Product Descri ption
February 21, 2003
TMXL33625 Hypermap perLite
622/155 Mbits/s SONET/SDH x DS3/E3
1 Introduction
The docume ntation package for the TMXL33 625 Hyper ma pperLi te 622 /155 Mbits/s SONE T/ SDH x D S3/ E3 system chi p
consists of the following documents:
The Register Description. This document is available on a password protected website.
The HypermapperLite Product Description (this doc ume nt) , the System Design Guide, and the HypermapperLite Hard-
ware Design Guide. These documents are available on the public website shown below.
To contact Agere, please see the last page of this document. To access related documents, please contact your Agere rep-
resentative, or click on the following address: http://www.agere.com/enterprise_metro_access/mappers_muxes.html
Figure 1. Block Diagram and High-Level Interface Definition
(x12)
M13
MUX
FRM (X12)
x28/x21
DS1/J1/E1
(x12)
x28/x21
VTMPR
MRXC
A,B,C,D
DS1/J1/E1
VT/TU
DS3/E3
TPGM
(X4)
X12
x28/x21
DS1/E1
DJA
SPEMPR
(x12)
(0-2)
MCDR
A,B,C,D
MPU
JTAG
LOPOH
x4
x6
DS3/E3
DJA
(x12)
E13
MUX
CG
SPEMPR
x12
(3-5)
3
1
System Interfaces
(x24) DS3/E3
(x12) STS-1
(x12) NSMI
(x12) STS-1
(Total of 3 STS-1 Max/
group)
LOPOH
622/155 Mbits/s SONET/SDH
ADM Front End DS3/E3/D S 1 /E 1 P DH
Tribut ar y Termin ati on
TOAC
POAC
MPU IF
JTAG IF
PLL IF
24 24
DS3XCLK,
E3XCLK
DS1XCLK,
E1XCLK
Power and GND pins not shown
51
5
8
24
Mate Interconnect
48
(x12)
3
1
010903
Miscellaneous
CDR
CDR STSPP
A
Clock and Data
Clock/Sync TMUX-A
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
B
Clock and Data
Clock/Sync TMUX-B
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
C
Clock and Data
Clock/Sync TMUX-C
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
D
Clock and Data
Clock/Sync TMUX-D
S
T
S
X
C
6
8
8
W
P
STS1LT
(x12)
22
CS
A,B,C,D
From/To
TMUX A,B,C,D
54
168
96
D
C
B
A
ABCD
(x12)
M13
MUX
FRM (X12)
x28/x21
DS1/J1/E1
(x12)
x28/x21
VTMPR
MRXC
A,B,C,D
DS1/J1/E1
VT/TU
DS3/E3
TPGM
(X4)
X12
x28/x21
DS1/E1
DJA
SPEMPR
(x12)
(0-2)
MCDR
A,B,C,D
MPU
JTAG
LOPOH
x4
x6
DS3/E3
DJA
(x12)
E13
MUX
CG
SPEMPR
x12
(3-5)
3
1
System Interfaces
(x24) DS3/E3
(x12) STS-1
(x12) NSMI
(x12) STS-1
(Total of 3 STS-1 Max/
group)
LOPOH
622/155 Mbits/s SONET/SDH
ADM Front End DS3/E3/D S 1 /E 1 P DH
Tribut ar y Termin ati on
TOAC
POAC
MPU IF
JTAG IF
PLL IF
24 24
DS3XCLK,
E3XCLK
DS1XCLK,
E1XCLK
Power and GND pins not shown
51
5
8
24
Mate Interconnect
48
(x12)
4848
(x12)
3
1
010903
Miscellaneous
CDR
CDR STSPP
A
Clock and Data
Clock/Sync TMUX-A
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
A
Clock and Data
Clock/Sync TMUX-A
S
T
S
X
C
66
88
88
W
P
CDR
CDR STSPP
B
Clock and Data
Clock/Sync TMUX-B
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
B
Clock and Data
Clock/Sync TMUX-B
S
T
S
X
C
66
88
88
W
P
CDR
CDR STSPP
C
Clock and Data
Clock/Sync TMUX-C
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
C
Clock and Data
Clock/Sync TMUX-C
S
T
S
X
C
66
88
88
W
P
CDR
CDR STSPP
D
Clock and Data
Clock/Sync TMUX-D
S
T
S
X
C
6
8
8
W
P
CDR
CDR STSPP
D
Clock and Data
Clock/Sync TMUX-D
S
T
S
X
C
66
88
88
W
P
STS1LT
(x12)
22 22
CS
A,B,C,D
From/To
TMUX A,B,C,D
5454
168168
9696
D
C
B
A
ABCD
TMXL33625 HypermapperLite Product Description
622/155 Mbits/s SONET/SDH x DS3/E3 February 21, 2003
22 Agere Systems Inc.
Table of Contents
Contents Page
1 Introduction ........................................................................................................................................................................1
2 Features ............ ............. ............. ............. ............. ............. ............. ............ ............. ..........................................................4
2.1 TMUX and CDR Features (x4) ....................................................................................................................................4
2.2 CDR .............................................................................................................................................................................4
2.3 STS-12 Pointer Processor (STSPP) Features (x4) .....................................................................................................4
2.4 STS Cross Connect (STSXC) Features (x4) ...............................................................................................................5
2.5 Mate Clock and Data Recovery (MCDR) Features (x4) ..............................................................................................5
2.6 STS-1 Line Terminating (STS1LT) Features (x12) ......................................................................................................5
2.7 Synchronous Payload Envelope Mapper (SPEMPR) Features (x24) ..........................................................................5
2.8 Test Pattern Generator/Monitor (TPG/TPM) Features (x4) .........................................................................................6
2.9 Virtual Tributary Mapper (VTMPR) Features (x12) ......................................................................................................6
2.10 M13/E13 MUX Features (x12) ...................................................................................................................................6
2.10.1 M13 Featu re s ........... ...... ....... ...... ............................................. .......................................................................6
2.10.2 E13 Features ........................ ............................................. .............................................................................7
2.11 DS1/J1/E1 Framing Features (FRM) (12x28/21) (Performance Monitoring) .............................................................7
2.12 STS-1/DS3/E3/DS1/E1/VT/TU Multirate Cross Connect (MRXC) Features (x4) ......................................................8
2.13 DS1/E1 Digital Jitter Attenuation (DJA) Features (12x28/21) ....................................................................................8
2.14 DS3/E3 Digital Jitter Attenuation (DJA) Features (x4) ...............................................................................................8
2.15 Microprocessor Unit (MPU) Features (x1) .................................................................................................................9
2.16 JTAG .........................................................................................................................................................................9
3 Overview ............................................................................................................................................................................9
4 Applicati on Dia gr ams .................. ...... .............................................................................. .................................................10
4.1 Bidirectional STS-12 Portless TransMUX Application ...............................................................................................10
4.2 24 Clear Channel DS3/E3 to Dual STS-12/STM-4 Application .................................................................................11
4.3 DS3/E3 TransMUX Application .................................................................................................................................12
4.4 Single-Chip OC-12 with MSP 1 + 1 Protection Application .......................................................................................12
4.5 Single-Chip Dual OC-3 with MSP 1 + 1 Protection Application .................................................................................13
5 Block Description .............................................................................................................................................................14
5.1 TMUX/Clock and Data Recovery (CDR) Blocks ........................................................................................................14
5.1.1 Transmit Path Section/Line Overhead ............................................................................................................14
5.1.2 Receive Path Section/Line Overhead .............................................................................................................14
5.1.3 Pointer Interpreter ...........................................................................................................................................15
5.1.4 Path Termination Function ..............................................................................................................................15
5.2 STS-12/STM-4 Pointer Processor (STSPP) Block ....................................................................................................15
5.3 STS-1 Line Terminating (STS1LT) Block ..................................................................................................................15
5.4 STS Cross Connect (STSXC) Block ..........................................................................................................................15
5.5 Mate Interconnect and Clock Data Recovery (MCDR) Block ....................................................................................15
5.6 SPE/AU-3 Mapper (SPEMPR) Block .........................................................................................................................16
5.7 VT/TU Mapper (VTMPR) Block .................................................................................................................................16
5.7.1 Receive Direction ............................................................................................................................................16
5.7.2 Transmit Direction ...........................................................................................................................................16
5.8 M13/E13 Multiplexer (M13/E13 MUX) Blocks ...........................................................................................................17
5.8.1 M13 MUX ........................................................................................................................................................17
5.8.2 E13 MUX ........................................................................................................................................................18
5.9 Multirate Cross Connect (MRXC) Block ....................................................................................................................18
5.10 DS1 Digital Jitter Attenuator (DS1/E1 DJA) Block ...................................................................................................19
5.11 DS3 Digital Jitter Attenuator (DS3/E3 DJA) Block ...................................................................................................19
5.12 Test Pattern Generator/Monitor (TPG/TPM) Block ..................................................................................................19
5.13 Low-Order Path Over Head .....................................................................................................................................19
3Agere Systems Inc. 3
Table of Contents
Product Description TMXL33625 HypermapperLite
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
Contents Page
5.14 Framer Block ...........................................................................................................................................................20
5.14.1 Receive Frame Aligner/Transmit Frame Formatter ......................................................................................20
5.14.2 Receive Performance Monitor ......................................................................................................................20
5.14.3 Si gnalin g Proce ssor . ...... ....... ...... ....... ...... ....... ...... ........................................................................................20
5.14.4 Facility Data Link (FDL) Processor ...............................................................................................................21
5.14.5 HD LC Unit ... ...... ....... ...... ....... ...... ....... ...... ....... ...... ....... ...... ...... .....................................................................21
6 Glossary ..........................................................................................................................................................................22
Figure Page
Figure 1 . Blo ck Diagr a m and Hig h - L e ve l In te r face Defi n iti o n ......... ............. .............. .. ...... .............. ........................................... 1
Figure 2. Translates x12 Bidirectional M13/E13 Mapped STS-1s to/from x12 Bidirectional VT-1.5/TU-11/TU-12
Mapped STS-1s..................................................... ......... ......... .. ....... ......... ........... ......... ............................................ 10
Figure 3. 24 Clear Channel DS3/E3 to Dual STS-12/STM-4 Application.................................................................................. 11
Figure 4. x12 Channelized DS3s/E3s from/to x12 VT-Mapped STS-1s ................................................................................... 12
Figure 5. Single-Chip OC-12 with MSP 1 + 1 Protection Application........................................................................................ 12
Figure 6 . Sin g l e - Ch i p Du a l OC - 3 wit h MSP 1 + 1 Prot e ction Application...... ... ...... .............. ............. .............. ......................... 13
