Fluke 3000 FC
Series Test Tools
Start building tomorrow’s test tool system
today with the Fluke 3000 FC Digital
Multimeter.
The new Fluke Connect system of test tools
communicates with the new Fluke Connect mobile
app on your Android or iOS smart device, allowing
you to share live measurements, monitor readings
from safe distances, and get your job done easier
than ever before. The wireless digital multimeter
functions as the mobile hub, displaying readings
from up to three module tools simultaneously from
up to 20 meters away. The Fluke Connect modules
also give you the flexibility to build your wireless
test tool system how you want when you want.
Fluke 3000 FC Test Tools
(Not compatible with Fluke CNX test tools)
Wireless Digital Multimeter
iFlex True-rms AC Current Clamp Module
True-rms AC Current Clamp Module
AC Voltage Module
K-Type Temperature Module
AC/DC Current Clamp Module
DC Voltage Module
PC Adapter
Productivity
Communicate with your iOS (4s and later) and
Android™ (4.3 and up) devices with the new Fluke
Connect mobile app
Wireless technology allows connectivity between
your phone, PC, and all Fluke Connect enabled test
tools
Let your team see what you see in an instant with
ShareLive video call
Save money and time by taking multiple measure-
ments simultaneously
Isolate intermittent events or record signal fluc-
tuations without even being there using the log
function on the modules
Now compatible with Fluke
Connect
Mobile App
Technical Data
Built with
See it. Save it. Share it.
All the facts, right in the field.
Smart phone not included with purchase.
Fluke Connect with ShareLive is the only wireless measurement system
that lets you stay in contact with your entire team without leaving the
field. The Fluke Connect mobile app is available for Android™ (4.3
and up) and iOS (4s and later) and works with over 20 different Fluke
productsthe largest suite of connected test tools in the world. And more
are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all
temperature, mechanical, electrical and vibration measurements for
each equipment asset in one place. Get started saving time and
increasing your productivity.
Download the app at:
2 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Productivity (continued)
View results on your computer with the PC Adapter
Work with fewer interruptions by recording multiple
sessions before downloading. Data is saved to a PC
in .csv format (comma separated variable) file format
for easy viewing at your convenience
Capture readings at different intervals, with user-set
recording intervals from one second to one hour
Future proof your investment by adding functionality
to the 3000 FC DMM when you need it
Convenience
Send and communicate test data to your manager
and coworkers to assess abnormal system response
in seconds
Have all asset test results at your fingertips after
downloading to your PC for future asset performance
tracking and reliability programs
See multiple measurements on one screen at one
time (DMM and three modules, Ti200/300/400 and
five modules)
No more writing data down. Capture up to 65000
sets of min/max/avg readings over single or multiple
logging sessions using the recording capability. Each
reading and session is time stamped
Avoid awkward or uncomfortable measurement posi-
tions. Set up the measurement once, step
back and read it as many times as you want, when
you want
View up to 6 live readings at once on the Fluke
Connect mobile app or a PC to get a complete
understanding of the situation
Easily see backlit displays in dark or dimly lit work
environments
Choose auto or manual ranging
Use the optional TPak Magnetic Hanger for even
more hands-free working
Integrated holster protects the meters, while probe
holders keep accessories organized
Safety
Be in multiple places at once, reducing the risk of
arc flash by separating yourself from hazardous
measurement situations
Fluke 3000 FC meets Measurement Category 1000
V CAT III and Category IV 600 V safety standards:
AC Current Clamp module and AC/DC Current Clamp
module 600 V CAT III; AC Voltage Module, DC Voltage
Module, and iFlex Clamp Meters 600 V CAT IV/1000
CAT III
(RF connection time (binding time) can take up to 1 minute.)
3 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke 3000 FC Series Wireless Multimeter
Detailed specifications (Not compatible with Fluke CNX test tools)
For all specifications: accuracy is specified for one year after calibration, at operating temper-
atures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take
the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
AC voltage
Range1Resolution
Accuracy2,3,4
45Hz to 500Hz 500Hz to 1kHz
600.0mV 0.1mV
1.0% + 3 2.0% + 3
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V
1 All ac voltage ranges are specified from 1% of range to 100% of range.
2 Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V.
