Hall Effect Current Sensors S22P Series
Tamura reserve the right to modify its products in order to improve them without prior notice
S22PXXXS05revD, April 2012
Issued by Module Components Div, TAMURA CORPORATION
-10
-8
-6
-4
-2
0
2
4
6
0.1 1 10 100
Attenuation (dB)
Frequency characteristic(kHz)
@ If=1(Arms)
Frequency characteristic(S22P025S05)
TA=25ºC, VCC=+5V, RL=10kΩ
Electrical Performances
Specifications
Features:
Closed Loop type
Voltage output
Unipolar power supply
Configurable integrated primary
Printed circuit board mounting
UL recognised - plastic case
material UL94V0
UL Recognition
Advantages:
Excellent accuracy and linearity
Low temperature drift
Wide frequency bandwidth
No insertion loss
High Immunity to external interferences
Optimised response time
Current overload capability
Parameters Symbol S22P006S05 S22P015S05 S22P025S05
Primary nominal current If 6A 15A 25A
Saturation current Ifmax ≥ ± 18A ≥ ± 45A ≥ ± 75A
Rated output voltage Vo Vof ±0.625V (at If)
Offset voltage1(at If=0A) Vof 2.5V±0.050V 2.5V±0.020V 2.5V±0.015V
Output voltage accuracy(at If) X 0.625V±0.010V(at If)
Output linearity2(0AIf) εL ≤±0.2% (at If)
Power supply voltage VCC +5V±5%
Consumption current3 ICC Typ. 12.5mA (at If=0A) + 37.5mA / 22.5mA / 9mA (at If = 75A / 45A / 18A)
Response time4 tr ≤ 1.0μs (at di/dt = 100A/ μs)
Thermal drift of gain5 TcVo ≤ ±0.05mV/ºC
Thermal drift of offset TcVof
-10ºC~25ºC : ≤±1.6mV/ºC
25ºC~85ºC : ≤±0.8mV/ºC
-10ºC~25ºC : ≤±0.6mV/ºC
25ºC~85ºC : ≤±0.3mV/ºC
-10ºC~25ºC : ≤±0.4mV/ºC
25ºC~85ºC : ≤±0.2mV/ºC
Hysteresis error VOH ≤0.5mV (at If=0AIf0A)
Insulation voltage Vd AC 3kV for 1minute (Sensing current 0.5mA) Primary Secondary
Insulation resistance RIS ≥ 500MΩ (at DC500V), primary secondary
Ambient operation temperature TA -10ºC~+85ºC
Ambient storage temperature TS -25ºC~+100ºC
1 After removal of core hysteresis 2 Without offset 3 Conversion ratio1:20004 Time between 90% input current full scale and 90% of sensor output full
scale 5 Without Thermal drift of offset
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
-100 -80 -60 -40 -20 0 20 40 60 80 100
Output voltage (V)
Input current (A)
Saturation characteristic(S22P025S05)
TA=25ºC Pulsed
Hall Effect Current Sensors S22P Series
Tamura reserve the right to modify its products in order to improve them without prior notice
S22PXXXS05revD, April 2012
Issued by Module Components Div, TAMURA CORPORATION
Mechanical dimensions
Electrical connection diagram
Package & Weight Information
Weight Pcs/box Pcs/carton Pcs/pallet
8g 100 400 12000
-If 4
5
6
3
2
1
7 8 9
+If
VOUT
GND
+VCC
RL = 10kΩ
+If / 3
+If / 2
+If
Connection diagram
UL Standard
UL 508 , CSA C22.2 No.14
(UL FILE No.E243511)
• For use in Pollution Degree 2 Environment.
• Maximum Surrounding air temperature rating, 85˚C.
1
2
3 4
5
6
IN OUT
Vcc
GND
Vout
5.5
23.50.5
22.2
3-(0.5×0.25)
5.08
12.7
10
0.8
2.54 2.54
7.66 5.08 7.6 1.9
3.5
0.7
24
Lot No
NOTES
1. Unit is mm
2. Tolerance is 0.5mm
⑨ ⑧ ⑦
⑥ ⑤ ④
③ ② ①
Terminal number:
1. IN-1 (Primary input current (+))
2. IN-2 (Primary input current (+))
3. IN-3 (Primary input current (+))
4. OUT-3(Primary input current (-))
5. OUT-2(Primary input current (-))
6. OUT-1(Primary input current (-))
7. VOUT
8. GND
9. +VCC(+5V)
RL