pole versions Type: Single Pole Aux Technical Data Voltage 277/480 VAC @ 50/60 Hz Current minimum 0.5 A maximum 60 A Interrupting capacity 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength Insulation resistance Operating life 1500 V, 50/60 Hz 100 MM 10000 mechanical operations Operating temperature -40...+65C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval UL 1077 Recognized, VDE (EN 60947-2), CSA C22.2 No. 235, CE Approved Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926261501 9926261502 Description QZ-A-1-13-D-2-01 QZ-A-1-13-D-2-02 9926261505 9926261510 QZ-A-1-13-D-2-05 QZ-A-1-13-D-2-10 9926261515 9926261520 9926261525 QZ-A-1-13-D-2-15 QZ-A-1-13-D-2-20 QZ-A-1-13-D-2-25 9926 Series Double Pole w/ Auxiliary Contact Type: Single Pole Trip Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926271501 9926271502 Description QZ-T-1-13-D-2-01 QZ-T-1-13-D-2-02 9926271505 9926271510 QZ-T-1-13-D-2-05 QZ-T-1-13-D-2-10 9926271515 9926271520 9926271525 QZ-T-1-13-D-2-15 QZ-T-1-13-D-2-20 QZ-T-1-13-D-2-25 9926 Series Double Pole Trip (Alarm Contact) Type: Single Pole Combo Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926281501 9926281502 Description QZ-AT-1-13-D-2-01 QZ-AT-1-13-D-2-02 9926281505 9926281510 QZ-AT-1-13-D-2-05 QZ-AT-1-13-D-2-10 9926281515 9926281520 9926281525 QZ-AT-1-13-D-2-15 QZ-AT-1-13-D-2-20 QZ-AT-1-13-D-2-25 9926 Series Double Pole Combination (Auxiliary & Alarm Contact) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags.The part number for adhesive SchS2 is 1720600000. 9926 Series-Supplemental Trip Curve Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C 1000 Operating Characteristics Curve 2 Type: Double Pole Aux Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926262501 9926262502 9926262505 Description QZ-A-2-13-D-2-01 QZ-A-2-13-D-2-02 QZ-A-2-13-D-2-05 9926262510 QZ-A-2-13-D-2-10 9926262515 9926262520 QZ-A-2-13-D-2-15 QZ-A-2-13-D-2-20 9926262525 QZ-A-2-13-D-2-25 Type: Double Pole Trip Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926272501 9926272502 9926272505 Description QZ-T-2-13-D-2-01 QZ-T-2-13-D-2-02 QZ-T-2-13-D-2-05 9926272510 QZ-T-2-13-D-2-10 9926272515 9926272520 QZ-T-2-13-D-2-15 QZ-T-2-13-D-2-20 9926272525 QZ-T-2-13-D-2-25 Type: Double Pole Combo Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926282501 9926282502 9926282505 Description QZ-AT-2-13-D-2-01 QZ-AT-2-13-D-2-02 QZ-AT-2-13-D-2-05 9926282510 QZ-AT-2-13-D-2-10 9926282515 9926282520 QZ-AT-2-13-D-2-15 QZ-AT-2-13-D-2-20 9926282525 QZ-AT-2-13-D-2-25 Tripping Time Minutes 100 Ambient Temperature 30C 10 9926 Series Triple Pole w/ Auxiliary Contact 1 10 9926 Series Triple Pole Trip ( Alarm Contact) 9926 Series Triple Pole Combination (Auxiliary & Alarm Contact) Seconds 1 0.1 0.01 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 Type: Triple Pole Aux (%) Rated Current Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926263501 9926263502 9926263505 9926263510 9926263515 Description QZ-A-3-13-D-2-01 QZ-A-3-13-D-2-02 QZ-A-3-13-D-2-05 QZ-A-3-13-D-2-10 QZ-A-3-13-D-2-15 9926263520 9926263525 QZ-A-3-13-D-2-20 QZ-A-3-13-D-2-25 Type: Triple Pole Trip Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926273501 9926273502 9926273505 9926273510 9926273515 Description