Pr oduct Catalog
SENSING AND CONTROL
Switches and Custom Controls
!
WARNING
MISUSE OF DOCUMENTATION
The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
!
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
!
WARNING
IMPROPER INSTALLAION
Consult with local safety agencies and their requirements
when designing a machine-control link, interface and all
control elements that affect safety.
Strictly adhere to all installation instructions.
Failure to comply with these instructions could result in
death or serious injury.
1
www.honeywell.com/sensing
Introduction - How to use this catalogue .....................................................Page 2
Industrial Electromechanical Limit Switches ................................................ Page 5
Selection Guide .............................................................. Page 6
Limit Switch Application Information .................................... Page 8
Global Limit Switches .................................................... Page 10
Compact Limit Switches ................................................. Page 21
Precision Limit Switches ................................................. Page 34
Heavy Duty Limit Switches ............................................... Page 46
Hazardous Location Switches ........................................... Page 57
Levers for Limit Switches ................................................ Page 71
Power Relays .................................................................................... Page 74
Electromechanical Safety Switches.......................................................... Page 79
Selection Guide ............................................................ Page 80
Basic Switches ................................................................................. Page 103
Pressure Switches ............................................................................. Page 113
Environment Sealed, Hermetically Sealed and Manual Switches .................... Page 119
Sealed Switches .......................................................... Page 119
Manual Switches ......................................................... Page 139
Manual Switches and Pushbuttons ........................................................ Page 165
Selection Guide ........................................................... Page 166
AML Series Advanced Manual Line Switches ........................ Page 168
MML Series Miniature Manual LIne Switches ....................... Page 171
Custom Switches and Assemblies .......................................................... Page 173
Vehicle Controls ............................................................................... Page 175
Custom Controls ........................................................... Page 175
Hour Meters ................................................................ Page 176
Key Switches .............................................................. Page 184
Push/Pull Switches ....................................................... Page 185
Shifters ..................................................................... Page 186
Proportional Retarders................................................... Page 187
Turn Signals ............................................................... Page 188
Lighting Products ......................................................... Page 189
Other Vehicle Controls ................................................... Page 194
Precision Aerospace .......................................................................... Page 195
Sensing and Control Product Overview .................................................... Page 196
New Technologies and Emerging Capabilities........................................... Page 198
Index ............................................................................................ Page 199
Sales and Service ............................................................................. Page 210
CONTENTS
2www.honeywell.com/sensing
INTRODUCTION
HONEYWELL SWITCHES AND CONTROLS
Honeywell switches and controls provide a wide selection of solutions.
This catalogue contains our most popular offerings. To view our
complete range of products, visit our web site at
http://www.honeywell.com/sensing.
Honeywell is a worldwide leader in advanced switching and sensing
technology. Our reputation for technology, quality and reliability is
second to none. We have more than 60 years of experience; and
extensive knowledge of a wide range of industries and an extensive
customer service and support network.
Honeywell manufactures the original MICRO SWITCH brand switches:
micro switches, toggle and rocker switches, hermetically and
environmentally sealed switches, and relays and limit switches. Honeywell
switches are aimed at providing an enhanced level of performance and
quality.
Honeywell HOBBS brand is well known worldwide for the development of
quality electromechanical products. The HOBBS brand includes hour
meters and battery discharge indicators, key switches, off-highway
vehicular lighting, shifters, pressure and vacuum switches, and custom
product development and rapid prototyping technology.
Honeywell’s aerospace switches and controls are designed for the most
stringent industry requirements. The portfolio consists of position, force,
torque and pressure sensors, indicators and actuators. In addition to
our standard product offering, Honeywell offers repair and overall
services for highly engineered aerospace controls.
Honeywell continues to strive to solve customers’ needs. Whether you
need custom solutions or standard off-the-shelf products, our extensive
in-house design, manufacturing and environmental testing capabilities
offer solutions and alternatives to meet your needs.
3
www.honeywell.com/sensing
INTRODUCTION
How to use this catalogue
For each referenced listing, key specification parameters, descriptions
and mounting drawing information are presented. These illustrate our
capabilities while the specifications allow easy differentiation between
similar products.
There are, of course, many more product options available. Full product
specification may be accessed on our website (www.honeywell.com/
sensing). At the Home page enter the catalog listing in the SEARCH box
and click GO! This will take you directly to the interactive catalogue/
specification search tables for this listing. Alternatively select and click the
interactive catalogue icon on the Home page and then choose a product
category against which to do a specification search.
Also on the website you can access installation instructions, application
notes, Frequently Asked Questions (FAQs), selection guides and
additional technical information.
Mounting dimensions
Mounting dimensions shown in each product section are for reference
only. For exact information, request an engineering drawing from your
nearest Honeywell sales office or visit our website and access it through
the interactive catalogue. Where dual dimensions are shown on
mounting drawings, the first or upper one is millimetres (mm) and the
second or lower is inches (in). Where single dimensions are shown,
they are millimetres (mm), unless otherwise stated.
To order these products
Simply contact your local Honeywell Sales Representative, your
Honeywell Distributor or your local Honeywell office.
If you need a product not listed in this catalogue
One of Honeywell’s strengths is in packaging of sensing technology to
meet customer needs. Honeywell provides many variations of our basic
switches and sensors. For more information, either browse the full
interactive catalogue available on our website, or telephone the following
numbers:
USA 1-800-537-6945/1-815-537-6945
UK +44 (0)1698 481 481 Germany +49 69 8064 444
France +33 1 60 19 80 40 Italy +39 02 92146 450/456
More information on Honeywell Sensing & Control products and how to
contact us can be found on our website.
Select the right product – select the right supplier
Delivering excellence in system critical sensing
solutions
A system is critical if the quality, reliability, delivery and customer service
associated with a component part is essential to the performance of the
operation or end product. If a sensor or a switch is critical to the
performance, cost effectiveness, delivery or safety of a product or
operation then it’s system critical. It is therefore a defining element in the
performance of the system under whatever conditions apply. Failure of
the component - or failure of delivery of the component - results in lost
productivity, increased costs or a catastrophic event such as a
shutdown. Therefore selecting the right product is essential. It can
make the difference between success and failure.
Honeywell Sensing and Control – delivering excellence
To select the right product, first select the right supplier. To deliver the right
products for our customers’ needs we listen to them to understand their
needs. Using techniques such as “Voice of the Customer and “Concept
Engineering” we make sure that the products and solutions we deliver are the
right ones. As part of Honeywell we can use local knowledge and
understanding combined with global expertise and resources to achieve this.
We can deploy many key technologies to bring innovative solutions to
customers’ problems.
Our products are manufactured to work well and to last. We use Six Sigma
Plus productivity to ensure this is the case. We have award winning
manufacturing facilities around the world and recognised world class
business excellence in manufacturing and supply chain management to
deliver on time, anywhere in the world.
Our e-business approach offers instant access to product information,
technical support and application knowledge through out Internet site.
Check out our powerful interactive catalogue that can search and find the
right products for customers’ needs and deliver a drawing ready for
incorporation in a CAD system direct to your desk.
And of course, we manage our whole business for the benefit of our
customers, using an acknowledged world-class business excellence
approach that incorporates Six Sigma principles.
Expanded Product Lines
As well as many new and innovative switches, this catalogue includes an
expanded range of Pressure and Position Sensors, previously known
under the Clarostat, NEI and Electrocorporation brand names.
4www.honeywell.com/sensing
5
www.honeywell.com/sensing
Industrial Electromechanical
Limit Switches
Honeywell offers an advanced line of heavy duty limit switches and a wide
selection of application-proven enclosed switches (precision snap-acting
switches sealed in rugged metal housing). Sealed versions keep out
moisture and other contaminants. Our products meet or exceed critical
standards allowing for global use. Our rugged switches are suitable for use
in harsh-duty, wash-down environments. We offer a variety of circuitry,
terminations and actuators to ensure that you can match your choice of
switch to your application.
Limit and enclosed switches are the cost effective switches of choice for
detecting objects which can be touched. When an object comes in contact
with an actuator, the switch operates. Rugged and dependable, these
switches are offered in a variety of sizes, with different seals, enclosures,
actuation, circuitries and electrical ratings. Enclosed switches are known
for enhanced precision and low cost. Limit Switches are especially
rugged and well sealed. Explosion proof switches are designed for use
in hazardous locations.
The Honeywell switches featured here are all proven in a broad range of
potential Industrial applications - machine tools, packaging machinery,
lifting gear, presses and construction machinery.
More information about our complete product range - and the depth of
product available within each product line - can be found on our interactive
catalogue at www.honeywell.com/sensing.
MICRO SWITCH Brand products
Honeywell has been at the forefront of switching technology since we were
the first to develop the precision snap-action switch more than 60 years ago.
Ever since we introduced the Micro Switch Brand Products in 1937, we have
been recognized as the performance standard that all other switches are
measured against. We continue in that tradition by constantly improving the
technology, cost-effectiveness, and delivery of these hardworking, versatile
electromechanical switches.
LIMIT SWITCHES
!
WARNING
IF USED IN APPLICATIONS CONCERNING HUMAN SAFETY
Only use NC direct opening (“positive opening”/ “positive
break”) contacts, identified by the symbol .
Do NOT use flexible / adjustable actuators. Only use
actuators designed for safety applications.
Do NOT defeat, tamper, remove, or bypass this switch.
Hazardous voltage, disconnect power before servicing.
Strictly adhere to all installation and maintenance
instructions.
Consult with local safety agencies and their requirements
when designing a machine-control link, interface and all
control elements that affect safety.
Failure to comply with these instructions could result in
death or serious injury.
6www.honeywell.com/sensing
Selection Guide
for Limit Switches
EVN2000
EX
GXE
CX
BF
14CE100
LSX/BX
SZL-VL
GLA
GLA GLE
GLC GLD
LIMIT SWITCHES
GLOBAL
PRECISION
HAZARDOUS LOCATION
Dimensions
EVN2000
DC13, Q300
SZL-VL
64 96,0 x 28,0 x 39,0
[3.8 x 1.10 x 1.51] 5 A Resistive -
125, 250 Vac 0.4 A Resistive
125 Vdc
EN50041
(GLA)
1, 4, 12, 13 102,9 x 42,0 x 42,0
[4.05 x 1.65 x 1.65] AC15 A600
(A300 DPDT) DC13
EN50047
(GLC/D/E)
66
GLC/E
1, 4, 12, 13
GLD
1, 2, 12
77,0 x 30,0 x 30,5
[3.03 x 1.18 x 1.20]
AC15 A600
Plastic,
A300 Metal
Housing
DC13
SL1
67 28.4 x 44.2 x 18,0
[1.12 x 1.74 x 0.71]
14CE914CE24CE924CELS
(-L)
67
(20 mm
conduit)
1, 3, 4, 6, 13
(½ in conduit) 94,0 x 40,6 x 58,42
[3.7 x 1.6 x 2.3]
BF
67 44,5 x 73,5 x 30,2
[1.75 x 2.9 x 1.19]
BZE/DTE
1 (E6)
1, 3 (V6) 44,4 x 77,2 x 25,4
[1.75 x 3.04 x 1.0]
E7
50 (standard),
65 (boot seal) 45,2 x 76,4 x 25,4
[1.67 x 3.0 x 1.0]
BAF/DTF
1, 3, 4, 13;
1 (-2RQ9) 54,8 x 101,6 x 33,0
[2.16 x 4.0 x 1.3]
HDLS
1, 3, 4, 4X, 6, 6P,
12, 13
HDLS
Fully potted
1, 4, 6, 6P, 12, 13
(connector)
1, 4, 6, 6P, 12
(cable)
HDLS
Stainless
steel
Stainless
Steel 1, 3, 3R, 4, 4X, 6,
6P, 12, 13 123,0 x 47,7 x 61,9
[4.9 x 1.9 x 2.4]
14CE100
65 (standard),
67 (boot seal)
1, 3 (standard),
1, 3, 4, 12, 13
(boot seal)
49,0 x 40,0 x 16.0
[1.93 x 1.57 x 0.63]
GXE
66/67 60,0 x 52,0 x 25,0
[2,36 x 2.05 x 1.0]
EX
1, 7, 9 65,0 x 93,0 x 52,0
[2.56 x 3.66 x 2.0]
CX
1, 3, 4, 4X, 6, 6P,
7, 9, 13 102,0 x 102,0 x 145,0
[4.0 x 4.0 x 5.71]
LSX
1, 3, 4, 6, 7, 9, 13
BX
67
Precision
1, 2, 3, 3R, 4, 6,
6P, 12 (boot
seal), 13
10 A - 125 Vac,
20 A - 125 Vac
IEC
IP AC
CE
C-UL
UL
CSA
Thermoplastic/
Metal
Series
Global
Plastic
CompactHeavy DutyHazardous Location
Approvals
66, 67, 68
Sealing
NEMA
(USA)
GL
Housing Material
Die cast base/
Plastic cover
66 (standard),
67 (boot seal)
Electrical Rating
5 A - 125, 250 Vac
5 A - 125, 250 Vac
10 A - 250 Vac
Height x Width x Depth
mm
[in]
Up to 20 A @
125, 250 or 480 Vac
121,0 x 76,0 x 73,0
[[4.8 x 3.0 x 3.0]
SDPT:
106,7 x 41,1 x 62,0
[4.2 x 1.6 x 2.4]
DPDT:
119,1 x 47,8 x 62,0
[4.7 x 1.9 x 2.4]
44,0 x 40,0 x 16,0
[1.73 x 1.57 x 0.63]
49,0 x 40,0 x 16,0
[1.93 x 1.57 x 0.63]
SPDT (NEMA A600),
DPDT (NEMA B600)
10 A Thermal:
SPDT (NEMA A600),
DPDT (NEMA B600)
10 A - 120, 240, 480 Vac
11 A - 125 Vac,
5 A - 125 Vac
1 A - 125 Vac,
15 A - 125 Vac
1 A - 125 Vac,
15 A - 125 Vac
AC14 D300,
DC13 R300
AC15,
DC13
Up to 20 A @
125, 250 or 480 Vac
Metal
1, 12, 1366, 67
DC
AC15, A300
67
3, 4, 13
(-L)
1, 3, 4, 13
1, 3, 4, 6, 7, 9, 13
CCC
GLL
65 1, 12, 13 10 A Thermal,
300 Vac 10 A Thermal,
250 Vdc
62,0 x 30,5 x 31,0
[2.44 x 1.20 x 1.22]
95,3 x 28,7 x 22,0
[3.75 x 1.13 x 0.87]
BZE/
DTE
E7
BAF/
DTF
7
www.honeywell.com/sensing
HDLS
LS
SL1
24/924CE
14/914CE
LIMIT SWITCHES
HEAVY DUTY
COMPACT
Stainless
Steel
HDLS
Termination
Make
Before
Break
1NC/
1NO 2NC/
2NO 1NC/
1NO 2NC/
2NO 1NC 1NC/
1NO 1NC/
1NO 2NC/
1NO 2NC/
2NO 3NC/
1NO 4NC
-25
[-13] 85
[185] Cable gland/
cord grip Insulation Displacement
Termination 10
-20
[-4] 60
[140] Flexible cable
gland/cord grip Gold plated silver
contacts standard 11
-25
[-13] 85
[185] 14
-40 85
[185] 16
-10
[-14] 70
[160] Cord grip
70
[221]
105
[221]
-29
[-20] 71
[160] Conduit
-32
[-25] 71
[160] Conduit
-32
[-25] 71
[160] Conduit Precise operation.
Low temperature
versions available 36
-30
[-22] 70
[158] Conduit
-32
[-25] 71
[160] Conduit Rugged housed precise
operation 42
-12 [-10];
-40 [-40] 121
[250]** Conduit
Low temperature and
Fluorocarbon Seal
versions available.
Wide variety of actuator
styles.
Cable and connector
available.
46
-12
[-10]
Connector
121 [250];
Cable
version
105 [221]
Cable or
Connector Switch cavity is epoxy
filled 53
-12 [-10]
-40 [-40] 121
[250]** Conduit, Cable Corrosion resistant
stainless steel housing 55
0
[32] 70
[158] Preleaded
cable Miniature size
-20
[-4] 75
[167] Preleaded
cable 59
-40
[-40] 71
[160] Conduit High temperature option
(400 °F for 100 Hr) 60
See Catalog
for details 85
[185] Conduit O
p
tional 4-20 mA
analog output 64
See Catalog
for details See Catalog
for details Conduit Wide variety of
actuators, circuitry and
termination options 66
-40
[-40] See Catalog
for details Conduit ATEX approvals for
European use 66
*HDLS, LSX and BX Series are available with the following Switching Options: NC/NO snap-action, Maintained;
additional data 2NC/2NO snap-action, Maintained; 2NC/2NO snap-action, Center Neutral; 2NC/2NO snap-action, Sequential
CX, LSX, BX also available with 1NC Direct Acting
Cable,
Quick Connect
0
[32];
low temp
option to
-30°
70
[221]
0
[32]
Page Number
Gold
Contacts
(Low
Energy
Options)
Low and high
temperature options
available.
Direct acting contacts
Low and high
temperature options
available.
Superior Sealing (IP 68)
Wide variety of actuator
styles and circuitry
options
°C
[°F]
From
Switching Options*
Cable,
Quick Connect
Break Before Make
Slow Action
Snap Action
Operating Temperature
23
26
Conduit
**Refer to catalog for
21
29
34
41
58
[-40]
To
Special Features
Cost effective solution
Precise operation
Miniature size
-10
[14] 80
[176]
2NC
Conduit Lowest cost
switch option 20
8www.honeywell.com/sensing
LIMIT SWITCHES
Proper application of limit switches
The following are guidelines for the correct application of Limit Switches.
Never use the Limit Switch as a physical end stop. Mechanical damage or
incorrect operation may occur if this is done. Always ensure that the
mechanical actuator is protected from excessive mechanical shock. Never
release the actuator suddenly - gradual actuation and release will ensure that
stress on the mechanics of the switch is kept to a minimum. This has the
added benefit that the switch life will be improved. The diagrams illustrate
how to actuate your limit switch for optimum performance.
Standards and Electrical rating
IEC/EN 60947-1 explains the general rules relating to Low Voltage
switchgear and controlgear. The purpose of this standard is to
harmonize as much as possible the product performance and test
requirements for equipment where the rated voltage does not exceed
1,000 Vac or 1,500 Vdc.
IEC 60947-5-1 is part 5 of the general rules which relates to Control-
circuit devices and switching elements, where rated voltage does not
exceed 1,000 Vac or 600 Vdc. There are special requirements for control
switches with direct opening operation. These switches are marked on
the outside with this symbol:
The Contact Element form defines the configuration and number of
contacts within the switch.
Form Za – both contact elements have the same polarity
Form Zb – the two contact elements are electrically separated.
The Utilization Category defines the type of current carried – ac or dc –
and the typical application where the switch is used.
The contact rating Designation relates to the Utilization Categories and
defines the conventional thermal current Ith (a) rated operational current Ie
(A) at rated operational voltages Ue and the VA rating.
Actuators
A range of actuators is available for limit switches. Illustrations of actuator
types available from this catalogue are shown at the beginning of each
product family. Other actuators may be available - for more information
please contact your local Honeywell office.
For limit switches with pushrod actuators, the actuating force should be applied as
nearly as possible in line with the pushrod axis.
Cam or dog arrangements should be such that the actuator is not suddently released
to snap back freely.
Operating mechanisms for limit switches shoud be so designed that, under any
operating or emergency conditions, the limit switch is not operated beyond its
overtravel limit position. A limit switch should not be used as a mechanical stop.
For limit switches with lever actuators, the actuating force should be applied as
nearly perpendicular to the lever as practical and perpendicular to the shaft axis
about which the lever rotates.
WRONG WRONG
RIGHT FIXED STOP
RIGHT
WRONG WRONG
RIGHT RIGHT
over-riding
cam
over-riding
cam
WRONG WRONG
RIGHT RIGHT
free position
free position
interference
end of
overtravel
operated
position
end of
overtravel
WRONG
RIGHT
over-riding
non-over-riding
Roller lever Top roller
lever Adjustable
roller lever Top pin
plunger
Top pin
plunger,
boot seal
Top roller
plunger
Top roller
plunger,
boot seal
Top roller
plunger,
perpendicular
Top roller
plunger,
perpendicular,
boot seal Ball bearing
plunger
Side
roller plunger
Side
pin plunger Roller lever Yoke lever Rod lever Wobble head
9
www.honeywell.com/sensing
LIMIT SWITCHES
A Note on Degrees of Protection
IP Classification
The IEC 529 standard describes a system for classifying the degree of
protection provided by the enclosures of electrical equipment. The level of
protection given by the enclosure is indicated by the IP code. This code
system uses the letters ‘‘IP’’ (International Protection) followed by up to four
digits. Normally only the first two digits are used.
IP 1st Digit 2nd Digit 3rd Digit 4th Digit
The first digit is numerical and indicates the level of protection within the
enclosure against the ingress of solid foreign objects and access to
hazardous parts by persons.
The second digit is also numerical and indicates the level of protection
against the ingress of WATER into the enclosure.
The third digit is a letter and indicates a higher level of protection for
persons against access to hazardous parts.
The fourth digit is also a letter and is used in exceptional cases for
supplementary information.
If the first or second digit is not required to be specified, then it is replaced
by the letter ‘‘X’’ (‘‘XX’’ if both digits are not required). While the tables
below serve as a guide to the level of protection, Honeywell recommends
that customers refer to the full official IEC specification for the exact
definitions. If in doubt about the degree of protection required for a particular
application, please consult your local Honeywell office.
Note:
The IEC 529 standard does not relate to protection against rust, corrosion,
icing or corrosive solvents (e.g. cutting fluids) and that product coded IP 67
may not necessarily meet IP 66 requirements.
First Digit Protection against ingress of solid objects
IP TEST
0 no protection
1 protected against solid objects with a diameter greater than 50 mm
2 protected against solid objects with a diameter greater than 12 mm
3 protected against solid objects with a diameter greater than 2.5 mm
4 protected against solid objects with a diameter greater than 1 mm
5 protected against dust-limited ingress (no harmful deposit)
6 totally protected against dust
Second Digit Protection against ingress of water
IP TEST
0 no protection
1 protected against vertically falling drops of water
2 protected against vertically falling drops of water when the enclosure is
tilted at an angle up to 15 degrees
3 protected against water sprayed at an angle of 60 degrees from the vertical
4 protected against splashing water from all directions – limited ingress (no
harmful effects)
5 protected against low pressure jets of water from all directions – limited
ingress permitted
6 protected against powerful jets of water from all directions – limited
ingress permitted
7 protected against the effects of temporary immersion in water
8 protected against the effects of continuous immersion in water
NEMA Classification (USA)
NEMA (National Electrical Manufacturer’s Association) prepares standards
which define a product, process or procedure with reference to one or more
of the following: nomenclature, composition, construction, dimensions,
tolerances, safety, operating characteristics, performance, quality, electrical
rating, testing and the service for which designed. This standard provides
degrees of protection for Enclosures for Electrical Equipment (1000 Volts
Maximum) similar to that of the IEC 529 standard. The reference standard
herein reflects the latest data in the NEMA Standards Publication when this
information went to print. Please check the most current NEMA
Standards Publication for the latest information.
Non-hazardous locations
Type 1 enclosures are intended for indoor use primarily to provide a
degree of protection against contact with the enclosed equipment.
Type 3 enclosures are intended for outdoor use primarily to provide a
degree of protection against windblown dust, rain, sleet, and external ice
formation.
Type 4 enclosures are intended for indoor or outdoor use primarily to
provide a degree of protection against windblown dust and rain, splashing
water, and hose-directed water.
Type 4X enclosures are intended for indoor or outdoor use primarily to
provide a degree of protection against corrosion, windblown dust and rain,
splashing water, and hose-directed water.
Type 6 enclosures are intended for indoor or outdoor use primarily to
provide a degree of protection against the entry of water during occasional
temporary submersion at a limited depth.
Type 6P enclosures are intended for indoor or outdoor use primarily to
provide a degree of protection against the entry of water during prolonged
submersion at a limited depth.
Type 12 enclosures are intended for indoor use primarily to provide a degree
of protection against dust, falling dirt, and dripping noncorrosive liquids.
Type 13 enclosures are intended for indoor use primarily to provide a degree
of protection against dust, spraying water, oil and noncorrosive coolant.
Note:
Enclosures are based, in general, on the broad definitions outlined in NEMA
Standards. Therefore, it will be necessary to ascertain that a particular
enclosure will be adequate when exposed to the specific conditions that
might exist in intended applications.
Except as might otherwise be noted, all references to products relative to
NEMA enclosure type are based on Honeywell evaluation and Underwriter’s
Laboratory (UL) tested. This NEMA Standards Publication does test for
environmental conditions such as corrosion, rust, icing, oil, and coolants.
The IEC 529 does not, and does not specify degree of protection against
mechanical damage of equipment. For this reason, and because the tests and
evaluations for other characteristics are not identical, the IEC Enclosure
Classification Designations cannot be exactly equated with NEMA Enclosure
Type Numbers.
10 www.honeywell.com/sensing
GLOBAL LIMIT SWITCHES
EVN2000 Series
EN 50047
Global Limit
Switches
The EVN2000 series limit switch is an innovative product which has been developed to address a
need highlighted by Original Equipment Manufacturers (OEM), where “Ease of Wiring” is required.
With the new design there is no need for access to the inside of the housing and therefore the
housing cover, cover screws and gasket become obsolete. Furthermore, the integrated cable
gland eliminates the need for additional conduit or cable gland hardware. All Normally Closed (NC)
contacts are Direct Opening.
Mechanical life: 10 million
Sealing: IP 66/67, NEMA 1, 12, 13
Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
EN 60529
EN81-1
AC15 A300
DC13 Q300
UL, CE
Housing material: Plastic
Termination: Insulation Displacement Terminals (IDT)
Switching options: SPDT Single Pole, Double Throw,
Snap action contacts (1NC/1NO)
OPTIONS
Side rotary plastic roller
CAT. LISTING
EVN2000A
Top pin plunger
CAT. LISTING
EVN2000B
Top roller plunger, perpendicular
CAT. LISTING
EVN2000D
Operating characteristics
Actuator Operating Free Pretravel Travel to Overtravel Differential Operating
type torque/force position positive opening travel point
(OF) (FP) (PT) (PO) (OT) (DT) (OP)
Side
rotary 0,120 N m 0° 2 45° 45° 12° 25°
EVN2000A [1.10 lb in]
Top pin
plunger 16,0 N 20,0 mm 2,0 mm 3,5 mm 4,0 mm 1,0 mm 18,0 mm
EVN2000B [3.60 lb] [0.79 in] [0.08 in] [0.14 in] [0.16 in] [0.04 in] [0.71 in]
Top roller
plunger, 16,0 N 30,0 mm 2,0 mm 3,5 mm 4,0 mm 1,0 mm 28,0 mm
parallel [3.60 lb] [1.18 in] [0.08 in] [0.14 in] [0.16 in] [0.04 in] [1.10 in]
EVN2000C
Top roller
plunger, 16,0 N 30,0 mm 2,0 mm 3,5 mm 4,0 mm 1,0 mm 28,0 mm
perpendicular [3.60 lb] [1.18 in] [0.08 in] [0.14 in] [0.16 in] [0.04 in] [1.10 in]
EVN2000D
Actuators
Top roller plunger, parallel
CAT. LISTING
EVN2000C
11
www.honeywell.com/sensing
VL Series
General Purpose Compact
Limit Switches
The new economical SZL-VL Series miniature type limit switches are
specially designed for potential applications of small mounting space.
These miniature switches are ideal for OEM machinery which requires a
rugged and reliable limit switch that is capable of being mounted in space
restricted applications. A wide range of actuators and optional neon lamp
indicators add additional flexibility. A special pre-molded flexible cable
gland allows for fast and simple wiring termination.
Mechanical life: up to 10 million operations
Sealing: IP 64
Operating temperature: -20 °C to 60 °C [-4 °F to 140 °F]
Approvals: UL, C-UL, CE
Termination: Cable gland
Contacts: Gold plated silver
Electrical ratings: 250 Vac 125 Vdc max.
Ampere rating: 5 A @ 250 Vac max./0.4 A @ 125 Vdc max.
Switching options:
SPDT Single Pole, Double Throw, Double break
(1NC/1NO)
VL
34
21
NO
NC
NO
NC
Side rotary actuated switches
Pretravel max. (PT): 20°
Overtravel min. (OT): 75°
Differential travel max. (DT): 10°
OPTIONS
Roller lever
(Roller can be
in any position
(with hexagona l
7 .276 in depth
mounting holes
41.2±.08
36.2±0.8
nylon roller
R30
M4 arm
56±0.3
21±0.2
28
M3x6
cover scr ew
M4 arm fixing nut
12.5
.402
18.5
64
2-M5 (P=0.8)
tapped
14
7.5±0.2
15.1
38.1
25
2-M3x23
20.4±0.3
PT 20˚
max
cover scr ew
(Standard type)
18 dia.x7
through 360˚)
.827±.008
1.102
2.205±.012
.492
holes)
rotated and locked
1.622±.031
1.425±.031
10.2
.728
.803±.012
2.520
.551
1.5
.984
.594 .295±.008
mounting holes
2-M5 (P=0.8)
tapped
mounting holes
2-4.1 dia.
+0.2
-0
fixing screw
mounting holes
.161 dia.
+0.008
-0
Operating torque max.: 5,88 N [1.32 lb]
CAT. LISTING
SZL-VL-A
Roller lever, adjustable
hexagonal holes
Arm fastening plate
Mounting metal
M4 arm fastening
plate screw with
Adjustable length
of arm
(30-70)
.402
2.0
(Roller can be rotated
and locked in any
position through 360˚)
2-M3x23
cover screw
M3x6
cover screw
12.5
56±0.3
21±0.2
28
7 .276 in depth
mounting holes
2-M5 (P =0 .8) tapp e d
18.5
64
14
7.5±0.2
15.1 20.4±0.3
25
(46.4)
PT 20˚
max
(Standard type)
1.102
.827±.008
.492
2.205±.012
18 dia.x7 nylon rooler
hexagonal holes
plate screw with
M6 arm fastening
10.2
.728
2.520
.551
.295±.008
(1.827)
.984
.594 .803±.012
2-M5 (P =0 .8 ) tappe d
mounting holes
.079
mounting holes
2-4.1 dia.
+0.2
0
1.122±.031
1.319±.031
33.5±0.8
1.878±.031
47.7±0.8
42.7±0.8
1.681±.031
28.5±0.8
mounting holes
.161 dia.
+0.008
-0
Operating torque max.: 3,35 N to 7,84 N [0.75 lb to 1.76 lb]
CAT. LISTING
SZL-VL-B
GLOBAL LIMIT SWITCHES
Actuators
12 www.honeywell.com/sensing
VL Series
Side rotary actuated switches (continued)
Adjustable rod
7 .276 in dep th
mounting holes
hexagonal holes
.217 36.3±0.8
44.9
(Roller can be rotated
and locked in any
position through 360˚)
M4 rod fastening plate
screw with hexagonal holes
Rod fastening plate
12.5
56±0.3
21±0.2
28
Adjustable lenght of rod
(30-118)
.402
18.5
64
14
2-M5 (P=0.8) tapped
7.5±0.2
15.1 20.4±0.3
25
Rod mounting metal
M6 mounting rod
fastening screw with
2-M3x23
cover screw
M3x6
cover screw
(44.9)
PT 20˚
max
(Standard type)
5.5
2.6 .102 dia. rod
.492
2.205±.012
1.102
.827±.008
1.768
1.429±.031
10.2
.728
2.520
.551
.295±.008
(1.768)
.984
.594 .803±.012
2-M5 (P=0.8) tapped
mounting holes
mounting holes
2-4.1 dia.
+0.2
0
mounting holes
.161 dia.
+0.008
-0
Operating torque max.: 2 N to 7,84 N
[0.45 lb to 1.76 lb]
CAT. LISTING
SZL-VL-C
Plunger actuated switches
Pretravel max. (PT): 1,5 mm [0.060 in]
Overtravel min. (OT): 4,0 mm [0.158 in]
Differential travel max. (DT): 0,7 mm [0.028 in]
Operating force max. (OF): 8,83 N [2 lb]
Top pin plunger
mounting holes
.402
2-M3x23
cover screw
2-4.1 +0.2
mounting holes
2-M5 (P=0.8) tapped
7 .276 in depth
M3x6
cover screw
64
14
7.5±0.2
15.1
25
20.4±0.3
.118
26.5
56±0.3
21±0.2
28
stainless steel plunger
mounting hol e s
2-M5 (P=0.8) tapped
(Standard type)
7. 276 dia.
dia.
3
1.043
2.205±.012
1.102
.827±.008
10.2
.803±.012
4
2.520
.984
.594 .295±.008
.157
.551
0
PT 1.5 max
.161 +0.008
mounting holes
dia.
-0
CAT. LISTING
SZL-VL-D
Top roller plunger
56±0.3
38
14.8
12.5 dia.x3.8
stainless steel roller
21±0.2
28
2-M3x23
cover screw
M3x6
cover screw
.402
20.4±0.3
.157
64
14
7 .276 in dep th
mounting holes
2-M5 (P=0.8) tapped
mounting holes
2-M5 (P=0.8) tapped
15.1
25
7.5±0.2
(Standard type)
.583
1.496
2.205±.012
1.102
.827±.008
10.2
.803±.012
4
2.520
.551
.295±.008
.594
.984
mounting holes
2-4.1 dia.
+0.2
0
PT 1.5 max
mounting holes
.161 dia.
+0.008
-0
CAT. LISTING
SZL-VL-H
GLOBAL LIMIT SWITCHES
13
www.honeywell.com/sensing
Plunger actuated switches (continued)
Cross roller plunger
.402
M3x6
cover screw
12.5 dia.x3.8
stainless steel roller
2-M3x23
cover scre w
21±0.2
28
56±0.3
38
14.8
7.5±0.2
15.1
25
20.4±0.3
.157
64
14
mounting ho l es
2-M5 (P=0.8) tapped
7 .276 in depth
mounting ho l es
2-M5 (P=0.8) tapped
(Standard type)
.583
1.496
2.205±.012
.827±.008
1.102
10.2
4
.803±.012
2.520
.551
.295±.008
.984
.594
mounti ng ho l es
2-4.1 dia.
+0.2
0
PT 1.5 ma x
mounting holes
.161 -0 dia.
+0.008
CAT. LISTING
SZL-VL-E
Wobble actuated switches
Pretravel max. (PT): 30 mm [1.18 in]
Overtravel min. (OT): 20 mm [0.788 in]
Operating force max. (OF): 0,88 N [0.2 lb]
Plastic rod, coil spring
.402
21±0.2
56±0.3
14
64
7.5±0.2
.157
28
20.4±0.3
25
15.1
5.8 dia.
3 dia.
Nylon rod
41.5
100±1.5
2-M3x23
M3x6
cover sc rew 7 .276 in depth
mo un t ing holes
2-M5 (P=0.8) t apped
PT 50 max
(Standard type)
cover screw
1.634
3.937±.059
2.205±.012
1.102
.827±.008
10.2
.118
.228
.803±.012
4
2.520
.551
.295±.008
.984
.594
2-M5 (P=0.8) tap ped
mo un t ing holes
mounting hol es
2-4.1 dia.
+0.2
0
mounting hol es
.161 dia.
+0.008
-0
CAT. LISTING
SZL-VL-F
Coil spring
.402
21±0.2
56±0.3
14
64
7.5±0.2
.157
28
20.4±0.3
25
15.1
.047 stainless
51.5
100±1.5
2-M3x23
cover screw
M3x6
cover screw 7 .276 in depth
mounting holes
2-M5 (P=0
1.2 dia.
PT 30 max
(Standard type)
.8) tapped
2.028
3.937±.059
2.205±.012
.827±.008
1.102
10.2
steel wire
.803±.012
4
2.520
.551
.295±.008
.984
.594
2-M5 (P=0.8)
mounting holes
mounting holes
2-4.1
tapped
dia.
+0.2
0
SZL-VL-G
mounting holes
-0
.161 dia.
+0.008
CAT. LISTING
SZL-VL-G
GLOBAL LIMIT SWITCHES
14 www.honeywell.com/sensing
GLS Series
Global Limit
Switches
GLOBAL LIMIT SWITCHES
SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT
EN50041
(GLA)
EN50047
(GLC, GLD,
GLE)
0,120 N m
[1.10 lb in]
0,165 N m
[1.50 lb in]
GLE only 11.5°
EN50041
(GLA)
EN50047
(GLC, GLD,
GLE)
16,0 N
[3.60 lb]
13,0 N
[2.90 lb]
GLE only
0,9 mm
[0.035 in] 0,6 mm
[0.024 in]
EN50041
(GLA)
EN50047
(GLC, GLD,
GLE)
16,0 N
[3.60 lb]
13,0 N
[2.90 lb]
GLE only
0,9 mm
[0.035 in] 0,6 mm
[0.024 in]
EN50041
(GLA)
EN50047
(GLC, GLD,
GLE)
11,0 N
[2.4 lb]
9,0 N
[1.9 lb]
GLE only
EN50041
(GLA)
EN50047
(GLC, GLD,
GLE)
1,3 N
[0.29 lb]
1,1 N
[0.25 lb]
GLE only 10°
Actuator
type Body
size
26°
35,8 mm
[1.41 in]
61,0 mm
[2.40 in]
28,0 mm
[1.10 in]
48,0 mm
[1.89 in]
18,0 mm
[0.71 in]
35,0 mm
[1.38 in]
4,5 mm
[0.18 in]
__
__
59°
49°
0,9 mm
[0.035 in]
12°
0,9 mm
[0.035 in]
1,7 mm
[0.067 in]
1,3 mm
[0.19 in]
16°
18°
3,0 mm
[0.12 in]
3,0 mm
[0.12 in]
__
4,5 mm
[0.18 in]
9,0 mm
[0.35 in]
__
5,2 mm
[0.205 in]
2,5 mm
[0.10 in]
3,0 mm
[0.12 in]
4,2 mm
[0.165 in]
3,45 mm
[0.14 in]
Overtravel
(OT) Differential travel
(DT) Operating point
(OP)
Top roller
lever
D
Lever types
A,
A*A, A*B,
A4J
Top pin
plunger
B
Top roller
plunger
C
Operating torque/f orce
(OF) Pretravel
(PT)
0,330 N m
[2.90 lb in]
Wobble head
E7B, E7D,
K8B, K8C
16,0 N
[3.60 lb]
16,0 N
[3.60 lb]
9,5 N
[2.10 lb]
0,1 N
[0.90 in lb]
Free position
(FP)
Travel to
positive opening
(PO)
55°26°
37,5 mm
[1.48 in]
21,0 mm
[0.83 in]
4,5 mm
[0.18 in]
5,0 mm
[0.20 in]
2,5 mm
[0.10 in]
3,0 mm
[0.12 in]
50,5 mm
[2.00 in]
31,0 mm
[1.22 in]
65,2 mm
[2.57 in]
39,25 mm
[1.55 in]
__
__
4,5 mm
[0.18 in]
5,0 mm
[0.20 in]
8,3 mm
[0.33 in]
6,9 mm
[0.27 in]
Operating characteristics
IEC947-5-1/EN60947-5-1
Designation & Rated operational current Ie (A) VA
Utilization Category at rated operational voltage Ue rating
120V 240V 380V 480V 500V 600V Make Break
AC15 A600 6 3 1.9 1.5 1.4 1.2 7200 720
AC15 A300 6 3 - - - - 7200 720
AC15 B300 3 1.5 - - - - 3600 360
AC14 D300 0.6 0.3 - - - - 432 72
125V 250V
DC13 Q300 0.55 0.27 69 69
DC13 R300 0.22 0.1 28 28
Electrical ratings
GLS Series switches offer a complete range of CENELEC approved
products, and are suitable for most potential industrial applications.
The standard product EN 50041 norm defines the switch mounting
centres as 30 mm x 60 mm and also defines the switching
characteristics of the side rotary head with fixed lever, top pin plunger
and top roller plunger. This means that the switch can be interchanged
in the application with other EN 50041 switches with mounting and
switching characteristics maintained. Honeywell offers many more head
styles and switching options.
The miniature EN 50047 product range offers the user a choice of
plastic, metal and three conduit versions which are all mounting (20 mm
x 22 mm) compatible with each other. The EN 50047 standard defines
how the switches are mounted and the switching characteristics for fixed
side rotary lever, top pin plunger and top roller plunger.
Switching options:
SPDT Single Pole, Double Throw, Snap action contacts (1NC/1NO)
13 14
21 22
DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO)
13 14
12
11
23
21 24
22
Actuators
Vibration (Actuator not fitted): 10 g conforming to IEC 68-2-6
Shock (Actuator not fitted): 50 g conforming to IEC 68-2-27
Terminal marking to EN 50013
15
www.honeywell.com/sensing
GLA EN 50041
Standard metal body
Mechanical life: up to 15 million
Sealing: IP 67, NEMA 1, 4, 12, 13
Operating temperature: -25 °C to 85 °C
[-13 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
AC15 A300/A600
DC13 Q300
UL, CSA, CE
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
DPDT Double Pole, Double Throw
Snap action contacts (2NC/2NO)
HEAD OPTIONS
Side rotary
No lever
Levers: Levers for side rotary types are
ordered separately (see pages 71-73 for
details)
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01A
DPDT ½ in NPT GLAA20A
SPDT PG 13,5 GLAB01A
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01A1A
DPDT ½ in NPT GLAA20A1A
SPDT PG 13,5 GLAB01A1A
DPDT PG 13,5 GLAB20A1A
SPDT 20 mm GLAC01A1A
DPDT 20 mm GLAC20A1A
Metal roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01A1B
DPDT ½ in NPT GLAA20A1B
SPDT PG 13,5 GLAB01A1B
DPDT PG 13,5 GLAB20A1B
SPDT 20 mm GLAC01A1B
DPDT 20 mm GLAC20A1B
Side rotary adjustable roller
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01A2A
DPDT ½ in NPT GLAA20A2A
SPDT PG 13,5 GLAB01A2A
DPDT PG 13,5 GLAB20A2A
SPDT 20 mm GLAC01A2A
Metal roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01A2B
DPDT ½ in NPT GLAA20A2B
SPDT PG 13,5 GLAB01A2B
DPDT PG 13,5 GLAB20A2B
SPDT 20 mm GLAC01A2B
DPDT 20 mm GLAC20A2B
Side rotary adjustable metal rod
34
(1.34)
41
(1.61)
¯ 3,2
(.13)
75˚75˚
15
(.6)
32 - 134
(1.26 - 5,28)
4,5
(.17)
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01A4J
DPDT ½ in NPT GLAA20A4J
SPDT PG 13,5 GLAB01A4J
DPDT PG 13,5 GLAB20A4J
SPDT 20 mm GLAC01A4J
GLOBAL LIMIT SWITCHES
Top pin plunger
37,5
(1.48)
FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01B
DPDT ½ in NPT GLAA20B
SPDT PG 13,5 GLAB01B
DPDT PG 13,5 GLAB20B
SPDT 20 mm GLAC01B
DPDT 20 mm GLAC20B
Top roller plunger
FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01C
DPDT ½ in NPT GLAA20C
SPDT PG 13,5 GLAB01C
DPDT PG 13,5 GLAB20C
SPDT 20 mm GLAC01C
DPDT 20 mm GLAC20C
Top roller lever
35,0
(1.38)
65,2
(2.51)
Ø 18,7
(.74)
13,0
(.51)
FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01D
DPDT ½ in NPT GLAA20D
SPDT PG 13,5 GLAB01D
DPDT PG 13,5 GLAB20D
SPDT 20 mm GLAC01D
DPDT 20 mm GLAC20D
16 www.honeywell.com/sensing
GLA EN 50041
Standard metal body
(continued)
Wobble, coil actuator
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01E7B
SPDT PG 13,5 GLAB01E7B
DPDT PG 13,5 GLAB20E7B
SPDT 20 mm GLAC01E7B
DPDT 20 mm GLAC20E7B
Coil wobble head, stainless steel
spring actuator
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01E7D
Wobble, cat whisker
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01K8B
SPDT PG 13,5 GLAB01K8B
Wobble, cat whisker, coil
actuator
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLAA01K8C
DPDT ½ in NPT GLAA20K8C
SPDT PG 13,5 GLAB01K8C
GLC EN 50047
Standard metal body
24,75
(0.97)
14,5
(.57)
30
(1.18)
conduit thread
PG 13,5
22
(.87)
20
(.78)
3
(.12)
2,15
(.08)
R55
(2.16)
30,5
(1.20) 3,5
(0.138)
15,25
(.600)
Mechanical life: up to 10 million
Sealing: IP 66, NEMA 1, 4, 12, 13
Operating temperature*: -40 °C to 85 °C
[-40 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
AC15 A300
DC13 Q300
UL, CSA, CE
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
*Wobble actuator rated to -25 °C [-13 °F]
HEAD OPTIONS
Side rotary
°
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01A1A
SPDT PG 13,5 GLCB01A1A
Metal roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01A1B
SPDT PG 13,5 GLCB01A1B
SPDT 20 mm GLCC01A1B
GLOBAL LIMIT SWITCHES
17
www.honeywell.com/sensing
GLC EN 50047
Standard metal body
(continued)
Side rotary adjustable
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01A2A
SPDT PG 13,5 GLCB01A2A
Metal roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01A2B
SPDT PG 13,5 GLCB01A2B
SPDT 20 mm GLCC01A2B
Side rotary adjustable, metal rod
34
(1.34)
41
(1.61)
¯ 3,2
(.13)
75˚75˚
15
(.6)
32 - 134
(1.26 - 5,28)
4,5
(.17)
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01A4J
SPDT PG 13,5 GLCB01A4J
Top pin plunger
OP
DT
18±0,5
(.709)
Ø 9.9
(.390)
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01B
SPDT PG 13,5 GLCB01B
SPDT 20 mm GLCC01B
Top roller plunger
31,0
1.22 FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01C
SPDT PG 13,5 GLCB01C
SPDT 20 mm GLCC01C
Top roller lever
Ø
39,2
(1.54)
FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01D
SPDT PG 13,5 GLCB01D
SPDT 20 mm GLCC01D
Wobble, coil actuator
Mechanical life: up to 5 million
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01E7B
SPDT PG 13.5 GLCB01E7B
SPDT 20 mm GLCC01E7B
Wobble, cat whisker
Mechanical life: 5 million
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLCA01K8A
SPDT PG 13,5 GLCB01K8A
GLOBAL LIMIT SWITCHES
18 www.honeywell.com/sensing
GLD EN 50047
Double insulated plastic
standard body
24,75
(0.97)
14,5
(.57)
30
(1.18)
conduit thread
PG 13,5
22
(.87)
20
(.78)
3
(.12)
2,15
(.08)
R55
(2.16)
30,5
(1.20) 3,5
(0.138)
15,25
(.600)
Mechanical life: See GLC section
Sealing: IP 66, NEMA 1, 2, 13
Operating temperature*: -40 °C to 85 °C
[-40 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
AC15 A600
DC13 Q300
UL, CSA, CE
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
*Wobble actuator rated to -25 °C [-13 °F]
HEAD OPTIONS
See GLC section for dimension
illustrations
Side rotary
Plastic roller/lever
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01A1A
SPDT PG 13,5 GLDB01A1A
Metal roller/lever
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01A1B
SPDT PG 13,5 GLDB01A1B
SPDT 20 mm GLDC01A1B
Side rotary adjustable
Plastic roller/metal lever
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01A2A
SPDT PG 13.5 GLDB01A2A
Metal roller/metal lever
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01A2B
SPDT PG 13,5 GLDB01A2B
SPDT 20 mm GLDC01A2B
Side rotary adjustable metal rod
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01A4J
SPDT PG 13,5 GLDB01A4J
Top pin plunger
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01B
SPDT PG 13,5 GLDB01B
SPDT 20 mm GLDC01B
Top roller plunger
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01C
SPDT PG 13,5 GLDB01C
SPDT 20 mm GLDC01C
Top roller lever
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01D
SPDT PG 13,5 GLDB01D
SPDT 20 mm GLDC01D
Wobble, coil actuator
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLDA01E7B
SPDT PG 13,5 GLDB01E7B
SPDT 20 mm GLDC01E7B
GLE EN 50047 Compatible
3 conduit
metal standard body
Mechanical life: up to 10 million
Sealing: IP 66, NEMA 1, 4, 12, 13
Operating temperature*: -40 °C to 85 °C
[-40 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
AC15 A300
DC13 Q300
UL, CSA, CE
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
DPDT Double Pole, Double Throw
Snap action contacts (2NC/2NO)
*Wobble actuator rated to -25 °C [-13 °F]
HEAD OPTIONS
Side rotary
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01A1A
SPDT PG 13,5 GLEB01A1A
DPDT PG 13,5 GLEB24A1A
Metal roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01A1B
DPDT ½ in NPT GLEA24A1B
SPDT PG 13,5 GLEB01A1B
DPDT PG 13,5 GLEB24A1B
SPDT 20 mm GLEC01A1B
GLOBAL LIMIT SWITCHES
19
www.honeywell.com/sensing
GLE EN 50047 Compatible
3 conduit
metal standard body
(continued)
Offset side rotary roller
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01A5A
SPDT PG 13,5 GLEB01A5A
Side rotary adjustable
Plastic roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01A2A
DPDT ½ in NPT GLEA24A2A
SPDT PG 13,5 GLEB01A2A
Metal roller
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01A2B
SPDT PG 13,5 GLEB01A2B
DPDT PG 13,5 GLEB24A2B
GLOBAL LIMIT SWITCHES
Side rotary adjustable metal rod
34
(1.34)
41
(1.61)
¯ 3,2
(.13)
75˚75˚
15
(.6)
32 - 134
(1.26 - 5,28)
4,5
(.17)
CONTACT CONDUIT CAT. LISTING
SPDT PG 13,5 GLEB01A4J
DPDT PG 13,5 GLEB24A4J
Top pin plunger
18
(0.709)
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01B
DPDT ½ in NPT GLEA24B
SPDT PG 13,5 GLEB01B
DPDT PG 13,5 GLEB24B
Top roller plunger
31,0
1.23
Ø 12,4
(0.49)
FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01C
DPDT ½ in NPT GLEA24C
SPDT PG 13,5 GLEB01C
DPDT PG 13,5 GLEB24C
DPDT 20 mm GLEC24C
Top roller lever
39,2
(1.54)
FP
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01D
DPDT ½ in NPT GLEA24D
SPDT PG 13,5 GLEB01D
DPDT 13,5 GLEB24D
SPDT 20 mm GLEC01D
DPDT 20 mm GLEC24D
Wobble, coil actuator
OT
35˚ (max)
DT
10˚
16˚ ±5˚
(2.37) OP
100
(3.92)
Mechanical life: up to 5 million
CONTACT CONDUIT CAT. LISTING
SPDT ½ in NPT GLEA01E7B
DPDT ½ in NPT GLEA24E7B
SPDT PG 13,5 GLEB01E7B
DPDT PG 13,5 GLEB24E7B
20 www.honeywell.com/sensing
GLL EN50047
Standard plastic body
Mechanical life: 5 million
Sealing: IP 65, NEMA 1, 12, 13
Operating temperature: -10 °C to 80 °C
[14 °F to 176 °F]
Approvals: c-UL-US, CE, CCC
Switching options:
SPDT Single Pole, Double Throw
Direct opening snap action contacts
(1NC/1NO)
HEAD OPTIONS
Top plunger
CONDUIT CAT. LISTING
½ in NPT GLLA01B
20 mm GLLC01B
Top roller plunger
CONDUIT CAT. LISTING
½ in NPT GLLA01C
20 mm GLLC01C
Side rotary, 25 mm fixed length
with metal roller
CONDUIT CAT. LISTING
½ in NPT GLLA01A1B
20 mm GLLC01A1B
Side rotary, 20 mm to 65 mm
adjustable length lever with
metal roller
CONDUIT CAT. LISTING
½ in NPT GLLA01A2B
20 mm GLLC01A2B
Side rotary, 31,5 mm fixed length
lever with 50 mm rubber roller
CONDUIT CAT. LISTING
½ in NPT GLLA01A1Y
20 mm GLLC01A1Y
Side rotary, 20 mm to 65 mm
adjustable length lever with 50
mm rubber roller
CONDUIT CAT. LISTING
1/2 in NPT GLLA01A2Y
20 mm GLLC01A2Y
GLOBAL LIMIT SWITCHES
Actuators
21
www.honeywell.com/sensing
OPTIONS
Top pin plunger
25,4
(OP)
CONTACT CAT. LISTING
Silver SL1-H
Gold clad cross point SL1-HK
Top roller plunger, parallel
31,4
(OP)
CONTACT CAT. LISTING
Silver SL1-A
Gold clad cross point SL1-AK
SL1 Series
Compact Limit
Switches
The SL1 Series compact limit switches are sealed, sensitive and have a long life. The compact size makes them
suitable for the total miniaturization of machinery or equipment.
Mechanical life: 10 million
Sealing: IP 67, NEMA 3, 4, 13
Operating temperature: -10 °C to 70 °C [14 °F to 160 °F]
Approvals: UL, CSA, CE
Termination: Cable gland
Operating force max. (OF): 11,76 N [2.64 lb]
Pretravel max. (PT): 1,5 mm [0.060 in]
Overtravel min. (OT): 3,0 mm [0.118 in]
Differential travel max. (DT): 0,10 mm [0.004 in]
Electrical rating/contact: SL1-* 5A - 125, 250 Vac Silver
SL1-* K 0.1 A - 125 Vac; 0.1 A - 30 Vdc Gold clad cross point
Switching options:
SPDT Single Pole, Double Throw,
Snap action contacts (1NC/1NO)
Top roller plunger, parallel, boot seal
11 D X 4W ROLLER
PT
CONTACT CAT. LISTING
Silver SL1-B
Gold clad cross point SL1-BK
Top roller plunger, long, parallel
41,4
(OP)
CONTACT CAT. LISTING
Silver SL1-E
Gold clad cross point SL1-EK
COMPACT LIMIT SWITCHES
Actuators
22 www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
Top roller plunger, perpendicular
31,4
(OP)
CONTACT CAT. LISTING
Silver SL1-D
Gold clad cross point SL1-DK
Top roller plunger, long, perpendicular
41,4
(OP)
CONTACT CAT. LISTING
Silver SL1-K
Gold clad cross point SL1-KK
Top roller lever
Operating force max. (OF): 3,92 N [0.88 lb]
Pretravel max. (PT): 2,0 mm [0.079 in]
Overtravel min. (OT): 4,0 mm [0.158 in]
Differential travel max. (DT): 0,3 mm [0.012 in]
CONTACT CAT. LISTING
Silver SL1-P
Gold clad cross point SL1-PK
23
www.honeywell.com/sensing
14CE/914CE Series
Miniature Enclosed
Switches
The 14CE/914CE Series offers a miniature, rugged, compact, pre-wired switch which has gained
wide market acceptance and performed successfully in a wide range of potential applications. The
entire range of 14CE and 914CE switches has been approved to meet the requirements of the Low
Voltage directive and is therefore CE marked.
CE switches have different degrees of protection from IP66 to IP68 for the fully booted head styles.
The cable entry is fully potted using a special compound to ensure that ingress is virtually
impossible.
Mechanical life: 10 million
Sealing: IP66, IP67, IP68
NEMA 1, 2, 3, 3R, 4, 6, 6P, 12 (boot seal), 13
Operating temperature: 14CE 0 °C to 70 °C [32 °F to 158 °F]
914CE 0 °C to 105 °C [32 °F to 221 °F]
Approvals: 14CE CE
914CE CSA, UL, CE
AC14 D300
DC13 R300
Operating force (OF): 11,8 N [2,65 lb] max.
Pretravel (PT): 1,8 mm [0.71 in] max.
Overtravel (OT): 3,0 mm [0.118 in] min.
Differential travel (DT): 0,1mm [0.004 in] max.
Contact/Rating: (9)14CE* -* Silver A
(9)14CE* -*G Gold B
(9)14CE* -Q, -AQ, -AQ1 Silver C
Connection: Harmonised CENELEC 4 x 0,75 mm2 cable (14CE)
SJTO 4 x 0,75 mm2 (18 AWG) cable (914CE)
Connector (dc), 4 pin male, M12 thread (-Q)
Connector (ac), 4 pin male, ½ in x 20 thread (-Q1)
Switching options: SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
914CE 14CE
GREEN/YELLOW
BLUE
1
BROWN
2
3
BLACK
S.P.D.T
Electrical ratings: Amps
Make Break
A 240 Vac, ind. 1.2 0.2
240 Vac, res. 5 5
28 Vdc, res. 3 3
28 Vdc, ind. 3 3
UL/CSA: 5 A, 1/10 Hp, 125 or 250 Vac
B 1 A res., 0.5 A ind., 30 Vdc
UL: 1 A, 125 Vac
C UL/CSA: 3 A, 125 or 250 Vac
,
,
,
Operating
point
(OP)
Free position
(FP)
1,8 max PT 3 min OT
Side exit cable
(Option 'A')
14CE 7,4 (0.29)
914CE 8,65 (0.34)
Ø
Actuators
COMPACT LIMIT SWITCHES
24 www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
Plunger actuated switches
OPTIONS
Top pin plunger
Ø 10,0
(0.39) OP
15,7
(0.62)
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE1-3
3 ft cable, side exit 914CE1-3A
3 ft cable, bottom exit, gold contacts 914CE1-3G
6 ft cable, bottom exit 914CE1-6
6 ft cable, bottom exit, gold contacts 914CE1-6G
9 ft cable, bottom exit 914CE1-9
Connector (dc), bottom exit 914CE1-Q
Connector (ac), bottom exit 914CE1-Q1
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE1-1
1 metre cable, side exit 14CE1-1A
1 metre cable, bottom exit, gold contacts 14CE1-1G
2 metre cable, bottom exit 14CE1-2
3 metre cable, bottom exit 14CE1-3
3 metre cable, side exit 14CE1-3A
3 metre cable, bottom exit, gold contacts 14CE1-3G
Connector (dc), side exit 14CE1-AQ
Connector (dc), bottom exit 14CE1-Q
Top pin plunger, boot seal
Ø 7,0
(0.28) OP
24,6
(0.98)
Operating force (OF): 22,5 N [5.06 lb]
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE18-3
3 ft cable, side exit 914CE18-3A
6 ft cable, bottom exit 914CE18-6
9 ft cable, bottom exit 914CE18-9
9 ft cable, side exit 914CE18-9A
Connector (ac), side exit 914CE18-AQ1
Connector (dc), bottom exit 914CE18-Q
Connector (ac), bottom exit 914CE18-Q1
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE18-1
3 metre cable, bottom exit 14CE18-3
Connector (dc), bottom exit 14CE18-Q
Top pin plunger, panel mounted
M10x1 Thread
OP
29,2
(1.15)
NORTH AMERICA/GLOBAL CAT. LISTING
Connector (dc), bottom exit 914CE27-Q
Ball bearing plunger
OP
24,4
(0.96)
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE66-3
6 ft cable, bottom exit 914CE66-6
EUROPE/ CAT. LISTING
1 metre cable, bottom exit 14CE66-1
2 metre cable, bottom exit 14CE66-2
Adjustable plunger
OP
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE19-3
9 ft cable, bottom exit 914CE19-9
Manually operated
OP
27,4
(1.08)
Operating force (OF): 9,0 N [2.02 lb]
NORTH AMERICA/GLOBAL CAT. LISTING
6 ft cable, bottom exit 914CE22-6
Top roller plunger, parallel
Ø 12,4
(0.49) OP
28,4
(1.12)
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE2-3
3 ft cable, side exit 914CE2-3A
3 ft cable, bottom exit, gold contacts 914CE2-3G
6 ft cable, bottom exit 914CE2-6
6 ft cable, side exit 914CE2-6A
9 ft cable, bottom exit 914CE2-9
Connector (dc), side exit 914CE2-AQ
Connector (dc), bottom exit 914CE2-Q
Connector (ac), bottom exit 914CE2-Q1
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE2-1
1 metre cable, side exit 14CE2-1A
1 metre cable, bottom exit, gold contacts 14CE2-1G
2 metre cable, bottom exit 14CE2-2
2 metre cable, side exit 14CE2-2A
3 metre cable, bottom exit 14CE2-3
3 metre cable, side exit 14CE2-3A
3 metre cable, bottom exit, gold contacts 14CE2-3G
Connector (dc), side exit 14CE2-AQ
Connector (dc), bottom exit 14CE2-Q
Top roller plunger, parallel, boot
seal
Ø 12,4
(0.49) OP
34,4
(1.35)
Operating force (OF): 17,5 N [3.82 lb]
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE31-3
6 ft cable, bottom exit 914CE31-6
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE31-1
3 metre cable, bottom exit 14CE31-3
Top roller plunger, parallel,
panel mounted
OP
42,5
(1.67)
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE28-3
6 ft cable, bottom exit 914CE28-6
Connector (dc), bottom exit 914CE28-Q
25
www.honeywell.com/sensing
14CE/914CE Series
Plunger actuated switches
(continued)
Top roller plunger, perpendicular
Ø 12,4
(0.49) OP
28,5
(1.12)
5,1
(0.20)
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE3-3
6 ft cable, bottom exit 914CE3-6
6 ft cable, side exit 914CE3-6A
9 ft cable, bottom exit 914CE3-9
Connector (dc), bottom exit 914CE3-Q
Connector (ac), bottom exit 914CE3-Q1
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE3-1
2 metre cable, bottom exit 14CE3-2
3 metre cable, bottom exit 14CE3-3
Top roller plunger,
perpendicular, boot seal
OP
34,4
(1.35)
Operating force (OF): 17,5 N [3.82 lb]
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE55-3
3 ft cable, side exit 914CE55-3A
Top roller plunger,
perpendicular, panel mounted
OP
42,5
(1.67)
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE29-3
6 ft cable, bottom exit 914CE29-6
Side rotary and wobble
actuated switches
OPTIONS
Rotary motion
(actuating lever not included - use any
LSZ51*, LSZ52*, LSZ54*, LSZ55* or LSZ61*
Series shown on pages 71-73)
Operating torque: 0,3 Nm [2.66 in lb]
Pretravel (PT): 30° max.
Overtravel (OT) mm: 40° min.
Differential travel:
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE16-3
3 ft cable, side exit 914CE16-3A
6 ft cable, bottom exit 914CE16-6
9 ft cable, bottom exit 914CE16-9
Connector (dc), bottom exit 914CE16-Q
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE16-1
2 metre cable, bottom exit 14CE16-2
3 metre cable, bottom exit 14CE16-3
Wobble Spring wire
Operating Force (OF): 0,55 N [0.12 lb]
NORTH AMERICA/GLOBAL CAT. LISTING
3 ft cable, bottom exit 914CE20-3
6 ft cable, bottom exit 914CE20-6
9 ft cable, bottom exit 914CE20-9
Connector (dc), bottom exit 914CE20-Q
EUROPE CAT. LISTING
1 metre cable, bottom exit 14CE20-1
3 metre cable, bottom exit 14CE20-3
COMPACT LIMIT SWITCHES
26 www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
24CE/924CE Series
Miniature Safety
Electromechanical
Switches
Free position
Note: connector versions also available
2 Holes 5,1 dia
Counter Bored 10,2 dia x 6 deep
(both sides - option 'A' only)
Side exit cable
(Option 'A')
max.
40 /
1.58
max.
16 /
0.63
25 /
0.98
max.
49 /
1.93
8 /
0.32
1NC: 8,4 /
.33
1NC/1NO: 9,5 /
.374
For position sensing and switching applications requiring direct acting, positive opening contacts
the 24CE and 924CE ranges are ideal. They have been tested and approved to meet the requirements
of the Low Voltage directive and positive opening safety contacts per IEC/EN 60947-5-1-3. The
devices are CE marked. The red colour clearly differentiates this safety component in the application.
The 924CE range also has UL and CSA approval.
It is possible for the end user to enhance the safety level of these switches from Category 1 on their
own to Categories 2, 3 or 4 when the switches are used in conjunction with our wide range of FF-SR
safety relays to form a safety system.
Potential applications for these switches could use the roller plunger 24CE2- or 24CE3- style in
conjunction with cams on doors with hinges; or our fixed side rotary 24CE16- style for detection of
sliding doors. Also available are a range of panel mounting or top mounting versions to ensure that
small space or difficult mounting can be simply achieved.
Several contact arrangements are available.
Mechanical life: 10 million
Sealing: standard type: IP66; with boot seal type: IP67
Operating temperature: 24CE 0 °C to 70 °C [32 °F to 158 °F]
Low temperature: -40 °C [-40 °F]
924CE 0 °C to 105 °C [32 °F to 221 °F]
Approvals: 24CE CE
AC15 B300
DC13 R300
924CE CSA, CE
per UL file #E41859, 10 A 250 Vac; 1/3 Hp 125-250 Vac
AC15 B300
DC13 R300
Connection: Harmonised CENELEC 3 or 5 x 0,75 mm2 cable (24CE)
SJTO 3 or 5 x 18 AWG cable (924CE)
Contacts: Silver
Switching options:
924CE 24CE
Slow action contacts (1NC)
black red
green
brownblue
green/yellow
Slow action contacts (1NC/1NO), Break Before Make (BBM)
Zb
white
redblack
white
green
Zb
black
brownblue
black
green/yellow
Slow action contacts (1NC/1NO), Make Before Break (MBB)
white
green
red
white
black
Zb
Electrical ratings: IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A) VA
. . . . .
Category
at rated operational voltage Ue rating
120 V 240 V 380 V 480 V 500 V 600 V Make Break
AC15 B300 3 1.5 - - - - 3600 360
125 V 250 V
DC13 R300 0,22 0,1 28 28
Actuators
27
www.honeywell.com/sensing
24CE/924CE Series
OPTIONS
Side rotary
PTPT
OTOT
DT
DT
North America/Global
CABLE LENGTH CONTACT CAT. LISTING
3 ft 1NC, BBM 924CE16-S3
9 ft 1NC, BBM 924CE16-S9
3 ft 1NC, MBB 924CE16-T3
3 ft 1NC 924CE16-Y3
9 ft 1NC 924CE16-Y9
Europe
CABLE LENGTH CONTACT CAT. LISTING
1 m 1NC/1NO, BBM 24CE16-S1
1 m 1NC 24CE16-Y1
6 m 1NC 24CE16-Y6
Top pin plunger
17,5
max.
ø10
North America/Global
CABLE LENGTH CONTACT OPTION CAT. LISTING
3 ft 1NC, BBM 924CE1-S3
6 ft 1NC, BBM 924CE1-S6
9 ft 1NC, BBM 924CE1-S9
25 ft 1NC, MBB side exit 924CE1-T25A
3 ft 1NC, MBB 924CE1-T3
3 ft 1NC, MBB side exit 924CE1-T3A
6 ft 1NC, MBB side exit 924CE1-T6A
9 ft 1NC, MBB 924CE1-T9
9 ft 1NC, MBB side exit 924CE1-T9A
3 ft 1NC 924CE1-Y3
9 ft 1NC 924CE1-Y9
Europe
CABLE LENGTH CONTACT OPTION CAT. LISTING
12 m 1NC/1NO, BBM low temperature 24CE1-S12B
2 m 1NC/1NO, BBM 24CE1-S2
2 m 1NC/1NO, BBM side exit 24CE1-S2A
2 m 1NC/1NO, BBM low temperature 24CE1-S2B
3 m 1NC/1NO, BBM 24CE1-S3
6 m 1NC/1NO, BBM 24CE1-S6
1 m 1NC side exit 24CE1-Y1A
2 m 1NC 24CE1-Y2
3 m 1NC 24CE1-Y3
Top pin plunger, boot sealed
24,3 max.
ø7,1
North America/Global
CABLE LENGTH CONTACT CAT. LISTING
6 ft 1NC/1NO, BBM 924CE18-S6
Adjustable plunger
OP
North America/Global
CABLE LENGTH CONTACT OPTION CAT. LISTING
3 ft 1NC/1NO, BBM low temperature 924CE19-S3L1
Top roller plunger, parallel
30,3 max.