44 Agere Systems Inc.
Product Description
February 21, 2003
622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
2 Feat ures
Versatile IC supports SONET/SDH 622.08/
155.52 Mbits/s interface solutions for DS3/E3 applica-
tions.
Terminates up to 24 DS3/E3 channelized or
unchannelized signals with grooming for channelized
DS3/E3.
Terminated DS3/E3 and DS1/J1/E1 signals may be flexi-
bly mapped into the SONET/SDH interface using all
allowed MUXing structures.
Supports 1:1 and 1 + 1 protection schemes with dedi-
cated interfaces.
3.3 V I/O, 1.5 V CORE, and –40 °C to +85 °C tempera-
ture range allows for uncontrolled or convection cooled
environments. Maximum power estimated to be 6 W.
Built-in clock and data recovery circuits with optional
input for forward clocking of STS-3 input.
Full SONET/SDH compliant alarm reporting.
Supports full processing for all line/section/path over-
head with inhibitable automatic generation of AIS, RDI,
REI, and N times filtering on critical overhead.
Allows extraction/insertion of DCC-L, DCC-S, or up to
20 Mbits/s using specified overhead bytes for the data
communications channel.
Provides full high-speed pointer processing and synchro-
nization of the 8 kHz frame/2 kHz superframe to the sys-
tem timing.
Loopbacks, manual error insertion, internal pattern
generator/monitor, and internal cross connects simplify
debugging and diagnostics.
Standard 1152-pin ball grid array (PBGA).
Complies with all appropriate Telcordia®, ITU, ANSI ®,
ETSI, and Japanese TTC standards as noted.
2.1 TMUX and CDR Features (x4)
Multiplexes/demultiplexes twelve STS-1 signals or four
STS-3c signals to/from a SONET STS-12 signal.
Multiplexes three STS-1 signals into a SONET
STS-3 signal.
Multiplexes/demultiplexes four STM-1 (AU-4 or 3xAU-3)
signals to/from an SDH STM-4 signal.
Multiplexes/demultiplexes three VC-3 signals to/from an
SDH STM-1 (3xA U-3) signal.
Multiplexes/demultiplexes three VC-3 signals to/from an
SDH STM-1 (AU-4) signal via a TUG-3 construction.
Provides STS-1-only mode for receive and transmit
directions.
Provides separate protection input for support of 1:1
and 1 + 1.
Provides SONET/SDH loss-of-signal (LOS), out-of-frame
(OOF), loss-of-frame (LOF), and loss-of-clock (LOC)
detection.
Provides STS-12/STM-4/STS-3/STM-1/STS-1 selectable
scrambler/descrambler functions.
Provides B1/B2/B3 generation/detection for STS-12/
STM-4/STS-3/STM-1/STS-1.
Provides STS-12/STM-4/STS-3/STM-1/STS-1 pointer
interpretation.
Complies with GR-253-CORE, T1.105, G.707, G.783,
G.806, G.821, and ETSI 417-1-1.
2.2 CDR
Receives data at STS-12/STM-4 (622.08 Mbits/s) or
STS-3/ST M -1 (155.52 MHz ) data rate.
155.52 MHz/622.08 MHz ± 20 ppm input reference clock
for on-chip PLL.
On-chip PLL for clock synthesis, that requires only one
external resistor, generates 16 phases, and provides res-
olution of approximately 200 ps.
PLL bypass mode for functional test.
Meets type B jitter tolerance specification of ITU-T
recommendation G.783.
No output clock drift in absence of data transitions once
lock is acquired.
2.3 STS-12 Pointer Processor (STSPP)
Feature s (x4)
SONET and SDH compliant.
Configurable STS-3/STM-1 or STS-12/STM-4 mode.
Supports an arbitrary mix of STS-1 and STS-3c
tributaries, and SDH equivalents for passthrough from
receiver to transmitter.
Supports STS-n add/drop capability.
Complies with GR-253-CORE, T1.105, G.707, G.783,
G.806, G.821, and ETSI 417-1-1.
Agere Systems Inc. 5
Product Description
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
2 Feat ures (continued)
2.4 STS Cross Connect (STSXC) Features (x4)
Internal clocks and controls are user transparent.
30 x 30 STS-1 strictly nonblocking cross connect.
The following STSXC outputs may be sourced from the
subsequent list of inputs without restriction per
STS-1/STM-0. (Must be between blocks of the same par-
tition, i.e., A, B, C, or D.)
2.5 Mate Clock and Data Recovery (MCDR)
Features (x4)
Provides glueless capability to connect partitions (A, B,
C, D) of the HypermapperLite device.
Loss-of-clock detection from the three external
155.52 MHz clock inputs.
Loss- of -frame (LOF ), out-of-frame (OOF), and B2 error
detection on the three 155.52 Mbits/s interfaces. Also
RDI and REI monitoring and generation is available.
Manual B2 error insertion for debugging.
2.6 STS-1 Line Terminating (STS1LT)
Features (x12)
Supports standard SPE mappings for sub-STS-1 pay-
loads (VT-mapped: 28 DS1, 28 J1, or 21 E1 signals).
Supports standard SPE mappings for STS-1 payloads
(DS3/E3).
Detects STS-1 loss-of-signal (LOS), out-of-frame (OOF),
loss-of-frame (LOF), AIS-P, and LOP conditions.
Provides STS-1 selectable scrambler/descrambler func-
tions and B1/B2/B3 generation/detection.
Provides STS-1 pointer interpretation/processing.
Complies with GR-253-CORE, T1.105, G.707, G.783,
G.826, G.821, and ETSI 417-1-1.
2.7 Synchrono us Paylo ad Enve lo pe Map per
(SPEMPR) Features (x24)
The SPE mapper accepts/delivers TUG-2 data from/to
the VT mapper. The TUG-2 data is mapped/demapped
either to/from an AU-3/STS-1 signal for the North Ameri-
can digital systems or to/from a TUG-3 signal for the ITU-
based systems. Only available for SPEMPR 0—2.
The SPE mapper accepts/delivers channelized DS3 data
from/to the M13 MUX/deMUX. The DS3 data is mapped/
demapped either to/from an AU-3/STS-1 signal for the
North American digital systems or to/from a TUG-3 signal
for the ITU-based systems. Only available for SPEMPR
3—5.
The SPE mapper accepts/delivers channelized or
unchannelized DS3 signals at a 44.736 Mbits/s rate from
external I/O. The DS3 signals are mapped/demapped
the same way as the M13 signal described above.
The SPE mapper accepts/delivers channelized E3 data
from/to the E13 MUX/deMUX. The E3 data is mapped/
demapped either to/from an AU-3/STS-1 signal for the
North American digital systems or to/from a TUG-3 signal
for the ITU-based systems. Only available for SPEMPR
3—5.