3 For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.
DC voltage, continuity, resistance, diode test and capacitance
Function Range Resolution Accuracy
mV 600.0mV 0.1mV 0.09% + 2
V 6.000V 0.001V
0.09% + 260.00V 0.01V
600.0V 0.1V
1000V 1V 0.15% + 2
600Ω 1Ω Meter beeps at < 25Ω, beeper detects opens or shorts
of 250μs or longer.
600.0Ω 0.1Ω 0.5% + 2
6.000kΩ 0.001kΩ
0.5% + 1
60.00kΩ 0.01kΩ
60.00kΩ 0.1kΩ
600.0kΩ 0.001MΩ
50.00MΩ 0.01MΩ 1.5% + 3
Diode test 2.000V 0.001V 1% + 2
µF 1000nF 1nF
1.2% + 210.00μF 0.01μF
100.0μF 0.1μF
9999μF11μF 10% typical
1 In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2.
AC and DC current
Function Range1Resolution Accuracy
mA AC (45Hz to 1kHZ) 60.00mA 0.01mA 1.5% + 3
400.0mA30.1mA
mA DC260.00mA 0.01mA 0.5% + 3
400.0mA30.1mA
1 All ac current ranges are specified from 5% of range to 100% of range.
2 Input burden voltage (typical): 400mA input 2mV/mA.
3 400.0 mA accuracy specified up to 600mA overload.
Contents
General specifications
4 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Frequency
Range Resolution Accuracy [1]
99.99Hz 0.01Hz
0.1% + 1
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
1 Frequency is specified up to 99.99kHz in volts and up to 10kHz in amps.
Input characteristics
Function
Overload
Protection
Input Impedance
(nominal) Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V rms > 10 MΩ < 100 pF > 60 dB, dc to 60 Hz
1100 V rms > 10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale voltage Typical short circuit current
To 6 MΩ 50 MΩ
1100 V rms < 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 mA
1100 V rms < 2.7 V dc 2.000 V dc < 1.1 mA
Function Overload Protection Overload
mA Fused, 44/100A, 1000V FAST Fuse 600mA overload for 2minutes maximum, 10minutes rest minimum
MIN/MAX recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications (Not compatible with Fluke CNX test tools)
Maximum voltage between any
terminal and earth ground
1000 V dc or ac rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35°C to 40°C), 0% to 45% (40°C to 50°C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic compatibilty
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
5 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
a3000 FC general specifications
Range 0.5 A to 400.0 A
Resolution 0.1A
Accuracy 400.0 A: 2% ± 5 digits (10Hz to 100Hz), 2.5% ± 5 digits
(100Hz to 500Hz)
Inrush Max displayed reading: 999.9A
Crest factor (50Hz/60Hz) 3 at 500A, 2.5 at 600A, 1.42 at 1000A, add 2% for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1x (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
Altitude Operating: 2,000 m
Storage: 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
Safety rating CAT III 600 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP30
Pollution Degree 2
Jaw opening 34 mm (1.33 in)
Size (HxWxD) 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)
Weight .22 kg (8 oz)
Fluke a3000 FC Wireless AC Current Clamp Module
A fully functional true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect™ enabled master units, listed
below.
Fluke 3000 FC DMM
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3000 FC main features include:
True-rms ac clamp meter
Measure up to 400 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Inrush function
(Not compatible with Fluke CNX test tools)
6 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
a3001 FC general specifications
Fluke a3001 FC Wireless iFlex AC
Current Module
A true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect™ enabled master
units, listed below.
Fluke 3000 FC DMM
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
The iFlex™ Wireless Current Module allows you to mea-
sure around awkward sized conductors or get into tight
spaces and makes wire access easier.