ø12,4
North America/Global
CABLE LENGTH CONTACT OPTION CAT. LISTING
15 ft 1NC, BBM 924CE2-S15
21 ft 1NC, BBM 924CE2-S21
3 ft 1NC, BBM 924CE2-S3
6 ft 1NC, BBM 924CE2-S6
6 ft 1NC, BBM side exit 924CE2-S6A
9 ft 1NC, BBM 924CE2-S9
25 ft 1NC, MBB 924CE2-T25
25 ft 1NC, MBB side exit 924CE2-T25A
3 ft 1NC, MBB 924CE2-T3
6 ft 1NC, MBB 924CE2-T6
9 ft 1NC, MBB 924CE2-T9
3 ft 1NC 924CE2-Y3
9 ft 1NC 924CE2-Y9
Europe
CABLE LENGTH CONTACT OPTION CAT. LISTING
1 m 1NC/1NO, BBM 24CE2-S1
2 m 1NC/1NO, BBM 24CE2-S2
2 m 1NC/1NO, BBM side exit 24CE2-S2A
2 m 1NC/1NO, BBM low temperature 24CE2-S2B
3 m 1NC/1NO, BBM 24CE2-S3
6 m 1NC/1NO, BBM 24CE2-S6
2 m 1NC/1NO, MBB 24CE2-T2
1 m 1NC 24CE2-Y1
2 m 1NC 24CE2-Y2
2 m 1NC side exit 24CE2-Y2A
4 m 1NC 24CE2-Y4
6 m 1NC side exit 24CE2-Y6A
COMPACT LIMIT SWITCHES
28 www.honeywell.com/sensing
Top roller plunger, parallel,
boot sealed
36,1
max.
ø12,4
North America/Global
CABLE LENGTH CONTACT OPTION CAT. LISTING
6 ft 1NC, BBM 924CE31-S6
20 ft 1NC 924CE31-Y20
3 ft 1NC low temperature 924CE31-
Y3L1
Europe
CABLE LENGTH CONTACT OPTION CAT. LISTING
1 m 1NC/1NO, BBM 24CE31-S1
2 m 1NC/1NO, BBM 24CE31-S2
2 m 1NC/1NO, BBM low temperature 24CE31-S2B
5 m 1NC/1NO, BBM 24CE31-S5
1 m 1NC 24CE31-Y1
2 m 1NC 24CE31-Y2
3 m 1NC 24CE31-Y3
Top roller plunger, parallel,
panel mounted
27,7
(1.75)
North America/Global
CABLE LENGTH CONTACT CAT. LISTING
15 ft 1NC, BBM 924CE28-S15
Europe
CABLE LENGTH CONTACT CAT. LISTING
2 m 1NC/1NO, BBM 24CE28-S2
COMPACT LIMIT SWITCHES
Top roller plunger, perpendicular
30,3
max.
ø12,4
North America/Global
CABLE LENGTH CONTACT CAT. LISTING
3 ft 1NC, BBM 924CE3-S3
6 ft 1NC, BBM 924CE3-S6
9 ft 1NC, BBM 924CE3-S9
9 ft 1NC, MBB 924CE3-T9
Europe
CABLE LENGTH CONTACT CAT. LISTING
2 m 1NC/1NO, BBM 24CE3-S2
1 m 1NC 24CE3-Y1
2 m 1NC 24CE3-Y2
Top roller plunger,
perpendicular, boot sealed
36,1
max.
ø12,4
Europe
CABLE LENGTH CONTACT CAT. LISTING
1 m 1NC/1NO, BBM 24CE55-S1
2 m 1NC/1NO, BBM 24CE55-S2
1 m 1NC 24CE55-Y1
29
www.honeywell.com/sensing
LS Series
Compact Limit
Switches
LS Series compact limit switches are carefully designed for enhanced repeatability under the most stringent
conditions. Compact size and field adjustable features greatly extend the flexibility of these switches. Heads may
be positioned at 90° increments. Side rotary models can be adjusted for clockwise and/or counter-clockwise
operation. Actuators can be set and locked in any position through 360°.
The rugged housings and actuator heads are constructed from cast aluminium, capable of withstanding
physical abuse. Protection against oil, water and dust is achieved by O-ring seals on the actuator shaft; a ring
seal between head and body; and a seated compression seal between cover and case.
The LS fits in many places too small for any other fully adjustable limit switch.
Conduit: ½ in - 14 NPT
20 mm
Sealing: ½ in - 14 NPT conduit NEMA 1, 3, 4, 6, 13
20 mm conduit IP67
Operating temperature: Standard -29 °C to 71 °C [-20 °F to 160 °F]
High -29 °C to 121 °C [-20 °F to 250 °F]
Approvals: LS-L UL, CSA
Contacts: Electrical ratings A, B, C, D, E Silver Cadmium Oxide (1)
Electrical ratings F, G Fine Silver
Switching options: SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
4
1
3
2
Electrical ratings: A 10 A, 120, 240 or 480 Vac; 1/3 hp, 120 Vac; ¾ hp, 240 Vac;
0.8 A, 115 Vdc**; 0.4 A, 230 Vdc;** 0.1 A, 550 Vdc;**
Pilot Duty, 600 Vac max.
B 10 A, 120, 240 or 480 Vac; ¼ hp, 120 Vac; ½ hp, 240 Vac.
Pilot Duty, 600 Vac max.
C 10 A, 120 Vac; 1/3 hp, 120 Vac.
D 10 A, 120, 240, 480 Vac; ¼ hp, 120 Vac; ½ hp, 240 Vac;
0.8 A, 115 Vdc**; 0.4 A, 230 Vdc**; 0.1 A, 550 Vdc**;
Pilot Duty, 600 Vac max.
E 10 A, 120, 240 or 480 Vac; 1/3 hp, 120 Vac; ¾ hp, 240 Vac.
Pilot Duty, 600 Vac max.
F UL Rating:
10 A, 125, 250, or 480 Vac; 1/3 hp, 125 Vac; ¾ hp, 250 Vac;
0.8 A, 125 Vdc**; 0.4 A, 250 Vdc**
G UL Rating:
10 A, 125, 250 or 480 Vac; ¼ hp, 125 Vac; ½ hp, 250 Vac;
0.8 A, 125 Vdc**; 0.4 A, 250 Vdc**
** Resistive rating
(1) Designed for use with inductive loads such as relays, contactors, motors and solenoids. Honeywell does
not
recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are
generally loads less than 12 volts and/or 0.5 amp.
COMPACT LIMIT SWITCHES
Actuators
30 www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
LS Series
Side rotary actuated switches
OPTIONS
Fixed length lever
Operating force max. (OF): Standard 13,3 N [3.0 lb]
Low 5,0 N [18 oz]
Pretravel max. (PT): Standard 20°
Low
Overtravel min. (OT) 30°
Differential travel max. (DT): Standard 12°
Low
Switching options: SPDT
Lever: Aluminium, steel roller
CONDUIT ELECTRICAL RATING CAT. LISTING
A 1LS1
F 1LS1-L
20 mm A 1LS1-4C
Low PT/OF B 1LS131
Low PT B 1LS19
Low PT 20 mm B 1LS19-4C
High temperature A 1LS243
High temperature 20 mm A 1LS243-4C
Indicator light C 1LS501
Low OF A 1LS6
Adjustable roller lever
Operating force max. (OF): Standard 13,3 N [3.0 lb]
Low 5,0 N [18 oz]
Pretravel max. (PT): Standard 20°
Low
Overtravel min. (OT) 30°
Differential travel max. (DT): Standard 12°
Low
Switching options: SPDT
Lever: Aluminium, nylon roller
CONDUIT ELECTRICAL RATING CAT. LISTING
A 1LS3
F 1LS3-L
20 mm A 1LS3-4C
Low PT B 1LS58
Low OF/PT/DT B 1LS59
31
www.honeywell.com/sensing
No lever
Note: Levers for are ordered separately
(see pages 71-73 for details)
Operating force max. (OF): Standard 0,51 N m [4.5 in
lb]
Low with standard PT 0,21 N m [30 in oz]
Low with low PT 0,11 N m [1 in lb]
Pretravel max. (PT): Standard 20°
Low
Maintained contact 55°
Overtravel min. (OT) Standard 30°
Maintained contact 35°
Differential travel max. (DT): Standard 12°
Low PT
Maintained contact 20°
Switching options: SPDT
Maintained contact
SPDT contact
CONDUIT ELECTRICAL RATING CAT. LISTING
A 1LS2
F 1LS2-L
20 mm A 1LS2-4C
Low OF A 1LS23
Low OF/PT B 1LS56
Low PT B 1LS9
Maintained contact
CONDUIT ELECTRICAL RATING CAT. LISTING
A 6LS2
F 6LS2-L
Adjustable rod
Operating force max. (OF): Standard 1,39 N [5 oz]
Low 0,83 Nm [3 oz]
Pretravel max. (PT): Standard 20°
Low
Overtravel min. (OT) 30°
Differential travel max. (DT): Standard 12°
Low
Switching options: SPDT
Lever: Aluminium rod
CONDUIT ELECTRICAL RATING CAT. LISTING
A 1LS10
F 1LS10-L
20 mm A 1LS10-4C
Low PT B 1LS47
Low PT/OF/DT B 1LS53
Side rotary, yoke lever, maintained contact
Operating force max. (OF): 8,9 N [2.0 lb]
Pretravel max. (PT): 55°
Switching options: Maintained
Lever: 6LS1Steel rollers on opposite sides of arm
6LS3 Nylon rollers on same side of arm
CONDUIT ELECTRICAL RATING CAT. LISTING
A 6LS1
20 mm A 6LS1-4C
A 6LS3
COMPACT LIMIT SWITCHES
32 www.honeywell.com/sensing
COMPACT LIMIT SWITCHES
LS Series
Plunger actuated switches
OPTIONS
Top pin plunger
Operating force max. (OF): Standard 31,14 N [7 lb]
Low 10 N [36 oz]
Pretravel max. (PT): 1,65 mm [0.065 in]
Overtravel min. (OT) Standard 6,35 mm [0.25 in]
Low 5,56 mm [0.219 in]
Differential travel max. (DT): Standard 0,51 mm [0.020 in]
Low 0,23 mm [0.009 in]
Switching options: SPDT
CONDUIT ELECTRICAL RATING CAT. LISTING
A 2LS1
F 2LS1-L
20 mm A 2LS1-4C
Low OF/OT/DT E 2LS111
Top roller plunger
Operating force max. (OF): 31,14 N [7 lb]
Pretravel max. (PT): 1,65 mm [0.065 in]
Overtravel min. (OT) 5,56 mm [0.219 in]
Differential travel max. (DT): 0,51 mm [0.020 in]
Switching options: SPDT
CONDUIT ELECTRICAL RATING CAT. LISTING
A 5LS1
F 5LS1-L
20 mm A 5LS1-4C
Side pin plunger
Operating force max. (OF): 40,03 N [9 lb]
Pretravel max. (PT): 2,8 mm [0.110 in]
Overtravel min. (OT) 6,35 mm [0.25 in]
Differential travel max. (DT): 1,02 mm [0.040 in]
Switching options: SPDT
CONDUIT ELECTRICAL RATING CAT. LISTING
A 4LS1
20 mm A 4LS1-4C
Side roller plunger
Operating force max. (OF): 40,03 N [9 lb]
Pretravel max. (PT): 2,8 mm [0.110 in]
Overtravel min. (OT) 5,56 mm [0.219
in]
Differential travel max. (DT): 1,02 mm [0.040
in]
Switching options: SPDT
CONDUIT ELECTRICAL RATING CAT. LISTING
A 3LS1
20 mm A 3LS1-4C
33
www.honeywell.com/sensing
Wobble actuated switches
These switches will operate by moving actuator in
any direction except direct pull.
Operating force max. (OF): 1,39 N [5 oz]
Pretravel max. (PT): 28,6 mm [1,125
in]
Switching options: SPDT
OPTIONS
Flexible cable
141,0 ±2,54
(5,550 ±0.10)
Ø 4,80 ±0.08
(0.189 ±0.003)
CONDUIT ELECTRICAL RATING CAT. LISTING
D 8LS1
G 8LS1-L
20 mm D 8LS1-4C
Spring rod
CONDUIT ELECTRICAL RATING CAT. LISTING
D 8LS3
20 mm D 8LS3-4C
Coil spring
Ø 6,17 ±0.08
(0.264 ±0.003)
141,0 ±2,54
(5,550 ±0.10)
CONDUIT ELECTRICAL RATING CAT. LISTING
D 8LS152
20 mm D 8LS152-4C
Steel wire
Operating force max. (OF): 0,28 N [1 oz]
Pretravel max. (PT): 63,5 mm [2.5 in]
191,3
(7.53)
CONDUIT ELECTRICAL RATING CAT. LISTING
D 8LS125
20 mm D 8LS125-4C
COMPACT LIMIT SWITCHES
34 www.honeywell.com/sensing
BF Series
Plastic
Enclosed Basic
Switches
PRECISION LIMIT SWITCHES
BF Series Plastic Enclosed Basic Switches are available with a wide variety of actuators, and are designed for easy
mounting and wiring. BF switches are designed to allow mounting with the cover either towards or away from the
mounting surface.
Switches with lever type actuators are adjustable in two directions. The entire actuator can be rotated around its
mounting bushing, and the angle of the lever can also be changed.
Sealing: NEMA 1, 3, 4, 13
Operating temperature: -32 °C to 71 °C [-25 °F to 160 °F]
Approvals: UL
Termination: ½ in - 14NPT
Contacts: Silver
Electrical ratings: A 11 A - 125 Vac, 250 Vac or 277 Vac
B 5 A - 125 Vac, 250 Vac or 277 Vac
Switching options:
SPDT Single Pole, Double Throw,
Snap action contacts (1NC/1NO)
Plunger actuated switches
OPTIONS
Top pin plunger
58,7
2.31
73,5
2.89
35,1
1.38
15,5
0.61
17,5
0.69
4,9
0.19
44,5
1.75
65,28
2.57
Ø 7,1
0.28Max.
14,3
0.56
9,5
0.38
Conduit thread
Operating force max. (OF): 12,23 N [44 oz]
Differential travel max. (DT): 0,64 mm [0.025 in]
ACTUATOR POSITION ELECTRICAL RATING CAT. LISTING
Left B BFL1-BP1
Right B BFR1-BP1
Top roller arm, adjustable
58,7
2.31
73,5
2.89
35,1
1.38
15,5
0.61
17,5
0.69
4,9
0.19
44,5
1.75
73,6
2.90
9,5
0.38
39,9
1.57
23,1
0.91Max.
18,3
0.72
Operating force max. (OF): 10,56 N [38 oz]
Differential travel max. (DT): 1,65 mm [0.065 in]
ACTUATOR POSITION ELECTRICAL RATING CAT. LISTING
Left B BFL1-BL1
Right B BFR1-BL1
Actuators
35
www.honeywell.com/sensing
PRECISION LIMIT SWITCHES
Plunger actuated switches
(continued)
Top roller arm, adjustable, one
way
14,73
0.58
32,26
1.27
19,05
0.75
180˚
58,7
2.31
73,5
2.89
35,1
1.38
Ø 15,5
0.61
44,5
1.75
73,6
2.90
9,5
0.38
4,9
0.19
17,5
0.69
39,6
1.56
18,3
0.72
Operating force max. (OF):
Left 3,61 N [13 oz]
Right 10,56 N [38 oz]
ACTUATOR ELECTRICAL CAT. LISTING
POSITION RATING
Left B BFL1-BL3
Right B BFR1-BL3
Low force rod
58,7
2.31 73,5
2.89
44,5
1.75
73,6
2.90
9,5
0.38
4,9
0.19
14,73
0.58
35,1
1.38
Ø 15,5
0.61
17,5
0.69
18,3
0.72
250˚
Operating force max. (OF):
Left 10,56 N [38 oz]
Right 3,61 N [13 oz]
ACTUATOR ELECTRICAL CAT. LISTING
POSITION RATING
Left B BFL1-BL2
Right B BFR1-BL2
Wobble actuated switches
Operating force max. (OF): 1,95 N [7 oz]
OPTIONS
Coil spring
58,7
2.31
73,5
2.89
35,1
1.38
15,5
0.61
17,5
0.69
4,9
0.19
44,5
1.75
169,9
6.69
Ø 7,1
0.28Max.
14,3
0.56
9,5
0.38
ACTUATOR ELECTRICAL CAT. LISTING
POSITION RATING
Left A BFL1-AW1
Left B BFL1-BW1
Right B BFR1-BW1
Plastic
58,7
2.31 73,5
2.89
35,1
1.38
15,5
0.61
17,5
0.69
4,9
0.19
44,5
1.75
249,25
9.81
Ø 7,1
0.28
14,3
0.56
9,5
0.38
C
Type -BW3
ACTUATOR ELECTRICAL CAT. LISTING
POSITION RATING
Left, A BFL1-AW2
179,3 mm [7.06 in] length rod
Left, B BFL1-BW3
249,25 mm [9.8 in] length rod
Spring wire
14,7
0.58
35,1
1.38
15,5
0.61
17,5
0.69
44,5
1.75
4,9
0.19 9,5
0.38
168,8
6.65
14,3
0.56
Ø 1,02
0.05
73,5
2.89
58,7
2.31
ACTUATOR ELECTRICAL CAT. LISTING
POSITION RATING
Left B BFL1-BW4
Right B BFR1-BW4
36 www.honeywell.com/sensing
BZE/DTE Series
Compact Enclosed
Switches
The BZE/DTE Series general purpose enclosed limit switches offer enhanced precision operation
and sturdy actuation in a compact but rugged metal housing. The large wiring enclosure means
that the user can get access to wire the device simply. The switch incorporates high repeatability of
the switch point early in the travel of the switch. This is achieved through a very tolerant over-travel
mechanism aimed at reducing the effect of the application drift and the long-term accuracy of the
switch.
Conduit: ½ in - 14 NPT
Sealing: E6 NEMA 1
V6 NEMA 1, 3
Operating temperature: Standard -32 °C to 71 °C [-25 °F to 160 °F]
Low -40 °C to 71°C [-40 °F to 160 °F]
Approvals: UL, CSA, CE
Contacts: Electrical ratings A, B, C Silver
Electrical rating D Gold
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
DPDT Double Pole, Double Throw
Snap action contacts (2NC/2NO)
Electrical ratings:
A UL/CSA Rating: 15 A, 125, 250 or 480 Vac:
2 A, 600 Vac:
1
/
8
Hp, 125 Vac: ¼ Hp, 250 Vac:
½ A, 125 Vdc: ¼ A, 250 Vdc
B UL/CSA Rating: 10 A, 125 or 250 Vac:
0.3 A, 125 Vdc: 0.15 A, 250 Vdc
C UL/CSA Rating: 15 A, 125, 250 or 480 Vac;
¼ Hp, 125 Vac; ½ Hp, 250 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc
D UL/CSA Rating: 1 A - 125 Vac
PRECISION LIMIT SWITCHES
Actuators
37
www.honeywell.com/sensing
E6/V6
E6 (side mount) and V6 (flange mount) switches are offered with or without actuator seal boots. Both have a combination insulator/ seal cemented
inside the bottom enclosure. Lead washers are used to seal the mounting holes on side mount switches. All side mount switches are installed with #6
screws, except the BZE6-2RN7 (#8 screws). Removal of the bottom enclosure exposes the terminals for easy wiring.
PRECISION LIMIT SWITCHES
Top roller plunger, parallel
23,4
(0.92)
56,6
(2,23)OP
19,0
(0.75)
25,4
(1.00)
25,4
(1.00) 25,4
(1.00)
77,2
(3.04)
22,6
(0.89)
1/2-14 NPT
Threads
12,7 (0.50) Ø
X
4,6 (0.18) W
Roller
Side mount
with boot seal
25,4
(1.0)
19,0
(0.75)
69,6
(2.740)
22,6
(0.89)
12,7 (0.50) Ø
X
4,6 (0.18)
Wide Roller
49,61
(1.953)
OP Ø
15,75
(0.62)
Side mount
without boot seal
With boot seal
Operating force max. (OF): SPDT 2,50 N to 6,67 N [9 oz to 24 oz]
DPDT 5,56 N to 13,34 N [20 oz to 48 oz]
Pretravel max. (PT): SPDT 1,98 mm [0.078 in]
DPDT 2,8 mm [0.110 in]
Overtravel min. (OT): SPDT 5,56 mm [0.219 in]
DPDT 3,18 mm [0.125 in]
Differential travel max. (DT): SPDT 0,01 mm to 0,05 mm
[0.0004 in to 0.0020 in]
DPDT 1,52 mm [0.060 in]
Side mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RN80
DPDT B DTE6-2RN80
Flange mount
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A BZV6-2RN80
Without boot seal
Operating force max. (OF): SPDT 2,50 N to 3,61 N [9 oz to 13 oz]
DPDT 6,67 N to 13,34 N [24oz to 48 oz]
Pretravel max. (PT): SPDT 0,38 mm [0.015 in]
DPDT 3,58 mm [0.141 in]
Overtravel min. (OT): SPDT 3,55 mm [0.140 in]
DPDT 3,18 mm [0.125 in]
Differential travel max. (DT): SPDT 0,05 mm [0.002 in]
DPDT 1,52 mm [0.060 in]
Side mount
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RQ8
Field adjustable roller SPDT A BZE6-2RQ9
Field adjustable roller DPDT B DTE6-2RQ9
Flange mount
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A BZV6-2RQ8
Momentary contact
OPTIONS
Top pin plunger
2,0
(0.08)REF 23,4
(0.92)
43,7
(1.72)OP
19,0
(0.75)
25,4
(1.00)
25,4
(1.00) 25,4
(1.00)
21,1
(0.83)
77,2
(3.04) 77,2
(3.04)
22,6
(0.89)
Ø 8,4
(0.33)
1/2-14 NPT
Threads 1/2-14 NPT
Threads
10,6
(0.42) Ø 8,4
(0.33)
63,5
(2.50)OP
44,4
(1.75) 22,6
(0.89)
4,3
(0.17)Ø (2)
41,4
(1.63)
25,4
(1.00)
54,1
(2.13)
Side mount
with boot seal Flange mount
without boot seal
With boot seal
Operating force max. (OF):SPDT Standard 2,50 N to 6,67 N [9 oz to 24 oz]
SPDT Low temperature 4,17 N to 10,84 N [15 oz to 39 oz]
DPDT 6,95 N to 16,4 N [25 oz to 59 oz]
Pretravel max. (PT): SPDT 1,98 mm [0.078 in]
DPDT 2,8 mm [0.110 in]
Overtravel min. (OT): SPDT 5,56 mm [0.219 in]
DPDT 3,18 mm [0.125 in]
Differential travel max. (DT): SPDT 0.05 mm [0.002 in]
DPDT 1,52 mm [0.060 in]
Side mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RN
DPDT B DTE6-2RN
Low temperature/High OF SPDT A BZE6-2RN34
#8 screws SPDT A BZE6-2RN7
Gold contacts SPDT D BZE6-2RN72
Flange mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZV6-2RN
DPDT B DTV6-2RN
Without boot seal
Operating force max. (OF): SPDT 2,50 N to 3,61 N [9 oz to 13 oz]
DPDT 5,56 N to 11,12 N [20 oz to 40 oz]
Pretravel max. (PT): SPDT 0,38 mm [0.015 in]
DPDT 3,81 mm [0.150 in]
Overtravel min. (OT): SPDT 5,56 mm [0.219 in]
DPDT 2,24 mm [0.088 in]
Differential travel max. (DT): SPDT 0,05 mm [0.002 in]
DPDT 1,52 mm [0.060 in]
Side mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RQ
DPDT B DTE6-2RQ
Flange mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZV6-2RQ
38 www.honeywell.com/sensing
BZE/DTE Series
E6/V6 Momentary contact (continued)
Top roller plunger, perpendicular
Flange mount
without boot seal
56,6
(2,23)OP
19,0
(0.75)
25,4
(1.00)
25,4
(1.00) 77,2
(3.04)
22,6
(0.89)
12,7 (0.50) Ø
X
4,6 (0.18) W
Roller
Side mount
with boot seal
With boot seal
Operating Force max. (OF): 2,60 N to 6,67 N [9 oz to 24 oz]
Pretravel max. (PT): 1,98 mm [0.078 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
Differential travel max. (DT): 0,01 mm to 0,05 mm
[0.0004 in to 0.0020 in]
Side mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RN81
Without boot seal
Operating Force max. (OF): SPDT 2,50 N to 3,61 N [9 oz to 13 oz]
DPDT 6,67 N to 13,34 N [24 oz to 48 oz]
Pretravel max. (PT): SPDT 0,38 mm [0.015 in]
DPDT 3,58 mm [0.141 in]
Overtravel min. (OT): SPDT 3,55 mm [0.140 in]
DPDT 3,18 mm [0.125 in]
Differential travel max. (DT): SPDT 0,05 mm [0.002 in]
DPDT 1,52 mm [0.060 in]
Side mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RQ81
DPDT B DTE6-2RQ81
Flange mount
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZV6-2RQ81
Roller arm, adjustable
Side mount
without boot seal Flange mount
with boot seal
Operating temperature: Standard -32 °C to 71 °C [-25 °F to 160 °F]
Low -40 °C to 71 °C [-40 °F to 160 °F]
Roller: Steel
With boot seal
Operating Force max. (OF): 2,78 N to 5,56 N [10 oz to 20 oz]
Pretravel max. (PT): 4,78 mm [0.188 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
Differential travel max. (DT): SPDT 0,15 mm [0.006 in]
DPDT 4,19 mm [0.165 in]
Side mount
Operating Force max. (OF): DPDT 13,34 N [48 oz]
Pretravel max. (PT): DPDT 7,92 mm [0.312 in]
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZE6-2RN2
DPDT B DTE6-2RN2
Low temperature SPDT A BZE6-2RN234
Flange mount
Operating Force max. (OF): DPDT 2,78 N to 8,34 N [10 oz to 30 oz]
Pretravel max. (PT): DPDT 6,76 mm [0.266 in]
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A BZV6-2RN2
DPDT B DTV6-2RN2
Without boot seal
Operating Force max. (OF): 2,78 N to 5,00 N [10 oz to 20 oz]
Pretravel max. (PT): 4,78 mm [0.188 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
Differential travel max. (DT): 0,15 mm [0.006 in]
CONTACT ELECTRICAL RATING CAT. LISTING
Side mount SPDT A BZE6-2RQ2
Flange mount SPDT A BZV6-2RQ2
PRECISION LIMIT SWITCHES
39
www.honeywell.com/sensing
One way roller lever
Side mount
with boot seal
With boot seal
Operating Force max. (OF): 2,22 N to 5,56 N [8 oz to 20 oz]
Pretravel max. (PT): 5,94 mm [0.234 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
Differential travel max. (DT): 0,15 mm [0.006 in]
CONTACT ELECTRICAL RATING CAT. LISTING
Side mount SPDT A BZE6-2RN28
Rod lever
Pretravel max. (PT): 18,24 mm [0.718 in]
Overtravel min. (OT): 21,29 mm [0.838 in]
Differential travel max. (DT): 5,82 mm [0.229 in]
Flange mount
without boot seal Side mount
with boot seal
Ø 15,75
(0.62)
25,4
(1.00)
77,2
(3.04)
69,60
(2,74)
22,6
(0.89)
19,05
(0.75)
250˚
152,4
(6.0)
18,29
(0.72)
53,19
(2.09)
With boot seal
Operating force max. (OF): 0,83 N to 1,95 N [3 oz to 7 oz]
CONTACT ELECTRICAL RATING CAT. LISTING
Side mount SPDT A BZE6-2RN62
Flange mount SPDT A BZV6-2RN62
Without boot seal
Operating force max. (OF): 0,56 N to 1,39 N [2 oz to 5 oz]
CONTACT ELECTRICAL RATING CAT. LISTING
Side mount SPDT A BZE6-2RQ62
Flange mount SPDT A BZV6-2RQ62
Manual palm button
Side mount
with boot seal
36,6
1.44
18,3
0.72 31,8
1.25
1/2 - 14 NPSM
5 THREADS MIN
78,5
3.09
44,4
1.75
77,2
3.04
22,6
0.89
4,3
0.17Ø (2)
41,4
1.63
38,1
1.50
25,4
1.00
54,1
2.13
With boot seal
Operating force max. (OF): 2,78 N to 5,56 N [10 oz to 20 oz]
Pretravel max. (PT): 4,78 mm [0.188 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
Differential travel max. (DT): 0,15 mm [0.006 in]
CONTACT ELECTRICAL RATING CAT. LISTING
Flange mount SPDT A BZV6-2RN4
Wobble, coil spring
These switches will operate by moving actuator in any direction except direct
pull.
Flange mount
with boot seal
With boot seal
Operating force max. (OF): 1,95 N [7 oz]
Pretravel max. (PT): 15°
CONTACT ELECTRICAL RATING CAT. LISTING
Side mount SPDT A BZE6-2RN18
Flange mount SPDT A BZV6-2RN18
PRECISION LIMIT SWITCHES
40 www.honeywell.com/sensing
BZE/DTE Series
E6/V6 Maintained contact (reset) switches
The switches shown below provide maintained contact after the
operating force on either top or bottom plunger is released.
Note: The top plungers on these switches provide enhanced accuracy
and uniform operation than the “reset” plungers and should be used
when closely held operating characteristics are required.
Switching:
SPDT Single Pole, Double Throw
(1NC/1NO) Maintained
OPTIONS
Top pin plunger
Side mount
with boot seal Flange mount
without boot seal
Side mount
Operating force max. (OF): With boot seal 1,67 N to 5,56 N [6 oz to 20 oz]
Without boot seal 1,67 N to 2,64 N [6 oz to 9.5 oz]
Pretravel max. (PT): With boot seal 1,98 mm [0.078 in]
Without boot seal 0.30 mm [0.012 in]
Overtravel min. (OT): 4,75 mm [0.187 in]
CONTACT ELECTRICAL RATING CAT. LISTING
With boot seal SPDT Maintained C BZE6-RNX1
Without boot seal SPDT Maintained C BZE6-RQX2
Top roller plunger
Side mount
without boot seal
56,69
(2.232)
53,19
(2.094)
Reset
FP
19,0
(0.75)
25,4
(1.00) 22,6
(0.89)
Ø 15,75
(0.62)
Ø 25,4
(1.0)
40,08
(1.58)
14,22
(0.56)
23,19
(0.913)
69,59
(2.74)
Ø 12,7 (0.50) x 4,6 (0.18)
Wide roller
Side mount
with boot seal
Side mount
Operating force max. (OF): With boot seal 3,34 N to 15,57 N [12 oz to 56 oz]
Without boot seal 1,67 N to 2,64 N [6 oz to 9.5 oz]
Pretravel max. (PT): With boot seal 1,98 mm [0.078 in]
Without boot seal 0,30 mm [0.012 in]
Overtravel min. (OT): With boot seal 4,75 mm [0.187 in]
Without boot seal 3,55 mm [0.140 in]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
With boot seal SPDT C BZE6-RN80X2
Without boot seal SPDT C BZE6-RQ8X2
Roller arm, adjustable
Flange mount
with boot seal Side mount
without boot seal
Side mount
Operating Force max. (OF): With boot seal 4,45 N [16 oz]
Without boot seal 3,34 N [12 oz]
Pretravel max. (PT): 4,78 mm [0.188 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
With boot seal Maintained C BZE6-RN2X1
Without boot seal Maintained C BZE6-RQ2X2
PRECISION LIMIT SWITCHES
41
www.honeywell.com/sensing
E7 Metal standard enclosed switch
Mechanical life: 10 million
Sealing: Without boot seal IP50 Standard
With boot seal IP65 Sealed
Operating temperature: -30 °C to 70 °C [-22 °F to 158 °F]
Approvals: IEC 60947-5-1
EN 60947-5-1
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
DPDT Double Pole, Double Throw
Snap action contacts (2NC/2NO)
OPTIONS
Top pin plunger
With boot seal
38,58
(1.519)
1,93
(0.076)
Pretravel
13,97
(0.55)
25,4
(1.00)
5,84
(0.23) 4,06
(0.16) 12,7
(0.50)
Ø 14,73
(0.58)
OP
Ø 8,38
(0.33)
76,40
(3,01)
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT PG 13.5 BZE7-2RN-PG
SPDT 20 mm BZE7-2RN-C
DPDT PG 13.5 DTE7-2RN-PG
Without boot seal
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT PG 13.5 BZE7-2RQ-PG
Top roller plunger, parallel, without boot seal
44,5
(1.75)
3,8
(0.15)
Pretravel
13,97
(0.55)
25,4
(1.00)
5,84
(0.23) 4,06
(0.16) 12,7
(0.50)
Ø 14,73
(0.58)
OP
Ø 12,7 x 4,5 wide roller
(Ø 0.50 x 0.18)
76,40
(3,01)
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT PG 13.5 BZE7-2RQ8-PG
Top roller plunger, perpendicular, without boot seal
44,53
(1.75)
0,38
(0.015)
Pretravel
13,97
(0.55)
25,4
(1.00)
5,84
(0.23) 4,06
(0.16) 12,7
(0.50)
Ø 14,73
(0.58)
OP
Ø 12,7 x 4,57
(0.50 x 0.18)
76,40
(3,01)
Wide roller
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT PG 13.5 BZE7-2RQ81-PG
Top roller lever, boot seal
48,11
(1.894)
13,97
(0.55)
25,4
(1.00)
5,84
(0.23) 4,06
(0.16) 12,7
(0.50)
Ø 14,73
(0.58)
Ø 19,05 x 7,92 wide roller
(Ø 0.75 x 0.312)
76,40
(3,01)
225˚
18,29
(0.72)
39,88
(1.57)
24,38
(0.91)
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT PG 13.5 BZE7-2RN2-PG
SPDT 20 mm BZE7-2RN2-C
Wobble, coil spring, boot seal
151,13
(5.95)
13,97
(0.55)
25,4
(1.00)
5,84
(0.23) 4,06
(0.16) 76,40
(3,01)
12,7
(0.50)
Ø 14,73
(0.58)
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT PG 13.5 BZE7-2RN18-PG
PRECISION LIMIT SWITCHES
Actuators
42 www.honeywell.com/sensing
PRECISION LIMIT SWITCHES
BAF/DTF
Series
High Capacity
Enclosed
Switches
The BAF/DTF Series is available with or without boot seals. The
elastomer boot on sealed actuator versions protects the actuating
mechanism and the internal basic switch from contamination. They are
therefore potentially suitable for wash-down applications. Both sealed
and unsealed versions are available with the actuators on the right or left
hand side.
The cover plate is removable to allow ease of wiring and switch
replacement without having to dismount the housing.
The BAF/DTF Series is potentially suitable for use in packaging
equipment, farm machinery, conveyors, overhead cranes and hoists.
Approvals: UL, CSA
Sealing: NEMA 1, 3, 4, 13
-2RQ9 NEMA 1
Operating temperature: -32 °C to 71 °C [-25 °F to 160 °F]
Conduit: ½ in - 14 NPT
Contacts: Silver
Electrical ratings: B UL/CSA Rating: 10 A, 125 or 250 Vac;
0.3 A, 125 Vdc; 0.15
A, 250 Vdc.
D UL/CSA Rating: 20 A, 125, 250 or 480 Vac;
1 Hp, 125 Vac; 2 Hp, 250 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc;
Lamp Load - 10 A, 125 Vac.
Switching options:
D SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
B DPDT Double Pole, Double Throw
Snap action contacts (2NC/2NO)
Momentary contact
OPTIONS
Top pin plunger
Left-hand Right-hand
*28,2 on DTF2 Types
1.11
With boot seal
Operating force max. (OF): BAF/DTF 11,2 N [2.5 lb]
Pretravel max. (PT): BAF 2,39 mm [0.094 in]
DTF 3,59 mm [0.141 in]
Overtravel min. (OT): BAF 5,56 mm [0.219 in]
DTF 3,96 mm [0.156 in]
Differential travel max. (DT): BAF 0,26 mm [0.010 in]
DTF 1,53 mm [0.060 in]
Operating position (OP): BAF 53,19 mm [2.094 in]
DTF 52,07 mm [2.050 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RN-RH
Left SPDT D BAF1-2RN-LH
Right DPDT B DTF2-2RN-RH
Left DPDT B DTF2-2RN-LH
Actuators
43
www.honeywell.com/sensing
PRECISION LIMIT SWITCHES
Momentary contact (continued)
Top roller plunger, parallel
Right-hand Left-hand
*28,2 on DTF2 Types
1.11
O-ring actuator seal
Operating force max. (OF): BAF/DTF 35,6 N [8.0 lb]
Pretravel max. (PT): BAF/DTF 3,18 mm [0.125 in]
Overtravel min. (OT): BAF 4,75 mm [0.187 in]
DTF 3,18 mm [0.125 in]
Differential travel max. (DT): BAF 0,19 mm [0.0075 in]
DTF 1,53 mm [0.060 in]
Operating position (OP): BAF 64,69 mm [2.547 in]
DTF 63,88 mm [2.515 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RQN8-RH
Left SPDT D BAF1-2RQN8-LH
Right DPDT B DTF2-2RQN8-RH
Left DPDT B DTF2-2RQN8-LH
Field adjustable roller plunger
Adjustable 360° horizontally
Operating force max. (OF): BAF/DTF 11,2 N [2.5 lb]
Pretravel max. (PT): BAF 2,39 mm [0.094 in]
DTF 3,18 mm [0.125 in]
Overtravel min. (OT): BAF 3,96 mm [0.156 in]
DTF 3,18 mm [0.125 in]
Differential travel max. (DT): BAF 0,26 mm [0.010 in]
DTF 1,53 mm [0.060 in]
Operating position (OP): BAF 64,69 mm [2.547 in]
DTF 63,88 mm [2.515 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RQ9-RH
Left SPDT D BAF1-2RQ9-LH
Right DPDT B DTF2-2RQ9-RH
Left DPDT B DTF2-2RQ9-LH
Roller arm, adjustable
With boot seal
Operating force max. (OF): BAF 8,90 N [2.0 lb]
DTF 11,1 N [2.5 lb]
Pretravel max. (PT): BAF 5,56 mm [0.219 in]
DTF 7,93 mm [0.312 in]
Overtravel min. (OT): BAF 6,35 mm [0.25 in]
DTF 5,56 mm [0.219 in]
Differential travel max. (DT): BAF 0,51 mm [0.020 in]
DTF 3,05 mm [0.120 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RN2-RH
Left SPDT D BAF1-2RN2-LH
Right DPDT B DTF2-2RN2-RH
Right DPDT B DTF2-2RN2-LH
One way roller lever
With boot seal
Operating force max. (OF): 8,90 N [2.0 lb]
Pretravel max. (PT): 5,56 mm [0.219 in]
Overtravel min. (OT): 6,35 mm [0.25 in]
Differential travel max. (DT): 0,51 mm [0.020 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RN28-RH
Left SPDT D BAF1-2RN28-LH
44 www.honeywell.com/sensing
BAF/DTF Series
Momentary contact (continued)
Manual palm button
Left-hand *28,2 on DTF2 Types
1.11
With boot seal
Operating force max. (OF): 8,90 N [2.0 lb]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RN4-RH
Left SPDT D BAF1-2RN4-LH
Wobble, coil spring
Left-hand Right-hand
With boot seal
Pretravel max. (PT): 15°
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right SPDT D BAF1-2RN18-RH
Left SPDT D BAF1-2RN18-LH
Maintained contact (reset) switches
Top pin plunger
Right-hand
With boot seal
Operating force max. (OF): 7,79 N [1.75 lb]
Pretravel max. (PT): 2,39 mm [0.094 in]
Overtravel min. (OT): 5,56 mm [0.219 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right Maintained SPDT D BAF1-3RNX1
Roller arm, adjustable
82,6
(3.25)
101,6
(4.00)
With boot seals on roller arm and plunger
Operating force max. (OF): 6,67 N [1.5 lb]
Pretravel max. (PT): 5,56 mm [0.219 in]
Overtravel min. (OT): 6,35 mm [0.25 in]
Operating position (OP): 60,71 mm [2.390 in]
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right Maintained SPDT D BAF1-3RN2X-RH
Left Maintained SPDT D BAF1-3RN2X-LH
PRECISION LIMIT SWITCHES
45
www.honeywell.com/sensing
Wobble, coil spring
82,6
(3.25)
41,4
(1.63) 27,4
(1.08)
27,4
(1.08)
158,5
(6.24)
32,5
(1.28)
20,6
(0.81)
101,6
(4.00)
Ø 7,1
(0.28)
Ø 6,9
(0.27)
(3)
1/2-14 NPT
Threads
With boot seals on wobble stick and plunger
Pretravel max. (PT): 15°
ACTUATOR POSITION CONTACT ELECTRICAL RATING CAT. LISTING
Right Maintained SPDT D BAF1-3CN18X1
PRECISION LIMIT SWITCHES
46 www.honeywell.com/sensing
HEAVY DUTY LIMIT SWITCHES
HDLS Series
Heavy Duty Limit
Switches
The HDLS Series Heavy Duty Limit Switches offer a wide choice of mounting and actuator options.
Housed in a rugged, die-cast zinc body, the switch is epoxy coated for protection. Potential
applications include harsh duty environments where conventional limit switches may not be used.
Versatile and full featured, they are designed for long life.
Listings referenced in this section are mainly standard. Low temperature and fluorocarbon (FC,
high temperature) construction is available in all forms of HDLS limit switches. For temperature
ranges see table opposite. Also available are factory sealed, pre-wired switches.
Low temperature switches have fluorosilicone diaphragm, shaft seals and external boot seal
(where applicable) plus a low temperature lubricant. If prewired with cable, temperature limits are -
10 °C [14 °F] flex and -30 °C [22 °F] no flex.
To order a low temperature version insert the additional letters Y and B as in the following example:
LSA1A - standard side rotary plug-in switch
LSYAB1A - low temperature version.
Completely fluorocarbon (FC) sealed, high temperature, chemical resistance switches have a
full FC body gasket covering the switch cavity. Rotary types have an extra FC seal on the operating
shaft, while plunger versions have FC boot seals. They are for use in potential applications where
the environment includes fire-resistant synthetic fluids. The additional FC seals also promote
enhanced operating life for rotary actuacted HDLS switches in applications where the temperatures
are normally -12 °C to 121 °C [10 °F to 250 °F]. If prewired with cable, temperature limits are
105 °C [221 °F] dry and 60 °C [140 °F] wet.
To order a fluorocarbon (FC) sealed switch insert the additional letters Y and C as in the following
example:
LSA1A - standard side rotary plug-in switch
LSYAC1A - completely FC sealed version.
Factory sealed, pre-wired limit switches have the entry area completely sealed and are available
with 6 ft [1,83 m], STOOW-A cable or 4, 5 or 9-pin connectors. NEMA ratings are, for cable
version 1, 4, 6, 6P, 12, for connector version 1, 4, 6, 6P, 12, 13.
To order a factory sealed switch add the appropriate letter:
Circuitry Cable ½ in Connector (available with ½ in conduit tap
only)
SPDT CA (4 pin mini)
B (5 pin mini)
DD (4 pin micro)
DPDT M (¾ in only) R (9 pin)
Example:
LSA1AC - LSA1A with 6 ft of 5 conductor STOOW-A cable
LSJ2BM-7N - LSJ2B-7N with 6 ft of 9 conductor STOOW-A cable
LSA1AB - LSA1A with 5 pin receptable
LSA1ADD - 4 pin micro-change connector
Electrical ratings
10 amps continuous carry. Circuits on any one pole must be the same polarity.
ac Volts
Pilot duty: 600 Vac, 720 VA
Amps at 0.35 Power Factor
Vac Make Break
A 120 60 6
SPDT 240 30 3
NEMA 480 15 1.5
A600 600 12 1.2
B 120 30 3
DPDT 240 15 1.5
NEMA 480 7.5 0.75
B600 600 6 0.60
C 250 Vac or 60 Vdc, 0.050 amp max.
SPDT/DPDT
dc Volts
Pilot duty: 240 Vdc, 30 watts
Make and Break Amps
Vdc Inductive Resistive
A 120 0.25 0.8
SPDT 240 0.15 0.4
B 120 0.25 0.8
DPDT 240 0.15 0.4
C 250 Vac or 60 Vdc, 0.050 amp max.
SPDT/DPDT
Levers: Levers for side rotary
types are ordered separately (see
pages 71-73 for details)
Actuators
47
www.honeywell.com/sensing
HEAVY DUTY LIMIT SWITCHES
Operating temperatures
Environmental
seal
performance
48 www.honeywell.com/sensing
Side rotary, momentary action
The momentary action listings shown are factory
assembled with the head adjusted for both
clockwise (CW) and counterclockwise (CCW)
operation. The shaft of side rotary heads face the
front (label side of switch).
Actuation direction
A simple field adjustment converts switch to
accept actuation from one or both directions. For
ready reference, adjustment instructions are cast
into the internal lid of side rotary heads.
Head orientation
The head may be orientated and locked in any
of four 90° positions.
Momentary action switches can be factory
assembled for operation in one direction only
and/or with the shaft facing the rear or either
side. Contact Honeywell for more information.
HDLS Series Side rotary actuated switches
Levers: Levers for side rotary types are ordered separately (see
pages 69-71 for details)
Sealing IP67, 68 (except preleaded versions)
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
UL, CSA, CE, CCC
Operating force (Newton meters, N m/in lb):
LSA, LSL, LSM, LSM, LSP, LSU 0,45 N m
max.
4 in lb max.
LSH, LSR 0,19 N m max.
1.7 in lb max
Conduit: ½ in - 14 NPT
Contacts: Electrical ratings A, B Silver
Electrical rating C Gold
Switching options: Snap action contacts
SPDT DPDT
SPDT Double Break
DPDT Double Break
HEAVY DUTY LIMIT SWITCHES
49
www.honeywell.com/sensing
OPTIONS
Standard
Pretravel: 15° max.
Differential travel: SPDT max.
DPDT 7° max.
Overtravel: 60° min.
Plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSA1A
SPDT C LSA1E
DPDT ¾ in B LSA2B
DPDT B LSA6B
DPDT C LSA6S
SPDT 20 mm A LS4A1A
DPDT 20 mm B LS4A2B
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSA3K
DPDT ¾ in B LSA4L
SPDT 20 mm A LS4A3K
Low differential travel
Pretravel: 9° max.
Differential travel: SPDT 3° max.
DPDT 4° max.
Overtravel: 66° min.
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSP1A
SPDT C LSP1E
DPDT B LSP2B
DPDT B LSP6B
DPDT C LSP6S
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSP3K
DPDT ¾ in B LSP4L
Low torque
Pretravel: 15° max.
Differential travel: SPDT 5° max.
DPDT 7° max.
Overtravel: 60° min.
Plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSR1A
SPDT C LSR1E
DPDT ¾ in B LSR2B
DPDT B LSR6B
DPDT C LSR6S
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSR3K
DPDT ¾ in B LSR4L
HEAVY DUTY LIMIT SWITCHES
Low differential, low torque
Pretravel: 9° max.
Differential travel: SPDT max.
DPDT max.
Overtravel: 66° min.
Plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSH1A
SPDT C LSH1E
DPDT ¾ in B LSH2B
DPDT B LSH6B
DPDT C LSH6S
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSH3K
DPDT ¾ in B LSH4L
5° Pretravel
Pretravel: 5° max.
Differential travel: SPDT 3° max.
DPDT 4° max.
Overtravel: 70° min.
Plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSU1A
SPDT C LSU1E
DPDT ¾ in B LSU2B
DPDT B LSU6B
DPDT C LSU6S
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT A LSU3K
DPDT ¾ in B LSU4L
Side rotary, additional circuitry/
action
The following listings, sequential, centre neutral
and maintained switches, are assembled with
the operating shaft facing front. The user can
position and lock the head with the shaft to rear
or either side. They can also be factory
assembled with the shaft to rear or either side.
Contact Honeywell for more information.
OPTIONS
Sequential
One pole operates before the other in each
direction, with 10° lever travel between
operations.
Pretravel: 1st pole 15° max.
2nd pole additional 10° max.
Differential travel: Each pole 5° max.
Overtravel: 48° min.
Switching options:
(2) SPDT Double Bread
with 10˚ between operation
Plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
DPDT ¾ in B LSL2C
DPDT B LSL6C
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
DPDT ¾ in B LSL4M
DPDT B LSL7M
Centre neutral
One pole operates on clockwise rotation, the
other on counterclockwise rotation.
Pretravel: 18° max.
Differential travel: 10° max.
Overtravel: 57° min.
Switching options:
SPDT Double Break each direction
Plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
DPDT ¾ in B LSM2D
SPDT 20 mm B LS4M2D
DPDT B LSM6D
Non plug in
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
DPDT ¾ in B LSM4N
DPDT B LSM7N
50 www.honeywell.com/sensing
Top roller plunger
Operating point: 55,9 mm ± 1,02
2,20 in ± 0.040
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSD1A
SPDT C LSD1E
DPDT B LSD6B
DPDT C LSD6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSD3K
DPDT B LSD7L
Adjustable plunger
Operating point: 53,0 mm to 59,3 mm
2.085 in to 2.335 in
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSV1A
SPDT C LSV1E
DPDT B LSV6B
DPDT C LSV6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSV3K
DPDT B LSV7L
HDLS Series
Side rotary actuated
switches (continued)
Maintained contact, 2 position
Operation is maintained on counterclockwise
rotation, reset on clockwise rotation and vice
versa.
Pretravel: 65° max.
Differential travel: 40° max.
Overtravel: 20° min.
Switching options:
SPDT DPDT
SPDT Double Break
Maintained
DPDT Double Break
Maintained
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSN1A
DPDT B LSN6B
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSN3K
DPDT B LSN7L
Plunger actuated switches
HDLS plunger actuated switches are available
with either top or side facing plungers for
application flexibility. Switches with adjustable
plungers simplify installation. They have a hex
setscrew and locknut on the plunger, providing an
adjustment range of 0.25 in [6,35 mm].
Assembled conditions
The listing shown are factory assembled with side
plungers facing front (label side of switch); rollers
on side plungers are in horizontal position.
Rollers on top plunger switches are parallel to
mounting surface. Other options are available.
Contact Honeywell for more information.
Approvals: NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
UL, CSA, CE
Conduit: ½ in - 14 NPT
Contacts:
Electrical ratings A, B Silver
Electrical rating C Gold
Switching options: Snap action contacts
SPDT DPDT
SPDT Double Break
DPDT Double Break
Top plungers, momentary action
Pretravel: 1,78 mm [0.07 in] max.
Differential travel:
SPDT 0,38 mm [0.015 in] max.
DPDT 0,51 mm [0.02 in] max.
Overtravel: 4,83 mm [0.19 in] min.
Operating force: 17,8 N m [4 lb] max.
OPTIONS
Top pin plunger
Operating point: 45,8 mm ± 0,76
1.805 in ± 0.030
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSC1A
SPDT C LSC1E
DPDT B LSC6B
DPDT C LSC6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSC3K
DPDT B LSC7L
HEAVY DUTY LIMIT SWITCHES
51
www.honeywell.com/sensing
Side plungers, momentary action
Pretravel: 2,54 mm [0.100 in] max.
Differential travel:
SPDT 0,64 mm [0.025 in] max.
DPDT 0,89 mm [0.035 in] max.
Overtravel: 4,83 mm [0.19 in] min.
Operating force: 26,7 N m [6 lb] max.
OPTIONS
Side pin plunger
39,6
1.56
14,7
.58
20,3
.80
31,37
1.24
Operating point: 33 mm ± 0,76
1.300 in ± 0.030
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSE1A
SPDT C LSE1E
DPDT B LSE6B
DPDT C LSE6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSE3K
DPDT B LSE7L
Adjustable side pin plunger
Operating point: 41,0 mm to 47,4 mm
1.615 in to 1.865 in
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSW1A
SPDT C LSW1E
DPDT B LSW6B
DPDT C LSW6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSW3K
DPDT B LSW7L
HEAVY DUTY LIMIT SWITCHES
Side roller plunger
Operating point: 44,1 mm ± 1,02
1.735 in ± 0.040
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSF1A
SPDT C LSF1E
DPDT B LSF6B
DPDT C LSF6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSF3K
DPDT B LSF7L
Side plunger, maintained
circuitry
LSG contact transfer is maintained after either
plunger is operated. Operation of other plunger
resets switch.
Pretravel: 4,32 mm [0.170 in] max.
Differential travel:
SPDT 2,29 mm [0.090 in] max.
DPDT 2,29 mm [0.090 in] max.
Overtravel: 2,00 mm [0.0.80 in] max.
Operating force: 44,5 N m [10 lb] min.
Operating point: 37,6 ± 0,76 mm
1.48 ± 0.030 in
Switching options:
SPDT DPDT
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSG1A
SPDT C LSG1E
DPDT B LSG6B
DPDT C LSG6S
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSG3K
DPDT B LSG7L
52 www.honeywell.com/sensing
HDLS Series
Wobble actuated switches
Momentary action wobble actuated switches
have flexible levers which may be operated with
any movement, except direct pull.
Approvals: NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
UL, CSA, CE
Conduit: ½ in - 14 NPT
Contacts:
Electrical ratings A, B Silver
Switching options: Snap action contacts
SPDT DPDT
SPDT Double Break
DPDT Double Break
OPTIONS
Plastic rod
Pretravel (approx) (Radius):25,4 mm [1.0 in]
Operating force: 2,78 g [10 oz] max.
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSJ1A-7A
DPDT B LSJ6B-7A
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSJ3K-7A
DPDT B LSJ7L-7A
Spring wire
Pretravel (approx) (Radius): 102,0 mm [4.0 in]
Operating force: 1,39 g [5 oz] max.
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSJ1A-7M
DPDT B LSJ6B-7M
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSJ3K-7M
DPDT B LSJ7L-7M
Cable
Pretravel (approx) (Radius): 38,0 mm [1.5 in]
Operating force: 1,95 N [7.0 oz] max.
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSJ1A-7N
DPDT B LSJ6B-7N
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSJ3K-7N
DPDT B LSJ7L-7N
Cat whisker
Pretravel (approx) (Radius): 51,0 mm [2.0 in]
Operating force: 1,39 N [5.0 oz] max.
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSK1A-8A
DPDT B LSK6B-8A
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSK3K-8A
DPDT B LSK7L-8A
Coil spring
Pretravel (approx) (Radius): 51,0 mm [2.0 in]
Operating force: 1,95 N [7.0 oz] max.
Plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSK1A-8C
DPDT B LSK6B-8C
Non plug in
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LSK3K-8C
DPDT B LSK7L-8C
HEAVY DUTY LIMIT SWITCHES
53
www.honeywell.com/sensing
Fully potted HDLS
Fully potted HDLS are designed to meet the
demanding requirements of NEMA 1, 3, 4, 6, 6P
and 13 for wet applications where the integrity of
the conduit seal must be assured. These
switches are the same as the standard HDLS non
plug in limit switch except that the conduit
entrance is factory sealed to simplify installation
and ensure integrity of the conduit seal. They are
epoxy filled and supplied with six feet of 5 or 9
conductor 16 gauge STO cable. Fully potted
HDLS are built with all Fluorocarbon seals.
Sealing exceeds Nema 6P. Low temperature
versions are available, see page 46 for
temperature range and how to order.
106,7
4.20 59,4
2.34
19,0
0.75
29,4
1.16
70,4
2.77
36,6
1.44
25,4
1.00
5,2
0.20Ø Mtg holes
(2) 10-32 UNF tapped
from rear only (2)
41,1
1.62 39,6
1.56
14,7
0.58
62,0
2.44
Mtg pads
74,9
2.95
1/2-14 NPT
20,3
0.80
39,0
1.54
44,4
1.75
7,32
0.29
Approvals:
Connector NEMA 1, 4, 6, 6P, 12, 13
Cable NEMA 1, 4, 6, 6P, 12
UL, CSA, CE, CCC
Operating temperature:
Cable versions -12 °C to 105 °C
10 °F to 221 °F
Connector versions -12 °C to 121 °C
10 °F to 250 °F
Cable length: 3,658 m [12 ft]
Contacts: Electrical ratings A, B Silver
Switching options: Snap action contacts
SPDT DPDT
Wiring diagrams: Numbers = Connectors
Colours = Cables
Single-Pole Double-Pole
Side rotary actuated
switches
Levers: Levers for side rotary
types are ordered separately (see
pages 71-73 for details)
OPTIONS
Standard
Pretravel: 15° max.
Differential travel: SPDT 5° max.
DPDT 7° max.
Overtravel: 60° min.
Operating force: 0,45 N m [4 in lb] max.
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
SPDT Cable A LSYAC3KP-FP
DPDT Cable B LSYAC4LX-FP
SPDT 5-pin Connector A LSYAC3KQ-FP
DPDT 9-pin Connector B LSYAC7LR-FP
Low differential travel
Pretravel: 9° max.
Differential travel: SPDT 3° max.
DPDT 4° max.
Overtravel: 66° min.
Operating force: 0,45 N m [4 in lb] max.
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
SPDT Cable A LSYPC3KP-FP
DPDT Cable B LSYPC4LX-FP
SPDT 5-pin Connector A LSYPC3KQ-FP
DPDT 9-pin Connector B LSYPC7LR-FP
5° Pretravel
Pretravel: 5° max.
Differential travel: SPDT 3° max.
Overtravel: 70° min.
Operating force: 0,45 N m [4 in lb] max.
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
SPDT Cable A LSYUC3KP-FP
SPDT 5-pin Connector A LSYUC3KQ-FP
For low temperature versions
substitute “Y_B” for “Y_C”
HEAVY DUTY LIMIT SWITCHES
Actuators
54 www.honeywell.com/sensing
Fully potted HDLS
(continued)
Side rotary actuated
switches
Sequential
Pretravel: 1st pole 15° max.
2nd pole additional 10° max.
Differential travel: Each pole 5° max.
Overtravel: 48° max.
Operating force: 0,45 N m [4 in lb] max.
Switching options: DPDT
(2) SPDT Double Break
with 10˚ between operation
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
DPDT Cable B LSYLC4MX-FP
DPDT 9-pin Connector B LSYLC7MR-FP
Centre neutral
Pretravel: 18° max.
Differential travel: 10° max.
Overtravel: 57° min.
Operating force: 0,45 N m [4 in lb] max.
Switching options: DPDT
SPDT Double Break each direction
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
DPDT Cable B LSYMC4NX-FP
DPDT 9-pin Connector B LSYMC7NR-FP
For low temperature versions
substitute “Y_B” for “Y_C”
Plunger actuated switches
OPTIONS
Top plungers
Pretravel: 1,78 mm [0.07 in] max.
Differential travel:
SPDT 0,38 mm [0.015 in] max.
DPDT 0,51 mm [0.02 in] max.
Overtravel: 4,83 mm [0.19 in] min.
Operating force: 17,8 N m [4 lb] max.
Top pin plunger
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
SPDT Cable A LSYCC3KP-FP
DPDT Cable B LSYCC4LX-FP
SPDT 5-pin Connector A LSYCC3KQ-FP
DPDT 9-pin Connector B LSYCC7LR-FP
Top roller plunger
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
SPDT Cable A LSYDC3KP-FP
DPDT Cable B LSYDC4LX-FP
SPDT 5-pin Connector A LSYDC3KQ-FP
DPDT 9-pin Connector B LSYDC7LR-FP
Side plungers
Pretravel: 2,54 mm [0.100 in] max.
Differential travel:
SPDT 0,38 mm [0.015 in] max.
DPDT 0,51 mm [0.02 in] max.
Overtravel: 4,83 mm [0.19 in] min.
Operating force: 26,7 N m [6 lb] max.
Side pin plunger
CONTACT TERMINATION ELECTRICAL RATING CAT. LISTING
SPDT Cable A LSYEC3KP-FP
DPDT Cable B LSYEC4LX-FP
SPDT 5-pin Connector A LSYEC3KQ-FP
DPDT 9-pin Connector B LSYEC7LR-FP
Wobble actuated switches
Actuator codes **: Head style*
7A Delrin rod J
7M Spring wire J
8A Cat whisker K
7N Cable J
8C Coil spring K
CONTACT TERMINATION ELECTRICAL CAT. LISTING
RATING
SPDT Cable A LSY*C3KP-**FP
DPDT Cable B LSY*C4LX-**FP
SPDT 5-pin Connector A LSY*C3KQ-**FP
DPDT 9-pin Connector B LSY*C7LR-**FP
HEAVY DUTY LIMIT SWITCHES
55
www.honeywell.com/sensing
Stainless steel
HDLS
HDLS stainless steel switches are designed for
use in highly corrosive environments such as
petro-chemical plants, food processing plants,
shipboard and dockside locations. The type
316 cast stainless steel body is designed to
minimise crevices where food particles could
become trapped. The actuator, operating
head and screws are also stainless steel. All
seals are Fluorocarbon to provide excellent
chemical resistance and to withstand operating
temperatures up to 121 °C [250 °F] and
pressurised steam cleaning.
Approvals: NEMA 1, 3, 3R, 4, 4X, 6, 6P, 12,
13
UL, CSA, CE, CCC
Operating temperature: -12 °C to 121 °C
10 °F to 250 °F
Contacts: Electrical ratings A, B Silver
Levers: Levers for side rotary
types are ordered separately
(see pages 71-73 for details)
Side rotary actuated
switches
OPTIONS
Standard
Pretravel: 15° max.
Differential travel: SPDT 5° max.
DPDT 7° max.
Overtravel: 60° min
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LS2A4K
DPDT B LS2A4L
Low Torque
Pretravel: 9° max.
Differential travel: SPDT 3° max.
DPDT 4° max.
Overtravel: 60° min.
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LS2H4K
DPDT B LS2H4L
Centre neutral
Pretravel: 18° max
Differential travel: DPDT 10° max.
Overtravel: 57° min.
CONTACT ELECTRICAL RATING CAT. LISTING
DPDT B LS2M4N
Plunger actuated switches
OPTIONS
Top roller plunger
Pretravel: 1,78 mm [0.07 in] max.
Differential travel: 0,38 mm [0.015 in] max.
Overtravel: 4,83 mm [019 in] min.
Operating point: 55,9 mm ± 1,02
2.20 in ± 0.04
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LS2D4K
DPDT B LS2D4L
Side pin plunger
33,0
1.30
Operating
point
21,6
0.85
9,4
0.37
19,0
0.75
39,6
1.56
14,7
.58
20,3
.80
31,37
1.24
Pretravel: 2,54 mm [1.00 in] max.
Differential travel: 0,64 mm [0.025 in] max.
Overtravel: 4,83 mm [0.19 in] min.
Operating point: 33 mm ± 0,76
1.3 in ± 0.03
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LS2E4K
DPDT B LS2E4L
Side roller plunger
47,7
1.88
39,6
1.56
14,7
0.58
19,1
0.75
31,5
1.24
4,8
0.19
44,2
1.74
Operating
point
21,6
0.85
20,3
0.80
Pretravel: 2,54 mm [1.00 in] max.
Differential travel: 0,64 mm [0.025 in] max.
Overtravel: 4,83 mm [0.19 in] min.
Operating point: 44,1 mm ± 1,02
1.73 in ± 0.04
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A LS2F4K
DPDT B LS2F4L
HEAVY DUTY LIMIT SWITCHES
Actuators
56 www.honeywell.com/sensing
57
www.honeywell.com/sensing
Hazardous location switches
Honeywell explosion proof switches are designed specifically for use in
hazardous locations. To comply with explosion-proof requirements, the
flame path within the housing is designed to contain and cool the
escaping hot gases that otherwise could cause an explosion outside the
switch.
Switches are available with UL/CSA for North America. See information
below and product pages for details. In Europe, the usage is governed under
the European Directive on Equipment and Protective Systems Intended for
Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as
the ATEX Directive.
The BX, CX and GXE product families comply to the following ATEX Directive:
EExd IIC T6 Category II 2 GD
The 14CE100 product family complies to the following ATEX Directive:
EExd IIC T6 Category II 2 G
NEMA TYPE 7, CLASS I FLAMMABLE GASES OR VAPORS
Type 7 enclosures are for use indoors in locations classified as Class I,
Groups B, C, or D by the National Electrical Code.
Group B — (only switches so noted in the order guides include this listing).
Atmospheres containing hydrogen or manufactured gas.
Group C — atmospheres containing diethyl ether, ethylene, or cyclopropane.
Group D — Atmospheres containing gasoline, hexane, butane, naptha,
propane, acetone, toluene or isoprene.
Division 1
Locations in which hazardous agents are present under normal operating
conditions.
Division 2
Locations in which hazardous agents may be present only in case of
accidental rupture or breakdown.
All Honeywell listings covered in Division 1 are also covered in the same
groups in Division 2.
NEMA TYPE 9, CLASS II COMBUSTIBLE DUSTS
Type 9 enclosures are for use in indoor locations classified as Class II,
Groups E, F or G, as defined in the National Electrical Code.
Group E — Atmospheres containing metal dust.
Group F — Atmospheres containing carbon black, coal dust or coke dust.
Group G — Atmospheres containing flour, starch or grain dust.
ATEX EExd
Places with potentially
explosive
atmospheres, other
than mines susceptible
to fire damp
Gas
could be
present
Flameproof
enclosure
Atmosphere may
contain gases
from groups A, B
or C from table in
EN50014, Annex A
Maximum
surface
temperature of
85 °C [185 °F]
Areas in which an
explosion proof
atmosphere is likely to
occur
Dust
could be
present
EExd II c T6 Category II 2 G D
HAZARDOUS LOCATION SWITCHES
58 www.honeywell.com/sensing
Top pin plunger
M4 ground
screw
40,0 Max.
1,57
16,0 Max.
0.63
25,0
1.00
59,0
2.32 31,4
1.24
15,7 OP
0.62 1,8 PT
0.07
49,0 Max.
1.93
7,6
0.30
(2) Ø 5,1 (0.20)
Mounting holes
Ø 10,0 (0.39)
Stainless steel
plunger
"L"
CABLE LENGTH CAT. LISTING
1 m [3.3 ft] 14CE101-1
2 m [6.6 ft] 14CE101-2
3 m [9.9 ft] 14CE101-3
4 m [13.2 ft] 14CE101-4
5 m [16.5 ft] 14CE101-5
6 m [19.8 ft] 14CE101-6
10 m [33.0 ft] 14CE101-10
Boot sealed
1,80
(0.07) Ø 7,1 (0.28)
Stainless steel
plunger
Neoprene boot seal
Max.
PT
24,9
(0.98)
OP
CABLE LENGTH CAT. LISTING
1 m [3.3 ft] 14CE118-1
6 m [19.8 ft] 14CE118-6
10 m [33.0 ft] 14CE118-10
14CE100 Series
Miniature Enclosed,
Explosion Proof
Switches
The 14CE100 Series has been designed for use in explosive environments. It is approved to meet
the requirements of the Low Voltage directive and is CE marked. The prewired construction allows
for ease of installation where space is at a premium and external operating conditions can be
difficult.
Mechanical life: 10 million
Sealing: Standard IP65, NEMA 1, 3
Boot sealed IP67 , NEMA 1, 3, 4 12, 13
Operating temperature: 0 °C to 70 °C [32 °F to 158 °F]
Approvals: CE, PTB 98 ATEX 1064 X EExd IIC T6 Category II 2 G
AC14 D300
DC13 R300
Operating force (OF): 11,8 N max.
Pretravel (PT): 1,8 mm [0.71 in] max.
Overtravel (OT): 3,0 mm [0.118 in] min.
Differential travel (DT): 0,1mm [0.004 in] max.
Contacts: Standard Silver
-*GGold
Connection: Harmonised CENELEC 4 x 0,75 mm2 cable
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
GREEN/YELLOW
BLUE
1
BROWN
2
3
BLACK
S.P.D.T
Top roller plunger, parallel
M4 ground
screw
40,0 Max.
1,57
16,0 Max.
0.63
25,0
1.00
72,0
2,83 31,4
1.24
28,5 OP
1.11
1,8 PT
0.07
49,0 Max.
1.93
7,6
0.30
(2) Ø 5,1 (0.20)
Mounting holes
Ø 12,0 (0.47) x 5,0 (0.20)
Hardened steel roller
"L"
CABLE LENGTH CAT. LISTING
1 m [3.3 ft] 14CE102-1
3 m [9.9 ft] 14CE102-3
3 m [9.9 ft] Gold contacts 14CE102-3G
5 m [16.5 ft] 14CE102-5
6 m [19.8 ft] 14CE102-6
6 m [19.8 ft] Gold contacts 14CE102-6G
8 m [26.4 ft] 14CE102-8
12 m [39.6 ft] 14CE102-12
15 m [49.5 ft] 14CE102-15
Top roller plunger, perpendicular
M4 ground
screw
40,0 Max.