The SPE mapper accepts/delivers channelized or
unchannelized E3 signals at a 34.368 Mbits/s rate from
external I/O. These E3 signals are mapped/demapped
the same way as the E13 signal described above.
The SPE mapper has a DS3/E3 loopback circuit placed
to demap and remap a DS3/E3 signal. It is particularly
useful in cases where a DS3/E3 signal, mapped as an
AU-3/STS-1 signal, requires remapping as a TUG-3 sig-
nal or vice versa.
The SPE mapper supports a path overhead access
channel (POAC). Seven path overhead bytes (J1, C2,
F2, H4, F3, K3, and N1) can be inserted/dropped through
this channel. This channel works as the master , meaning
it provides a clock in both the transmit and receive direc-
tions and POH data can be inserted on the transmit side
or dropped on the receive side.
Path overhead byte B3 (BIP error) generation/detection
and programmable BIP-8 bit error rate insertion.
Signal fail and signal degrade indicators available to
report bit error rates above standard provisionable
thresholds.
Number of STS-1s Output Block
12 TMUX
6SPEMPR
3 STS1LT or STS1LT PP
9 Mate CDR (from TMUX only)
Number of STS-1s Input Block
12 TMUX or STS-12PP
6SPEMPR
3STS1LT
9 Mate CDR (to TMUX only)
66 Agere Systems Inc.
Product Description
February 21, 2003
622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
2 Feat ures (continued)
Capable of detecting/inserting AIS, RDI, and REI.
Monitori ng is prov id ed on all the TU G-3 path overhea d
bytes.
N1 tandem connection support is provided.
TUG-3 pointer processor supports add/drop multiplexing.
Complies with GR-253-CORE, T1.105, ITU-T G.707,
ITU-T G.831, G.7 83, and ETS 300 417- 1-1.
2.8 Test Pattern Generator/Monitor (TPG/TPM)
Features (x4)
Configurable test pattern generator: DS1, E1 and DS3,
E3, or STS-1 formats.
Provisionable test pattern data from the following
options: quasirandom signal source (QRSS), pseudoran-
dom bit stream length of 215 –1 (PRB S15 ), PRBS 20,
PRBS23, alternating 1 and 0 (AL T_01), ALL_ONES, user
pattern (16 bits, repeating).
The DS1 and E1 test patterns can be transmitted either
unframed or as the payload of a framed signal as defined
in ITU-T (DS3, E3, or STS-1 unframed only).
Under register control, single bit or framing (DS1/E1
only) errors can be injected into any test pattern.
Any sink or receiving channel can be replaced by a test
pattern monitor, which can detect and count bit errors or
misconfigurations, and/or detect idle conditions or AIS.
Datalink (DS1-ESF DL) and SSM (E1 multiframe Sa)
fields read/writable.
Supports all HypermapperLite modes of operation.
Complies with T1.107, T1.231, T1.403, G.703, G.704,
and O.150.
2.9 Virtual Tributary Mapper (VTMPR)
Features (x12)
Maps DS1/J1/E1 into VT/TU structures:
DS1 into VT1.5/TU-11/TU-12.
J1 into VT1.5/TU-11/TU-12.
E1 into VT2/TU-12.
Maps VC-11/VC-12 into VTG/TUG-2 structures:
VC-11 into VT1.5/TU-11/TU-12/VTG/TUG-2.
VC-12 into VT2/TU-12/VTG/TUG-2.
Synchronizes VT/TU SPE to system-shelf-timing
reference by setting the transmit VT/TU pointers to fixed
values for asynchronous mapping or by dynamically
changing the transmit VT/TU pointers for byte
synchronous mapping.
Supports asynchronous, byte synchronous, and bit
synchronous mappings.
Supports automatic generation or microprocessor
overwrite of one bit RDI-V or enhanced RDI-V, and one
bit RFI-V.
Supports ADM applications with tributary loopback and
tributary pointer processing.
Provides a low-order path overhead access channel.
Supports TIM-V generation and termination for all 28/21
VT/TU signals.
Supports BIP-V BER insertion and detection.
Supports fast AIS generation for downstream devices.
Supports a one second error counter for BIP-V and
REI-V.
Allows grooming of VTs/TUs in granularity of TUG-2s
within the STS-3/STM-1 signal.
Configurable VT/TU slot selection for DS1, E1, and J1
insertion and drop.
Automatic receive monitor functions include VT/TU
RDI-V, REI-V, BIP-2 errors, AIS-V, and LOP-V.
Supports all HypermapperLite modes of operation.
Complies with O.150, T1.105, T1.107, T1.231, T1.403,
G.703, G.704, G.707, G.783, GR-253-CORE, GR-499,
JT-G707, and ETS 300 417-1-1.
2.10 M13/E13 MUX Features (x12)
2.10.1 M13 Features
Configurable multiplexer/demultiplexer for 28 DS1 sig-
nals or 21 E1 signals to/from a DS3 signal.
Operates in either M23 or C-bit parity mode.
Provisionable time-slot selection for DS1 and E1
insertion or drop.
Full alarm monitoring and generation (LOS, BPV, EXZ,
OOF, SEF, AIS, RAI, FEAC, P-bit and C-bit parity errors,
and FEBE).
Agere Systems Inc. 7
Product Description TMXL33625 HypermapperLite
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
2 Feat ures (continued)
DS3 forced loopback and DS1 and E1 forced loopback
and loopback request generation.
Complies with T1.102, T1.107, T1.231, T1.403, T1.404,
GR 499, G.747, and G.775.
2.10.2 E13 Features
Configurable multiplexer/demultiplexer for up to 16 E1
signals to/from an E3 signal.
Provisionable time-slot selection for E1 insertion or drop
via the multirate cross connect functional block.
E13 multiplexers capable of generating alarm indication
signal (AIS) and remote alarm indicator (RAI) signals.
Configurable HDB3 encoder/decoder for E3 output/input.
E1 transmit path monitors that detect loss-of-clock (LOC)
and AIS.
E3 receive monitor that detects loss-of-signal (LOS),
LOC, bipolar violation (BPV), AIS, and RAI.
E3 and E2 loopback modes.
Complies with ITU G.703, G.742, G.751, and G.775.
2.11 DS1/J1/E1 Framing Features (FRM)
(12x28/21) (Performance Monitoring)
28/21 DS1/J1/E1 channels.
DS1 framing modes: ESF, D4, SLC ®-96, T1 DM DDS,
and SF (Ft only).
E1 framing modes: G.704 basic and CRC-4 multiframe
consistent with G.706.
J1 framing modes: JESF (Japan).
DS1 signaling modes: transparent; register and system
access for ESF 2-state, 4-state, and 16-state; D4 2-state,
4-state, and 16-state; SLC-96 2-state, 4-state, and
16-state; J-ESF handling groups maintenance and
signaling; VT 1.5 SPE 2-state, 4-state, 16-state.
E1 signaling modes: transparent; register and system
access for entire TS16 multiframe structure as per ITU
G.732.
Signaling debounce and change of state interrupt.
V5 .2 Sa7 processing.
Alarm reporting and performance monitoring per AT&T ®,
ANSI, ITU-T, and ETSI standards.
Facility data link features:
HDLC or transparent access for either ESF or
DDS + FDL frame formats.
Register/stack access for SLC-96 transmit and receive
data.
Extended superframe (ESF): automatic transmission
of the ESF performance report messages (PRM).
Automatic transmission of the ANSI T1.403 ESF per-
formance report messages. Automatic detection and
transmission of the ANSI T1.403 ESF FDL bit-oriented
codes.
Register/stack access for all CEPT Sa bits transmit
and receive data.
HDLC features:
HDLC or transparent mode.
Programmable logical channel assignment: any time-
slot, any bit for ISDN D channel, also inserts/extracts
C-channels for V5.1, V5.2 interfaces.
64 logical channels in both transmit and receive direc-
tion (any framing format).
Maximum channel data rate is 64 kbits/s.
Minimum channel data rate is 4 kbits/s (DS1/FDL or
E1 Sa bit).
128-byte FIFO per channel in both transmit and
receive directions.
Tx to Rx loopback supported.
TMXL33625 HypermapperLite Product Description
622/155 Mbits/s SONET/SDH x DS3/E3 February 21, 2003
88 Agere Systems Inc.
2 Feat ures (continued)
2.12 STS-1/DS3/E3/DS1/E1/VT/TU Multirate
Cross Connect (MRXC) Features (x4)
Configurable cross point interconnect for up to 84/63
DS1/E1 signals to/from the FRM, VTMPR, M13/E13,
TPG/TPM, and DS1/E1 DJA.
