T13-212 Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Screw terminals Description - Applications Threaded neck type Thermal circuit breaker 1pole Reset type Wide current range High breaking capacity Bolts and nuts - Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for product, Product News Unique Selling Proposition - Power supplies Uninterruptible power supply Power tools Household appliances Compact design Positively trip-free release Available with cover Different mounting possibilities Standards -IEC 60934 -UL 1077 -CSA C22.2 No. 235 -GB 17701 Technical Data Rated Voltage AC Rated Voltage DC Rated current range AC Conditional short circuit capacity Short circuit capacity Icn Degree of Protection Dielectric Strength Insulation resistance Endurance typical Endurance minimum 240/277 V; 50/60 Hz, see approbations 28 V 0.05 - 30 A IEC: Inc, PC1, AC 240 V: 1 kA at In < 7 A/240 VAC : 8 x In at In 7 A/240 VAC : 400 A AC/DC 28 V : 400 A from front side IP 40 acc. to IEC 60529 50 Hz: 1.5 kV Impulse 1.2/50 s: > 2.5 kV 500 VDC > 100 M 2 x Ir: 3000 switching cycles Reset type AC : 2 x Ir , cos 0.6 : DC : 2 x Ir , L/R = 2 - 3 ms : 50 switching cycles Overload Ambient temperature Vibration Resistance Shock Resistance Tripping Type Actuation type Weight IEC: min. 40 trips @ 6 x Ir, cos 0.6 UL / CSA: min. 50 trips @ 1.5 x Ir, cos 0.75 -5 C to 60 C 1.5 mm @ 10 - 60 Hz acc. to IEC 60068-2-6, test Fc 10 G @ 60 - 500 Hz acc. to IEC 60068-2-6, test Fc 100 G / 6 ms acc. to IEC 60068-2-27, test Ea Thermal Reset type ca. 10 g Circuit Breakers 1 T13-212 Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Dimension T13-212 1 2 3/8-27UNS-2A O 13 8.8 6.3 45 - 0.3 8 20 16 O5 M4 20.4 +0.4 11.5 - 0.2 31 - 0.0 16 O9 .6 8.9 +0.1 - 0.0 Diagrams T13-... 1 2 2 Circuit Breakers 11.5 T13-212 Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Approvals Approval Rated current Rated voltage AC Rated voltage DC UL 1077 0.05...30 A 277 V 28 V CSA C22.2 No. 235 0.05...30 A 277 V 28 V EN 60934 0.05...30 A 240 V - GB 17701 0.05...30 A 240 V - Typical internal resistance Rated Current [A] Internal Resistance [] 0.05 376.500 0.50 4.40 1.00 1.10 2.00 0.31 3.00 0.14 4.00 0.068 5.00 0.048 6.00 0.033 8.00 0.026 9.00 0.0125 10.00 0.0125 11.00 0.0085 12.00 0.0085 13.00 0.0085 14.00 0.007 15.00 0.007 16.00 0.007 17.00 0.0047 18.00 0.0047 19.00 0.0047 20.00 0.004 21.00 0.0035 22.00 0.003 23.00 0.003 24.00 0.003 25.00 0.003 26.00 0.0022 27.00 0.002 28.00 0.002 29.00 0.002 30.00 0.002 Circuit Breakers 3 T13-212 Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Time-Current-Curves [ min ] [ sec] 10'000 < 7,0 A > 7,0A 60 30 20 2000 1000 10 500 5 200 Time in Seconds 100 1 50 20 10 5 2 1 0,5 0, 3 0, 2 0,1 1,05 1,32 2 3 4 5 8 10 Multiple of Rated Current In Reference Temperature +23 Effect of ambient temperature The units are calibrated for an ambient temperature of +23C. To determine the rated current for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient temperature [C] Correction factor -5 0.88 0 0.90 10 0.95 23 1.00 30 1.05 40 1.10 50 1.18 60 1.26 Example: Rated current = 5 A; Environmental temperature = 40 C; --> Correction factor = 1.1; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A Config. Code T13|-|1|2|3|B|-|1.23| The characters are placeholders for the correspondingly keys of selections from the key tables. T13|-| 1 |2|3|B|-|1.23| = Mounting T13|-|1|2| 3 |B|-|1.23| = Terminal Mounting Configuration key Threaded neck type with knurled nut 2 T13|-|1| 2 |3|B|-|1.23| = Actuation type Actuation type 4 1 Circuit Breakers Screw clamp terminals Configuration key 2 T13|-|1|2|3| B |-|1.23| = Setting indication Configuration key Reset type Terminal Setting indication Setting indication Configuration key R T13-212 Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 T13|-|1|2|3|B|-| 1.23 | = Rated current Rated current Rated current Configuration key 0.05 A 0.05 0.1 A 0.1 0.15 A 0.15 0.2 A 0.2 0.3 A 0.3 0.4 A 0.4 0.5 A 0.5 0.6 A 0.6 0.7 A 0.7 0.8 A 0.8 0.9 A 0.9 1.0 1 1.1 A 1.1 1.2 A 1.2 1.3 A 1.3 1.4 A 1.4 1.5 A 1.5 1.6 A 1.6 1.7 A 1.7 1.8 A 1.8 1.9 A 1.9 2.0 A 2 2.1 A 2.1 2.3 A 2.3 2.5 A 2.5 2.8 A 2.8 3.0 A 3 3.3 A 3.3 Configuration key 3.5 A 3.5 4.0 A 4 4.5 A 4.5 5.0 A 5 5.5 A 5.5 6.0 6 6.5 A 6.5 7.0 A 7 7.5 A 7.5 8.0 A 8 8.5 A 8.5 9.0 A 9 9.5 A 9.5 10.0 A 10 11.0 A 11 12.0 A 12 13.0 A 13 14.0 A 14 15.0 A 15 16.0 A 16 17.0 A 17 18.0 A 18 19.0 A 19 20.0 A 20 22.0 A 22 25.0 A 25 28.0 A 28 30.0 A 30 Other rated currents on request Other rated currents on request Variants Rated current Setting indication Config. Code Order Number 16.0 A T13-212-16 4411.0012 30.0 A T13-212-30 4411.0067 12.0 A T13-212-12 4411.0099 11.0 A l T13-212R-11 4411.0210 15.0 A l T13-212R-15 4411.0211 Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/ Stock-Check-SCHURTER Packaging Unit 20 Pcs Circuit Breakers 5 T13-212 Thermal (T- and TA-Line) www.schurter.com/PG17_18_19 Accessories Description 31.05.2016 T-Linie Zubehor Accessories to T-Line 6 Circuit Breakers The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schurter: 4411.0042 4411.0043 4411.0067 4411.0076 4411.0099 4411.0214 4411.0233 4411.005 4411.0050