1,57
16,0 Max.
0.63
25,0
1.00
72,0
2,83 31,4
1.24
28,5 OP
1.11
1,8 PT
0.07
49,0 Max.
1.93
14,0
0.55
7,6
0.30
(2) Ø 5,1 (0.20)
Mounting holes
"L"
CABLE LENGTH CAT. LISTING
1 m [3.3 ft] 14CE103-1
3 m [9.9 ft] 14CE103-3
Actuators
ATEX
approved
HAZARDOUS LOCATION SWITCHES
59
www.honeywell.com/sensing
ATEX
approved
GXE Series
Explosion Proof
Limit Switches
The GXE Series explosion proof limit switches are designed specifically for use in hazardous
applications. The GXE enclosure is fully potted and has sealing protection of IP66/67 as per IEC/
EN 60529. The entire GXE Series complies with the European Directive on Equipment and
Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly
referred to as the ATEX Directive.
Mechanical life: 2 million
Sealing: IP66/67, EN 60529
Operating temperature: -20 °C to 75 °C [-4 °F to 167 °F]
Approvals: CE, EN 50014, EN 50018, EN 50281-1-1
KEMA 00 ATEX 2103 X EExd IIC T6 T85 Category II 2 GD
AC15
DC13
Contacts: Silver
Connection: 5 metre, HO5VV-F, 3 x 0,75 mm2 cable
Switching options:
SPDT Single Pole, Double Throw
Snap action contacts (1NC/1NO)
BLACK
BROWN
BLUE
OPTIONS
Side rotary roller lever
Overtravel min. (OT): 49°
Differential travel max. (DT):
Operating position max. (OP): 26°
CAT. LISTING
GXE51A1B
Top pin plunger
Overtravel min. (OT): 6,0 mm [0.0.236 in]
Differential travel max. (DT): 0,5mm [0.020
in]
Operating position max. (OP):2,0 mm [0.079
in]
CAT. LISTING
GXE51B
GXE Series
Operating force max. (OF): 16 N [3.6 lb]
Top roller plunger, parallel
Overtravel min. (OT): 6,0 mm [0.0.236 in]
Differential travel max. (DT): 0,5mm
[0.020 in]
Operating position max. (OP): 2,0 mm
[0.079 in]
CAT. LISTING
GXE51C
Actuators
HAZARDOUS LOCATION SWITCHES
60 www.honeywell.com/sensing
ATEX
approved
EX Series
Standard
Explosion
Proof
Switches
The EX Series features the smallest UL listed housings available for use in
hazardous locations. Flame paths within the housing are designed to
cool exploding gases below the kindling temperature before they reach
the explosive gases surrounding the housing.
Options available include single or double conduit connection.
These switches are not sealed against liquids and should not be used
where there will be liquid splash. If a weather sealed explosion proof
switch is required please select from the CX or LSX/BX series.
Sealing: NEMA 1, 7 (Class I, Division I, Groups C, D)
9, (Class II, Division I, Groups E, F, G)
Operating temperature: Standard
-40 °C to 71 °C [-40 °F to 160 °F]
High 100 hr @ 400 °F
Approvals: UL, CSA, KEMA 04ATEX2312X
Conduit: ½ in - 14NPT
Contacts: Silver
Electrical ratings:
A UL/CSA Rating: 15 A, 125, 250 or 480 Vac;
1
/
8
Hp, 125 Vac; ¼ Hp, 250 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc.
B UL/CSA Rating: 20 A, 125, 250 or 480 Vac;
10 A, 125 Vac “L”;
1 Hp, 125 Vac; 2 Hp, 250 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc.
C UL/CSA Rating: 10 A, 125 or 250 Vac;
0.3 A, 125 Vdc; 0.15 A, 250 Vdc
.
D UL/CSA Rating: 10 A, 125, 250 or 480 Vac;
½ A, 125 Vdc; ¼ A, 250 Vdc.
E UL Rating: 1 A, 125 Vac.
Switching options:
SPDT DPDT
Single Pole, Double Throw Double Pole, Double Throw
Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO)
Side rotary actuated switches
OPTIONS
No lever
Note: Levers are ordered separately
(see pages 71-73 for details)
Operating force max. (OF):
Electrical rating A 0,22 N m [31.25 in oz]
Electrical rating B 3,34 N to 8,90 N [0.75 lb to 2.0 lb]
Pretravel max. (PT): 5,56 mm [0.219 in] 8°
Overtravel max. (OT):
Electrical rating A 90°
Electrical rating B 25°
Differential travel max. (DT):
Electrical rating A 0,18 mm [0.007 in] 0.25°
Electrical rating B 0,3 mm [0.012 in] 4°
ACTUATION CONTACT ELECTRICAL RATING CAT. LISTING
CW SPDT A EX-AR20
CCW SPDT A EX-AR230
CW SPDT B EXA-AR20
Actuators
HAZARDOUS LOCATION SWITCHES
61
www.honeywell.com/sensing
Roller lever
Roller material: Bronze
Operating force max. (OF):
Electrical rating A
Clockwise (CW) 2,22 N to 5,56 N [0.5 lb to 1.25 lb]
Counter clockwise (CCW) 11,1 N [2.5 lb]
Electrical rating B 3,34 N to 8,90 N [0.75 lb to 2.0 lb]
Pretravel max. (PT):
Electrical rating A, B
Clockwise (CW) 5,56 mm [0.219 in] 8°
Counter clockwise (CCW) 1,65 mm [0.065 in] 3.5°
Overtravel max. (OT):
Electrical rating A
Clockwise (CW) 90°
Counter clockwise (CCW) 25°
Electrical rating B 25°
Differential travel max. (DT):
Electrical rating A 0,18 mm [0.007 in] 0.25°
Electrical rating B 0,3 mm [0.012 in] 4°
ACTUATION CONTACT ELECTRICAL RATING CAT. LISTING
CW SPDT A EX-AR
CCW SPDT A EX-AR30
CW/Class 1 Group B SPDT A EX-AR800
CCW/Class 1 Group B SPDT A EX-AR830
CW/High temperature SPDT A EX-AR400*
CW SPDT B EXA-AR
CW/No mounting bracket SPDT B EXA-AR62
CW/Nylon roller SPDT A EX-AR182
CW/No mounting bracket SPDT A EX-AR141
*No ATEX approval
CW or CCW actuation, no return spring, low
operating force
Operating force max. (OF): 0,56 N [2 oz]
ACTUATION CONTACT ELECTRICAL RATING CAT. LISTING
CW/CCW/No mounting bracket SPDT A EX-AR16
Maintained contact
Operating force max. (OF): 3,34 N [0.75 lb]
Pretravel max. (PT): 5,56 mm [0.219 in] 8°
Overtravel max. (OT): 90°
ACTUATION CONTACT ELECTRICAL RATING CAT. LISTING
CW SPDT A EX-XR3
DPDT, Preleaded with 0,91 m [3 ft] leadwire
Operating force max. (OF):
Clockwise (CW) 2,22 N to 6,67 N [0.5 lb to 1.5 lb]
Counter clockwise (CCW) 12,2 N [2.75 lb]
Pretravel max. (PT): 6,35 mm [0.250 in]
Overtravel max. (OT): 25°
Differential travel max. (DT): 2,77 mm [0.109 in] 4°
Sealing: NEMA Class 1 Group B
ACTUATION CONTACT ELECTRICAL RATING CAT. LISTING
CW DPDT C EXD-AR-3
CCW DPDT C EXD-AR30-3
Hermetically sealed
Operating force max. (OF):
Clockwise (CW) 2,22 N to 6,67 N [0.5 lb to 1.5 lb]
Counter clockwise (CCW) 11,1 N [2.5 lb]
Pretravel max. (PT):
Clockwise (CW) 5,56 mm [0.219 in] 8°
Counter clockwise (CCW) 1,65 N [0.065 in] 3.5°
Overtravel max. (OT): 25°
Differential travel max. (DT): 0,64 mm [0.025 in]
Sealing: NEMA Class 1 Group B
ACTUATION CONTACT ELECTRICAL RATING CAT. LISTING
CW/3,2 m [10.5 ft] leadwire SPDT E EXH-AR3
CCW/0,91 m [3 ft] leadwire SPDT E EXH-AR33
CW/0,91 m [3 ft] leadwire SPDT E EXH-AR7
2 Conduit openings
Operating force max. (OF):
Electrical rating A 2,22 N to 5,56 N [0.5 lb to 1.25 lb]
Electrical rating B 3,61 N to 8,90 N [0.8 lb to 2 lb]
Electrical rating C 2,22 N to 6,67 N [0.5 lb to 1.5 lb]
Pretravel max. (PT):
Electrical rating A, B 5,56 mm [0.219 in] 8°
Electrical rating C 6,35 mm [0.250 in]
Overtravel max. (OT):
Electrical rating A 90°
Electrical rating B, C 25°
Differential travel max. (DT):
Electrical rating A 0,18 mm [0.007 in] 0.25°
Electrical rating B 0,3 mm [0.012 in] 0.5°
Electrical rating C 2,77 mm [0.109 in] 4°
CONTACT ELECTRICAL RATING CAT. LISTING
DPDT C 4EX1-3
SPDT B 2EX1
SPDT A 1EX1
HAZARDOUS LOCATION SWITCHES
62 www.honeywell.com/sensing
EX Series
Side rotary actuated switches (continued)
Cross roller lever, rotated 90°
Operating force max. (OF): 2,22 N to 5,56 N [0.5 lb to 1.25 lb]
Pretravel max. (PT): 5,56 mm [0.219 in] 8°
Overtravel max. (OT 90°
Differential travel max. (DT): 0,18 mm [0.007 in] 0.25°
CONTACT ELECTRICAL RATING CAT. LISTING
CW SPDT A EX-CR
Rod lever
Operating force max. (OF): 0,56 N [2 oz]
Pretravel max. (PT): 18°
Overtravel min. (OT): 40°
CONTACT ELECTRICAL RATING CAT. LISTING
CW/No mounting bracket SPDT A EX-AR1613
Overtravel plunger actuated switches
OPTIONS
Top pin plunger
Operating force max. (OF):
Electrical rating A, C 13,34 N [3.0 lb]
Electrical rating B 8,90 N [2 lb]
Pretravel max. (PT):
Electrical rating A 1,98 mm [0.078 in]
Electrical rating B 1,27 mm [0.050 in]
Electrical rating C 3,96 mm [0.156 in]
Overtravel min. (OT):
Electrical rating A 4,78 mm [0.188 in]
Electrical rating B 3,18 mm [0.125 in]
Electrical rating C 3,48 mm [0.141 in]
Differential travel max. (DT):
Electrical rating A 0,10 mm [0.004 in]
Electrical rating B 0,23 mm [0.009 in]
Electrical rating C 1,52 mm [0.060 in]
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A EX-Q
No mounting bracket SPDT A EX-Q62
High temperature SPDT A EX-Q400*
Low OF SPDT B EXA-Q
*No ATEX approval
Sealing NEMA Class 1 Group B
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A EX-Q800
Preleaded with 0,91 m [3 ft] leadwire DPDT C EXD-Q-3
HAZARDOUS LOCATION SWITCHES
63
www.honeywell.com/sensing
Boot sealed
Operating force max. (OF):
Electrical rating D 13,34 N [3.0 lb]
Electrical rating B 15,57 N [3.5 lb]
Pretravel max. (PT):
Electrical rating D 1,98 mm [0.078 in]
Electrical rating B 2,77 mm [0.109 in]
Overtravel min. (OT):
Electrical rating D 4,78 mm [0.188 in]
Electrical rating B 3,18 mm [0.125 in]
Differential travel max. (DT):
Electrical rating D 0,10 mm [0.004 in]
Electrical rating B 0,23 mm [0.009 in]
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT D EX-N15
Class 1 Group B SPDT B EXA-N
Manually actuated
Operating force max. (OF): 11,1 N [2.5 lb]
CONTACT ELECTRICAL RATING CAT. LISTING
SPDT A EX-AR50
HAZARDOUS LOCATION SWITCHES
64 www.honeywell.com/sensing
CX Series
Weather Sealed
Explosion Proof
Switches
CX switches, as are the LSX/BX Series, are built especially for outdoor use in hazardous
atmospheres. These enclosures are constructed to withstand the pressure of an internal
explosion.
O-ring seals make the enclosure weatherproof but are outside of required flame paths so
explosion proof requirements are maintained.
As factory assembled, all basic switches operate on clockwise and counterclockwise rotation. The
actuating mechanism can be field adjusted for CW or CCW operation only.
Analog output, 4 mA to 20 mA, is available.
Basic switches operate nearly simultaneously in multiple switch devices.
Shafts of devices without shaft restoring force can be rotated through 360°.
Sealing: IP66, 67; NEMA 1, 3, 4, 4X, 6, 6P, 7, 9 and 13
UL listed Class I, Div. 1, Groups B (16CX, 24CX, 26CX, and 84CX only),
C and D; and Class II, Div. 1, Groups E, F and G
CSA certified Class I, Div. 1, Groups B (16CX, 24CX, 26CX, and 84CX only),
C and D; and Class II, Groups E, F and G
Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F]
Approvals: UL, CSA
CX-E only ATEX EExd IIC T6 Category II 2 GD
Housing: Aluminium
80CX Bronze
Conduit: ¾ in - 14NPT
Contacts: A, C, D Silver
F Gold
Electrical Ratings:
A UL/CSA Rating: L96 15 A, 120, 240 or 480 Vac, ind. and res
1/8 Hp, 120 Vac; ¼ Hp, 240 Vac
0.5 A, 125 Vdc, 0.25 A, 250 Vdc, res
C UL/CSA Rating: L59 10 A, 120 or 240 Vax, ind. and res
0.3 A, 125 Vdc, 0.15 A, 250 Vdc, res
D UL/CSA Rating: L22 1 A, 120 Vax, ind. and res
F UL/CSA Rating: L22 1 A, 125 Vac
G Analog Current Output (4 mA to 20 mA) 12.5 Vdc to 40 Vdc
Switching options:
SPDT DPDT
Single Pole, Double Throw Double Pole, Double Throw
Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO)
Analog position sensing specifications (Electrical rating “G”)
Current output: 4 mA to 20 mA
Voltage compliance range: 12.5 Vdc to 40 Vdc
Maximum load resistance: RL, Max., –V Supply - 12.5
20 mA
Current signal output: 4 mA to 20 mA
Span: Adjustable from 15° to 90° of angular rotation
Null: 4 mA position may be set at any angular position
Actuators
ATEX
approved
HAZARDOUS LOCATION SWITCHES
65
www.honeywell.com/sensing
Short housing
Standard housing
OPTIONS
HOUSING BASIC CONTACT ELECTRICAL SHAFT RESTORING CAT. LISTING
SIZE SWITCHES RATING FORCE TO CENTRE
Short BZ (2) SPDT A With 11CX2
Short BZ (2) SPDT A Without 11CX12
Short BZ (2) SPDT A With 11CX2E
Short BZ (2) SPDT A Without 11CX12E
Short BZ (2) SPDT F With 1172CX2
Short BZ (2) SPDT F Without 1172CX12
Standard BZ (4) SPDT A With 21CX4
Standard BZ (4) SPDT A Without 21CX14
UL listed for Class I, Group B (hydrogen atmospheres)
HOUSING BASIC CONTACT ELECTRICAL SHAFT RESTORING CAT. LISTING
SIZE SWITCHES RATING FORCE TO CENTRE
Standard DT (2) DPDT C With 24CX2
Standard DT (2) DPDT C Without 24CX12
Short HS (2) SPDT D With 16CX2
Short HS (2) SPDT D Without 16CX12
Standard HS (4) SPDT D With 26CX4
Analog output, 4 mA to 20 mA
HOUSING BASIC CONTACT ELECTRICAL SHAFT RESTORING CAT. LISTING
SIZE SWITCHES RATING FORCE TO CENTRE
Short None N/A G With 18CX0
Short None N/A G Without 18CX10
Short None N/A G Without 18CX10E
Standard BZ (2) SPDT A, G With 281CX2
Standard BZ (2) SPDT A, G Without 281CX12
Bronze housing for use in corrosive
environments
80CX switches have rugged bronze housings which are resistant to salt water
and other corrosive environments. They comply with the NEMA 4X
requirement for protection against corrosion, in addition to NEMA
enclosure standards met by other CX switches. O-ring seals make the
enclosure weather-proof, but are outside of required flame paths,
maintaining explosion-proof requirements.
HOUSING BASIC CONTACT ELECTRICAL SHAFT RESTORING CAT. LISTING
SIZE SWITCHES RATING FORCE TO CENTRE
Standard BZ (2) SPDT A With 81CX2
Standard BZ (4) SPDT A With 81CX4
Standard BZ (4) SPDT A Without 81CX14
Standard DT (2) DPDT C With 84CX2
Basic Switch Type BZ BA DT HS
Pretravel (max.)* 15° 15° 30° 30°
Differential Travel (max.) 10° 10° 25° 20°
Overtravel (min.)* 90° 90° 75° 75°
Operating Torque (max.) 11.1 in lb/1,25 N m
* May be modified in field to suit application requirements.
Note: Levers are ordered separately
(see pages 71-73 for details)
Operating characteristics
Notes:
Add the letter “A” to listings with side mounting holes tapped 5/16 (8).
Example: 11CX2A
Add the letter “B” to listings with thru mounting holes tapped 3/8-24 (4).
Example: 11CX2B
Add the letter “C” to listings for low temperature (-40 °C/°F) applications.
Example: 11CX2C
Add “D01” to specify a “direct-couple” listing with 3/8 in. dia by 3/4 in. long
flatted shaft.
Example: 11CX2-D01
Add the letter “E” to listings for European Atex approvals.
Example: 11CX2E
For Replacement Basic Switch Assemblies, change the first number in the
listing to “9”.
Example: 11CX2 becomes 91CX2
HAZARDOUS LOCATION SWITCHES
66 www.honeywell.com/sensing
LSX/BX Series
Weather sealed
explosion proof
switches
LSX/BX Series weather sealed, explosion proof limit switches are for use
either indoor or outdoors in hazardous atmospheres. They are completely
sealed and designed for use in explosive gas/dust environments.
LSX/BX products meet the sealing standards of NEMA 1, 3, 4, 6, 7, 9 and 13.
BX products are also sealed to IP67 standard and are ATEX approved (see
specifications below).
All heads are field adjustable at 90° increments. Heads with side rotary
actuators can be adjusted for clockwise and counter clockwise operation.
Sealing:
LSX NEMA 1, 3, 4, 6, 7 (Class 1, Division 1, Groups B, C, D),
9 (Class 2, Division 1, Groups E, F, G), 13
BX IP67, NEMA 1, 3, 4, 6, 7 (Class 1, Division 1, Groups B, C, D),
9 (Class 2, Division 1, Groups E, F, G), 13
Approvals:
LSX/BX UL, CSA*
BX only EExd IIC T6 category II 2 GD, SIRA 00ATEX 1037X
Contacts:
Electrical ratings A, B Silver
Electrical rating C Gold
Switching options:
SPDT DPDT
Single Pole, Double Throw Double Pole, Double Throw
Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO)
SPDT Double Break
DPDT Double Break
* Applies only to listings with ½ in NPT or ¾ in NPT
Electrical ratings
10 amps continuous carry. Circuits on any one pole must be the same
polarity.
ac Volts
Pilot duty: 600 Vac, 720 VA
Amps at 0.35 Power Factor
Vac Make Break
A 120 60 6
SPDT 240 30 3
NEMA 480 15 1.5
A600 600 12 1.2
B 120 30 3
DPDT 240 15 1.5
NEMA 480 7.5 0.75
B600 600 6 0.60
C 250 Vac or 60 Vdc, 0.050 amp max.
SPDT/DPDT
dc Volts
Pilot duty: 240 Vdc, 30 watts
Make and Break Amps
Vdc Inductive Resistive
A 120 0.25 0.8
SPDT 240 0.15 0.4
B 120 0.25 0.8
DPDT 240 0.15 0.4
C 250 Vac or 60 Vdc, 0.050 amp max.
SPDT/DPDT
Rotary actuated switches
Operating torque max.: Standard 0,45 N m [4.0 in lb]
Low 0,19 Nm [1.7 in lb]
Pretravel max. (PT): Standard 15°
Low
Overtravel min. (OT): Standard 60°
Low 66°
Differential travel max. (DT):
Standard SPDT
Standard DPDT 7°
Low SPDT 3°
Low DPDT
Note: Levers are ordered separately
(see pages 71-73 for details)
Actuators
BX
ATEX
approved
HAZARDOUS LOCATION SWITCHES
67
www.honeywell.com/sensing
OPTIONS
Side rotary
50,8
2.00
39,6
1.56 19,0
0.75
31,9
1.25 49,3
1.94
25,4
1.00
LSX
Operating temperature: -12 °C to 121 °C [10 °F to 250 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXA3K
SPDT 20 mm A LSX4A3K
SPDT ¾ in - 14NPT A LSXA4K
SPDT ½ in - 14NPT C LSXA3E
DPDT ¾ in - 14NPT B LSXA4L
DPDT 20 mm B LSX4A4L
DPDT ½ in - 14NPT B LSXA7L
Low DT SPDT ½ in - 14NPT A LSXP3K
BX (ATEX approved)
Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A BXA3K
SPDT 20 mm A BX4A3K
DPDT ¾ in - 14NPT B BXA4L
LSX
Operating temperature: -1 °C to 121 °C [30 °F to 250 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
Low DT/Low torque SPDT ½ in - 14NPT A LSXH3K
Low DT/Low torque DPDT ¾ in - 14NPT B LSXH4L
Low torque SPDT ½ in - 14NPT A LSXR3K
Low torque DPDT ¾ in - 14NPT B LSXR4L
BX (ATEX approved)
Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
Low torque SPDT ½ in - 14NPT A BXR3K
Low torque SPDT ½ in - 14NPT C BXR3E
Low torque DPDT ¾ in - 14NPT C BXR4S
Centre neutral
Operating torque max. : 0,45 N m [4.0 in lb]
Pretravel max. (PT): 18°
Overtravel min. (OT): 57°
Differential travel max. (DT): 10°
LSX
Operating temperature: -1 °C to 121 °C [30 °F to 250 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
DPDT ¾ in - 14NPT B LSXM4N
DPDT 20 mm B LSX4M4N
Maintained contact
Operating torque max.: 0,45 N m [4.0 in lb]
Pretravel max. (PT): 65°
Overtravel min. (OT): 20°
Differential travel max. (DT): SPDT 30°
DPDT 35°
LSX
Operating temperature: -1 °C to 121 °C [30 °F to 250 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
Maintained SPDT ½ in - 14NPT A LSXN3K
Maintained DPDT ¾ in - 14NPT B LSXN4L
Maintained DPDT ½ in - 14NPT B LSXN7L
BX (ATEX approved)
Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
Maintained SPDT ½ in - 14NPT A BXN3K
Maintained DPDT ¾ in - 14NPT B BXN4L
Top rotary
Operating torque max.: 0,28 N m [2.5 in lb]
Pretravel max. (PT): 25°
Overtravel min. (OT): 100°
Differential travel max. (DT): SPDT 10°
DPDT 12°
LSX
Operating temperature: -1 °C to 121 °C [30 °F to 250 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXB3K
DPDT ¾ in - 14NPT B LSXB4L
HAZARDOUS LOCATION SWITCHES
68 www.honeywell.com/sensing
LSX/BX Series (continued)
Plunger actuated switches
Top plungers
Operating force max. (OF): 17,79 N [4 lb]
Pretravel max. (PT): 1,78 mm [0.07 in]
Overtravel min. (OT): 4,83 mm [0.19 in]
Differential travel max. (DT):
SPDT 0,38 mm [0.015 in]
DPDT 0,51 mm [0.02 in]
OPTIONS
Top pin plunger
Operating point: 58,5 mm ± 0,76 mm
[2.305 in ± 0.03 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXC3K
SPDT 20 mm A LSX4C3K
DPDT ¾ in - 14NPT B LSXC4L
BX (ATEX approved)
Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT 20 mm A BX4C3K
DPDT ¾ in - 14NPT B BXC4L
DPDT 20 mm B BX4C4L
Top pin plunger, adjustable
21,6
(0.85)
7,9
(0.31)
Max.
operating point
72,0
(2,83)
Min.
operating point
65,7
(2,59)
Operating point: 65,66 mm to 72,01 mm
[2.585 in to 2.835 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXV3K
Top roller plunger
Head can be set at 90° increments for cam or slide actuation
Operating point: 68,6 mm ± 1.00 mm [2.700 in ± 0.04 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXD3K
SPDT 20 mm A LSX4D3K
DPDT ¾ in - 14NPT B LSXD4L
BX (ATEX approved)
Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT 20 mm A BX4D3K
BX
ATEX
approved
HAZARDOUS LOCATION SWITCHES
69
www.honeywell.com/sensing
Side plungers
Operating force max. (OF): 26,69 N [6 lb]
Pretravel max. (PT): 2,54 mm [0.10 in]
Overtravel min. (OT): 4,83 mm [0.19 in]
Differential travel max. (DT): 1,14 mm [0.045]
OPTIONS
Side pin plunger
50,8
2.00
39,6
1.56 19,0
0.75
49,3
1.94
25,4
1.00
Operating point: 33,0 mm [1.30 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXE3K
DPDT ¾ in - 14NPT B LSXE4L
Side roller plunger
Roller may be set in vertical or horizontal position for cam or slide
actuation
Operating point: 44,1 mm [1.735 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXF3K
BX (ATEX approved)
Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A BXF3K
Wobble actuated switches
OPTIONS
Plastic rod
Operating force max. (OF): 2,78 N [10 oz]
Pretravel max. (PT): 25,4 mm [1.0 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXJ3K-7A
DPDT ¾ in - 14NPT B LSXJ4L-7A
Cat whisker
Operating force max. (OF): 1,39 N [5 oz]
Pretravel max. (PT): 50,8 mm [2.0 in]
LSX
Operating temperature: -12 °C to 93 °C [10 °F to 200 °F][10 °F to 200
°F]
CONTACT CONDUIT ELECTRICAL RATING CAT. LISTING
SPDT ½ in - 14NPT A LSXK3K-8A
HAZARDOUS LOCATION SWITCHES
70 www.honeywell.com/sensing
71
www.honeywell.com/sensing
Levers
Separate levers must be ordered with side
rotary types. The table provides a cross
reference between product families and the
lever order/reference numbers. The following
pages describe the levers. Illustrations are for
reference only. Exact mounting drawings and
dimensions are available from your local sales
office or from the website below.
Levers lock in any position, 360° around the
shaft. Rollers may be mounted on the front or
back of the lever.
All levers are supplied with cap screws.
Explosion proof switches
Because of explosion proof requirements, only
nylon rollers or other non sparking material
should be selected. BX/LSX, CX and EX
plunger and cat whisker types are of non
sparking material. Do not mix or substitute.
Specification (unless stated
otherwise)
Lever radius/length: 1.5 in [38,1 mm]
Roller Diameter: 0.75 in [19,1 mm]
Roller Width: 0.25 in [6,35 mm]
-EX 0.312 in [7,92 mm]
Note:
Not all levers are compatible
with all switches
LEVERS
CAT. ROLLER LIMIT SWITCH SERIES EXPLOSION PROOF SERIES
LISTING MATERIAL GLA HDLS LS2 LS BX/LSX CX EX
6PA57 Aluminium
6PA63 Stainless steel
6PA69 Spring rod
6PA80 Steel
6PA82 Steel
6PA102 Nylon
6PA144 Ball bearing
GLZ51A Nylon
GLZ51B Steel
GLZ52A Nylon
GLZ52B Steel
GLZ54J Aluminium
GLZ55B Steel
LSZ51 N/A 
LSZ51A Nylon 
LSZ51B Steel 
LSZ51C Nylon 
LSZ51D Steel
LSZ51W Rubber
LSZ51Y Rubber
LSZ52 N/A
LSZ52A Nylon 
LSZ52B Steel
LSZ52C Nylon 
LSZ52D Steel 
LSZ52J Nylon 
LSZ52K Nylon 
LSZ52M Nylon 
LSZ52N Nylon 
LSZ52W Rubber
LSZ52Y Rubber
LSZ53A Nylon
LSZ53B Steel
LSZ53D Steel
LSZ53E Nylon 
LSZ53P Steel
LSZ53S Nylon 
LSZ53U Steel
LSZ54 N/A 
LSZ54M Aluminium 
LSZ54N Stainless steel
LSZ54R Spring wire
LSZ54V Cable
LSZ55 N/A 
LSZ55A Nylon 
LSZ55B Steel
LSZ55C Nylon 
LSZ55D Steel
LSZ55W Rubber
LSZ55Y Rubber
LSZ61 Nylatron
LSZ67AA Rubber
LSZ68 Delrin
6PA5-EX Bronze
6PA127-EX Nylon
6PA130-EX Bronze
6PA131-EX Bronze
6PA136-EX Aluminium
6PA138-EX Nylon
6PA142-EX Bronze
6PA204-EX Nylon
Stainless steel
levers
LS2Z51A Nylon 
LS2Z51B Steel 
LS2Z52A Nylon 
LS2Z52B Steel 
LS2Z54N Steel 
72 www.honeywell.com/sensing
OPTIONS
Standard fixed lever
MOUNTED ON CAT. LISTING
Without roller LSZ51*
Nylon roller Front LSZ51A*
Metal roller Front LSZ51B
Nylon roller Back LSZ51C*
Metal roller Back LSZ51D
Nylon roller Front GLZ51A
Metal roller Front GLZ51B
Bronze roller Front 6PA5-EX*
Nylon roller Front 6PA127-EX*
Ball bearing roller Front 6PA144
Offset fixed lever
MOUNTED ON CAT. LISTING
Without roller LSZ55*
Nylon roller Back LSZ55A*
Metal roller Back LSZ55B
Nylon roller Front LSZ55C*
Metal roller Front LSZ55D
Metal roller Front GLZ55B
Adjustable lever
Operating radius/length: 1.5 in to 3.5 in
[38,1 mm to 88,9 mm]
-EX 1.69 in to 3.0 in
[42,9 mm to 76,2 mm]
MOUNTED ON CAT. LISTING
Adjustable lever, without roller LSZ52
Nylon roller Back LSZ52A*
Metal roller Back LSZ52B
Nylon roller Front LSZ52C*
Metal roller Front LSZ52D
Nylon roller,
Ø 1.0 in [25,4] x 0.5 in [12,7 mm] Front LSZ52J*
Nylon roller, Ø 1.5 in [38,1] Front LSZ52K*
Nylon roller, Ø 2.0 in [50,8] Front LSZ52M*
Nylon roller, 0.5 in wide [12,7 mm] Front LSZ52N*
Nylon roller Back GLZ52A
Metal roller Back GLZ52B
Nylon roller,
Ø 1.0 in [25,4] x 0.5 in [12,7 mm] Front 6PA138-EX*
One way roller lever
RADIUS/LENGTH CAT. LISTING
Bronze roller, clockwise 1.56 in [39,6 mm] 6PA130-EX*
Bronze roller, counter clockwise1.56 in [39,6 mm] 6PA142-EX*
Perpendicular (cross) roller lever
RADIUS/LENGTH CAT. LISTING
Bronze roller 1.81 in [46,0
mm] 6PA131-EX*
Yoke lever
MOUNTED ON CAT. LISTING
Nylon roller Front/Back LSZ53A
Metal roller Front/Back LSZ53B
Metal roller Front/Front LSZ53D
Nylon roller Back/Front LSZ53E*
Metal roller Back/Back LSZ53P
Nylon roller Back/Back LSZ53S*
Metal roller Back/Front LSZ53U
Metal roller Front/Back 6PA80
Metal roller Front/Front 6PA82
Nylon roller Front/Front 6PA102
Adjustable rod
RADIUS/LENGTH CAT. LISTING
Hub only LSZ54*
Aluminium rod 5.5 in [139,7 mm] LSZ54M*
Stainless steel rod 13.0 in [330,2 mm] LSZ54N
Aluminium, spring only 12.0 in [305 mm] LSZ54R
Aluminium, flexible cable 4.8 in [122 mm] LSZ54V
Aluminium rod 7.9 in [200 mm] GLZ54J
Stainless steel rod 13.0 in [330,2 mm] 6PA63
Aluminium rod 5.3 in [134,1 mm] 6PA136-EX*
Adjustable rod, nylon roller
RADIUS/LENGTH CAT. LISTING
Aluminium rod, nylon roler 12.5 in [317,5 mm] 6PA204-EX*
Spring rod
RADIUS/LENGTH CAT. LISTING
Ø 0.25 in [6,35 mm] 12.0 in [305 mm] LSZ68
Ø 0.17 in [4,32 mm] 7.4 in [188 mm] 6PA69
LEVERS
Note: Not all levers are compatible with all switches
* denotes lever suitable for Explosion Proof Series switches
73
www.honeywell.com/sensing
NOTICE **
Large rubber rollers and conveyor roller arm
Because of the lever’s mass, the limit switch should be
mounted with the lever facing down. This will enable
gravity to help restore the switch to the free position.
Flexible loop
RADIUS/LENGTH CAT. LISTING
Flexible loop 6.0 in [152 mm] LSZ61
Hand operated button
CAT. LISTING
Ø 1.5 in [38,1 mm] 6PA57
**Large rubber roller, fixed
lever
CAT. LISTING
Ø 1.6 in X 0.50 in wide roller LSZ51W
[40,6 mm X 12,7 mm]
Ø 2 in X 0.50 in wide roller LSZ51Y
[50,8 mm X 12,7 mm]
**Large rubber roller, fixed offset
lever
CAT. LISTING
Ø 1.6 in X 0.50 in wide roller LSZ55W
[40,6 mm X 12,7 mm]
Ø 2 in X 0.50 in wide roller LSZ55Y
[50,8 mm X 12,7 mm]
**Large rubber roller, adjustable
lever
CAT. LISTING
Ø 1.6 in X 0.50 in wide roller LSZ52W
[40,6 mm X 12,7 mm]
Ø 2 in X 0.50 in wide roller LSZ52Y
[50,8 mm X 12,7 mm]
**Conveyor roller arm
Operating radius/length: 6.78 in [172,2 mm]
CAT. LISTING
Plastic roller, 1.5 in Ø X 3.8 in long LSZ67AA
[38,1 mm X 96,5 mm]
LEVERS
Stainless steel levers
Roller Diameter: 0.75 in [19,1 mm]
Roller Width: 0.25 in [6,35 mm]
OPTIONS
Standard fixed lever
Operating radius/length: 1.5 in [38,1 mm]
MOUNTED ON CAT. LISTING
Nylon roller Front LS2Z51A*
Stainless steel roller Front LS2Z51B
Adjustable lever
Operating radius/length: 1.5 in to 3.5 in
[38,1 mm to 88,9 mm]
MOUNTED ON CAT. LISTING
Nylon roller Back LS2Z52A*
Stainless steel roller Back LS2Z52B
Adjustable rod
Operating radius/length: 13 in [330,2 mm]
CAT. LISTING
LS2Z54N
Note: Not all levers are compatible with all switches
* denotes lever suitable for Explosion Proof Series switches
74 www.honeywell.com/sensing
MY2 Series
OPTIONS
Standard, PCB Terminal, DPDT
3,5
[0.14]
1,0
[0.04]
3,3
[0.13]
0,5
[0.02]
0,5
[0.02]
Max. 36, 0 [1.42] 6,0
[0.24]
Max. 21,5
[0.85]
6,3
[0.25]
Max. 28,0
[1.10]
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/5 amp SZR-MY2-1P-AC110-120V
220/240 Vac 250 Vac/5 amp SZR-MY2-1P-AC220V-240V
24 Vdc 125 Vdc/1 amp SZR-MY2-1P-DC24V
POWER RELAYS
SZR-MY
Series Power
Relay
Solder/Plug-In Terminal, DPDT
8 - O 1,2 [0.05] x 3 Holes
2,6
[0.10]
0,5
[0.02]
0,5
[0.02]
6,0
[0.24]
Max. 36,0 [1.42]
Max. 21,5
[0.85]
Max . 28 ,0 [1.10]
6,3
[0.25]
Standard
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/5 amp SZR-MY2-1-AC110-120V
220 Vac 250 Vac/5 amp SZR-MY2-1-AC220V
12 Vdc 125 Vdc/1 amp SZR-MY2-1-DC12V
24 Vdc 125 Vdc/1 amp SZR-MY2-1-DC24V
LED Indicator
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/5 amp SZR-MY2-N1-AC110-120V
220 Vac 250 Vac/5 amp SZR-MY2-N1-AC220V
12 Vdc 125 Vdc/1 amp SZR-MY2-N1-DC12V
24 Vdc 125 Vdc/1 amp SZR-MY2-N1-DC24V
Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/1 amp SZR-MY2-D1-DC24V
LED Indicator/Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/1 amp SZR-MY2-X1-DC24V
SZR-MY Series general-purpose power relays are designed for a wide
range of potential applications including power, as well as logic control,
for factory machines and control panels.
SZR-MY Series relays have a small package design for multiple
application needs. Relays are available in two configurations: DPDT with
a 5 A load and 4PDT with a 3 A load. One standard and three options
are available: LED indicator, internal surge protection diode, and LED
indicator/diode protection.
Current rating (SZR-MY2): 5 A
Current rating (SZR-MY4): 3 A
Contact resistance: 50 mOhm max.
Contact material: Fine silver
Agency approvals: UL, CE, CSA
Operate time: 20 ms max.
Release time: 20 ms max.
Ambient temperature: -25 °C to 75 °C [-13 °F to 167 °F]
Ambient humidity: 45% RH to 85% RH
Switching options: DPDT, 4PDT
75
www.honeywell.com/sensing
POWER RELAYS
Solder/Plug-In Terminal, 4PDT
14 - O 1.2 [0.05] x 3 Holes
0,5
[0.02]
Max. 36, 0 [1. 42] 6,0
[0.24]
Max. 21,5
[0.85]
Max. 28, 0
[1.10]
6,3
[0.25]
0,5
[0.02] 2,6
[0.10]
Standard
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/3 amp SZR-MY4-1-AC110-120V
220 Vac 250 Vac/3 amp SZR-MY4-1-AC220V
12 Vdc 125 Vdc/0.6 amp SZR-MY4-1-DC12V
24 Vdc 125 Vdc/0.6 amp SZR-MY4-1-DC24V
LED Indicator
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/3 amp SZR-MY4-N1-AC110-120V
220 Vac 250 Vac/3 amp SZR-MY4-N1-AC220V
12 Vdc 125 Vdc/0.6 amp SZR-MY4-N1-DC12V
24 Vdc 125 Vdc/0.6 amp SZR-MY4-N1-DC24V
Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/0.6 amp SZR-MY4-D1-DC24V
LED Indicator/Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/0.6 amp SZR-MY4-X1-DC24V
MY4 Series
OPTIONS
Standard, PCB Terminal, 4PDT
3,5
[0.14]
3,3
[0.13]
1,0
[0.04]
0,5
[0.02]
0,5
[0.02]
5,0
[0.20]
Max. 36,0 [1.42]
Max. 21,5
[0.85]
6,3
[0.25]
Max. 28,0
[1.10]
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/3 amp SZR-MY4-1P-AC110-120V
220/240 Vac 250 Vac/3 amp SZR-MY4-1P-AC220V-240V
24 Vdc 125 Vdc/0.6 amp SZR-MY4-1P-DC24V
76 www.honeywell.com/sensing
POWER RELAYS
SZR-LY Series Power Relay
SZR-LY Series general-purpose power relays are designed for a wide
range of potential applications including power, as well as logic control,
for factory machines and control panels.
SZR-LY Series relays break 10 A loads are often ideal for control panels
that require stable and reliable relays.
One standard and three options are available: LED indicator, internal
surge protection diode, and LED indicator/diode protection.
Current rating: 10 A
Contact resistance: 50 mOhm max.
Contact material: Silver cadium oxide
Agency approvals: UL, CE, CSA
Operating frequency: 18,000 operations/hour (mechanical)
1,800 operations/hour (electrical)
Operate time: 25 ms max.
Release time: 25 ms max.
Ambient temperature: -25 °C to 70 °C [-13 °F to 158 °F]
Ambient humidity: 45% RH to 85% RH
Switching options: DPDT, 4PDT
LY2 Series
OPTIONS
Standard, PCB Terminal, DPDT
0,5
[0.02]
2,0
[0.08]
1,0
[0.04] 4,5
[0.18]
Max. 36,0 [1.42] Max. 21,5 [0.85]
Max. 28,0 [1.10]
5,75
[0.23]
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/10 amp SZR-LY2-1P-AC110-120V
24 Vdc 125 Vdc/2 amp SZR-LY2-1P-DC24V
Solder/Plug-In Terminal, DPDT
Max. 36,0 [1.42]
0,5
[0.02]
5,0
[0.20]
3,0 [0.12]
6,4 [0.26] Max. 21,5
[0.85]
5,75
[0.23]
Max. 28,0 [1.10]
14 - O 3,0 [0.12]
Standard
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/10 amp SZR-LY2-1-AC110-120V
220 Vac 250 Vac/10 amp SZR-LY2-1-AC220V
12 Vdc 125 Vdc/2 amp SZR-LY2-1-DC12V
24 Vdc 125 Vdc/2 amp SZR-LY2-1-DC24V
LED Indicator
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/10 amp SZR-LY2-N1-AC110-120V
220 Vac 250 Vac/10 amp SZR-LY2-N1-AC220V
12 Vdc 125 Vdc/2 amp SZR-LY2-N1-DC12V
24 Vdc 125 Vdc/2 amp SZR-LY2-N1-DC24V
Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/2 amp SZR-LY2-D1-DC24V
LED Indicator/Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/ 2 amp SZR-LY2-X1-DC24V
77
www.honeywell.com/sensing
POWER RELAYS
Solder/Plug-In Terminal, 4PDT
14 - O 3.0 Holes
Max. 36,0 [1.42] 6,4 [0.25]
3,0
[0.12]
5,0
[0.20]
0,5
[0.02]
Max. 41,5 [1.63]
Max. 28,0 [1.10]
Standard
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/10 amp SZR-LY4-1-AC110-120V
220 Vac 250 Vac/10 amp SZR-LY4-1-AC220V
12 Vdc 125 Vdc/2 amp SZR-LY4-1-DC12V
24 Vdc 125 Vdc/2 amp SZR-LY4-1-DC24V
LED Indicator
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/10 amp SZR-LY4-N1-AC110-120V
220 Vac 250 Vac/10 amp SZR-LY4-N1-AC220V
12 Vdc 125 Vdc/2 amp SZR-LY4-N1-DC12V
24 Vdc 125 Vdc/2 amp SZR-LY4-N1-DC24V
Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/2 amp SZR-LY4-D1-DC24V
LED Indicator/Diode Protection
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
24 Vdc 125 Vdc/2 amp SZR-LY4-X1-DC24V
LY4 Series
OPTIONS
Standard, PCB Terminal, 4PDT
Max. 36, 0 [1.42]
1,0
[0.04] 4,5
[0.18]
2,0
[0.08]
0,5
[0.02]
Max. 41, 5 [1.63]
Max. 28,0 [1.10]
COIL INPUT VOLTAGE MAX. CONTACT RATING CAT. LISTING
110/120 Vac 250 Vac/10 amp SZR-LY4-1P-AC110-120V
220/240 Vac 250 Vac/10 amp SZR-LY4-1P-AC220V-240V
24 Vdc 125 Vdc/2 amp SZR-LY4-1P-DC24V
78 www.honeywell.com/sensing
25,0 [0.99]
18,0
[0.70]
15,6
[0.61]
45,0
[1.77]
35,2
[1.39]
3,9
[0.15]
6,0
[0.24]
4,2
[0.17]
62,0 [2.44]
30,0 [1.18]
26,0 [1.02]
3,0
[0.12]
62,0 ± 0,1
[2.44 ± .004]
2 - O 4,5 [0.18] Holes
2-M3 or 2-M4
Max. 61,0 [2.40]
26,0
[1.02]
MY2 Series Socket
TYPE POLES CAT. LISTING
Rail socket 2 SZX-SMF-08N
MY4 Series Socket
TYPE POLES CAT. LISTING
Rail socket 4 SZX-SMF-14N
30,0 [1.18 ]
26,0 [1. 02]
3,0
[0.12] 62,0 [2.44]
4,2
[0.17]
45,0 [1. 77]
15,6
[0.61]
35,2 [1. 39]
62,0 ± 0,1 [2.44 ± .004]
2 - O 4,5 [0.18] Holes
2- M 3 or 2-M4
25,0 [0. 99]
18,0
[0.70]
Max. 61,0 [2.40]
6,0
[0.24] 3,9
[0.15] 26,0
[1.02]
LY2 Series Socket
TYPE POLES CAT. LISTING
Rail socket 2 SZX-SLF-08N
LY4 Series Socket
TYPE POLES CAT. LISTING
Rail socket 4 SZX-SLF-14
2 - O 4,5 [0.18] Holes
2 - M4
25,0 ± 0,2
[0.99 ± .008]
19,0
[0.75]
2,5
[0.10]
14,5
[0.57]
25,0 [0.99]
4,2
[0.17]
30,0 [1.18]
26,0
[1.02]
47,0
[1.85]
67,0 [2.64]
22,0 [0.87]
8,0
[0.31]
Max. 61,0 [2 .4 0 ]
Max. 30,0 [1.18]
8,0
[0.31]
35,5 [1.40]
69,0 ± 0,3
[2.72 ± 0.01]
36,0 ± 0,2
[1.42 ± 0.008]
2-M4
3,4 [0.13]
14-M3.5x8
7,0
[0.28]
2 - O 6,0 [0.24]
4,5
[0.18]
68,0 [2.68]
Max. 78,5 [3.09 ]
Max. 45,5
[1.79]
Max. 66,0 [2.60]
POWER RELAYS
79
www.honeywell.com/sensing
SAFETY SWITCHES
Electromechanical Safety
Switches
Honeywell is a worldwide leader in advanced switching and sensing
technology - especially in the area of industrial safety. We offer both
electromechanical safety switches and electronic safety sensors as well as
safety control modules for safety applications in all categories of risk.
Our diverse product line can help customers meet all of their machine
safety needs.
Honeywell products meet or exceed European machine safety standards
and have been approved (CE, INRS) for use in Europe for more than 25
years. As North America moves toward harmonizing with global
standards, machine builders and users can confidently turn to Honeywell
for compliant machine safety solutions. Our products are designed to
meet all applicable OSHA and ANSI standards.
Refer to pages 6 and 7 for more information about degrees of
protection and electrical ratings.
Protective Guarding
Protective guarding around a dangerous machine can be achieved with
tamper-resistant safety switches. Safety switches incorporate positive
opening operation such that even a welded contact will be mechanically
broken and a stop signaled. These switches monitor the position of
moveable guards and doors, which are used to safeguard access to
equipment and provide protection from ejected pieces, chips, projectiles or
oil. These safeguards require a relatively low investment and can provide
reliable protection if they are regularly checked and maintained.
Cable Pull Switches
Cable-pull limit switches serve as a readily accessible means of
emergency stop for applications. These cable-pull devices are visible,
accessible and easy to use and are designed to immediately open the
emergency stop circuit when activated.
!
WARNING
IMPROPER INSTALLATION
Consult with local safety agencies and their requirements
when designing a machine-control link, interface and all
control elements that affect safety.
Strictly adhere to all installation instructions.
Failure to comply with these instructions could result in
death or serious injury.
80 www.honeywell.com/sensing
Selection Guide for Electromechanical Safety Switches
GSS
GKM GK
SAFETY SWITCHES
Dimensions Electrical
Rating
67 69,4 x 34,0 x 16,0
[2.73 x 1.34 x 0.63] Straight or 90°
Straight or 90°
AC15, DC13
A300 -25
[-13] 85
[185]
GSC
66 AC15, DC13
A300
GSD
66 AC15, DC13
A600
GSE
66 83,0 x 65,0 x 30,0
[3.27 x 2.56 x 1.18] AC15, DC13
A300
67 121,6 x 42,0 x 42,6
[4.79 x 1.65 x 1.68] Straight, 90°, Spring AC15, DC13
A600 -25
[-13] 85
[185]
67 149,0 x 110,0 x 48,8
[5.85 x 4.33 x 1.92] Straight, 90°, Spring AC15, DC13
A600 -25
[-13] 85
[185]
67 1, 4, 12,
13
1, 4, 12,
13
99,1 x 276,2 x 65,2
[3.9 x 10.87 x 2.57] Linear AC15, DC13
A600 -40
[-40] 85
[185]
67 165,1 x 79,8 x 325,9
[6.5 x 3.14 x 12.75] Left and/or Right AC15, DC13
A600 -40
[-40] 85
[185]
GKL/R1CPS GKM
Hinge
83,0 x 30,5 x 30,0
[3.27 x 1.2 x 1.18]
-25
[-13] 85
[185]
°C
[°F]
From
CSA
IEC
IP
Operating
Temperature
Housing Material
Series
Plastic Metal
Height x Width x Depth
mm
[in]
Approvals
2CPS
GSS
NEMA
(USA)
CE
UL
key
key
key
1, 4, 12,
13
1, 4, 12,
13
1, 4, 12,
1, 12, 13
13
1, 4, 6P,
12, 13
Sealing
1, 12, 13
Actuator
To
GK
CCC
GKN GKE
66
67
1, 12, 13
1, 12, 13
4 (indoor
use only)
Straight or 90°
key
Straight or 90°
key
AC15 A600,
DC13 Q300
AC15 A600,
DC13 Q300
-25
[-13] 85
[185]
-25
[-13] 85
[185]
90,0 x 40,0 x 33,0
[3.55 x 1.57 x 1.30]
92,2 x 30,5 x 30,5
[3.63 x 1.20 x 1.20]
81
www.honeywell.com/sensing
GKL/GKR
2CPS
1CPS
SAFETY SWITCHES
Termination
Make
Before
Break
1NC/
1NO 2NC/
2NO 1NC/
1NO 2NC/
2NO 1NC
1NC/
1NO
1NC/
1NO 2NC/
1NO 2NC/
2NO 3NC/
1NO 4NC
M12 or Cable
85
85
86
Conduit
Conduit
Conduit
Standard High intensity
multi-cluster LED 95
Conduit
Switching Options
Break Before Make
Slow Action
Snap Action
Page Number
Gold
Contacts
(Low
Energy
Options)
82
Daisy chain capability
87
89
93Integral LED option
Special Features
Conduit
2NC
1NC/
2NO
Conduit
Conduit
93
96
82 www.honeywell.com/sensing
SAFETY SWITCHES
GKM Series
Global Miniature
Safety Key
Operated Switch
Used alone as Category 1 safety components or, in conjunction with other safety switches and our
complete range of safety relays, it is possible to construct comprehensive protection schemes with
Category 2, 3 or 4 compliance.
The preleaded versions are designed to allow rapid fit, easy cable routing and function testing
which cut costs dramatically in OEM applications. Simple upgrade guarding solution for End User
applications.
Low energy basic switches are rated as follows:
Operating Voltage Ue 1 Vdc to 60 Vdc or 1 Vac to 125 Vac
Operating Current Ie 1 mA to 50 mA
Example of catalog listing using a low energy basic switch - GKMA19
Mechanical life: > 1 million
Sealing: IP66/67, EN 60529, NEMA 1, 12, 13
Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F]
Approvals: CE, UL, CSA
AC15 B300
DC13 Q300
Contacts: Silver
Low energy Gold plated
Switching options: Slow action contacts
1 Normally Closed/1 Normally Open, Break Before Make
1NC/1NO, BBM - GKMF 1NC/1NO, BBM, low energy - GKMA, B, C, D
3
3
4
4
2
21
1
1 Brown
4 Black
Blue 3
White 2
2 Normally Closed
2NC - GKMF 2NC, low energy - GKMA, B, C, D
3
3
4
4
2
21
1
1 Brown
4 Black
Blue 3
White 2
Electrical ratings: IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A) VA
Category
at rated operational voltage Ue rating
120 V 240 V 380 V 480 V 500 V 600 V Make Break
AC15 A600 6 3 1,9 1,5 1,4 1,2 7200 720
AC15 A300 6 3 - - - - 7200 720
AC15 B300 3 1.5 - - - - 3600 360
AC14 D300 0,6 0,3 - - - - 432 72
125 V 250 V
DC13 Q300 0,55 0,27 69 69
DC13 R300 0,22 0,1 28 28
12,8 /
0.504
1,6 /
0.058
17,2 /
0.67
37,4 /
1.47
2,3 /
0.69
22,0 /
0.866
34 max. /
0.34
32 max. /
1.26
16 max. /
0.63
Key
slot
Of key slot
10 max. /
0.30
90˚ - Key shown in optional
actuating positions Body style 'B'
0.366 0.177
2 X mounting holes
for M4 or #8 screws.
Counter bored both sides
08,3 X 4,5 deep.
83
www.honeywell.com/sensing
SAFETY SWITCHES
OPTIONS
Side exit cable
CABLE LENGTH CONTACT CAT. LISTING
1 m 2NC, low energy GKMA17
1 m 1NC/1NO, BBM, low energy GKMA19
2 m 1NC/1NO, BBM GKMA23
2 m 2NC GKMA26
2 m 2NC, low energy GKMA27
2 m 1NC/1NO, BBM, low energy GKMA29
3 m 1NC/1NO, BBM GKMA33
3 m 2NC GKMA36
3 m 2NC, low energy GKMA37
3 m 1NC/1NO, BBM, low energy GKMA39
Bottom exit cable
CABLE LENGTH CONTACT CAT. LISTING
1 m 1NC/1NO, BBM GKMB13
1 m 2NC GKMB16
1 m 2NC, low energy GKMB17
1 m 1NC/1NO, BBM, low energy GKMB19
2 m 1NC/1NO, BBM GKMB23
2 m 2NC GKMB26
2 m 2NC, low energy GKMB27
2 m 1NC/1NO, BBM, low energy GKMB29
3 m 1NC/1NO, BBM GKMB33
3 m 2NC GKMB36
3 m 2NC, low energy GKMB37
3 m 1NC/1NO, BBM, low energy GKMB39
Side exit M12 dc micro-change
connector
CONTACT CAT. LISTING
1NC/1NO, BBM GKMC03
2NC GKMC06
2NC, low energy GKMC07
1NC/1NO, BBM, low energy GKMC09
Bottom exit M12 dc micro-change
connector
CONTACT CAT. LISTING
1NC/1NO, BBM GKMD03
2NC, low energy GKMD07
1NC/1NO, BBM, low energy GKMD09
Dual exit M12 dc micro-change
connector
CONTACT CAT. LISTING
1NC/1NO, BBM GKMF03
2NC GKMF06
2NC, low energy GKMF07
1NC/1NO, BBM, low energy GKMF09
KEY STYLE
Straight key
3,5 /
0.138
2 + max. /
0.945
6,4 min. /
0.252
12,8 /
0.504
Face 'A'
2,5 /
0.093
2 holes for M4
or #8 screws
21,3 /
0.638
22 /
0.866
45 /
1.77
15 /
0.59
CAT. LISTING
Stainless steel GKZ51M
90° key
6,4 min. /
0.252
24 max. /
0.945
32 max. /
1.25
12,8 /
0.504
14 max. /
0.55
22 /
0.866
Face 'A'
0.083
2 holes for M4
or #8 screws with
45˚ C' SK X 2,1 deep
CAT. LISTING
Stainless steel GKZ52M
84 www.honeywell.com/sensing
GSS Series
Hinge Mount Safety
Limit Switch
The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative
solution to key operated interlocks and safety limit switches. When the access door is opened, a
follower pin (not supplied) slides down the slot in the actuator lever, forcing the actuator lever to
rotate and positively open the NC safety circuit to shut off the machine. Closing the access door
rotates the actuator lever to the reset position, closing the NC safety contacts.
The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offset-
mounted from the hinge point of the door. The tamper-resistant design and the positive opening
contacts provide an enhanced level of safety over the conventional spring-driven limit switches often
used to monitor door position.
Low Energy Switching
In today’s demanding age of low energy controls, electromechanical switches are frequently used to
interface directly with safety relays, PLCs and other low energy devices. To accommodate this
requirement GSS offers a new gold plated contact version of the standard basic switch. This
improves reliability of switching at low currents and voltages by protecting the contact surfaces from
contamination during operation or storage prior to use.
Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain
environmental conditions, e.g. in the presence of moisture.
Low energy basic switches are rated as follows:
Operating Voltage Ue1 Vdc to 60 Vdc or 1 Vac to 125 Vac
Operating Current Ie1 mA to 50 mA
Example of catalog listing using a low energy basic switch - GSCB33S2.
Switching options:
GSC/D GSE
Snap action contacts (1NC/1NO) Slow action contacts (4NC)
Zb
2221
14
13
11 12
21 22
31 32
4Y
41 42
Slow action contacts (1NC/1NO) BBM Slow action contacts (2NC/2NO) BBM
Zb
21
13
22
14
11 12
21 22
33 34
2Y, 2X
43 44
Slow action contacts (2NC) Slow action contacts (3NC/1NO) BBM
11
21
12
22
2Y
2221
11 12
3231
4443
3Y, 1X
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A) VA
Category
at rated operational voltage Ue rating
120 V 240 V 380 V 480 V 500 V 600 V Make Break
AC15 A600 6 3 1,9 1,5 1,4 1,2 7200 720
AC15 A300 6 3 - - - - 7200 720
AC15 B300 3 1.5 - - - - 3600 360
AC14 D300 0,6 0,3 - - - - 432 72
125 V 250 V
DC13 Q300 0,55 0,27 69 69
DC13 R300 0,22 0,1 28 28
Electrical ratings:
SAFETY SWITCHES
85
www.honeywell.com/sensing
GSC Metal body
GSD Plastic body
EN 50047
Safety Standard
24,75 /
0.97
14,5 /
0.57
30 /
1.18
conduit
thread
ø 23 /
ø 0.9
19,8 /
0.78
22 /
0.87
20 /
0.78
3 /
0.12
2,15 /
0.08
R
55 /
2.16
30,5 /
1.20
3,5 /
0.138
Mechanical life: up to 1 million
Sealing: IP 66
(GSC)
NEMA 1, 4, 12, 13
(GSD)
NEMA 1, 12, 13
Operating temperature: -25 °C to 85 °C
[-13 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
AC15 A300
DC13 Q300
UL, CSA
ACTUATED SWITCHES
Rotated 90° to the left
from center
70 /
2.76
45 /
1.77
104 /
4.09
GSC - Metal body
CONTACT CONDUIT CAT. LISTING
1NC/1NO ½ in NPT GSCA01S1
1NC/1NO, BBM ½ in NPT GSCA03S1
2NC ½ in NPT GSCA06S1
2NC, low energy 20 mm GSCC36S1
GSD - Plastic body
CONTACT CONDUIT CAT. LISTING
1NC/1NO, BBM ½ in NPT GSDA03S1
2NC ½ in NPT GSDA06S1
1NC/1NO, BBM PG 13,5 GSDB03S1
2NC PG 13,5 GSDB06S1
1NC/1NO 20 mm GSDC01S1
Rotated 90° either direction from
center
12,5 /
0.49
24,8 /
0.97
2 /
0.08
11,5 /
0.45
5,1 /
0.20
45 /
1.77
70 /
2.76
28 /
90 min. 90 min.
GSC - Metal body
CONTACT CONDUIT CAT. LISTING
1NC/1NO ½ in NPT GSCA01S2
1NC/1NO, BBM ½ in NPT GSCA03S2
2NC ½ in NPT GSCA06S2
2NC, low energy PG 13,5 GSCB36S2
GSD - Plastic body
CONTACT CONDUIT CAT. LISTING
1NC/1NO, BBM ½ in NPT GSDA03S2
2NC ½ in NPT GSDA06S2
1NC/1NO, BBM PG 13,5 GSDB03S2
2NC PG 13,5 GSDB06S2
1NC/1NO 20 mm GSDC01S2
Rotated 90° to the right
from center
180 MIN
GSC - Metal body
CONTACT CONDUIT CAT. LISTING
1NC/1NO ½ in NPT GSCA01S3
1NC/1NO, BBM ½ in NPT GSCA03S3
2NC ½ in NPT GSCA06S3
2NC, low energy PG 13,5 GSCB36S3
GSD - Plastic body
CONTACT CONDUIT CAT. LISTING
1NC/1NO, BBM ½ in NPT GSDA03S3
2NC ½ in NPT GSDA06S3
1NC/1NO, BBM PG 13,5 GSDB03S3
2NC PG 13,5 GSDB06S3
1NC/1NO 20 mm GSDC01S3
SAFETY SWITCHES
86 www.honeywell.com/sensing
GSE EN 50047
Compatible
Safety 3 Conduit Metal
Standard
conduit
thread
60 /
2.37
4 /
0.16
52 /
2.05
57 /
2.24
65 /
2.56
13,75 /
0.54
2,5 /
0.1
R2,15 /
0.08
3 /
0.12
20 /
0.79
22 /
0.87
40 /
1.57
42 /
1.65
23,8 /
0.94
ø 23 /
ø 0.9
30 /
1.18
12 /
0.47
12,5 /
0.49
24,75 /
0.97
Mechanical life: up to 1 million
Sealing: IP 66, NEMA/UL 1, 4, 12, 13
Operating temperature: -25 °C to 85 °C
[-13 °F to 185 °F]
Approvals: IEC/EN 60947-5-1
AC15 A300
DC13 Q300
UL, CSA
ACTUATED SWITCHES
Rotated 90° to the left
from center
70 /
2.76
45 /
1.77
104 /
4.09
CONTACT CONDUIT CAT. LISTING
2NC/2NO, BBM ½ in NPT GSEA44S1
3NC/1NO, BBM ½ in NPT GSEA46S1
4NC, low energy 20 mm GSEC41S1
Rotated 90° either direction from
center
12,5 /
0.49
24,8 /
0.97
2 /
0.08
11,5 /
0.45
5,1 /
0.20
45 /
1.77
70 /
2.76
28 /
90 min. 90 min.
CONTACT CONDUIT CAT. LISTING
2NC/2NO, BBM ½ in NPT GSEA44S2
Rotated 90° to the right
from center
180 MIN
CONTACT CONDUIT CAT. LISTING
2NC/2NO, BBM ½ in NPT GSEA44S3
SAFETY SWITCHES
87
www.honeywell.com/sensing
SAFETY SWITCHES
GK Series
Dual Entry Key
Operated Safety
Interlock Switch
The GK Series is designed specifically for use on machines where key removal brings the machine to
an immediate safe condition. It provides enhanced operator safety when added to hinged or sliding
guard doors, screens and protective covers on enclosures. The GK Series is especially well suited for
large door applications, typically in the automotive plant floor environment. Its heavy duty construction
withstands harsh industrial environments where rugged, long-term durability is required.
Nearly 1000 options are available in a simple to understand part number tree.
A safety lockout device is also available for use with the GK Series. The lockout device (GKZL2) is
specifically designed to prevent a key from being inserted either manually, or by the access door
being closed while maintenance personnel are working on the machine. When inserted, the lockout
device can accommodate up to four padlocks to prevent unauthorised removal of the device.
Mechanical life: up to 15 million
Sealing: IP 67, NEMA/UL type 1, 4, 12,13
Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F]
Approvals: CE, CSA, UL
AC15 A300/A600
DC13 Q300
Contacts: Silver
Low energy
Gold
Switching options:
Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO)
13
21
14
22
Zb
13 14
21 22
11
23
12
24
Slow action contacts (1NC/1NO), BBM Slow action contacts (2NC)
Zb
21
13
22
14
21
11
22
12
2Y
Slow action contacts (2NC/2NO), BBM Slow action contacts (3NC/1NO)
21 22
13 14
23 24
11 12
2y,2x
21 22
31 32
43 44
11 12
3y,1x
Slow action contacts (4NC)
21 22
31 32
41 42
11 12
4y
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A) VA
Category
at rated operational voltage Ue rating
120 V 240 V 380 V 480 V 500 V 600 V Make Break
AC15 A600 6 3 1,9 1,5 1,4 1,2 7200 720
AC15 A300 6 3 - - - - 7200 720
AC15 B300 3 1.5 - - - - 3600 360
AC14 D300 0,6 0,3 - - - - 432 72
125 V 250 V
DC13 Q300 0,55 0,27 69 69
DC13 R300 0,22 0,1 28 28
88 www.honeywell.com/sensing
Electrical ratings:
Head orientation
OPTIONS
Opening to front and top
9 /
0.35
Standard
CONDUIT CONTACT KEY CAT. LISTING
1/2 NPT 1NC/1NO 90° GKBA1L7
1/2 NPT 1NC/1NO Up-down GKBA1L8-F11*
1/2 NPT 1NC/1NO None GKBA1LX
1/2 NPT 4NC 90° GKBA10L7
1/2 NPT 2NC/2NO, BBM Straight GKBA14L6
1/2 NPT 2NC/2NO, BBM 90° GKBA14L7
1/2 NPT 3NC/1NO, BBM Straight GKBA16L6
1/2 NPT 3NC/1NO, BBM 90° GKBA16L7
1/2 NPT 2NC/NO Straight GKBA2L6
1/2 NPT 4NC, low energy None GKBA30LX
1/2 NPT 3NC/1NO, BBM, low energy None GKBA36LX
1/2 NPT 1NC/1NO, BBM Straight GKBA3L6
1/2 NPT 1NC/1NO, BBM 90° GKBA3L7
1/2 NPT 2NC None GKBA6LX
PG 13,5 2NC/2NO, BBM Straight GKBB14L6
PG 13,5 1NC/1NO, BBM 90° GKBB3L7
PG 13,5 2NC 90° GKBB6L7
20 mm 2NC/2NO, BBM 90° GKBC14L7
20 mm 1NC/1NO Straight GKBC1L6
20 mm 1NC/1NO 90° GKBC1L7
20 mm 1NC/1NO None GKBC1LX
20 mm 2NC/NO None GKBC2LX
20 mm 4NC, low energy None GKBC30LX
20 mm 3NC/1NO, BBM, low energy None GKBC36LX
20 mm 2NC None GKBC6LX
* fluorocarbon seal
Single LED indicator
CONDUIT CONTACT KEY CAT. LISTING
1/2 NPT 1NC/1NO Straight GKCA1L6
1/2 NPT 1NC/1NO 90° GKCA1L7
1/2 NPT 1NC/1NO None GKCA1LX
1/2 NPT 2NC None GKCA6LX
1/2 NPT 4NC Straight GKCA10L6
1/2 NPT 2NC/2NO, BBM Straight GKCA14L6
1/2 NPT 2NC/2NO, BBM 90° GKCA14L7
1/2 NPT 2NC/2NO, BBM Side-side GKCA14L9
1/2 NPT 4NC, low energy None GKCA30LX
1/2 NPT 3NC/1NO, BBM, low energy None GKCA36LX
20 mm 1NC/1NO None GKCC1LX
20 mm 2NC None GKCC6LX
20 mm 4NC, low energy None GKCC30LX
20 mm 3NC/1NO, BBM, low energy None GKCC36LX
Double LED indicator
CONDUIT CONTACT KEY CAT. LISTING
1/2 NPT 2NC/2NO, BBM 90° GKDA14L7
32 /
1.26
42,6 /
1.68
82 /
3.23
121,6 /
4.79
30 /
1.18
5,3 /
0.21
7,3 /
0.29
35 /
1.38
45,7
1.80
42 /
1.65
75,9 /
2.99
60 /
2.36
31 /
1.22
ø 5,3 /
0.21
Opening to right and top
8 /
0.32
Single LED indicator
CONDUIT CONTACT KEY CAT. LISTING
1/2 NPT 2NC/2NO, BBM straight GKCA14M6
Opening to left and top
22 /
0.87
Single LED indicator
CONDUIT CONTACT KEY CAT. LISTING
1/2 NPT 2NC/2NO, BBM Straight GKCA14P6
1/2 NPT 1NC/1NO 90° GKCA1P7
Double LED indicator
CONDUIT CONTACT KEY CAT. LISTING
1/2 NPT 2NC/2NO, BBM 90° GKDA14P7
SAFETY SWITCHES
GK Series (continued)
89
www.honeywell.com/sensing
SAFETY SWITCHES
GKL/GKR Series
Dual Entry Solenoid
Key Operated
Safety Interlock
Switch
The GKR (head to the right) and GKL (head to the left) products offer the user an unrivalled range
of standard options.