Contains: One true-rms flexible current meter and one
iFlex i2500-10 Flexible Current Probe
Measure up to 2500 A ac
Use as a standalone meter or as part of the system
Logging function for recording and saving up to
65,000 readings
Inrush function
Magnetic hanging strap
Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3% ± 5 digits (5 Hz to 500 Hz)
Crest factor (50Hz/60Hz) 3.0 at 1100A, 2.5 at 1400A, 1.42 at 2500A, add 2% for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1X (specified accuracy)/ °C (<18°C or >28°C)
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
Altitude Operating: 2,000 m
Storage: 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Pollution
Degree 2
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution degree 2
Jaw opening 25.4 cm (10 in) coil
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
(Not compatible with Fluke CNX test tools)
7 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke a3002 FC Wireless AC/DC
Current Module
Designed to be used with the i410 or i1010 ac/dc current clamps (not included with
module). AC/DC current module that wirelessly relays measurements from the i410 or
i1010 clamp accessory to other Fluke Connect™ enabled master units, listed below.
Fluke 3000 FC DMM
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
a3002 FC main features include:
Measure up to 400 A ac or 400 A dc with i410 (sold separately)
Measure up to 600 A ac or 1000 A dc with i1010 (sold separately)
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Magnetic hanging strap
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative
humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least
significant digits ]). Dc ranges are autoranging. Ac accuracy is specified from 1 % to 110 % of the range.
dc accuracy is specified from -110 % to 110 % of range.
AC/DC current
Function Range Resolution Accuracy1
A dc 1000 A 0.1 A (0.5 % + 3)
A ac 600.0 A 0.1 A (1.0 % + 3)
1AC accuracy is specified from 45 Hz to 1000 Hz
Maximum voltage between
terminal and earth ground
(module)
30 V dc or ac rms
LCD w/backlight 3 ½ digits, 6000 counts, 4/sec update rate
Log rate/Interval Adjustable by PC from 1 sec to 1 hr, default 1 min
Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6
Battery life 400 hours minimum
Memory Record up to 65,000 readings
RF communications 2.4 GHz ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature coefficient 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
0 % to 45 % (40 °C to 50 °C)
EMC IEC 61236-1, Portable
Safety compliance Protected to IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition
Pollution Degree 2
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Size (HxWxD) 160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in)
Weight 0.255 kg (9 oz)
a3002 FC general specifications
(Not compatible with Fluke CNX test tools)
8 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke v3000 FC Wireless True-rms AC Voltage Module
A fully functional true-rms voltage meter that wirelessly relays ac voltage mea-
surements to other Fluke Connect™ enabled master units, listed below.
Fluke 3000 FC DMM
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
v3000 FC main features include:
True-rms ac voltage module
Measure up to 1000 V
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
TL224 Test Leads
AC285 Alligator Clips
Magnetic hanging strap
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are
autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging,
from 18 °C to 28 °C.
AC voltage
Range1Resolution Accuracy2,3,4
45Hz to 500Hz 500Hz to 1kHz
6.000V 0.001V
1.0% + 3 2.0% + 3
60.00V 0.01V
600.0V 0.1V
1000V 1V
1 All ac voltage ranges are specified from 1% of range to 100% of range.
2 Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor ≤ 1.5 at 1000V.
3 For non-sinusoidial waveforms, add –(2% of reading + 2% full scale) typical, for crest factor up to 3.
4 Do not exceed 106 V-Hz.
LCD w/backlight 3½ digits, 6000 counts, updates 4/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 Hours
Memory Record up to 65000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.1X (specified accuracy)/°C (< 18°C or > 28°C)
Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C
Altitude Operating: 2,000 m
Storage: 12,000 m
EMC EN 61326-1:2006
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
v3000 FC general specifications
(Not compatible with Fluke CNX test tools)
9 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke v3001 FC Wireless DC Voltage Module
A fully functional dc voltage meter that wirelessly relays dc voltage measurements to
other Fluke Connect™ enabled master units, listed below.
Fluke 3000 FC DMM
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
v3001 FC main features include:
Measure up to 1000 V dc
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
TL222 Test Leads
AC220 Alligator Clips
Magnetic hanging strap
v3001 FC general specifications
LCD w/backlight 3 ½ digits, 6000 counts, 4/sec update rate
Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6
Log rate/Interval Adjustable by PC from 1 sec to 1 hr, default 1 min
Battery life 400 hours minimum
Memory Record up to 65,000 readings
RF communications 2.4 GHz ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature coefficient 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
0 % to 45 % (40 °C to 50 °C)
EMC IEC 61236-1, Portable
Safety Compliance IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition
Pollution Degree 2
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Size (HxWxD) 160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in)
Weight 0.255 kg (9 oz)
DC voltage
Function Range Resolution Accuracy
mV dc 600.0 mV 0.1 mV 0.09 % + 3
V dc 6.000 V 0.001 V 0.09 % + 3
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15% + 2
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with rela-
tive humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of
least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by
autoranging, from 18 °C to 28 °C.
