ECS-MPI4040 Series High Current, High Frequency
Miniature Power Inductors
Technical Data 1704
Effective April 2017
ECS INC. INTERNATIONAL 1105 S. Ridgeview, Olathe KS 66062 ∙913-782-7787 ∙800-237-1041∙ www.ecsxtal.com
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10V , 0.0Adc
4 K-factor: Used to determine B
for core loss (see graph). B
= K * L * DI.
2
I : DC current for an approximate temperature rise of 40°C without core
loss. De-rating is necessary for AC currents. Temperature rise is dependent
upon several factors, including the PCB pad layout, trace thickness and width,
air-flow and proximity to other heat generating components. It is
recommended the part temperature not exceed 125°C under worst case
operating conditions and therefore, the temperature rise should be verified
in the end use application. Irms testing was performed on a 19.05mm long x
6.35mm wide x 0.070mm thick copper trace in still air.
3 I : Peak current for approximately 30% rolloff at +25°C.
Bp-p : (Gauss), K: (K-factor from table), L: (inductance in µH),
DI (peak-to-peak ripple current in amps).
5 Part Number Definition: ECS-MPI4040RX-XXX-R
•
ECS-MPI4040X = product code and size
•
XXX = inductance value in all, “R” = decimal point
- If no
“R”
is present, then third digit equals the number of zeros
•
“-R” suffix = RoHS compliant
† Transient pulse not to exceed 1 millisecond.
†† Maximum operating frequency less than 10MHz, consult factory for
application specific values.