The GKR/GKL product is a key actuated device incorporating a key trapping mechanism. The
switch is used on machinery where instant stop and access to the machinery is either impossible
(due to the momentum of the machine) or impractical (due to tool or machine damage or
scrapped product if the current machine cycle is interrupted).
The switch incorporates an optional manual override feature which allows removal of the key for
emergency access.
Over 1000 options are available in a simple to understand part number tree.
A safety lockout device is also available for use with the GKR/GKL Series. The lockout device (GKZL2) is
specifically designed to prevent a key from being inserted either manually, or by the access door being
closed while maintenance personnel are working on the machine. When inserted, the lockout device
can accommodate up to four padlocks to prevent unauthorised removal of the device.
Mechanical life: up to 1 million
Sealing: IP 68, NEMA/UL type 1, 4, 6P, 12,13
Operating temperature: -25 °C to 40 °C [-13 °F to 104 °F]
Approvals: CE, CSA, UL
AC15 A300/A600
DC13 Q300
Contacts: Silver
Low energy Gold-plated
Switching options:
Snap Action
Type 11NC/1NO Direct Opening
Zb
2221
14
13
Slow Acting
Type 3 Type 14/15
1NC/1NO, Break before make (BBM) 2NC/2NO, Break before make (BBM)
Zb
2221
1413
11 12
21 22
33 34
2Y, 2X
43 44
2 Slow Acting
Type 36 Type 40
3NC/1NO, Break before make (BBM),low energy 4NC
2221
11 12
3231
4443
3Y, 1X
11 12
21 22
31 32 4Y
41 42
Type 44 Type 46
2NC/2NO, Break before make (BBM) 3NC/1NO, Break before make (BBM)
2Y,2X
43 44
2221
11 12
3433
43 44
31 32
2221
11 12
3Y,1X
90 www.honeywell.com/sensing
GKL/GKR Series (continued)
Key: Type 6 Straight
Type 9 Side - side, spring loaded
Type X No key
Latching mechanism: Type A Mechanical (solenoid unlock
with screwdriver)
Type B Mechanical (without override)
Type S Electrical (solenoid unlock with
screwdriver)
Solenoid voltage:
Type 2 24 Vdc
Type 4 120 Vac
Electrical ratings:
OPTIONS
Opening to front and top
9 /
0.35
Left
1/2 in - NPT buna-n seals
CONTACT KEY LATCHING SOLENOID CAT. LISTING
TYPE TYPE VOLTAGE
3 (1NC/1NO, BBM) None A 24 Vdc GKLE3LXA2
40 (4NC) None A 24 Vdc GKLE40LXA2
46 (3NC, BBM) None A 24 Vdc GKLE46LXA2
Right
1/2 in - NPT buna-n seals
CONTACT KEY LATCHING SOLENOID CAT. LISTING
TYPE TYPE VOLTAGE
40 (4NC) None A 24 Vdc GKRE40LXA2
46 (3NC, BBM) None A 24 Vdc GKRE46LXA2
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A) VA
Category
at rated operational voltage Ue rating
120 V 240 V 380 V 480 V 500 V 600 V Make Break
AC15 A600 6 3 1,9 1,5 1,4 1,2 7200 720
AC15 A300 6 3 - - - - 7200 720
AC15 B300 3 1.5 - - - - 3600 360
AC14 D300 0,6 0,3 - - - - 432 72
125 V 250 V
DC13 Q300 0,55 0,27 69 69
DC13 R300 0,22 0,1 28 28
32,5 /
1.28
33 /
1.30
20 /
0.79 43 /
1.69
48,8 /
1.92
110 /
4.33
100 /
3.94
19 /
0.75
65 /
2.56
75 /
2.95
110 /
4.33
100 /
3.94
31 /
1.22
43,7 /
1.72
105,3 /
4.13
2 x 5,3 /
0.21
2 x 7,3 /
0.29 2 x ø 5,3 /
0.21
SAFETY SWITCHES
91
www.honeywell.com/sensing
SAFETY SWITCHES
Opening to right and top
12 /
0.47
Right
1/2 in - NPT buna-n seals
CONTACT KEY LATCHING SOLENOID CAT. LISTING
TYPE TYPE VOLTAGE
3 (1NC/1NO, BBM) None A 24 Vdc GKRE3MXA2
3 (1NC/1NO, BBM) None A 120 Vac GKRE3MXA4
3 (1NC/1NO, BBM) None S 24 Vdc GKRE3MXS2
3 (1NC/1NO, BBM) None S 120 Vac GKRE3MXS4
36 (3NC/1NO, BBM, low energy) None A 24 Vdc GKRE36MXA2
36 (3NC/1NO, BBM, low energy) None A 120 Vac GKRE36MXA4
36 (3NC/1NO, BBM, low energy) None S 24 Vdc GKRE36MXS2
20 mm - buna-n seals
CONTACT KEY LATCHING SOLENOID CAT. LISTING
TYPE TYPE VOLTAGE
1 (1NC/1NO) None A 24 Vdc GKRG1MXA2
1 (1NC/1NO) None A 120 Vac GKRG1MXA4
1 (1NC/1NO) None S 24 Vdc GKRG1MXS2
1 (1NC/1NO) None S 120 Vac GKRG1MXS4
3 (1NC/1NO, BBM) None A 24 Vdc GKRG3MXA2
36 (3NC/1NO, BBM, low energy) None A 24 Vdc GKRG36MXA2
36 (3NC/1NO, BBM, low energy) None A 120 Vac GKRG36MXA4
36 (3NC/1NO, BBM, low energy) None S 24 Vdc GKRG36MXS2
36 (3NC/1NO, BBM, low energy) None S 120 Vac GKRG36MXS4
Opening to left and top
26 /
1.02
Left
1/2 in - NPT buna-n seals
CONTACT KEY LATCHING SOLENOID CAT. LISTING
TYPE TYPE VOLTAGE
3 (1NC/1NO, BBM) None A 24 Vdc GKLE3PXA2
3 (1NC/1NO, BBM) None A 120 Vac GKLE3PXA4
3 (1NC/1NO, BBM) None S 24 Vdc GKLE3PXS2
3 (1NC/1NO, BBM) None S 120 Vac GKLE3PXS4
36 (3NC/1NO, BBM, low energy) None A 24 Vdc GKLE36PXA2
36 (3NC/1NO, BBM, low energy) None A 120 Vac GKLE36PXA4
36 (3NC/1NO, BBM, low energy) None S 24 Vdc GKLE36PXS2
36 (3NC/1NO, BBM, low energy) None S 120 Vac GKLE36PXS4
20 mm - buna-n seals
CONTACT KEY LATCHING SOLENOID CAT. LISTING
TYPE TYPE VOLTAGE
1 (1NC/1NO) Non A 24 Vdc GKLG1PXA2
1 (1NC/1NO) None A 120 Vac GKLG1PXA4
1 (1NC/1NO) None S 24 Vdc GKLG1PXS2
1 (1NC/1NO) None S 120 Vac GKLG1PXS4
3 (1NC/1NO, BBM) None S 24 Vdc GKLG3PXS2
36 (3NC/1NO, BBM, low energy) None A 24 Vdc GKLG36PXA2
36 (3NC/1NO, BBM, low energy) None A 120 Vac GKLG36PXA4
36 (3NC/1NO, BBM, low energy) None S 24 Vdc GKLG36PXS2
36 (3NC/1NO, BBM, low energy) None S 120 Vac GKLG36PXS4
44 (2NC/2NO, BBM) None B 24 Vdc GKLG44PXB2
92 www.honeywell.com/sensing
Keys for GK and
GKL/GKR switches
Straight key
15 /
0.59
8,5 /
0.33
20 /
0.79
49,8 /
1.96
77 /
3.03
14 /
0.55
3 /
0.12
0.21
2x ø 5,3 /
CAT. LISTING
GKZ56
90° key
8,5 /
0.33
49,8 /
1.96
14 /
0.55
40 /
1.57
52 /
2.05
0.21
2 x ø 5,3 /
CAT. LISTING
GKZ57
Spring-loaded key: up/down
40 /
1.57
30 /
1.18
18,5 /
0.73
13,5 /
0.53
14 /
0.55
84,9 /
3.34
8,5 /
0.33
17,8 /
0.70
0.21
2 X ø 5,3 /
CAT. LISTING
GKZ58
Spring-loaded key: left/right
8,5 /
0.33
14 /
0.55
84,9 /
3.34
20,5 /
0.81
13,5 /
0.53
18,5 /
0.73
30 /
1.18
40 /
1.57
0.21
2 X ø 5,3 /
CAT. LISTING
GKZ59
Locking slider bolt
with actuating key
3x HOLE PROVIDED
FOR LOCKOUT
19,0 /
.75
41,81 ±,76 /
1.646 ±.030
14,0 /
.55
7,0 ±,7 /
.28 ±.03
37,10 ±1,52 /
1.460 ±.060 26,77 ±1,52 /
1.054 ±.060
115,87 /
4.562 140,0 ±,7 /
5.51 ±.03
4x ø 5,1 /
.20 4,93 /
.194
12,04 /
.474
36,8 /
1.45
26,97 /
1.062
CAT. LISTING
0°key rotation GKZ71
CAT. LISTING
90° key rotation GKZ72
CAT. LISTING
180° key rotation GKZ73
CAT. LISTING
270° key rotation GKZ74
SAFETY SWITCHES
93
www.honeywell.com/sensing
GKE Series Dual
Entry Safety
Interlock Switch
The GKE Series safety key-operated switch provides enhanced reliability for safety hard-guarding
applications in a compact, cost-effective package.
Mechanical life: 1 million
Sealing: IP 66, NEMA 1, 12,13
Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F]
Approvals: cULus, CE
AC15 A500/A600
DC13 Q300
Switching options:
Switch Code 01: 1NC/1NO
Switch Code 03: 1NC/1NO (BBM)
Switch Code 06: 2NC
SAFETY SWITCHES
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A)
Category
at rated operational voltage Ue
24V 120 V 240 V 380 V 480 V 500 V 600 V
AC15 A500 6 3 1,9 1,5 1,4
AC15 A600 6 3 1,9 1,5 1,4 1,2
DC13 Q300 2,8 0,55 0,27
11
21
12
22
2Y
Zb
13
21
14
22
Zb
13
21
14
22
94 www.honeywell.com/sensing
OPTIONS
Dual Entry, Key Operated
1/2 in NPT conduit
CONTACT TYPE SWITCH CODE CAT. LISTING
1NC/1NO 01 GKEA1LX
1NC/1NO BBM 01 GKEC1LX
2NC 03 GKEA3LX
M20 x 1,5 conduit
CONTACT TYPE SWITCH CODE CAT. LISTING
1NC/1NO 03 GKEC3LX
1NC/1NO BBM 06 GKEA6LX
2NC 06 GKEC6LX
SAFETY SWITCHES
Head Code L
Head Code M
Head Code N
Head Code P
95
www.honeywell.com/sensing
GKZ51M Key and Mounting
CAT. LISTING
Straight key GKZ51M
GKZ52M Key and Mounting
CAT. LISTING
90 degree key GKZ52M
SAFETY SWITCHES
96 www.honeywell.com/sensing
SAFETY SWITCHES
GKN Safety Key
Operated Switch
The GKN Series safety interlock switches provide enhanced reliability in a compact, cost-effective
package size. A black plastic snap fit cover is provided to plug the unused key entry window.
Straight and 90 degree actuator keys are available seperately. The GKN Series conforms to IEC
60947-5-1 and carries cULus and CE approvals.
Mechanical life: 1 million
Sealing: IP 67, NEMA 1, 12,13, 4 (indoor use only)
Operating temperature: -25 °C to 85 °C [-13 °F to 185 °F]
Approvals: cULus, CE
Switching options:
1NC/1NO MBB
1NC/1NO BBM
2NC
2NC/1NO MBB
1NC/2NO MBB
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A)
Category
at rated operational voltage Ue
120 V 125V 240 V 600 V
AC15 A600 6 3 1,2
DC13 Q300 0,55 0,27
97
www.honeywell.com/sensing
SAFETY SWITCHES
OPTIONS
Dual Entry, Key Operated
M20 x 1,5 conduit
CONTACT TYPE CONDUIT OPENINGS CAT. LISTING
1NC/1NO BBM 3 GKNC3L
1NC/1NO MBB 3 GKNC4L
2NC/1NO MBB 2 GKNC12l
1NC/2NO MBB 2 GKNC33L
2NC 3 GKNC6L
GKZB1
CAT. LISTING
Straight stainless steel key GKZB1
GKZB2
CAT. LISTING
Straight thermoplastic key GKZB2
GKZB6
CAT. LISTING
Flexible key GKZB6
98 www.honeywell.com/sensing
99
www.honeywell.com/sensing
SAFETY SWITCHES
CPS Series
Cable Pull Safety
Switch
CPS Series Cable Pull Safety Switches provide a readily accessible emergency stop signal. This is a
cost-effective means compared to using multiple emergency stop push-buttons. (Cable Pull Safety
Switches are not, however, to be used as a means of personnel safeguarding. They may be used to
prevent further injury or damage to equipment when used for emergency stop signaling.)
The CPS Series Cable Pull Safety switch is designed to provide emergency stop protection for
exposed conveyor and assembly lines. The internal mechanism latches on both slackened cable
(push) and pulled cable. This capability also enhances productivity by eliminating nuisance stops due
to variations in temperature, stretch of cable over time, and other application variables.
The 1CPS is intended for use in applications where the cable span is 76 m [250 ft] or shorter. It is a
potential economical solution for shorter runs or zone protection typical to automated systems. The
2CPS series is intended for use in very long cable runs of 152 m [500 ft] or shorter, such as long
conveyor lines found in warehouses.
The CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC;
Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety
function; IEC/EN 60947-1; IEC/EN 60947-5-1; IEC/EN 60947-5-5.
Mechanical life: 1 000 000
Sealing: IP67, NEMA 1, 4, 12,13
Operating temperature: 1CPS -40 °C to 80 °C [-40 °F to 176 °F]
2CPS -40 °C to 80 °C [-40 °F to 176 °F]
Approvals: AC15 A300
DC13 Q300
1CPS UL, CSA
2CPS UL, CSA
Contacts: 1CPS Silver
1CPS, Low energy Gold plated
2CPS Gold plate over silver
Switching options:
1CPS 2CPS
1NC/1NO
2221
1413
N/A
2NC/2NO
2221
1413
2221
1413
2221
1413
2221
1413
3NC/1NO
2221
1413 2221
11 12 2221
1413 2221
11 12
4NC
12
2221
11 12
2221
11 12
2221
11 12
2221
11
2CPS contact block mounting: 1 To housing
2 Removable with heavy duty
terminals
1
I
2
I
1CPS indicator Light Code: No letter No indicator provided
A 24 Vdc red LED
B 120 Vac red LED
2CPS indicator Light Code: No letter No indicator provided
A 24 Vdc red multi-cluster LED
B 120 Vac red multi-cluster LED
100 www.honeywell.com/sensing
CPS Series (continued)
OPTIONS
Cable maintained
1/2 in NPT
CONTACT INDICATOR CAT. LISTING
1NC/1NO None 1CPSA1
1NC/1NO 24 V 1CPSA1A
1NC/1NO 120 V 1CPSA1B
2NC/2NO None 1CPSA2
2NC/2NO 24 V 1CPSA2A
2NC/2NO 120 V 1CPSA2B
3NC/1NO None 1CPSA3
3NC/1NO 24 V 1CPSA3A
3NC/1NO 120 V 1CPSA3B
4NC None 1CPSA4
1NC/1NO, low energy None 1CPSA5
2NC/2NO, low energy None 1CPSA6
2NC/2NO, low energy 24 V 1CPSA6A
2NC/2NO, low energy 120 V 1CPSA6B
3NC/1NO, low energy None 1CPSA7
4NC, low energy None 1CPSA8
12,7
[0.5]
117,42
[4.623]
50,8
[2.1]
172,72
[6.8] 152,4
[6.0] 81,28
[3.2]
6,35
[0.25]
99,06
[3.9]
1CPS
Cable Pull
Switch
TENSIONED
SLACK
RUN
RESET
OFF
4X Ø 7,11
Ø 0.28
88,9
[3.5]
76,2
[3.0]
33,02
[1.3]
65,20
[2.567]56,79
[2.236] 50,83
[2.001]
2X 26,67
[1.050]
3X 25,4
[1.0] 25,4
[1.00] 25,4
[1.00]
B
CD
A
A Fully extended
B Optional indicator
C Conduit thread (3 total)
D Mounting pad (4 total)
1CPS
SAFETY SWITCHES
20 mm
CONTACT INDICATOR CAT. LISTING
1NC/1NO None 1CPSC1
1NC/1NO 24 V 1CPSC1A
2NC/2NO None 1CPSC2
2NC/2NO 24 V 1CPSC2A
2NC/2NO 120 V 1CPSC2B
3NC/1NO None 1CPSC3
3NC/1NO 24 V 1CPSC3A
4NC None 1CPSC4
1NC/1NO, low energy None 1CPSC5
2NC/2NO, low energy None 1CPSC6
2NC/2NO, low energy 24 V 1CPSC6A
3NC/1NO, low energy None 1CPSC7
4NC, low energy None 1CPSC8
101
www.honeywell.com/sensing
SAFETY SWITCHES
Cable maintained both sides
1/2 in NPT
CONTACT CONTACT BLOCK INDICATOR CAT. LISTING
MOUNTING
2NC/2NO 1 None 2CPSA1A1
2NC/2NO 1 24 Vdc 2CPSA1A1A
2NC/2NO 1 120 Vac 2CPSA1A1B
3NC/1NO 1 None 2CPSA1B1
3NC/1NO 1 24 Vdc 2CPSA1B1A
3NC/1NO 1 120 Vac 2CPSA1B1B
2NC/2NO 2 None 2CPSA2A1
2NC/2NO 2 24 Vdc 2CPSA2A1A
2NC/2NO 2 120 Vac 2CPSA2A1B
3NC/1NO 2 None 2CPSA2B1
3NC/1NO 2 24 Vdc 2CPSA2B1A
3NC/1NO 2 120 Vac 2CPSA2B1B
20 mm
CONTACT CONTACT BLOCK INDICATOR CAT. LISTING
MOUNTING
2NC/2NO 1 None 2CPSC1A1
2NC/2NO 1 24 Vdc 2CPSC1A1A
4NC 1 24 Vdc 2CPSC1D1A
OFF
RUN
40,4
(1.60)
67,8
(2.63)
325,9
(12.75)
152,4
(6.00)
152,4
(6.00)
12,7
(0.50)
TENSIONED
SLACK
TENSIONED
SLACK
57,2
(2.25)
139,7
(5.50)
79,8
(3.14) 92,9
(3.66)
12,7
(0.50)
21,1
(0.75)
34,9
(1.38)
104,8
(4.13)
52,1
(2.05)
81,3
(3.20)
18,3
(0.72)
2X
2X
2X 6,9
(0.27)
2X 8,9
(0.35)
2X 31,75
(1.25)
2X 6,9
(0.27)
3X 21,5
(0.85)
2X
OFF
RUN
244,6
(9.63)
TENSIONED
SLACK
TENSIONED
SLACK
A
A
B
C
C
D
D
6,4
(0.25)
40,5
(1.60)
A Fully extended
B Optional indicator
C Conduit thread (3 total)
D Mounting pad (4 total)
2CPS
No actuation right side, cable maintained left side
1/2 in NPT
CONTACT CONTACT BLOCK INDICATOR CAT. LISTING
MOUNTING
2NC/2NO 1 None 2CPSA1A2
2NC/2NO 1 24 Vdc 2CPSA1A2A
2NC/2NO 1 120 Vac 2CPSA1A2B
3NC/1NO 1 None 2CPSA1B2
3NC/1NO 1 24 Vdc 2CPSA1B2A
3NC/1NO 1 120 Vac 2CPSA1B2B
2NC/2NO 2 None 2CPSA2A2
2NC/2NO 2 24 Vdc 2CPSA2A2A
2NC/2NO 2 120 Vac 2CPSA2A2B
20 mm
CONTACT CONTACT BLOCK INDICATOR CAT. LISTING
MOUNTING
2NC/2NO 1 None 2CPSC1A2
2NC/2NO 1 24 Vdc 2CPSC1A2A
No actuation left side, cable maintained right side
1/2 in NPT
CONTACT CONTACT BLOCK INDICATOR CAT. LISTING
MOUNTING
2NC/2NO 1 None 2CPSA1A3
2NC/2NO 1 24 Vdc 2CPSA1A3A
2NC/2NO 1 120 Vac 2CPSA1A3B
3NC/1NO 1 None 2CPSA1B3
3NC/1NO 1 24 Vdc 2CPSA1B3A
3NC/1NO 1 120 Vac 2CPSA1B3B
2NC/2NO 2 None 2CPSA2A3
2NC/2NO 2 24 Vdc 2CPSA2A3A
2NC/2NO 2 120 Vac 2CPSA2A3B
20 mm
CONTACT CONTACT BLOCK INDICATOR CAT. LISTING
MOUNTING
2NC/2NO 1 None 2CPSC1A3
2NC/2NO 1 24 Vdc 2CPSC1A3A
102 www.honeywell.com/sensing
CPS Series (continued)
Hardware packets (order separately)
CPS LED
31,75
[1.25]
A
BC
D
71,88 ±2,54
[2.83 ±0.10]
207,01 ±1,27
[8.15 ±0.05] 227,33 ±12,7
[8.95 ±0.50]
11,43
[0.45]
CPS Bracket
SAFETY SWITCHES
ACCESSORY CAT. LISTING
Cable - 7,6 m [25 ft] length CLSZC1
Cable - 15,2 m [50 ft] length CLSZC2
Cable - 30,5 m [100 ft] length CLSZC3
Cable - 45,7 m [150 ft] length CLSZC4
Cable - 61 m [200 ft] length CLSZC5
Cable - 76,2 m [250 ft] length CLSZC7
(2) Thimbles CLSZTC
(2) Low-profile Duplex Cable Clamps
ACCESSORY CAT. LISTING
(1) Draw-bar Endspring CPSZ1S
(1) J-hook Turnbuckle with Lock Nuts CPSZK1
(2) Thimbles
(2) Low-profile Duplex Cable Clamps
(16) Sets of Cable Supports ((16) 1/4-20 Eye Bolts,
(32) 1/4-20 Nuts, (32) Flat Washers, (16) Lock Washers)
Multicluster LED Accessory - 24 Vdc (conduit mount) CPSLED24
Multicluster LED Accessory - 120 Vdc (conduit mount) CPSLED120
Mounting bracket (to be used with 1CPS or 2CPS) CPS-BRACKET
J-hook turnbuckle with lock nuts (included with 2CPS) CPSZTB
103
www.honeywell.com/sensing
These listings include standard size basics, miniature and subminiature
switches. The precision snap-action mechanisms are offered with a wide
variety of actuators and operating characteristics. Basic switches are often
ideal for applications requiring compactness, light weight, accurate
repeatability and long life.
They are best used for presence/absence detection where physical contact
with object is permissible. Very economical.
Basic Switches
BASIC SWITCHES
Overtravel plunger (standard)
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A Screw BZ-2RD-A2
20 A Screw BA-2RB-A2
Panel mount overtravel plunger
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A Screw BZ-2RQ1-A2
20 A Screw BA-2RQ1-A2
BZ/BA/BM/BE Series Basic Switches
BZ/BA/BM/BE Series standard basic switches may be used for simple or
precision on/off application needs.
As well as the catalogue listings presented here, we offer other versions with
higher temperature ratings, different termination options, different electrical
ratings and Single Pole, Single Throw (SPST) circuitry. Refer to our Web site
for details.
Voltage: 250 Vac
Electrical rating: up to 25 A
Operating temperature: -55 °C to 85 °C [-67 ° F to 185 °F]
Termination: Screw
Contact type: Silver
Approvals: CE, CSA, UL, ENEC
Switching options: Single pole, double throw (SPDT)
OPTIONS
Note: BA/BE plunger position distance from mounting hole = 19 mm
[0.75 in]
Top pin plunger
Approvals: BE-2R-A4 CSA, UL
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A Solder BZ-R
15 A Screw BZ-R-A2
15 A Solder BZ-R169
15 A Screw BZ-2R-A2
25 A Screw BE-2R-A4
104 www.honeywell.com/sensing
BASIC SWITCHES BASIC SWITCHES
Overtravel plunger (splash resistant)
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A Screw BZ-2RDS-A2
15 A (Stainless steel spring) Screw BZ-2RDS-A2S
Overtravel roller plunger
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A Screw BZ-2RQ18-A2
Overtravel roller plunger, perpendicular
ELECTRICAL RATING APPROVALS CAT. LISTING
15 A Screw BZ-2RQ181-A2
Straight lever
ELECTRICAL RATING TERMINATION LEVER RADIUS CAT. LISTING
20 A Screw 63,5 mm [2.5 in] BA-2RV-A2
15 A Screw 63,5 mm [2.5 in] BZ-2RW80-A2
15 A Screw 152,4 mm [6.0 in] BZ-2RW863-A2
Roller lever
ELECTRICAL RATING TERMINATION LEVER RADIUS CAT. LISTING
15 A Screw 26,67 mm [1.05 in] BZ-2RW822-A2
15 A Solder 26,67 mm [1.05 in] BZ-2RW822
15 A (Splash resistant) Screw 26,67 mm [1.05 in] BZ-2RW8225551-A2
15 A Screw One way, 32,0 mm [1.26 in] BZ-2RW826-A2
15 A Screw 48,3 mm [1.9 in] BZ-2RW82-A2
BZ/BA/BM/BE Series (continued)
105
www.honeywell.com/sensing
BASIC SWITCHES
DT Series Basic Switches
DT Series standard basic switches consist of two independent single-pole
double throw circuits in one housing actuated by one actuator. The terminals
are separated by a non-conductive shield to reduce shorting.
Voltage: 250 Vac
Electrical rating: 10 A
Operating temperature: -55 °C to 85 °C [-67 ° F to 185 °F]
Termination: Screw
Contact type: Silver
Approvals: CSA, UL
Switching options: Double pole, double throw (DPDT)
Top pin plunger
ELECTRICAL RATING TERMINATION CAT. LISTING
10 A Screw DT-2R-A7
Basic Switch Accessories
A range of accessories is available for BZ, BA, BM, BE and DT switches, such
as the 5PA2 terminal enclosure. For more information please contact your
local sales office.
TB Series Miniature Double-break
Basic Switches
TB Series miniature double-break basic switches are basic double-break
units that offer a means of controlling isolated circuits. Each circuit may be
driven by an independent voltage source.
Voltage: 250 Vac
Electrical rating: 10 A
Operating temperature: -55 °C to 125 °C [-67 ° F to 257 °F]
Termination: Solder
Contact type: Silver
Approvals: CSA, UL
Switching options: Single pole, double throw, double break (SPDT DB)
12
3
4
0.53
0.50 0.20
0.15
0.24
0.13
0.87 DIA HOLE IN TERMINALS (4)
PLASTIC PLUNGER
1.57
1.825 REF
0.06 MAX PRETRAVEL
0.16 R
0.46
OPERATING
POSITION 0.312 ± .003
0.365
1.25
0.101 DIA HOLE
+.002
- .001
0.101
+.002
- .001
0.532 ± .003
0.03 0.09
0.25 0.50
0.260
0.22
0.113 ± .002 DIA
Dimensions in inches
NOTE-
1 - TERMINALS 1 & 2 NORMALLY CLOSED CIRCUIT
2 - TERMINALS 3 & 4 NORMALLY OPEN CIRCUIT
3 - TERMINALS ARE PLATED FOR SOLDERING
Top pin plunger
ELECTRICAL RATING TERMINATION CAT. LISTING
10 A Solder 1TB1-2
106 www.honeywell.com/sensing
BASIC SWITCHES
SM and SX Series Subminiature Basic
Switches
SM and SX Series subminiature basic switches may be used for simple
or precision on/off application needs. These switches combine small size
and light weight with ample electrical capacity, precision operation and
long life. The SX Series are small, precision, snap-action switches that are
often ideal where savings in space and weight are important.
Voltage: 250 Vac
Operating temperature: -55 °C to 125 °C [-67 ° F to 257 °F]
Termination: Solder
Contact type: Silver
Switching options: Single pole, double throw (SPDT)
SM Series
Approvals: CE, CSA, UL
Electrical rating: 5 A
OPTIONS
Top pin plunger
Approvals: 11SM601-H4 UL, CSA
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
5 A silver 11SM1
Solder/quick connect 5 A silver 11SM601-H4
Straight lever
LEVER LENGTH ELECTRICAL RATING CONTACT TYPE CAT. LISTING
4,83 mm 5 A silver 111SM1
Roller lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Solder/quick connect 5 A silver 111SM2-T
SX Series
Approvals: CE, CSA, UL
Electrical rating: 5 A
OPTIONS
Top pin plunger
Approvals: 6SX7-T UL, CSA
CONTACTS ELECTRICAL RATING CAT. LISTING
Silver 7 A 1SX1-T
Silver 3 A 11SX1-T
Gold 1 A 6SX7-T
Straight lever
CONTACT TYPE ELECTRICAL RATING LEVER LENGTH CAT. LISTING
Silver 5 A ‘A’ 12,8 mm 311SX2-T
Silver 5 A ‘A’ 24,5 mm 311SX3-T
Simulated roller
CONTACT TYPE ELECTRICAL RATING LEVER CAT. LISTING
Silver 5 A Roller 311SX5-T
107
www.honeywell.com/sensing
BASIC SWITCHES
ZM, ZX, ZV and ZW Series Subminiature
Basic Switches
ZM, ZX, ZV and ZW Series subminiature basic switches are cost-effective
devices used for simple on/off applications. These switches combine small
size and light weight with ample electrical capability and long life. Plastic
lever capability is available on the ZV Series.
Electrical rating: 0.1 A, 3 A, 5 A or 10.1 A
Voltage: 125/250 Vac
Operating temperature: 25 °C to 85 °C [-13 °F to 185 °F]
Termination: Quick connect, solder, PCB
Contact type: Gold or silver
Switching options: SPDT
ZM Series
Approvals: UL/CSA
Electrical rating: 0.1 A, 5 A or 10.1 A
OPTIONS
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Quick connect 5 A silver ZM50E70A01
Solder 5 A silver ZM50E10A01
PCB 10.1 A silver ZM90G20A01
Solder 0.1 A gold ZM10B10A01
ZX Series
Approvals: UL/CSA
Electrical rating: 0.1 A or 3 A
OPTIONS
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
PCB 3 A silver ZX40E30A01
Solder 0.1 A gold ZX10C10A01
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
PCB 3 A silver ZX40E30C01
Solder 3 A silver ZX40E10C01
2.05
é2.2
1.5
13.0
5.2
1.12
3.4
12.7
é2.05
PTOP
FP
6.5
5.7
2.9
0.5
0.512
0.044
0.134 0.205
é0.081
0.059
0.081
é0.087
0.224
0.114
0.256
0.124
3.15
0.2 0.2
0.504
12.8
0.256
0.9
0.035 5.08 5.08
6.5
0.228
0.049
5.8
1.24 0.016
0.4
0.138
3.6
0.043
1.1
1.6
0.043
1.1
0.063
3.15
2.05
0.9
é2.2
1.5
12.8
6.5
5.08 5.08
1.12
12.7
5.2
0.4
5.8
3.6
é2.05
1.24
1.1
1.6
1.1
6.5
OP
FP
PT
2.9
5.7
0.044
0.205
0.5
0.114
0.224
0.2560.138
0.0430.043
0.063
0.016
0.049
0.228
é0.081
0.504
0.1240.2560.035
0.20.2
é0.087
0.059
0.081
Top pin plunger
Straight lever
Top pin plunger
108 www.honeywell.com/sensing
Simulated roller lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
PCB 3 A silver ZX40E30E01
Solder 3 A silver ZX40E10E01
ZV Series
Approvals: UL/ENEC
Electrical rating: 0.1 A, 5 A or 10.1 A
OPTIONS
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
PCB 5 A silver ZV50E20A01
Solder 5 A silver ZV50E10A01
Quick connect 0.1 A gold ZV10B70A01
3.4 5.2
1.12
12.7
é2.05
2.05
é2.2
1.5
FP
OP PT
11.8
0.465
0.5
0.044
0.2050.134
0.059
0.081
é0.087 é0.081
0.114
0.224
2.9
5.7
0.256
6.5
0.228
0.049
5.8
1.24 0.016
0.4
0.138
3.6
0.043
1.1
1.6
0.043
1.1
0.063
0.124
3.15
0.2 0.2
0.504
12.8
0.256
0.9
0.035 5.08 5.08
6.5
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Quick connect 5 A silver ZM50E70D01
Solder 5 A silver ZM50E10D01
Straight lever
Simulated roller lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Quick connect 5 A silver ZM50E70E01
Solder 5 A silver ZM50E10E01
BASIC SWITCHES BASIC SWITCHES
Top pin plunger
109
www.honeywell.com/sensing
Straight lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Solder 5 A silver ZV50E10B01
Quick connect 5 A silver ZV50E70C01
Roller lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
PCB 5 A silver ZV50E20F01
Quick connect 5 A silver ZV50E70F01
BASIC SWITCHES
BASIC SWITCHES
ZW Sealed Series
Approvals: UL/ENEC
Electrical rating: 0.1 A or 5 A
Sealing: IP50 and IP67
OPTIONS
Top pin plunger
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Solder 5 A silver ZW50F15AD1
Straight lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Solder 0.1 A gold ZW10E15CD1
Roller lever
TERMINATION ELECTRICAL RATING CONTACT TYPE CAT. LISTING
Wire leads 0.1 A gold ZW10E90FW1
110 www.honeywell.com/sensing
Printed circuit board (PO2)
These terminals interface with snap-on receptacles and other components
from AMPMODU interconnection system.
PCB terminals are European approved when used with electrical ratings A, B,
D, E, S.
V7 Series Miniature Basic Switches
V7 Series basic switches may be used for simple or precision on/off, end
of limit, presence/absence, pressure, temperature and manual operator
interface application needs.
Operating temperature:
-40 °C to 82 °C [-40 °F to 180 °F] (standard)
-40 °C to 200 °C [-40 °F to 350 °F] (high temperature)
Termination: Printed circuit board (PCB)
and two types of quick connect (QC)
D8, E8: 4,8 mm x 0.5 mm [0.187 in x 0.02 in]
E9: 6,35 mm x 0,80 mm [0.25 in x 0.032 in]
Electrical rating Contact Type
V7-*A 5 A Silver
V7-*B 11 A Silver
V7-*C/W 15 A Silver
V7-*D 1 A Gold alloy
V7-*E 10 A Silver
V7-*S 100 mA Gold alloy
V7-*V 21 A Silver alloy
V7-*Z 25 A Silver cadmium oxide
Approvals: CSA, UL, ENEC
V7-*C/W (Electrical ratings) CSA, UL
Switching options: Single pole double throw (NO and NC) (SPDT)
AVAILABLE TERMINALS
Quick Connect (QC)
0.187 in wide x 0.020 in thick. D8 terminals are European approved when
used with electrical ratings A, B, D, E or S. International approval agencies
require that switches with these terminals have insulated receptacles or
connector.
0.187 in wide x 0.020 in thick. E8 terminals are European approved when
used with electrical ratings A, B, D, E or S.
0.250 in wide x 0.032 in thick. E9 terminals are European approved when
used with electrical ratings A, B, D, E, S, V or Z.
ACTUATION OPTIONS
10,2
.40 6,4
.25
COM NC
NO
2,8
.11 1,5
0.06 8,9
.35
0,8
.03
2,4
.10
14,4
.57
22,2
.88
28,8
1.14
3,20
.126
3,46
.134
OPT
18,2
.72
(3)
DIA
3,10
.122
OPT
2,90
.114
10,3
.41
DIA
20,2
.80 2,8
.11
2,8
.11 1,0
.04
2,90
.114 Ø hole (3,10/.122 option)
MAX
Note: The optional mounting hole dimensions shown above are standard on
V5/V7 International Series switches.
Top pin plunger
CURRENT TERMINATION CAT. LISTING
5 A QC (D8) V7-1A17D8
5 A PCB V7-1A17P02
11 A QC (D8) V7-1B17D8
11 A QC (E9) V7-1B19E9
15 A QC (D8) V7-1C17D8
15 A QC (E9) V7-1C17E9
1 A QC (D8) V7-1D10D8
0.1 A QC (D8) V7-1S17D8
21 A QC (E9) V7-1V19E9
25 A QC (E9) V7-1Z19E9
BASIC SWITCHES BASIC SWITCHES
111
www.honeywell.com/sensing
BASIC SWITCHES
V7 Series Miniature Basic Switches
(continued)
Straight lever
Type -002
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A QC (D8) V7-1C17D8-002
15 A QC (E9) V7-1C17E9-002
11 A QC (E9) V7-2B17E9-002
Straight lever
Type -022
ELECTRICAL RATING TERMINATION CAT. LISTING
5 A QC (D8) V7-1A17D8-022
11 A QC (D8) V7-1B19D8-022
15 A QC (D8) V7-1C17D8-022
0.1 A QC (D8) V7-1S17D8-022
Type -048
ELECTRICAL RATING TERMINATION CAT. LISTING
11 A QC(D8) V7-1B17D8-048
15 A QC(D8) V7-1C17D8-048
21 A QC(E9) V7-1V19E9-048
11 A QC(E9) V7-2B19E9-048
0.1 A QC(D8) V7-3S17D8-048
15 A (High temperature) QC(E9) V7-9W1AE9-048
Roller lever
Type -201
ELECTRICAL RATING TERMINATION CAT. LISTING
15 A QC (D8) V7-1C17D8-201
15 A QC (E9) V7-1C17E9-201
0.1 A QC (D8) V7-1S17D8-201
11 A QC (D8) V7-2B17D8-201
Type -207
ELECTRICAL RATING TERMINATION CAT. LISTING
11 A QC (E9) V7-1B10E9-207
15 A QC (D8) V7-1C17D8-207
15 A QC (E9) V7-1C17E9-207
0.1 A QC (D8) V7-1S17D8-207
21 A QC (E9) V7-1V1939-207
5 A QC (D8) V7-2A17D8-207
1 A QC (D8) V7-7D17D8-207
Simulated roller lever
Type -263
ELECTRICAL RATING TERMINATION CAT. LISTING
11 A QC (D8) V7-1B17D8-263
15 A QC (D8) V7-1C17D8-263
0.1 A QC (D8) V7-1S17D8-263
0.1 A QC (E9) V7-3S17E9-263
112 www.honeywell.com/sensing
BASIC SWITCHES
113
www.honeywell.com/sensing
Pressure Switches
Honeywell has over 60 years of experience in the pressure switch
industry. A wide variety of pressure ranges, along with a wide choice of
mounting, package, and port configurations allows customers to
choose from standard off-the-shelf designs.
All Honeywell pressure switches feature excellent repeatability, enhanced
accuracy and reliability under varying environmental conditions. In
addition, they feature highly consistent operating characteristics from
one sensor to the next and interchangeability without recalibration.
PRESSURE SWITCHES
114 www.honeywell.com/sensing
Pressure Switches
5000 Series Extended Duty Switch
Set point range -
0.5 psi to 150 psi [0.035 bar to 10.35 bar]
This pressure switch was designed to stand up to extended duty
applications. It is factory set but is capable of being field adjusted. The
Kapton diaphragm is compatible with a wide variety of media with the
exception of water. An optional Teflon diaphragm is available when water
is the operating media.
Other options are available - SPDT, NO/NO or NC/NC circuitry and blade
or integral Packard MetriPack terminals - contact Honeywell sales office
for details.
Operating pressure:
Set point range 0.5 psi to 24 psi = 150 psi
[0.0345 bar to 1.656 bar] = [10.350 bar]
25 psi to 150 psi = 250 psi
[1.725 bar to 10.350 bar] = [17.237 bar]
Proof pressure: 500 psi (34.474 bar]
Burst pressure:
Set point range 0.5 psi to 24 psi = 750 psi
[0.0345 bar to 1.656 bar] = [51.711 bar]
25 psi to 150 psi = 1250 psi
[1.725 bar to 10.350 bar] = [86.185 bar]
Honeywell’s pressure and vacuum switches are designed for use in
heavy duty equipment. They are suitable for potential applications that
are constantly subjected to harsh environments, such as chemical
splashes, salt water or pressure spikes.
The products listed are standard switches, but other circuitry and
terminal options are available. Switches can be customised to customer
requirements, contact your local Honeywell sales office for more
information.
Operating temperature: -40 °C to 122 °C [-40 °F to 250 °F]
Termination: #8-32 screws
Connector: 1/8-27 NPT male thread
Contacts: Silver alloy, gold plated
Electrical rating: Resistive 15 A, 6 Vdc
8 A, 12 Vdc
4 A, 24 Vdc
Inductive 1 A, 120 Vac
0.5 A, 240 Vac
Circuitry: SPST-NO (Normally open)
SPST-NC (Normally closed)
Direct action blade contacts, 2 terminals
58,42
(2.30)
37,34
(1.47)
SPST-NO
CONTACT SETTING PSI [BAR] FACTORY SET AT PSI [BAR] CAT. LISTING
0.5 to 1.0 [0.0345 to 0.069] 1.0 [0.069] 78628
1.1 to 3.0 [0.0759 to 0.207] 2.0 [0.138] 76051
3.1 to 7.0 [0.2139 to 0.483] 4.0 [0.276] 76575
8.0 to 13.0 [0.552 to 0.897] 10.0 [0.690] 76576
14.0 to 24.0 [0.996 to 1.656] 15.0 [1.035] 76052
25.0 to 50.0 [1.725 to 3.450] 35.0 [2.415] 76053
51.0 to 90.0 [3.519 to 6.210] 60.0 [4.140] 76054
91.0 to 150.0 [6.279 to 10.350] 100.0 [6.90] 76055
SPST-NC
CONTACT SETTING PSI [BAR] FACTORY SET AT PSI [BAR] CAT. LISTING
0.5 to 1.0 [0.0345 to 0.069] 1.0 [0.069] 78632
1.1 to 3.0 [0.0759 to 0.207] 2.0 [0.138] 76061
3.1 to 7.0 [0.2139 to 0.483] 4.0 [0.276] 76577
8.0 to 13.0 [0.552 to 0.897] 10.0 [0.690] 76578
14.0 to 24.0 [0.996 to 1.656] 15.0 [1.035] 76062
25.0 to 50.0 [1.725 to 3.450] 35.0 [2.415] 76063
51.0 to 90.0 [3.519 to 6.210] 60.0 [4.140] 76064
91.0 to 150.0 [6.279 to 10.350] 100.0 [6.90] 76065
NOTE
Operating Media (Pressure Switch)
The pressure switch is designed to operate with air, motor oils,
transmission oils, jet fuels and other similar hydrocarbon media.
PRESSURE SWITCHES
115
www.honeywell.com/sensing
5000 Series Extended Duty Vacuum Switch
Set point range -
1.1 in to 22.0 in Hg
[27,94 mm Hg to 558,80 mm Hg]
The 5000 Series Extended Duty Vacuum switch is designed for vacuum
applications. The factory setting cannot be changed or adjusted in the
field. It features a fluorosilicone rubber diaphragm that is compatible with
a wide range of media.
Blade terminal option is also available.
Connector 1/8-27 NPT Male
Operating vacuum: 30 in Hg [762 mm Hg]
Burst pressure: 150 psi [10.35 bar]
Direct action blade contacts
58,42
(2.30)
37,34
(1.47)
SPST-NO
CAT. LISTING
Internally grounded, 1 Terminal 78813
2 Terminals 77342
SPST-NC
CAT. LISTING
Internally grounded, 1 Terminal 78815
2 Terminals 77343
5000 Series Extended Duty Piston Switch
Set point range -
70 psi to 1000 psi [13.80 bar to 68.95 bar]
This switch is a variation of the “standard” 5000 Series Extended duty
switch for applications requiring a compact package size, enhanced set
point and operating characteristics.
Other options are available - SPDT, NO/NO or NC/NC circuitry and blade
terminals - contact Honeywell sales office for details.
Termination: #8-32 screws or 280 Series MetriPack
Connector: 1/2-20 UNF [O-ring fitted]
Operating pressure: 1000 psi [68.95 bar]
Proof pressure: 2000 psi [138.00 bar]
Burst pressure: 3000 psi [206.84 bar]
OPTIONS
Standard screw terminal, direct action blade
contacts
62,23
(2.45)
37,34
(1.47)
SPST-NO
CONTACT SETTING PSI [BAR] APPROX. DIFFERENTIAL PSI [BAR] CAT. LISTING
70 to 400 [13.80 to 27.60] 30 to 100 [2.07 to 6.90] 79700
401 to 800 [27.67 to 55.20] 40 to 125 [2.76 to 8.625] 79704
801 to 1000 [55.27 to 69.00] 50 to 180 [3.45 to 12.42] 79708
SPST-NC
CONTACT SETTING PSI [BAR] APPROX. DIFFERENTIAL PSI [BAR] CAT. LISTING
70 to 400 [13.80 to 27.60] 30 to 100 [2.07 to 6.90] 79702
401 to 800 [27.67 to 55.20] 40 to 125 [2.76 to 8.625] 79706
801 to 1000 [55.27 to 69.00] 50 to 180 [3.45 to 12.42] 79710
Metri-Pack terminal, direct action blade contacts
77,47
(3.05)
37,34
(1.47)
SPST-NO
CONTACT SETTING PSI [BAR] APPROX. DIFFERENTIAL PSI [BAR] CAT. LISTING
200 to 350 [13.80 to 24.15] 30 to 100 [2.07 to 6.90] 79718
351 to 500 [24.22 to 34.50] 40 to 125 [2.76 to 8.625] 79720
501 to 750 [34.57 to 51.75] 50 to 150 [3.45 to 12.42] 79722
SPST-NC
CONTACT SETTING PSI [BAR] APPROX. DIFFERENTIAL PSI [BAR] CAT. LISTING
200 to 350 [13.80 to 24.15] 30 to 100 [2.07 to 6.90] 79719
351 to 500 [24.22 to 34.50] 40 to 125 [2.76 to 8.625] 79721
501 to 750 [34.57 to 51.75] 50 to 150 [3.45 to 12.42] 79723
Mating connector - Packard Part Number 15300027
PRESSURE SWITCHES
116 www.honeywell.com/sensing
PRESSURE SWITCHES
Pressure Switches -
Customised
The pressure and vacuum switches on the following pages are custom
built to customer specification, therefore minimum order quantities are
required. Catalog listings are for reference only. Standard specification is
shown below, but other contact, termination and connector options are
available. Contact Honeywell for more information.
Operating temperature: -40 °C to 122 °C
[-40 °F to 250 °F]
Termination: 8 in (203,2 mm) wire leads - 18 ga
Connector: 1/8-27 PTF SAE short male thread
Contacts: Gold over silver
Electrical rating: Resistive 15 A, 6 Vdc
8 A, 12 Vdc
4 A, 24 Vdc
Inductive 1 A, 120 Vac
0.5 A, 240 Vac
Circuitry: SPST-NO (Normally open)
SPST-NC (Normally closed)
SPDT (Dual circuit)
Series III
Factory Set Variable Differential
Pressure and Vacuum Switches
The Series III features a snap action switch with gold contacts that
provides hysteresis, low contact resistance, enhanced transfer time and
an adjustable differential.
Operating pressure: 200 psi [13.80 bar]
Proof pressure: 350 psi [24.13 bar]
Burst pressure: 500 psi [34.49 bar]
63,50
(2.5)
42,93
(1.69)
OPTIONS
Pressure switch, snap action contacts
Set point range - 2 psi to 70 psi [0.138 bar to 4.83 bar]
SET POINT RANGE PSI [BAR] DIFFERENTIAL PSI [BAR] REF. LISTING
2 to 4 [0.138 to 0.276] 1 to 1.5 [0.069 to 0.103] 120000
4 to 12 [0.276 to 0.828] 2 to 6 [0.138 to 0.414] 120001
12 to 24 [0.828 to 1.656] 8 to 12 [0.552 to 0.828] 120002
24 to 40 [1.656 to 2.760] 10 to 18 [0.690 to 1.242] 120003
40 to 70 [2.760 to 4.830] 15 to 20 [1.035 to 1.380] 120004
Vacuum switch, snap action contacts
Set point range -
1.1 in Hg to 22 in Hg [27,94 mm Hg to 558,8 mm Hg]
SET POINT RANGE IN HG [MM HG] DIFFERENTIAL IN HG [MM HG] REF. LISTING
15 in H2O to 36 in H2O [28,025 to 67,259] 4 in H2O to 12 in H2O [7,473 to 22,420] 120005
2 to 6 [50,8 to 152,4] 0.4 to 1 [10,16 to 25,40] 120006
6 to 12 [152,4 to 304,8] 0.4 to 1 [10,16 to 25,4] 120007
12 to 22 [304,8 to 558,8] 0.6 to 1.5 [15,24 to 38,1] 120008
5000 Series Ultra Duty Switch
Set point range -
10 psi to 400 psi [0.69 bar to 27.60 bar]
The 5000 Series Ultra Duty pressure switch is designed for high
pressure/low set point applications that can experience sudden pressure
spikes and high system pressures. Screw machined and heat treated
components along with a reduced effective area in the pressure cavity
allow improved performance over the standard extended duty 5000
Series.
Other options are available - Dual Circuit (SPDT) configuration and blade
or integral Packard MetriPack terminals - contact Honeywell sales office
for details.
Connector 1/8-27 NPT Male
Operating pressure: 500 psi [34.50 bar]
Proof pressure: 2000 psi [138.00 bar]
Burst pressure: 4000 psi [276.00 bar]
Direct action blade contacts, 2 terminals
58,42
(2.30)
37,34
(1.47)
SPST-NO
CONTACT SETTING PSI (BAR] FACTORY SET AT PSI [BAR] CAT. LISTING
10 to 35 [0.69 to 2.41] 20 [1.38] 83298
35 to 75 [2.41 to 5.17] 60 [4.14] 83301
75 to 150 [5.17 to 10.35] 100 [6.90] 83304
150 to 250 [10.35 to 17.25] 200 [13.89] 83307
250 to 400 [17.25 to 27.6] 300 [20.70] 83310
SPST-NC
CONTACT SETTING PSI [BAR] FACTORY SET AT PSI [BAR] CAT. LISTING
10 to 35 [0.69 to 2.41] 20 [1.38] 83299
35 to 75 [2.41 to 5.17] 60 [4.14] 83302
75 to 150 [5.17 to 10.35] 100 [6.90] 83305
150 to 250 [10.35 to 17.25] 200 [13.89] 83308
250 to 400 [17.25 to 27.6] 300 [20.70] 83311
117
www.honeywell.com/sensing
PRESSURE SWITCHES
Pressure Switches - Customised
(continued)
Series V
High Pressure, Environmentally Sealed,
Extreme Duty Switches
Set point range -
35 psi to 3000 psi [2.415 bar to 206.84 bar]
The Series V features a snap action switch with gold-plated contacts that
provides hysteresis, low contact resistance, enhanced transfer time and
an adjustable differential.
OPTIONS
Diaphragm switch, snap action contacts
Set point range -
35 psi to 300 psi [2.415 bar to 20.70 bar]
The diaphragm material is fluorosilicone and is compatible with air,
motor and transmission oil and other hydrocarbon media.
Connector: 1/8-27 PTF
Operating pressure: 300 psi [20.70 bar]
Proof pressure: 500 psi [34.47 bar]
Burst pressure: 2000 psi [138.00 bar]
81,03
(3.19)
30.15
(1.187)
SET POINT RANGE PSI [BAR] DIFFERENTIAL PSI [BAR] REF. LISTING
35 to 50 [2.415 to 3.45] 10 to 15 [0.690 to 1.035] 26900
50 to 100 [3.45 to 6.90] 10 to 15 [0.690 to 1.035] 26901
100 to 200 [6.90 to 13.80] 10 to 15 [0.690 to 1.035] 26902
200 to 300 [13.80 to 20.70] 10 to 20 [0.690 to 1.380] 26903
Piston seal switch, snap action contacts
Set point range -
100 psi to 3000 psi [6.90 bar to 206.84 bar]
The piston seal is nitrile and is compatible with motor and transmission
oil and other hydrocarbon media. An optional seal is available for use
with brake fluid.
Connector: 3/4-16 UNF (O-ring fitting)
Operating pressure: 3000 psi [206.84 bar]
Proof pressure: 5000 psi [345.00 bar]
Burst pressure: 10000 psi [690.00 bar]
84,84
(3.34)
30.15
(1.187)
SET POINT RANGE PSI [BAR] DIFFERENTIAL PSI [BAR] REF. LISTING
100 to 150 [6.90 to 10.35] 35 to 50 [2.415 to 3.450] 26904
150 to 250 [10.35 to 17.25] 50 to 75 [3.450 to 5.175] 26905
250 to 500 [17.25 to 34.50] 75 to 100 [5.175 to 6.90] 26906
500 to 750 [34.50 to 48.30] 100 to 150 [6.90 to 10.35] 26907
750 to 1000 [48.30 to 69.00] 150 to 300 [10.35 to 20.70] 26908
1000 to 1250 [69.00 to 86.25] 175 to 350 [12.075 to 24.15] 26909
1250 to 1500 [86.25 to 103.50] 175 to 360 [12.075 to 24.84] 26910
1500 to 1750 [103.50 to 120.75] 220 to 370 [15.18 to 25.53] 26911
1750 to 2000 [120.75 to 138.00] 230 to 380 [15.87 to 26.22] 26912
2000 to 2250 [138.00 to 155.25] 250 to 390 [17.25 to 26.91] 26913
2250 to 2500 [155.25 to 172.50] 355 to 400 [24.495 to 27.60] 26914
2500 to 2750 [172.50 to 189.75] 370 to 420 [25.53 to 28.98] 26915
2750 to 3000 [189.75 to 206.84] 385 to 450 [26.565 to 31.05] 26916
118 www.honeywell.com/sensing
119
www.honeywell.com/sensing
Environment Sealed,
Hermetically Sealed
and Manual switches
ENVIRONMENT SEALED SWITCHES
Most of the products in this section have one
thing in common - they are sealed to withstand
harsh environments.
You will find them in such diverse places as
landing gears, flaps, cargo doors and cockpit
panels. Environmentally sealed products also
satisfy needs in many other potential
applications. Some examples are agriculture,
transportation, construction, marine, ordnance
and command and control equipment.
Our commitment to quality products begins
with the design of the products. Marketing,
design and manufacturing engineering
personnel review the customer specifications
and translate them into design and
manufacturing instructions. Every product
Honeywell manufactures, be it an aerospace,
industrial or commercial design, follows a
single, uniform system of quality assurance.
This helps ensure the same high level of
reliability in all our products. Our aim is to build
in quality.
We have evaluation test labs that can subject
our designs to most every test and
environmental condition known to exist in our
world or in outer space. Test equipment
includes - electrical and mechanical life cycling
devices, high-low temperature chambers,
hydrostatic pressure chambers, impact shock
machines, vibration equipment, centrifugal
acceleration equipment, humidity and salt
spray chambers, and dielectric strength testing
equipment.
To ensure you have the latest information on
our product offering, contact Honeywell.
Switch load/life
Switch life depends on such criteria as electrical
load, environment, switch mechanism and other
factors peculiar to the application. As electrical load
increases, switch life decreases. For military
qualification testing 25,000 operations electrical life
at rated load (maximum recommended load) is the
minimum operations required. In most cases
switch life exceeds 25,000 operations when
operated at electrical loads less than rated load.
Below one amp, the electrical life approaches the
mechanical life of the switch. If your application
requires more than 25,000 cycles and your
electrical load is less than rated load, please contact
Honeywell for application assistance.
Sealed basic switches and switch
assemblies
Basic switches are either environment sealed or hermetically sealed. The environment sealed
basics have a watertight seal and most meet military specifications. Limit switches are environment
sealed or hermetically sealed and some are suitable for high temperature applications. Most
switches meet appropriate military requirements. Environment sealed limit switches come in a
choice of sizes and are offered for military aerospace and commercial aircraft applications.
Hermetically sealed switches withstand temperatures up to 125 °C [257 °F], and high temperature
hermetically sealed switches will operate in temperatures up to 334 °F [615 °F].
Manual control switches
Standard size and some miniature toggle switches have bushing seals and are military qualified. Rocker
switches also have a bushing seal. Rockers are easy to remove and are available in a variety of colours.
Magnetically held toggle switches contain a holding coil to maintain the toggle in the operated position.
They have environment sealing, and most are military qualified.
120 www.honeywell.com/sensing
Military specifications
procurement information
How to increase your effectiveness
in using specification MIL-PRF-
8805
The following information is intended to increase
your effectiveness in using the Specification
MIL-PRF-8805, minimize your costs and
reduce delivery time for switches procured to
the Specification.
Standard items
(shown on QPL 8805)
HONEYWELL suggests the following statement be
used when ordering items appearing on QPL
8805:
“Honeywell” catalog listing No. listed on QPL
8805 as No. .”
Should additional requirements be needed for
application of the switch in its end use, they
should be specifically stated as part of the
ordering information.
Non-standard items
(not shown on QPL 8805)
Honeywell suggests the following statement be
used when ordering items which do not appear on
QPL 8805:
“Switch drawing No. shall meet the following
performance requirements of MIL-PRF-8805.”
The above statement to be supplemented by
the performance requirements which you
consider applicable.
Why the suggested statements will
minimize cost and delivery of non-
standard items
Military Specification MIL-PRF-8805 requires a
complete qualification test of non-standard items
(unless you specifically call out the performance
requirements which you consider applicable to
your switch application). Complete qualification
is costly and will delay shipment of switches. By
specifying all those requirements which you
consider applicable you can minimize both your
cost and delivery flow time. General statements,
such as “switch must meet requirements of
MIL-PRF-8805”, require complete MIL-PRF-
8805 qualification tests.
Honeywell believes that you, the user, know
best the specific requirements of your
application. These requirements may be more
or less severe than those reflected by the test
parameters of MIL-PRF-8805. In the interest of
supplying switches which will meet your
requirements with a minimum of expense and
delay, we suggest use of the applicable
statement provided for Standard (QPL) items
and Non-Standard items (not on QPL).
Honeywell solicits submittal of your proposal
prints for review and comment. This review
may result in savings of time and cost for you.
Basic switches
operating characteristics
Electromechanical switches
Definitions below explain the meaning of operating characteristics. Characteristics shown in tables
throughout this catalog were chosen as most significant. They are taken at normal room temperature
and humidity. These characteristics may vary as temperature and humidity conditions differ.
Sketches show how characteristics are measured for in-line plunger actuation.
Linear dimensions for in-line actuation are from top of plunger to a reference line, usually the
center of the mounting holes.
Differential Travel (D.T.)—Plunger or actuator travel from point where contacts “snap-over” to
point where they “snapback.”
Free Position (F.P.)—Position of switch plunger or actuator when no external force is applied
(other than gravity).
Full Overtravel Force—Force required to attain full overtravel of actuator.
Operating Position (O.P.)—Position of switch plunger or actuator at which point contacts snap
from normal to operated position. Note that in the case of flexible or adjustable actuators, the
operating position is measured from the end of the lever or its maximum length. Location of
operating position measurement shown on mounting dimension drawings.
Operating Force (O.F.)—Amount of force applied to switch plunger or actuator to cause contact
“snap-over.” Note in the case of adjustable actuators, the force is measured from the maximum
length position of the lever.
Overtravel (O.T.)—Plunger or actuator travel safely available beyond operating position.
Pretravel (P.T.)—Distance or angle traveled in moving plunger or actuator from free position to
operating position.
Release Force (R.F.)—Amount of force still applied to switch plunger or actuator at moment contacts
snap from operated position to unoperated position.
Total Travel (T.T.)—Distance from actuator free position to overtravel limit position.
In-line plunger actuation
Toggle switch locking configurations
Toggle switches are available with the following locking configurations -
ABDEFGH
Locked In Locked Out Of
Center and Locked Out Locked In Locked In Center And
Locked In Extreme Position Of Center Locked In Extreme Position Extreme Position Extreme Position
Three Positions (Keyway Side) Position Center Position (Opposite Keyway) (Keyway Side) (Keyway Side)
JKLMNP
Locked Out Of Locked In Locked Out Of Locked Out Of
Center And Center And Locked Out Of And Into Locked Out Of And Into
Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position
(Opposite Keyway) (Opposite Keyway) (Keyway Side) (Opposite Keyway) (Opposite Keyway) (Keyway Side)
SEALED SWITCHES
121
www.honeywell.com/sensing
SEALED SWITCHES
SE and XE Series
Environmentally Sealed
Basic Switches
SE and XE Series switches are the smallest, environment sealed switches
offered by Honeywell. They enclose basic switches within a corrosion-
resistant aluminum housing to seal precision switch contacts from
contamination. SE switches include a SM basic switch; XE switches include
the smaller SX basic switch.
Housing material: Aluminium
Sealing: Watertight seal per MIL-PRF-8805, symbol 3
Termination: 305,0 mm [1 ft] leadwire or Solder (turret)
Contacts: Silver
Switching options:
SPDT Single Pole, Double Throw
SPNC Single Pole, Normally Closed
SPNO Single Pole, Normally Open
Electrical ratings: A 5 A res., 3 A ind., (sea level),
5 A res., 2.5 A ind., [50000 ft], 28 Vdc
5 A res., 5 A ind., 125 or 250 Vac, 60 Hz
BUL/CSA rating - 5A, 250 Vac, 60 Hz
C7 A res., 4 A ind., (sea level)
7 A res., 2.5 A ind., [50000 ft], 28 Vdc
7 A res., 4 A ind., (sea level)
115 Vac, 400 Hz
DUL Rating - 7 A, 250 Vac, 60 Hz
E7 A res., 4 A ind., (sea level)
7 A res., 2.5 A ind., [50000 ft], 28 Vdc
F1 A res., 0.5 A ind., 28 Vdc
122 www.honeywell.com/sensing
SEALED SWITCHES
SE Series
Package size: 19,05 mm H x 8,64 mm W x 22,35 mm L
[0.75 in H x 0.34 in W x 0.88 in L]
Operating temperature:
Standard -53 °C to 105 °C [-65 °F to 221 °F]
Low -26 °C to 80 °C [-15 °F to 185 °F]
Approvals: UL, CSA (4SE1 only)
Operating force max. (OF):
Standard 1,39 N to 4,73 N [5.0 oz to 17.0 oz]
Low 1,11 N to 2,22 N [4.0 oz to 8.0 oz]
High 1,39 N to 5,28 N [5.0 oz to 19.0 oz]
Pretravel max. (PT): 1,27 mm [0.050 in]
Overtravel min. (OT): 0,08 mm [0.003 in]
Differential travel max. (DT): 0,10 mm [0.004 in]
Top pin plunger
OPTIONS
SPDT Single Pole, Double Throw
Leadwire termination
FEATURES ELECTRICAL RATING CAT. LISTING
A 1SE1
Gold contacts F 1SE7
Gold bifurcated contacts F 1SE401
UL/CSA listing/leadwires B 4SE1
Fluorosilicone seal/Low temperature A 5SE1
Low OF A 7SE1
Solder (Turret) termination
FEATURES ELECTRICAL RATING CAT. LISTING
A 1SE1-T
Gold contacts F 1SE61-T
High OF A 12SE4-T
SPNC Single Pole, Normally Closed
Leadwire termination
ELECTRICAL RATING CAT. LISTING
A 1SE2
SPNO Single Pole, Normally Open
Leadwire termination
ELECTRICAL RATING CAT. LISTING
A 1SE3
Solder (Turret)
Leadwire
123
www.honeywell.com/sensing
SEALED SWITCHES
SE Series Auxiliary actuators
(Switches must be ordered separately)
Operating force max. (OF): 3,34 N [12 oz]
Pretravel max. (PT): 3,81 mm [0.150 in]
Overtravel min. (OT): 0,38 mm [0.015 in]
Differential travel max. (DT): 0,64 mm [0.025 in]
Straight leaf
CAT. LISTING
JE-1
Roller leaf , perpendicular
CAT. LISTING
JE-4
Roller leaf
CAT. LISTING
JE-5
124 www.honeywell.com/sensing
SEALED SWITCHES
XE Series
Package size: 19,05 mm H x 8,13 mm W x 15,75 mm L
[0.75 in H x 0.32 in W x 0.62 in L]
Operating temperature:
Standard -55 °C to 85 °C [-67 °F to 185 °F]
High -53 °C to 149 °C [-65 °F to 300 °F]
Low -26 °C to 85 °C [-15 °F to 185 °F]
Approvals: UL, CSA (4XE1 only)
Operating force max. (OF):
Standard 1,39 N to 4,73 N [5.0 oz to 17.0 oz]
Low 2,50 N [9 oz]
Pretravel max. (PT):
Standard 1,27 mm [0.05 in]
Low 0,76 mm [0.03 in]
Overtravel min. (OT): 0,10 mm [0.004 in]
Differential travel max. (DT): 0,13 mm [0.005 in]
Top pin plunger
OPTIONS
SPDT Single Pole, Double Throw
Leadwire termination
FEATURES ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
C MS27994-1 1XE1
C MS27994-4 1XE201
Gold contacts F MS27994-5 1XE301
Gold bifurcated contacts/
high temperature/1524 mm [6 ft]
leadwire length F 1XE401-6
Low OF/Low PT/high temperature E 14XE1
UL/CSA listing/leadwires D 4XE1
Fluorosilicone seal/low temperature C 5XE1
Solder (Turret) termination
FEATURES ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
A MS27994-3 1XE1-T
Gold bifurcated contacts/
high temperature F 1XE401-T
Gold contacts F 1XE99-T
Low OF/Low PT/high temperature E 14XE1-T
SPNO Single Pole, Normally Open
Leadwire termination
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
C 1XE3
Solder (Turret)
Leadwire
125
www.honeywell.com/sensing
SEALED SWITCHES
XE Series Auxiliary actuators
(Switches must be ordered separately)
Operating force max. (OF): 5,84 N [21 oz]
Pretravel max. (PT): 3,18 mm [0.12 in]
Overtravel min. (OT): 0,23 mm [0.01 in]
Differential travel max. (DT): 0,30 mm [0.01 in]
Straight leaf
10,9
0.43
CAT. LISTING
JM-1
Roller leaf
16,0
0.63
CAT. LISTING
JM-5
126 www.honeywell.com/sensing
HM Series
Miniature, Hermetically
Sealed, Basic Switches
HM Series hermetically sealed basic switches contain contacts in a sealed
chamber. A gas-tight seal is maintained while transmitting force and motion
to the switch mechanism through a metal diaphragm.
This series is not generally recommended for 115 Vac, 60 Hz. If you have a
60 Hz application in the mA range, or applications that require the switch to
function electrically during exposure to sub-freezing temperatures, contact
Honeywell for special design variations that are available.