QZ-T-3-13-D-2-01 QZ-T-3-13-D-2-02 QZ-T-3-13-D-2-05 QZ-T-3-13-D-2-10 QZ-T-3-13-D-2-15 9926273520 9926273525 QZ-T-3-13-D-2-20 QZ-T-3-13-D-2-25 Type: Triple Pole Combo Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926283501 9926283502 9926283505 9926283510 9926283515 Description QZ-AT-3-13-D-2-01 QZ-AT-3-13-D-2-02 QZ-AT-3-13-D-2-05 QZ-AT-3-13-D-2-10 QZ-AT-3-13-D-2-15 9926283520 9926283525 QZ-AT-3-13-D-2-20 QZ-AT-3-13-D-2-25 7 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s - G F C I Ground Fault Current Interrupt Ordering Data QF17A2515 QF17A2520 QF17A2525 QF17A2530 QF17A2550 - CB CB CB CB CB W/GFI W/GFI W/GFI W/GFI W/GFI Trip Curves--Hydraulic Magnetic Type Typical time/current characteristics at 30C 1000 2 -40 to +65C Operating Characteristics Curve 2 Tripping Time Minutes 100 44 (1.73) Ambient Temperature 30C 10 68.8 (2.71) 1 10 26 (1.02) 1 Seconds Approval UL 1077 and UL 1053, CE 73 (2.87) 65 (2.56) 0.1 7.8 (0.307) 5 to 50A Sensitivity (mA) 30 (CE) / 22 (UL) Number of Poles 1+N Equipment Type Earth Leakage/GFCS Rated Voltage (V) 230 (CE) / 240 (UL) Rated Interrupting/ 5 kA Withstand Capacity (kA) - Weight (kg) 0.26 Trip Curve (standard) Operating Temperature Description QF17A2505 - CB W/GFI QF17A2510 - CB W/GFI 9926 Series-AC version Trip Curve Technical Data Standard Ampere Ratings (A) 9926 Series GFCI - dimensions in mm (in.) Type: Single Pole GFCI Current Ratings (amps) Part No. 5 9926291105 10 9926291110 15 9926291115 20 9926291120 25 9926291125 30 9926291130 50 9926291150 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 16.4 (0.646) 8.0 (0.315) 71.4 (2.81) 0.01 26 (1.02) * (2.24) * * 57 * CE approved UL1077 and UL1053 recognized Small frame size (26mm wide) Single pole plus switched neutral earth leakage protection Trip point is unaffected by ambient temperature Current ratings up to 50A Trip indication (mid trip handle position) Trip curve 2 for general purpose applications 93 (3.66) 82.4 (3.24) * * * * 9926 Series GFCI (%) Rated Current 35.7 (1.406) 8 9926 Series Mounting Options and Accessories Mounting Options 93% 95 ON OFF 95 OF F ON OF F ON 5 N VERT 45 W ON OFF 100% ON VERT D 4 O R 5 N HO IZ DO 4 W 10 ON OF F ON OF F % ON OF F 5% 100% HORIZ 4 5 OFF UP UP It is important to note that in environments that are exposed to a high degree of vibration, the cables that connect to the circuit breaker must be securely held in place, as the breaker is not designed to carry the weight of the cables. A maximum of 35N can be applied to the terminal area, in a direction perpendicular to the mounting axis. % % If the product is not vertically mounted in the normal DIN-rail mounting orientation, a rating factor must be applied. Figure 1 shows a diagram of the rating factor to apply. The published curves for these circuit breaker products are produced with the circuit breaker in the vertical mounting position. The rating factor only applies to the must hold and must trip points of the curve as the other parts (instantaneous trip point) stay largely unaffected. 