MIL-PRF-39012/3H
w/AMENDMENT 2
Swept frequency VSWR test setup
Item 6: VSWR shall be less than 1.008 +.002 F (F in GHz).
Item 16: VSWR shall be less than 1.008 +.002 F (F in GHz).
Second step of VSWR checkout procedure – VSWR shall be less than 1.012 +.004 F (F in GHz).
Group B inspection – VSWR shall be less than 1.024 +.007 F (F in GHz).
Qualification and group C inspection – VSWR shall not exceed 1.08.
Connector durability: 500 cycles minimum at 12 cycles/minute maximum. The connector shall meet
the mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms maximum.
Initial After environment
Center contact 1.0 1.5
Outer contact (silver) .2 N ot app lic abl e
Outer contact (nickel) .4 Not applicable
Braid to body .05 Not applic abl e
Dielectric withstanding voltage: Method 301 of MIL-STD-202. 3,000 volts rms minimum at sea level for
connectors using other than RG400 and RG142; 1,500 volts rms minimum for connectors using RG400
and RG142.
Vibration, high frequency: Method 204 of MIL-STD-202, test condition B.
Shock: Method 213 of MIL-STD-202, test condition I.
Thermal shock: Method 107 of MIL-STD-202, test condition B, except high temperature shall be
+85°C. High temperature shall be +200°C for connectors using +200°C cables (see table I and III).
Moisture resistance: Method 106 of MIL-STD-202. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona leve l:
Voltage: 500 volts rms minimum
Altitude: 70,000 feet (4.437 kPa).
RF high potential withstanding voltage:
Voltage and frequency: 1,500 volts rms tested at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
11