Connects three DS3/E3 signals from the external pins to
the M13/E13 MUX. Connects six DS3/E3 signals
between the external pins and DS3/E3 DJA, SPEMPR,
and three STS-1 signals from external pins to the
STS1LT.
Also connects three external NSMI interfaces to the
SPEMPR or M13/E13.
Three NSMI ports are shared with three STS-1 line termi-
nations.
Provides grooming capability for up to 168 (84 receive
plus 84 transmit) DS1/E1 connections between the FRM,
VTMPR, M13/E13, and DS1/E1 DJA. This allows for
cross connect grooming of any block signal port n to any
other signa l por t m on a different block, or on the same
block in the case of a groomed loopback.
Multicast operation (one to many) is supported for 168
sources and destinations.
Multirate cross connect allows 16 x 3 E1 signals to/from
E13 modules from/to the framer, VT mapper, and
TPG/TPM.
There are three E3 signals from/to the E13 functional
block to/from external pins and the SPE mapper.
Jitter attenuation can also be inserted in-line on any
DS3/E3 or DS1/E1 channel. (Note that cascading of jitter
attenuators is not allowed.)
Standard network loopback or straight-away facility
testing is supported for DS1/E1 and DS3/E3. A test-
pattern generator capable of injecting idle standards-
based, pseudorandom bit sequence test patterns, or AIS
(blue) alarm can replace any source or transmitter. A
test-pattern monitor that can detect/count bit errors in a
pseudorandom test sequence, or loss of frame or
synchronization, can replace any sink or receiver.
One to any number of loopbacks are supported for up to
84/63 channels in DS1/E1 channels from the VT mapper ,
M13/E13, and framer functional blocks. One-to-one
loopback is supported in all DS1/E1 channels. One-to-
one loopback is supported for DS3/E3 channels from the
M13/E13, and SPE mapper functional blocks.
Loopbacks can be configured to sectionalize a circuit for
identifying faults or misconfiguration during out of service
maintenance.
Fast alarm channels are supported for VT mapper, E13,
and M13 to framer interconnects for alarm indication
signal (AIS or blue alarm) and VT mapper only for remote
alarm indicator (RAI or yellow alarm). This feature
reduces the propagation delay of the alarms by
eliminating multiple integration of alarm conditions.
2.13 DS1/E1 Digital Jitter Attenuation (DJA)
Features (12x28/21)
The PLL bandwidth, damping factor, and sampling rates
are programmable.
Configurable to meet jitter and MTIE requirements.
Supports one DJA per each DS1/E1. (Note that the DJA
may not be cascaded.) 28/21 DJAs per block.
2.14 DS3/E3 Digital Jitter Attenuation (DJA)
Features (x4)
The PLL bandwidth, damping factor, and sampling rates
are programmable.
The DJA functional block accepts/delivers DS3/E3 clock
and data from/to the multirate cross connect functional
block.
Supports one DJA per each DS3/E3. (Note that the DJA
may not be cascaded.) Six DJAs per block.
Agere Systems Inc. 9
Product Description
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
2 Feat ures (continued)
2.15 Microproc essor Unit (MPU) Features (x1)
21-bit address/16-bit data bus microprocessor interface
(little end ian ).
Synchronous (16 MHz to 66 MHz)/asynchronous
microprocessor interface modes.
Microprocessor data bus parity monitoring.
Summary of two level priority interrupts from major
functional blocks (maskable).
Separate device interrupt outputs for automatic
protection switch and the HypermapperLite global
interrupts.
Global configuration of network performance monitoring
counters operation.
Global software resets.
Global enabling and powerdown of major functional
blocks.
Registers provisionable for clear on read/clear on write.
Compatible with most industry-standard processors.
2.16 JTAG
IEEE ® 1149.1 JTAG boundary scan.
3 Overvi ew
The SONET/ SDH Hyp ermap per Li te devic e inte grates the
SONET/SDH section, line, path, and tributary termination
functions with M13/E13 multiplex functions and the primary
rate framing function. It interfaces to multiple OC-3/STM-1
optical signals or to an OC-12/STM-4 for terminal or add/
drop applications.
The SONET/ SDH Hyp er map perLi te dev ice pro vides a ver-
satile interface for STS-12/STM-4, STS-3/STM-1, and
STS-1/STM-0 termination applications for point-to-point
scenarios and ring applications.
Mapping flexibility allows for software upgrades from M13/
E13 mapped connections to VT/TU mapped connections.
A single HypermapperLite is capable of processing the
aggregate bandwidth of one STS-12/STM-4 to 12
transMUXed DS3/E3s. Further, a single device can
process the aggregate bandwidth of two STS-12/STSM-4s
terminated to 24 clear-channel DS3/E3s. Additionally, a
single HypermapperLite can function as an STS-12/STS-3/
STM-4/STM-1 add/drop MUX by terminating up to 12
STS-1/STM-0 channels or four AU-4 channels and by
using the internal pointer processors to forward any
nonterminating channels. The device is ideal for other
applications including dual STS-12/STM-4 portless
transMUX, dual STS-3/STM-1 with MSP 1 + 1 protection,
and single-chip STS-12/STM-4 MSP 1 + 1 applications,
among others .
TMXL33625 HypermapperLite Product Description
622/155 Mbits/s SONET/SDH x DS3/E3 February 21, 2003
1010 Agere Systems Inc.
4 Application Diagrams
This section shows several typical HypermapperLite applications. Figure 2 through Figure 6 d epict sy s tem- lev el dia gr ams .
4.1 Bidirectional STS-12 Portless TransMUX App lication
Each of two STS-12s consist of x6 VT/TU-mapped STS-1s, and x6 M13/E13-mapped STS-1s.
HypermapperLite will bidirectionally transMUX between DS1-mapped DS3s and VT-mapped STS-1s.
STS-12 interface to backplane is 622 Mbits/s LVDS with integrated CDR.
Eight local glueless board-level signal connections required as shown in Figure 2.
Provides PMON and FDL to all 336/252 bidirectional DS1s/E1s.
Provides DS3 PMON and FEAC for all 12 bidirectional DS3s.
Provides high-order section/line/path overhead termination and insertion for 24 STS-1s.
Figure 2. Translates x12 Bidirectional M13/E13 Mapped STS-1s to/from
x12 Bidirectional VT-1.5/TU-11/TU-12 Mapped STS-1s
HYPERMAPPERLITE
CROSS CONNECT
x6 VT-1.5/TU-11/TU -12
MAPPED ST S-1
STS-12 INTERFACE
x3 STS-1
BACKPLANE
WITH STS- 1
x6 M13/E13
MAPPED STS- 1
STS-12/STM-4
3
x6 VT-1.5/TU-11/TU -12
MAPPED ST S-1
x6 M13/E13
MAPPED STS- 1
STS-12/STM-4
INTERFACE
STS-3 INTERFACE
STS-12 INTERFACE
STS-3 INTERFACE x3 STS-1
3
CLK GEN
TSWC01622
REF CLK
Agere Systems Inc. 11
Product Description TMXL33625 HypermapperLite
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
4 Application Diagrams (continued)
4.2 24 Clear Channel DS3/E3 to Dual STS-12/STM-4 App lication
Two STS-12/STM-4 signals will be input to the high-speed interfaces of the device and deMUXed to 24 DS3s/E3s.
Similarly, 24 DS3s/E3s are input from LIUs and MUXed to two STS-12s/STM-4s.
STS-12 interface to backplane is 622 Mbits/s LVDS with integrated CDR.
Eight local glueless board-level signal connections required.
Provides DS3 PMON and FEAC for all 24 bidirectional DS3s.
Provides high-order section/line/path overhead termination and insertion for 24 STS-1s.
Figure 3. 24 Clear Channel DS3/E3 to Dual STS-12/STM-4 Application
HYPERMAPPERLITE
STS-12 INTER FACE
OC-12/STM-4o STS-12/STM-4e
STS-12 INTER FACE
DS3/E3
24
OC-12/STM-4o STS-12/STM-4e DS3/E3 LIU
CLK GEN
TSWC01622
REF CLK
OC-12
TRANSCEIVER
OC-12
TRANSCEIVER
TMXL33625 HypermapperLite Product Description
622/155 Mbits/s SONET/SDH x DS3/E3 February 21, 2003
1212 Agere Systems Inc.
4 Application Diagrams (continued)
4.3 DS3/E3 TransMUX Application
12 DS3s/E3s are input from LIUs and MUXed to an STS-12/STM-4 level.
Similarly, an STS-12/STM-4 is input to the high-speed interface of the master device and deMUXed to 12 DS3s/E3s.
HypermapperLite will bidirectionally transMUX between DS1-mapped DS3s and VT-mapped STS-1s.