10 5 107% Accessories Technical Data Part Number Table - Example Current Rating Voltage Short Circuit Strength 80A max. 500V max. 25kA Type Bus bar (1 pole, insulated 1m) Bus bar (2 pole, insulated 1m) Part No. 67101904 67101972 Bus bar (3 pole, insulated 1m) 67101971 To order 9926 Series Single Pole Circuit Breaker Part No. 9926251100 * Current Rating of 1.0 amp * Internal Resistance per Pole of 1.1 ohms * Trip Curve - M1, Medium (Standard) 9 9 2 6 2 5 1 0 0 0 Amperage Type Bus bar end cap, 1 pole Bus bar end cap, 2 pole or 3 pole Part No. 67101973 67101974 "00" - 0.5A "01" - 1A "02" - 2A / "60" - 60A Trip Curves "0" - Branch AC KM (Standard) "1" - Branch AC OP (Instantaneous) "2" - Branch AC 1 (Fast) "4" - Branch 80VDC 1 (Fast) "5" - Supplemental 2 (Standard) "6" - Branch 125VDC OP (Instantaneous) "7" - Branch 80VDC OP (Instantaneous) "8" - Branch 125VDC U2 (Standard) "9" - Branch 80VDC U2 (Standard) Poles Technical Data Current Rating Wire Size Dimensions 85A max. 10 AWG min., 4 AWG max. A: 6 mm B: 32 mm 1 Pole 2 Pole 3 Pole Type Type Power lug, straight Power lug, 90 Part No. 67101960 67101961 Type Lock-out handle Part No. 67101913 "5" - Base Breaker "6" - With Auxiliary Contact "7" - With Trip Alarm Contact "8" - Combo Aux/Trip Contact "9" - GFCI 9 C B 4 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB4200 Series Single Pole CB4200 Series Double Pole * Rated from 0.05 to 16.0 amps * Available in single or double pole configurations * Features a tease free design to reduce contact damage * Offers push button trip/reset function * Trip free design means the breaker cannot be held closed against a fault * Mounts on 32mm* or 35mm DIN-rail * UL 1077 recognized Ordering Data Type: Single Pole Current Ratings (amps) 0.05 Type: Double Pole Part No. TS 35 *For TS 32 Rail, see adapter below 9124083500 Current Ratings (amps) 0.05 Part No. TS 35 *For TS 32 Rail, see adapter below 9124223500 0.08 9124653500 0.08 9124233500 0.1 9104173500 0.1 9120353500 0.2 0.3 9104183500 9129813500 0.2 0.3 9124243500 9124263500 0.4 0.5 9124093500 9101003500 0.4 0.5 9124273500 9129583500 0.6 0.7 0.8 1.0 9124113500 9129563500 9101103500 9101203500 0.6 0.7 0.8 1.0 9124283500 9124293500 9129593500 9129613500 1.2 1.3 1.4 9101303500 9124123500 9124133500 1.2 1.3 1.4 9129623500 9124313500 9124323500 1.5 9101403500 1.5 9129633500 1.8 2.0 2.5 3.0 9124143500 9101503500 9101603500 9101703500 1.8 2.0 2.5 3.0 9124333500 9129643500 9129653500 9129663500 3.5 4.0 9124163500 9104353500 3.5 4.0 9124343500 9129713500 4.5 5.0 5.5 9124173500 9101803500 9107833500 4.5 5.0 5.5 9124353500 9129673500 9124363500 6.0 6.5 7.0 8.0 9103813500 9120043500 9104153500 9103003500 6.0 6.5 7.0 8.0 9124373500 9124383500 9124393500 9104673500 9.0 10.0 9104613500 9101903500 9.0 10.0 9124423500 9129683500 11.0 12.0 9124183500 9107843500 11.0 12.0 9124433500 9124443500 13.0 9124193500 13.0 9124453500 14.0 15.0 16.0 9107853500 9102003500 9124213500 14.0 15.0 16.0 9124463500 9129693500 9124473500 Trip Curves Thermal Magnetic Type Typical time/current characteristics at 23C CB4200 Series *Adapter foot - dimensions in mm (in.) M1+ M1+ 0.05 to 7.5 A 8 to 16 A 10,000 -30C +23C +55C 100 100 Trip time in seconds 1,000 Trip time in seconds 1,000 10 1 10 9102100000 1 TS32 adapter 0.1 0.1 0.01 0.01 0.001 0.001 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 10 20 -30C +23C +55C 50 70 100 (.787) 10,000 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 C B 4 