LM301A, LM201A, LM201AV
http://onsemi.com
3
MAXIMUM RATINGS
Value
Rating Symbol LM201A LM201AV LM301A Unit
Power Supply Voltage VCC, VEE ±22 ±22 ±18 Vdc
Input Differential Voltage VID ±30 V
Input Common Mode Range (Note 1) VICR ±
V
Output Short Circuit Duration tSC
Power Dissipation (Package Limitation) PD
Plastic Dual−In−Line Package 625 625 625 mW
Derate above TA = +25°C 5.0 5.0 5.0 mW/°C
Operating Ambient Temperature Range TA−25 to +85 −40 to +105 0 to +70 °C
Storage Temperature Range Tstg
°C
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
ELECTRICAL CHARACTERISTICS (TA = +25°C, unless otherwise noted.) Unless otherwise specified, these specifications apply
for supply voltages from ±5.0 V to ±20 V for the LM201A and LM201AV, and from ±5.0 V to ±15 V for the LM301A.
Characteristic Symbol
LM201A / LM201AV LM301A
Unit
Min Typ Max Min Typ Max
Input Offset Voltage (RS ≤ 50 kW)VIO − 0.7 2.0 − 2.0 7.5 mV
Input Offset Current IIO − 1.5 10 − 3.0 50 nA
Input Bias Current IIB − 30 75 − 70 250 nA
Input Resistance ri1.5 4.0 − 0.5 2.0 − MW
Supply Current ICC,IEE mA
VCC/VEE = ±20 V − 1.8 3.0 − − −
VCC/VEE = ±15 V − − − − 1.8 3.0
Large Signal Voltage Gain AV50 160 − 25 160 − V/mV
(VCC/VEE = ±15 V, VO = ±10 V, RL > 2.0 kW)
The following specifications apply over the operating temperature range.
Input Offset Voltage (RS ≤ 50 kW)VIO − − 3.0 − − 10 mV
Input Offset Current IIO − − 20 − − 70 nA
Avg Temperature Coefficient of Input Offset
Voltage (Note 2) DVIO/DT− 3.0 15 − 6.0 30 mV/°C
TA(min) ≤ TA ≤ TA (max)
Avg Temperature Coefficient of Input Offset
Current (Note 2) DIIO/DTnA/°C
+25°C ≤ TA ≤ TA (max) − 0.01 0.1 − 0.01 0.3
TA(min) ≤ TA ≤ 25°C − 0.02 0.2 − 0.02 0.6
Input Bias Current IIB − − 100 − − 300 nA
Large Signal Voltage Gain AVOL 25 − − 15 − − V/mV
(VCC/VEE = ±15 V, VO = ±10V, RL > 2.0 kW)
Input Voltage Range VICR V
VCC/VEE = ±20 V −15 − +15 − − −
VCC/VEE = ±15 V − − − −12 − +12
Common Mode Rejection (RS ≤50 kW)CMR 80 96 − 70 90 − dB
Supply Voltage Rejection (RS ≤50 kW)PSR 80 96 − 70 96 − dB
Output Voltage Swing VO±12 ±14 − ±12 ±14 − V
(VCC/VEE = ±15 V, RL = ±10 kW, RL > 2.0 kW)±10 ±13 − ±10 ±13 −
Supply Currents (TA = TA(max), VCC/VEE = ±20 V) ICC,IEE − 1.2 2.5 − − − mA
1. For supply voltages less than ±15 V, the absolute maximum input voltage is equal to the supply voltage.
2. Guaranteed by design.