STS-12 interface to backplane is 622 Mbits/s LVDS with integrated CDR.
Six local glueless board-level signal connections required.
Optional connection to internal framer blocks to provide PMON for all 336/252/144 bidirectional DS1s/E1s.
Provides high-order section/line/path overhead termination and insertion for 24 STS-1s.
Figure 4. x12 Channelized DS3s/E3s from/to x12 VT-Mapped STS-1s
4.4 Single-Chip OC-12 with MSP 1 + 1 Protection Application
An STS-12/STM-4 signal is input to the high-speed interface of the device and deMUXed to DS3s/E3s and/or
STS-1/EC-1 level.
Similarly, multiple STS-1s/EC-1s and/or DS3s/E3s can be input to the device and MUXed to an
STS-12/STM-4 signal.
One TMUX subblock (A, B, C, or D) provides the interface to the working line while another provides the interface to the
protection line. MSP 1 + 1 achieved via external connection between these two TMUX subblocks.
STS-12 (working and protect) interfaces to backplane are 622 Mbits/s LVDS with integrated CDR.
Eight local glueless board-level signal connections required.
Number of possible DS3s/E3s and STS-1s/EC-1s dependent on application (mapping type and signal path through the
device).
Figure 5. Single-Chip OC-12 with MSP 1 + 1 Protection Application
HYPERMAPPERLITE
STS-12 INTERF ACE
OC-12/STM-4o STS-12/STM-4e DS3/E3
12 DS3/E3 LIU
CLK GEN
TSWC01622
REF CLK
OC-12
TRANSCEIVER
HYPERMAPPERLITE
STS-12 INTERFACE
OC-12/STM-4o STS-12/STM-4e
WORKING
STS-12 INTERFACE
STS-1/EC-1
OC-12/STM-4o STS-12/STM-4e
PROTECTION
DS3/E3
CLK GEN
TSWC01622
REF CLK
OC-12
TRANSCEIVER
OC-12
TRANSCEIVER
Agere Systems Inc. 13
Product Description TMXL33625 HypermapperLite
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
4 Application Diagrams (continued)
4.5 Single-Chip Dual OC-3 with MSP 1 + 1 Protection Application
Two STS-3/STM-1 signals are input to the high-speed interfaces of the device. Both signals are replicated and sent into
the two other dedicated high-speed interfaces as protection lines.
The dual STS-3s/STM-1s can be deMUXed to STS-1s/STM-0s and/or DS3s/E3s. Termination dependent on application
desired.
Similarly, a mix of STS-1s/STM-0s and/or DS3s/E3s can be MUXed to STS-3/STM-1 level (to two separate STS-3s/STM-
1s).
Two internal TMUX blocks provide the interface to the receive/transmit protection links.
The device is effectively split in half: one half is dedicated to working/protecting STS-3/STM-1 #1, while the other is
dedicated to STS-3/STM-1 #2.
Figure 6. Single-Chip Dual OC-3 with MSP 1 + 1 Protection Application
HYPERMAPPERLITE
STS-3 INTERFACE
OC-3/STM-1o STS-3/STM-1e
WORKING 1
STS-3 INTERFACE
STS-1/STM-0
OC-3/STM-1o STS-3/STM-1e
PROTECTION 1
DS3/E3
STS-3 INTERFACE
OC-3/STM-1o STS-3/STM-1e
WORKING 2
STS-3 INTERFACE
STS-1/STM-0
OC-3/STM-1o STS-3/STM-1e
PROTECTION 2
DS3/E3
CLK GEN
TSWC01622
REF CLK
OC-3
TRANSCEIVER
OC-3
TRANSCEIVER
OC-3
TRANSCEIVER
OC-3
TRANSCEIVER
1414 Agere Systems Inc.
Product Description
February 21, 2003
622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
5 Block Description
5.1 TMUX/Clock and Data Recovery (CDR)
Blocks
The TMUX and CDR blocks (four per device) provide the
high-speed interfaces to the SONET/SDH line and
terminate the section and line signals. Several features are
incorporated in these blocks to allow for a variety of system
applications. First, a redundant interface is provided with
the appropriate selectors and bridges to allow easy
implementation of 1:1, 1 + 1, or ring protection schemes.
Second, a separate interface is provided for access to
selected overhead bytes. In SONET applications, the
section DCC-S may be added/dropped at 192 kbits/s, while
SDH applications may use the same I/O for adding/
dropping the DCC-L at 576 kbits/s. Alternately, any bytes in
the entire overhead may be added/dropped. A third feature
of these blocks is that they can operate at both
622.08 Mbits/s or 155.52 Mbits/s, where the 155.52 Mbits/s
mode may use a clock forwarded from the external PHY
device. In this mode, both the receive and transmit
directions of the device may operate asynchronously. In the
622 Mbits/s mode, a CDR is provided for ease of retiming
the data signal. The fourth and final function of these blocks
is to terminate/generate the section, line, and path
overhead (only for the SONET/SDH STS-12/3 or STM-4/1
signals). Automatic generation of AIS/RDI/REI is possible
since the protection path is available on the device.
Additionally, N times filtering is provided for critical bytes
such as K1/K2. All variations in overhead processing
between SONET and SDH are also accommodated. A
summary of the overhead processing follows and includes
the pointer interpretation function necessary for AIS
detection.
5.1.1 Transmit Path Section/Line Overhead
Transmit path section/line overhead is as follows:
Synchronizing status byte (S1) insertion
M0/M1 REI-L insertion; automatic insertion may be
inhibited
K1 and K2 insertion, AIS-L insertion
B2 calculation and insertion
F1 byte insertion
B1 generation and error insertion
Scrambler
J0 insert control
A2 erro r in s er t i on
The entire APS value or K2[2:0] can be inserted via
microprocessor control. Automatic RDI insertion is
supported with individual inhibits for each contributor. A
protection switch selects the RDI-L value for insertion from
the protection board rather than from the working side.
B1 and B2 BIP-8 values are calculated and inserted. Both
values can be inverted.
5.1.2 Receive Path Section/Line Overhead
Receive path section/line overhead is as follows:
Frame alignment (STS-12/STM-4 or STS-3)
B1 BIP-8 check
J0 monitoring
Descrambling
F1 monitoring
B2 BIP-8 check
APS and K2 monito ri ng
AIS-L and RDI-L detection
M1 REI-L detection
S1 synchronization status monitoring
Framer states and all other state changes are reported.
These cause an interrupt if not masked.
The B1 and B2 parity check supp orts both bit and bloc k
modes. The counters count up to one second’s worth of
BIP errors. These stay at their maximum value in case of
overflow or rollover and should be read (and cleared) at
least once per second.
The J0 monitor supports nonframed, SONET-framed, and
SDH-framed 16-byte sequences, as well as single J0 byte
monitoring modes.
APS monito ring is perform ed on K1[7 :0] and K2[ 7:3] . The
value is stored, and changes are reported. Bits [2:0] of the
K2 byte are monitored independently.
The alarm indication signal (AIS -L /MS -AIS ) and remote
defect indication (RDI-L/MS-RDI) are monitored separately ,
and changes are reported. This information is also sent to
the protection device for ADM applications.
The M1 monitor operates either in bit or block mode and
allows access to the remote error indication
(REI-L/MS-REI) errored bit count.
The S1 by te c an be m oni tored eith er as an entir e 8- bit w ord
or as one 4-bit nibble (bits 7:4).
Agere Systems Inc. 15
Product Description
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
5 Block Description (continued)
5.1.3 Pointer Interpreter
The TMUX pointer interpreter conforms to ETS 300
417-1-1: January 1996—Annex B.
The pointer interpreter evaluates the current pointer state
for the normal state, path AIS state, or LOP (loss of pointer)
conditions, as well as pointer increments and decrements.
The current pointer state and any changes in pointer
condition are reported to the control system. The number of
consecutive frames for invalid pointer and invalid
concatenation indication is fixed at nine.
5.1.4 Path Termination Function
In STS-3/STM-1 mode, path termination is performed on
either all three STS-1s or on the VC-4. In the
STS-12/STM-4 mode, path termination is performed either
on all twelve STS-1s/four STS-3cs, or on the four VC-4
POH. On the receive side, it includes the following:
J1 monitoring
B3 BIP-8 check ing
C2 signal label monitoring
REI-P and RDI-P detection
H4 multiframe monitoring
F2, F3, and K3 automatic protection switch monitoring
N1 tandem connection monitoring
Signal degrade BER and signal fail BER detection
Path overhead access channel (RPOAC) drop
AIS-P/HO-AIS insertion
Automatic AIS generation (with individual inhibit)
The J1 monitor (as found in the TMUX block) provides the
following four modes of operation (16 byte or 64 byte):
SONET mode
SDH mode
User mode
Single byte mode
Note: For additional J1 functionality, please refer to the
STS1-LT and SPEMPR sections of the Register
Description document.