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB4200 Series Single Pole Internal Wiring Diagram Dimensions in mm Internal Wiring Diagram CB4200 Series Double Pole Dimensions in mm Technical Data Rated voltage & current UL CSA VDE Creepage resistance Dielectric strength Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) Interrupting capacity; 4201 (UL 1077/EN 60934 PC1) Voltage Ratings AC 250 V, DC 65 V, 50/60 Hz AC 250 V, DC 65 V, 50/60 Hz Current Ratings 0.05...16 A 0.05...16 A AC 250 V, DC 65 V, 50/60 Hz PTI 600 to IEC 112 4,000 VAC; IEC 664 & 664 A > 100 MM (DC 500 V) 0.05...16 A 4201-10 0.05...0.8 A Maximum capacity Self-limiting 1...2 A 2.5...16 A Rated current 200 A 400 A Rated voltage Maximum capacity 0.05...2.0 A 2.0...16 A AC 250 V AC 250 V 200 A 200 A 20 A AC 125 V 400 A Typical life at 2 x rated current Shock Torque Vibration Temperature range 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea 1.2 Nm 5 g (57 to 500 Hz / 0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc -30C...+55C (-22F...+131F) Corrosion 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka Humidity Weight Wire size (UL) 240 hours at 95% RH, to IEC 68-2-3, Test Ca 60 g per pole #20...8 AWG solid/0.5...6 mm2 Accessories Jumpers Daisy Chain 50* Straight CQB** insulated Angled CQB** insulated Adapter foot (for TS 32 Rail) Marking Tags Note: Part numbers are shown for a single card of pre-printed tags numbered 1-50. Special print only Consecutive horizontal Consecutive vertical Type Part No. BDC 50 CQB 2 CQB 3 CQB 4 CQB 10 CQB 2 9970290000 9970560000 9970570000 9970580000 9970590000 9970600000 CQB 3 9970610000 CQB 4 CQB 10 MCBAF/TS 32 9970620000 9970630000 9102100000 WS 8/5 MC DEK 5/5 DEK 5/5 1640750000*** 0473460001 0473560001 Note: Resistive and inductive loads (0.05 - 16 A) *BDC will accommodate 20 A per pin, 20 A total **CQB will accommodate 18 A per pin, 18 A total; dedicated to 4201 Series ***Please specify horizontal or vertical print when ordering. Standard quantity = 144 tags per card. 11 C B 2 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB2200 Series Single Pole CB2200 Series Double Pole CB2200 Series Triple Pole * Rated from 0.1 to 32.0 amps * Available in single, double and triple pole configurations * Offers normally open (N/O) and normally closed (N/C) auxiliary contacts * Lever-switch trip/reset function * Mounts on 32mm or 35mm DIN-rail * UL 1077 recognized Ordering Data Type: Single Pole* Type: Double Pole Type: Triple Pole Current Ratings (amps) N/O Aux. Part No. Current Ratings (amps) N/O-N/C Part No. Current Ratings (amps) N/O-N/C Part No. 0.1 0.2 9911010005 9911020005 0.1 0.2 9912010003 9912020003 0.1 0.2 9913010003 9913020003 0.3 0.4 0.5 0.6 9911030005 9911040005 9911050005 9911060005 0.3 0.4 0.5 0.6 9912030003 9912040003 9912050003 9912060003 0.3 0.4 0.5 0.6 9913030003 9913040003 9913050003 9913060003 0.8 1.0 9911080005 9911100005 0.8 1.0 9912080003 9912100003 0.8 1.0 9913080003 9913100003 1.5 2.0 2.5 9911150005 9911200005 9911250005 1.5 2.0 2.5 9912150003 9912200003 9912250003 1.5 2.0 2.5 9913150003 9913200003 9913250003 3.0 4.0 5.0 6.0 8.0 9911300005 9911400005 9911500005 9911600005 9911800005 3.0 4.0 5.0 6.0 8.0 9912300003 9912400003 9912500003 9912600003 9912800003 