Package size: 18,29 mm H x 6,35 mm W x 22,35 L
(0.72 in H x 0.25 in W x 0.88 in L]
Housing material: Stainless Steel
Sealing: Hermetic MIL-PRF-8805, design symbol 5
Termination: Solder or leadwire
Operating force max. (OF): 1,95 N [7.00 oz]
Pretravel max. (PT): 0,76 mm [0.03 in]
Overtravel min. (OT): 0,08 mm [0.003 in]
Differential travel max. (DT): 0,15 mm [0. 006 in]
Switching options:
SPDT Single Pole, Double Throw
Electrical ratings:
A1 A res., 0.25 A ind., (sea level or 70000 ft), 28 Vdc
B4 A res., 2 A ind., (sea level), 28 Vdc
C0.5 A res., 0.25 A ind., (sea level or 70000 ft), 28 Vdc
D3 A res., 1 A ind. (sea level or 70000 ft), 28 Vdc
1 A res., or ind. (sea level), 115 Vac, 400 Hz
E0.1 A res., 0.1 A ind., 28 Vdc
Temperature range:
1-65 °C to 121 °C [-85 °F to 257 °F]
2-65 °C to 176 °C [-85 °F to 350 °F]
3-65 °C to 260 °C [-85 °F to 500 °F]
4-184 °C to 121°C [-300 °F to 250 °F]
5-184 °C to 260 °C [-300 °F to 500 °F]
Integral lever
OPTIONS
Leadwire termination
CABLE CONTACT TEMPERATURE ELECTRICAL MILITARY PART CAT. LISTING
LENGTH MATERIAL RANGE RATING NUMBER
152,4 mm [6 in] Gold 2 E 114HM1-2 [1]
304,8 mm [1 ft] Gold Bifurcated 3 C 20HM1-1
304,8 mm [1 ft] Silver 1 B MS27216-2 2HM19-1
1524,0 mm [5 ft] Silver 1 B MS27216-4 2HM19-5
[1] Mechanical life 100 000 operations
Leadwire, potted
CABLE CONTACT TEMPERATURE ELECTRICAL MILITARY PART CAT. LISTING
LENGTH MATERIAL RANGE RATING NUMBER
304,8 mm [1 ft] Silver cadmium 3 B 6HM1-1
oxide
SEALED SWITCHES
Application notes
1 Honeywell does not recommend the use of silver cadmium oxide switch
contacts in non-arcing loads. Non-arcing loads are generally loads less
than 12 V and/or 0.5 A. Catalog listings in the 5, 6, 15, and16HM Series
use silver cadmium oxide contacts. If you have specific questions,
contact Honeywell.
2 For applications involving non-arcing loads, catalog listings in the 9, 10,
19 and 20HM Series are recommended.
127
www.honeywell.com/sensing
HM Series, Integral lever (continued)
Solder termination
CONTACT TEMPERATURE ELECTRICAL MILITARY PART CAT. LISTING
MATERIAL RANGE RATING NUMBER
Silver 4 D MS27216-5 11HM1
Gold 4 A 13HM1
Gold Bifurcated 5 C 19HM1
Gold Bifurcated 5 C 19HM4
[2]
Gold Bifurcated 4 C MS27216-6 9HM1
Gold Bifurcated 4 C 109HM1
[3]
[2] Only metal and glass material exposed external to switch (i.e. vacuum application consideration)
[3] Mechanical life 100 000 operations
Electrical life 25 000 operations at full rated load
Solder, weld
8,4
.33
CONTACT TEMPERATURE ELECTRICAL MILITARY PART CAT. LISTING
MATERIAL RANGE RATING NUMBER
Silver cadmium oxide 3 D 15HM2
Silver cadmium oxide 5 D 15HM5 [2]
HM Series Auxiliary actuators
(Switches must be ordered separately)
Operating force max. (OF): 2,50 N [9.0 oz]
Overtravel min. (OT): 0,76 mm [0.030 in]
Differential travel max. (DT): 0,76 mm [0. 030 in]
Straight leaf
CAT. LISTING
JS-254
Roller leaf
CAT. LISTING
JS-151
Mounting plate
A force spreading plate is recommended to reduce the risk of product
damage due to excessive mounting force.
12,19
(0.48)
15,75
(0.062)
9,525
(0.375) 0,79
(0.031)
Ø 2 x 2,39
(0.094)
CAT. LISTING
19PA137-HM
Notice
Torque on #2 mounting screws must be restricted to
0,16 N m [1.5 in lb] max. to prevent switch damage. The
force spreading mounting plate 19PA137-HM will allow up
to 0,28 N m [2.5 in lb] of mounting torque.
SEALED SWITCHES
128 www.honeywell.com/sensing
HS Series
Hermetically Sealed Basic
Switches
HS Series Hermetically Sealed Switches are designed for potential
applications where maximum electrical rating and maximum sealing are
essential, and where size and weight requirements are less critical. These
switches are side-mounted through mounting holes located outside the
sealed switching chamber.
SEALED SWITCHES
Package size: Standard25,4 mm H x 17,8 mm W x 50,8 mm L
[1.0 in H x 0.7 in W x 2.0 in L]
Housing material: Stainless Steel, phenolic
Sealing: Hermetic MIL-S-8805, design symbol 5
Operating temperature: Standard -55 °C to 125 °C
[-67 °F to 250 °F]
High -55 °C to 149 °C
[-67 °F to 300 °F]
Approvals: UL, CSA (screw terminals)
Termination: Screw or leadwire
Operating force max. (OF): 2,78 N to 6,12 N [10 oz to 22 oz]
Pretravel max. (PT): 1,65 mm [0.065 in]
Overtravel min. (OT): 0,25 mm [0.010 in]
Differential travel max. (DT): 0,51 mm [0.020 in]
Contacts: Silver
Switching options:
SPDT Single Pole, Double Throw
Electrical ratings: A 25 A res., 8 A ind., 28 Vdc
1 A res., 1 A ind, 115 Vac
UL-CSA rating - 1 A, 125 Vac
B15 A res., 8 A ind., 28 Vdc
0.5 A res., 1A ind., 125 Vac
C15 A res., 8 A ind., 28 Vdc
0.5 A res., 1A ind., 125 Vac
UL-CSA rating - 1 A, 125 Vac
D25 A res., 8 A ind., 28 Vdc
0.5 A res., 1 A ind., 125 Vac
UL-CSA rating - 1A, 125 Vac
OPTIONS
Top roller lever
Screw termination
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
A1HS3
129
www.honeywell.com/sensing
SEALED SWITCHES
Integral lever
Screw termination
Standard
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
A MS25011-1 1HS1
D101HS1
High Temperature
Operating force (OF): 2,78 N to 8,34 N [10 oz to 30 oz]
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
C102HS1
Increased operating force
Operating force (OF): 6,12 N to 7,78 N [22 oz to 28 oz]
Pretravel max. (PT): 2,16 mm [0.85 in]
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
A MS25011-4 1HS6
Leaf - added overtravel
Operating force (OF): 1,11 N to 5,56 N [4 oz to 20 oz]
Pretravel max. (PT): N/A
Overtravel max. (OT): 1,57 mm [0.062 in]
Differential travel max. (DT): 2,54 mm [0.100 in]
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
A1HS41
Leadwire termination
ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
B 4HS4-118
130 www.honeywell.com/sensing
SEALED SWITCHES
HT Series
High Temperature Basic
Switches
HT Series High Temperature Switches are designed to withstand
temperatures up to +538 °C [+1000 °F]. The switching element is
mounted on a ceramic base with a stainless steel enclosure.
Note: HT Series switches are not classified as sealed switches.
Package size: Standard 31,75 mm H x 17,78 mm W x 49,78 mm L
[1.25 in H x 0.70 in W x 1.96 in L]
Housing material: Ceramic/Stainless Steel
Sealing: No
Operating temperature: 538 °C [1000 °F]
Approvals: UL, CSA
Termination: Screw
Electrical rating: 3 A, 1/10 HP, 125 Vac
2 A, 1/6 HP, 250 Vac
Switching options:
SPDT Single Pole, Double Throw
OPTIONS
Top pin plunger, panel mount
Operating force max. (OF): 2,78 N to 5,6 N [10 oz to 20 oz]
Pretravel max. (PT): 1,65 mm [0.06 in]
Overtravel min. (OT): 4,78 mm [0.19 in]
Differential travel max. (DT): 0,25 mm [0.01 in]
CAT. LISTING
1HT1
Top pin plunger, side mount
Operating force max. (OF): 2,78 N to 5,6 N [10 oz to 20 oz]
Pretravel max. (PT): 1,27 mm [0.05 in]
Overtravel min. (OT): 0,25 mm [0.01 in]
Differential travel max. (DT): 0,25 mm [0.01 in]
CAT. LISTING
2HT1
Top roller plunger, panel mount
Operating force max. (OF): 8.34 N [30 oz]
Pretravel max. (PT): 1,65 mm [0.06 in]
Overtravel min. (OT): 4,78 mm [0.19 in]
Differential travel max. (DT): 0,254 mm [0.01 in]
CAT. LISTING
3HT1
131
www.honeywell.com/sensing
EN Series
Environment Sealed
Limit Switches
The EN Series Environment-sealed Limit Switch has resilient sealing as defined in MIL-S-8805,
Symbol 4. In addition to the standard versions, miniature housing constructions may be available
with similar actuator styles. The miniature versions may meet the demand for smaller size and
lighter weight without sacrificing performance or electrical capacity. The miniature version housing
is 7,92 mm [0.312 in] smaller in diameter and weighs 14,2 g [0.5 oz] less than the standard
version.
Housing material: Stainless Steel
Sealing: Hermetic MIL-PRF-8805, design symbol 4
Operating temperature: -54 °C to 85 °C [-65 °F to 185 °F]
Termination: 1,829 m [6 ft] Leadwire (#18 and #20)
Receptacle (bottom or side)
Contacts: Silver
Switching options:
DPDT Double Pole, Double Throw
1
4
2
3
5
6
4PDT 4 Pole, Double Throw
1
4
2
3
5
6
7
10
8
9
11
12
1 CKT, DB Single Pole, Double Throw, Double Break
3
2
4
1
2 CKT, DB Double Pole, Double Throw, Double Break
1
4
2
3
5
8
6
7
SEALED SWITCHES
132 www.honeywell.com/sensing
SEALED SWITCHES
Explanations of switches with special features
Low force operation (Low OF)
Special spring construction within this switch reduces the normal 6 lb to 12 lb [26,7 N to 53,4 N]
EN operating force to 3 lb to 6 lb[13,3 N to 26,7 N]. This switch is also dimensionally
interchangeable with the standard size 1EN1-6. Low force 600 series ENs have 3 to 6 pounds
[13,3 to 26,7 N] of operating force.
Increased overtravel (High OT)
A longer plunger and bushing on the switch extends the EN overtravel capabilities from the normal
0.25 in to 0.86 in [6,35 mm to 21,8 mm]. The longer bushing also permits additional adjustment
of the plunger position.
High impact shock (High shock)
Catalog listing 1EN75-R3 (M8805/65-001) has been qualified to MIL-PRF-8805, including high
impact shock class H. Other switches rated for high impact shock applications incorporate the
same plunger mechanism and internal switch design as used in the 1EN75-R3 and are expected to
conform to the same requirements.
Switch dimensions
Where there is no dimension drawing shown, combine housing height and diameter with actuator for
overall measurement.
Electrical Specifications
The electrical ratings charted below are referenced in the order guides. Refer to
Appropriate MIL specification for ratings applicabl e to specific switches.
DC Ratings (Amps)
Rating2 Sea Level 50,000 Feet
Code Voltage Inrush Motor Res. Ind. Inrush Motor Res. Ind.
A 28 Vdc 24 4 4 2 24 43 4
1 2
B 28 Vdc 36 6 10 3 36 63 10 3
C 28 Vdc 30 5 15 10 30 53 15 10
D 28 Vdc 24 4 5 3 N/A
E 28 Vdc N/A 1 .5 N/A 1 .5
F 28 Vdc 24 4 7 4 24 43 7 2.5
Notes:
1 5 amps for rotary switches.
2 For other electrical data, contact your nearest Honeywell office, MI L-S-8805 ratings apply when
this specification is invoked.
3 Application information only.
AC Ratings
Sea Level
Motor Rating
Code Voltage Make Break Res. Ind.
125/460 Vac @ 60 Hz 24 4 5 3 A & D
125 Vac @ 400 Hz 24 4 5 5
125/250 Vac @ 60 Hz 20 3 5 5
460 Vac @ 60 Hz 20 3 3 3
B
125 Vac @ 400 Hz 36 6 10 6
125/250 Vac @ 60 Hz 20 3 5 5
460 Vac @ 60 Hz 20 3 3 3
C
125 Vac @ 400 Hz 30 5 10 6
125/460 Vac @ 60 Hz 12 2 2 2 F
125 Vac @ 400 Hz 24 4 5 5
133
www.honeywell.com/sensing
EN Series
Standard switches
Operating characteristics (except where specified otherwise )
Operating force max. (OF): 26,69 N to 53,38 N [6 lb to 12 lb]
Low 13,3 N to 26,7 N [3 lb to 6 lb]
Pretravel max. (PT): 1,02 mm [0.04 in]
Overtravel min. (OT): 6,35 mm [0.25 in]
High 12,7 mm [0.50 in]
Differential travel max. (DT): 0,51 mm [0.020 in]
OPTIONS
Top pin plungers
Leadwire #20 wire gage
1EN1-6/1EN231-6/1EN51-6
72,4
2.85 or
or
57,4
2.26
45,7
1.8
1EN61-6/1EN412-3
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT A MS24331-1 1EN1-6
High shock DPDT A 1EN231-6
Low OF DPDT A 1EN51-6
High OT DPDT A 1EN61-6
Gold contacts DPDT E 1EN412-3
Leadwire #18 wire gage
Housing
height
Housing
Ø
2EN/3EN/4EN Series
Pretravel Differential travel Housing
max. (PT) max. (DT) Height Diameter
2EN 1,27 mm 0,89 mm 38,1 mm 38,1 mm
[0.05 in] [0.035 in] [1.50 in] [1.5 in]
3EN 1,52 mm 0,89 mm 33,3 mm 38,1 mm
[0.06 in] [0.035 in] [1.31 in] [1.5 in]
4EN 1,78 mm 1,14 mm 43,2 mm 38,1 mm
[0.07 in] [0.045 in] [1.70 in] [1.5 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT B MS24331-2 2EN1-6
1 CKT, DB C MS24331-3 3EN1-6
2 CKT, DB C MS24331-4 4EN1-6
Leadwire termination Bottom receptacle
termination
Side receptacle
termination
SEALED SWITCHES
134 www.honeywell.com/sensing
SEALED SWITCHES
EN Series
Standard switches (continued)
Top pin plungers (continued)
Bottom receptacle
MATES WITH
MIL-C-81703,
MS3137E7-50S
OR EQUIVALENT
1EN75-R
MATES WITH
MS3106E-16S-1S
1EN75-R3
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
High shock DPDT D 1EN75-R
High shock DPDT D M8805/65-001 1EN75-R3
Side receptacle
1EN76-R
MATES WITH
MIL-C-81703,
MS3137E7-50S
OR EQUIVALENT
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
High shock DPDT D 1EN76-R
Ball bearing plunger
39,1
1.54 25,4
1.00
UNEF
7,9
0.31
Leadwire #20 wire gage
Housing height: 24,9 mm [0.98 in]
Diameter: 25,4 mm [1.00 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT A 2001EN1-6
Top roller plunger
Leadwire Bottom
receptacle
Leadwire #20 wire gage
Housing height: 24,9 mm [0.98 in]
Diameter: 25,4 mm [1.00 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT A 21EN9-6
Gold contacts DPDT E 21EN108-6
Bottom receptacle
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
High shock DPDT D 21EN75-R1
135
www.honeywell.com/sensing
Leadwire termination
Leadwire termination
SEALED SWITCHES
Rotary roller lever
Leadwire #20 wire gage
Operating force max. (OF): 1,4 N m to 2,8 N m [12 in lb to 25 in lb]
Pretravel max. (PT): 13° ± 3°
Differential travel max. (DT):
Housing height: 53,6 mm [2.11 in]
Diameter: 25,4 mm [1.00 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT D MS21320-1 (CW) 31EN11-6
DPDT D MS21320-2 (CCW) 31EN1-6
Leadwire #18 wire gage
Operating force max. (OF): 1,4 N m to 2,8 N m [12 in lb to 25 in lb]
Pretravel Differential travel Housing
(PT) max. (DT) Height Diameter
32EN 20° ± 4° 6° 68,6 mm [2.70 in] 38,1 mm [1.5 in]
33EN 15° ± 4° 5° 62,0 mm [2.44 in] 38,1 mm [1.5 in]
34EN 15° ± 5° 10° 71,6 mm [2.82 in] 38,1 mm [1.5 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT B MS21320-3 (CW) 32EN11-6
DPDT B MS21320-4 (CCW) 32EN1-6
1CKT DB C MS21320-5 (CW) 33EN11-6
1CKT DB C MS21320-6 (CCW) 33EN1-6
2CKT DB C MS21320-7 (CW) 34EN11-6
2CKT DB C MS21320-8 (CCW) 34EN1-6
Rotary linkage lever, adjustable rod
Leadwire #20 wire gage
Operating force max. (OF): 0,34 N m [3 in lb]
Differential travel max. (DT): 12°
Housing height: 25,4 mm [1.00 in]
Diameter: 25,4 mm [1.00 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT A MS24420-1 41EN1-6
Leadwire #18 wire gage
Operating force max. (OF): 42EN 0,57 N m [5 in lb]
44EN 1,13 N m [10 in lb]
Differential travel Housing
max. (DT) Height Diameter
42EN 12° 42,2 mm [1.66 in] 38,1 mm [1.5 in]
44EN 20° 45,7 mm [1.80 in] 38,1 mm [1.5 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT B MS24420-2 42EN1-6
2 CKT DB C MS24420-4 44EN1-6
136 www.honeywell.com/sensing
EN Series
Miniature switches
Top roller plunger
600EN
Housing
height
Housing Ø
Leadwire #20 wire gage
Housing Height Diameter
622EN 25,4 mm [1.0 in] 17,5 mm [0.69 in]
624EN 30,5 mm [1.20 in] 25,4 mm [1.0 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT F MS27240-3 622EN1-6
Gold contacts DPDT E MS27240-7 622EN222-6
4PDT F MS27240-4 624EN1-6
4PDT E MS27240-8 624EN222-6
SEALED SWITCHES
Miniature type EN switches may meet the demand for smaller size and
lighter weight without sacrificing performance or electrical capacity.
These types are of the same construction, seal, and materials as the
standard size EN switches.
Type 400EN switches are directly interchangeable with their standard size
EN counterpart, yet are smaller in diameter and lighter in weight. The
miniature listing housing is 0.312 in [7,92 mm] smaller in diameter, and
the switch weight 1.2 oz [14,2g] less.
Operating temperature: -55 °C to 85 °C
[-67 °F to 185 °F]
Top pin plunger
Housing
height
Housing
Ø
400EN
Housing
Ø
Housing
height
600EN
400EN 600EN
Leadwire #20 wire gage
Housing Height Diameter
402EN 24,9 mm [0.98 in] 17,5 mm [0.69in]
404EN 30,5 mm [1.20 in] 25,4 mm [1.0 in]
602EN 25,4 mm [1.0 in] 17,5 mm [0.69 in]
604EN 30,5 mm [1.200 in] 25,4 mm [1.0 in]
CIRCUITRY ELECTRICAL MILITARY PART CAT. LISTING
RATING NUMBER
DPDT F MS21321-1 402EN1-6
4PDT F MS21321-2 404EN1-6
DPDT F MS27240-1 602EN1-6
Gold contacts DPDT E MS27240-5 602EN222-6
4PDT F MS27240-2 604EN1-6
Gold contacts 4PDT E MS27240-6 604EN222-6
137
www.honeywell.com/sensing
SEALED SWITCHES
OPTIONS
Top pin plunger
1HE1-6
602HE1-6
604HE1-6 dimensions as 602HE1-6 except: Ø 25,4 mm [1.00 in]
Height 30,5 mm [1.20 in]
FEATURES ELECTRICAL CONTACT MILITARY PART CAT. LISTING
RATING NUMBER
3 x leadwires,
gold contacts C SPDT 1HE222-6
B DPDT MS8805/80-01 1HE1-6
Gold contacts C DPDT 602HE106-6
A DPDT 602HE1-6
12 x leadwires A 4PDT 604HE1-6
Top roller plunger
622HE1-6
624HE1-6 dimensions as 622HE1-6 except: Ø 25,4 mm [1.00 in]
Height 30,5 mm [1.20 in]
FEATURES ELECTRICAL CONTACT MILITARY PART CAT. LISTING
RATING NUMBER
A DPDT 622HE1-6
12 x leadwires A 4PDT 624HE1-6
HE Series
Hermetically Sealed, Limit
Switches
The HE Series Hermetically-sealed Limit Switch meets hermetic sealing as
defined in MIL-S-8805, Symbol 5. The HE Series features true hermetic
sealing (metal-to-metal, glass-to metal construction), aimed at providing
maximum sealing effectiveness for exceptionally long periods of time
regardless of constant changes in atmospheric pressures and
temperatures.
Housing material: Stainless Steel
Sealing: Hermetic MIL-S-8805, design symbol
5
Operating temperature: -55 °C to 125 °C [-67 °F to 257 °F]
Termination: Leadwire (x 6)
Operating force max. (OF):
1HE Series 26,69 N to 53,38 N [6 lb to 12 lb]
600HE Series 22,2 N to 53,38 N [5 lb to 12 lb]
Pretravel max. (PT): 1,02 mm [0.04 in]
Overtravel min. (OT): 1HE Series 6,35 mm [0.25 in]
600HE Series 3,18 mm [0.12 in]
Differential travel max. (DT): 0,51 mm [0.02 in]
Contacts: Electrical ratings A/B Silver
Electrical rating C Gold
Electrical ratings: A 7 A res., 5 A ind., 28 Vdc
B 5 A res., 3 A ind., 28 Vdc
C 1 A res., 0.50 A ind., 28 Vdc
Switching options:
SPDT Single Pole, Double Throw
DPDT Double Pole, Double Throw
1
4
2
3
5
6
4PDT 4 Pole, Double Throw
1
4
2
3
5
6
7
10
8
9
11
12
138 www.honeywell.com/sensing
SEALED SWITCHES
HR Series
Hermetically Sealed, High
Temperature, Limit Switches
The HR Series high temperature, hermetically sealed switch is sealed as
defined in MIL-S-8805, Symbol 5. The HR Series combines maximum
sealing, high temperature (315 °C [600 °F]) capabilities and rugged,
heavy duty, corrosion-resistant construction aimed at providing reliable
switching in the most demanding applications.
Housing material: Stainless Steel
Sealing: Hermetic MIL-S-8805, design symbol 5
Operating temperature: -65 °C to 315 °C
[-85 °F to 600 °F]
Termination: Screw or leadwire [1,83 m, 6 ft]
Operating force max. (OF): 26,69 N to 53,38 N [6 lb to 12 lb]
Pretravel max. (PT): 1,27 mm [0.05 in]
Overtravel min. (OT): 6,35 mm [0.25 in]
Differential travel max. (DT): 0,38 mm [0. 01 in]
Contacts: Silver
Electrical rating: 5 A, 28 Vdc
Switching options:
SPDT Single Pole, Double Throw
DPDT Double Pole, Double Throw
1
4
2
3
5
6
OPTIONS
Top pin plunger
Screw termination
CONTACT MILITARY PART CAT. LISTING
NUMBER
DPDT MS24594-1 12HR1-S
Leadwire termination
CONTACT MILITARY PART CAT. LISTING
NUMBER
SPDT 12HR8-6
Top roller plunger, parallel
Screw termination
CONTACT MILITARY PART CAT. LISTING
NUMBER
DPDT 22HR1-S
139
www.honeywell.com/sensing
TL Series
Environment Sealed
Toggle Switches
The TL Series are military-grade design and environment-proof sealed
toggle switches, qualified to MIL-S-3950. A large selection of circuitries,
lever designs, and electrical terminations are available, with silver or gold
plated contacts to meet a variety of electrical load requirements. They
have high strength, temperature resistant, non-tracking case material.
For options other than those shown below, contact Honeywell for more
information.
IWTS (Integrated Wire Termination System) option
IWTS provides you with a reliable, completely serviceable unit which meets
MIL-S-3950 requirements. IWTS improves maintainability since wiring
bundles need not be disturbed. Leads are quickly and easily assembled or
removed with an insert-extract tool.
A unique three-rib (grommet style) elastomer seal protects the lead
connections without potting. There are no exposed metal terminals.
Versions are available that will accept No.16 wire with M39029/1-102
contact pins or No. 20 wire with M39029/1-101 contact pins. Connections
are resistant to shock, vibration, and high pulling force.
Approvals: UL, CSA, CE
Sealing: MIL-S-3950
Operating temperature: -65 °C to 71 °C
[-85 °F to 160 °F]
Mounting: Bushing 15/32 in
Termination: Solder, Screw,
IWTS (14-16 Gage and 16-20 Gage)
Contacts: Silver cadmium oxide or gold (gold where indicated)
Electrical ratings (Resistive load):
Values below are based on previous Honeywell testing and opinion. See
MIL-S-3950 for Military specified values.
A0.5 A to 15 A at 0.5 Vac to 277 Vac|0.75 A at 115 Vdc|
0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A at 250 Vdc
B0.5 A to 15 A at 0.5 Vdc to 28 Vdc|0.75 A at 115 Vdc|
0.5 A to 10 A at 0.5 Vac to 277 Vac|0.5 A at 250 Vdc
C0.75 A at 115 Vdc|0.5 A to 20 A at 0.5 Vdc to 28 Vdc|
0.5 A to 15 A at 0.5 Vac to 277 Vac|0.5 A at 250 Vdc
D0.5 A to 18 A at 0.5 Vdc to 28 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac|
0.5 A at 250 Vdc|0.75 A at 115 Vdc
E0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A to 15 A at 0.5 Vac to 277 Vac|
0.5 A at 250 Vdc|0.75 A at 115 Vdc
F0.75 A at 115 Vdc|0.5 A at 250 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac|
0.5 A to 18 A at 0.5 Vdc to 28 Vdc
UL/CSA Rating Code:
L191: 15 A-125, 250, 277 Vac; 1/2 Hp-125 Vac;
1 Hp-250, 277 Vac; 5 A-120 Vac “L”
L192: 10 A-125, 250, 277 Vac; 1/4 Hp-125 Vac;
1/2 Hp-250, 277 Vac; 3 A-125 Vac “L”
Application Note:
Honeywell does not recommend the use of silver cadmium oxide switch
contacts in non-arcing loads. Non-arcing loads are generally loads less than
12 V and/or 0.5 A. TL switches use silver cadmium oxide contact.
If you have specific questions, contact Honeywell.
MANUAL SWITCHES
IWTS type -
1 and 2 pole
Locking lever
Standard lever - 1, 2 and 4 pole
140 www.honeywell.com/sensing
MANUAL SWITCHES
Standard lever
IWTS (Integrated Wire Termination System)
Locking lever
Terminal circuit identification
One pole
Two pole
Four pole
Panel cutout
With locking ring Without locking ring
Note:
1,4 mm/.06in MIN DEEP TO ACCOMMODATE LOCKING
RING.15PA87 PANEL SEAL REQUIRES BLIND HOLE
TO ENSURE SEAL INTEGRITY
Lever locking configurations
Relates to bold digit in Cat. Listing (part number)
AD E
FGK
Locked In
3 Positions
Locked In
Extreme Position
(Opposite Keyway)
Locked In
Extreme Position
(Keyway Side)
Locked In
Center and
Extreme Position
(Opposite Keyway)
Locked In
Center Position
Locked Out of
Center Position
141
www.honeywell.com/sensing
2 Position Switching options/Operating action:
SPST Single Pole, SingleThrow
1
Keyway
Position
Opposite
Keyway
Position
2323 ONOFF
2
Keyway
Momentary
Position
Opposite
Keyway
Position
12 12
ON OFF
SPDT Single Pole, Double Throw
3
Keyway
Position
Opposite
Keyway
Position
1231 32
ON ON
4
Keyway
Momentary
Position
Opposite
Keyway
Position
1231 32
ON ON
DPST Double Pole, Single Throw
5
Keyway
Position
Opposite
Keyway
Position
23 32
65 65
OFF ON
6
Keyway
Momentary
Position
Opposite
Keyway
Position
12 12
54 45
ON OFF
DPDT Double Pole, Double Throw
7
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
4PST 4 Pole, Single Throw
8
Keyway
Position
Opposite
Keyway
Position
3 2 3 2
6 5 6 5
9 8 9 8
12 11
OFF 12 11
ON
4PDT 4 Pole, Double Throw
9
Keyway
Position
Opposite
Keyway
Position
3 2 1 3 2 1
6 5 4 6 5 4
9 8 7 9 8 7
12 11 10
ON 12 11 10
ON
10
Keyway
Momentary
Position
Opposite
Keyway
Position
3 2 1 3 2 1
6 5 4 6 5 4
9 8 7 9 8 7
12 11 10
ON 12 11 10
ON
TL Series
2 position switches
Standard lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
SPST 1 A L191 MS24523-22 1TL1-2
SPST 2 B L192 MS24523-30 1TL1-6
SPDT 3 A L191 MS24523-23 1TL1-3
SPDT 4 B L192 MS24523-26 1TL1-8
2 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
DPST 5 C L191 MS24524-22 2TL1-2
DPST 6 D L192 MS24524-30 2TL1-6
2 pole, solder terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
DPST 5 C L191 MS27735-22 12TL1-2
DPDT 7 C L191 MS27735-23 12TL1-3
2 pole, ITWS (16-20 Gage)
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
DPST 5 C L191 MS27785-22 102TL2-2
DPDT 7 C L191 MS27785-23 102TL2-3
4 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
4PST 8 E L191 MS24525-22 4TL1-2
4PDT 9 E L191 MS24525-23 4TL1-3
4PDT 10 F L192 MS24525-26 4TL1-8
Locking lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
SPST 1 A L191 MS24658-22D 1TL1-2D
SPST 1 A L191 MS24658-22G 1TL1-2G
SPDT 3 A L191 MS24658-23D 1TL1-3D
SPDT 3 A L191 1TL150-3D[1]
SPDT 4 B L192 MS24658-26F 1TL1-8F
2 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
DPST 5 C L191 MS24659-22D 2TL1-2D
4 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
4PDT 9 E L191 MS24660-23D 4TL1-3D
[1] FAA-PMA approved, white resilient cap on lever
MANUAL SWITCHES
142 www.honeywell.com/sensing
MANUAL SWITCHES
3 Position Switching options/Operating action:
SPST Single Pole, SingleThrow
11
Keyway
Position
Opposite
Keyway
Position
2323 ONOFF
12
Keyway
Momentary
Position
Opposite
Keyway
Position
12 12
ON OFF
SPDT Single Pole, Double Throw
13
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
14
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
15
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
ON OFF ON
DPST Double Pole, Single Throw
16
Center
Maintained
Position
Opposite
Maintained
Keyway
Position
3 2 3 2
6 5 6 5
DPDT Double Pole, Double Throw
17
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
18
Keyway
Momentary
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
19
Center
Maintained
Position
Opposite
Maintained
Keyway
Position
3 2 1 3 2 1
6 5 4 6 5 4
20
Keyway
Maintained
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
21
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Momentary
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
22
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
23
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
24
Keyway
Maintained
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
25
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
6546 45645
ON OFF ON
26
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Position
1231 32132
6546 45645
ON OFF ON
TL Series
3 position switches
Standard lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
SPST 11 A L191 MS24523-24 1TL1-21
SPST 12 B L192 MS24523-28 1TL1-61
SPDT 13 A L191 MS24523-21 1TL1-1
SPDT 14 B L192 MS24523-31 1TL1-5
SPDT 15 B L192 MS24523-27 1TL1-7
1 pole, ITWS (14-16 Gage)
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
SPST 11 A L191 MS27722-24 101TL1-21
2 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
DPST 16 C L191 MS24524-24 2TL1-21
DPDT 17 C L191 MS24524-21 2TL1-1
DPDT 20 C L191 MS27407-4 2TL1-10
DPDT 24 C L191 MS27407-1 2TL1-12
DPDT 17 C L191 MS24524-23 2TL1-3
DPDT 26 D L192 MS24524-31 2TL1-5
DPDT 22 D L192 MS27407-5 2TL1-50
DPDT 23 D L192 MS27407-2 2TL1-56
DPDT 25 D L192 MS24524-27 2TL1-7
DPDT 21 D L192 MS27407-6 2TL1-70
DPDT 18 D L192 MS24524-26 2TL1-8
4 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
4PDT 27 F L192 MS24525-27 4TL1-7
Locking lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
SPDT 13 A L191 MS24658-21A 1TL1-1A
SPDT 15 B L192 MS24658-27E 1TL1-7E
2 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA MILITARY PART CAT. LISTING
ACTION RATING RATING NUMBER
DPDT 17 C L191 MS24659-21A 2TL1-1A
DPDT 20 C L191 MS27408-4A 2TL1-10A
DPDT 17 C L191 MS24659-23D 2TL1-3D
DPDT 17 C L191 MS24659-23G 2TL1-3G
DPDT 19 C L191 MS24659-33K 2TL1-31K
DPDT 21 D L192 MS27408-6E 2TL1-70E
DPDT 18 D L192 MS24659-26F 2TL1-8F
3 Position Switching options/Operating action (continued)
4PDT 4 Pole, Double Throw
27
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
6546 45645
ON OFF ON
9879 78978
12 11 10 12 11 10 12 11 10
143
www.honeywell.com/sensing
TW Series toggle switches are miniature, military grade design and
environment-proof sealed. With silver or gold contacts to meet a variety of
electrical load requirements, options available include IWTS (integrated wire
termination system) versions, a large selection of circuitries, electrical
terminations, lever, and bushing designs. Contact Honeywell for more
information.
Sealing: MIL-S-83731(1TW1-3 not sealed)
Operating temperature: -65 °C to 71 °C
[-85 °F to 160 °F]
Mounting: Bushing 15/32 in or 1/4 in
Termination: Solder
Contacts: Fine silver or gold (gold where indicated)
Electrical ratings* (Resistive load): 0.1 A to 5.0 A at 0.5 Vac to 115 Vac|
0.1 A to 5.0 A at 0.5 Vdc to 28 Vdc
* Values are based on previous Honeywell testing and opinion. See
MIL-S-83731
for Military specified values.
Standard lever, 15/32
in bushing
Locking lever, 15/32
in bushing
Panel cutout, 15/32
in bushing
With locking ring
Note:
1,1 mm/.05 in min. deep to accommodate locking ring.
For switches using panel seal, do not allow thru hole
mounting.
Without locking ring
Standard lever, 1/4
in bushing
Panel cutout, 1/4
in bushing
Without locking ring With locking ring
Special design - black button
2,5
(0.10)
Ø 1,78
(0.07)
15,60
(0.575)
Max.
13,59
(0.535)
Max.
18,80
(0.740)
Max.
11,94
(0.470)
12,70
(0.50)
2,54
(0.100)
Min.
Keyway
12,95 (0.51)
Shoulder
on bushing
Ø
18,03
(0.71) Max.
13,335
(0.525)
Max.
Button
Terminal circuit identification
Standard,
1/4 in bushing
Standard
15/32 in
bushing
Locking
TW Series
Environment Sealed,
Miniature Toggle Switches
MANUAL SWITCHES
144 www.honeywell.com/sensing
MANUAL SWITCHES
TW Series
2 position switches
Standard lever
CIRCUITRY OPERATING MILITARY PART CAT. LISTING
ACTION NUMBER
SPST 1 MS27718-22-1 11TW1-2
Gold plated contacts SPST 1 11TW8-2
SPDT 2 MS27718-23-1 11TW1-3
Gold plated contacts SPDT 2 11TW8-3
DPDT 3 MS27719-23-1 12TW1-3
Gold plated contacts DPDT 2 12TW8-3
Solder T2 type DPDT 3 12TW75-3
Standard lever, unsealed
CIRCUITRY OPERATING MILITARY PART CAT. LISTING
ACTION NUMBER
Bushing 1/4 in SPDT 2 MS27716-23-1 1TW1-3
Locking lever
CIRCUITRY OPERATING MILITARY PART CAT. LISTING
ACTION NUMBER
SPDT 2 MS27720-23-1D 11TW1-3D
DPDT 3 MS27721-23-1D 12TW1-3D
2 Position Switching options/Operating action:
SPST Single Pole, Single Throw
1
Keyway
Position
Opposite
Keyway
Position
2323 ONOFF
SPDT Single Pole, Double Throw
2
Keyway
Position
Opposite
Keyway
Position
1231 32
ON ON
DPDT Double Pole, Double Throw
3
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
TW Series
3 position switches
Standard lever
CIRCUITRY OPERATING MILITARY PART CAT. LISTING
ACTION NUMBER
SPDT 6 MS27718-27-1 11TW1-7
Gold plated contactsSPDT 5 11TW8-5
Gold plated contactsSPDT 6 11TW8-7
DPDT 7 MS27719-21-1 12TW1-1
DPDT 10 MS27753-39 12TW1-50
DPDT 8 MS27719-27-1 12TW1-7
DPDT 9 MS27753-40 12TW1-70
Gold plated contactsDPDT 8 12TW8-7
Solder T2 type DPDT 8 12TW75-7
Locking lever
CIRCUITRY OPERATING MILITARY PART CAT. LISTING
ACTION NUMBER
SPDT 4 MS27720-21-1L 11TW1-1L
DPDT 10 MS27754-39M 12TW1-50M
Special design lever - black button
CIRCUITRY OPERATING MILITARY PART CAT. LISTING
ACTION NUMBER
DPDT 7 12TW29-1
DPDT 8 12TW29-7
3 Position Switching options/Operating action:
SPDT Single Pole, Double Throw
4
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
5
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
6
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
ON OFF ON
DPDT Double Pole, Double Throw
7
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
6546 45645
ON OFF ON
8
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
6546 45645
ON OFF ON
9
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Momentary
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
10
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
Lever locking configurations
Relates to bold digit in Cat. Listing (part number)
DL M
Locked Out of
Center Position
Locked In
Extreme Position
(Keyway Side)
Locked Out of
and Into
Extreme Position
(Opposite Keyway)
145
www.honeywell.com/sensing
AT Series
Toggle Switch Assemblies
The AT Series provides multi-pole (2, 4, 6, 8 &10) toggle switches that
contain precision basic switches which conserve space and weight. The AT
Series offers a standard lever design along with lever-locking mechanisms
that are sometimes required to prevent inadvertently actuating the toggle
lever when it is not desired to do so. The lever-locking mechanisms require
that the toggle lever must be pulled approximately 2,3 mm [0.09 inches]
to change the position. Other variations include different toggle lever
designs/styles, circuitry variation, toggle lever to bushing seals, etc. The
60AT Series offers qualified versions that meet MIL-S-8805/98
requirements. To find out more about the AT Series variations that are
available, contact Honeywell or visit www.honeywell.com/sensing.
Sealing: MIL-S-8805/98
Switching options/Operating action:
SPDT Single Pole, Double Throw
Maintained Maintained
NC COM NO
ON NC COM NO
ON
4PDT, 2 Position 4 Pole, Double Throw
Keyway
Maintained
Opposite
Keyway
Maintained
NC COM NO NC COM NO
NC COM NO
NC COM NO
NC COM NO
ON NC COM NO
OFF
NC COM NO
NC COM NO
4PDT, 3 Position 4 Pole, Double Throw
Keyway
Momentary
Opposite
Keyway
Momentary
NC COM NO NC COM NO
NC COM NO
NC COM NO
NC COM NO
ON NC COM NO
ON
NC COM NO
NC COM NO
Center
Maintained
NC COM NO
NC COM NO
ON
NC COM NO
NC COM NO
Electrical ratings (Resistive load):
Values below are based on previous Honeywell testing and opinion. See
MIL-S-8805/98 for Military specified values.
A0.1 A to1.0 A @ 0.5 Vdc to 28 Vdc
0.1 A to 1.0 A @0.5 Vac to 115 Vac
B0.1 A to 7.0 A @ 0.5 Vdc to 28 Vdc
Pull-to-unlock
Standard
MANUAL SWITCHES
146 www.honeywell.com/sensing
MANUAL SWITCHES
AT Series
2 toggle positions
Standard lever
SPDT
40˚ Approx. Total Travel
19,80
(0.78) 9,525
(0.375)
Ø 3,96 (0.156)
1/4-40 UNS
Thread
Hex nut
9,40
(0.37)
16,0
(0.63)
21,08
(0.83)
16,66
(0.656)
Electrical rating: A
Mounting: Bushing ¼ in
TERMINATION CAT. LISTING
Gold contacts Solder T type 6AT124-T
4PDT
17,0
0.67
6,096
0.024 Ø
17,27
0.68
Electrical rating: B
Mounting: Bushing 15/32 in
TERMINATION CAT. LISTING
Silver contacts/FAA-PMA approved Quick Connect 64AT22-3
AT Series
3 toggle positions
Locking lever
4PDT
17,0
0.67
Electrical rating: A
Mounting: Bushing 15/32 in
TERMINATION CAT. LISTING
Gold contacts/FAA-PMA approved H58 64AT34-7E
Panel Cutout
1
/
4
in Bushing
15
/
32
in Bushing
147
www.honeywell.com/sensing
ET Series
Toggle Switches
Environmentally sealed, magnetically held toggle switch. A holding coil
replaces mechanical holding mechanism to maintain the toggle in an operate
position. Available with silver or gold contacts to meet a variety of electrical
load requirements.
Sealing: MIL-S-5594
Operating temperature: -65 °C to 71 °C
[-85 °F to 160 °F]
Mounting: Bushing 15/32 in
Termination: Connector MS 27478Y10E35P
Leadwire 1,83 m [6 ft],
#20 wire per MIL-W-5086
Screw 4 x 48 UNF x 0.188
Solder (turret) Plated, use up to #14 wire
Contacts: Silver or gold (gold where indicated)
Switching options/Operating action:
SPDT Single Pole, Double Throw
Opposite
Keyway
Position Keyway
Position
ON
2 1 3 ON
2 1 3
DPDT Double Pole, Double Throw
Opposite
Keyway
Position Keyway
Position
ON
2 1 3 ON
2 1 3
ON
5 4 6 ON
5 4 6
4PDT 4 Single Pole, Double Throw
Momentary
Opposite
Keyway
Position
Mechanically
Maintained
Center
Position
Electrically
Maintained
Keyway
Position
Electrical ratings (Resistive load):
Values below are based on previous Honeywell testing and opinion. See
MIL-S-5594 for Military specified values.
A0.1 A to 4.0 A @ 0.5 Vdc to 28 Vdc
B0.1 A to 7.0 A @ 0.5 Vdc to 28 Vdc
C0.1 A to 5.0 A @ 0.5 Vdc to 28 Vdc
0.1 A to 5.0 A @0.5 Vac to 115 Vac
D0.1 A to 1.0 A @ 0.5 Vdc to 28 Vdc
Solder Leadwire
Screw
Standard Pull-to-unlock
Standard
Pull-to-unlock
MANUAL SWITCHES
148 www.honeywell.com/sensing
MANUAL SWITCHES
ET Series
2 toggle positions
Standard lever
SPDT
Electrical rating: A
Gold contacts D
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Leadwire M5594/1-1 25ET61-6
Leadwire M5594/1-6 25ET64-6
Leadwire M5594/1-4 25ET62-6
Screw M5594/1-3 25ET61-S
Solder T type M5594/1-2 25ET61-T
Gold contacts Solder T type 25ET117-T
DPDT
Electrical rating: A
Gold contacts D
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Solder T type M5594/2-1 26ET61-T
Solder T type M5594/2-2 26ET65-T
Gold (Bifurcated) contacts Solder T type 26ET107-T
Locking lever
SPDT
Electrical rating: A
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Solder T type 25ET1-T-F
Screw 25ET61-S-F
DPDT
Electrical rating: A
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Solder T type 26ET1-T-F
Connector 26ET1-R-F
ET Series
3 toggle positions
Standard lever
DPDT
Electrical rating: B
Gold contacts D
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Solder T type M5594/3-1 27ET61-T
Gold contacts Solder T type 27ET71-T
4PDT
Electrical rating: C
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Side exit metal tube Leadwire 29ET3
Locking lever
DPDT
Electrical rating: B
Gold contacts D
TERMINATION MILITARY PART CAT. LISTING
NUMBER
Leadwire 27ET2-6-E
Solder T type M5594/6-1E 27ET61-T-E
Gold contacts Solder T type 27ET71-T-E
Solder T2 type 27ET118-T2-N
Lever locking configurations
Relates to bold digit in Cat. Listing (part number)
149
www.honeywell.com/sensing
NT Series toggle switches can meet the need for a rugged, cost-effective
toggle switch. Quality construction features include a seal between the
toggle lever and bushing, and between the cover and case. These
switches can be used where panels are subject to splashes, hosedowns,
or outdoor environments. The “Easy-Start” threaded bushing enables
quick alignment of mounting nut to decrease the chance of cross
threading. The panel stand-off with O-ring feature available on some
listings, eliminates the need for behind-the-panel hardware, provides
uniform panel height, and provides a panel to cover seal.
Locking toggle levers prevent accidental toggle movement. The
knobbed, toggle lever must be pulled out to change position.
Approvals: UL, CSA
Sealing: IP 67/68, NEMA 3, 3R, 4, 13
Operating temperature: -40 °C to 71 °C
[-40 °F to 160 °F]
Mounting: Bushing 15/32 in
Termination: Solder, Screw, Quick Connect
Contacts: Silver cadmium oxide (Gold option available)
Electrical ratings (Resistive load):
Values below are based on previous Honeywell testing and opinion.
A0.5 A to 15 A at 0.5 Vac to 277 Vac|0.75 A at 115 Vdc|
0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A at 250 Vdc
B0.5 A to 10 A at 0.5 Vac to 277 Vac|0.5 A to 15 A at 0.5 Vdc to 28
Vdc|
0.5 A at 250 Vdc|0.75 A at 115 Vdc
C0.75 A at 115 Vdc|0.5 A to 20 A at 0.5 Vdc to 28 Vdc|
0.5 A to 15 A at 0.5 Vac to 277 Vac|0.5 A at 250 Vdc
D0.5 A to 18 A at 0.5 Vdc to 28 Vdc|0.5 A to 10 A at 0.5 Vac to 277
Vac|
0.5 A at 250 Vdc|0.75 A at 115 Vdc
E0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.5 A to 15 A at 0.5 Vac to 277
Vac|
0.5 A at 250 Vdc|0.75 A at 115 Vdc
UL/CSA Rating Code:
L191: 15 A-125, 250, 277 Vac; 1/2 Hp-125 Vac;
1 Hp-250, 277 Vac; 5 A-120 Vac “L”
L192: 10 A-125, 250, 277 Vac; 1/4 Hp-125 Vac;
1/2 Hp-250, 277 Vac; 3 A-125 Vac “L”
Application Note:
Honeywell does not recommend the use of silver cadmium oxide switch
contacts in non-arcing loads. Non-arcing loads are generally loads less
than 12 V and/or 0.5 A. NT switches use silver cadmium oxide contacts,
but gold contact options are available.
If you have specific questions, contact Honeywell.
NT Series
Sealed Toggle Switches
Flat base,
Panel stand-off
Step base,
Panel stand-off
Step base,
no hardware
Note:
No hardware indicates no mounting nuts, keying washer, lockwasher or
termination screws (if applicable).
MANUAL SWITCHES
150 www.honeywell.com/sensing
MANUAL SWITCHES
Terminal circuit identification
One pole
Two pole
Four pole
Panel cutout
With locking ring Without locking ring
Note:
1,4 mm/.06in MIN DEEP TO ACCOMMODATE LOCKING
RING.15PA87 PANEL SEAL REQUIRES BLIND HOLE
TO ENSURE SEAL INTEGRITY
Lever locking configurations
Relates to bold digit in Cat. Listing (part number)
ADE L
Locked In
3 Positions
Locked Out of
Extreme Position
(Keyway Side)
Locked In
Center Position
Locked Out of
Center Position
G
Locked In
Extreme Position
(Keyway Side)
NT Series, Step base switches
Standard lever
DIM "A"
1 pole 29,5 mm (1.16 in)
2 & 4 pole 34,4 mm (1.35 in)
NOTES:
1. Locking levers have 10,7 mm (0.42 in) Ø
2. Locking ring, lockwasher, 2 hexnuts and
terminal screws are provided unassembled
Panel stand off toggle
To order an NT Series toggle switch with panel stand-off feature, insert “6”
in front of any standard listing.
Example: to order panel stand-off version of standard bushing 1NT1-7, alter
number to 61NT1-7.
AB
1,52 (0.06)
Ø 6,10
(0.24)
17,02
(0.67)
12,45
(0.49) 7,37 (0.29)
DIM "A" DIM "B"
1 pole 29,5 mm (1.16 in) 23,11 mm (0.91 in)
2 pole 34,4 mm (1.35 in) 27,94 mm (1.10 in)
Solder terminals Quick Connect terminals
7,6
0.3
5,3
0.21
3,2
0.12
151
www.honeywell.com/sensing
NT Series, Step base,
2 position switches
Standard lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
SPST 1 A L191 1NT1-2
SPST 2 B L192 1NT1-6
SPDT 3 A L191 1NT1-3
No hardware SPDT 3 A L191 1NT1-3-NH
SPDT 4 B L192 1NT1-8
No hardware SPDT 4 B L192 1NT1-8-NH
1 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
SPST 2 A L191 1NT91-2
1 pole, solder terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
SPST 1 A L191 11NT1-2
SPDT 3 A L191 11NT1-3
2 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
DPST 5 C L191 2NT1-2
DPDT 6 C L191 2NT1-3
No hardware DPDT 6 C L191 2NT1-3-NH
DPDT 7 D L192 2NT1-8
No hardware DPDT 7 D L192 2NT1-8-NH
2 pole, solder terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
DPDT 6 C L191 12NT1-3
4 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
4PDT 8* E L191 4NT1-3
4 pole, solder terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION RATING RATING
4PDT 8* E L191 14NT1-3
Locking lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT.LISTING
ACTION* RATING RATING
SPST 1 A L191 1NT1-2G
SPDT 3 A L191 1NT1-3D
* Operating action 1 to 8
2 Position Switching options/Operating action* (1 to 8):
SPST Single Pole, SingleThrow
1
Keyway
Position
Opposite
Keyway
Position
2323 ONOFF
2
Keyway
Momentary
Position
Opposite
Keyway
Position
12 12
ON OFF
SPDT Single Pole, Double Throw
3
Keyway
Position
Opposite
Keyway
Position
1231 32
ON ON
4
Keyway
Momentary
Position
Opposite
Keyway
Position
1231 32
ON ON
DPST Double Pole, Single Throw
5
Keyway
Position
Opposite
Keyway
Position
23 32
65 65
OFF ON
DPDT Double Pole, Double Throw
6
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
7
Keyway
Momentary
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
4PDT 4 Pole, Double Throw
8
Keyway
Position
Opposite
Keyway
Position
3 2 1 3 2 1
6 5 4 6 5 4
9 8 7 9 8 7
12 11 10
ON 12 11 10
ON
MANUAL SWITCHES
152 www.honeywell.com/sensing
MANUAL SWITCHES
NT Series, Step base,
3 position switches
Standard lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
SPDT 9 A L191 1NT1-1
SPDT 10 B L192 1NT1-5
SPDT 11 B L192 1NT1-7
No hardware SPDT 11 B L192 1NT1-7-NH
SPDT 11 B L191 1NT231-7
Panel stand off SPDT 11 D L192 61NT1-7
1 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
SPDT 11 B L192 1NT91-7
1 pole, solder terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
SPDT 11 B L192 11NT1-7
No hardware SPDT 11 B L192 11NT1-7-NH
2 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
DPDT 12 C L191 2NT1-1
No hardware DPDT 12 C L191 2NT1-1-NH
DPDT 13 C L191 2NT1-10
DPDT 17 D L192 2NT1-5
DPDT 15 D L192 2NT1-50
DPDT 16 D L192 2NT1-7
No hardware DPDT 16 D L192 2NT1-7-NH
DPDT 14 D L192 2NT1-70
DPDT 16 D L192 2NT231-7
Gold contacts/ DPDT 14 D L192 2NT889-70
long lever
2 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
DPDT 16 D L192 2NT91-7
4 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
4PDT 18 E L191 4NT1-1
Locking lever
1 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
SPDT 11 B L192 1NT1-7E
SPDT 11 B L191 1NT20-7E
4 pole, screw terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION** RATING RATING
4PDT 18 E L191 4NT1-1A
**Operating action 9 to 18
3 Position Switching options/Operating action** (9 to 18):
SPDT Single Pole, Double Throw
9
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
10
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
11
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
ON OFF ON
DPDT Double Pole, Double Throw
12
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
13
Keyway
Maintained
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
14
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Momentary
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
15
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
16
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
6546 45645
ON OFF ON
17
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Position
1231 32132
6546 45645
ON OFF ON
4PDT 4 Pole, Double Throw
18
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
6546 45645
ON OFF ON
9879 78978
12 11 10 12 11 10 12 11 10
153
www.honeywell.com/sensing
NT Series, Flat base switches NT Series, Flat base,
2 position switches
Standard lever
1 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
SPST 1 A L191 31NT91-2
SPST 2 B L192 31NT91-6
SPDT 3 A L191 31NT91-3
2 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
DPST 4 C L191 32NT91-2
DPDT 5 C L191 32NT91-3
Locking lever
1 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
DPDT 5 C L191 32NT291-3G
2 Position Switching options/Operating action:
SPST Single Pole, Single Throw
1
Keyway
Position
Opposite
Keyway
Position
2323 ONOFF
2
Keyway
Momentary
Position
Opposite
Keyway
Position
12 12
ON OFF
SPDT Single Pole, Double Throw
3
Keyway
Position
Opposite
Keyway
Position
1231 32
ON ON
DPST Double Pole, Single Throw
4
Keyway
Position
Opposite
Keyway
Position
23 32
65 65
OFF ON
DPDT Double Pole, Double Throw
5
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
MANUAL SWITCHES
154 www.honeywell.com/sensing
MANUAL SWITCHES
NT Series, Flat base,
3 position switches
Standard lever
1 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
SPDT 6 A L191 31NT91-1
SPDT 7 B L192 31NT91-7
2 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
DPDT 8 C L191 32NT91-1
DPDT 10 D L192 32NT91-7
No hardware DPDT 10 D L192 32NT91-7-NH
Locking lever
2 pole, Quick Connect terminals
CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
DPDT 11 D L192 32NT291-5E
DPDT 9 D L192 32NT94-70L
3 Position Switching options/Operating action:
SPDT Single Pole, Double Throw
6
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
7
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
ON OFF ON
DPDT Double Pole, Double Throw
8
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
6546 45645
ON OFF ON
9
Keyway
Momentary
Position
Center
Maintained
Position
Opposite
Keyway
Momentary
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
10
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
6546 45645
ON OFF ON
11
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Position
1231 32132
6546 45645
ON OFF ON
155
www.honeywell.com/sensing
TS Series
Toggle Switches
TS Series switches may be used in applications where manual operation
is desired. Special on-on-on circuitry can also be furnished. They have
2- or 3-position, momentary and maintained action switches with 1- and
2-pole circuitry. Switches have solder, screw or quick-connect
terminations.
Approvals: UL, CSA
Operating temperature: -54 °C to 71 °C
[-65 °F to 160 °F]
Mounting: Bushing 15/32 in
Lever/bushing material: Bright nickel
Termination: Solder, Screw, Quick Connect
Contacts: Silver tin oxide and indium oxide
Electrical ratings* (Resistive load): 0.4 A to 10 A at 126 Vac to 277 Vac|
0.4 A to 20 A at 0.5 Vac to 125 Vac
* Values are based on previous Honeywell testing and opinion.
UL/CSA Rating Code:
L311: 10 A 277 Vac, 20 A 125 Vac; 3/4 Hp-125, 250 Vac
L312: 10 A 277 Vac, 20 A 125 Vac; 11/2 Hp-125, 250 Vac
11TS
One pole
12TS
Two pole
Panel cutout
With locking ringWithout locking ring
MANUAL SWITCHES
156 www.honeywell.com/sensing
MANUAL SWITCHES
TS Series
2 position switches
Standard lever
Screw terminals
CIRCUITRY OPERATING UL/CSA CAT. LISTING
ACTION RATING
SPST 1 L311 11TS15-2
SPST 2 L311 11TS15-6
DPST 4 L312 12TS15-2
DPDT 5 L312 12TS15-3
Quick Connect terminals
CIRCUITRY OPERATING UL/CSA CAT. LISTING
ACTION RATING
SPST 1 L311 11TS95-2
DPDT 5 L312 12TS95-3
Solder terminals
CIRCUITRY OPERATING UL/CSA CAT. LISTING
ACTION RATING
SPDT 3 L311 11TS115-3
Furnished unassembled DPDT 5 L312 12TS115-3
2 Position Switching options/Operating action:
SPST Single Pole, Single Throw
1
Keyway
Position
Opposite
Keyway
Position
2323 ONOFF
2
Keyway
Momentary
Position
Opposite
Keyway
Position
12 12
ON OFF
SPDT Single Pole, Double Throw
3
Keyway
Position
Opposite
Keyway
Position
1231 32
ON ON
DPST Double Pole, Single Throw
4
Keyway
Position
Opposite
Keyway
Position
23 32
65 65
OFF ON
DPDT Double Pole, Double Throw
5
Keyway
Position
Opposite
Keyway
Position
1231 32
6546 45
ON ON
TS Series
3 position switches
Standard lever
Screw terminals
CIRCUITRY OPERATING UL/CSA CAT.
LISTING ACTION RATING
SPDT 6 L311 11TS15-1
SPDT 7 L311 11TS15-7
DPDT 8 L312 12TS15-7
Quick Connect terminals
CIRCUITRY OPERATING UL/CSA CAT.
LISTING ACTION RATING
SPDT 7 L311 11TS95-7
Furnished unassembled DPDT 9 L312 12TS95-10
3 Position Switching options/Operating action:
SPDT Single Pole, Double Throw
6
Keyway
Position Center
Position
Opposite
Keyway
Position
1231 32132
ON OFF ON
7
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
ON OFF ON
DPDT Double Pole, Double Throw
8
Keyway
Momentary
Position Center
Position
Opposite
Keyway
Momentary
Position
1231 32132
6546 45645
ON OFF ON
9
Keyway
Maintained
Position
Center
Maintained
Position
Opposite
Keyway
Maintained
Position
3 2 1 3 2 1 3 2 1
6 5 4 6 5 4 6 5 4
ON ON ON
157
www.honeywell.com/sensing
TP Series
Rocker Switches
Honeywell’s 2 and 3 position, pushbutton action rocker switches are
dust and splash-proof sealed. They can be provided with or without
buttons. The switches are available as flush or panel mount, a large
selection of rocker colors, circuitries and electrical terminations. Versions
are available with silver or gold contacts to meet a variety of electrical
load requirements. For options other than those shown below, contact
Honeywell for more information.
Switching options/Operating action:
2 Position Switches
SPST Single Pole, Single Throw
1
Identification
Lug
Position
Opposite
Identification
Lug
Position
2323 ONOFF
2
Identification
Lug
Momentary
Position
Opposite
Identification
Lug
Position
12 12
ON OFF
SPDT Single Pole, Double Throw
3
Identification
Lug
Position
Opposite
Identification
Lug
Position
123 1 32
ON ON
DPDT Double Pole, Double Throw
4
Identification
Lug
Position
Opposite
Identification
Lug
Position
123 1 32
654 6 45
ON ON
5
Identification
Lug
Momentary
Position
Opposite
Identification
Lug
Position
123 1 32
654 6 45
ON ON
3 Position Switches
SPDT Single Pole, Double Throw
6
Identification
Lug
Momentary
Position Center
Position
Opposite
Identification
Lug
Momentary
Position
1231 32132
ON OFF ON
DPDT Double Pole, Double Throw
7
Identification
Lug
Momentary
Position Center
Position
Opposite
Identification
Lug
Momentary
Position
1231 32132
6546 45645
ON OFF ON
Approvals: UL, CSA, CE
Operating temperature: -54 °C to 71 °C
[-65 °F to 160 °F]
Mounting: Above Panel and Flush Panel
Termination: Screw
Contacts: Silver cadmium oxide
Electrical ratings (Resistive load):
Values below are based on previous Honeywell testing and opinion.
A0.5 A to 18 A at 0.5 Vdc to 28 Vdc|0.5 A to 10 A at 0.5 Vac to 277 Vac|
0.75 A at 115 Vdc|0.5 A at 250 Vdc
B0.5 A to 20 A at 0.5 Vdc to 28 Vdc|0.75 A at 115 Vdc|
0.5 A at 250 Vdc|0.5 A to 15 A at 0.5 Vac to 277 Vac
C0.5 A to 10 A at 0.5 Vac to 277 Vac|0.75 A at 115 Vdc|
0.5 A at 250 Vdc|0.5 A to 15 A at 0.5 Vdc to 28 Vdc
UL/CSA Rating Code:
L191: 15 A-125, 250, 277 Vac; 1/2 Hp-125 Vac;
1 Hp-250, 277 Vac; 5 A-120 Vac “L”
L192: 10 A-125, 250, 277 Vac; 1/4 Hp-125 Vac;
1/2 Hp-250, 277 Vac; 3 A-125 Vac “L”
Application Note:
Honeywell does not recommend the use of silver cadmium oxide switch
contacts in non-arcing loads. Non-arcing loads are generally loads less than
12 V and/or 0.5 A. TP switches use silver cadmium oxide contacts, but gold
contact options are available.
If you have specific questions, contact Honeywell.
MANUAL SWITCHES
158 www.honeywell.com/sensing
MANUAL SWITCHES
Above panel mounting
Panel cutout
Flush panel mounting
Terminals
Single pole
Double pole
2 Position
Flush Panel Mount
BUTTON CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
Translucent SPST 2 C L192 1TP1-6
No SPST 1 B L191 1TP8-2
No SPDT 3 B L191 1TP8-3
Above Panel Mount
BUTTON CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
Translucent DPDT 5 A L192 2TP216-8
No DPDT 4 B L191 2TP7-3
Button Options
Buttons are removable and interchangeable.
They measure 22,1 mm x 37,1 mm [0.87 in x 1.46 in].
COLOUR CAT. LISTING
Translucent 12PA6
Transparent 12PA4
White* 12PA5-W
Yellow* 12PA5-Y
Black* 12PA5-BK
Green* 12PA5-G
Red* 12PA5-R
Blue* 12PA5-BL
* Opaque
3 Position
Flush Panel Mount
BUTTON CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
Transparent SPDT 6 C L192 1TP12-7
Translucent SPDT 6 C L192 1TP201-7
No SPDT 6 C L192 1TP8-7
Transparent DPDT 7 A L192 2TP12-7
Translucent DPDT 7 A L192 2TP1-7
Above Panel Mount
BUTTON CIRCUITRY OPERATING ELECTRICAL UL/CSA CAT. LISTING
ACTION RATING RATING
Translucent DPDT 7 A L192 2TP216-7
159
www.honeywell.com/sensing
MANUAL SWITCHES
The FR Series illuminated and non-illluminated full-size sealed rocker
switches offer enhanced design flexibility and set new standards for both
performance and reliability. The switches are designed to fit industry
standard mounting holes of 44,0 mm x 22,0 mm [1.734 in x 0.867 in]
and offer a variety of switch and lamp circuit combinations.
Approvals: UL, CSA
Mechanical life: 250,000 cycles minimum
Electrical life: 50,000 cycles (mom.); 100,000 cycles (maint.)
Sealing: IP 67
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Termination style: 6,35 mm x 0,81 mm [0.25 in x 0.032 in]
quick connect tabs
FR Series
Sealed Rocker Switches
OPTIONS
FRN SERIES
One pole
CIRCUITRY (POS. 3, 2, 1) BEZEL/ACTUATOR COLOR CAT. LISTING
Off, None, On Black/Black FRN91-12BB
Off, None, On (Mom.) Black/Black FRN91-16BB
Off (Mom.), None, On Black/Black FRN91-14BB
On, None, On Black/Black FRN91-13BB
On (Mom.), None, On Black/Black FRN91-18BB
On, Off, On Black/Black FRN91-11BB
On (Mom.), Off, On Black/Black FRN91-15BB
On (Mom.), Off, On (Mom.) Black/Black FRN91-17BB
Two poles
CIRCUITRY (POS. 3, 2, 1) BEZEL/ACTUATOR COLOR CAT. LISTING
Off, None, On Black/Black FRN91-22BB
Off, None, On (Mom.) Black/Black FRN91-26BB
Off (Mom.), None, On Black/Black FRN91-24BB
On, None, On Black/Black FRN91-23BB
On (Mom.), None, On Black/Black FRN91-28BB
On, Off, On Black/Black FRN91-21BB
On (Mom.), Off, On Black/Black FRN91-25BB
On (Mom.), Off, On (Mom.) Black/Black FRN91-27BB
160 www.honeywell.com/sensing
OPTIONS
FRL SERIES
Two poles, Illumination Style C, 12 V
CIRCUITRY (POS. 3, 2, 1) LAMP/LAMP LENS/LENS CAT. LISTING
Off, None, On Green/Amber Large white trans./White bar FRL91-22CGA3-BB79
On, None, On Green/Green Large white trans./White bar FRL91-23CGG3-BB79
On, Off, On Green/Green Large white trans./Large white trans. FRL91-21CGG3-BB77
On (Mom.), Off, On (Mom.) Green/Green Large white trans./Large white trans. FRL91-27CGG3-BB77
MANUAL SWITCHES
Accessories
DESCRIPTION CAT. LISTING
Rocker Boot FR-01
161
www.honeywell.com/sensing
SR Series
Sealed Rocker Switches
OPTIONS
SRN SERIES
One pole
CIRCUITRY (POS. 3, 2, 1) BEZEL/ACTUATOR COLOR CAT. LISTING
Off, None, On Black/Black SRN91-12BB
Off, None, On (Mom.) Black/Black SRN91-16BB
Off (Mom.), None, On Black/Black SRN91-14BB
On, None, On Black/Black SRN91-13BB
On (Mom.), None, On Black/Black SRN91-18BB
On, Off, On Black/Black SRN91-11BB
On (Mom.), Off, On Black/Black SRN91-15BB
On (Mom.), Off, On (Mom.) Black/Black SRN91-17BB
Two poles
CIRCUITRY (POS. 3, 2, 1) BEZEL/ACTUATOR COLOR CAT. LISTING
Off, None, On Black/Black SRN91-22BB
Off, None, On (Mom.) Black/Black SRN91-26BB
Off (Mom.), None, On Black/Black SRN91-24BB
On, None, On Black/Black SRN91-23BB
On (Mom.), None, On Black/Black SRN91-28BB
On, Off, On Black/Black SRN91-21BB
On (Mom.), Off, On Black/Black SRN91-25BB
On (Mom.), Off, On (Mom.) Black/Black SRN91-27BB
MANUAL SWITCHES
The SR Series illuminated and non-illluminated full-size sealed rocker
switches offer enhanced performance in a flexible package. The switches
are available in single or souble pole configurations, have an optional
panel seal, and the SRL Series can be illuminated with square or bar-
shaped lenses.
Approvals: UL, CSA
Mechanical life: 150,000 cycles minimum
Electrical life: 50,000 cycles (mom.); 100,000 cycles (maint.)
Sealing: Dual switch seal certified to IP66/IP68
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Termination style: Offered in both 8 and 10 terminal base options.
AMP and Packard compatible connectors available.
162 www.honeywell.com/sensing
Accessories
DESCRIPTION CAT. LISTING
Connector Housing HRSR-01
DESCRIPTION CAT. LISTING
Connector Housing SR-01
OPTIONS
SRL SERIES
Two poles, Illumination Style A, 12 V
CIRCUITRY (POS. 3, 2, 1) LAMP/LAMP CAT. LISTING
Off, None, On Red/None SRL91-22ARN3-BB9N
Two poles, Illumination Style U, 12 V
CIRCUITRY (POS. 3, 2, 1) LAMP/LAMP LED VOLTAGE CAT. LISTING
On, None, On Red/Red 12 V SRL91-23URR3-BB99
On, Off, On Red/Red 12 V SRL91-21URR3-BB99
On (Mom.), Off, On (Mom.) Red/Red 12 V SRL91-27URR3-BB99
Off, None, On Green/Amber 12 V SRL91-22UGA3-BB99
On, None, On Green/Green 12 V SRL91-23UGG3-BB99
On, Off, On Green/Green 12 V SRL91-21UGG3-BB99
Off, None, On Green/Green 12 V SRL91-22UGG3-BB99
MANUAL SWITCHES
163
www.honeywell.com/sensing
MANUAL SWITCHES
MR Series
Miniature Rocker Switches
OPTIONS
MR SERIES
Non-Illuminated
POLES CIRCUITRY CAT. LISTING
1 N MR93-12BBN
2 N MR93-22BBN
Illuminated, Single Pole
LAMP CIRCUITRY* ACTUATOR COLOR CAT. LISTING
12 V LED 3 Clear Red MR93-122B3
12 V LED 3 Clear Green MR93-124B3
125 V Neon J Clear Red MR93-122BJ
250 V Neon K Clear Amber MR93-121BK
Illuminated, Double Pole
LAMP CIRCUITRY* ACTUATOR COLOR CAT. LISTING
12 V LED 3 Clear Red MR93-222B3
12 V LED 3 Clear Green MR93-224B3
24 V Neon 4 Clear Amber MR93-221B4
These miniature rocker switches offer a variety of aesthetic and
functional options ranging from circuit configurations to ac and dc
ratings. They feature industry standard dimensions, an easy snap-in
mounting method, and offer one-or-two pole switches in numerous
single-throw and double-throw maintained and momentary circuits. The
illuminated and non-illuminated miniature switches are intended to meet
the needs of a wide variety of industries and potential applications. The
silver-alloy contacts will handle a range of electrical loads. The
illuminated products offer LED or neon-style lamps.