B3 is monitored either in bit or block mode. Provisionable
N-times detection counters are implemented for C2, F2,
F3, N1, and K3 bytes. The K3 APS byte and N1 TCM byte
can be monitored as an entire 8-bit word or as two 4-bit nib-
bles.
5.2 STS-12/STM-4 Pointer Processor (STSPP)
Block
A pointer processor (four per device) is used to move a
SONET/SDH payload from the line clock domain to the
system clock domain. The HypermapperLite STS-12
pointer processors are SONET and SDH compliant and
offer a configurable STS-3/STM-1 or STS-12/STM-4 mode.
They support an arbitrary mix of STS-1/STS-3c tributaries
and SDH equivalents, and comply with GR-253-CORE,
T1.105, G.707, G.783, G.826, G.821, and ETSI 417-1-1.
5.3 STS-1 Line Terminating (STS1LT) Block
The STS-1 line terminating block (12 per device) allows
termination of an STS-1 line signal routed from the
multirate cross connect. It provides access to the section/
line and path overhead similarly to the TMUX. It can also
source an SPE to the STS cross connect for transport on
the high-speed line interface.
5.4 STS Cross Connect (STSXC) Block
The high-order cross connect block (four per device)
connects the SONET/SDH interfaces to the PDH portion of
the device. It will permit connections that support a variety
of applications. The data paths, clocks, and syncs are
internally configured as appropriate for the different signal
rates and interconnects. A significant portion of the STSXC
block is the mate interconnect described in Section 5.5.
5.5 Mate Interconnect and Clock Data Recovery
(MCDR) Block
The HypermapperLite can be configured to terminate an
STS-12/STM-4 signal by connecting the device partitions
(A, B, C, D) together via the mate interconnect. Each
interconnect operates at 155 Mbits/s and is connected
between a single HypermapperLite partition configured as
master and up to three HypermapperLite partitions with
high-speed TMUX input configured as slaves. The mate
interconnect uses SONET/SDH framing and overhead so
there is performance monit oring of the link between
partitions.
Note: Not all applications require all four partitions to fully
terminate an STS-12/STM-4.
TMXL33625 HypermapperLite Product Description
622/155 Mbits/s SONET/SDH x DS3/E3 February 21, 2003
1616 Agere Systems Inc.
5 Block Description (continued)
5.6 SPE/AU-3 Mapper (SPEMPR) Block
The SPE mapper functional block (24 per device) operates
either as an AU-3/STS-1 mapper or as a TUG-3 mapper . In
either mode, it maps/demaps data from/to either the VT
mapper, the M13/E13 MUX/deMUX, the DS3/E3 clear
channel, or the DS3/E3 loopback channel. The SPE
mapper supports numerous automatic monitoring functions
and provides interrupts to the control system, or it can be
operated in a polled mode.
In DS3 mapping mode, the SPE mapper functional block
accepts/delivers structured DS3 data from/to the M13
functional block or a clear channel DS3 signal at
44.736 Mbits/s rate and maps/demaps it asynchronously
to/from the STS-1 SPE or a TU-3. The DS3 mapper
generates a fixed pointer value of 522.
On the receive side, pointer interpretation is performed,
detecting LOP, AIS, NDF, NORM, INC, and DEC. A DS3
loopback mode allows demapping and remapping of a DS3
signal. It is particularly useful in cases where a DS3 signal
mapped as AU-3/STS-1 needs to be remapped as a TU-3
signal or vice versa. B3ZS encoding/decoding is included.
The E3 mapping mode is similar in functionality to that of
the DS3 mapping mode just described.
This functional block also connects to the path overhead
access channel (POAC) to insert/drop path overhead bytes
J1, C2, F2, H4, F3, K3, and N1 into/from the STS-1 SPE or
VC-3.
The SPE mapper functional block complies with GR-253-
CORE, T1.105, ITU-T G.707, ITU-T G.831, G.783, and ETS
300 417-1-1.
5.7 VT/TU Mapper (VTMPR) Block
The VT/TU mapper (12 per device) maps any valid combi-
nation of DS1 and E1 signals into a stream at a rate of
51.84 Mbits/s (STS-1 or AU-3). The mapping methods
(VT1.5, VT2, and VT group in ANSI nomenclature; TU-11,
TU-12, and TUG-2 in ITU nomenclature) are analogous.
The VT/VC mapper supports the following mappings:
28 asynchronous, byte-, or bit-synchronous DS1 signals
are mapped into seven VT groups or TUG-2s.
28 asynchronous, byte-, or bit-synchronous J1 signals
are mapped into seven VT groups or TUG-2s.
21 asynchronous, byte-, or bit-synchronous E1 signals
are mapped into seven VT groups or TUG-2s.
Maps DS1 into VT1.5/TU-11/TU-12, J1 into VT1.5/TU-11/
TU-12, and E1 into VT2/TU-12.
ADM applications are supported via tributary loopback,
tributary pointer processing, and a low-order path overhead
access channel.
The VT/TU mapper supports automatic generation or
microprocessor overwrite of 1-bit RDI-V, enhanced RDI-V,
1-bit RFI-V, automatic downstream AIS generation, and five
J2 trace identifier modes.
The VT/TU mapper complies with GR-253-CORE, G.707,
T1.105, G.704, G.783, JT-G707, GR-499, and ETS 300
417-1-1.
5.7.1 Receive Direction
In the receive direction, the VT mapper terminates the data
stream it receives from the SPE mapper. It demultiplexes
the AU-3/TUG-3 into the VTs/TUs and checks the H4
multiframe alignment. A pointer interpreter for up to
28 VTs/TUs detects LOP, AIS, NDF, NORM, INC, and DEC
on each channe l.
The low-order path termination includes V5 byte
termination, J2 path trace, Z6/N2 tandem connection,
Z7/K4 enhanced RDI-V and low-order APS monitoring, and
the payload termination for asynchronous, byte- or bit-
synchronous signals. The V5 byte termination performs
BIP-2 check (bit or block mode), REI-V count, RFI-V, and
RDI-V detection, signal label monitoring, and automatic
AIS-V insertion (which can be inhibited).
The J2 monitor supports the following modes:
Cyclic check
SONET framing mode
SDH framing mode
Single byte check
In byte-synchronous mode, the receive demapper
generates a frame synchronization signal to indicate the
DS1 frame bit or the MSB of the E1 time slot 0. Additionally,
it provides the framer access to the received signaling bits.
Output of the VT mapper is a DS1/J1/E1 signal with a
gapped clock. It can be overwritten with AIS automatically
or upon microprocessor request.
5.7.2 Transmit Direction
In the transmit direction, the VT mapper gets a clock, data,
and frame synchronization signal from the multirate cross
connect. The input is retimed and is checked for a digital
loss of clock (LOC), an AIS condition, and low zeros
density. In byte-synchronous mode, the input signal is
additionally checked for loss-of-frame (LOF).
Agere Systems Inc. 17
Product Description TMXL33625 HypermapperLite
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
5 Block Description (continued)
A transmit elastic store synchronizes the incoming
DS1/J1/E1 signals to the local STS-1 clock. In
asynchronous and bit-synchronous mode, it works as a bit-
oriented (64-bit) FIFO, and in byte-synchronous mode, as a
byte- wide (8-byte) buffer using a V5 byte marker bit (8-bit).
Overflow or underflow conditions are monitored and
reported.
In asynchronous and bit-synchronous mode, a fixed VT
pointer of 78 (VT1.5/TU-11) or 105 (VT2/TU-12) is
generated and the payload is mapped into the container
using a positive/null/negative bit stuffing mechanism
(C-bits and S-bits). In bit-synchronous mode, the bit stuffing
mechanism is disabled. In byte-synchronous mode, a
dynamic VT pointer value is generated using the V5
marker, implementing NORM, NDF, INC, and DEC
pointers.
The VT POH generation comprises V5 byte with BIP-2
generation, AIS-V, UNEQ-V insertion, automatic REI-V,
RFI-V, RDI-V, and enhanced RDI-V generation (Telcordia,
ITU-T), J2 path trace insertion via the microprocessor, Z6/
N2 byte insertion, and Z7/K4 byte insertion via the
microprocessor or low-order path overhead (LOPOH)
access channel.
The data stream is synchronized to the received internal
2 kHz synchronization pulse and is multiplexed to form the
STS-1/AU-3 signal, which is then output to the SPE
mapper.