3.0 4.0 5.0 6.0 8.0 9913300003 9913400003 9913500003 9913600003 9913800003 10 12 15 16 18 20 9921100005 9921120005 9921150005 9921160005 9921180005 9921200005 10 12 15 16 18 20 9922100003 9922120003 9922150003 9922160003 9922180003 9922200003 10 12 15 16 18 20 9923100003 9923120003 9923150003 9923160003 9923180003 9923200003 25 9921250005 32 9921320005 *All part numbers with N/O Auxiliary Contacts on each pole when the main breaker contact is open (in the OFF position) Ordering Data Type: Single Pole Type: Double Pole Type: Triple Pole All part numbers with N/C Auxiliary Contacts on each pole when the main breaker contact is open (in the OFF position) Current Ratings Current Ratings Current Ratings (amps) Part No. (amps) Part No. (amps) Part No. 0.1 9911010000 0.1 9912010000 0.1 9913010000 0.2 9911020000 0.2 9912020000 0.2 9913020000 0.3 9911030000 0.3 9912030000 0.3 9913030000 12 0.4 0.5 0.6 0.8 1.0 1.5 2.0 9911040000 9911050000 9911060000 9911080000 9911100000 9911150000 9911200000 0.4 0.5 0.6 0.8 1.0 1.5 2.0 9912040000 9912050000 9912060000 9912080000 9912100000 9912150000 9912200000 0.4 0.5 0.6 0.8 1.0 1.5 2.0 9913040000 9913050000 9913060000 9913080000 9913100000 9913150000 9913200000 2.5 9911250000 2.5 9912250000 2.5 9913250000 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 9911300000 9911400000 9911500000 9911600000 9911800000 9921100000 9921120000 9921150000 9921160000 9921180000 9921200000 9921250000 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 9912300000 9912400000 9912500000 9912600000 9912800000 9922100000 9922120000 9922150000 9922160000 9922180000 9922200000 9922250000 3.0 4.0 5.0 6.0 8.0 10 12 15 16 18 20 25 9913300000 9913400000 9913500000 9913600000 9913800000 9923100000 9923120000 9923150000 9923160000 9923180000 9923200000 9923250000 32 9921320000 32 9922320000 32 9923320000 C B 2 2 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB2200 Series Trip Curves--Thermal Magnetic Type Typical time/current characteristics at 23C CB2200 Series F1 0.1 to 32 A 10,000 -30C +23C +55C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 3 4 2 6 8 10 20 30 50 70 100 ...times rated current -M1 0.1 to 7.5 A 10,000 -30C AC +23C DC +23C +55C Dimensions in mm UL CSA VDE Auxiliary contacts Creepage resistance Dielectric strength Voltage Ratings 277 / 480 VAC (50/60 Hz); 65 VDC 277 / 480 VAC (50/60 Hz); 65 VDC 250 / 415 VAC / 65 VDC 250 VAC / 65 VDC, 1 A PTI 600 to IEC 112 3,000 VAC; IEC 664 & 664 A Current Ratings 0.1...32 A 0.1...32 A 0.001 0.05...0.8 A 6...32 A 250 / 415 VAC 250 / 415 VAC 400 A 800 A Interrupting capacity (UL 1077/EN 60934 PC1) Rated current 0.1...16 A 20...32 A 0.1...32 A Rated voltage 277 / 480 VAC 277 / 480 VAC 65 VDC Max. rupture capacity (3 times) 5000 A 2000 A 2000 A 3 4 6 8 10 20 30 50 70 100 8 to 32 A -30C AC +23C DC +23C +55C 1,000 100 10 DC 0.1 AC 0.01 0.001 .8 1 2 3 4 -T1 Part No. 9970290000 9986510000 9987360000 20 30 50 70 100 0.1 to 7.5 A 10,000 -30C +23C +55C 1,000 Trip time in seconds 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca Approximately 60 g per pole max 6 mm2...8 AWG max 1.5 mm2...14 AWG (Aux. contact) 6 8 10 ...times rated current -30...+60C (-22F...