HRP-100 100W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function High efficiency up to 90% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Protections: Over temperature (optional) Cooling by free air convection 1U low profile 38mm Built-in remote ON-OFF control No load power consumption<0.5W All using 105 long life electrolytic capacitors 5 years warranty Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION MODEL OUTPUT UL62368-1 HRP-100-5 HRP-100-7.5 HRP-100-12 HRP-100-15 HRP-100-24 HRP-100-36 HRP-100-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 20A 17A 13.5A 8.5A 7A 4.5A 2.9A 2.2A CURRENT RANGE 0 ~ 20A 0 ~ 17A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.9A 0 ~ 2.2A RATED POWER 66W 85W 101.3W 102W 105W 108W 104.4W 105.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.8V 2.5% 7.1 ~ 9V 2.5% 11.4 ~ 13.8V 1.5% 14.25 ~ 18V 1.5% 22.8 ~ 28.8V 1.5% 34.2 ~ 39.6V 1.5% 45.6 ~ 55.2V 1.5% 3.1 ~ 3.8V VOLTAGE TOLERANCE Note.3 +2.5,-3.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 2.0% 2.0% 1.5% 0.8% 0.8% 0.5% 0.5% 0.5% SETUP, RISE TIME 2500ms, 100ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC 88% 88.5% 89% 90% PROTECTION FUNCTION 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC 35A/115VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD OVER VOLTAGE 2500ms, 100ms/115VAC at full load 20ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT EN62368-1 TPTC004 IEC62368-1 HRP-100-3.3 PF>0.98/115VAC at full load 83% 84% 87.5% 0.6A/230VAC 65A/230VAC 105 ~ 135% rated output power Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE REMOTE CONTROL Shut down o/p voltage, recovers automatically after temperature goes down RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off WORKING TEMP. -40 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH 0.04%/ (0 ~ 50) TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION OTHERS NOTE 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1,TUV EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020 MTBF 295.7K hrs min. DIMENSION 159*97*38mm (L*W*H) PACKING 0.56Kg; 24pcs/15Kg/0.76CUFT MIL-HDBK-217F (25) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:HRP-100-SPEC 2020-02-12 HRP-100 100W Single Output with PFC Function I I Mechanical Specification Case No.901I series Unit:mm 3.5 7 152.5 1 3 8.2 5 2-M 6 3L 84.5 4 =4 97 65 9.5 2 1 2 7 .5 3 4.5 Terminal Pin No. Assignment 78 24 Pin No. Assignment 4,5 DC OUTPUT -V 6,7 DC OUTPUT +V 159 6.5 150 Terminal JST XHP or equivalent JST SXH-001T or equivalent 3.5 6-M3(Both Sides) L=6 22 38 Mating Housing 28.5 18 Assignment RCRC+ .5 Pin No. 1 2 3 10 max. Remote ON/OFF (CN100) : JST B-XH or equivalent 18.5 9 Assignment AC/L AC/N FG 9 Pin No. 1 2 3 CN100 SVR1 117 Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER +V -V DETECTION CIRCUIT FG PFC CONTROL O.V.P. PWM CONTROL Derating Curve RC+ REMOTE CONTROL RC- Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -40 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRP-100-SPEC 2020-02-12