When operating in byte-synchronous mode, the phase and
signaling bits from the framer are stored and inserted into
the mapped frame.
5.8 M13/E13 Multiplexer (M13/E13 MUX) Blocks
The M13/E13 block (12 blocks per device) is a highly
configurable multiplexer/demultiplexer for which each block
can be configured for M13 or E13 operation. The features
are as described below.
5.8.1 M13 MUX
The M13 may operate in the C-bit parity or M23 mode. In
the C-bit parity mode, the M13 provides a far-end alarm
and control (FEAC) code generator and receiver, an HDLC
transmitter and receiver, and an automatic far-end block
error (FEBE) generator.
28 DS1 inputs (in groups of four) or 21 E1 input signals (in
groups of three) can feed into individual M13 MUXs.
The M13 supports numerous automatic monitoring
functions. It can provide an interrupt to the control system,
or it can operate in a polled mode.
The M13 complies with T1.102, T1.107, T1.231, T1.403,
T1.404, GR-499, G.747, and G.775.
5.8.1.1 Receive Direction
The receive DS3 is monitored for loss of clock and loss of
signal (LOS) according to T1.231. The B3ZS decoder
accepts either the unipolar clock and data, or unipolar clock
and positive and negative data. It also checks for bipolar
coding violations. The transmit DS3 can be looped back
into the receive side after B3ZS decoding. The M23
demultiplexer checks for valid DS3 framing by finding the
frame alignment pattern (F-bits) and then locating the
multiframe alignment signal (M-bits). During each M frame,
the data stream is checked for the presence of the AIS
(1010) or idle (1100) pattern.
Within the M13 demultiplexer, there are four performance
monitoring counters for F- or M-bit, P-bit, E-bit parity, and
FEB E e r ro rs.
5.8.1.2 Transmit Direction
The incoming DS1/E1 clocks are first checked for activity or
loss-of-clock (LOC). The data signals are retimed and
checked for AIS and activity. DS1/E1 loopback selectors
allow the individual DS1/E1 signals within the received DS3
to be looped back toward the DS3 input. This loopback can
be performed automatically, or the user can force a DS1 or
E1 loopback.
The four DS1 or three E1 signals for each M12 MUX are
fed into single-bit, 16-word-deep FIFOs to synchronize the
signals to the DS2 frame generation clock. The fill level of
each FIFO determines the need for bit stuffing its DS1/E1
input. The M13 can handle DS1/E1 signals with nominal
frequency offsets of ±130 ppm and up to five unit intervals
peak jitter. The DS3 transmit clock is used to derive the
clock source for DS2 frame generation.
The transmit DS3 output can either be in the form of
unipolar clock and data, or unipolar clock and positive and
negative data. The DS3 data is B3ZS-encoded and can be
looped back from the receive DS3 input.
1818 Agere Systems Inc.
Product Description
February 21, 2003
622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
5 Block Description (continued)
5.8.2 E13 MUX
The E13 is a functional block that performs MUX/deMUX
from/to 16 E1s and one E3 signal compliant with ITU G.742
and ITU G.751. The E13 functional block is a highly
configurable multiplexer/demultip lexer. Each internal E12
MUX/deMUX and E23 MUX/deMUX is independently
configurable. The E3 inputs to the receive path can be
HDB3-encoded dual-rail (bipolar) signals or already
decoded single-rail signals with or without a BPV indication
input. The E1 inputs are expected to be decoded prior to
the E13 functional block. E3 transmit direction output can
be configured as HDB3-encoded dual rail (bipolar) or as
single rail. The E13 provides status and two-level priority
maskable interrupt outputs to the microprocessor.
E1 transmit path monitors detect loss of clock (LOC) and
AIS. The E3 receive monitor detects loss of signal (LOS),
loss of clock (LOC), bipolar violations (BPV), AIS, and RAI.
E3 and E2 loopback modes are also available.
5.9 Multirate Cross Connect (MRXC) Block
The multirate cross connect (MRXC) functional block (four
per device) is a crosspoint switch for DS1/J1/E1, DS3/E3,
and path overhead I/O. The multirate cross connect routes
signals to/from the major functional blocks and external I/O
pins as necessary for each application. The MRXC can
multicast, route test patterns, idles, or alarm conditions to
any channel, and provide system loopbacks.
The multirate cross connect can interconnect up to 84
individual DS1/E1 channels between the framer, M13/E13
multiplexer, VT mapper, or jitter attenuator.
Independent signal paths for remote alarm indication (RAI),
alarm indication signal (AIS), and byte-synchronous frame
synchronizing signals on channels between the VT mapper
or M13/E13 and the framer are supported. Receive pointer
adjustment information is routed to the jitter attenuator
functional block for each channel originating in the VT
mapper.
For DS3/E3 signals, the multirate cross connect supports
configuration of interconnects between the following:
The M13/E13 and the SPEMPR
External I/O interconnection to the M13/E13 or SPEMPR
Insertion/monitoring of unframed test patterns from the
test-pattern generator/monitor functional block
The test-pattern generator/monitor functional block (TPG/
TPM) provides test signals and monitors inputs for signals
to/from the multirate cross connect. The TPG can generate
a set of test signals at DS1, E1, and DS3, E3, or
STS-1 rates. There is only one test pattern generator and
monitor per signal rate.
For overhead, the MRXC provides an access channel
connection (TOAC and POAC) to the SPEMPR or to the
TMUX functional blocks.
The MRXC also provides the interface to the external pins.
The external pins may be configured to work in two modes:
a transport mode and a network serial multiplexed interface
(NSMI) mode. The first mode is used to provide dedicated
access to the device for DS3/E3 signals, and the NSMI
mode is described below.
Network serial multiplexed bus (NSMI):
6- or 8-pin serial interface.
Transmit and receive clock and data at 51.84 MHz (or
44.736/34.368 MHz for M13/E13).
Accommodates one STS-1 SPE.
Provides a minimal pin count interface for data and
inverse multiplexing for ATM (IMA) applications
without slip buffers.
Two modes of operation:
! M13/E13—proprietary transport format with DS3/
E3 framing.
! SPE—proprietary transport format mapped into an
STS-1/AU-3.
Agere Systems Inc. 19
Product Description
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
5 Block Description (continued)
5.10 DS1 Digital Jitter Attenuator (DS1/E1 DJA)
Block
The DS1/E1 digital jitter attenuator (DS1/E1 DJA) block (12
per device), contains 28 copies of the digital jitter
attenuator for a total of 336/252 DS1/E1 DJAs. These
digital jitter attenuator functional blocks can operate in two
different modes: as a DS1 or as an E1 jitter attenuator.
In both modes, the digital jitter attenuator can be
provisioned to always operate as a second-order PLL, or it
can switch to act as a first-order PLL during VT pointer
adjustments to help meet MTIE requirements. The period
of time in the first-order mode is provisionable. The PLL
bandwidth is provisionable between 0.1 Hz and 0.5 Hz, and
the damping factor for these bandwidths varies between 2
and 0.5 to accommodate a number of different system
constraints.
The DS1/E1 DJA allows automatic pass-through of an AIS
from both the VTMPR and M13/E13 blocks.
5.11 DS3 Digital Jitter Attenuator (DS3/E3 DJA)
Block
The HypermapperLite device contains four DS3/E3 digital
jitter attenuator blocks containing six DS3/E3 digital jitter
attenuators each. These digital jitter attenuators can
operate in two different modes: as a DS3 or as an E3 jitter
attenuator. The PLL bandwidth and the sampling ratio can
be set over a wide range to accommodate a number of
different system co nstraints.
The DJA functional block accepts/delivers DS3/E3 clock
and data from/to the multirate cross connect functional
block. The PLL bandwidth, damping factor, and sampling
rates are programmable. Output is programmable as data
only, as B3ZS-coded, or as HDB3-coded.
5.12 Test Pattern Generator/Monitor (TPG/TPM)
Block
The test pattern generator/test pattern monitor functional
block (TPG/TPM) consists of a set of configurable test
pattern generators and monitors for local self-test,
maintenance, and troubleshooting operations.
The TPG feeds one or more DS1/E1 test signals (via data,
clock, and FS or AIS signal paths) to the multirate cross
connect, which can redistribute or broadcast these signals
to any valid channel in the framer, M13/E13 MUX, or VT
mapper functional blocks. The TPG can also generate
DS3, E3, or STS-1 test signals.
Any channel arriving at the multirate cross connect can be
routed to the test monitor. The test monitor can
automatically detect/count bit errors in a pseudorandom
test sequence, loss of frame (DS1/E1 only), or loss of
synchronization situation. The TPM can provide an
interrupt to the control system, or it can be operated in a
polled mode.