+140F) Daisy Chain 50 2 10,000 5,000 operations 25 g (11 ms) to IEC 68-2-27, Test Ea 0.6 (5.3) Auxiliary contact: 0.5 (4.4) 5 g (57 to 500 Hz / 0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc Type BDC 50, 20 A maximum 1 pole (CB2200) 2 pole (CB2200) .8 1 -M1 Rupture capacity (3 times) Accessories Jumpers Busbars DC AC ...times rated current > 100 MM (DC 500 V) Rated current Rated voltage Nm (lb. in.) 10 0.01 0.1...32 A Insulation resistance Interrupting capacity (VDE 0660, Part 101, P-2) Typical life at 2 x rated current Shock Torque Vibration Temperature range Corrosion Humidity Weight Wire size (UL) 10 0.1 Trip time in seconds Technical Data Rated voltage & current 100 T Trip time in seconds 1,000 100 10 0.1 0.01 Marking Tags 1 2 3 4 5 6 Note: Part numbers shown are for a single card of pre-printed tags numbered 1-50. Special print only Consecutive horizontal Consecutive vertical DEK 5/6 DEK 5/6 0490360000* 0468660001 DEK 5/6 0468760001 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current -T1 8 to 32 A 10,000 Note: Resistive and inductive loads (0.05 - 16 A) *Please specify horizontal or vertical print when ordering. -30C +23C +55C Trip time in seconds 1,000 100 10 1 0.1 0.01 0.001 .8 1 2 3 4 6 8 10 20 30 50 70 100 ...times rated current 13 C B 9 1 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Thermal Magnetic Type CB9100 Series Single Pole CB9100 Series Double Pole CB9100 Series Triple Pole * Rated from 0.5 to 63 amps * Available in single, double and triple pole configurations * Optional auxiliary contacts * Mounts on 35mm DIN-rail * UL and CSA approvals * CSA 277 VAC (1 pole) or 480 VAC (2 and 3 pole) * 50 VDC (0.5 A to 50 A) 1 pole * 110 VDC (0.5 A to 50 A) 2 pole Ordering Data Type: Single Pole Current Ratings (amps) 0.5 1.0 2.0 3.0 4.0 6.0 10.0 13.0 16 20 25 32 40 50 63 Type: Double Pole Part No. Current Ratings (amps) 9925350000 9925360000 9925380000 0.5 1.0 2.0 9925390000 9925400000 9925410000 Type: Triple Pole Part No. Current Ratings (amps) Part No. 9925650000 9925660000 9925680000 0.5 1.0 2.0 9925810000 9925820000 9925840000 3.0 4.0 6.0 9925690000 9925700000 9925710000 3.0 4.0 6.0 9925850000 9925860000 9925870000 9925430000 9929820000 9925440000 10.0 13.0 16 9925730000 9929830000 9925740000 10.0 13.0 16 9925890000 9929840000 9925900000 9925450000 9925460000 9925470000 9925480000 9925490000 20 25 32 40 50 9925750000 9925760000 9925770000 9925780000 9925790000 20 25 32 40 50 9925910000 9925920000 9925930000 9925940000 9925950000 9925500000 63 9925800000 63 9925960000 Trip Curves Thermal Magnetic Type Typical time/current characteristics at 23C CB9100 Series M1 0.5 to 6 A 10,000 M1 AC 10 to 40 A 10,000 23C 23C 100 100 1 Trip time in seconds 100 Trip time in seconds 1,000 Trip time in seconds 1,000 10 10 1 10 1 0.1 0.1 0.1 0.01 0.01 0.01 0.001 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 AC 63 A 23C 1,000 0.001 0.001 0.8 1 2 3 4 6 8 10 20 30 ... times rated current Note: "C" trip time characteristics according to VDE 064 A4/11.88 (9100 Series only) 14 M1 10,000 50 70 100 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 C B 9 1 0 0 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s CB9100 Series 70 45 18 54 44 36 59 1 pole 2 pole 6 3 pole 86 Dimensions in mm Internal Wiring Diagram Auxiliary Contact Modules