Approvals: UL, CSA
Mechanical life: 100,000 cycles minimum
Electrical life: 50,000 cycles
Dielectric strength UL/CSA: 1000 V
Operating temperature: 0 °C to 85 °C [32 °F to 185 °F]
Termination style: 4,75 mm x 0,81 mm tab QC
[0.187 in x 0.032 in] tab QC
* Electrical Ratings (UL/CSA)
N8 A, 125 Vac; 12 A, 125 Vac, ½ HP, 125 Vac - 250 Vac; UL, CSA
1N/A
212 A, 6 V
312 A, 12 V
412 A, 24 V
A12 A, 6 V
C12 A, 12 V
E12 A, 18 V
H12 A, 24 V
J12 A, 125 Vac; UL, CSA
K8 A, 250 Vac; UL, CSA
164 www.honeywell.com/sensing
MRS Series
Miniature Rocker Switches
OPTIONS
MRS SERIES
One pole
CIRCUITRY (POS. 3, 2, 1) BEZEL/ACTUATOR COLOR ELEC. RATING* CAT. LISTING
Off, None, On Black/Black 1 MRS93-12BB
Off, None, On (Mom.) Black/Black 3 MRS93-16BB
Off (Mom.), None, On Black/Black 3 MRS93-14BB
On, None, On Black/Black 1 MRS93-13BB
On (Mom.), None, On Black/Black 3 MRS93-18BB
On, Off, On Black/Black 2 MRS93-11BB
On (Mom.), Off, On Black/Black 2 MRS93-15BB
On (Mom.), Off, On (Mom.) Black/Black 2 MRS93-17BB
These subminiature rocker switches offer a variety of aesthetic and
functional options ranging from circuit configurations to ac and dc
ratings. They feature industry standard dimensions, an easy snap-in
mounting method, and offer one-or-two pole switches in numerous
single-throw and double-throw maintained and momentary circuits.
These non-illuminated switches are often ideal for applications where
there is restricted space behind the panel. It fits in a standard
rectangular cutout and is designed to fit easily and securely. The snap-
action contacts provide the user with a crisp, positive response. A
variety of circuitry choices will appeal to many industry segments.
Approvals: UL, CSA
Mechanical life: 100,000 cycles minimum
Electrical life: 50,000 cycles (mom.); 100,000 cycles (maint.)
Dielectric strength UL/CSA: 1000 V
Operating temperature: 0 °C to 85 °C [32 °F to 185 °F]
Termination style: 4,75 mm x 0,81 mm tab QC
[0.187 in x 0.032 in] tab QC
MANUAL SWITCHES
* Electrical Ratings (UL/CSA)
110 A, 125 Vac; 10 A, 250 Vac; ¼ HP, 125 Vac - 250 Vac
28 A, 125 Vac - 250 Vac; ¼ HP, 125 Vac - 250 Vac
312 A, 125 Vac; 6 A, 250 Vac; ¼ HP, 125 Vac - 250 Vac
165
www.honeywell.com/sensing
Manual Switches and
Pushbuttons
Manual Switches. Designed by industrial designers to achieve balance
between harmonious appearance and ergonomics, AML Advanced
Manual Line has pushbuttons, paddles, and rockers; with LED,
incandescent, and neon illumination. Plus, matching indicators and LED
annunciators. A smaller cousin, MML Minature Manual Line, offers many
AML features in a space-saving size.
Pushbuttons. A wide array of different pushbutton families, many with
lighted display and matching indicators. Includes Series 2, an easily
assembled modular design with many color display/control options; and
compact PB unlighted pushbuttons.
MANUAL SWITCHES AND PUSHBUTTONS
166 www.honeywell.com/sensing
Electrical Data
Solid State:
5, 6 - 16, or
4.5 - 24 Vdc
AML MML
Panel Area 20,5 mm [0.80 in] square
and 20,5 mm x 30 mm
[0.80 in x 1.20 in]
Display 15,0 mm [0.59 in] square and
15,0 mm x 25,0 mm [0.59 in x
0.99 in] buttons
Pushbutton or lens cap (indica-
tor only) buttons with up to
3-section display. Various button
heights. Transmitted, projected,
and dead front hidden legend/color
Illumination Incandescent T-1-3/4 lamps –
6 V, 14 V, and 28 V
LEDs - 2 V, 4 V, 5 V, 10 V, 15 V
Neon lamps – 125 V, 250 V
Behind Panel
Depth (max.) 43,1 mm [1.7 in]
MountingSnap-in individual, strip, matrix,
sub-panel, P.C. board mounting
Termination Solder, quick-connect,
P.C. board, push-on
SealingOptional panel seal
Special
FeaturesAlong with companion rockers and
paddles, provides the most
advanced and complete line of
manual controls available
Electronic
control: Up
to 3 A,
125 Vac
Power Duty:
up to 10 A,
125/250
Vac
Circuitry
Current
sinking
1, 2, and 4
Form C
2 pole,
Form X
Agency
Listings UL, CSA, CDE and CE (selected
products)*
PWB mount: 10,2 mm [0.40 in] square
and 15,2 mm x 10,2 mm [0.60 in x
0.40 in], except 2-pole power duty
paddles and rockers
Pushbuttons: 6,6 mm [0.26 in] square
and 11,7 mm x 6,6 mm [0.46 in x
0.26 in]. Transmitted color
Rockers: Optional lenses for
transmitted color
LEDs - 1.7 V, 2.1 V, 2.2 V, 2.3 V
Incandescent T-1 lamps – 5 V
(other voltages available)
17,0 mm [0.67 in]
Printed wiring board, snap-in strip,
matrix
Printed wiring board, solder,
quick-connect
Solid State:
5 Vdc to 24 Vdc
Electronic
Control: Up
to 1 A,
125 Vac res.
Power Duty
Pushbuttons:
up to 6 A,
250 Vac
res.
Current
sinking
1 or 2
Form C
1 or 2
Form X
UL and CSA
Series 4
21,3 x mm x 26,2 mm
[0.84 in x 1.03 in]
13,5 mm x 18.0 mm [0.53 in x
0.71 in] buttons
Single section display
Transmitted, projected, and
dead front hidden color
Incandescent T-3-1/4 lamps
14 V, 28 V
6,1 mm [2.4 in]
Snap-in individual or strip
mounting; top panel or
sub-panel mounting
Solder, quick-connect,
P.C. board
Can be furnished with locked
button feature for use in public
areas where tampering is a
problem
up to 10 A
1 or 2 Form C
UL, CSA
* For complete international compliance information, contact the 800 number.
MANUAL SWITCHES AND PUSHBUTTONS
167
www.honeywell.com/sensing
Series 2 PB
25,4 mm x 35,8 mm [1.0 in x 1.41 in]
21,8 mm x 34,3 mm [0.86 in x
1.35 in]
21,6 mm x 27,4 mm [0.85 in x
1.08 in] buttons.
1-4 section display
Transmitted and projected color
Incandescent T-1-3/4 lamps,
28 V
83,3 mm [3.28 in]
Snap-in flange mount and units with
mounting barriers for individual
or strip mount
Solder, quick-connect,
and screw terminals
UL, CSA
Depends on type and number of
basic switches
8,1 mm [0.32 in] dia., and other
button sizes
Colored buttons
Threaded bushing
Solder terminals
Panel seal version. Hermetically sealed units
Compact size
Solid state:
5, 6 -16, or
4.5 - 24 Vdc
Electronic
Control: Up
to 3 A,
125 Vac
Power Duty
Pushbuttons:
up to 15 A,
125/250 Vac
Current sinking
2 or 3 positions,
mom. or maint.
1, 2, & 4 Form C,
2 or 3 positions,
mom. or maint.
1 or 2 Form A
2 pos.
maint.
UL, CSA. Some meet MIL-S-8805 and
MIL-STD-1080D
AML
20,5 x mm x 30,5 mm
[0.80 in x 1.20 in]
Paddle:
Full and split
color covers
Snap-in individual, strip,
matrix, sub-panel, P.C.
board mounting
Solder, quick-connect,
P.C. board, push on
Matches display/control options
of AML pushbuttons
UL, CSA, VDC, and CE (selected
products)*
1 A to 20 A, 125 Vac, 250 Vac,
480 Vac, depending on switch
module specified
1 - 4 Form C
2 A to 5 A, 125/250 Vac
1 - 4 Form C
Rocker:
Full and split
color rockers
MANUAL SWITCHES AND PUSHBUTTONS
168 www.honeywell.com/sensing
AML Series
Advanced Manual Line
Switches
In Front of the Panel
Coordinated, attractive appearance. AML features innovations
designed by industrial designers aimed at achieving the best balance of
human factors and aesthetic appearance. Operator height, bezel size,
and the compatability of square and rectangular shapes blend with
other components to harmonize your panel. There’s no visual clutter to
distract from man/machine communication.
This comprehensive line of lighted and unlighted manual controls
features:
Pushbuttons for high and intermediate frequency functions.
Rocker and paddle switches, with two or three positions, for less
frequent control functions.
Plus lighted indicators and annunciators which complement AML’s
universal appeal.
Various controls can be matched with their functions to accommodate
the most natural and efficient habit pattern relfex. Keylock-operated
switches can be used to assure “authorized personnel only” access.
Display flexibility. AML offers a choice of five legend sizes, four button
heights, full or split second display, and illunimation by incandescent
lamps, LEDs or neons. Colors are bright and uniform, providing a
strong definition and good visibility. (Non-illuminated devices have the
same attractive colors.)
Color display options include:
Transmitted color – color can be distinguished whether the lamp is
On or Off.
Dead front – display appears black, until illumination causes legend
and color to appear.
Projected color – white display is diffused with color when
illuminated.
Behind the Panel
AMLs simple, cost-effective design provides many behind-panel benefits
for the designer and installer/user.
Simple to install. They snap in from the panel front individually or in
vertical or horizontal strips; or in subpanel mounted strips and matrices
that can be pre-assembled and pre-wired.
Electrical flexibility. Solid state switches with Hall-effect integrated
circuits interface directly with microprocessors and other logic-level
devices. These ICs were first applied in MICRO SWITCH solid state
keyboards. Today, many MICRO SWITCH products incorporate the Hall-
effect technology to meet a wide range of position sensing and manual
control needs.
Electronic control switches with gold or silver contacts, and 1, 2, or 4
poles, will handle up to three amps. Including an encoded version which
generates different binary coded outputs merely by changing cam-keyed
buttons.
Power-duty switches meet line disconnect application needs with 10-amp
pushbuttons and 15-amp paddle and rocker switches.
Easy to Wire. All AML devices present single-level termination. This
means faster, easier, neater, and more economical wiring. And there is a
choice of solder, quick-connect, push-on, and printed circuit
termination.
Mating Terminals
The .110 x .020 quick-connect/solder terminals (types 2 and 8) are
designed for use with receptacles that comply with the UL standard for
insertion and withdrawal forces. Maximum insertion force is 12 lbs.
max., withdrawal force is 14 lbs. These receptacles are supplied by AMP
Inc., Berg, Augat, Hollingsworth, MALCO, Zierick, and others. Refer to
Thomas Register or the Yellow Pages for the location of your supplier.
Features
Complete selection of pushbutton, rocker, and paddle (toggle type)
switches accommodates different functions and helps promote
operator efficiency.
Solid state, electronic, and power duty control.
Full or split-screen incandescent display switches and indicators
provide vivid transmitted color, projected color (for neutral display
when unlit), and dead front (hidden color).
Wide-angle visibility LED and line voltage neon display switches and
indicators.
Annunciators back lighted by LEDs enable high density message
display.
Keylock switches available for controlled access applications.
All AML terminations at the same shallow depth (43,1 mm [1.7 in])
for convenient wiring or PC board termination.
Snap-in surface mount or sub-panel (hidden bezel) mount with
mounting hardware.
Pad-printed legends with a clear polyurethane overcoat available in a
choice of five standard sizes.
Metric design for worldwide acceptance.
UL recognized, CSA certification.
Selected listings are certifed by VDE and CE. (For compliance status,
contact the 800 number).
Honeywell’s AML Advanced Manual Line combines functional flexibility
with electrical versatility to provide a broad range of options to choose
from.
Easy to Relamp. Relamping of T-1-3/4 incandescent AML91 lamps is
accomplished from the front of the panel without tools. (AML92 T-1-3/4
LEDs can be added in the same manner.
Full Guard Bezel Option. As an alternative to standard height bezels
(1,5 mm [0.6 in]), pushbutton switches can be furnished with full-guard
bezels extending 5,0 mm [0.19 in] from the mounting surface. In the
free position, standard buttons are flush will full-guard bezels.
The raised bezel guards against accidental operation by someone leaning
against or dropping something on a control console.
High Intensity LEDs for Full-face AML Lighted Display
AML 92 Series
Full-face illumination for high visitiblity lighted colors.
Advanced illumination technology combines high-intensity LED in
standard T-1-3/4 wedge base lamp package.
Easy plug-in installation in AML lighted switches and indicators.
Low operating temperature permits high density, continuous
operation with minimal heat build up.
AML92 Series LEDs have a quad chip assembled in a T-1-3/4 wedge
base lamp package. They provide full-face illumination when used with
lighted pushbutton, rocker and paddle switches, or indicators equipped
with incandescent lamp sockets.
MANUAL SWITCHES AND PUSHBUTTONS
169
www.honeywell.com/sensing
AML Series, continued
Approvals: UL (E53576), CSA (LR4442)
Electromechanical Life*
Pushbuttons - Momentary 1,000,000
Pushbuttons - Alternate 25,000
Rockers 25,000
Paddles 25,000
*95% survival
AML10 Series
AML10 Series Electrical Data
Electrical Characteristics Absolute Maximum Rating4
Output Switching Time
Leakage Max. Voltage
Integrated Supply Output Current Rise Fall Supply Externally Loads
Circuit Current Voltage max. 10% to 90% to Voltage Applied to to Storage
Function (max.) (Operated) (Released) 90% 10% (Vs) Output Output Temperature
5 Vdc 3.5 mA +0.4 V 2.0 µA 1.0 µs 1.0 µs -0.5 Vdc to -0.5 V min. 20 mA -40 °C to
Sinking1(released) (sinking (sinking (sinking 7.0 Vdc 15 V max. (sinking) 65 °C
6.5 mA 8 mA) 8 mA) 8 mA) 0 °C to 65 °C (off condition) [-40 °F to
(operated - [32 °F to 149 °F] 149 °F]
no load)
6 Vdc to 16 Vdc 6.5 mA @ +0.4 V 2.0 µA 1.5 µs 0.5 µs -1.2 Vdc to 20 Vdc max. in 40 mA -40 °C to
Sinking26 Vdc, (sinking (sinking (sinking +20 Vdc off condition only 65 °C
10.0 mA @ 20 mA 20 mA) 20 mA) -0.5 Vdc min. in [-40 °F to
16 Vdc max.) off or on 149 °F]
(plus load condition
current)3
4.5 Vdc to 24 Vdc 5 V +0.4 V 10 µA 1.5 µs 0.5 µs -30 Vdc to -0.5 V min. 20 mA -40 °C to
Sinking 7.0 mA (sinking (sinking (sinking +30 Vdc +24 V max. (sinking) 65 °C
(released) 10 mA) 10 mA) 10 mA) (off condition) [-40 °F to
24 V 149 °F]
9.0 mA
(released)
14.0 mA
(operated -
no load)
1 Over temperature range of 0 °C to 55 °C [32 °F to 131 °F] and supply voltage of 4.5 Vdc to 5.5 Vdc.
2 Over temperature range of 0 °C to 55 °C [32 °F to 131 °F] and supply voltage of 16 Vdc.
3 At 24 °C [75 °F]
4 As with all solid state components, performance can be expected to deteriorate as rating limits are approached; however, they will not be damaged
unless the limits are exceeded.
Order Guide
SERIES NAME CAT. LISTING
AML10 Custom
MANUAL SWITCHES AND PUSHBUTTONS
170 www.honeywell.com/sensing
Approvals: UL (E12252), CSA (LR4442)
VDE (0630/10.78*), CE (Rating 1710 No. 4275.5788)
Electromechanical Life
Pushbuttons - Momentary 25,000 (silver); 100,000 (gold)
Pushbuttons - Alternate 25,000
Rockers 25,000
Paddles 25,000
* Exception: Four-pole AMLs are not included in VDE approval.
AML20 Series
AML Series, continued
AML 20 Series Electrical Data
Contacts Voltage Current Load Type
Silver 250 Vac 2 A 75% Power Factor
or 125 Vac 3 A 75% Power Factor
gold-plated silver 24 Vdc 2 A Resistive
Gold 125 Vac/Vdc 100 mA Resistive
Approvals: UL (E12252), CSA (LR4442)
VDE (0630/10.78*), CE (Rating 1710 No. 4275.5788)
Electromechanical Life
Pushbuttons - Momentary 25,000
Pushbuttons - Alternate 25,000
Rockers 25,000
Paddles 25,000
* Exception: Only the two-pole AML33 and AML34 are certified by VDE.
AML30 Series
AML 30 Series Electrical Data
Current Current
Voltage Pushbuttons Rockers or Load Type
Paddles
125 Vac 10 A 15 A 60% Power Factor
250 Vac 10 A 15 A 60% Power Factor
Order Guide
SERIES NAME CAT. LISTING
AML20 Custom
Order Guide
SERIES NAME CAT. LISTING
AML30 Custom
Approvals: UL (E58932), CSA (LR4442)
Electromechanical Life* N/A
AML40 Series
Order Guide
SERIES NAME CAT. LISTING
AML40 Custom
MANUAL SWITCHES AND PUSHBUTTONS
171
www.honeywell.com/sensing
MML Series
Miniature Manual Line
Switches
Features
Breadth of line offers complete selection of pushbuttons, rockers,
and indicators to accommodate different functions and promote
operator efficiency.
Printed wiring board (PWB) or panel-mounted switches, plus multi-
unit strip mounting, and single-level termination for cost-effective
installation.
Tactile feedback imparts a definite feel of switching action.
Coordinated appearance enhances panel harmony.
Illumination by long-life LEDs and incandescent lamps – for lighted
display versatility.
Solid state, electronic control and power-duty switching – for
electrical versatility.
Temperature range 18 °C to 65 °C [0 °F to 149 °F].
Design Freedom
Rocker switches are available in the MML Miniature Manual Line. They
complement AML pushbuttons and indicators, providing you flexibility
and design freedom to meet all your miniature manual control
requirements. You can choose the actuator option that matches the
switch function and natural-habit pattern reflex of the operator. You no
longer need to compromise quality, appearance, or human factors
considerations because of size constraints.
The MML pushbutton and indicator offering has been expanded to
include new square forms which are small enough to fit in the tightest
places.
Mounting Flexibility
Printed wiring board (PWB) mounted switches can be arranged in
individual panel openings or multi-unit strips, in a common panel cutout.
Optional support brackets provide added rigidity for stand-alone PWB-
mounted devices. Units with bezels and mounting clips can be snap-in
mounted from the front panel.
Single-level PWB or solder/quick-connect termination throughout makes
wiring faster, easier, and more economical. Housing are designed to
accommodate washing, before and after wave soldering, to help prevent
contamination during printed wiring board installation.
Lighted Display Options
Pushbuttons and indicators can be full-face illuminated by LEDs or
incandescent lamps for high visibility of colors and legends. Inherently
rugged, long-life LEDs can help reduce service and maintenance costs.
Also, their low drive and in-rush current (30 mA or less) redueces costs
of drive circuitry.
Rockers can be furnished with colored lenses for illumination by LEDs or
incandescent lamps.
Control Versatility
Solid state pushbutton switches with Hall-effect integrated circuits
interface directly with microprocessors and other logic-level devices.
Time-proven for billions of cycles, Hall-effect ICs provide the ultimate in
reliability.
Electronic control push button or rocker switches, with gold or silver
contacts, handle up to 1 A; power-duty switches, up to 6 A.
MML Enhances Panel Harmony
The attractive, clean line design of the total MML offering is coordinated
to work in harmony and enhance the visual qualities of your product.
MML will help make a good first impression with your customers by
blending with other panel components, and also works hard over the
long run to maintain operator satisfaction.
How to Order
To specify MML catalog listings, refer to the order guides. They are
based on a modular cataloging system which gives you the flexibility to
choose the combination of feature options that best answers the
requirements of your application.
MANUAL SWITCHES AND PUSHBUTTONS
172 www.honeywell.com/sensing
MML10 Series
Approvals: UL (E53576), CSA (LR4442)
Mechanical Lifetime*
Pushbuttons – Momentary 1,000,000
Pushbuttons – Alternate 100,000
Rockers 100,000
Electrical Lifetime**
Pushbuttons – Momentary 1,000,000
Pushbuttons – Alternate 100,000
Rockers 100,000
* 95% survival
** Lifetime at full-rated load
MML10 Series Electrical Data
Electrical Characteristics
Integrated circuit function 5 Vdc to 24 Vdc sinking
Supply current (max) 7 mA (released)
8 mA (operated no load)
Output voltage (operated) 0.3 V (sinking 10 mA)
Output leakage current max. 5.0 µA
(released)
Switching time (max).
Rise 10% to 90% 15 µs (sinking 10 mA)
Fall 90% to 10% 0.5 µs (sinking 10 mA)
Rated output current 10 mA sinking
Absolute Maximum Ratings
Supply Voltage (Vs) -28 Vdc to 28 Vdc
Voltage externally applied -0.5 V min.; 28 V max.
to output (off condition)
Loads to output 20 mA (sinking)
Storage temperature -40 °C to 85 °C
[-40 °F to 185 °F]
Operating temperature -18 °C to 65 °C
[0 °F to 149 °F] and supply
voltage of 4.5 Vdc to 5.5 Vdc
As with solid state components, performance can be expected to
deteriorate as rating limits are approached; however, they will not be
damaged unless the limits are exceeded.
Approvals: UL (E12252), CSA (LR4442)
Mechanical Lifetime*
Pushbuttons - Momentary 250,000
Pushbuttons - Alternate 100,000
Rockers 250,000
Electrical Lifetime**
Pushbuttons - Momentary 25,000
Pushbuttons - Alternate 25,000
Rockers 25,000
* 95% survival
** Lifetime at full-rated load
MML20 Series
MML30 Series
Approvals: UL (E12252), CSA (LR4442)
Mechanical Lifetime*
Pushbuttons - Momentary 100,000
Pushbuttons - Alternate 100,000
Rockers 100,000
Electrical Lifetime**
Pushbuttons - Momentary 25,000
Pushbuttons - Alternate 25,000
Rockers 25,000
* 95% survival
** Lifetime at full-rated load
MML30 Series Electrical Data
MML31
Electrical rating 6 A @ 125 Vac, 250 Vac,
2 A @ 30 Vdc
Silver contacts 1 A @ 125 Vdc “L”,
1/10 hp @ 125 Vac
Contact arrangement 1 or 2 poles Form X
Order Guide
SERIES NAME CAT. LISTING
MML30 Custom
MML20 Series Electrical Data
Electrical Rating (silver contacts)
Standard buttons Up to 1 A, 125 Vac
1-piece plunger/ black – up to 1 A, 125 Vac
lens cap buttons All others – up to 0.5 A, 125 Vac
Electrical Rating (gold contacts)
All button styles Up to 0.25 A, 30 Vdc
UL rating - 0.1 A, 30 Vdc
Contact arrangement One pole Form C
Order Guide
SERIES NAME CAT. LISTING
MML20 Custom
MML40 Series
Approvals: UL (E58932), CSA (LR4442)
Order Guide
SERIES NAME CAT. LISTING
MML40 Custom
MANUAL SWITCHES AND PUSHBUTTONS
173
www.honeywell.com/sensing
Switch assemblies
Honeywell has many years of experience designing
custom solutions for customers.
Our environment and hermetically sealed products
may, for instance, be incorporated into housings that
provide minimum space envelope or specific
mounting arrangement.
They may incorporate precision actuating mechanisms and
electronic circuitry to interface with customer systems.
Rotary switches
Based on Honeywell basic or miniature hermetic switches,
rotary switches can be designed to incorporate multiple poles,
specific switch on/off sequences and high or low energy
switching.
Potential applications include weapons selectors, Re-fuelling
probe indicators and flap position indicators.
Customer-specific space envelope and mounting
arrangements can be accommodated.
Harness assemblies
Cable harness assemblies can be added to many of our
products, designed to specific customer requirements.
These may incorporate latest specification leadwire systems,
screens, connectors and backshells and aimed at providing
customers with a fully integrated solutions.
Custom Switches
and Assemblies
Honeywell Sensing and Control’s broad product
and technology portfolio combined with our
industry experience and know-how offers
customers a wealth of choice:
Custom engineered solutions for customer-
specific designs and product packaging
Technology selection
Integration and component miniaturisation
For more information contact your local
Honeywell sales representative.
Shown here are some examples of what we can
do.
CUSTOM SWITCHES AND ASSEMBLIES
Operator interface products
Honeywell has many examples of custom designed
operator interfaced products for both hand and foot
operation.
These products may incorporate pushbuttons,
indicators and electronic interfacing circuitry.
All products are capable of operating in these
most severe environments.
174 www.honeywell.com/sensing
Gear selectors
Based on rotary switches, this family of rugged and reliable gear selectors is used in
armoured vehicle applications.
These products can be modified to meet new
potential applications such as illuminated or
fluorescent gear position indications, number of
gear positions, interlocking, high or low energy
switching and mounting arrangements.
Flap selectors
A range of commercial aircraft flap selectors based on RVDT (Rotary
Variable Differential Transducers) or Honeywell basic switches.
These products can be modified to meet new potential
application requirements such as flap positions, mounting
arrangements, connectors or electrical harnesses.
The example illustrated incorporates four-position flap selection,
environmentally sealed fluorescent flap decal and illuminated position
indicators and is based on RVDTs.
CUSTOM SWITCHES AND ASSEMBLIES
Cargo loading systems
The door sill roller is part of the cargo loading system that serves as a guiding and protecting
element during load and unload operations. Incoming cargo is
guided into the cargo loading bay to protect the cargo door
sill.
The Y-guide is part of the cargo loading system that
controls the lateral guidance of cargo during load and
unload operations at the cargo entrance area. The unit is
designed as a powered, retractable and overrideable guide.
The angle measurement device is part of door actuator
symmetry monitoring. This device prevents damage to the main
cargo door and the structure of the aircraft by monitoring the
asymmetric movement of the two main cargo door actuators.
The example shown is a Y-guide cargo loading system incorporating robust mechanical
components and environmentally sealed position sensors. It is used in commercial aircraft
applications.
175
www.honeywell.com/sensing
Custom Controls
Competition between off-road equipment
manufacturers can be fierce. Honeywell can help
you distinguish yourself from the competition by
working with you in developing your custom
controls and switches. We have innovative and
flexible design capabilities coupled with cost-
effective prices. Quick response including design,
and “fit-up” prototypes in weeks versus months
from your initial request provides the edge you
need to shine over your competition. Control
interfaces that are functional, rugged and
aesthetically pleasing are an important part of the
design process. The ability to ergonomically
design numerous functions into one product is
our strength.
Technological and process
capabilities
Pro/Engineer software
Programmable controllers
Mold flow analysis
Control and switch capability
Sliding, toggle and button engagement
Environmentally protected
Night visibility/lighted components
Directional
Speed control
Molded terminal arrays
Ergonomically sensitive
Indicator light panels
Potential Applications
All terrain vehicles (ATVs)
Forestry
Agriculture
Lawn and garden
Snowmobiles
Motorcycles
Construction
Material handling
Multi-function controls
Electronic shifters
Throttle controls
Indicator light strips
Push/Pull switches
Key switches
CUSTOM CONTROLS
Proportional retarders
VEHICLE CONTROLS
176 www.honeywell.com/sensing
HOUR METERS
Hour meters
Honeywell has a wide range of hour meters that are used for recording and tracking
the total elapsed time that equipment is in use.
Long recognised as the industry leader, the Hobbs brand hour meters are designed
for use in a wide variety of potential applications and environments. In order to
protect investment in expensive equipment, our customers demand a meter that is
accurate and dependable. Down time is not an option - customers need to know
when it is time to service their equipment.
No matter whether the equipment is for production or recreation, manufacturers,
operators and service professionals rely on Honeywell for their hour meters needs.
177
www.honeywell.com/sensing
98000 Series
LCD hour meters
The 98000 Series LCD hour meter combines reliability with a solid state
package, built for rugged, heavy-duty applications. The meter utilizes a
large LCD display with 6 mm [0.24 in] high digits.
Other benefits include shorter overall meter depth, totally silent
operation, non-volatile memory and solid-state circuitry. A wide variety
of mounting styles are offered that are direct replacements for most
traditional hour meters. Optional offerings include, reset capability,
customised logos, 4.5 Vdc to 16 Vdc, and pulse counters. The series is
UL recognised and comes in a variety of mounting and case options.
Termination: 6,35 mm [¼ in] blade
Sealing: IP66 (Cased hour meters only)
Approvals: UL
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Voltage range: 9 Vdc to 64 Vdc
OPTIONS
2 Screw, deluxe bezel
34,30
(1.35)
22,60
(0.89)
2,00
(0.08) 54,10 (2.13)
35,80 (1.41)
19,10
(0.75)
31,80
(1.25)
3,60
(0.14)
2 Screw Deluxe:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
2 x 3,81 (0.15) holes spaced 44,45 (1.750)
NUMBER OF TERMINALS CAT. LISTING
2 98313
3 98323
4 with reset 98303
Rectangular, retainer mount
2,50
(0.10)
27,40
(1.08)
40,60 (1.60)
34,30
(1.35)
19,10
(0.75)
Retainer Mount:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
NUMBER OF TERMINALS CAT. LISTING
2 98311
3 98321
4 98301
Round, 2¼ in [57,15 mm], chrome, flush cup
mount
Ø
57,7
(2.27)
Ø
50,8
(2.00)
3,00
(0.12)
18,5
(0.73)
15,2
(0.60)
7,60
(0.30)
Ø 61,2 (2.41)
Ø 50,4 (1.985)
Flush Mount (Retainer) 57,77 (2.27):
Panel cutout 50,8 (2.00) Ø opening
NUMBER OF TERMINALS CAT. LISTING
2 98314
3 98324
4 98304
Round, 2¼ in [57,15 mm], black, flush cup mount
Ø
57,7
(2.27)
Ø
50,8
(2.00)
3,00
(0.12)
18,5
(0.73)
15,2
(0.60)
7,60
(0.30)
Ø 61,2 (2.41)
Ø 50,4 (1.985)
Flush Mount (Retainer) 57,77 (2.27):
Panel cutout 50,8 (2.00) Ø opening
NUMBER OF TERMINALS CAT. LISTING
2 98312
3 98322
4 98302
HOUR METERS
178 www.honeywell.com/sensing
HOUR METERS
98000 Series
LCD hour meter modules
The LCD hour meter module is a custom engineered elapsed time meter
designed to be mounted directly onto a printed circuit board (PCB). It
can be used in a variety of dc applications that require an hour meter for
preventative maintenance, warranty verification, renting and leasing. LCD
counter also available.
Approvals: UL, CSA
Voltage range: A 9 Vdc to 64 Vdc
B 4.5 Vdc to 16 Vdc
14,00
(0.55)
5,90
(0.23)
33,78 (1.33)
27,94 (1.10)
0,135
(3.43)
20,57
(0.81)
Ø 0,76 ±0,05
(0.03 ±0.002)
5,84 (0.23)
Mounting surface
5,08 (0.20)
7,62
(0.30)
26,03 (1.025)
15,24 (0.60)
NUMBER OF TERMINALS VOLTAGE RANGE CAT. LISTING
4 A 98706
4 B 98707
Metal bezel 4 A 98750
CAUTION
All meter modules have crucial components exposed. The module must be
sufficiently protected if used in an environment other than specified.
Contact Honeywell when suitability of application is questioned.
98000 Series
LCD volt/hour meters
Honeywell Sensing and Control has introduced the LCD volt/hour meter that
combines two important instruments in one rugged, sealed package.
Honeywell volt hour meters monitor the condition of battery electrical
systems and simultaneously measure the total elapsed run time of
equipment in which they are installed. During operation, the micro-controller
based movement will cycle the LCD display between voltage and hours
indication at a rate of fifteen seconds on for voltage and one second on for
total hours. The high-impact polycarbonate case is sealed against dust and
moisture. Available in various bezel and mounting configurations,
Honeywell’s volt/hour meters are the perfect choice for a variety of
applications.
Termination: 6,35 mm [¼ in] blade
Sealing: IP66
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Voltage range: 7 Vdc to 19 Vdc
OPTIONS
Combination volt/hour meters
2 Screw, deluxe bezel
34,30
(1.35)
22,60
(0.89)
2,00
(0.08) 54,10 (2.13)
35,80 (1.41)
19,10
(0.75)
31,80
(1.25)
3,60
(0.14)
2 Screw Deluxe:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
2 x 3,81 (0.15) holes spaced 44,45 (1.750)
CAT. LISTING
98103
Rectangular, retainer mount
2,50
(0.10)
27,40
(1.08)
40,60 (1.60)
34,30
(1.35)
19,10
(0.75)
Retainer Mount:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
CAT. LISTING
98101
179
www.honeywell.com/sensing
98000 Series
LCD volt/hour meters (continued)
Combination volt/hour meters
Round, 2¼ in [57,15 mm], chrome, flush cup
mount
Ø
57,7
(2.27)
Ø
50,8
(2.00)
3,00
(0.12)
18,5
(0.73)
15,2
(0.60)
7,60
(0.30)
Ø 61,2 (2.41)
Ø 50,4 (1.985)
Flush Mount (Retainer) 57,77 (2.27):
Panel cutout 50,8 (2.00) Ø opening
CAT. LISTING
98111
Round, 2¼ in [57,15 mm], black, flush cup mount
Ø
57,7
(2.27)
Ø
50,8
(2.00)
3,00
(0.12)
18,5
(0.73)
15,2
(0.60)
7,60
(0.30)
Ø 61,2 (2.41)
Ø 50,4 (1.985)
Flush Mount (Retainer) 57,77 (2.27):
Panel cutout 50,8 (2.00) Ø opening
CAT. LISTING
98102
Maintenance Meter
CAT. LISTING
98202
Volt meters
The volt meter incorporates the features and benefits of the LCD volt
hour meter but is used for volts only. The large easy to read LCD display
provides a digital readout of the vehicle voltage. Available in standard
Round, 2-Screw and Rectangular case configurations, volt meters
require only battery positive and ground leads for installation and
operation.
Termination: 6,35 mm [¼ in] blade
Sealing: IP66
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Voltage range: 7 Vdc to 19 Vdc
2 Screw, deluxe bezel
CAT. LISTING
98108
Rectangular, retainer mount
CAT. LISTING
98106
Round, 2¼ in [57,15 mm], chrome, flush cup
mount
CAT. LISTING
98110
Round, 2¼ in [57,15 mm], black, flush cup mount
CAT. LISTING
98109
HOUR METERS
180 www.honeywell.com/sensing
HOUR METERS
85000 Series
Quartz plus dc hour meters
The Quartz Plus Series of hour meters are aimed at providing
performance and reliability. Features include a highly reliable drive
mechanism and odometer gear train combined with the accuracy of
quartz crystal timing. The totally sealed meters are UL/CSA recognized
and come in a variety of mounting styles.
Termination: 6,35 mm [¼ in] blade
Sealing: IP67
Approvals: UL, CSA
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Voltage range: A 10 Vdc to 80 Vdc
B 6.5 Vdc to 16 Vdc
C 10 Vdc to 32 Vdc
OPTIONS
2 Screw, bezel
54,10 (2.13)
32,00
(1.26)
23,88
(0.94)
6,10
(0.24)
36,58 (1.44)
2,03
(0.08)
47,50
(1.87)
8,38
(0.33)
2 Screw Mount:
Panel cutout 36,83 x 24,13 (1.45 x 0.95)
rectangular opening
2 x 3,81 (0.15) holes spaced 44,45 (1.750)
VOLTAGE RANGE CAT. LISTING
A 85094
B 85331
3 Screw, round
47,50
(1.87)
8,38
(0.33)
3 Screw Mount:
Panel cutout 50,80 (2.00) Ø opening
3 x 3,81 (0.15) holes equally spaced on a
64,26 (2.53) bolt circle Ø
Ø
72,64
(2.86)
Ø
55,63
(2.19)
7,11
(0.28)
3,30
(0.13)
Ø 50,42 (1.985)
VOLTAGE RANGE CAT. LISTING
A 85097
Rectangular, stirrup mount
6,10
(0.24)
31,75
(1.25)
44,70 (1.76)
2,03
(0.08)
47,50
(1.87)
8,38
(0.33)
Rectangular Stirrup:
Panel cutout 36,83 x 24,13 (1.45 x 0.95)
rectangular opening
73,15
(2.88)
VOLTAGE RANGE CAT. LISTING
C 85010
Rectangular, retainer mount
48,01
(1.89)
55,63
(2.19)
2,54
(0.10)
26,16
(1.03)
39,37 (1.55)
Rectangular Retainer:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
Sealing: IP66
VOLTAGE RANGE CAT. LISTING
A 82320
181
www.honeywell.com/sensing
85000 Series
Quartz plus dc hour meters (continued)
Round, 2¼ in [57,15 mm], chrome, flush cup
mount
Ø
57,66
(2.27)
Ø
50,80
(2.00)
Ø 50,42 (1.985)
8,38
(0.33)
47,75
(1.88)
3,05
(0.12)
7,62
(0.30)
Ø 61,21 (2.41)
Flush Mount (Cup):
Panel cutout 57,66 (2,27)
50,80 (2.00) Ø opening
VOLTAGE RANGE CAT. LISTING
A 85342
Round, 2¼ in [57,15 mm], black, flush cup mount
Ø
57,66
(2.27)
Ø
50,80
(2.00)
Ø 50,42 (1.985)
8,38
(0.33)
47,75
(1.88)
3,05
(0.12)
7,62
(0.30)
Ø 61,21 (2.41)
Flush Mount (Cup):
Panel cutout 57,66 (2,27)
50,80 (2.00) Ø opening
VOLTAGE RANGE CAT. LISTING
A 85093
82400 Series
Quartz dc hour meters, polarity insensitive
Termination: 6,35 mm [¼ in] blade
Sealing: IP66
Approvals: UL
Operating temperature: -40 °C to 85 °C [-40 °F to 185 °F]
Voltage range: 10 Vdc to 80 Vdc
OPTIONS
2 Screw, bezel
22,6
(0.89)
2,00
(0.08) 54,10 (2.13)
35,8 (1.41)
31,80
(1.25)
3,60
(0.14)
55,60
(2.19)
48,00
(1.89)
CAT. LISTING
82416
Rectangular, retainer mount
48,01
(1.89)
55,63
(2.19)
2,54
(0.10)
26,16
(1.03)
39,37 (1.55)
Rectangular Retainer:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
CAT. LISTING
82401
HOUR METERS
182 www.honeywell.com/sensing
HOUR METERS
20000 Series
Deluxe ac hour meters
Honeywell’s 20000 Series Deluxe ac meter is a completely sealed hour meter
that utilizes a synchronous motor to drive the odometer gear train. Meters
are available in a combination of mounting styles, voltages and frequencies
and are UL Listed, CSA and CE Certified.
Termination: Screw
Sealing: IP65
Approvals: UL, CSA, CE
Operating temperature: -54 °C to 68 °C [-65 °F to 154 °F]
Voltage range: A 120 Vac, 60 Hz
B 240 Vac, 60 Hz
C 120 Vac, 50 Hz
D 240 Vac, 50 Hz
OPTIONS
2 Screw, bezel
64,80
(2.55)
50,80
(2.00)
4,20
(0.165)
52,60 (2.07)
36,6 (1.44)
2,70
(0.11)
25,90
(1.02)
22,70
(0.89)
35,5 (1.40)
2 Screw Mount:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
2 x 3,81 (0.15) holes spaced 44,45 (1.750)
VOLTAGE RANGE CAT. LISTING
A 20001
B 20007
C 20028
D 20029
3 Screw, round
60,50
(2.38)
46,50
(1.83)
7,40
(0.29)
Ø 50,40 (1.985)
Ø 55,60
(2.19)
Ø 68,60
(2.70)
3,30
(0.13)
3 Screw Mount:
Panel cutout 50,8 (2.00) Ø opening
3 x 3,175 (0.125) holes equally spaced on
61,47 (2.42.) circle Ø
VOLTAGE RANGE CAT. LISTING
A 20017
B 20019
C 20016
D 20018
Round, 2¼ in [57,15 mm], black, retainer mount
Ø
50,42 (1.985)
7,62
(0.30)
47,50
(1.87)
5,33
(0.21) 2,79
(0.11)
Ø
49,78
(1.96)
Ø
56,90
(2.24)
CAT. LISTING
82404
82400 Series
Quartz dc hour meters, polarity insensitive
(continued)
183
www.honeywell.com/sensing
28000 Series
Standard ac hour meters
The Honeywell 28000 Series ac hour meters use a synchronous motor
to drive the odometer gear train. These meters can be used in a wide
variety of potential applications including control panels and medical
applications. All styles are UL, CSA and CE certified.
Termination: 6,35 mm [¼ in] blade
Sealing: IP64
Approvals: UL, CSA, CE
Operating temperature: -54 °C to 68 °C [-65 °F to 154 °F]
Voltage range: A 120 Vac, 60 Hz
B 240 Vac, 60 Hz
C 120 Vac, 50 Hz
D 240 Vac, 50 Hz
OPTIONS
Rectangular, retainer mount
48,01
(1.89)
55,63
(2.19)
2,54
(0.10)
26,16
(1.03)
39,37 (1.55)
Rectangular Retainer:
Panel cutout 36,83 x 24,13 (1.45 x 0.95) rectangular opening
VOLTAGE RANGE CAT. LISTING
A 28000
B 28004
C 28002
D 28006
Round, 2¼ in [57,15 mm], retainer mount
VOLTAGE RANGE CAT. LISTING
A 28030
HOUR METERS
184 www.honeywell.com/sensing
Key Switches
KEY SWITCHES
OPTIONS
Screw terminals
72,39
2.85
39,88
1.57
Ø
41,15
1.62
SWITCH POSITIONS CAT. LISTING
2 (Off/On) 84828
3 (Off/On/Start) 84829
3 (On/Off/On) 84830
Honeywell Key switches are custom engineered, environmentally sealed,
sliding contact switches. They can be designed to match existing keys or to
use a six tumbler mechanism with up to 300 unique key combinations. The
stainless steel keyhole shroud and keyhole dust shutter contribute to the
durability of the assembly while O-rings protect the contact and rotor
assembly from moisture and contamination.
Key switches can be used in off-highway, material handling or other
potential applications where environmental specifications must be met.
They have been tested for temperature, vibration, dust, cycling,
humidity, pressure wash and salt fog and mount into a 22,10 mm [0.87
in] hole in panels 3,81 mm to 6,35 mm [0.15 in to 0.25 in] thick.
Standard configurations are shown below, others are available. Contact
your Honeywell sales representative for more information.
Mechanical life: 25000 cycles
Operating temperature: -40 °C to 85 °C
[-40 °F to 185 °F]
Connector: Screw or Packard MetriPack 280 Series
Electrical rating: Screw - 20 A, 12 Vdc
10 A, 24 Vdc
4 A, 48 Vdc
Packard MetriPack - 20 A, 12 Vac
8 A, 24 Vac
OFF
ON
45˚
OFF - ON
OFF START
ON 45˚
45˚
OFF - ON - START
(Key removable in OFF position)
OFF
ON ON
45˚
45˚
ON - OFF - ON
(Key removable in OFF position)
2 Position 3 Position 3 Position
OFF
ON
START
PREHEAT
22.5˚
22.5˚
45˚
OFF - ON - PREHEAT - START
(Key removable in OFF position)
4 Position
Integral connector
Ø
41,15
1.62
74,93
2.95
43,43
1.71
SWITCH POSITIONS CAT. LISTING
2 (Off/On) 84825
3 (Off/On/Start) 84826
3 (Off/On/Start, Magneto Ground) 89165
4 (Off/On/Preheat/Start) 89477
185
www.honeywell.com/sensing
PUSH/PULL SWITCHES
Push/Pull Switches
Honeywell’s Push/Pull switches are robust, environmentally sealed,
positive action, sliding contact switches incorporating two circuits with
multiple combinations. The switch can be designed with a single contact
closure in either the push or pull position, two contact closures in either
the push or pull positions or a single contact closure in both the push
and pull position. For more details on these options, contact a Honeywell
sales office. The dual O-ring design protects the contact chamber by
isolating it from moisture or any other contaminant.
These switches may be suitable for the demands of harsh environments
found in off-highway, material handling or other applications where
rapid, positive action is required.
Mechanical life: 25000 cycles
Operating temperature: -40 °C to 100 °C
[-40 °F to 212 °F]
Connector: Screw Terminals
Electrical rating: 20 A, 12 to 14 Vdc
10 A, 24 Vdc
Sealing: IP67
72,01
(2.835) 28,32
(1.115)
Mounting panel
thickness
1,27 - 4,83
(0.05 - 0.19)
CIRCUITRY CAT. LISTING
2NO Circuits in Push 87941
1NO/1NC Circuits in Push 87943
186 www.honeywell.com/sensing
Shifters
SHIFTERS
Honeywell electromechanical shifters are often ideal for meeting the
direction and speed control requirements of most off-highway
applications. They are completely sealed and are built to withstand the
harsh environments of the off-highway industry.
Mounting clamps for shifters and turn signals are available to order
separately, with or without locating pin, for column sizes shown in order
guides.
Standard configurations are shown below, others are available. Contact your
Honeywell sales representative for more information.
Shifter - FNR
Forward, Neutral, Reverse
OPTIONS
Column size 38 mm or 45 mm [1.50 in or 1.77 in]
Integral Packard connector
FEATURES MOUNTING CAT. LISTING
Neutral lock left or right 80438
No neutral lock left or right 81521
Neutral lock/Wash/wipe right 86835
Wire harness connector
FEATURES MOUNTING CAT. LISTING
Neutral lock left 80909
Column size 55 mm [2.17 in]
Integral Deutsch connector
FEATURES MOUNTING CAT. LISTING
Neutral lock/Horn left 80910
Shifter - FNR
Forward, Neutral, Reverse with speed selector
OPTIONS
Column size 38 mm or 45 mm [1.50 in or 1.77 in]
Integral Deutsch connector
FEATURES MOUNTING SPEEDS CAT. LISTING
Neutral lock left 4 81248
Neutral lock/button left 3 81426
No neutral lock left 3 81758
Neutral lock left bump 84105
Neutral lock right 6 85874
Wire harness connector
FEATURES MOUNTING SPEEDS CAT. LISTING
Neutral lock left 4 84467
Mechanical life:
Rotary 1 million cycles (2 A, 12 V load)
Shifter handle 500,000 cycles
Lever with drop down neutral lock 3 million cycles
without drop down neutral lock 5 million cyles
Sealing: IP67
Operating temperature: -40 °C to 85 °C
[-40 °F to 185 °F]
Supply voltage: 3V to 32 V operation [12 V or 24 V typ.]
Mounts to column size: 38 mm, 45 mm or 55 mm
[1.50 in, 1.77 in or 2.17 in]
Neutral lock: Drop down
Connector: Integral Packard, Integral Deutsch or Wire harness
12.5˚
12.5˚
N
F
78,79
(3.102)
75,46
(2.971)
6,10
(0.24)
65,02
(2.56)
Ø
38,18
(1.503)
Ø
44,45
(1.750)
Button switch handleTwist grip handle with button switch
59,18
(2.33)
27,94
(1.10)
220,47
(8.68) 198,50
(7.50)
Optional mounting clamps
COLUMN SIZE CAT. LISTING
38 mm [1.50 in] 80260
45 mm [1.77 in] 80262
187
www.honeywell.com/sensing
PROPORTIONAL RETARDERS
Proportional Retarders
Honeywell’s Proportional Retarder is a shift-lever handle that attaches to
the steering column of a vehicle and gives an electronic pulse-width-
modulated output signal that is proportional to the position of the lever.
In standard mounting position, output signal has 10 % duty cycle when
lever is pulled towards operator to maximum extent. When moved away
from operator to its maximum travel, the lever snaps into a detent
indicating the output signal now has 90 % duty cycle. The duty cycle
between these two positions is a continuously variable function of
position.
Housed in a sealed unit with a rugged, positive locking connector, the
proportional retarder has reverse voltage, short circuit and over voltage
protection.
Travel: 25° maximum angle travel
Supply Voltage: 9 Vdc to 32 Vdc
(12 Vdc to 24 Vdc operating system)
Base Frequency: 500 Hz, ± 10 % over temperature and input voltage
Duty Cycle: 10 % to 90 %, ± 5 % at limits of travel
Output Voltage: Pulse-width-modulated, 0 V to 7 V amplitude
Wiring and Connection: Receptacle compatible with
positive-locking Deutsch DT06-6S connector
with 18 AWG (minimum wiring to conform to 1E815)
188 www.honeywell.com/sensing
Turn Signals
Honeywell Turn signal switches are built to complement the Honeywell
shifters or can be mounted independently. A variety of potential
operations are available such as wiper speeds, head lamp control, button
and auto cancel options.
These switches can be tailored to meet your design requirements;
contact Honeywell for more information.
Mechanical life: Turn signal 50,000 cycles (8 A, 12 V load)
Wiper 50,000 cycles (2 A, 12 V load)
Washer 20,000 cycles (2 A, 12 V load)
Head lamp dimmer 20,000 cycles (15 A, 12 V load)
Sealing: IP67
Operating temperature: -40 °C to 85 °C
[-40 °F to 185 °F]
Supply voltage: 3V to 32 V operation (12 V or 24 V typ.)
Mounts to column size: 38 mm, 45 mm, 55 mm
[1.50 in, 1.77 in, 2.17 in]
Connector: Integral Packard, Integral Deutsch or Wire harness
78,99
(3.11) 82,80
(3.26)
65,02
(2.56)
Ø
38,18
(1.503)
Ø
55,12
(2.17)
Button switch handle
Plain handle
61,98
(2.44)
Ø
36,07
(1.42)
1 2 3 4 5 6
12 11 10 9 8 7
50,8
(2.00)
232,16
(9.14) 230,63
(9.08)
84,07
(3.31)
12.5˚
12.5˚
Turn signal
Integral Deutsch connector
FEATURES COLUMN SIZE CAT. LISTING
MM [IN]
55 [2.17] 80877
Turn signal with wiper control
Integral Deutsch connector
FEATURES COLUMN SIZE WIPER CAT. LISTING
MM [IN] SPEEDS
Wash 38/45 [1.50/1.77] Hi/Lo 80350
Wash 55 [2.17] 1 80876
Turn signal with head lamp control
OPTIONS
Integral Packard connector
FEATURES COLUMN SIZE LIGHTS CAT. LISTING
MM [IN]
45 [1.77] Hazard warning 84884
Integral Deutsch connector
FEATURES COLUMN SIZE LIGHTS CAT. LISTING
MM [IN]
Horn/side marker 45 [1.77] Head lamp switch/Dimmer 81705
Wire harness connector
FEATURES COLUMN SIZE LIGHTS CAT. LISTING
MM [IN]
45 [1.77] Head lamp switch 79809
Turn signal with wiper and head lamp
control
OPTIONS
Integral Deutsch connector
FEATURES COLUMN SIZE WIPER SPEEDS LIGHTS CAT. LISTING
MM [IN]
Wash 45 [1.77] 1 Head lamp 81601
dimmer/Flash
Wire harness connector
FEATURES COLUMN SIZE WIPER SPEEDS LIGHTS CAT. LISTING
MM [IN]
Wash 45 [1.77] 1 Dimmer/Flash 80279
Wash 45 [1.77] Hi/Lo/Intermittent Dimmer 82570
Wash/Horn/Auto cancel 38/45 [1.50/1.77] Hi/Lo/Intermittent Dimmer/Flash 86320
Wash/Horn 45 [1.77] Hi/Lo Dimmer/Flash 86508
TURN SIGNALS
Optional mounting clamps
COLUMN SIZE CAT. LISTING
38 mm [1.50 in] 80260
45 mm [1.77 in] 80262
189
www.honeywell.com/sensing
Lighting products
Honeywell continues the Hobbs tradition of rugged, off-highway work
lamps. More than 20 million incandescent and halogen work lamps
have been put to use in some of the most rugged working environments
imaginable. Because they are designed for potential use in heavy
construction and farming equipment, they are also designed to take
shock, vibration and other extreme service conditions in their stride.
Sealing: IP67
Electrical rating (Voltage/Wattage/Current]:A 12 Vdc/50 W/4 A
B 24 Vdc/60 W/2.5 A
LIGHTING
Halogen Swivel Mount Lamps
Honeywell offers a full line of heavy-duty, halogen, off highway, vehicle
lamps to keep equipment moving long after the sun has set. Our halogen
lamp housings are constructed of durable, vibration resistant materials. The
securing hardware is zinc plated steel with a black dichromate coating.
Reflectors are vacuum metalised. The borosiliate glass lenses are highly
resistant to cracking, especially when subjected to extreme temperature
changes.
Mounting: Stud, ½ in [12,7 mm) Ø
OPTIONS
3 in x 5 in [76,2 mm x 127,0 mm]
3.77 REF
1/2-13 NC-2
STUD
5.89
(149,60)
REF
3.53
(89,66)
REF
3.09
(78,49)
REF
3.15
(80,01)
REF
3.77
(95,76)
REF
Dimensions in inches (millimetres)
BEAM PATTERN ELECTRICAL RATING CAT. LISTING
Wide Flood A 73761
Trapezoid A 73763
Spot A 73764
4 in x 6 in [101,6 mm x 152,4 mm]
1.2-13 NC-2
Stud
4.49
(114,0)
REF
3.10
(78,7)
REF
6.90
(175,3)
REF
3.12
(78,25)
REF
3.16
(80,26)
REF
2.24
(56,89)
REF
Dimensions in inches (millimetres)
BEAM PATTERN ELECTRICAL RATING CAT. LISTING
Wide Flood A 71898
Wide Flood B 72540
Trapezoid A 71915
Trapezoid B 72542
Spot A 71902
Spot B 72544
100'
1000'
50'
Flood
50 Ft. x 30 Ft. Trap
25 Ft. x 100 Ft. Spot
1000 Ft.
Standard Beam Patterns
190 www.honeywell.com/sensing
LIGHTING
Replacement Sealed Beams
Replacement sealed beams are offered in both 3 in x 5 in [76,2 mm x
127,0 mm] and 4 in x 6 in [101,6 mm x 152,4 mm] rectangular size
lenses. These are designed with the same rugged construction as the
originals and are designed to meet the same demanding standards.
These lamps are also designed to withstand tough environmental
conditions, such as sudden temperature change, shock and intense
vibration.
OPTIONS
3 in x 5 in [76,2 mm x 127,0 mm]
5.89
(149,61)
REF
3.53
(89,66)
REF
Dimensions in inches (millimetres)
BEAM PATTERN ELECTRICAL RATING CAT. LISTING
Wide Flood A 72408
Trapezoid A 72801
Spot A 73804
4 in x 6 in [101,6 mm x 152,4 mm]
6.90
(175,26)
REF
4.49
(114.05)
REF
Dimensions in inches (millimetres)
BEAM PATTERN ELECTRICAL RATING CAT. LISTING
Wide Flood A 71017
Wide Flood B 72541
Trapezoid A 71792
Trapezoid B 72543
Spot A 71794
Spot B 72545
Round Halogen Lamps, PAR 36
The PAR 36 Halogen work lamp may be well suited to more traditional
agricultural equipment applications. They are virtually the same 4.5 in
[114,3 mm] diameter lamps that have been factory-installed on popular
makes of combines and tractors over the years.
4.5 in [114,3 mm] Ø lamp
Dimensions in inches [millimetres]
5.25
(133,35)
4.5
(114,30)
5.25
(133,35)
BEAM PATTERN ELECTRICAL RATING CAT. LISTING
Wide flood A 73468
Trapezoid A 73469
191
www.honeywell.com/sensing
SEALED SWITCHES
LIGHTING
Portable Work Lamp
The Portable work lamp is often ideal for situations when temporary
lighting is required. It can be used to replace failed equipment lighting,
light dark areas, or service equipment. It is also useful for recreational
activities.
It operates by plugging the connector into a 12 Vdc cigarette lighter. The
work lamp is supplied with a 15 foot [4,92 metre] electrical cable and an
80 lb [36,4 kg] magnet in the base.
3 in x 5 in [76,2 mm x 127,0 mm]
with handle and switch
Dimensions in inches [millimetres]
6.00
(152,40)
4.75
(120,65)
3.50
(88,90)
BEAM PATTERN ELECTRICAL RATING CAT. LISTING
Wide flood A 80413
Spot A 80510
HID Xenon
High Intensity Discharge Lamps
Honeywell Xenon high intensity discharge lamps are designed to hold up
to the extreme demands of the off-highway construction and agricultural
markets. HID technology is significantly more efficient than halogen and
produces more light with less amperage draw.
HID lamps can provide up to three times the light output compared to
the average halogen lamp. The technology allows equipment to operate
more safely with less load on the electrical system resulting in optimum
alternator and battery life.
Honeywell’s HID features an electronic bulb/igniter/ballast system for
enhanced performance throughout a broad temperature and vibration
range. This reduces normal failure modes including filament breakage
producing a life expectancy up to six times greater than a typical halogen
lamp.
Electrical rating: 12 V [42 W] 24 V [42 W]
Operating voltage range: 9 V to 16 V 10 V to 32 V
Startup amperage: 15 A @ 9 V, 8 A @ 14 V,
9 A @ 16 V 5 A @ 32 V
Stabilised amperage: 15 A @ 9 V, 3.3 A @ 14 V,
2.7 A @ 16 V 1.4 A @ 32 V
Startup time: 0.1 to 5 seconds 0.1 to 5 seconds
138,94
(5.47)
138,94
(5.47) 189,23
(7.45)
57,15
(2.25)
22,35
(0.88)
146,05
(5.75) 152,50 ± 19,05
(6.00 ± 0.75)
to back of housing
5,08 (0.20)
strip
76,96
(3.03) 1/2-13 NC-2
Stud
#16 GA. b lack wire (-)
#16 GA. red wire (+)
12 Volt (System requirement of 42 Watts]
35 W D1S source
CAT. LISTING
Wide flood 84760-50
Spot 88217-50
24 Volt (System requirement of 42 Watts]
35 W D1S source
CAT. LISTING
Wide flood 88735-50
Trapezoid 88913-50
192 www.honeywell.com/sensing
LIGHTING
Marine Lamps
Replacement Sealed Beam
Honeywell’s marine lamps are completely weatherproof. They are totally
sealed against moisture ingress, and the mounting hardware is stainless
steel to prevent rust and corrosion. The housing is shock resistant and can
withstand up to 6 G vibration. The flood pattern illuminates an area 80° wide
by 30° long.
Suitable applications for Honeywell marine lamps include:
Engine compartment lighting Shrimp and fishing boats
Deck lighting Off-shore oil rigs
Emergency lighting Ocean vessels
Launching and docking Barges
Spreader lights Dry dock lighting
Freighters, tankers, etc.
Pleasure craft
Anywhere a corrosion resistant
lamp is needed
OPTIONS
3 in x 5 in [76,2 mm x 127,0 mm]
3.77 REF
1/2-13 NC-2
STUD
5.89
(149,60)
REF
3.53
(89,66)
REF
3.09
(78,49)
REF
3.15
(80,01)
REF
3.77
(95,76)
REF
Dimensions in inches (millimetres)
5.89
(149,61)
REF
3.53
(89,66)
REF
Dimensions in inches (millimetres)
BEAM PATTERN MOUNTING ELECTRICAL LAMP REPLACEMENT SEALED
RATING CAT. LISTING BEAM CAT. LISTING
Wide Flood Stud A 73620 74041
4 in x 6 in [101,6 mm x 152,4 mm]
1.2-13 NC-2
Stud
4.49
(114,0)
REF
3.10
(78,7)
REF
6.90
(175,3)
REF
3.12
(78,25)
REF
3.16
(80,26)
REF
2.24
(56,89)
REF
Dimensions in inches (millimetres)
6.90
(175,26)
REF
4.49
(114.05)
REF
Dimensions in inches (millimetres)
BEAM PATTERN MOUNTING ELECTRICAL LAMP REPLACEMENT SEALED
RATING CAT. LISTING BEAM CAT. LISTING
Wide flood Flush A 72656 72108
Wide flood Stud A 71723 72108
Wide flood Flush B 72666 72728
Wide flood Stud B 72530 72728
Spot Flush A 72715 72719
Spot Stud A 72716 72719
Spot Flush B 72717 72720
Spot Stud B 72718 72720
Stud mount lamp
Replacement Sealed Beam
Stud mount lamp
3 in x 5 in lamp with
spreader bracket
Flush mount lamp
193
www.honeywell.com/sensing
LIGHTING
Marine HID Lamps
Honeywell’s HID marine lamps are completely weatherproof. They are
totally sealed against moisture ingress, and the mounting hardware is
stainless steel to prevent rust and corrosion.
138,94
(5.47)
138,94
(5.47) 189,23
(7.45)
57,15
(2.25)
22,35
(0.88)
146,05
(5.75) 152,50 ± 19,05
(6.00 ± 0.75)
to back of housing
5,08 (0.20)
strip
76,96
(3.03) 1/2-13 NC-2
Stud
#16 GA. b lack wire (-)
#16 GA. red wire (+)
12 Volt (System requirement of 42 Watts]
35 W D1S source
BEAM PATTERN CAT. LISTING
Wide flood 88432
Trapezoid 89444
Spot 89445
24 Volt (System requirement of 42 Watts]
35 W D1S source
BEAM PATTERN CAT. LISTING
Wide flood 89446
Trapezoid 89447
Spot 89448
Custom Vehicle Lighting
Lighting products designed to the form, fit and functional requirements
of OEM vehicles is the fastest growing segment in lighting. Continual
investment in the latest equipment and software allows optical designs to be
created in unique shapes and sizes to meet this need.
Honeywell Product Management and Engineering personnel can offer a
complete custom design based upon the goals provided. Our manufacturing
facilities are equipped to produce such lights in a matter of weeks. This
quick turn around for prototype and production components is aimed at
meeting even the most aggressive project timetables.
194 www.honeywell.com/sensing
Pressure switches
Extensive portfolio of existing designs
Designed for transportation-related applications
(12 Vdc)
Custom designs possible
Potential applications include engine oil pressure,
compressor air pressure, heavy truck air brake
pressure, transmission fluid pressure
Modular designs
Circuit breakers
Extensive portfolio of existing designs
Designed for 12 Vdc applications
Type 1 automatic reset
Type 2 remote reset
Type 3 manual reset
Multiple designs, terminal styles, and mounting
brackets
5 A to 50 A
Mechanical switches
Extensive portfolio of existing designs
Designed for 12 Vdc applications
Multiple designs and terminal styles
Potential applications include neutral start,
reverse lamp, and 4WD transfer case mode
indication
Other Vehicle
Controls
Honeywell Sensing and Control’s broad product
and technology portfolio combined with
industry experience and application know-how
offers customers a wealth of choice:
Custom engineered solutions for application-
specific designs and product packaging
Proven technology
Low cost
Automotive grade
Extensive portfolio of designs
Extensive high-volume experience
OTHER VEHICLE CONTROLS
195
www.honeywell.com/sensing
Flight control actuation
Linear and rotary flight control actuators with
integral position feedback, clutches, brakes,
dual motors and other options.
These linear actuators are typically used for
helicopter blade control. Many small aircraft
use our rotary actuators in their autopilot
systems.
Flight control position sensing
Our linear and rotary position transmitters solve
challenging measurement problems in harsh
environments.
Added value through features such as integral
gear-train and discreet switches, non-linear
response, viewing window, auto-rig-lock feature.
Cockpit controls
Force and torque sensors integrated into flight control
linkage measure pilot input forces.
Speedbrake, flap selector, and other pilot input devices
incorporating built-in detents, servo backdrive, and up
to quad-channel redundant output.
Cockpit indicators
Analog cockpit indicators serve potential applications
such as angle of attack, fuel quantity, fuel flow.
Dial, pointer and range markings can be designed to
meet almost any customer requirement.
Instruments can be either wedge lighted, backlit,
unlighted, or night vision compliant.
Pressure switches and transmitters
Pressure switches for a variety of potential
applications including engine, hydraulics, and bleed-
air. Available in a wide operating range with preset
dead-band.
Our extremely rugged electromechanical pressure
transmitters operate at 250 °C [482 °F] and pressures
as high as 11,000 psi and feature ac output.
Precision
Aerospace
If you have ever traveled by air, chances are
you’ve flown with equipment by Honeywell
Sensing and Control. We have been meeting
demanding aerospace applications since 1952
under these brand names:
Courter
Bendix
Eclipse-Pioneer
Sperry
MICRO SWITCH
Valetin
PRECISION AEROSPACE
196 www.honeywell.com/sensing
PRODUCT OVERVIEW
HONEYWELL SENSING AND CONTROL PRODUCTS
Selecting the right sensor or switch for your application has never been easier. Honeywell Sensing and Control has one of the broadest product ranges
of any supplier in the world, and the depth of our technology and product lines ensure you are able to find the right product for most applications.
We also have the outstanding technical support staff and responsive service to back this up, so you can always find what you need, when you need it.
We aim to supply on time, every time, anywhere in the world.
Honeywell - Taking the risk and high costs out of system critical sensing and control.
You can find out more about Honeywell’s extensive product range by visiting our website at
www.honeywell.com/sensing
There you can browse our interactive catalogue and discover our full range of products for use in Industrial, Automotive, Aviation, Transportation,
Motion Control, Medical applications and more. Some of our more popular product families include:
Accelerometers
Utilizing Quartz Flexure and Resonating Beam technologies for inertial,
control, and industrial applications.
Automotive Sensors
Speed and position sensors for engine management, wheel speed sensors,
and position sensors for comfort, convenience, and motor control
applications.
Basic Switches
Standard size, miniature, subminiature, hermetically sealed, and high
temperature snap-action switches for applications requiring compactness,
light weight, accurate repeatability and long life.
Current Sensors
Adjustable linear, null balance, digital, and linear output current sensors for
monitoring ac or dc current.
Electronic and Electromechanical Safety products for
Machine Safeguarding
Safety light curtains, laser scanners, mats, door interrupt devices and single
and multi-beam optoelectronic devices for industrial machine safety. Safety
interlock switches, limit switches and cable-pull limit switches for industrial
machine safety. Safety control modules for industrial machine safety.
Environment Sealed Switches and Sensors
Designed for use in the harsh environments encountered in aerospace,
transportation, ordnance and marine applications.
Fibre Optic Sensors
Active optoelectronic components and sub-assemblies (LEDs/transmitters,
fiber-DIPs, receivers and modules) for the datacom market.
Force Sensors
Enhanced reliability and performance in compact commercial grade
packaging.
Hour Meters
Honeywell’s Hobbs brand products are designed for elapsed time
measurement for testing, leasing, maintenance and warranty programs.
The meter family includes LCD, Counter, Battery Controller, AC Electro-
Mechanical and DC Electro-Mechanical.
Humidity Sensors
Relative humidity/temperature and relative humidity sensors in chemically
resistant packages to accommodate harsh environments.
