ACDC 15 Watts VCP Series B R A N D xppower.com * Low Cost * Output Voltages from 5 to 24 V * PCB Mounting * Open Frame & Encapsulated Versions * IT & Medical Approvals * Class II Construction * No Load Input Power <0.3 W GREEN*POWER Specification Input General * * * * * * * 90-264 VAC 47-63 Hz 0.5 A max at 90 VAC 40 A max at 240 VAC, cold start at 25 C EN61000-3-2, class A <0.3 W Internal T2.0A/250 V fuse in line Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response * * * * * * * * * Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient * * * * * See table 2% at 50% load No minimum load required 2 s max 100 ms typical 5 ms typical at full load and 115 VAC 0.5% max 2% max, 0-100% load 10% max. deviation, recovery to <1% within 500 s for a 50% step load change at 0.2 A/s See table See table 120-280 %, auto recovery Trip and restart (hiccup mode) 0.2 %/C Input Voltage Input Frequency Input Current Inrush Current Power Factor No Load Input Power Input Protection Output Efficiency Isolation Switching Frequency MTBF * * * * See table 4000 VAC Input to Output 132 kHz typical 250 kHrs to MIL-HDBK-217F at 25 C, GB Environmental Operating Temperature * 0 C to +70 C, derate from 100% load at 50 C to 50% load at 70 C Cooling * Natural convection Operating Humidity * 5-90% RH, non-condensing Storage Temperature * -20 C to +80 C Vibration * 10-300 Hz, 2 g 15 mins/sweep. 30 mins for each of 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity * * * * Radiated Immunity EFT/Burst Surge * * * Conducted Immunity Magnetic Field Dips & Interruptions * * * Safety Approvals * EN55011/22, level B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, 4 kV indirect contact, 8 kV air, Perf Criteria A EN61000-4-3, 3 V/m, Perf Criteria A EN61000-4-4, level 2, Perf Criteria A EN61000-4-5 installation class 3, Perf Criteria A EN61000-4-6, 3 V, Perf Criteria A EN61000-4-8, 1 A/m, Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60950-1, cUL60950-1, IEC60950-1, EN60601-1, cUL60601-1, IEC60601-1 Output Power Output Voltage(2) Output Current Ripple & Noise(1) OVP Setting(3) Efficiency(5) Model Number(4) 10 W 5.0 V 2.00 A 100 mV 10.0 V 74% VCP15US05^ 15 W 12.0 V 1.25 A 100 mV 20.0 V 82% VCP15US12^ 15 W 15.0 V 0.90 A 150 mV 25.0 V 83% VCP15US15 15 W 24.0 V 0.63 A 200 mV 35.0 V 84% VCP15US24^ Notes 1. Measured at DC output connector using 20 MHz bandwidth and 0.1 F ceramic capacitor in parallel with 10 F electrolytic capacitor placed at connector terminals. 2. Other voltages between 5.0 V and 24 V are available, consult sales for details. 3. Typical trip point. 4. For encapsulated versions, add suffix `-E' to the model number e.g VCP15US24-E. 5. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input. Available from Farnell & element14. See page 28. ^ Available from Newark. See page 28. Mechanical Details Encapsulated Version (E) 0.677 (17.2) Open Frame Version 2.55 (65.0) 1.197 (30.4) 0.484 (12.3) 1.197 (30.4) 3 1 TOP VIEW 1.65 (42.0) TOP VIEW 4 5 0.85 (21.50) 1.24 (31.40) o 0.04 (o1.00) 0.18 (4.50) 0.15 (3.80) o 0.070 (o1.80) o 0.04 (o1.00) 1.205 (30.6) 1.11 (28.2) 1.27 (32.5) 1.205 (30.6) 0.819 (20.8) 0.15 (3.80) 0.484 (12.3) 0.465 (11.8) 0.626 (15.9) 5 0.819 (20.8) 0.06 (1.60) 1.49 (38) 0.555 (14.1) 0.67 (17.0) 0.465 (11.8) 0.677 (17.2) 0.626 (15.9) 4 2 1 0.67 (17.0) 2 3 0.555 (14.1) 1.209 (30.7) 2.72 (69.0) 1.209 (30.7) Pin Designation 1 Live 2 Neutral 3 No connection 4 Output -VE 5 Output +VE Notes 1. All dimensions are in inches (mm). 2. Weight: Open frame versions: 0.09 lbs (40 g) approx. Encapsulated versions: 0.22 lbs (100 g) approx. 3. Tolerance: x.xx = 0.04 (x.x = 0.1); x.xxx = 0.2 (x.xx = 0.5) 04-Oct-11 ACDC VCP15 Models and Ratings