Technical Data Rated voltage & current UL 1077 277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole) CSA C 22.2 No. 235 277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole) 91.4 VDE Creepage resistance Insulation resistance Interrupting capacity (UL 1077/EN 609334 PC1) 1 pole 80.6 PTI 250 to IEC 112 >100 MM at 500 VDC Current ratings 0.5...63 A Interrupting Rupture capacity (3X) 10,000 A (UL) Voltage 277 VAC/50 VDC 0.5...32 A 0.5...63 A 2,000 A (UL) 6,000 A (UL) 347 / 600 AC 50 VDC (1) pole 0.5...50 A 20,000/10,000 20 g (10 ms) 6,000 A (UL) 110 VDC (2) poles Mechanical/Electrical endurance Shock Torque 2 Nm Vibration Temperature range - operating 3 g (10 to 55 Hz) -25C...+55C (-13F to 131F) Weight Strip length Auxiliary contact rating Wire size - #22...12 AWG 1 pole (130 g); 2 pole (280 g); 3 pole (430 g) 12 mm Voltage AC 220/240 5.8 Type 3 pole bus, 3 pole bus, 3 pole bus, 1 pole bus, 1 pole bus, Accessories Jumpers 10 16 16 12 12 Current 5A x x x x x 1010 mm, buses (19) 3 phase groupings 210 mm, buses (4) 3 phase groupings 1010 mm, buses (19) 3 phase groupings 210 mm, buses 12 breakers 210 mm (insulated), buses 12 breakers 5 45.2 9 AC 277 3A DC 24 V 4A DC 60 V 1A DC220 V 0.4 A #18...2 AWG (line); #18...3 AWG (load) Wire size 44 44 69 Part No. 9970330000 9970340000 9970350000 9970360000 9991990000 Bus bar clamp 9970370000 Auxiliary contacts 9970300000 Lock out cover 9970380000 ETO 10/26, yellow (26 mm x 10 mm) 1686401687 Internal Auxiliary Wiring Diagram Auxiliary contacts SPDT Security hardware 14 12 11 Marking Tags Adhesive label 15 www.weidmuller.com Argentina Australia Austria Azerbaijan Bahrain Belarus Belgium BosniaHerzegovina Brazil Bulgaria Canada Chile China Colombia Costa Rica Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Germany Greece Hong Kong Hungary Iceland India Indonesia Iran Ireland Israel Italy Japan Jordan Kazakhstan Kuwait Latvia Lebanon Lithuania Luxembourg Macedonia Malaysia Malta Mexico Montenegro Netherlands New Zealand Norway Oman Paraguay Peru Philippines Poland Portugal Qatar Romania Russia Saudi Arabia Serbia Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (905) 475-2798 Email: info1@weidmuller.ca Website: www.weidmuller.ca 10/07 * 5M * LIT0706 Singapore Slovakia Slovenia South Africa South Korea Spain Sweden Switzerland Syria Taiwan Thailand Turkey UAE Ukraine United Kingdom Uruguay USA Venezuela Vietnam Yemen Weidmuller is the leading manufacturer of components for electrical connection technology to transmit energy, signals and data. The Weidmuller product portfolio ranges from terminal blocks, PCB connectors and terminals, protected components, Industrial Ethernet components, I/O components and relay sockets to power supplies and overvoltage protection modules suitable for all applications. Assemble Services, marking solutions with a variety of tools and software systems, round off the range. As an OEM supplier, the company sets global standards in the field of electrical connection technology. Weidmuller, Mexico Blvd. Hermanos Serdan 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: clientes@weidmuller.com.mx Website: www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: info@weidmuller.com Website: www.weidmuller.com