ADS-919
3
➄
This is the time required before the A/D output data is valid after the analog input
is back within the specified range.
+25°C 0 to +70°C –55 to +125°C
ANALOG OUTPUT MIN. TYP. MAX. MIN. TYP. MAX. MIN. TYP. MAX. UNITS
Internal Reference
Voltage +9.95 +10 +10.05 +9.95 +10 +10.05 +9.95 +10 +10.05 Volts
Drift — ±5 — — ±5 — — ±5 — ppm/°C
External Current — — 1.5 — — 1.5 — — 1.5 mA
DIGIT AL OUTPUTS
Logic Levels
Logic "1" +2.4 — — +2.4 — — +2.4 — — Volts
Logic "0" — — +0.4 — — +0.4 — — +0.4 Volts
Logic Loading "1" — — –4 — — –4 — — –4 mA
Logic Loading "0" — — +4 — — +4 — — +4 mA
Delay, Falling Edge of EOC
to Output Data Valid — — 35 — — 35 — — 35 ns
Output Coding Straight Binary
POWER REQUIREMENTS, ±15V
Power Supply Ranges
+15V Supply +14.5 +15 +15.5 +14.5 +15 +15.5 +14.5 +15 +15.5 Volts
–15V Supply –14.5 –15 –15.5 –14.5 –15 –15.5 –14.5 –15 –15.5 Volts
+5V Supply +4.75 +5 +5.25 +4.75 +5 +5.25 +4.75 +5 +5.25 Volts
Power Supply Currents
+15V Supply — +45 +60 — +45 +60 — +45 +60 mA
–15V Supply — –45 –60 — –45 –60 — –45 –60 mA
+5V Supply — +85 +95 — +85 +95 — +85 +95 mA
Power Dissipation — 1.8 2.2 — 1.8 2.2 — 1.8 2.2 Watts
Power Supply Rejection — — ±0.02 — — ±0.02 — — ±0.02 %FSR/%V
POWER REQUIREMENTS, ±12V
Power Supply Ranges
+12V Supply +11.5 +12 +12.5 +11.5 +12 +12.5 +11.5 +12 +12.5 Volts
–12V Supply –11.5 –12 –12.5 –11.5 –12 –12.5 –11.5 –12 –12.5 Volts
+5V Supply +4.75 +5 +5.25 +4.75 +5 +5.25 +4.75 +5 +5.25 Volts
Power Supply Currents
+12V Supply — +45 +65 — +45 +65 — +45 +65 mA
–12V Supply — –45 –60 — –45 –60 — –45 –60 mA
+5V Supply — +85 +95 — +85 +95 — +85 +95 mA
Power Dissipation — 1.5 1.7 — 1.5 1.7 — 1.5 1.7 Watts
Power Supply Rejection — — ±0.02 — — ±0.02 — — ±0.02 %FSR/%V
Footnotes:
➀
All power supplies must be on before applying a start convert pulse. All supplies
and the clock (START CONVERT) must be present during warmup periods. The
device must be continuously converting during this time. There is a slight
degradation in performance when using ±12V supplies.
➁
See Ordering Information for availability of ±5V input range. Contact DATEL for
availability of other input voltage ranges.
➂
A 2MHz clock with a 200ns wide start convert pulse is used for all production
testing. See Timing Diagram for more details.
6.02
(SNR + Distortion) – 1.76 + 20 log Full Scale Amplitude
Actual Input Amplitude
➃
Effective bits is equal to:
TECHNICAL NOTES
1. Obtaining fully specified performance from the ADS-919
requires careful attention to pc-card layout and power
supply decoupling. The device's analog and digital ground
systems are connected to each other internally. For optimal
performance, tie all ground pins (14, 19 and 23) directly to a
large analog ground plane beneath the package.
Bypass all power supplies and the REFERENCE OUTPUT
(pin 21) to ground with 4.7µF tantalum capacitors in parallel
with 0.1µF ceramic capacitors. Locate the bypass capaci-
tors as close to the unit as possible. If the user-installed
offset and gain adjusting circuit shown in Figure 2 is used,
also locate it as close to the ADS-919 as possible.
2. The ADS-919 achieves its specified accuracies without the
need for external calibration. If required, the device's small
initial offset and gain errors can be reduced to zero using
the input circuit of Figure 2. When using this circuit, or any
similar offset and gain-calibration hardware, make adjust-
ments following warmup. To avoid interaction, always
adjust offset before gain.
3. When operating the ADS-919 from ±12V supplies, do not
drive external circuitry with the REFERENCE OUTPUT. The
reference's accuracy and drift specifications may not be
met, and loading the circuit may cause accuracy errors
within the converter.
4. Applying a start convert pulse while a conversion is in
progress (EOC = logic "1") initiates a new and inaccurate
conversion cycle. Data for the interrupted and subsequent
conversions will be invalid.