Infrared Sensors
Optoelectronic standard infrared emitting diodes (IREDs), sensors and
assemblies for object presence, limit, and motion sensing, position
encoding, and movement counting.
Limit and Enclosed Switches
Heavy duty limit switches, enclosed switches (precision snap-acting switches
sealed in rugged metal housing) and sealed and explosion-proof switches.
Liquid Level Sensors
Basic and industrial (designed for harsh industrial environments) liquid level
sensors used to indicate the presence or absence of liquid.
Mass Airflow Sensors
Amplified and unamplified microbridge mass airflow sensors provide a
sensitive and fast response to the flow of air or other gas over the chip.
Off-Highway Vehicular Lighting
Honeywell’s Hobbs brand halogen sealed beams, composites, custom
designer lights, specialty lighting and indicator modules for vehicular and
non-vehicular applications.
Position Sensors
Hall-effect, magnetoresistive, and potentiometric devices for detecting the
presence of a magnetic field or linear and rotary position.
197
www.honeywell.com/sensing
Pressure Sensors
A wide offering of media-isolated pressure sensors with multiple
pressure ports and electrical signals for a variety of potential applications
including the monitoring and control of corrosive media in aggressive
environments.
Proximity Sensors
Severe environment proximity sensors designed for use in applications
with particularly demanding requirements on temperature, vibration,
shock, and EMI/lightning resistance.
Pushbuttons, Keyswitches and Indicators
MICRO SWITCH brand pushbuttons, keyswitches, and indicators for use
anywhere manual operation is desired.
Railway Sensors and Control Systems
Railwheel proximity sensors, interface modules, train departure control
systems, solid state sensors, pressure sensors and electromechanical
switches for potential on-board and off-board rail industry applications.
Relays
General-purpose power relays and relay sockets designed for a wide range of
applications that require stability and reliability.
Resolvers
Absolute position sensors which provides high angular accuracy, high
resolution and repeatability under severe environmental conditions.
Temperature Sensors
Platinum- and silicon-based thin film resistance temperature devices (RTDs)
for applications that require small package size, accuracy, and linear outputs.
Thermal Products
Bimetal thermostats, Discrete and Packaged Thermistors, Precision Hi-Rel
Negative Temperature Coefficient (NTC) Thermistors, Thermal cut offs and
Flexible Heaters
Thermocouples, Non-contact probes and RTDs
Megopak thermocouples, thermocouples with protecting tubes,
Radiamatic/Rayotube Sensors, and the platinum RTD 100 Ohm.
Toggle and Rocker Switches
MICRO SWITCH brand toggles, rockers and paddle switches for use
anywhere manual operation is desired. Military grade and environment
sealed options are available.
Turbidity Sensors
Wash process turbidity sensors to improve product quality, minimize
ingredient consumption, and reduce wastewater discharge in commercial
and industrial bath applications.
Ultrasonic Sensors
Ultrasonic position sensors for presence/absence sensing, precision distance
sensing or tracking for areas where other sensing technologies have
difficulty, such as clear or shiny objects, foggy or particle laden air, or
splashing liquids.
VRS Speed and Timing Sensors
Completely self-powered, VRS (magnetic) sensors are simple, rugged
devices that do not require an external voltage source for operation. They are
generally used to provide speed, timing or synchronization data to a display
(or control circuitry) in the form of a pulse train.
This list of our products is not exhaustive,
so check out our full range at
www.honeywell.com/sensing
PRODUCT OVERVIEW
198 www.honeywell.com/sensing
New Technologies
and Emerging
Capabilities
Honeywell Sensing and Control is constantly developing new technologies to keep customers
competitive and at the forefront of their businesses. We excel at delivering innovative sensing and
switching solutions with best use of technology. We are able to combine our different sensing
technologies to offer differentiating solutions with enhanced precision and accuracy for the
increasingly complex needs of our customers. Our range of technologies, combined with our
application expertise and our customization capability, is what makes our sensors and switches
leaders in their fields.
Wireless Pressure and Torque Sensors
New sensing capabilities using Surface Acoustic Wave (SAW) technology
Potential Applications
Electronic power steering
Electro-hydraulic power steering
Active suspension control
Limited slip drive train controls
Transmissions
Emissions sensors
New sensing technologies to measure Exhaust gas recirculation (EGR) mass flow, In- cylinder
pressure, oxygen, particulate matter, ammonia, nitrogen oxide.
NEW TECHNOLOGIES
199
www.honeywell.com/sensing
Index
101HS1 . . . . . . . . . . . . . . . . . . . . . . 129
101TL1-21 . . . . . . . . . . . . . . . . . . . . 142
102HS1 . . . . . . . . . . . . . . . . . . . . . . 129
102TL2-2 . . . . . . . . . . . . . . . . . . . . . 141
102TL2-3 . . . . . . . . . . . . . . . . . . . . . 141
109HM1 . . . . . . . . . . . . . . . . . . . . . . 127
111SM1 . . . . . . . . . . . . . . . . . . . . . . 106
111SM2-T . . . . . . . . . . . . . . . . . . . . 106
114HM1-2 . . . . . . . . . . . . . . . . . . . . 126
1172CX12 . . . . . . . . . . . . . . . . . . . . . 65
1172CX2 . . . . . . . . . . . . . . . . . . . . . . 65
11CX12 . . . . . . . . . . . . . . . . . . . . . . . 65
11CX12E . . . . . . . . . . . . . . . . . . . . . . 65
11CX2 . . . . . . . . . . . . . . . . . . . . . . . . 65
11CX2E . . . . . . . . . . . . . . . . . . . . . . . 65
11HM1 . . . . . . . . . . . . . . . . . . . . . . . 127
11NT1-2 . . . . . . . . . . . . . . . . . . . . . 151
11NT1-3 . . . . . . . . . . . . . . . . . . . . . 151
11NT1-7 . . . . . . . . . . . . . . . . . . . . . 152
11NT1-7-NH . . . . . . . . . . . . . . . . . . 152
11SM1 . . . . . . . . . . . . . . . . . . . . . . . 106
11SM601-H4 . . . . . . . . . . . . . . . . . . 106
11SX1-T . . . . . . . . . . . . . . . . . . . . . 106
11TS115-3 . . . . . . . . . . . . . . . . . . . 156
11TS15-1 . . . . . . . . . . . . . . . . . . . . 156
11TS15-2 . . . . . . . . . . . . . . . . . . . . 156
11TS15-6 . . . . . . . . . . . . . . . . . . . . 156
11TS15-7 . . . . . . . . . . . . . . . . . . . . 156
11TS95-2 . . . . . . . . . . . . . . . . . . . . 156
11TS95-7 . . . . . . . . . . . . . . . . . . . . 156
11TW1-1L . . . . . . . . . . . . . . . . . . . . 144
11TW1-2 . . . . . . . . . . . . . . . . . . . . . 144
11TW1-3 . . . . . . . . . . . . . . . . . . . . . 144
11TW1-3D . . . . . . . . . . . . . . . . . . . . 144
11TW1-7 . . . . . . . . . . . . . . . . . . . . . 144
11TW8-2 . . . . . . . . . . . . . . . . . . . . . 144
11TW8-3 . . . . . . . . . . . . . . . . . . . . . 144
11TW8-5 . . . . . . . . . . . . . . . . . . . . . 144
11TW8-7 . . . . . . . . . . . . . . . . . . . . . 144
120000 . . . . . . . . . . . . . . . . . . . . . . 116
120001 . . . . . . . . . . . . . . . . . . . . . . 116
120002 . . . . . . . . . . . . . . . . . . . . . . 116
120003 . . . . . . . . . . . . . . . . . . . . . . 116
120004 . . . . . . . . . . . . . . . . . . . . . . 116
120005 . . . . . . . . . . . . . . . . . . . . . . 116
120006 . . . . . . . . . . . . . . . . . . . . . . 116
120007 . . . . . . . . . . . . . . . . . . . . . . 116
120008 . . . . . . . . . . . . . . . . . . . . . . 116
12HR1-S . . . . . . . . . . . . . . . . . . . . . 138
12HR8-6 . . . . . . . . . . . . . . . . . . . . . 138
12NT1-3 . . . . . . . . . . . . . . . . . . . . . 151
12PA4 . . . . . . . . . . . . . . . . . . . . . . . 158
12PA5-BK . . . . . . . . . . . . . . . . . . . . 158
12PA5-BL . . . . . . . . . . . . . . . . . . . . 158
12PA5-G . . . . . . . . . . . . . . . . . . . . . 158
12PA5-R . . . . . . . . . . . . . . . . . . . . . 158
12PA5-W . . . . . . . . . . . . . . . . . . . . . 158
12PA5-Y . . . . . . . . . . . . . . . . . . . . . 158
12PA6 . . . . . . . . . . . . . . . . . . . . . . . 158
12SE4-T . . . . . . . . . . . . . . . . . . . . . 122
12TL1-2 . . . . . . . . . . . . . . . . . . . . . . 141
12TL1-3 . . . . . . . . . . . . . . . . . . . . . . 141
12TS115-3 . . . . . . . . . . . . . . . . . . . 156
12TS15-2 . . . . . . . . . . . . . . . . . . . . 156
12TS15-3 . . . . . . . . . . . . . . . . . . . . 156
12TS15-7 . . . . . . . . . . . . . . . . . . . . 156
12TS95-10 . . . . . . . . . . . . . . . . . . . 156
12TS95-3 . . . . . . . . . . . . . . . . . . . . 156
12TW1-1 . . . . . . . . . . . . . . . . . . . . . 144
12TW1-3 . . . . . . . . . . . . . . . . . . . . . 144
12TW1-3D . . . . . . . . . . . . . . . . . . . . 144
12TW1-50 . . . . . . . . . . . . . . . . . . . . 144
12TW1-50M . . . . . . . . . . . . . . . . . . 144
12TW1-7 . . . . . . . . . . . . . . . . . . . . . 144
12TW1-70 . . . . . . . . . . . . . . . . . . . . 144
12TW29-1 . . . . . . . . . . . . . . . . . . . . 144
12TW29-7 . . . . . . . . . . . . . . . . . . . . 144
12TW75-3 . . . . . . . . . . . . . . . . . . . . 144
12TW75-7 . . . . . . . . . . . . . . . . . . . . 144
12TW8-3 . . . . . . . . . . . . . . . . . . . . . 144
12TW8-7 . . . . . . . . . . . . . . . . . . . . . 144
13HM1 . . . . . . . . . . . . . . . . . . . . . . . 127
14CE1-1 . . . . . . . . . . . . . . . . . . . . . . 24
14CE1-1A . . . . . . . . . . . . . . . . . . . . . 24
14CE1-1G . . . . . . . . . . . . . . . . . . . . . 24
14CE1-2 . . . . . . . . . . . . . . . . . . . . . . 24
14CE1-3 . . . . . . . . . . . . . . . . . . . . . . 24
14CE1-3A . . . . . . . . . . . . . . . . . . . . . 24
14CE1-3G . . . . . . . . . . . . . . . . . . . . . 24
14CE1-AQ . . . . . . . . . . . . . . . . . . . . . 24
14CE1-Q . . . . . . . . . . . . . . . . . . . . . . 24
14CE101-1 . . . . . . . . . . . . . . . . . . . . 58
14CE101-10 . . . . . . . . . . . . . . . . . . . 58
14CE101-2 . . . . . . . . . . . . . . . . . . . . 58
14CE101-3 . . . . . . . . . . . . . . . . . . . . 58
14CE101-4 . . . . . . . . . . . . . . . . . . . . 58
14CE101-5 . . . . . . . . . . . . . . . . . . . . 58
14CE101-6 . . . . . . . . . . . . . . . . . . . . 58
14CE102-1 . . . . . . . . . . . . . . . . . . . . 58
14CE102-12 . . . . . . . . . . . . . . . . . . . 58
14CE102-15 . . . . . . . . . . . . . . . . . . . 58
14CE102-3 . . . . . . . . . . . . . . . . . . . . 58
14CE102-3G . . . . . . . . . . . . . . . . . . . 58
14CE102-5 . . . . . . . . . . . . . . . . . . . . 58
14CE102-6 . . . . . . . . . . . . . . . . . . . . 58
14CE102-6G . . . . . . . . . . . . . . . . . . . 58
14CE102-8 . . . . . . . . . . . . . . . . . . . . 58
14CE103-1 . . . . . . . . . . . . . . . . . . . . 58
14CE103-3 . . . . . . . . . . . . . . . . . . . . 58
14CE118-1 . . . . . . . . . . . . . . . . . . . . 58
14CE118-10 . . . . . . . . . . . . . . . . . . . 58
14CE118-6 . . . . . . . . . . . . . . . . . . . . 58
14CE16-1 . . . . . . . . . . . . . . . . . . . . . 25
14CE16-2 . . . . . . . . . . . . . . . . . . . . . 25
14CE16-3 . . . . . . . . . . . . . . . . . . . . . 25
14CE18-1 . . . . . . . . . . . . . . . . . . . . . 24
14CE18-3 . . . . . . . . . . . . . . . . . . . . . 24
14CE18-Q . . . . . . . . . . . . . . . . . . . . . 24
14CE2-1 . . . . . . . . . . . . . . . . . . . . . . 24
14CE2-1A . . . . . . . . . . . . . . . . . . . . . 24
14CE2-1G . . . . . . . . . . . . . . . . . . . . . 24
14CE2-2 . . . . . . . . . . . . . . . . . . . . . . 24
14CE2-2A . . . . . . . . . . . . . . . . . . . . . 24
14CE2-3 . . . . . . . . . . . . . . . . . . . . . . 24
14CE2-3A . . . . . . . . . . . . . . . . . . . . . 24
14CE2-3G . . . . . . . . . . . . . . . . . . . . . 24
14CE2-AQ . . . . . . . . . . . . . . . . . . . . . 24
14CE2-Q . . . . . . . . . . . . . . . . . . . . . . 24
14CE20-1 . . . . . . . . . . . . . . . . . . . . . 25
14CE20-3 . . . . . . . . . . . . . . . . . . . . . 25
14CE3-1 . . . . . . . . . . . . . . . . . . . . . . 25
14CE3-2 . . . . . . . . . . . . . . . . . . . . . . 25
14CE3-3 . . . . . . . . . . . . . . . . . . . . . . 25
14CE31-1 . . . . . . . . . . . . . . . . . . . . . 24
14CE31-3 . . . . . . . . . . . . . . . . . . . . . 24
14CE66-1 . . . . . . . . . . . . . . . . . . . . . 24
14CE66-2 . . . . . . . . . . . . . . . . . . . . . 24
14NT1-3 . . . . . . . . . . . . . . . . . . . . . 151
14XE1 . . . . . . . . . . . . . . . . . . . . . . . 124
14XE1-T . . . . . . . . . . . . . . . . . . . . . 124
15HM2 . . . . . . . . . . . . . . . . . . . . . . . 127
15HM5 . . . . . . . . . . . . . . . . . . . . . . . 127
16CX12 . . . . . . . . . . . . . . . . . . . . . . . 65
16CX2 . . . . . . . . . . . . . . . . . . . . . . . . 65
18CX0 . . . . . . . . . . . . . . . . . . . . . . . . 65
18CX10 . . . . . . . . . . . . . . . . . . . . . . . 65
18CX10E . . . . . . . . . . . . . . . . . . . . . . 65
19HM1 . . . . . . . . . . . . . . . . . . . . . . . 127
19HM4 . . . . . . . . . . . . . . . . . . . . . . . 127
19PA137-HM . . . . . . . . . . . . . . . . . . 127
1CPSA1 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA1A . . . . . . . . . . . . . . . . . . . . 100
1CPSA1B . . . . . . . . . . . . . . . . . . . . 100
1CPSA2 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA2A . . . . . . . . . . . . . . . . . . . . 100
1CPSA2B . . . . . . . . . . . . . . . . . . . . 100
1CPSA3 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA3A . . . . . . . . . . . . . . . . . . . . 100
1CPSA3B . . . . . . . . . . . . . . . . . . . . 100
1CPSA4 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA5 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA6 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA6A . . . . . . . . . . . . . . . . . . . . 100
1CPSA6B . . . . . . . . . . . . . . . . . . . . 100
INDEX
200 www.honeywell.com/sensing
1CPSA7 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSA8 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC1 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC1A . . . . . . . . . . . . . . . . . . . . 100
1CPSC2 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC2A . . . . . . . . . . . . . . . . . . . . 100
1CPSC2B . . . . . . . . . . . . . . . . . . . . 100
1CPSC3 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC3A . . . . . . . . . . . . . . . . . . . . 100
1CPSC4 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC5 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC6 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC6A . . . . . . . . . . . . . . . . . . . . 100
1CPSC7 . . . . . . . . . . . . . . . . . . . . . . 100
1CPSC8 . . . . . . . . . . . . . . . . . . . . . . 100
1EN1-6 . . . . . . . . . . . . . . . . . . . . . . 133
1EN231-6 . . . . . . . . . . . . . . . . . . . . 133
1EN51-6 . . . . . . . . . . . . . . . . . . . . . 133
1EN61-6 . . . . . . . . . . . . . . . . . . . . . 133
1EN75-R . . . . . . . . . . . . . . . . . . . . . 134
1EN75-R3 . . . . . . . . . . . . . . . . . . . . 134
1EN76-R . . . . . . . . . . . . . . . . . . . . . 134
1EX1 . . . . . . . . . . . . . . . . . . . . . . . . . 61
1HE1-6 . . . . . . . . . . . . . . . . . . . . . . 137
1HE222-6 . . . . . . . . . . . . . . . . . . . . 137
1HS1 . . . . . . . . . . . . . . . . . . . . . . . . 129
1HS3 . . . . . . . . . . . . . . . . . . . . . . . . 128
1HS41 . . . . . . . . . . . . . . . . . . . . . . . 129
1HS6 . . . . . . . . . . . . . . . . . . . . . . . . 129
1HT1 . . . . . . . . . . . . . . . . . . . . . . . . 130
1LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 30
1LS1-4C . . . . . . . . . . . . . . . . . . . . . . 30
1LS1-L . . . . . . . . . . . . . . . . . . . . . . . 30
1LS10 . . . . . . . . . . . . . . . . . . . . . . . . 31
1LS10-4C . . . . . . . . . . . . . . . . . . . . . 31
1LS10-L . . . . . . . . . . . . . . . . . . . . . . 31
1LS131 . . . . . . . . . . . . . . . . . . . . . . . 30
1LS19 . . . . . . . . . . . . . . . . . . . . . . . . 30
1LS19-4C . . . . . . . . . . . . . . . . . . . . . 30
1LS2 . . . . . . . . . . . . . . . . . . . . . . . . . 31
1LS2-4C . . . . . . . . . . . . . . . . . . . . . . 31
1LS2-L . . . . . . . . . . . . . . . . . . . . . . . 31
1LS23 . . . . . . . . . . . . . . . . . . . . . . . . 31
1LS243 . . . . . . . . . . . . . . . . . . . . . . . 30
1LS243-4C . . . . . . . . . . . . . . . . . . . . 30
1LS3 . . . . . . . . . . . . . . . . . . . . . . . . . 30
1LS3-4C . . . . . . . . . . . . . . . . . . . . . . 30
1LS3-L . . . . . . . . . . . . . . . . . . . . . . . 30
1LS47 . . . . . . . . . . . . . . . . . . . . . . . . 31
1LS501 . . . . . . . . . . . . . . . . . . . . . . . 30
1LS53 . . . . . . . . . . . . . . . . . . . . . . . . 31
1LS56 . . . . . . . . . . . . . . . . . . . . . . . . 31
1LS58 . . . . . . . . . . . . . . . . . . . . . . . . 30
1LS59 . . . . . . . . . . . . . . . . . . . . . . . . 30
1LS6 . . . . . . . . . . . . . . . . . . . . . . . . . 30
1LS9 . . . . . . . . . . . . . . . . . . . . . . . . . 31
1NT1-1 . . . . . . . . . . . . . . . . . . . . . . 152
1NT1-2 . . . . . . . . . . . . . . . . . . . . . . 151
1NT1-2G . . . . . . . . . . . . . . . . . . . . . 151
1NT1-3 . . . . . . . . . . . . . . . . . . . . . . 151
1NT1-3-NH . . . . . . . . . . . . . . . . . . . 151
1NT1-3D . . . . . . . . . . . . . . . . . . . . . 151
1NT1-5 . . . . . . . . . . . . . . . . . . . . . . 152
1NT1-6 . . . . . . . . . . . . . . . . . . . . . . 151
1NT1-7 . . . . . . . . . . . . . . . . . . . . . . 152
1NT1-7-NH . . . . . . . . . . . . . . . . . . . 152
1NT1-7E . . . . . . . . . . . . . . . . . . . . . 152
1NT1-8 . . . . . . . . . . . . . . . . . . . . . . 151
1NT1-8-NH . . . . . . . . . . . . . . . . . . . 151
1NT20-7E . . . . . . . . . . . . . . . . . . . . 152
1NT231-7 . . . . . . . . . . . . . . . . . . . . 152
1NT91-2 . . . . . . . . . . . . . . . . . . . . . 151
1NT91-7 . . . . . . . . . . . . . . . . . . . . . 152
1SE1 . . . . . . . . . . . . . . . . . . . . . . . . 122
1SE1-T . . . . . . . . . . . . . . . . . . . . . . 122
1SE2 . . . . . . . . . . . . . . . . . . . . . . . . 122
1SE3 . . . . . . . . . . . . . . . . . . . . . . . . 122
1SE61-T . . . . . . . . . . . . . . . . . . . . . 122
1SE7 . . . . . . . . . . . . . . . . . . . . . . . . 122
1SX1-T . . . . . . . . . . . . . . . . . . . . . . 106
1TB1-2 . . . . . . . . . . . . . . . . . . . . . . 105
1TL1-1 . . . . . . . . . . . . . . . . . . . . . . . 142
1TL1-1A . . . . . . . . . . . . . . . . . . . . . 142
1TL1-2 . . . . . . . . . . . . . . . . . . . . . . . 141
1TL1-21 . . . . . . . . . . . . . . . . . . . . . . 142
1TL1-2D . . . . . . . . . . . . . . . . . . . . . 141
1TL1-2G . . . . . . . . . . . . . . . . . . . . . 141
1TL1-3 . . . . . . . . . . . . . . . . . . . . . . . 141
1TL1-3D . . . . . . . . . . . . . . . . . . . . . 141
1TL1-5 . . . . . . . . . . . . . . . . . . . . . . . 142
1TL1-6 . . . . . . . . . . . . . . . . . . . . . . . 141
1TL1-61 . . . . . . . . . . . . . . . . . . . . . . 142
1TL1-7 . . . . . . . . . . . . . . . . . . . . . . . 142
1TL1-7E . . . . . . . . . . . . . . . . . . . . . . 142
1TL1-8 . . . . . . . . . . . . . . . . . . . . . . . 141
1TL1-8F . . . . . . . . . . . . . . . . . . . . . . 141
1TL150-3D . . . . . . . . . . . . . . . . . . . 141
1TP1-6 . . . . . . . . . . . . . . . . . . . . . . 158
1TP12-7 . . . . . . . . . . . . . . . . . . . . . 158
1TP201-7 . . . . . . . . . . . . . . . . . . . . 158
1TP8-2 . . . . . . . . . . . . . . . . . . . . . . 158
1TP8-3 . . . . . . . . . . . . . . . . . . . . . . 158
1TP8-7 . . . . . . . . . . . . . . . . . . . . . . 158
1TW1-3 . . . . . . . . . . . . . . . . . . . . . . 144
1XE1 . . . . . . . . . . . . . . . . . . . . . . . . 124
1XE1-T . . . . . . . . . . . . . . . . . . . . . . 124
1XE201 . . . . . . . . . . . . . . . . . . . . . . 124
1XE3 . . . . . . . . . . . . . . . . . . . . . . . . 124
1XE301 . . . . . . . . . . . . . . . . . . . . . . 124
1XE401-6 . . . . . . . . . . . . . . . . . . . . 124
1XE401-T . . . . . . . . . . . . . . . . . . . . 124
1XE99-T . . . . . . . . . . . . . . . . . . . . . 124
20001 . . . . . . . . . . . . . . . . . . . . . . . 182
20007 . . . . . . . . . . . . . . . . . . . . . . . 182
20016 . . . . . . . . . . . . . . . . . . . . . . . 182
20017 . . . . . . . . . . . . . . . . . . . . . . . 182
20018 . . . . . . . . . . . . . . . . . . . . . . . 182
20019 . . . . . . . . . . . . . . . . . . . . . . . 182
2001EN1-6 . . . . . . . . . . . . . . . . . . . 134
20028 . . . . . . . . . . . . . . . . . . . . . . . 182
20029 . . . . . . . . . . . . . . . . . . . . . . . 182
20HM1-1 . . . . . . . . . . . . . . . . . . . . . 126
21CX14 . . . . . . . . . . . . . . . . . . . . . . . 65
21CX4 . . . . . . . . . . . . . . . . . . . . . . . . 65
21EN75-R1 . . . . . . . . . . . . . . . . . . . 134
21EN9-6 . . . . . . . . . . . . . . . . . . . . . 134
22HR1-S . . . . . . . . . . . . . . . . . . . . . 138
24CE1-S12B . . . . . . . . . . . . . . . . . . . 27
24CE1-S2 . . . . . . . . . . . . . . . . . . . . . 27
24CE1-S2A . . . . . . . . . . . . . . . . . . . . 27
24CE1-S2B . . . . . . . . . . . . . . . . . . . . 27
24CE1-S3 . . . . . . . . . . . . . . . . . . . . . 27
24CE1-S6 . . . . . . . . . . . . . . . . . . . . . 27
24CE1-Y1A . . . . . . . . . . . . . . . . . . . . 27
24CE1-Y2 . . . . . . . . . . . . . . . . . . . . . 27
24CE1-Y3 . . . . . . . . . . . . . . . . . . . . . 27
24CE16-S1 . . . . . . . . . . . . . . . . . . . . 27
24CE16-Y1 . . . . . . . . . . . . . . . . . . . . 27
24CE16-Y6 . . . . . . . . . . . . . . . . . . . . 27
24CE2-S1 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-S2 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-S2A . . . . . . . . . . . . . . . . . . . . 27
24CE2-S2B . . . . . . . . . . . . . . . . . . . . 27
24CE2-S3 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-S6 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-T2 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-Y1 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-Y2 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-Y2A . . . . . . . . . . . . . . . . . . . . 27
24CE2-Y4 . . . . . . . . . . . . . . . . . . . . . 27
24CE2-Y6A . . . . . . . . . . . . . . . . . . . . 27
24CE28-S2 . . . . . . . . . . . . . . . . . . . . 28
24CE3-S2 . . . . . . . . . . . . . . . . . . . . . 28
24CE3-Y1 . . . . . . . . . . . . . . . . . . . . . 28
24CE3-Y2 . . . . . . . . . . . . . . . . . . . . . 28
24CE31-S1 . . . . . . . . . . . . . . . . . . . . 28
24CE31-S2 . . . . . . . . . . . . . . . . . . . . 28
24CE31-S2B . . . . . . . . . . . . . . . . . . . 28
24CE31-S5 . . . . . . . . . . . . . . . . . . . . 28
24CE31-Y1 . . . . . . . . . . . . . . . . . . . . 28
24CE31-Y2 . . . . . . . . . . . . . . . . . . . . 28
24CE31-Y3 . . . . . . . . . . . . . . . . . . . . 28
24CE55-S1 . . . . . . . . . . . . . . . . . . . . 28
24CE55-S2 . . . . . . . . . . . . . . . . . . . . 28
24CE55-Y1 . . . . . . . . . . . . . . . . . . . . 28
24CX12 . . . . . . . . . . . . . . . . . . . . . . . 65
24CX2 . . . . . . . . . . . . . . . . . . . . . . . . 65
25ET1-T-F . . . . . . . . . . . . . . . . . . . . 148
INDEX
201
www.honeywell.com/sensing
25ET117-T . . . . . . . . . . . . . . . . . . . . 148
25ET61-6 . . . . . . . . . . . . . . . . . . . . . 148
25ET61-S . . . . . . . . . . . . . . . . . . . . 148
25ET61-S-F . . . . . . . . . . . . . . . . . . . 148
25ET61-T . . . . . . . . . . . . . . . . . . . . . 148
25ET62-6 . . . . . . . . . . . . . . . . . . . . . 148
25ET64-6 . . . . . . . . . . . . . . . . . . . . . 148
26900 . . . . . . . . . . . . . . . . . . . . . . . 117
26901 . . . . . . . . . . . . . . . . . . . . . . . 117
26902 . . . . . . . . . . . . . . . . . . . . . . . 117
26903 . . . . . . . . . . . . . . . . . . . . . . . 117
26904 . . . . . . . . . . . . . . . . . . . . . . . 117
26905 . . . . . . . . . . . . . . . . . . . . . . . 117
26906 . . . . . . . . . . . . . . . . . . . . . . . 117
26907 . . . . . . . . . . . . . . . . . . . . . . . 117
26908 . . . . . . . . . . . . . . . . . . . . . . . 117
26909 . . . . . . . . . . . . . . . . . . . . . . . 117
26911 . . . . . . . . . . . . . . . . . . . . . . . 117
26912 . . . . . . . . . . . . . . . . . . . . . . . 117
26913 . . . . . . . . . . . . . . . . . . . . . . . 117
26914 . . . . . . . . . . . . . . . . . . . . . . . 117
26CX4 . . . . . . . . . . . . . . . . . . . . . . . . 65
26ET1-R-F . . . . . . . . . . . . . . . . . . . . 148
26ET1-T-F . . . . . . . . . . . . . . . . . . . . 148
26ET107-T . . . . . . . . . . . . . . . . . . . . 148
26ET61-T . . . . . . . . . . . . . . . . . . . . . 148
26ET65-T . . . . . . . . . . . . . . . . . . . . . 148
27ET118-T2-N . . . . . . . . . . . . . . . . . 148
27ET2-6-E . . . . . . . . . . . . . . . . . . . . 148
27ET61-T . . . . . . . . . . . . . . . . . . . . . 148
27ET61-T-E . . . . . . . . . . . . . . . . . . . 148
27ET71-T . . . . . . . . . . . . . . . . . . . . . 148
27ET71-T-E . . . . . . . . . . . . . . . . . . . 148
28000 . . . . . . . . . . . . . . . . . . . . . . . 183
28002 . . . . . . . . . . . . . . . . . . . . . . . 183
28004 . . . . . . . . . . . . . . . . . . . . . . . 183
28006 . . . . . . . . . . . . . . . . . . . . . . . 183
28030 . . . . . . . . . . . . . . . . . . . . . . . 183
281CX12 . . . . . . . . . . . . . . . . . . . . . . 65
281CX2 . . . . . . . . . . . . . . . . . . . . . . . 65
29ET3 . . . . . . . . . . . . . . . . . . . . . . . 148
2CPSA1A1 . . . . . . . . . . . . . . . . . . . 101
2CPSA1A1A . . . . . . . . . . . . . . . . . . 101
2CPSA1A1B . . . . . . . . . . . . . . . . . . 101
2CPSA1A2 . . . . . . . . . . . . . . . . . . . 101
2CPSA1A2A . . . . . . . . . . . . . . . . . . 101
2CPSA1A2B . . . . . . . . . . . . . . . . . . 101
2CPSA1A3 . . . . . . . . . . . . . . . . . . . 101
2CPSA1A3A . . . . . . . . . . . . . . . . . . 101
2CPSA1A3B . . . . . . . . . . . . . . . . . . 101
2CPSA1B1 . . . . . . . . . . . . . . . . . . . 101
2CPSA1B1A . . . . . . . . . . . . . . . . . . 101
2CPSA1B1B . . . . . . . . . . . . . . . . . . 101
2CPSA1B2 . . . . . . . . . . . . . . . . . . . 101
2CPSA1B2A . . . . . . . . . . . . . . . . . . 101
2CPSA1B2B . . . . . . . . . . . . . . . . . . 101
2CPSA1B3 . . . . . . . . . . . . . . . . . . . 101
2CPSA1B3A . . . . . . . . . . . . . . . . . . 101
2CPSA1B3B . . . . . . . . . . . . . . . . . . 101
2CPSA2A1 . . . . . . . . . . . . . . . . . . . 101
2CPSA2A1A . . . . . . . . . . . . . . . . . . 101
2CPSA2A1B . . . . . . . . . . . . . . . . . . 101
2CPSA2A2 . . . . . . . . . . . . . . . . . . . 101
2CPSA2A2A . . . . . . . . . . . . . . . . . . 101
2CPSA2A2B . . . . . . . . . . . . . . . . . . 101
2CPSA2A3 . . . . . . . . . . . . . . . . . . . 101
2CPSA2A3A . . . . . . . . . . . . . . . . . . 101
2CPSA2A3B . . . . . . . . . . . . . . . . . . 101
2CPSA2B1 . . . . . . . . . . . . . . . . . . . 101
2CPSA2B1A . . . . . . . . . . . . . . . . . . 101
2CPSA2B1B . . . . . . . . . . . . . . . . . . 101
2CPSC1A1 . . . . . . . . . . . . . . . . . . . 101
2CPSC1A1A . . . . . . . . . . . . . . . . . . 101
2CPSC1A2 . . . . . . . . . . . . . . . . . . . 101
2CPSC1A2A . . . . . . . . . . . . . . . . . . 101
2CPSC1A3 . . . . . . . . . . . . . . . . . . . 101
2CPSC1A3A . . . . . . . . . . . . . . . . . . 101
2CPSC1D1A . . . . . . . . . . . . . . . . . . 101
2EN1-6 . . . . . . . . . . . . . . . . . . . . . . 133
2EX1 . . . . . . . . . . . . . . . . . . . . . . . . . 61
2HM19-1 . . . . . . . . . . . . . . . . . . . . . 126
2HM19-5 . . . . . . . . . . . . . . . . . . . . . 126
2HT1 . . . . . . . . . . . . . . . . . . . . . . . . 130
2LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 32
2LS1-4C . . . . . . . . . . . . . . . . . . . . . . 32
2LS1-L . . . . . . . . . . . . . . . . . . . . . . . 32
2LS111 . . . . . . . . . . . . . . . . . . . . . . . 32
2NT1-1 . . . . . . . . . . . . . . . . . . . . . . 152
2NT1-1-NH . . . . . . . . . . . . . . . . . . . 152
2NT1-10 . . . . . . . . . . . . . . . . . . . . . 152
2NT1-2 . . . . . . . . . . . . . . . . . . . . . . 151
2NT1-3 . . . . . . . . . . . . . . . . . . . . . . 151
2NT1-3-NH . . . . . . . . . . . . . . . . . . . 151
2NT1-5 . . . . . . . . . . . . . . . . . . . . . . 152
2NT1-50 . . . . . . . . . . . . . . . . . . . . . 152
2NT1-7 . . . . . . . . . . . . . . . . . . . . . . 152
2NT1-7-NH . . . . . . . . . . . . . . . . . . . 152
2NT1-70 . . . . . . . . . . . . . . . . . . . . . 152
2NT1-8 . . . . . . . . . . . . . . . . . . . . . . 151
2NT1-8-NH . . . . . . . . . . . . . . . . . . . 151
2NT231-7 . . . . . . . . . . . . . . . . . . . . 152
2NT889-70 . . . . . . . . . . . . . . . . . . . 152
2NT91-7 . . . . . . . . . . . . . . . . . . . . . 152
2TL1-1 . . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-10 . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-10A . . . . . . . . . . . . . . . . . . . . 142
2TL1-12 . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-1A . . . . . . . . . . . . . . . . . . . . . 142
2TL1-2 . . . . . . . . . . . . . . . . . . . . . . . 141
2TL1-21 . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-2D . . . . . . . . . . . . . . . . . . . . . 141
2TL1-3 . . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-31K . . . . . . . . . . . . . . . . . . . . 142
2TL1-3D . . . . . . . . . . . . . . . . . . . . . 142
2TL1-3G . . . . . . . . . . . . . . . . . . . . . 142
2TL1-5 . . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-50 . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-56 . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-6 . . . . . . . . . . . . . . . . . . . . . . . 141
2TL1-7 . . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-70 . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-70E . . . . . . . . . . . . . . . . . . . . . 142
2TL1-8 . . . . . . . . . . . . . . . . . . . . . . . 142
2TL1-8F . . . . . . . . . . . . . . . . . . . . . . 142
2TP1-7 . . . . . . . . . . . . . . . . . . . . . . 158
2TP12-7 . . . . . . . . . . . . . . . . . . . . . 158
2TP216-7 . . . . . . . . . . . . . . . . . . . . 158
2TP216-8 . . . . . . . . . . . . . . . . . . . . 158
2TP7-3 . . . . . . . . . . . . . . . . . . . . . . 158
311SX5-T . . . . . . . . . . . . . . . . . . . . 106
31EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
31EN11-6 . . . . . . . . . . . . . . . . . . . . 135
31NT91-1 . . . . . . . . . . . . . . . . . . . . 154
31NT91-2 . . . . . . . . . . . . . . . . . . . . 153
31NT91-3 . . . . . . . . . . . . . . . . . . . . 153
31NT91-6 . . . . . . . . . . . . . . . . . . . . 153
31NT91-7 . . . . . . . . . . . . . . . . . . . . 154
32EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
32EN11-6 . . . . . . . . . . . . . . . . . . . . 135
32NT291-3G . . . . . . . . . . . . . . . . . . 153
32NT291-5E . . . . . . . . . . . . . . . . . . 154
32NT91-1 . . . . . . . . . . . . . . . . . . . . 154
32NT91-2 . . . . . . . . . . . . . . . . . . . . 153
32NT91-3 . . . . . . . . . . . . . . . . . . . . 153
32NT91-7 . . . . . . . . . . . . . . . . . . . . 154
32NT91-7-NH . . . . . . . . . . . . . . . . . 154
32NT94-70L . . . . . . . . . . . . . . . . . . 154
33EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
33EN11-6 . . . . . . . . . . . . . . . . . . . . 135
34EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
34EN11-6 . . . . . . . . . . . . . . . . . . . . 135
3EN1-6 . . . . . . . . . . . . . . . . . . . . . . 133
3HT1 . . . . . . . . . . . . . . . . . . . . . . . . 130
3LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 32
3LS1-4C . . . . . . . . . . . . . . . . . . . . . . 32
402EN1-6 . . . . . . . . . . . . . . . . . . . . 136
404EN1-6 . . . . . . . . . . . . . . . . . . . . 136
41EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
42EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
44EN1-6 . . . . . . . . . . . . . . . . . . . . . 135
4EN1-6 . . . . . . . . . . . . . . . . . . . . . . 133
4EX1-3 . . . . . . . . . . . . . . . . . . . . . . . 61
4HS4-118 . . . . . . . . . . . . . . . . . . . . 129
4LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 32
4LS1-4C . . . . . . . . . . . . . . . . . . . . . . 32
4NT1-1 . . . . . . . . . . . . . . . . . . . . . . 152
4NT1-1A . . . . . . . . . . . . . . . . . . . . . 152
4NT1-3 . . . . . . . . . . . . . . . . . . . . . . 151
INDEX
202 www.honeywell.com/sensing
4SE1 . . . . . . . . . . . . . . . . . . . . . . . . 122
4TL1-2 . . . . . . . . . . . . . . . . . . . . . . . 141
4TL1-3 . . . . . . . . . . . . . . . . . . . . . . . 141
4TL1-3D . . . . . . . . . . . . . . . . . . . . . 141
4TL1-7 . . . . . . . . . . . . . . . . . . . . . . . 142
4TL1-8 . . . . . . . . . . . . . . . . . . . . . . . 141
4XE1 . . . . . . . . . . . . . . . . . . . . . . . . 124
5LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 32
5LS1-4C . . . . . . . . . . . . . . . . . . . . . . 32
5LS1-L . . . . . . . . . . . . . . . . . . . . . . . 32
5SE1 . . . . . . . . . . . . . . . . . . . . . . . . 122
5XE1 . . . . . . . . . . . . . . . . . . . . . . . . 124
602EN1-6 . . . . . . . . . . . . . . . . . . . . 136
602EN222-6 . . . . . . . . . . . . . . . . . . 136
602HE1-6 . . . . . . . . . . . . . . . . . . . . 137
602HE106-6 . . . . . . . . . . . . . . . . . . 137
604EN1-6 . . . . . . . . . . . . . . . . . . . . 136
604EN222-6 . . . . . . . . . . . . . . . . . . 136
604HE1-6 . . . . . . . . . . . . . . . . . . . . 137
61NT1-7 . . . . . . . . . . . . . . . . . . . . . 152
622EN1-6 . . . . . . . . . . . . . . . . . . . . 136
622EN222-6 . . . . . . . . . . . . . . . . . . 136
622HE1-6 . . . . . . . . . . . . . . . . . . . . 137
624EN1-6 . . . . . . . . . . . . . . . . . . . . 136
624EN222-6 . . . . . . . . . . . . . . . . . . 136
624HE1-6 . . . . . . . . . . . . . . . . . . . . 137
64AT22-3 . . . . . . . . . . . . . . . . . . . . . 146
64AT34-7E . . . . . . . . . . . . . . . . . . . . 146
6AT124-T . . . . . . . . . . . . . . . . . . . . . 146
6HM1-1 . . . . . . . . . . . . . . . . . . . . . . 126
6LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 31
6LS1-4C . . . . . . . . . . . . . . . . . . . . . . 31
6LS2 . . . . . . . . . . . . . . . . . . . . . . . . . 31
6LS2-L . . . . . . . . . . . . . . . . . . . . . . . 31
6LS3 . . . . . . . . . . . . . . . . . . . . . . . . . 31
6PA102 . . . . . . . . . . . . . . . . . . . . . . . 72
6PA127-EX . . . . . . . . . . . . . . . . . . . . 72
6PA130-EX . . . . . . . . . . . . . . . . . . . . 72
6PA131-EX . . . . . . . . . . . . . . . . . . . . 72
6PA136-EX . . . . . . . . . . . . . . . . . . . . 72
6PA138-EX . . . . . . . . . . . . . . . . . . . . 72
6PA142-EX . . . . . . . . . . . . . . . . . . . . 72
6PA144 . . . . . . . . . . . . . . . . . . . . . . . 72
6PA204-EX . . . . . . . . . . . . . . . . . . . . 72
6PA5-EX . . . . . . . . . . . . . . . . . . . . . . 72
6PA57 . . . . . . . . . . . . . . . . . . . . . . . . 73
6PA63 . . . . . . . . . . . . . . . . . . . . . . . . 72
6PA69 . . . . . . . . . . . . . . . . . . . . . . . . 72
6PA80 . . . . . . . . . . . . . . . . . . . . . . . . 72
6PA82 . . . . . . . . . . . . . . . . . . . . . . . . 72
6SX7-T . . . . . . . . . . . . . . . . . . . . . . 106
71017 . . . . . . . . . . . . . . . . . . . . . . . 190
71723 . . . . . . . . . . . . . . . . . . . . . . . 192
71792 . . . . . . . . . . . . . . . . . . . . . . . 190
71794 . . . . . . . . . . . . . . . . . . . . . . . 190
71898 . . . . . . . . . . . . . . . . . . . . . . . 189
71902 . . . . . . . . . . . . . . . . . . . . . . . 189
71915 . . . . . . . . . . . . . . . . . . . . . . . 189
72108 . . . . . . . . . . . . . . . . . . . . . . . 192
72408 . . . . . . . . . . . . . . . . . . . . . . . 190
72530 . . . . . . . . . . . . . . . . . . . . . . . 192
72540 . . . . . . . . . . . . . . . . . . . . . . . 189
72541 . . . . . . . . . . . . . . . . . . . . . . . 190
72542 . . . . . . . . . . . . . . . . . . . . . . . 189
72543 . . . . . . . . . . . . . . . . . . . . . . . 190
72544 . . . . . . . . . . . . . . . . . . . . . . . 189
72545 . . . . . . . . . . . . . . . . . . . . . . . 190
72656 . . . . . . . . . . . . . . . . . . . . . . . 192
72666 . . . . . . . . . . . . . . . . . . . . . . . 192
72715 . . . . . . . . . . . . . . . . . . . . . . . 192
72716 . . . . . . . . . . . . . . . . . . . . . . . 192
72717 . . . . . . . . . . . . . . . . . . . . . . . 192
72718 . . . . . . . . . . . . . . . . . . . . . . . 192
72719 . . . . . . . . . . . . . . . . . . . . . . . 192
72720 . . . . . . . . . . . . . . . . . . . . . . . 192
72728 . . . . . . . . . . . . . . . . . . . . . . . 192
72801 . . . . . . . . . . . . . . . . . . . . . . . 190
73468 . . . . . . . . . . . . . . . . . . . . . . . 190
73469 . . . . . . . . . . . . . . . . . . . . . . . 190
73761 . . . . . . . . . . . . . . . . . . . . . . . 189
73763 . . . . . . . . . . . . . . . . . . . . . . . 189
73764 . . . . . . . . . . . . . . . . . . . . . . . 189
73804 . . . . . . . . . . . . . . . . . . . . . . . 190
74041 . . . . . . . . . . . . . . . . . . . . . . . 192
76051 . . . . . . . . . . . . . . . . . . . . . . . 114
76052 . . . . . . . . . . . . . . . . . . . . . . . 114
76053 . . . . . . . . . . . . . . . . . . . . . . . 114
76054 . . . . . . . . . . . . . . . . . . . . . . . 114
76055 . . . . . . . . . . . . . . . . . . . . . . . 114
76061 . . . . . . . . . . . . . . . . . . . . . . . 114
76062 . . . . . . . . . . . . . . . . . . . . . . . 114
76063 . . . . . . . . . . . . . . . . . . . . . . . 114
76064 . . . . . . . . . . . . . . . . . . . . . . . 114
76065 . . . . . . . . . . . . . . . . . . . . . . . 114
76575 . . . . . . . . . . . . . . . . . . . . . . . 114
76576 . . . . . . . . . . . . . . . . . . . . . . . 114
76577 . . . . . . . . . . . . . . . . . . . . . . . 114
76578 . . . . . . . . . . . . . . . . . . . . . . . 114
77342 . . . . . . . . . . . . . . . . . . . . . . . 115
77343 . . . . . . . . . . . . . . . . . . . . . . . 115
78628 . . . . . . . . . . . . . . . . . . . . . . . 114
78632 . . . . . . . . . . . . . . . . . . . . . . . 114
78813 . . . . . . . . . . . . . . . . . . . . . . . 115
78815 . . . . . . . . . . . . . . . . . . . . . . . 115
79700 . . . . . . . . . . . . . . . . . . . . . . . 115
79702 . . . . . . . . . . . . . . . . . . . . . . . 115
79704 . . . . . . . . . . . . . . . . . . . . . . . 115
79708 . . . . . . . . . . . . . . . . . . . . . . . 115
79710 . . . . . . . . . . . . . . . . . . . . . . . 115
79718 . . . . . . . . . . . . . . . . . . . . . . . 115
79719 . . . . . . . . . . . . . . . . . . . . . . . 115
79720 . . . . . . . . . . . . . . . . . . . . . . . 115
79721 . . . . . . . . . . . . . . . . . . . . . . . 115
79722 . . . . . . . . . . . . . . . . . . . . . . . 115
79723 . . . . . . . . . . . . . . . . . . . . . . . 115
79809 . . . . . . . . . . . . . . . . . . . . . . . 188
7SE1 . . . . . . . . . . . . . . . . . . . . . . . . 122
80260 . . . . . . . . . . . . . . . . . . . . . . . 186
80262 . . . . . . . . . . . . . . . . . . . . . . . 186
80279 . . . . . . . . . . . . . . . . . . . . . . . 188
80350 . . . . . . . . . . . . . . . . . . . . . . . 188
80413 . . . . . . . . . . . . . . . . . . . . . . . 191
80438 . . . . . . . . . . . . . . . . . . . . . . . 186
80510 . . . . . . . . . . . . . . . . . . . . . . . 191
80876 . . . . . . . . . . . . . . . . . . . . . . . 186
80877 . . . . . . . . . . . . . . . . . . . . . . . 188
80909 . . . . . . . . . . . . . . . . . . . . . . . 186
80910 . . . . . . . . . . . . . . . . . . . . . . . 186
81248 . . . . . . . . . . . . . . . . . . . . . . . 186
81426 . . . . . . . . . . . . . . . . . . . . . . . 186
81521 . . . . . . . . . . . . . . . . . . . . . . . 186
81601 . . . . . . . . . . . . . . . . . . . . . . . 188
81705 . . . . . . . . . . . . . . . . . . . . . . . 188
81758 . . . . . . . . . . . . . . . . . . . . . . . 186
81CX14 . . . . . . . . . . . . . . . . . . . . . . . 65
81CX2 . . . . . . . . . . . . . . . . . . . . . . . . 65
81CX4 . . . . . . . . . . . . . . . . . . . . . . . . 65
82320 . . . . . . . . . . . . . . . . . . . . . . . 180
82400 . . . . . . . . . . . . . . . . . . . . . . . 181
82401 . . . . . . . . . . . . . . . . . . . . . . . 181
82404 . . . . . . . . . . . . . . . . . . . . . . . 182
82416 . . . . . . . . . . . . . . . . . . . . . . . 181
82570 . . . . . . . . . . . . . . . . . . . . . . . 188
83298 . . . . . . . . . . . . . . . . . . . . . . . 116
83299 . . . . . . . . . . . . . . . . . . . . . . . 116
83301 . . . . . . . . . . . . . . . . . . . . . . . 116
83302 . . . . . . . . . . . . . . . . . . . . . . . 116
83304 . . . . . . . . . . . . . . . . . . . . . . . 116
83305 . . . . . . . . . . . . . . . . . . . . . . . 116
83307 . . . . . . . . . . . . . . . . . . . . . . . 116
83308 . . . . . . . . . . . . . . . . . . . . . . . 116
83310 . . . . . . . . . . . . . . . . . . . . . . . 116
83311 . . . . . . . . . . . . . . . . . . . . . . . 116
84105 . . . . . . . . . . . . . . . . . . . . . . . 186
84467 . . . . . . . . . . . . . . . . . . . . . . . 186
84760-50 . . . . . . . . . . . . . . . . . . . . . 191
84825 . . . . . . . . . . . . . . . . . . . . . . . 184
84826 . . . . . . . . . . . . . . . . . . . . . . . 184
84828 . . . . . . . . . . . . . . . . . . . . . . . 184
84829 . . . . . . . . . . . . . . . . . . . . . . . 184
84830 . . . . . . . . . . . . . . . . . . . . . . . 184
84884 . . . . . . . . . . . . . . . . . . . . . . . 188
84CX2 . . . . . . . . . . . . . . . . . . . . . . . . 65
85010 . . . . . . . . . . . . . . . . . . . . . . . 180
85093 . . . . . . . . . . . . . . . . . . . . . . . 181
85094 . . . . . . . . . . . . . . . . . . . . . . . 180
85097 . . . . . . . . . . . . . . . . . . . . . . . 180
85331 . . . . . . . . . . . . . . . . . . . . . . . 180
INDEX
203
www.honeywell.com/sensing
85342 . . . . . . . . . . . . . . . . . . . . . . . 181
85874 . . . . . . . . . . . . . . . . . . . . . . . 186
86320 . . . . . . . . . . . . . . . . . . . . . . . 188
86508 . . . . . . . . . . . . . . . . . . . . . . . 188
86835 . . . . . . . . . . . . . . . . . . . . . . . 186
87941 . . . . . . . . . . . . . . . . . . . . . . . 185
87943 . . . . . . . . . . . . . . . . . . . . . . . 185
88217-50 . . . . . . . . . . . . . . . . . . . . . 191
88432 . . . . . . . . . . . . . . . . . . . . . . . 193
88735-50 . . . . . . . . . . . . . . . . . . . . . 191
88913-50 . . . . . . . . . . . . . . . . . . . . . 191
89165 . . . . . . . . . . . . . . . . . . . . . . . 184
89444 . . . . . . . . . . . . . . . . . . . . . . . 193
89445 . . . . . . . . . . . . . . . . . . . . . . . 193
89446 . . . . . . . . . . . . . . . . . . . . . . . 193
89447 . . . . . . . . . . . . . . . . . . . . . . . 193
89448 . . . . . . . . . . . . . . . . . . . . . . . 193
89477 . . . . . . . . . . . . . . . . . . . . . . . 184
8LS1 . . . . . . . . . . . . . . . . . . . . . . . . . 33
8LS1-4C . . . . . . . . . . . . . . . . . . . . . . 33
8LS1-L . . . . . . . . . . . . . . . . . . . . . . . 33
8LS125 . . . . . . . . . . . . . . . . . . . . . . . 33
8LS125-4C . . . . . . . . . . . . . . . . . . . . 33
8LS152 . . . . . . . . . . . . . . . . . . . . . . . 33
8LS152-4C . . . . . . . . . . . . . . . . . . . . 33
8LS3 . . . . . . . . . . . . . . . . . . . . . . . . . 33
8LS3-4C . . . . . . . . . . . . . . . . . . . . . . 33
914CE1-3 . . . . . . . . . . . . . . . . . . . . . 24
914CE1-3A . . . . . . . . . . . . . . . . . . . . 24
914CE1-3G . . . . . . . . . . . . . . . . . . . . 24
914CE1-6 . . . . . . . . . . . . . . . . . . . . . 24
914CE1-6G . . . . . . . . . . . . . . . . . . . . 24
914CE1-9 . . . . . . . . . . . . . . . . . . . . . 24
914CE1-Q . . . . . . . . . . . . . . . . . . . . . 24
914CE1-Q1 . . . . . . . . . . . . . . . . . . . . 24
914CE16-3 . . . . . . . . . . . . . . . . . . . . 25
914CE16-3A . . . . . . . . . . . . . . . . . . . 25
914CE16-6 . . . . . . . . . . . . . . . . . . . . 25
914CE16-9 . . . . . . . . . . . . . . . . . . . . 25
914CE16-Q . . . . . . . . . . . . . . . . . . . . 25
914CE18-3 . . . . . . . . . . . . . . . . . . . . 24
914CE18-3A . . . . . . . . . . . . . . . . . . . 24
914CE18-6 . . . . . . . . . . . . . . . . . . . . 24
914CE18-9 . . . . . . . . . . . . . . . . . . . . 24
914CE18-9A . . . . . . . . . . . . . . . . . . . 24
914CE18-AQ1 . . . . . . . . . . . . . . . . . . 24
914CE18-Q . . . . . . . . . . . . . . . . . . . . 24
914CE18-Q1 . . . . . . . . . . . . . . . . . . . 24
914CE19-3 . . . . . . . . . . . . . . . . . . . . 24
914CE19-9 . . . . . . . . . . . . . . . . . . . . 24
914CE2-3 . . . . . . . . . . . . . . . . . . . . . 24
914CE2-3A . . . . . . . . . . . . . . . . . . . . 24
914CE2-3G . . . . . . . . . . . . . . . . . . . . 24
914CE2-6 . . . . . . . . . . . . . . . . . . . . . 24
914CE2-6A . . . . . . . . . . . . . . . . . . . . 24
914CE2-9 . . . . . . . . . . . . . . . . . . . . . 24
914CE2-AQ . . . . . . . . . . . . . . . . . . . . 24
914CE2-Q . . . . . . . . . . . . . . . . . . . . . 24
914CE2-Q1 . . . . . . . . . . . . . . . . . . . . 24
914CE20-3 . . . . . . . . . . . . . . . . . . . . 25
914CE20-6 . . . . . . . . . . . . . . . . . . . . 25
914CE20-9 . . . . . . . . . . . . . . . . . . . . 25
914CE20-Q . . . . . . . . . . . . . . . . . . . . 25
914CE22-6 . . . . . . . . . . . . . . . . . . . . 24
914CE27-Q . . . . . . . . . . . . . . . . . . . . 24
914CE28-3 . . . . . . . . . . . . . . . . . . . . 24
914CE28-6 . . . . . . . . . . . . . . . . . . . . 24
914CE28-Q . . . . . . . . . . . . . . . . . . . . 24
914CE29-3 . . . . . . . . . . . . . . . . . . . . 25
914CE29-6 . . . . . . . . . . . . . . . . . . . . 25
914CE3-3 . . . . . . . . . . . . . . . . . . . . . 25
914CE3-6 . . . . . . . . . . . . . . . . . . . . . 25
914CE3-6A . . . . . . . . . . . . . . . . . . . . 25
914CE3-9 . . . . . . . . . . . . . . . . . . . . . 25
914CE3-Q . . . . . . . . . . . . . . . . . . . . . 25
914CE3-Q1 . . . . . . . . . . . . . . . . . . . . 25
914CE31-3 . . . . . . . . . . . . . . . . . . . . 24
914CE31-6 . . . . . . . . . . . . . . . . . . . . 24
914CE55-3 . . . . . . . . . . . . . . . . . . . . 25
914CE55-3A . . . . . . . . . . . . . . . . . . . 25
914CE66-3 . . . . . . . . . . . . . . . . . . . . 24
914CE66-6 . . . . . . . . . . . . . . . . . . . . 24
924CE1-S3 . . . . . . . . . . . . . . . . . . . . 27
924CE1-S6 . . . . . . . . . . . . . . . . . . . . 27
924CE1-S9 . . . . . . . . . . . . . . . . . . . . 27
924CE1-T25A . . . . . . . . . . . . . . . . . . 27
924CE1-T3 . . . . . . . . . . . . . . . . . . . . 27
924CE1-T3A . . . . . . . . . . . . . . . . . . . 27
924CE1-T6A . . . . . . . . . . . . . . . . . . . 27
924CE1-T9 . . . . . . . . . . . . . . . . . . . . 27
924CE1-T9A . . . . . . . . . . . . . . . . . . . 27
924CE1-Y3 . . . . . . . . . . . . . . . . . . . . 27
924CE1-Y9 . . . . . . . . . . . . . . . . . . . . 27
924CE16-S3 . . . . . . . . . . . . . . . . . . . 27
924CE16-S9 . . . . . . . . . . . . . . . . . . . 27
924CE16-T3 . . . . . . . . . . . . . . . . . . . 27
924CE16-Y3 . . . . . . . . . . . . . . . . . . . 27
924CE16-Y9 . . . . . . . . . . . . . . . . . . . 27
924CE18-S6 . . . . . . . . . . . . . . . . . . . 27
924CE19-S3L1 . . . . . . . . . . . . . . . . . 27
924CE2-S15 . . . . . . . . . . . . . . . . . . . 27
924CE2-S21 . . . . . . . . . . . . . . . . . . . 27
924CE2-S3 . . . . . . . . . . . . . . . . . . . . 27
924CE2-S6 . . . . . . . . . . . . . . . . . . . . 27
924CE2-S6A . . . . . . . . . . . . . . . . . . . 27
924CE2-S9 . . . . . . . . . . . . . . . . . . . . 27
924CE2-T25 . . . . . . . . . . . . . . . . . . . 27
924CE2-T25A . . . . . . . . . . . . . . . . . . 27
924CE2-T3 . . . . . . . . . . . . . . . . . . . . 27
924CE2-T6 . . . . . . . . . . . . . . . . . . . . 27
924CE2-T9 . . . . . . . . . . . . . . . . . . . . 27
924CE2-Y3 . . . . . . . . . . . . . . . . . . . . 27
924CE2-Y9 . . . . . . . . . . . . . . . . . . . . 27
924CE28-S15 . . . . . . . . . . . . . . . . . . 28
924CE3-S3 . . . . . . . . . . . . . . . . . . . . 28
924CE3-S6 . . . . . . . . . . . . . . . . . . . . 28
924CE3-S9 . . . . . . . . . . . . . . . . . . . . 28
924CE3-T9 . . . . . . . . . . . . . . . . . . . . 28
924CE31-S6 . . . . . . . . . . . . . . . . . . . 28
924CE31-Y20 . . . . . . . . . . . . . . . . . . 28
924CE31-Y3L1 . . . . . . . . . . . . . . . . . 28
98101 . . . . . . . . . . . . . . . . . . . . . . . 178
98102 . . . . . . . . . . . . . . . . . . . . . . . 177
98103 . . . . . . . . . . . . . . . . . . . . . . . 178
98106 . . . . . . . . . . . . . . . . . . . . . . . 179
98108 . . . . . . . . . . . . . . . . . . . . . . . 179
98109 . . . . . . . . . . . . . . . . . . . . . . . 179
98110 . . . . . . . . . . . . . . . . . . . . . . . 179
98111 . . . . . . . . . . . . . . . . . . . . . . . 177
98202 . . . . . . . . . . . . . . . . . . . . . . . . 179
98301 . . . . . . . . . . . . . . . . . . . . . . . 177
98302 . . . . . . . . . . . . . . . . . . . . . . . 177
98303 . . . . . . . . . . . . . . . . . . . . . . . 179
98304 . . . . . . . . . . . . . . . . . . . . . . . 179
98311 . . . . . . . . . . . . . . . . . . . . . . . 177
98312 . . . . . . . . . . . . . . . . . . . . . . . 177
98313 . . . . . . . . . . . . . . . . . . . . . . . 179
98314 . . . . . . . . . . . . . . . . . . . . . . . 179
98321 . . . . . . . . . . . . . . . . . . . . . . . 177
98322 . . . . . . . . . . . . . . . . . . . . . . . 177
98323 . . . . . . . . . . . . . . . . . . . . . . . 179
98324 . . . . . . . . . . . . . . . . . . . . . . . 179
98706 . . . . . . . . . . . . . . . . . . . . . . . 178
98707 . . . . . . . . . . . . . . . . . . . . . . . 178
98750 . . . . . . . . . . . . . . . . . . . . . . . . 177
9HM1 . . . . . . . . . . . . . . . . . . . . . . . . 127
B
BA-2RB-A2 . . . . . . . . . . . . . . . . . . . 103
BA-2RQ1-A2 . . . . . . . . . . . . . . . . . . 103
BA-2RV-A2 . . . . . . . . . . . . . . . . . . . 104
BAF1-2RN-LH . . . . . . . . . . . . . . . . . . 42
BAF1-2RN-RH . . . . . . . . . . . . . . . . . . 42
BAF1-2RN18-LH . . . . . . . . . . . . . . . . 44
BAF1-2RN18-RH . . . . . . . . . . . . . . . . 44
BAF1-2RN2-LH . . . . . . . . . . . . . . . . . 43
BAF1-2RN2-RH . . . . . . . . . . . . . . . . . 43
BAF1-2RN28-LH . . . . . . . . . . . . . . . . 43
BAF1-2RN28-RH . . . . . . . . . . . . . . . . 43
BAF1-2RN4-LH . . . . . . . . . . . . . . . . . 44
BAF1-2RN4-RH . . . . . . . . . . . . . . . . . 44
BAF1-2RQ9-LH . . . . . . . . . . . . . . . . . 43
BAF1-2RQ9-RH . . . . . . . . . . . . . . . . . 43
BAF1-2RQN8-LH . . . . . . . . . . . . . . . . 43
BAF1-2RQN8-RH . . . . . . . . . . . . . . . . 43
BAF1-3CN18X1 . . . . . . . . . . . . . . . . . 45
BAF1-3RN2X-LH . . . . . . . . . . . . . . . . 44
BAF1-3RN2X-RH . . . . . . . . . . . . . . . . 44
INDEX
204 www.honeywell.com/sensing
BAF1-3RNX1 . . . . . . . . . . . . . . . . . . . 44
BE-2R-A4 . . . . . . . . . . . . . . . . . . . . 103
BF Series . . . . . . . . . . . . . . . . . . . . . . 34
BFL1-AW1 . . . . . . . . . . . . . . . . . . . . . 35
BFL1-AW2 . . . . . . . . . . . . . . . . . . . . . 35
BFL1-BL1 . . . . . . . . . . . . . . . . . . . . . 34
BFL1-BL2 . . . . . . . . . . . . . . . . . . . . . 35
BFL1-BL3 . . . . . . . . . . . . . . . . . . . . . 35
BFL1-BP1 . . . . . . . . . . . . . . . . . . . . . 34
BFL1-BW1 . . . . . . . . . . . . . . . . . . . . . 35
BFL1-BW3 . . . . . . . . . . . . . . . . . . . . . 35
BFL1-BW4 . . . . . . . . . . . . . . . . . . . . . 35
BFR1-BL1 . . . . . . . . . . . . . . . . . . . . . 34
BFR1-BL2 . . . . . . . . . . . . . . . . . . . . . 35
BFR1-BL3 . . . . . . . . . . . . . . . . . . . . . 35
BFR1-BP1 . . . . . . . . . . . . . . . . . . . . . 34
BFR1-BW1 . . . . . . . . . . . . . . . . . . . . . 35
BFR1-BW4 . . . . . . . . . . . . . . . . . . . . . 35
BX4A3K . . . . . . . . . . . . . . . . . . . . . . . 67
BX4C3K . . . . . . . . . . . . . . . . . . . . . . . 68
BX4C4L . . . . . . . . . . . . . . . . . . . . . . . 68
BX4D3K . . . . . . . . . . . . . . . . . . . . . . . 68
BXA3K . . . . . . . . . . . . . . . . . . . . . . . . 67
BXA4L . . . . . . . . . . . . . . . . . . . . . . . . 67
BXC4L . . . . . . . . . . . . . . . . . . . . . . . . 68
BXF3K . . . . . . . . . . . . . . . . . . . . . . . . 69
BXN3K . . . . . . . . . . . . . . . . . . . . . . . . 67
BXN4L . . . . . . . . . . . . . . . . . . . . . . . . 67
BXR3E . . . . . . . . . . . . . . . . . . . . . . . . 67
BXR3K . . . . . . . . . . . . . . . . . . . . . . . . 67
BXR4S . . . . . . . . . . . . . . . . . . . . . . . . 67
BZ-2R-A2 . . . . . . . . . . . . . . . . . . . . 103
BZ-2RD-A2 . . . . . . . . . . . . . . . . . . . 103
BZ-2RDS-A2 . . . . . . . . . . . . . . . . . . 104
BZ-2RDS-A2S . . . . . . . . . . . . . . . . . 104
BZ-2RQ1-A2 . . . . . . . . . . . . . . . . . . 103
BZ-2RQ18-A2 . . . . . . . . . . . . . . . . . 104
BZ-2RQ181-A2 . . . . . . . . . . . . . . . . 104
BZ-2RW80-A2 . . . . . . . . . . . . . . . . . 104
BZ-2RW82-A2 . . . . . . . . . . . . . . . . . 104
BZ-2RW822 . . . . . . . . . . . . . . . . . . . 104
BZ-2RW822-A2 . . . . . . . . . . . . . . . . 104
BZ-2RW8225551-A2 . . . . . . . . . . . . 104
BZ-2RW826-A2 . . . . . . . . . . . . . . . . 104
BZ-2RW863-A2 . . . . . . . . . . . . . . . . 104
BZ-R . . . . . . . . . . . . . . . . . . . . . . . . 103
BZ-R-A2 . . . . . . . . . . . . . . . . . . . . . 103
BZ-R169 . . . . . . . . . . . . . . . . . . . . . 103
BZE6-2RN . . . . . . . . . . . . . . . . . . . . . 37
BZE6-2RN18 . . . . . . . . . . . . . . . . . . . 39
BZE6-2RN2 . . . . . . . . . . . . . . . . . . . . 38
BZE6-2RN234 . . . . . . . . . . . . . . . . . . 38
BZE6-2RN28 . . . . . . . . . . . . . . . . . . . 39
BZE6-2RN34 . . . . . . . . . . . . . . . . . . . 37
BZE6-2RN62 . . . . . . . . . . . . . . . . . . . 39
BZE6-2RN7 . . . . . . . . . . . . . . . . . . . . 37
BZE6-2RN72 . . . . . . . . . . . . . . . . . . . 37
BZE6-2RN80 . . . . . . . . . . . . . . . . . . . 37
BZE6-2RN81 . . . . . . . . . . . . . . . . . . . 38
