40 Industrial Way East, Eatontown , NJ 07724 [USA]
Phone: (732) 460-0212, Fax: (732) 460-0214
www.aeroflex.com/acc, email: acc-sales@aeroflex.com
Parameter Specification Units
Frequency Range (min) 2 – 18 GHz
Peak Input Power (max) 100 W
CW Input Power (max) 1 W
Peak Flat Leakage (max) 21 dBm
CW Flat Leakage (max) 18 dBm
Insertion Loss (max) 1.8 dB
VSWR (max) 1.9:1 ratio
Specifications:
Features:
• Built to protect sensitive circuit elements such as
receiver front ends or detectors.
• Reduce high power inputs to a low level that can be
tolerated by the next component.
• Handle up to 100W peak power levels and cover the
frequency range form 100MHz to 26GHz.
• Custom models with higher power handling are
available.
Revision Date: 2/23/2011
ACLM-4537
Pin Diode Limiter
Notes:
CW Leakage is measured at 1W input
Up to 1KW peak power handling is available.
Insertion loss and VSWR will degrade slightly.
Power handling is linearly derated from full power at
25˚C to zero power at +150˚C
Environmental Specifications:
Designed to meet:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Shock: MIL-STD-202F, M213, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Vibration: MIL-STD-202F, M204, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
SCREENING:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65°C to +100°C, 10 cycles
OPTIONAL HIGH-REL SCREENING
(Ref MIL-PRF-38534):
Stabilization Bake per MIL-STD-883, Method 1008
Temperature Cycle per MIL-STD-883, Method 1010
Constant Acceleration per MIL-STD-883, Method
2001
Burn-in per MIL-STD-883, Method 1015
Leak Test per MIL-STD-883, Method 1014
External Visual per MIL-STD-883, Method 2009