V15
2
INPUT SPECIFICATIONS:
Voltage …...………........….................................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….………….................... 120A max. @240Vac
Conducted EMI ………………………….………………CISPR/FCC Class B
Leakage Current …………………………………………….…… 3.5mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit Protection ………………………….……………… Continuous
Over Voltage Protection ……………...........................................….....… Yes
GENERAL SPECIFICATIONS:
Isolation ………………………………………… Input to output = 4,242VDC
Operating Temperature ………….. 0 ~ 65℃,40~65℃ with 2%/℃ Derating
Storage Temperature ……………………………...….......….... -20~85℃
Cooling …………………………………..……………….. Natural Convection
Switching Frequency …………………………………………… 67KHz Typical
Dimensions ……..…. 7.087x2.913x1.614 inches (180.00x74.00x41.00 mm)
1. Voltage setpoint at 60% full load
Weight ……………………………………………………… 950g(2.1Pounds)
2. Add a 0.1uF ceramic capacitor and a 47uF E.L. capacitor to output for
AC Inlet ……………….…………………………………...……… IEC320/C14
Ripple & Noise measurement @20MHz BW.
SAFETY AND EMC:
3. Line regulation measured from 100Vac to 240Vac with full load.
Emission and lmmunity ……… EN55022 Class B, FCC Part 15 Class B
4. Load regulation measured from 60% to 100% full load and from 60% to
EN61000-3-2,EN61000-3-3, EN55024
20% full load (60% +/- 40% full load)
EN61204-3
5. ”Various TRG Series adapters are PSE certified. PSE certification
Safety ………………………...IEC60950-1, EN60950-1, UL60950-1
alone is not sufficient for importation into Japan. A valid PSE mark
must contain the name of the importer as shown in the example below.
If PSE mark is required, the name of the registered importer must be
supplied to Cincon on order placement. Product labels will not contain
PSE mark if importer name is not supplied. Consult factory or local
representative for details”
Mechanical Specification
UNIT:inches(mm)
IEC320/C14
DC Plug :Right Angle(ψ5.5/ψ2.5) L12mm
DC Plug type: V+ ─●)─ V-
16AWG/1800mm
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
Typical at 25˚C, nominal line and 60% load, unless otherwise Specified