Simultaneous testing of DS1, E1, and DS3, E3, or STS-1
signals is supported with one channel for each (one
channel shared between DS3, E3, and STS-1).
Supported test patterns are a quasirandom signal (QRSS),
a pseudorandom bit sequence (PRBS23, PRBS20,
PRBS15), alternating zeros/ones, an all-ones pattern, and
a 16-bit user-provisionable pattern.
The DS1 and E1 test patterns can be transmitted as either
unframed or as the payload of a framed signal, as defined
in ITU-T Recommendation O.150. DS3, E3, or STS-1
patterns are unframed only.
Under register control, single bit-errors can be injected into
any test pattern.
5.13 Low-Orde r Pa th Over Head
This block is shown in Figure 1, but it cannot be addressed
by the MPU. It is shown as a virtual block to highlight that
the LOPOH bytes from the TMUX, SPEMPR, and VTMPR
can be provisioned to appear at the LOPOH device pins.
Provisioning is accomplished by setting registers in the
device via the MPU.
2020 Agere Systems Inc.
Product Description
February 21, 2003
622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
5 Block Description (continued)
5.14 Framer Block
Functionalities present in each subcomponent of the DS1/
J1/E1 fr amers are shown below.
5.14.1 Receive Frame Aligner/Transmit
Frame Formatter
The receive frame aligner and transmit frame formatter
support the following frame formats:
D4 superframe
SF D4 superframe: FT framing only
J-D4 superframe with Japanese remote alarm
DDS
SLC-96
ESF
J-ESF (J1 standard with different CRC-6 algorithm)
Nonalign DS1 (193 bits—clear channel)
CEPT basic frame (ITU G.706)
CEPT CRC-4 multiframe with 100 ms timer (ITU G.706)
CEPT CRC-4 multiframe with 400 ms timer (automatic
CRC-4/non-CRC-4 equipment interworking) (ITU G.706
Annex B)
Nonalign E1 (256 bits—clear channel)
2.048 coded mark inversion (CMI) coded interface (TTC
standards JJ-20.11)
5.14.2 Receive Performance Monitor
The receive performance monitor detects the following
alarms:
Loss of receive clock
Loss-of-frame
Alarm indication signal (AIS)
Remote frame alarms
Remote multiframe alarms
These alarms are detected as defined by the appropriate
ANSI, AT&T, ITU, and ETSI standards.
Performance monitoring, as specified by AT&T, ANSI, and
ITU, is provided through counters monitoring the following:
Frame bit errors
CRC errors
Errored eve n ts
Errored seconds
Bursty errored seconds
Severely errored seconds
In-band loopback activation and deactivation codes can be
transmitted to the line via the payload or the facility data
link. In-band loopback activation and deactivation codes in
the payload or the facility data link are detected.
5.14.3 Signaling Processor
The signaling processor supports the following modes:
Superframe (D4, SLC-96): 2-state, 4-state, and 16-state
VT 1.5 SPE: 2-state, 4-state, and 16-state
Extended superframe: 2-state, 4-state, and 16-state
CEPT: common channel signaling (CCS) (TS-16)
Transparent (pass thro ugh ) signa li ng
J-ESF handling groups
Signaling features supported per channel are as follows:
Signaling debounce
Signaling freeze
Signaling interrupt upon change of state
Signaling inhibit
Signaling stomp
Voice and data channels are programmable in the DS1
robbed-bit signaling modes. The entire payload can be
forced into a data-only (no signaling channels) mode
(i.e., transparent mode, achieved by programming one
control bit).
Signaling access occurs through the on-chip signaling
registers.
Agere Systems Inc. 21
Product Description
February 21, 2003 622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
5 Block Description (continued)
5.14.4 Facility Data Link (FDL) Processor
The receive facility data link processor monitors the bit-
oriented ESF data-link messages defined in ANSI T1.403.
The transmit facility data link unit overrides the FDL-FIFO
for the transmission of the bit-oriented ESF data-link
messages defined in ANSI T1.403-1995.
The FDL processor extracts and stores data link bits from
three different frame types as follows:
D-bits and delineator bits from the SLC-96 multi-
superframe.
Data link bits from DDS frames (bit 6 of time slot 24).
Two multiframes of Sa[4:8] bits from timeslot 0 in CEPT
basic and CRC-4 multiframes.
The respective bits are always extracted from frame-
aligned frames and are stored in a stack. The processor
controls notification of stack updates through the interrupt
(maskable) registers.
The transmit FDL functional block performs the
transmission of D-bits into SLC-96 Superframes, Sa-bits in
CEPT frames, and D-bits in DDS frames.
In SLC-96 frames, the D and delineator bits are always
sourced from this functional block when the block is
enabled for insertion.
In DDS frames, the data link bits are always sourced
from this functional block when this block is enabled for
insertion. This functional block also provides the
capability to transmit BOMs (bit-oriented messages) in
the data link channel of ESF links.
In CEPT frames, the Sa bits are sourced from the Sa
stack within this functional block. The data link functional
block only responds with valid data when selected by the
Sa source control bits.
5.14.5 HDLC Unit
The HDLC processor formats th e HDLC packets for
insertion into the programmable channels. A channel can
be any number of bits (1 to 8) from a time slot.
The maximum number of channels is 64. The maximum
channel bit rate is 64 kbits/s. The minimum channel bit rate
is 4 kbits/s. Each channel is allocated 128 bytes of storage.
HDLC processing of data on the facility data link (PRMs,
Sa-bits, or otherwise) is implemented by assigning the FDL
bit position to a logical HDLC channel.
Agere Systems Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application.
Agere, Agere Systems and the Agere logo are trademarks of Agere Systems Inc.
Copyright © 2003 Agere Systems Inc.
All Rights Reserved
March 06, 2003
DS03-078BBAC (Replaces DS03-052B BAC)
For additional information, contact your Agere Systems Account Manager or the following:
INTERNET: http://www.agere.com
E-MAIL: docmaster@agere.com
N. AMERICA: Agere Systems Inc., Lehigh Valley Central Campus, Room 10A-301C, 1110 American Parkway NE, Allentown, PA 18109-9138
1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 61 0-712-4106)
ASIA: Agere Systems Hong Kong Ltd., Suites 3201 & 3210-12, 32/F, Tower 2, The Gateway, Harbour City, Kowloon
Tel. (852) 3129-2000, FAX (852) 3129-2020
CHINA: (86) 21-5 047-1212 (Shanghai), (86) 755-25881122 (Shenzhen)
JAPAN: (81) 3-5421-1600 (Tokyo), KORE A: (82) 2-767-18 50 (Seoul), SINGAPORE: (65) 778-88 33, TAIWAN: (886) 2-2725 - 5858 (Taipei)
EUROPE: Tel. (44 ) 134 4 296 400
Product Description
February 21, 2003
622/155 Mbits/s SONET/SDH x DS3/E3
TMXL33625 HypermapperLite
6 Glossar y
AIS Alarm indication signal
AMI Alternate mark inversion
APS Automatic protection switch
ASM Associated signaling mode
BER Bit error rate
BLSR Bidirectional line switching ring
BOM Bit-oriented me ssage
BPV Bipolar violation
B8ZS Bipolar 8 zero substitution
CCI Common channel signaling
CDR Clock and data recovery
CHI Concentrated highway interface
CMI Coded mark inversion
CRC Cyclic redundancy check
CRV Coding rule violation
DACS Digital acc es s cr os s co nne cts
DJA Digital jitter attenuation
ESF Extended superframe
EXZ Excessive zeros
FCS Frame ch eck seq uenc e
FDL Facility data link
FEAC Far-end alarm and control
FEBE Far-end block error
HDB3 High-density bipolar of order three
HDLC High-level data link control
LIU Line inter fac e unit
LOC Loss-of-clock
LOF Loss-of-frame
LOS Loss of signal
LOPOH Low-order path overhead
OOF Out of frame
MCDR Mate clock and data recovery
MRXC Multirate cross connect
NSMI Network serial multiplexed interface
PBGA Plastic ball grid array
POAC Path overhead access channel
PRBS Pseudorandom bit sequence
PRM Performance report message
QRSS Quasirandom signal source
RAI Remote alarm indicator
RDI Remote defect indication
REI Remote error indication
SDH Synchronous digital hierarchy
SEF Severely errored frame
TCM Tandem connection monitoring
TOAC Transport overhead access channels
UPSR Unidirectional path s witch ring
Telcordia and Telcordia Technologies are registered trademarks of Telcordia Technologies, Inc.
ANSI is a registered trademark of American National St andards Institute, Inc.
SLC is a registered trademark of Lucent Technologies Inc.
AT&T is a registered trademark of AT&T in the USA and other countries.
IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Inc.