BZE6-2RQ . . . . . . . . . . . . . . . . . . . . . 37
BZE6-2RQ2 . . . . . . . . . . . . . . . . . . . . 38
BZE6-2RQ62 . . . . . . . . . . . . . . . . . . . 39
BZE6-2RQ8 . . . . . . . . . . . . . . . . . . . . 37
BZE6-2RQ81 . . . . . . . . . . . . . . . . . . . 38
BZE6-2RQ9 . . . . . . . . . . . . . . . . . . . . 37
BZE6-RN2X1 . . . . . . . . . . . . . . . . . . . 40
BZE6-RN80X2 . . . . . . . . . . . . . . . . . . 40
BZE6-RNX1 . . . . . . . . . . . . . . . . . . . . 40
BZE6-RQ2X2 . . . . . . . . . . . . . . . . . . . 40
BZE6-RQ8X2 . . . . . . . . . . . . . . . . . . . 40
BZE6-RQX2 . . . . . . . . . . . . . . . . . . . . 40
BZE7-2RN-C . . . . . . . . . . . . . . . . . . . 41
BZE7-2RN-PG . . . . . . . . . . . . . . . . . . 41
BZE7-2RN18-PG . . . . . . . . . . . . . . . . 41
BZE7-2RN2-C . . . . . . . . . . . . . . . . . . 41
BZE7-2RN2-PG . . . . . . . . . . . . . . . . . 41
BZE7-2RQ-PG . . . . . . . . . . . . . . . . . . 41
BZE7-2RQ8-PG . . . . . . . . . . . . . . . . . 41
BZE7-2RQ81-PG . . . . . . . . . . . . . . . . 41
BZV6-2RN . . . . . . . . . . . . . . . . . . . . . 37
BZV6-2RN18 . . . . . . . . . . . . . . . . . . . 39
BZV6-2RN2 . . . . . . . . . . . . . . . . . . . . 38
BZV6-2RN4 . . . . . . . . . . . . . . . . . . . . 39
BZV6-2RN62 . . . . . . . . . . . . . . . . . . . 39
BZV6-2RN80 . . . . . . . . . . . . . . . . . . . 37
BZV6-2RQ . . . . . . . . . . . . . . . . . . . . . 37
BZV6-2RQ2 . . . . . . . . . . . . . . . . . . . . 38
BZV6-2RQ62 . . . . . . . . . . . . . . . . . . . 39
BZV6-2RQ8 . . . . . . . . . . . . . . . . . . . . 37
BZV6-2RQ81 . . . . . . . . . . . . . . . . . . . 38
C
CLSZC1 . . . . . . . . . . . . . . . . . . . . . . 102
CLSZC2 . . . . . . . . . . . . . . . . . . . . . . 102
CLSZC3 . . . . . . . . . . . . . . . . . . . . . . 102
CLSZC4 . . . . . . . . . . . . . . . . . . . . . . 102
CLSZC5 . . . . . . . . . . . . . . . . . . . . . . 102
CLSZC7 . . . . . . . . . . . . . . . . . . . . . . 102
CLSZTC . . . . . . . . . . . . . . . . . . . . . . 102
CPS-BRACKET . . . . . . . . . . . . . . . . 102
CPSLED120 . . . . . . . . . . . . . . . . . . . 102
CPSLED24 . . . . . . . . . . . . . . . . . . . . 102
CPSZ1S . . . . . . . . . . . . . . . . . . . . . . 102
CPSZK1 . . . . . . . . . . . . . . . . . . . . . . 102
CPSZTB . . . . . . . . . . . . . . . . . . . . . . 102
Custom Switches & Assemblies . . . . 173
Cargo Loading Systems . . . . . . . . 174
Flap Selectors . . . . . . . . . . . . . . . 174
Gear Selectors . . . . . . . . . . . . . . . 174
Harness Assemblies . . . . . . . . . . . 173
Operator Interface Products . . . . . 173
Rotary Switches . . . . . . . . . . . . . . 173
Switch Assemblies . . . . . . . . . . . . 173
D
DT-2R-A7 . . . . . . . . . . . . . . . . . . . . . 105
DTE6-2RN . . . . . . . . . . . . . . . . . . . . . 37
DTE6-2RN2 . . . . . . . . . . . . . . . . . . . . 38
DTE6-2RN80 . . . . . . . . . . . . . . . . . . . 37
DTE6-2RQ . . . . . . . . . . . . . . . . . . . . . 37
DTE6-2RQ81 . . . . . . . . . . . . . . . . . . . 38
DTE6-2RQ9 . . . . . . . . . . . . . . . . . . . . 37
DTE7-2RN-PG . . . . . . . . . . . . . . . . . . 41
DTF2-2RN-LH . . . . . . . . . . . . . . . . . . 42
DTF2-2RN-RH . . . . . . . . . . . . . . . . . . 42
DTF2-2RN2-LH . . . . . . . . . . . . . . . . . 43
DTF2-2RN2-RH . . . . . . . . . . . . . . . . . 43
DTF2-2RQ9-LH . . . . . . . . . . . . . . . . . 43
DTF2-2RQ9-RH . . . . . . . . . . . . . . . . . 43
DTF2-2RQN8-LH . . . . . . . . . . . . . . . . 43
DTF2-2RQN8-RH . . . . . . . . . . . . . . . . 43
DTV6-2RN . . . . . . . . . . . . . . . . . . . . . 37
DTV6-2RN2 . . . . . . . . . . . . . . . . . . . . 38
E
EVN2000A . . . . . . . . . . . . . . . . . . . . . 10
EVN2000B . . . . . . . . . . . . . . . . . . . . . 10
EVN2000C . . . . . . . . . . . . . . . . . . . . . 10
EVN2000D . . . . . . . . . . . . . . . . . . . . . 10
EX-AR . . . . . . . . . . . . . . . . . . . . . . . . 61
EX-AR141 . . . . . . . . . . . . . . . . . . . . . 61
EX-AR16 . . . . . . . . . . . . . . . . . . . . . . 61
EX-AR1613 . . . . . . . . . . . . . . . . . . . . 62
EX-AR182 . . . . . . . . . . . . . . . . . . . . . 61
EX-AR20 . . . . . . . . . . . . . . . . . . . . . . 60
EX-AR230 . . . . . . . . . . . . . . . . . . . . . 60
EX-AR30 . . . . . . . . . . . . . . . . . . . . . . 61
EX-AR400 . . . . . . . . . . . . . . . . . . . . . 61
EX-AR50 . . . . . . . . . . . . . . . . . . . . . . 63
EX-AR800 . . . . . . . . . . . . . . . . . . . . . 61
EX-AR830 . . . . . . . . . . . . . . . . . . . . . 61
EX-CR . . . . . . . . . . . . . . . . . . . . . . . . 62
EX-N15 . . . . . . . . . . . . . . . . . . . . . . . 63
EX-Q . . . . . . . . . . . . . . . . . . . . . . . . . 62
EX-Q400 . . . . . . . . . . . . . . . . . . . . . . 62
EX-Q62 . . . . . . . . . . . . . . . . . . . . . . . 62
EX-Q800 . . . . . . . . . . . . . . . . . . . . . . 62
EX-XR3 . . . . . . . . . . . . . . . . . . . . . . . 61
EXA-AR . . . . . . . . . . . . . . . . . . . . . . . 61
EXA-AR20 . . . . . . . . . . . . . . . . . . . . . 60
EXA-AR62 . . . . . . . . . . . . . . . . . . . . . 61
EXA-N . . . . . . . . . . . . . . . . . . . . . . . . 63
EXA-Q . . . . . . . . . . . . . . . . . . . . . . . . 62
EXD-AR-3 . . . . . . . . . . . . . . . . . . . . . 61
EXD-AR30-3 . . . . . . . . . . . . . . . . . . . 61
EXD-Q-3 . . . . . . . . . . . . . . . . . . . . . . 62
EXH-AR3 . . . . . . . . . . . . . . . . . . . . . . 61
EXH-AR33 . . . . . . . . . . . . . . . . . . . . . 61
INDEX
205
www.honeywell.com/sensing
EXH-AR7 . . . . . . . . . . . . . . . . . . . . . . 61
F
FR-01 . . . . . . . . . . . . . . . . . . . . . . . . . 160
FRL91-22CGA3-BB79 . . . . . . . . . . . . 160
FRL91-23CGG3-BB79 . . . . . . . . . . . . 160
FRL91-21CGG3-BB77 . . . . . . . . . . . . 160
FRL91-27CGG3-BB77 . . . . . . . . . . . . 160
FRN91-11BB . . . . . . . . . . . . . . . . . . . 159
FRN91-12BB . . . . . . . . . . . . . . . . . . . 159
FRN91-13BB . . . . . . . . . . . . . . . . . . . 159
FRN91-14BB . . . . . . . . . . . . . . . . . . . 159
FRN91-15BB . . . . . . . . . . . . . . . . . . . 159
FRN91-16BB . . . . . . . . . . . . . . . . . . . 159
FRN91-17BB . . . . . . . . . . . . . . . . . . . 159
FRN91-18BB . . . . . . . . . . . . . . . . . . . 159
FRN91-21BB . . . . . . . . . . . . . . . . . . . 159
FRN91-22BB . . . . . . . . . . . . . . . . . . . 159
FRN91-23BB . . . . . . . . . . . . . . . . . . . 159
FRN91-24BB . . . . . . . . . . . . . . . . . . . 159
FRN91-25BB . . . . . . . . . . . . . . . . . . . 159
FRN91-26BB . . . . . . . . . . . . . . . . . . . 159
FRN91-27BB . . . . . . . . . . . . . . . . . . . 159
FRN91-28BB . . . . . . . . . . . . . . . . . . . 159
G
GKBA10L7 . . . . . . . . . . . . . . . . . . . . . 88
GKBA14L6 . . . . . . . . . . . . . . . . . . . . . 88
GKBA14L7 . . . . . . . . . . . . . . . . . . . . . 88
GKBA16L6 . . . . . . . . . . . . . . . . . . . . . 88
GKBA16L7 . . . . . . . . . . . . . . . . . . . . . 88
GKBA1L7 . . . . . . . . . . . . . . . . . . . . . . 88
GKBA1L8-F11 . . . . . . . . . . . . . . . . . . 88
GKBA1LX . . . . . . . . . . . . . . . . . . . . . 88
GKBA2L6 . . . . . . . . . . . . . . . . . . . . . . 88
GKBA30LX . . . . . . . . . . . . . . . . . . . . 88
GKBA36LX . . . . . . . . . . . . . . . . . . . . 88
GKBA3L6 . . . . . . . . . . . . . . . . . . . . . . 88
GKBA3L7 . . . . . . . . . . . . . . . . . . . . . . 88
GKBA6LX . . . . . . . . . . . . . . . . . . . . . 88
GKBB14L6 . . . . . . . . . . . . . . . . . . . . . 88
GKBB3L7 . . . . . . . . . . . . . . . . . . . . . . 88
GKBB6L7 . . . . . . . . . . . . . . . . . . . . . . 88
GKBC14L7 . . . . . . . . . . . . . . . . . . . . . 88
GKBC1L6 . . . . . . . . . . . . . . . . . . . . . . 88
GKBC1L7 . . . . . . . . . . . . . . . . . . . . . . 88
GKBC1LX . . . . . . . . . . . . . . . . . . . . . 88
GKBC2LX . . . . . . . . . . . . . . . . . . . . . 88
GKBC30LX . . . . . . . . . . . . . . . . . . . . 88
GKBC36LX . . . . . . . . . . . . . . . . . . . . 88
GKBC6LX . . . . . . . . . . . . . . . . . . . . . 88
GKCA10L6 . . . . . . . . . . . . . . . . . . . . . 88
GKCA14L6 . . . . . . . . . . . . . . . . . . . . . 88
GKCA14L7 . . . . . . . . . . . . . . . . . . . . . 88
GKCA14L9 . . . . . . . . . . . . . . . . . . . . . 88
GKCA14M6 . . . . . . . . . . . . . . . . . . . . 88
GKCA14P6 . . . . . . . . . . . . . . . . . . . . 88
GKCA1L6 . . . . . . . . . . . . . . . . . . . . . . 88
GKCA1L7 . . . . . . . . . . . . . . . . . . . . . . 88
GKCA1LX . . . . . . . . . . . . . . . . . . . . . 88
GKCA1P7 . . . . . . . . . . . . . . . . . . . . . 88
GKCA30LX . . . . . . . . . . . . . . . . . . . . 88
GKCA36LX . . . . . . . . . . . . . . . . . . . . 88
GKCA6LX . . . . . . . . . . . . . . . . . . . . . 88
GKCC1LX . . . . . . . . . . . . . . . . . . . . . 88
GKCC30LX . . . . . . . . . . . . . . . . . . . . 88
GKCC36LX . . . . . . . . . . . . . . . . . . . . 88
GKCC6LX . . . . . . . . . . . . . . . . . . . . . 88
GKDA14L7 . . . . . . . . . . . . . . . . . . . . . 88
GKDA14P7 . . . . . . . . . . . . . . . . . . . . 88
GKEA1LX . . . . . . . . . . . . . . . . . . . . . . 94
GKEA3LX . . . . . . . . . . . . . . . . . . . . . . 94
GKEA6LX . . . . . . . . . . . . . . . . . . . . . . 94
GKEC1LX . . . . . . . . . . . . . . . . . . . . . . 94
GKEC3LX . . . . . . . . . . . . . . . . . . . . . . 94
GKEC6LX . . . . . . . . . . . . . . . . . . . . . . 94
GKLE36PXA2 . . . . . . . . . . . . . . . . . . 91
GKLE36PXA4 . . . . . . . . . . . . . . . . . . 91
GKLE36PXS2 . . . . . . . . . . . . . . . . . . 91
GKLE36PXS4 . . . . . . . . . . . . . . . . . . 91
GKLE3LXA2 . . . . . . . . . . . . . . . . . . . . 90
GKLE3PXA2 . . . . . . . . . . . . . . . . . . . 91
GKLE3PXA4 . . . . . . . . . . . . . . . . . . . 91
GKLE3PXS2 . . . . . . . . . . . . . . . . . . . 91
GKLE3PXS4 . . . . . . . . . . . . . . . . . . . 91
GKLE40LXA2 . . . . . . . . . . . . . . . . . . . 90
GKLE46LXA2 . . . . . . . . . . . . . . . . . . . 90
GKLG1PXA2 . . . . . . . . . . . . . . . . . . . 91
GKLG1PXA4 . . . . . . . . . . . . . . . . . . . 91
GKLG1PXS2 . . . . . . . . . . . . . . . . . . . 91
GKLG1PXS4 . . . . . . . . . . . . . . . . . . . 91
GKLG36PXA2 . . . . . . . . . . . . . . . . . . 91
GKLG36PXA4 . . . . . . . . . . . . . . . . . . 91
GKLG36PXS2 . . . . . . . . . . . . . . . . . . 91
GKLG36PXS4 . . . . . . . . . . . . . . . . . . 91
GKLG3PXS2 . . . . . . . . . . . . . . . . . . . 91
GKLG44PXB2 . . . . . . . . . . . . . . . . . . 91
GKM Series . . . . . . . . . . . . . . . . . . . . 82
GKMA17 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA19 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA23 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA26 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA27 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA29 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA33 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA36 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA37 . . . . . . . . . . . . . . . . . . . . . . 83
GKMA39 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB13 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB16 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB17 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB19 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB23 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB26 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB27 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB29 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB33 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB36 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB37 . . . . . . . . . . . . . . . . . . . . . . 83
GKMB39 . . . . . . . . . . . . . . . . . . . . . . 83
GKMC03 . . . . . . . . . . . . . . . . . . . . . . 83
GKMC06 . . . . . . . . . . . . . . . . . . . . . . 83
GKMC07 . . . . . . . . . . . . . . . . . . . . . . 83
GKMC09 . . . . . . . . . . . . . . . . . . . . . . 83
GKMD03 . . . . . . . . . . . . . . . . . . . . . . 83
GKMD07 . . . . . . . . . . . . . . . . . . . . . . 83
GKMD09 . . . . . . . . . . . . . . . . . . . . . . 83
GKMF03 . . . . . . . . . . . . . . . . . . . . . . . 83
GKMF06 . . . . . . . . . . . . . . . . . . . . . . . 83
GKMF07 . . . . . . . . . . . . . . . . . . . . . . . 83
GKMF09 . . . . . . . . . . . . . . . . . . . . . . . 83
GKNC12l . . . . . . . . . . . . . . . . . . . . . . 97
GKNC33L . . . . . . . . . . . . . . . . . . . . . . 97
GKNC4L . . . . . . . . . . . . . . . . . . . . . . . 97
GKNC6L . . . . . . . . . . . . . . . . . . . . . . . 97
GKRE36MXA2 . . . . . . . . . . . . . . . . . . 91
GKRE36MXA4 . . . . . . . . . . . . . . . . . . 91
GKRE36MXS2 . . . . . . . . . . . . . . . . . . 91
GKRE3MXA2 . . . . . . . . . . . . . . . . . . . 91
GKRE3MXA4 . . . . . . . . . . . . . . . . . . . 91
GKRE3MXS2 . . . . . . . . . . . . . . . . . . . 91
GKRE3MXS4 . . . . . . . . . . . . . . . . . . . 91
GKRE40LXA2 . . . . . . . . . . . . . . . . . . 90
GKRE46LXA2 . . . . . . . . . . . . . . . . . . 90
GKRG1MXA2 . . . . . . . . . . . . . . . . . . . 91
GKRG1MXA4 . . . . . . . . . . . . . . . . . . . 91
GKRG1MXS2 . . . . . . . . . . . . . . . . . . . 91
GKRG1MXS4 . . . . . . . . . . . . . . . . . . . 91
GKRG36MXA2 . . . . . . . . . . . . . . . . . . 91
GKRG36MXA4 . . . . . . . . . . . . . . . . . . 91
GKRG36MXS2 . . . . . . . . . . . . . . . . . . 91
GKRG36MXS4 . . . . . . . . . . . . . . . . . . 91
GKRG3MXA2 . . . . . . . . . . . . . . . . . . . 91
GKZ51M . . . . . . . . . . . . . . . . . . . . . . 83
GKZ52M . . . . . . . . . . . . . . . . . . . . . . 83
GKZ56 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ57 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ58 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ59 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ71 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ72 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ73 . . . . . . . . . . . . . . . . . . . . . . . . 92
GKZ74 . . . . . . . . . . . . . . . . . . . . . . . . 92
GLAA01A . . . . . . . . . . . . . . . . . . . . . . 15
GLAA01A1A . . . . . . . . . . . . . . . . . . . 15
GLAA01A1B . . . . . . . . . . . . . . . . . . . 15
GLAA01A2A . . . . . . . . . . . . . . . . . . . 15
GLAA01A2B . . . . . . . . . . . . . . . . . . . 15
INDEX
206 www.honeywell.com/sensing
GLAA01A4J . . . . . . . . . . . . . . . . . . . . 15
GLAA01B . . . . . . . . . . . . . . . . . . . . . . 15
GLAA01C . . . . . . . . . . . . . . . . . . . . . . 15
GLAA01D . . . . . . . . . . . . . . . . . . . . . . 15
GLAA01E7B . . . . . . . . . . . . . . . . . . . . 16
GLAA01E7D . . . . . . . . . . . . . . . . . . . . 16
GLAA01K8B . . . . . . . . . . . . . . . . . . . 16
GLAA01K8C . . . . . . . . . . . . . . . . . . . 16
GLAA20A . . . . . . . . . . . . . . . . . . . . . . 15
GLAA20A1A . . . . . . . . . . . . . . . . . . . 15
GLAA20A1B . . . . . . . . . . . . . . . . . . . 15
GLAA20A2A . . . . . . . . . . . . . . . . . . . 15
GLAA20A2B . . . . . . . . . . . . . . . . . . . 15
GLAA20A4J . . . . . . . . . . . . . . . . . . . . 15
GLAA20B . . . . . . . . . . . . . . . . . . . . . . 15
GLAA20C . . . . . . . . . . . . . . . . . . . . . . 15
GLAA20D . . . . . . . . . . . . . . . . . . . . . . 15
GLAA20K8C . . . . . . . . . . . . . . . . . . . 16
GLAB01A . . . . . . . . . . . . . . . . . . . . . . 15
GLAB01A1A . . . . . . . . . . . . . . . . . . . 15
GLAB01A1B . . . . . . . . . . . . . . . . . . . 15
GLAB01A2A . . . . . . . . . . . . . . . . . . . 15
GLAB01A2B . . . . . . . . . . . . . . . . . . . 15
GLAB01A4J . . . . . . . . . . . . . . . . . . . . 15
GLAB01B . . . . . . . . . . . . . . . . . . . . . . 15
GLAB01C . . . . . . . . . . . . . . . . . . . . . . 15
GLAB01D . . . . . . . . . . . . . . . . . . . . . . 15
GLAB01E7B . . . . . . . . . . . . . . . . . . . . 16
GLAB01K8B . . . . . . . . . . . . . . . . . . . 16
GLAB01K8C . . . . . . . . . . . . . . . . . . . 16
GLAB20A1A . . . . . . . . . . . . . . . . . . . 15
GLAB20A1B . . . . . . . . . . . . . . . . . . . 15
GLAB20A2A . . . . . . . . . . . . . . . . . . . 15
GLAB20A2B . . . . . . . . . . . . . . . . . . . 15
GLAB20A4J . . . . . . . . . . . . . . . . . . . . 15
GLAB20B . . . . . . . . . . . . . . . . . . . . . . 15
GLAB20C . . . . . . . . . . . . . . . . . . . . . . 15
GLAB20D . . . . . . . . . . . . . . . . . . . . . . 15
GLAB20E7B . . . . . . . . . . . . . . . . . . . . 16
GLAC01A1A . . . . . . . . . . . . . . . . . . . 15
GLAC01A1B . . . . . . . . . . . . . . . . . . . 15
GLAC01A2A . . . . . . . . . . . . . . . . . . . 15
GLAC01A2B . . . . . . . . . . . . . . . . . . . 15
GLAC01A4J . . . . . . . . . . . . . . . . . . . . 15
GLAC01B . . . . . . . . . . . . . . . . . . . . . . 15
GLAC01C . . . . . . . . . . . . . . . . . . . . . . 15
GLAC01D . . . . . . . . . . . . . . . . . . . . . . 15
GLAC01E7B . . . . . . . . . . . . . . . . . . . . 16
GLAC20A1A . . . . . . . . . . . . . . . . . . . 15
GLAC20A1B . . . . . . . . . . . . . . . . . . . 15
GLAC20A2B . . . . . . . . . . . . . . . . . . . 15
GLAC20B . . . . . . . . . . . . . . . . . . . . . . 15
GLAC20C . . . . . . . . . . . . . . . . . . . . . . 15
GLAC20D . . . . . . . . . . . . . . . . . . . . . . 15
GLAC20E7B . . . . . . . . . . . . . . . . . . . . 16
GLCA01A1A . . . . . . . . . . . . . . . . . . . 16
GLCA01A1B . . . . . . . . . . . . . . . . . . . 16
GLCA01A2A . . . . . . . . . . . . . . . . . . . 17
GLCA01A2B . . . . . . . . . . . . . . . . . . . 17
GLCA01A4J . . . . . . . . . . . . . . . . . . . . 17
GLCA01B . . . . . . . . . . . . . . . . . . . . . . 17
GLCA01C . . . . . . . . . . . . . . . . . . . . . . 17
GLCA01D . . . . . . . . . . . . . . . . . . . . . . 17
GLCA01E7B . . . . . . . . . . . . . . . . . . . . 17
GLCA01K8A . . . . . . . . . . . . . . . . . . . 17
GLCB01A1A . . . . . . . . . . . . . . . . . . . 16
GLCB01A1B . . . . . . . . . . . . . . . . . . . 16
GLCB01A2A . . . . . . . . . . . . . . . . . . . 17
GLCB01A2B . . . . . . . . . . . . . . . . . . . 17
GLCB01A4J . . . . . . . . . . . . . . . . . . . . 17
GLCB01B . . . . . . . . . . . . . . . . . . . . . . 17
GLCB01C . . . . . . . . . . . . . . . . . . . . . . 17
GLCB01D . . . . . . . . . . . . . . . . . . . . . . 17
GLCB01E7B . . . . . . . . . . . . . . . . . . . . 17
GLCB01K8A . . . . . . . . . . . . . . . . . . . 17
GLCC01A1B . . . . . . . . . . . . . . . . . . . 16
GLCC01A2B . . . . . . . . . . . . . . . . . . . 17
GLCC01B . . . . . . . . . . . . . . . . . . . . . . 17
GLCC01C . . . . . . . . . . . . . . . . . . . . . . 17
GLCC01D . . . . . . . . . . . . . . . . . . . . . . 17
GLCC01E7B . . . . . . . . . . . . . . . . . . . . 17
GLDA01A1A . . . . . . . . . . . . . . . . . . . 18
GLDA01A1B . . . . . . . . . . . . . . . . . . . 18
GLDA01A2A . . . . . . . . . . . . . . . . . . . 18
GLDA01A2B . . . . . . . . . . . . . . . . . . . 18
GLDA01A4J . . . . . . . . . . . . . . . . . . . . 18
GLDA01B . . . . . . . . . . . . . . . . . . . . . . 18
GLDA01C . . . . . . . . . . . . . . . . . . . . . . 18
GLDA01D . . . . . . . . . . . . . . . . . . . . . . 18
GLDA01E7B . . . . . . . . . . . . . . . . . . . . 18
GLDB01A1A . . . . . . . . . . . . . . . . . . . 18
GLDB01A1B . . . . . . . . . . . . . . . . . . . 18
GLDB01A2A . . . . . . . . . . . . . . . . . . . 18
GLDB01A2B . . . . . . . . . . . . . . . . . . . 18
GLDB01A4J . . . . . . . . . . . . . . . . . . . . 18
GLDB01B . . . . . . . . . . . . . . . . . . . . . . 18
GLDB01C . . . . . . . . . . . . . . . . . . . . . . 18
GLDB01D . . . . . . . . . . . . . . . . . . . . . . 18
GLDB01E7B . . . . . . . . . . . . . . . . . . . . 18
GLDC01A1B . . . . . . . . . . . . . . . . . . . 18
GLDC01A2B . . . . . . . . . . . . . . . . . . . 18
GLDC01B . . . . . . . . . . . . . . . . . . . . . . 18
GLDC01C . . . . . . . . . . . . . . . . . . . . . . 18
GLDC01D . . . . . . . . . . . . . . . . . . . . . . 18
GLDC01E7B . . . . . . . . . . . . . . . . . . . . 18
GLEA01A1A . . . . . . . . . . . . . . . . . . . . 18
GLEA01A1B . . . . . . . . . . . . . . . . . . . . 18
GLEA01A2A . . . . . . . . . . . . . . . . . . . . 19
GLEA01A2B . . . . . . . . . . . . . . . . . . . . 19
GLEA01A5A . . . . . . . . . . . . . . . . . . . . 19
GLEA01B . . . . . . . . . . . . . . . . . . . . . . 19
GLEA01C . . . . . . . . . . . . . . . . . . . . . . 19
GLEA01D . . . . . . . . . . . . . . . . . . . . . . 19
GLEA01E7B . . . . . . . . . . . . . . . . . . . . 19
GLEA24A1B . . . . . . . . . . . . . . . . . . . . 18
GLEA24A2A . . . . . . . . . . . . . . . . . . . . 19
GLEA24B . . . . . . . . . . . . . . . . . . . . . . 19
GLEA24C . . . . . . . . . . . . . . . . . . . . . . 19
GLEA24D . . . . . . . . . . . . . . . . . . . . . . 19
GLEA24E7B . . . . . . . . . . . . . . . . . . . . 19
GLEB01A1A . . . . . . . . . . . . . . . . . . . . 18
GLEB01A1B . . . . . . . . . . . . . . . . . . . . 18
GLEB01A2A . . . . . . . . . . . . . . . . . . . . 19
GLEB01A2B . . . . . . . . . . . . . . . . . . . . 19
GLEB01A4J . . . . . . . . . . . . . . . . . . . . 19
GLEB01A5A . . . . . . . . . . . . . . . . . . . . 19
GLEB01B . . . . . . . . . . . . . . . . . . . . . . 19
GLEB01C . . . . . . . . . . . . . . . . . . . . . . 19
GLEB01D . . . . . . . . . . . . . . . . . . . . . . 19
GLEB01E7B . . . . . . . . . . . . . . . . . . . . 19
GLEB24A1A . . . . . . . . . . . . . . . . . . . . 18
GLEB24A1B . . . . . . . . . . . . . . . . . . . . 18
GLEB24A2B . . . . . . . . . . . . . . . . . . . . 19
GLEB24A4J . . . . . . . . . . . . . . . . . . . . 19
GLEB24B . . . . . . . . . . . . . . . . . . . . . . 19
GLEB24C . . . . . . . . . . . . . . . . . . . . . . 19
GLEB24D . . . . . . . . . . . . . . . . . . . . . . 19
GLEB24E7B . . . . . . . . . . . . . . . . . . . . 19
GLEC01A1B . . . . . . . . . . . . . . . . . . . . 18
GLEC01D . . . . . . . . . . . . . . . . . . . . . . 19
GLEC24C . . . . . . . . . . . . . . . . . . . . . . 19
GLEC24D . . . . . . . . . . . . . . . . . . . . . . 19
GLL EN 50047 . . . . . . . . . . . . . . . . . . 20
GLZ51A . . . . . . . . . . . . . . . . . . . . . . . 72
GLZ51B . . . . . . . . . . . . . . . . . . . . . . . 72
GLZ52A . . . . . . . . . . . . . . . . . . . . . . . 72
GLZ52B . . . . . . . . . . . . . . . . . . . . . . . 72
GLZ54J . . . . . . . . . . . . . . . . . . . . . . . 72
GLZ55B . . . . . . . . . . . . . . . . . . . . . . . 72
GSCA01S1 . . . . . . . . . . . . . . . . . . . . 85
GSCA01S2 . . . . . . . . . . . . . . . . . . . . 85
GSCA01S3 . . . . . . . . . . . . . . . . . . . . 85
GSCA03S1 . . . . . . . . . . . . . . . . . . . . 85
GSCA03S2 . . . . . . . . . . . . . . . . . . . . 85
GSCA03S3 . . . . . . . . . . . . . . . . . . . . 85
GSCA06S1 . . . . . . . . . . . . . . . . . . . . 85
GSCA06S2 . . . . . . . . . . . . . . . . . . . . 85
GSCA06S3 . . . . . . . . . . . . . . . . . . . . 85
GSCB36S2 . . . . . . . . . . . . . . . . . . . . 85
GSCB36S3 . . . . . . . . . . . . . . . . . . . . 85
GSCC36S1 . . . . . . . . . . . . . . . . . . . . 85
GSDA03S1 . . . . . . . . . . . . . . . . . . . . 85
GSDA03S2 . . . . . . . . . . . . . . . . . . . . 85
GSDA03S3 . . . . . . . . . . . . . . . . . . . . 85
GSDA06S1 . . . . . . . . . . . . . . . . . . . . 85
GSDA06S2 . . . . . . . . . . . . . . . . . . . . 85
GSDA06S3 . . . . . . . . . . . . . . . . . . . . 85
GSDB03S1 . . . . . . . . . . . . . . . . . . . . 85
INDEX
207
www.honeywell.com/sensing
GSDB03S2 . . . . . . . . . . . . . . . . . . . . 85
GSDB03S3 . . . . . . . . . . . . . . . . . . . . 85
GSDB06S1 . . . . . . . . . . . . . . . . . . . . 85
GSDB06S2 . . . . . . . . . . . . . . . . . . . . 85
GSDB06S3 . . . . . . . . . . . . . . . . . . . . 85
GSDC01S1 . . . . . . . . . . . . . . . . . . . . 85
GSDC01S2 . . . . . . . . . . . . . . . . . . . . 85
GSDC01S3 . . . . . . . . . . . . . . . . . . . . 85
GSEA44S1 . . . . . . . . . . . . . . . . . . . . . 86
GSEA44S2 . . . . . . . . . . . . . . . . . . . . . 86
GSEA44S3 . . . . . . . . . . . . . . . . . . . . . 86
GSEA46S1 . . . . . . . . . . . . . . . . . . . . . 86
GSEC41S1 . . . . . . . . . . . . . . . . . . . . . 86
GSS Series . . . . . . . . . . . . . . . . . . . . 84
GXE Series . . . . . . . . . . . . . . . . . . . . . 59
GXE51A1B . . . . . . . . . . . . . . . . . . . . . 59
GXE51B . . . . . . . . . . . . . . . . . . . . . . . 59
GXE51C . . . . . . . . . . . . . . . . . . . . . . . 59
H
HRSR-01 . . . . . . . . . . . . . . . . . . . . . 162
J
JE-1 . . . . . . . . . . . . . . . . . . . . . . . . . 123
JE-4 . . . . . . . . . . . . . . . . . . . . . . . . . 123
JE-5 . . . . . . . . . . . . . . . . . . . . . . . . . 123
JM-1 . . . . . . . . . . . . . . . . . . . . . . . . 125
JM-5 . . . . . . . . . . . . . . . . . . . . . . . . 125
JS-151 . . . . . . . . . . . . . . . . . . . . . . . 127
JS-254 . . . . . . . . . . . . . . . . . . . . . . . 127
L
Levers . . . . . . . . . . . . . . . . . . . . . . . . 71
LS2A4K . . . . . . . . . . . . . . . . . . . . . . . 55
LS2A4L . . . . . . . . . . . . . . . . . . . . . . . 55
LS2D4K . . . . . . . . . . . . . . . . . . . . . . . 55
LS2D4L . . . . . . . . . . . . . . . . . . . . . . . 55
LS2E4K . . . . . . . . . . . . . . . . . . . . . . . 55
LS2E4L . . . . . . . . . . . . . . . . . . . . . . . 55
LS2F4K . . . . . . . . . . . . . . . . . . . . . . . 55
LS2F4L . . . . . . . . . . . . . . . . . . . . . . . 55
LS2H4K . . . . . . . . . . . . . . . . . . . . . . . 55
LS2H4L . . . . . . . . . . . . . . . . . . . . . . . 55
LS2M4N . . . . . . . . . . . . . . . . . . . . . . 55
LS2Z51A . . . . . . . . . . . . . . . . . . . . . . 73
LS2Z51B . . . . . . . . . . . . . . . . . . . . . . 73
LS2Z52A . . . . . . . . . . . . . . . . . . . . . . 73
LS2Z52B . . . . . . . . . . . . . . . . . . . . . . 73
LS2Z54N . . . . . . . . . . . . . . . . . . . . . . 73
LS4A1A . . . . . . . . . . . . . . . . . . . . . . . 49
LS4A2B . . . . . . . . . . . . . . . . . . . . . . . 49
LS4A3K . . . . . . . . . . . . . . . . . . . . . . . 49
LS4M2D . . . . . . . . . . . . . . . . . . . . . . 49
LSA1A . . . . . . . . . . . . . . . . . . . . . . . . 49
LSA1E . . . . . . . . . . . . . . . . . . . . . . . . 49
LSA2B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSA3K . . . . . . . . . . . . . . . . . . . . . . . . 49
LSA4L . . . . . . . . . . . . . . . . . . . . . . . . 49
LSA6B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSA6S . . . . . . . . . . . . . . . . . . . . . . . . 49
LSC1A . . . . . . . . . . . . . . . . . . . . . . . . 50
LSC1E . . . . . . . . . . . . . . . . . . . . . . . . 50
LSC3K . . . . . . . . . . . . . . . . . . . . . . . . 50
LSC6B . . . . . . . . . . . . . . . . . . . . . . . . 50
LSC6S . . . . . . . . . . . . . . . . . . . . . . . . 50
LSC7L . . . . . . . . . . . . . . . . . . . . . . . . 50
LSD1A . . . . . . . . . . . . . . . . . . . . . . . . 50
LSD1E . . . . . . . . . . . . . . . . . . . . . . . . 50
LSD3K . . . . . . . . . . . . . . . . . . . . . . . . 50
LSD6B . . . . . . . . . . . . . . . . . . . . . . . . 50
LSD6S . . . . . . . . . . . . . . . . . . . . . . . . 50
LSD7L . . . . . . . . . . . . . . . . . . . . . . . . 50
LSE1A . . . . . . . . . . . . . . . . . . . . . . . . 51
LSE1E . . . . . . . . . . . . . . . . . . . . . . . . 51
LSE3K . . . . . . . . . . . . . . . . . . . . . . . . 51
LSE6B . . . . . . . . . . . . . . . . . . . . . . . . 51
LSE6S . . . . . . . . . . . . . . . . . . . . . . . . 51
LSE7L . . . . . . . . . . . . . . . . . . . . . . . . 51
LSF1A . . . . . . . . . . . . . . . . . . . . . . . . 51
LSF1E . . . . . . . . . . . . . . . . . . . . . . . . 51
LSF3K . . . . . . . . . . . . . . . . . . . . . . . . 51
LSF6B . . . . . . . . . . . . . . . . . . . . . . . . 51
LSF6S . . . . . . . . . . . . . . . . . . . . . . . . 51
LSF7L . . . . . . . . . . . . . . . . . . . . . . . . 51
LSG1A . . . . . . . . . . . . . . . . . . . . . . . . 51
LSG1E . . . . . . . . . . . . . . . . . . . . . . . . 51
LSG3K . . . . . . . . . . . . . . . . . . . . . . . . 51
LSG6B . . . . . . . . . . . . . . . . . . . . . . . . 51
LSG6S . . . . . . . . . . . . . . . . . . . . . . . . 51
LSG7L . . . . . . . . . . . . . . . . . . . . . . . . 51
LSH1A . . . . . . . . . . . . . . . . . . . . . . . . 49
LSH1E . . . . . . . . . . . . . . . . . . . . . . . . 49
LSH2B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSH3K . . . . . . . . . . . . . . . . . . . . . . . . 49
LSH4L . . . . . . . . . . . . . . . . . . . . . . . . 49
LSH6B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSH6S . . . . . . . . . . . . . . . . . . . . . . . . 49
LSJ1A-7A . . . . . . . . . . . . . . . . . . . . . 52
LSJ1A-7M . . . . . . . . . . . . . . . . . . . . . 52
LSJ1A-7N . . . . . . . . . . . . . . . . . . . . . 52
LSJ3K-7A . . . . . . . . . . . . . . . . . . . . . 52
LSJ3K-7M . . . . . . . . . . . . . . . . . . . . . 52
LSJ3K-7N . . . . . . . . . . . . . . . . . . . . . 52
LSJ6B-7A . . . . . . . . . . . . . . . . . . . . . 52
LSJ6B-7M . . . . . . . . . . . . . . . . . . . . . 52
LSJ6B-7N . . . . . . . . . . . . . . . . . . . . . 52
LSJ7L-7A . . . . . . . . . . . . . . . . . . . . . 52
LSJ7L-7M . . . . . . . . . . . . . . . . . . . . . 52
LSJ7L-7N . . . . . . . . . . . . . . . . . . . . . 52
LSK1A-8A . . . . . . . . . . . . . . . . . . . . . 52
LSK1A-8C . . . . . . . . . . . . . . . . . . . . . 52
LSK3K-8A . . . . . . . . . . . . . . . . . . . . . 52
LSK3K-8C . . . . . . . . . . . . . . . . . . . . . 52
LSK6B-8A . . . . . . . . . . . . . . . . . . . . . 52
LSK6B-8C . . . . . . . . . . . . . . . . . . . . . 52
LSK7L-8A . . . . . . . . . . . . . . . . . . . . . 52
LSK7L-8C . . . . . . . . . . . . . . . . . . . . . 52
LSL2C . . . . . . . . . . . . . . . . . . . . . . . . 49
LSL4M . . . . . . . . . . . . . . . . . . . . . . . . 49
LSL6C . . . . . . . . . . . . . . . . . . . . . . . . 49
LSL7M . . . . . . . . . . . . . . . . . . . . . . . . 49
LSM2D . . . . . . . . . . . . . . . . . . . . . . . 49
LSM4N . . . . . . . . . . . . . . . . . . . . . . . 49
LSM6D . . . . . . . . . . . . . . . . . . . . . . . 49
LSM7N . . . . . . . . . . . . . . . . . . . . . . . 49
LSN1A . . . . . . . . . . . . . . . . . . . . . . . . 50
LSN3K . . . . . . . . . . . . . . . . . . . . . . . . 50
LSN6B . . . . . . . . . . . . . . . . . . . . . . . . 50
LSN7L . . . . . . . . . . . . . . . . . . . . . . . . 50
LSP1A . . . . . . . . . . . . . . . . . . . . . . . . 49
LSP1E . . . . . . . . . . . . . . . . . . . . . . . . 49
LSP2B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSP3K . . . . . . . . . . . . . . . . . . . . . . . . 49
LSP4L . . . . . . . . . . . . . . . . . . . . . . . . 49
LSP6B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSP6S . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR1A . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR1E . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR2B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR3K . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR4L . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR6B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSR6S . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU1A . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU1E . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU2B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU3K . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU4L . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU6B . . . . . . . . . . . . . . . . . . . . . . . . 49
LSU6S . . . . . . . . . . . . . . . . . . . . . . . . 49
LSV1A . . . . . . . . . . . . . . . . . . . . . . . . 50
LSV1E . . . . . . . . . . . . . . . . . . . . . . . . 50
LSV3K . . . . . . . . . . . . . . . . . . . . . . . . 50
LSV6B . . . . . . . . . . . . . . . . . . . . . . . . 50
LSV6S . . . . . . . . . . . . . . . . . . . . . . . . 50
LSV7L . . . . . . . . . . . . . . . . . . . . . . . . 50
LSW1A . . . . . . . . . . . . . . . . . . . . . . . 51
LSW1E . . . . . . . . . . . . . . . . . . . . . . . 51
LSW3K . . . . . . . . . . . . . . . . . . . . . . . 51
LSW6B . . . . . . . . . . . . . . . . . . . . . . . 51
LSW6S . . . . . . . . . . . . . . . . . . . . . . . 51
LSW7L . . . . . . . . . . . . . . . . . . . . . . . 51
LSX4A3K . . . . . . . . . . . . . . . . . . . . . . 67
LSX4A4L . . . . . . . . . . . . . . . . . . . . . . 67
LSX4C3K . . . . . . . . . . . . . . . . . . . . . . 68
LSX4D3K . . . . . . . . . . . . . . . . . . . . . . 68
LSX4M4N . . . . . . . . . . . . . . . . . . . . . 67
LSXA3E . . . . . . . . . . . . . . . . . . . . . . . 67
INDEX
208 www.honeywell.com/sensing
LSXA3K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXA4K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXA4L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXA7L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXB3K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXB4L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXC3K . . . . . . . . . . . . . . . . . . . . . . . 68
LSXC4L . . . . . . . . . . . . . . . . . . . . . . . 68
LSXD3K . . . . . . . . . . . . . . . . . . . . . . . 68
LSXD4L . . . . . . . . . . . . . . . . . . . . . . . 68
LSXE3K . . . . . . . . . . . . . . . . . . . . . . . 69
LSXE4L . . . . . . . . . . . . . . . . . . . . . . . 69
LSXF3K . . . . . . . . . . . . . . . . . . . . . . . 69
LSXH3K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXH4L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXJ3K-7A . . . . . . . . . . . . . . . . . . . . 69
LSXJ4L-7A . . . . . . . . . . . . . . . . . . . . 69
LSXK3K-8A . . . . . . . . . . . . . . . . . . . . 69
LSXM4N . . . . . . . . . . . . . . . . . . . . . . 67
LSXN3K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXN4L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXN7L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXP3K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXR3K . . . . . . . . . . . . . . . . . . . . . . . 67
LSXR4L . . . . . . . . . . . . . . . . . . . . . . . 67
LSXV3K . . . . . . . . . . . . . . . . . . . . . . . 68
LSY*C3KP-**FP . . . . . . . . . . . . . . . . 54
LSY*C3KQ-**FP . . . . . . . . . . . . . . . . 54
LSY*C4LX-**FP . . . . . . . . . . . . . . . . 54
LSY*C7LR-**FP . . . . . . . . . . . . . . . . 54
LSYAC3KP-FP . . . . . . . . . . . . . . . . . . 53
LSYAC3KQ-FP . . . . . . . . . . . . . . . . . . 53
LSYAC4LX-FP . . . . . . . . . . . . . . . . . . 53
LSYAC7LR-FP . . . . . . . . . . . . . . . . . . 53
LSYCC3KP-FP . . . . . . . . . . . . . . . . . . 54
LSYCC3KQ-FP . . . . . . . . . . . . . . . . . . 54
LSYCC4LX-FP . . . . . . . . . . . . . . . . . . 54
LSYCC7LR-FP . . . . . . . . . . . . . . . . . . 54
LSYDC3KP-FP . . . . . . . . . . . . . . . . . . 54
LSYDC3KQ-FP . . . . . . . . . . . . . . . . . . 54
LSYDC4LX-FP . . . . . . . . . . . . . . . . . . 54
LSYDC7LR-FP . . . . . . . . . . . . . . . . . . 54
LSYEC3KP-FP . . . . . . . . . . . . . . . . . . 54
LSYEC3KQ-FP . . . . . . . . . . . . . . . . . . 54
LSYEC4LX-FP . . . . . . . . . . . . . . . . . . 54
LSYEC7LR-FP . . . . . . . . . . . . . . . . . . 54
LSYLC4MX-FP . . . . . . . . . . . . . . . . . 54
LSYLC7MR-FP . . . . . . . . . . . . . . . . . 54
LSYMC4NX-FP . . . . . . . . . . . . . . . . . 54
LSYMC7NR-FP . . . . . . . . . . . . . . . . . 54
LSYPC3KP-FP . . . . . . . . . . . . . . . . . . 53
LSYPC3KQ-FP . . . . . . . . . . . . . . . . . . 53
LSYPC4LX-FP . . . . . . . . . . . . . . . . . . 53
LSYPC7LR-FP . . . . . . . . . . . . . . . . . . 53
LSYUC3KP-FP . . . . . . . . . . . . . . . . . . 53
LSYUC3KQ-FP . . . . . . . . . . . . . . . . . . 53
LSZ51 . . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ51A . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ51B . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ51C . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ51D . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ51W . . . . . . . . . . . . . . . . . . . . . . 73
LSZ51Y . . . . . . . . . . . . . . . . . . . . . . . 73
LSZ52 . . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52A . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52B . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52C . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52D . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52J . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52K . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52M . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52N . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ52W . . . . . . . . . . . . . . . . . . . . . . 73
LSZ52Y . . . . . . . . . . . . . . . . . . . . . . . 73
LSZ53A . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ53B . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ53D . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ53E . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ53P . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ53S . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ53U . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ54 . . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ54M . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ54N . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ54R . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ54V . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ55 . . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ55A . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ55B . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ55C . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ55D . . . . . . . . . . . . . . . . . . . . . . . 72
LSZ55W . . . . . . . . . . . . . . . . . . . . . . 73
LSZ55Y . . . . . . . . . . . . . . . . . . . . . . . 73
LSZ61 . . . . . . . . . . . . . . . . . . . . . . . . 73
LSZ67AA . . . . . . . . . . . . . . . . . . . . . . 73
LSZ68 . . . . . . . . . . . . . . . . . . . . . . . . 72
M
MR93-12BBN . . . . . . . . . . . . . . . . . . 163
MR93-121BK . . . . . . . . . . . . . . . . . . . 163
MR93-122B3 . . . . . . . . . . . . . . . . . . . 163
MR93-122BJ . . . . . . . . . . . . . . . . . . . 163
MR93-124B3 . . . . . . . . . . . . . . . . . . . 163
MR93-22BBN . . . . . . . . . . . . . . . . . . 163
MR93-221B4 . . . . . . . . . . . . . . . . . . . 163
MR93-222B3 . . . . . . . . . . . . . . . . . . . 163
MR93-224B3 . . . . . . . . . . . . . . . . . . . 163
MRS93-11BB . . . . . . . . . . . . . . . . . . 164
MRS93-12BB . . . . . . . . . . . . . . . . . . 164
MRS93-13BB . . . . . . . . . . . . . . . . . . 164
MRS93-14BB . . . . . . . . . . . . . . . . . . 164
MRS93-15BB . . . . . . . . . . . . . . . . . . 164
MRS93-16BB . . . . . . . . . . . . . . . . . . 164
MRS93-17BB . . . . . . . . . . . . . . . . . . 164
MRS93-18BB . . . . . . . . . . . . . . . . . . 164
P
Precision Aerospace . . . . . . . . . . . . . 195
S
SL1-A . . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-AK . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-B . . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-BK . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-D . . . . . . . . . . . . . . . . . . . . . . . . 22
SL1-DK . . . . . . . . . . . . . . . . . . . . . . . 22
SL1-E . . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-EK . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-H . . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-HK . . . . . . . . . . . . . . . . . . . . . . . 21
SL1-K . . . . . . . . . . . . . . . . . . . . . . . . 22
SL1-KK . . . . . . . . . . . . . . . . . . . . . . . 22
SL1-P . . . . . . . . . . . . . . . . . . . . . . . . 22
SL1-PK . . . . . . . . . . . . . . . . . . . . . . . 22
SR-01 . . . . . . . . . . . . . . . . . . . . . . . . 162
SRL91-22ARN3-BB9N . . . . . . . . . . . . 162
SRL91-21URR3-BB99 . . . . . . . . . . . . 162
SRL91-21UGG3-BB99 . . . . . . . . . . . . 162
SRL91-22UGA3-BB99 . . . . . . . . . . . . 162
SRL91-22UGG3-BB99 . . . . . . . . . . . . 162
SRL91-23UGG3-BB99 . . . . . . . . . . . . 162
SRL91-23URR3-BB99 . . . . . . . . . . . . 162
SRL91-27URR3-BB99 . . . . . . . . . . . . 162
SRN91-11BB . . . . . . . . . . . . . . . . . . . 161
SRN91-12BB . . . . . . . . . . . . . . . . . . . 161
SRN91-13BB . . . . . . . . . . . . . . . . . . . 161
SRN91-14BB . . . . . . . . . . . . . . . . . . . 161
SRN91-15BB . . . . . . . . . . . . . . . . . . . 161
SRN91-16BB . . . . . . . . . . . . . . . . . . . 161
SRN91-17BB . . . . . . . . . . . . . . . . . . . 161
SRN91-18BB . . . . . . . . . . . . . . . . . . . 161
SRN91-21BB . . . . . . . . . . . . . . . . . . . 161
SRN91-22BB . . . . . . . . . . . . . . . . . . . 161
SRN91-23BB . . . . . . . . . . . . . . . . . . . 161
SRN91-24BB . . . . . . . . . . . . . . . . . . . 161
SRN91-25BB . . . . . . . . . . . . . . . . . . . 161
SRN91-26BB . . . . . . . . . . . . . . . . . . . 161
SRN91-27BB . . . . . . . . . . . . . . . . . . . 161
SRN91-28BB . . . . . . . . . . . . . . . . . . . 161
SZL-VL-A . . . . . . . . . . . . . . . . . . . . . 11
SZL-VL-B . . . . . . . . . . . . . . . . . . . . . 11
SZL-VL-C . . . . . . . . . . . . . . . . . . . . . 12
SZL-VL-D . . . . . . . . . . . . . . . . . . . . . 12
SZL-VL-E . . . . . . . . . . . . . . . . . . . . . . 13
SZL-VL-F . . . . . . . . . . . . . . . . . . . . . . 13
SZL-VL-G . . . . . . . . . . . . . . . . . . . . . 13
SZL-VL-H . . . . . . . . . . . . . . . . . . . . . 12
SZR-LY2-1-AC110-120V . . . . . . . . . . 76
INDEX
209
www.honeywell.com/sensing
SZR-LY2-1-AC220V . . . . . . . . . . . . . 76
SZR-LY2-1-DC12V . . . . . . . . . . . . . . 76
SZR-LY2-1-DC24V . . . . . . . . . . . . . . 76
SZR-LY2-1P-AC110-120V . . . . . . . . . 76
SZR-LY2-1P-DC24V . . . . . . . . . . . . . 76
SZR-LY2-D1-DC24V . . . . . . . . . . . . . 76
SZR-LY2-N1-AC110-120V . . . . . . . . . 76
SZR-LY2-N1-AC220V . . . . . . . . . . . . 76
SZR-LY2-N1-DC12V . . . . . . . . . . . . . 76
SZR-LY2-N1-DC24V . . . . . . . . . . . . . 76
SZR-LY2-X1-DC24V . . . . . . . . . . . . . 76
SZR-LY4-1-AC110-120V . . . . . . . . . . 77
SZR-LY4-1-AC220V . . . . . . . . . . . . . 77
SZR-LY4-1-DC12V . . . . . . . . . . . . . . 77
SZR-LY4-1-DC24V . . . . . . . . . . . . . . 77
SZR-LY4-1P-AC110-120V . . . . . . . . . 77
SZR-LY4-1P-AC220V-240V . . . . . . . 77
SZR-LY4-1P-DC24V . . . . . . . . . . . . . 77
SZR-LY4-D1-DC24V . . . . . . . . . . . . . 77
SZR-LY4-N1-AC110-120V . . . . . . . . . 77
SZR-LY4-N1-AC220V . . . . . . . . . . . . 77
SZR-LY4-N1-DC12V . . . . . . . . . . . . . 77
SZR-LY4-N1-DC24V . . . . . . . . . . . . . 77
SZR-LY4-X1-DC24V . . . . . . . . . . . . . 77
SZR-MY2-1-AC110-120V . . . . . . . . . 74
SZR-MY2-1-AC220V . . . . . . . . . . . . . 74
SZR-MY2-1-DC12V . . . . . . . . . . . . . . 74
SZR-MY2-1-DC24V . . . . . . . . . . . . . . 74
SZR-MY2-1P-AC110-120V . . . . . . . . 74
SZR-MY2-1P-AC220V-240V . . . . . . . 74
SZR-MY2-1P-DC24V . . . . . . . . . . . . . 74
SZR-MY2-D1-DC24V . . . . . . . . . . . . . 74
SZR-MY2-N1-AC110-120V . . . . . . . . 74
SZR-MY2-N1-AC220V . . . . . . . . . . . . 74
SZR-MY2-N1-DC12V . . . . . . . . . . . . . 74
SZR-MY2-N1-DC24V . . . . . . . . . . . . . 74
SZR-MY2-X1-DC24V . . . . . . . . . . . . . 74
SZR-MY4-1-AC110-120V . . . . . . . . . 75
SZR-MY4-1-AC220V . . . . . . . . . . . . . 75
SZR-MY4-1-DC12V . . . . . . . . . . . . . . 75
SZR-MY4-1-DC24V . . . . . . . . . . . . . . 75
SZR-MY4-1P-AC110-120V . . . . . . . . 75
SZR-MY4-1P-AC220V-240V . . . . . . . 75
SZR-MY4-1P-DC24V . . . . . . . . . . . . . 75
SZR-MY4-D1-DC24V . . . . . . . . . . . . . 75
SZR-MY4-N1-AC110-120V . . . . . . . . 75
SZR-MY4-N1-AC220V . . . . . . . . . . . . 75
SZR-MY4-N1-DC12V . . . . . . . . . . . . . 75
SZR-MY4-N1-DC24V . . . . . . . . . . . . . 75
SZR-MY4-X1-DC24V . . . . . . . . . . . . . 75
SZX-SLF-08N . . . . . . . . . . . . . . . . . . 78
SZX-SLF-14 . . . . . . . . . . . . . . . . . . . . 78
SZX-SMF-08N . . . . . . . . . . . . . . . . . . 78
SZX-SMF-14N . . . . . . . . . . . . . . . . . . 78
V
V7-1A17D8 . . . . . . . . . . . . . . . . . . . 110
V7-1A17D8-022 . . . . . . . . . . . . . . . 111
V7-1A17P02 . . . . . . . . . . . . . . . . . . 110
V7-1B10E9-207 . . . . . . . . . . . . . . . . 111
V7-1B17D8 . . . . . . . . . . . . . . . . . . . 110
V7-1B17D8-048 . . . . . . . . . . . . . . . 111
V7-1B17D8-263 . . . . . . . . . . . . . . . 111
V7-1B19D8-022 . . . . . . . . . . . . . . . 111
V7-1B19E9 . . . . . . . . . . . . . . . . . . . 110
V7-1C17D8 . . . . . . . . . . . . . . . . . . . 110
V7-1C17D8-002 . . . . . . . . . . . . . . . 111
V7-1C17D8-022 . . . . . . . . . . . . . . . 111
V7-1C17D8-048 . . . . . . . . . . . . . . . 111
V7-1C17D8-201 . . . . . . . . . . . . . . . 111
V7-1C17D8-207 . . . . . . . . . . . . . . . 111
V7-1C17D8-263 . . . . . . . . . . . . . . . 111
V7-1C17E9 . . . . . . . . . . . . . . . . . . . 110
V7-1C17E9-002 . . . . . . . . . . . . . . . . 111
V7-1C17E9-201 . . . . . . . . . . . . . . . . 111
V7-1C17E9-207 . . . . . . . . . . . . . . . . 111
V7-1D10D8 . . . . . . . . . . . . . . . . . . . 110
V7-1S17D8 . . . . . . . . . . . . . . . . . . . 110
V7-1S17D8-022 . . . . . . . . . . . . . . . 111
V7-1S17D8-201 . . . . . . . . . . . . . . . 111
V7-1S17D8-207 . . . . . . . . . . . . . . . 111
V7-1S17D8-263 . . . . . . . . . . . . . . . 111
V7-1V19E9 . . . . . . . . . . . . . . . . . . . 110
V7-1V19E9-048 . . . . . . . . . . . . . . . . 111
V7-1V19E9-207 . . . . . . . . . . . . . . . . 111
V7-1Z19E9 . . . . . . . . . . . . . . . . . . . 110
V7-2B17D8-201 . . . . . . . . . . . . . . . 111
V7-2B17E9-002 . . . . . . . . . . . . . . . . 111
V7-2B19E9-048 . . . . . . . . . . . . . . . . 111
V7-3S17D8-048 . . . . . . . . . . . . . . . 111
V7-3S17E9-263 . . . . . . . . . . . . . . . . 111
V7-7D17D8-207 . . . . . . . . . . . . . . . 111
V7-9W1AE9-048 . . . . . . . . . . . . . . . 111
Vehicle Controls . . . . . . . . . . . . . . . 175
Hour Meters . . . . . . . . . . . . . . . . . . 176
Indicator Light Strips . . . . . . . . . . 175
Key Switches . . . . . . . . . . . . . . . . 184
Lighting Products . . . . . . . . . . . . . 189
Multi-function Controls . . . . . . . . 175
Other Vehicle Controls . . . . . . . . . . 194
Proportional Retarders . . . . . . . . . 187
Push/Pull Switches . . . . . . . . . . . 185
Shifters . . . . . . . . . . . . . . . . . . . . 186
Throttle Controls . . . . . . . . . . . . . 175
Turn Signals . . . . . . . . . . . . . . . . . 188
Z
ZM10B10A01 . . . . . . . . . . . . . . . . . 107
ZM50E10A01 . . . . . . . . . . . . . . . . . . 107
ZM50E10D01 . . . . . . . . . . . . . . . . . . 108
INDEX
ZM50E10E01 . . . . . . . . . . . . . . . . . . 108
ZM50E70A01 . . . . . . . . . . . . . . . . . . 107
ZM50E70D01 . . . . . . . . . . . . . . . . . . 108
ZM50E70E01 . . . . . . . . . . . . . . . . . . 108
ZM90G20A01 . . . . . . . . . . . . . . . . . 107
ZV10B70A01 . . . . . . . . . . . . . . . . . . 108
ZV50E10A01 . . . . . . . . . . . . . . . . . . 108
ZV50E10B01 . . . . . . . . . . . . . . . . . . 109
ZV50E20A01 . . . . . . . . . . . . . . . . . . 108
ZV50E20F01 . . . . . . . . . . . . . . . . . . 109
ZV50E70C01 . . . . . . . . . . . . . . . . . . 109
ZV50E70F01 . . . . . . . . . . . . . . . . . . 109
ZW10E15CD1 . . . . . . . . . . . . . . . . . 109
ZW10E90FW1 . . . . . . . . . . . . . . . . . 109
ZW50F15AD1 . . . . . . . . . . . . . . . . . 109
ZX10C10A01 . . . . . . . . . . . . . . . . . . 107
ZX40E10C01 . . . . . . . . . . . . . . . . . . 107
ZX40E10E01 . . . . . . . . . . . . . . . . . . 108
ZX40E30A01 . . . . . . . . . . . . . . . . . . 107
ZX40E30C01 . . . . . . . . . . . . . . . . . . 107
ZX40E30E01 . . . . . . . . . . . . . . . . . . 108
210 www.honeywell.com/sensing
Sales and Service
Honeywell serves its customers through a worldwide network of sales offices,
representatives and distributors. For application assistance, current
specifications, pricing or name of the nearest Authorised Distributor or Sales
Representative, contact your local sales office or:
INTERNET: www.honeywell.com/sensing
E-mail: info.sc@honeywell.com
ASIA PACIFIC
Control Products
Asia Pacific Headquarters
Phone: +(65) 6355-2828
FAX: +(65) 6445-3033
Australia
Honeywell Limited
Phone: +(61) 2-9370-4500
FAX: +(61) 2-9370-4525
Toll Free 1300-36-39-36
Toll Free Fax: 1300-36-04-
70
China – PRC - Beijing
Honeywell China Inc.
Phone: +(86-10) 8458-3280
FAX: +(86-10) 8458-3102
China – PRC - Shanghai
Honeywell China Inc.
Phone: (86-21) 6237-0237
FAX: (86-21) 6237-1237
China - Hong Kong S.A.R.
Honeywell Ltd.
Phone: +(852) 2953-6412
FAX: +(852) 2953-6767
Indonesia
Honeywell Indonesia Pte Ltd.
Phone: +(62) 21-535-8833
FAX: +(62) 21-5367 1008
India
TATA Honeywell Ltd.
Phone: +(91) 20 6870 445/
446
FAX: +(91) 20 681 2243/ 687
5992
Japan
Honeywell Inc
Phone: +(81) 3 5440 1425
FAX: +(81) 3 5440 1368
South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799-6167
FAX: +(822) 792-9013
Malaysia
Honeywell Engineering Sdn
Bhd
Phone: +(60-3) 7958-4988
FAX: +(60-3) 7958-8922
New Zealand
Honeywell Limited
Phone: +(64-9) 623-5050
FAX: +(64-9) 623-5060
Toll Free (0800) 202-088
Philippines
Honeywell Systems
(Philippines) Inc.
Phone: +(63-2) 636-1661 /
1662
FAX: +(63-2) 638-4013
Singapore
Honeywell South East Asia
Phone: +(65) 6355-2828
FAX: +(65) 6445-3033
Thailand
Honeywell Systems
(Thailand) Ltd.
Phone: +(662) 693-3099
FAX: +(662) 693-3085
Taiwan R.O.C.
Honeywell Taiwan Ltd.
Phone: +(886-2) 2245-1000
FAX: +(886-2) 2245-3241
EUROPE
Austria
Honeywell Austria GmbH
Phone: +(43) 1 727 80 366/
246
FAX: +(43) 1 727 80 337
Belgium
Honeywell SA/NV
Phone: +(32) 2 728 2522
FAX: +(32) 2 728 2502
Bulgaria
Honeywell EOOD
Phone: +(359) 2 979 00 23
FAX: +(359) 2 979 00 24
Czech Republic
Honeywell spol. s.r.o.
Phone: +(420) 242 442 111
FAX: +(420) 242 442 182
Denmark
Honeywell A/S
Phone: +(45) 39 55 55 55
FAX: +(45) 39 55 55 58
Finland
Honeywell OY
Phone: +(358) 9 3480101
FAX: +(358) 9 34801375
France
Honeywell SA
Phone: +(33) 1 60 19 80 40
FAX: +(33) 1 60 19 81 73
Germany
Honeywell AG
Phone: +(49) 69 8064 444
FAX: +(49) 69 8064 442
Hungary
Honeywell Kft.
Phone: +(361) 451 43 00
FAX: +(361) 451 43 43
Italy
Honeywell S.p.A.
Phone: +(39) 02 92146 450/
456
FAX: +(39) 02 92146 490
The Netherlands
Honeywell B.V.
Phone: +(31) 20 565 69 11
FAX: +(31) 20 565 66 00
Norway
Honeywell A/S
Phone: +(47) 66 76 20 00
FAX: +(47) 66 76 20 90
Poland
Honeywell Sp. zo.o
Phone: +(48) 606 09 64
FAX: +(48) 606 09 01
Portugal
Honeywell Portugal Lda
Phone: +(351 21) 424 50 00
FAX: +(351 21) 424 50 99
Romania
Honeywell Bucharest
Phone: +(40) 21 231 64 37/
38
FAX: +(40) 21 231 6439
Commonwealth of
Independent States (CIS)
Z.A.O. Honeywell
Phone: +(7 095) 796 98 36
FAX: +(7 095) 797 99 06
Slovak Republic
Honeywell s.r.o.
Phone: +(421 2) 58 247 403
FAX: +(421 2) 58 247 415
South Africa (Republic of)
Honeywell Southern Africa
Honeywell S.A. Pty. Ltd
Phone: +(27) 11 695 8000
FAX +(27) 11 805 1504
Spain
Honeywell S.A.
Phone: +(34) 91 313 6100
FAX: +(34) 91 313 6129
Sweden
Honeywell AB
Phone: +(46) 8 775 55 00
FAX: +(46) 8 775 56 00
Switzerland
Honeywell AG
Phone: +(41) 1 855 24 40
FAX: +(41) 1 855 24 45
Turkey
Honeywell Turkey A.S.
Phone: +(90) 216 5756620
FAX: +(90) 216 5756637
Ukraine
Honeywell
Phone: +(380) 44 201 44 74
FAX: +(380) 44 201 44 75
United Kingdom
Honeywell Control Systems
Ltd
Phone: +(44) 1698 481481
FAX: +(44) 1698 481676
Mediterranean & African
Distributors
Honeywell SpA
Phone: +(39) 2 921 46 232
FAX: +(39) 2 921 46 233
Middle East Headquarters
Honeywell Middle East Ltd.
Phone: +(9712) 443 2119
FAX +(9712) 443 2536
NORTH AMERICA
USA/Canada
Honeywell
Sensing and Control
Phone: 1-800-537-6945
1-815-235-6847
FAX: 1-815-235-6545
E-mail:
info.sc@honeywell.com
LATIN AMERICA
Honeywell Latin America
Headquarters
Phone: 1-305-805-8188
FAX: 1-305-883-8257
Argentina
Honeywell S.A.I.C.
Phone: +(54-11) 4383-3627
FAX: +(54-11) 4325-6470
Brazil
Honeywell Do Brasil & Cia
Phone: +(55-11) 4166-1900
FAX: +(55-11) 4166-1901
Chile
Honeywell Chile, S.A.
Phone: +(56-2) 425-8400
FAX: +(56-2) 425-8410
Mexico
Honeywell S.A. de C.V.
Phone: +(52) 55 5081-0200
FAX: +(52) 55 5081-0202
Puerto Rico, Caribbean
Honeywell Inc.
Phone: +(787) 792-7075
FAX: +(787) 792-0053
Venezuela
Honeywell C.A.
Phone: +(58-212) 273-0511
FAX: +(58-212) 273-0599
SALES AND SERVICE
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive Nor th
Minneapolis, MN 55422
www.honeywell.com
000640-1-EN IL50 GLO
July 2006
Copyright © 2006 Honeywell International Inc. All rights reser ved.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell's
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are retur ned to
Honeywell during the period of coverage, Honeywell will
repair or replace, at its option, without charge those items it
finds defective. The forThe for
The forThe for
The foregoing is buyer's sole regoing is buyer's sole r
egoing is buyer's sole regoing is buyer's sole r
egoing is buyer's sole remedy andemedy and
emedy andemedy and
emedy and
is in lieu of all other waris in lieu of all other war
is in lieu of all other waris in lieu of all other war
is in lieu of all other warranties, exprranties, expr
ranties, exprranties, expr
ranties, expressed or implied,essed or implied,
essed or implied,essed or implied,
essed or implied,
including those of merincluding those of mer
including those of merincluding those of mer
including those of merchantability and fitness for achantability and fitness for a
chantability and fitness for achantability and fitness for a
chantability and fitness for a
parpar
parpar
particular purpose. In no event shall Honeywell be liableticular purpose. In no event shall Honeywell be liable
ticular purpose. In no event shall Honeywell be liableticular purpose. In no event shall Honeywell be liable
ticular purpose. In no event shall Honeywell be liable
for consequential, special, or indirfor consequential, special, or indir
for consequential, special, or indirfor consequential, special, or indir
for consequential, special, or indirect damages.ect damages.
ect damages.ect damages.
ect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we