(Not compatible with Fluke CNX test tools)
10 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke t3000 FC Wireless K-Type Temperature Module
A versatile K-type thermocouple thermometer wirelessly relays
measurements to other Fluke Connect™ enabled master units, listed below.
Fluke 3000 FC DMM
Fluke Ti200/300/400 Infrared Camera
PC via optional pc3000 FC Adapter
Fluke Connect Mobile app
t3000 FC main features include:
K-type Thermocouple Thermometer
80PK-1 K-type Bead Thermocouple
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Magnetic hanging strap
Other K-type temperature probes also available
Range K-type: -200°C to 1372°C
Resolution 0.1°C
Accuracy ± [0.5% + 0.3°C] counts
Input terminals K-type mini
LCD w/backlight 3 ½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient 0.01% of reading +0.03°C per °C
Temperature scale ITS-90
Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C
Altitude Operating: 2,000 m
Storage: 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, CAT I, 3rd edition Pollution Degree 2
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
t3000 FC general specifications
(Not compatible with Fluke CNX test tools)
11 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke pc3000 FC Adapter and Software
Fluke 3000 FC Wireless Test Tools show real-time measurements
from remote modules up to 20 meters away on your PC
Fluke FC wireless test tools work together to help you troubleshoot faster.
The pc3000 FC Adapter and Software help you understand the information
you measure. When you need to get information back to a PC the
pc3000 FC Adapter and Software wirelessly collects up to 65,000 sets of
time stamped min/max/avg readings from FC remote modules. Software
can display live readings from up to six modules simultaneously. Allows
custom logging intervals and custom names for modules. Includes Windows
SW3000 software.
Software requirements:
Fluke pc3000 must be connected to the USB port in order to enable com-
munication between FC modules and software. SW3000 will support up to
two pc3000 FC Adapters.
OS Compatibility:
Windows XP or later.
Not compatible with Fluke CNX test tools
RF connection time (binding time) can be up to one minute for all FC
wireless tools.
12 Fluke Corporation Fluke 3000 FC Series Test Tools. The Fluke Wireless Team.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2014 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 3/2014 6002305A_EN
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. Keeping your world
up and running.®
Ordering information
Main units:
FLK-3000FC FC Wireless Digital Multimeter
Modules:
FLK-A3000FC FC Wireless AC Current Clamp Module
FLK-A3001FC FC Wireless iFlex AC Current Module
FLK-A3002FC FC Wireless AC/DC Current Module
FLK-V3000FC FC Wireless AC Voltage Module
FLK-V3001FC FC Wireless DC Voltage Module
FLK-T3000FC FC Wireless K-Type Temperature Module
FLK-PC3000 FC Adapter and Software
Kits:
FLK-3000 FC Industrial Kit Fluke 3000 FC Industrial System includes
multimeter, three iFlex clamp modules, one ac voltage module and accessories
FLK-3000 FC General Maintenance Kit Fluke 3000 FC General Maintenance
System includes multimeter, iFlex clamp module, ac voltage module, dc voltage
module and accessories
FLK-3000 FC HVAC Kit Fluke 3000 FC HVAC System includes multimeter, ac
current clamp module, temperature module and accessories
FLK-T3000 FC Kit Fluke t3000 FC Kit includes multimeter, temperature module
and accessories
FLK-A3000 FC Kit Fluke a3000 FC Kit includes multimeter, ac current clamp
module and accessories
FLK-A3001 FC Kit Fluke a3001 FC Kit includes multimeter, iFlex clamp module
and accessories
FLK-V3000 FC Kit Fluke v3000 FC Kit includes multimeter, ac voltage module
and accessories
FLK-V3001 FC Kit Fluke v3001 FC Kit includes multimeter, dc voltage module
and accessories
FLK-V3003 FC Kit Fluke v3003 FC Kit includes multimeter, ac voltage module,
dc voltage module and accessories