6
Digital Phase Shifter
6-Bit, 1.4 - 2.4 GHz
Rev. V4
MAPS-010163
• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.43537383 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
P/S LE Mode
1 X Serial
0 N/A Direct Parallel
Serial Mode
Direct Parallel Mode
The serial control interface (SERIN, CLK, LE,
SEROUT) is compatible with the SPI protocol. SPI
mode is activated when P/S is kept high. The 6-bit
serial word must be loaded with the MSB first. After
shifting in the 6 bit word, a rising edge on LE will set
the phase shifter to the desired state. While LE is
high the CLK is masked to protect the data while
implementing the change. SEROUT is SERIN
delayed by 6 clock cycles.
When P/S is low, the serial control interface is
disabled. When P/S is set high, Pins 22, 23, and 24
have the LE, CLK, and SER IN function.
In serial mode operation, the outputs will stay
constant while LE is kept low.
The parallel mode is enabled when P/S is set low. In
the direct parallel mode, the phase shifter is
controlled by the parallel control inputs directly.
When P/S is set low, Pins 22, 23, and 24 have the
D3, D2, and D1 function.
Modes of Operation:
Serial and Direct Parallel
Mode Truth Table
Serial Interface Timing Characteristics
Symbol Parameter
Typical Performance
Units
-40°C +25°C +85°C
tSCK Min. Serial Clock Period 100 100 100 ns
tCS Min. Control Set-up Time 20 20 20 ns
tCH Min. Control Hold Time 20 20 20 ns
tLS Min. LE Set-up Time 10 10 10 ns
tLEW Min. LE Pulse Width 10 10 10 ns
tLH Min. Serial Clock Hold Time from LE 10 10 10 ns
tLES Min. LE Pulse Spacing 630 630 630 ns
Truth Table (Digital Phase Shifter) 7
7. 0 = CMOS Low; 1 = CMOS High, X is CMOS Low or High
D5 D4 D3 D2 D1 Phase Shift
0 0 0 0 0 Reference Phase
0 0 0 0 1 5.6 deg
0 0 0 1 0 11.2 deg
0 0 1 0 0 22.5 deg
0 1 0 0 0 45 deg
1 0 0 0 0 90 deg
1 1 1 1 1 354.4 deg
D6
0
0
0
0
0
0
1
1 0 0 0 0 0 180 deg